' Onnrnonuralth 14hwn Gimpany Ily ron Generating $tation 4 60 North Grrman Church Road Ihron,11. (>1010 979 4 Tel HI4-234 5 4 4I April 28,1999 LTR:

BYRON 99-0042 FILE:

2.12.1522 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D.C. 20555 Byron Station, Units 1 and 2 Facility Operating License Nos. NPF 37 and 66 NRC Docket Nos. 50-454 and 50-455

SUBJECT:

1998 Annual Radioactive Effluent Release Report Enclosed is the Annual Radioactive Effluent Release Report for Byron Station. This report is being submitted in accordance with 10CFR50.36a and includes a summary of radiological liquid and gaseous effluents and solid waste released from the site from January 1998 through December 1998.

If you have any questions regarding this information, please contact Mr. B.J. Adams, Regulatory Assurance Manager, at (815) 234-5441, extension 2280.

Respectfully, i

d ~ /B p William Levis Site Vice President Byron Station

[

WL/SDR/kh Attachment

i. 9 0'j, cc:

Regional Administrator-NRC Region 111 NRC Senior Resident inspector-Byron Station f*

8 R

(rd99byttrs@90042. doc)

A l'nicom Company

I l

1 l

BYRON NUCLEAR POWER STATION UNIT 1/2 DOCKET NUMBER STN40-454/455 RADIOACTIVE EFFLUENT RELEASE REPORT l

Januarv. M THROUGH December,19fd SupplementalInformation 1.

Regulatory Limits a.

Fission and activation gases:

Tech Spec Whole Body = 500 mrem / year Skin = 3000 mrem / year 10CFR50 Gamma = 5 mrad / quarter; 10 mrad / year Beta = 10 mrad / quarter; 20 mradlyear b.

todine: (summed with particulate, see below) c.

Particulates with half-lives > 8 days:

Tech Spec Organ = 1500 mrem / year 10CFR50 Organ = 7.5 mrem / quarter; 15 mrem / year d.

Liquid effluents:

10CFR50 Whole Body = 1.5 mrem / quarter; 3 mrem / year Organ = 5 mrem / quarter; 10 mrem / year e.

Total Effective Dose Equivalent 10CFR20 TEDE = 100 mrem / year 1

2.

Maximum Permissible Concentration

)

a.

Fission and Activation Gases: 10CFR20 Appendix B Table 2 b.

lodine: 10CFR20 Appendix B Table 2 c.

Particulates: 10CFR20 Appendix B Table 2 d.

Liquid Effluents: 10CFR20 Appendix B Table 2 3.

Average Energy: This item is not applicable. Release rates are calculated using an isotopic mix rather than average energy.

4.

Measurements and Approximations of Total Radioactivity a.

Fission and Activation Gases: Prior to release, the isotopic content is determined. Released activity is calculated using volume of release, which is determined by the change in tank or containment pressure. Additional methods of calculation utilize historical data and assign an isotopic mix which is representative of normal vent stack isotopics.

{

Report Page 1 of 31 (pa\\99byltrs\\990c42. doc)

I

e BYRON NUCLEAR POWER STATION UNIT 1/2 DOCKET NUMBER STN-50-454/455 RADIOACTIVE EFFLUENT RELEASE REPORT Januarv. R THROUGH Dece'Bhtt 1998 Supplemental Information (continued) b.

Particulate, Tritium and lodine sampling media for the plant vent stacks are collected and Isotopically analyzed weekly for the plant vent stacks.

c.

Liquids effluents: Batch releases are isotopically analyzed prior to release. Total release activity is calculated using volume of release. Total tntium activity released is calculated from the highest of a monthly circulating water blowdown composite activity or a sum of the input composite activities.

d.

Analysis results which are !cs6 than the lower kmit of detection (<LLD) are reported in units of Ci/ml unless otherwise noted. All LLD values are listed in Attachment A.

5.

Batch Releases:

a.

Liquid:

1.

Number of batch releases = 258 2.

Total time period for batch releases = 18,063 minutes 3.

Maximum time period for a batch release = 331 minutes 4.

Average time period for a batch release = 70 minutes 5.

Minimum time period for a batch release = 7 minutes 6.

Average stream flow during periods of release of effluent into a flowing stream

= 209 cms, based on information from the National Weather Service or Army Corps of Engineers for the Rock River, b

Gaseous:

1.

Number of batch releases = 295 2.

Total time period for batch releases = 136,990 minutes 3.

Maximum time period for a batch release = 40,870 minutes 4.

Average time period for tetch releases = 464.4 minutes 5.

Minimum time period for a batch release = 1 minute 6.

Abnormal Releases:

a.

Liquid - None b.

