Forwards Revised Pages for License Change Application 124 to License NPF-1,changing Table 3.6-1 to Add Seven of Eight Valves Previously Deleted from Table,For Review & Approval. Valve MO-8106 Should Remain Deleted from Table
ML20207D082
Person / Time
Site: Trojan File:Portland General Electric icon.png
Issue date: 12/22/1986
From: Lindblad W
PORTLAND GENERAL ELECTRIC CO.
To: Varga S
Office of Nuclear Reactor Regulation
References
TAC-59562, NUDOCS 8612300318
Download: ML20207D082 (3)


Text

.

L PoHTLANn GENERAL ELEcTHic Coxiwny 121 S. W. S ALM O N STREET wlLLIAM J. LINOBLAD PORTLAN D, OR EGO N 97204 (sosi aze-se7s December 22, 1986 Trojan Nuclear Plant Docket 50-344 License NPF-1 Director of Nuclear Reactor Regulation ATTN: Mr. Steven A. Varga Director, PWR-A Project Directorate No. 3 U.S. Nuclear Regulatory Commission Washington DC 20555

Dear Mr. Varga:

License Change Application 124 Containment Isolation Valves Pursuant to discussions, attached are revised pages for LCA 124. This change adds seven of eight valves back onto Table 3.6-1 that were proposed to be deleted in LCA 124. These revised pages are submitted to expedite NRC review and approval of LCA 124. The licensing criteria for Containment penetrations at the Trojan Nuclear Plant will be reexamined in light of current criteria in their specific application to these seven valves. A separate LCA to address only these seven valves may be submitted pending the results of this examination.

As discussed, the eighth valve (MO-8106 - CVCS charging) is clearly not a containment isolation valve. This is because check valve 8381 is available as an inner barrier and valve MO-8105 is available as an outer barrier for the charging line. Therefore, it is proposed that valve MO-8106 remain deleted from TTS Table 3.6-1.

Sincerely, e . e 2]d G Attachment c: Mr. David Kish, Acting Director State of Oregon Department of Energy Mr. Michael J. Sykes Chairman of County Commissioners 8612300318 861222 PDR ADOCK 05000344 P PDR hg0 {

M

a 4

4 TABLE 3.6-1 8

b CONTAINMENT ISOLATION VALVES Y

E

i TESTABLE DURING ISOLATION TIME

_. VALVE NUMBER FUNCTION PLANT OPERATION- (seconds)

B. Automatic Containment Ventilation Isolation Valves (Continued)

M0 10011 *** Hydrogen vent exhaust - outside yes 5
MO 10012*** Hydrogen vent exhaust - outside yes 5 i

M0 10007*** Hydrogen vent supply - inside yes 5 M0 10008*** Hydrogen vent supply - inside yes 5 M0 10009*** Hydrogen vent exhaust - inside yes 5 M0 10010*** Hydrogen vent exhaust - inside yes 5 C. Non-Automatic Power'0perated Isolation Valves 4

MO 3291# CCW train "A" supply - outside no N.A.

Mi MO 3292# CCW train "A" discharge - outside no N.A.

M0 3346# CCW train "B" supply - outside no N.A.

i i' MO 3290# CCW train "B" discharge - outside no N.A.

E$ M0 2053A# Containment Spray Pump A

discharge - outside yes N.A.

M0 2053B# Containment Spray Pump B discharge - outside yes N.A.

MO 8702#4 RHR normal suction inside no N.A. l MO 870l#4 RHR normal suction inside no N.A.

CV 8825# RHR hot leg recirculation - inside no N.A.

MO 8703# RHR hot leg recirculation - outside no N.A.

MO 8835# SIS discharge line - outside no N.A.

(cold leg)

> M0 8809A# RHR pump "A" discharge - outside no N.A.

2 MO 8809B# RHR pump "B" discharge - outside no N.A. o > r-1 MD 2069A# Sump Recirculation Train "A" -

yes N.A. $%S 8 inside * $ --

A M0 20698# Sump Recirculation Train "B" -

2 [ S$ '

g: inside yes N.A., o, g

, N --

1

o

{

TABLE 3.6-1 i E CONTAINMENT ISOLATION VALVES E_

~

TESTABLE DURING ISOLATION TIME VALVE NUMBER FUNCTION PLANT OPERATION (seconds) i C. Non-Automatic Power Operated Isolation Valves (Continued) i l M0 2052A SIS Recirculation Train "A" - outside yes N.A.

MO 8811A SIS Recirculation Train "A" - outside yes N.A.

j M0 20528 SIS Recirculation Train "B" - outside yes N.A.

MO 8811B SIS Recirculation Train "B" - outside yes N.A.

j CV 8843# BIT Discharge - inside no N.A.

? MO 890?A# SIS discharge Train "A" - outside no N.A.

MO 8802B# SIS discharge Train "B" - outside no N.A.

i CV 8881# SIS discharge Train "A" - inside yes N.A.

CV 8824# SIS discharge Train "B" - inside yes N.A.

D. Manual Valves 8090A* (RCS) Deadweight Tester - outside N.A. N.A.

, m 8090B* (RCS) Deadweight Tester - outside N.A. N.A.

E

~

SF080 Refueling cavity recirculation -

inside N.A. N.A.

SF046 Refueling cavity recirculation -

1 outside N.A. N.A.

{ SF073 Refueling cavity drain - inside N.A. N.A.

SF074 Refueling cavity drain - outside N.A. N.A.

i SF063 Refueling cavity skiming - inside N.A. N.A.

SF062 Refueling cavity skiming - outside N.A. N.A.

MD059* Demin. water washdown - outside N.A. N.A.

10610A ILRT Instrument Line - outside N.A. N.A. ?RE l g 10610B ILRT Instrument Line - inside N.A. N.A. %g>

l g 10611A ILRT Instrument Line - outside N.A. N.A. 9.~

2 c. 10611B ILRT Instrument Line - inside N.A. N.A. "R" i

l a

LD00l*

LD003*

45-ft airlock test line - outside 45-ft airlock test line - outside N.A.

N.A.

N.A.

N.A.

O w _.

E

! z g ,

s