ML20207M554
| ML20207M554 | |
| Person / Time | |
|---|---|
| Site: | Trojan File:Portland General Electric icon.png |
| Issue date: | 01/09/1987 |
| From: | Lindblad W PORTLAND GENERAL ELECTRIC CO. |
| To: | NRC OFFICE OF ADMINISTRATION (ADM) |
| Shared Package | |
| ML20207M561 | List: |
| References | |
| TAC-60095, NUDOCS 8701130219 | |
| Download: ML20207M554 (2) | |
Text
PORTLAND GENERAL ELEcTHic COMPANY 121 S. W. S ALM O N STREET WILLIAM J. LIN DBLAo PO RTLA N o. O R EG O N 97204 1503)226-8875 January 9, 1987 Trojan Nuclear Plant Docket 50-344 License NPF-1 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington DC 20555
Dear Sir:
License Change Application 134. Revision 1 Attached are three signed originals and 40 conformed copies of Revision 1 to License Change Application (LCA) 134 requesting amendment of Operating License NPF-1.
LCA 134 proposes to revise the minimum water level required to be maintained in the condensate storage tank. The original change application included an interim water level to be maintained until modifications to the Auxiliary Fecdwater System were completed. With modifications complete, Revision 1 removes that provision and incorporates the final revised minimum level.
Also attached is one signed copy of a Certificate of Service for LCA 134 Revision 1 to the chief executive of the county in which the facility is located and the Director of the State of Oregon, Department of Energy.
Sincerely, Attachments c:
Mr. John B. Martin Regional Administrator, Region V U.S. Nuclear Regulatory Commission Mr. Gary Kellund Resident Inspector Trojan Nuclear Plant Mr. David Kish, Acting Director State of Oregon Department of Energy Mr. Michael J. Sykes Chairman of county Commissioners o*g G701130219 870109 l
PDR ADOCK 05000344 p
PDR _
l UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION In the Matter of
)
)
PORTLAND GENERAL ELECTRIC COMPANY,
)
Docket 50-344 THE CITY OF EUGENE, OREGON, AND
)
Operating License NPF-1 PACIFIC POWER & LIGHT COMPANY
)
)
(TROJAN NUCLEAR PLANI)
)
CERTIFICATE OF SERVICE I hereby certify that copies of License Change Application 134, Revision 1 to the Operating License for Trojan Nuclear Plant, dated January 9, 1987, have been served on the following by hand delivery or by deposit in the United States mail, first class, this 9th day of January 1987:
Mr. David Kish, Acting Director State of Oregon Department of Energy 625 Marion St NE Salem OR 97310 Mr. Michael J. Sykes Chairman of County Commissioners Columbia County Courthouse St. Helens OR 97051
~G.
Zimmerman, Manager '
I l
Nuc e r Regulation Branch Nuc e Safety & Regulation Subscribed and sworn to before me this 9th day of January 1987.
hd o
Notary Public of Ore gn l
My Commission Expires:
em mf [ /((9 6
l
-.