Gaseous Steam Generator Replacement Project related ground level release data is listed in Attachment B. Dose attributed to these releases is included in dose calculations.

c.

Gaseous - Unit 2 Refuel Outage related ground level release data is listed in Attachment C. Dose I

attributed to these releases is included in dose calculations.

Report Page 2 of 31 (p \\99byltra\\990042. doc)

F Approved 5/13/97 FACSIMILE BRP 6100-6T1 Revision 4 BYRON NUCLEAR POWER STATION UNIT 1 DOCKET NUMBER STN-50-454 RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY,1998 THROUGH DECEMBER,1998 GASEOUS EFFLUENTS - SUMMATION OF ALL RELEASES l

UNITS l 1st Quarter l 2nd Quarter l 3rd Quarter l 4th Quarter l A. FISSION AND ACTIVATION GAS RELEASES

1. Total Release Activity:

Ci 1.09E+00 9.12E-01 1.25E-01 2.02E-01

2. Maximum Rolsase Rate for Quarter:

uCi/sec 6.96E-01 5.13E+00 9.06E+01 7.59E+00

3. % of imp. Tech. Spec. Limits *
a. Whole Body (500 mrem /yr):

0.00 0.00 0.00 0.00

b. Skin (3000 mrem /yr):

0.00 0.00 0.00 0.00

4. % of 10CFR50 Limits
a. Gamma Quarterly (5 mrad):

0.00 0.00 0.00 0.00

b. Beta Quarterly (10 mrad):

0.00 0.00 0.00 0.00

c. Gamma Annual (10 mrad):

0.00 0.00 0.00 0.00

d. Beta Annual (20 mrad):

0.00 0.00 0.00 0.00 B. IODINE RELEASES "

1. Totall-131 Activity:

Ci

< LLD

< LLD

< LLD

< LLD

2. Average 1-131 Release Rate:

uCi/sec 0.00E+00 0.00E+00 0.00E+00 0.00E+00 C. PARTICULATE (>8 day half-life) RELEASES "

1. Total Particulate Activity:

Ci 1.93E-06 1.46E-~06 3.89E-07

<LLD

2. Average Particulate Release Rate:

uCi/sec 2.48E-07 1.86E-07 4.89E-08 0.00E+00

3. Gross Alpha Activity for Quarter:

Ci

< LLD

< LLD

< LLD

< LLD D. TRITIUM RELEASES "

1. Total Tritium Activity:

Ci 5.70E-02 6.82E-02 6.82E-02 1.21E-01

2. Average Tritium Release Rate:

uCi/sec 7.33E-03 8.67E-03 8.58E-03 1.52E-02

  • % of Imp. Tech. Spec. limits is based on the maximum release rate for the period considered.
    • lodine, particulate, and tritium are expressed as a total limit. See Step E.

I (9916SS/XLS/051397)

Report Page 3_of 31

i Appr;ved 5/13/97 FACSIMILE BRP 6100-6T1 R:: vision 4 BYRON NUCLEAR POVER STATION UNIT 1 DOCKET NUMBER STN-50-454 4

RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY,1998 THROUGH DECEMBER,1998 GASEOUS EFFLUENTS - SUMMATION OF ALL RELEASES (CONT.)

l UNITS l 1st Quarter l 2nd Quarter l 3rd Quarter l 4th Quarter l 1

E. TOTAL OF IODINE, PARTICULATE (>8 day half-life), AND TRITIUM RELEASES

1. Total Activity:

l Ci l 5.70E-02 l 6.82E-02 l 6.82E-02 l 1.21 E-01 l

2. % of imp. Tech. Spec. Limits
a. Any Organ (1500 mrem /yr):

l l

0.00 l

0.00 l

0.00 l

0.00 l

3. % of 10CFR50 Limit
a. Quarterly Any Organ l

l 0.00 l

0.00 l

0.00 l

0.00 l

(7.5 mrem):

b. Annual Any Organ l

l 0.00 l

0.00 l

0.00 l

0.00 l

(15 mrem):

GASEOUS EFFLUENTS - VENT STACK RELEASES - BATCH MODE F. FISSION AND ACTIVATION GAS RELEASES ArJ1:

Ci 2.97E-03 2.64E-03

<LLD

<LL D Kr-85:

Ci

<LLD

<LLD

<LLD

<LLD Kr-85m:

Ci 1.01 E-04

<LLD

<LLD

<LLD Kr-87:

Ci

<LLD

<LLD

<LLD

<LLD Kr-88:

Ci

<LLD

<LLD

<LLD

<LLD Xe-131m:

Ci

<LLD

<LLD

<LLD

<LLD Xe-133:

Ci 5.72E-02 9.69E-02 4.53E-03 3.92E-02 Xe-133m:

Ci 3.30E-04 2.24E-03

<LLD

<LLD Xe-135:

Ci 7.18E-03 5.87E-03

<LLD

<LLD Xe-138:

Ci

<LLD

<LLD

<LLD

<LLD Xe-125:

Ci

<LLD

<LLD 1.08E-03

<LLD l

l

\\

(9916SS/XLS/051397)

Report Page.4_of 31 i

I

r~

4pproved 5/13/97 FACSIMILE BRP 6100-6T1 Rsvision 4 l

l l

BYRON NUCLEAR POWER STATION UNIT 1 DOCKET NUMBER STN-50-454 RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY,1998 THROUGH DECEMBER,1998 GASEOUS EFFLUENTS - VENT STACK RFI FASES - BATCH MODE (CONT.)

l UNITS l 1st Quarter l 2nd Quarter l 3rd Quarter l 4th Quarter l G. IODINE RELEASES l-131:

Ci j

l 133:

Ci l

1-135:

Ci

  • Value reported as CONTINUOUS RELEASE MODE.

H. PARTICULATE (>8 day half-life) RELEASES

)

Sr-89:

Ci Sr-90:

Ci

  • Value reported as CONTINUOUS RELEASE MODE.

GASEOUS EFFLUENTS - VENT STACK RELEASES - CONTINUOUS MODE

1. FISSION AND ACTIVATION GAS RELEASES Xe-133:

Cl 1.02E+00 8.04E-01

<LLD

<LLD Xe-133m:

Ci

<LLD

<LLD 3.81E-03

<LLD Xe-131m:

Ci

<LLD

<LLD 1.16E-01

<LLD Kr-85m:

Ci

<LLD

<LLD

<LLD 6.25E-02 Xe-135:

Ci

<LLD

<LLD

<LLD 5.00E-03 i

Xe-138:

Ci

<LLD

<LLD

<LLD 9.50E-02 i

(9916SS/XLS/051397)

Report Page 5_of 31

1 f

Approved 5/13/97 FACSIMILE BRP 6100-6T1 Revision 4 BYRON NUCLEAR POWER STATION UNIT 1 DOCKET NUMBER STN-50-454 RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY,1998 THROUGH DECEMBER,1998 i

GASEOUS EFFLUENTS - VENT STACK RELEASES - CONTINUOUS MODE (CONT.)

{

l UNITS l 1st Quarter l 2nd Quarter j 3rd Quarter l 4th Quarter l J. LODINE RELEASES l-131:

Ci

<LLD

<LLD

<LLD

<LLD l-133:

Ci

<LLD

<LLD

<LLD

<LLD l-135:

Ci

<LLD

<LLD

<LLD

<LLD K. PARTICULATE (>8 day half-life) RELEASES Sr-89:

Ci

<LLD

<LLD

<LLD

<LLD Sr-90:

Ci

<LLD

<LLD

<LLD

<LLD Co-58:

Ci

<LLD 1.46E-06

<LLD

<LLD Co-60:

Ci 1.93E-06

<LLD

<LLD

<LLD Br-82 Ci

<LLD

<LLD 3.89E-07

<LLD LIQUID EFFLUENTS - Suuu ATION OF ALL RELFASES L. FISSION AND ACTIVATION PRODUCT RELEASES

1. Total Activity Released:

Ci 8.80E-02 1.20E-01 3.54E-02 7.26E-02

2. Average Concentration uCi/ml 3.79E-08 4.54E-08 1.30E-08 2.52E-08 Released For Quarter
3. % of 10CFR50 Limits
a. Quarterly Whole Body l

l 0.03 l

0.09 l

0.03 l

0.04 l

(1.5 mrem):

b. Quarterly Any Organ l

l 0.05 l

0.04 l

0.01 l

0.05 l

(5.0 mrem):

c. AnnualWhole Body l

l 0.02 l

0.05 l

0.02 l

0.02 l

(3.0 mrem):

d. Annual Any Organ l

l 0.03 l

0.02 l

0.01 l

0.03 l

(10.0 mrem):

(9916SS/XLS/051397)

Report Page fi_of 31

Approved 5/13/97 FACSIMILE BRP 6100-6T1 Revision 4 BYRON NUCLEAR POWER STATION UNIT 1 DOCKET NUMBER STN-50-454 RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY,1998 THROUGH DECEMBER,1998 LIQUID t FFLUENTS - SU""""ATION OF Al t RFI FASES (CONT.)

l UNITS l 1st Quarter l 2nd Quarter l 3rd Quarter l 4th Quarter l M. TRITIUM

1. Total Activity Released:

Ci 1.36E+02 7.95E+ 01 1.50E+02 2.855+02

2. Average Concentration uCi/mi 5.84E-05 3.01 E-05 5.50E-05 9.89E-05 Released For Quarter.
3. % of ITS Limit l

l 0.58 l

0.30 l

0.55 l

0.99 l

(1.00E-2 uCi/ml):

N. DISSOLVED NOBLE GASES

1. Total Activity Released:

Ci 2.97E-02 3.61E-02 1.55E-02 1.45E-02

2. Average Concentration

_ uCi/ml 1.28E-08 1.37E-08 5.70E-09 5.04E-09 Released For Quarter:

3. % of Tech. Regt. Manual Limit l

l 6.39E-03 l 6.83E-03 l 2.85E-03 l 2.52E-03 l (2.00E-4 uCi/mi):

O. GROSS ALPHA

1. Total Activity Released:

Ci

<LLD

<LLD

<LLD

<LLD

2. Average Concentration uCi/ml

<LLD

<LLD

<LLD

<LLD Released For Quarter:

P. VOLUME OF WASTE l

liters l 3.42E+06 l 3.94E+06 l 1.97E+06 l 1.23E+06 l RELEASED PER UNIT:

Q. VOLUME OF DILUTION l

liters l 2.32E+09 l 2.64E+09 l 2.72E+09 l 2.89E+09 l WATER PER UNIT:

LIQUID EFFLUENTS - CQWTINUOUS MODE R. LIQUID EFFLUENTS Fe-55:

Ci Sr-89:

Ci Sr-90:

Ci

  • Value reported as LIQUID EFFLUENTS - BATCH MODE (9916SS/XLS/051397)

Report Page Z_of 31

l Approved 5/13/97 FACSIMILE BRP 6100-6T1 Rcvision 4 BYRON NUCLEAR POWER STATION UNIT 1 DOCKET NUMBER STN-50-454 RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY,1998 THROUGH DECEMBER,1998 LIQUID EFFLUENTS - BATCH MODE l

l UNITS l 1st Quarter l 2nd Ov9rter l 3rd Quarter l 4th Quarter l

{

S. LIQUID EFFLUENTS Fe-55:

C6 6.42E-03 6.67E-03 1.28E-03 6.80E-03 Sr-89:

Ci

<LLD

<LLD

<LLD

<LLD Sr-90:

Ci

<LLD

<LLD

<LLD

<LLD H-3:

Ci 1.36E+02 7.95E+01 1.50E+02 2.85E+C2 Ar-41:

Ci 3.53E-04 5.68E-04

<LLD 6.53E-05 Cr-51:

Ci 8.97E-04 5.42E-03

<LLD 5.31E-04 Mn-54:

Cl 3.57E-04 4.18E-04 1.30E-04 1.88E-03 Fe-59:

Ci 3.07E-04 1.26E-03 1.75E-05 5.15E-05 Co-57:

Ci 3.47E-05 6.17E-05 4.44E-05 3.27E-04 Co-58:

Ci 1.34E-02 3.50E-02 1.05E-02 1.44E-02 Co-60:

Cl 1.02E-02 7.97E-03 4.23E-03 2.58E-02 Zn-65:

Ci

<LLD 5.16E-06

<LLD 4.08E-04 Kr-85:

Cl 1.98E-02 3.48E-02 1.54E-02 1.43E-02 Kr-85m:

Ci 5.89E-06

<LLD

<LLD

<LLD Kr-87:

Ci

<LLD

<LLD

<LLD

<LLD Kr-88:

Ci

<LLD

<LLD

<LLD

<LLD Sr-92:

Ci 1.28E-03 9.24E-06

<LLD 1.73E-04 Nb-95:

Ci 9.09E-04 5.23E-04 2.61 E-05 8.52E-04 Zr-95:

Ci 2.15E-05 2.19E-04

<LLD 3.46E-04 Zr-97:

Ci 9.30E-05

<LLD

<LLD 4.66E-06 Mo-99:

Ci

<LLD

<LLD

<LLD

<LLD Tc-99m:

Ci

<LLD

<LLD

<LLD

<LLD Tc-104:

Ci

<LLD

<LLD

<LLD

<LLD Ag-110m:

Ci 4.33E-03 1.25E-04 7.23E-06 5.63E-04 Sn-113:

Ci

<LLD 5.43F-06

<LLD 2.94E-05 Te-121m:

Ci

<LLD

<LLD

<LLD

<LLD Te-123m:

Ci 5.49E-03 1.78E-03 1.57E-04 7.44E-05 Te-125m:

Ci 3.78E-02 2.24E-02 1.46E-02 1.90E-02 Sb-122:

Ci 2.47E-06 1.49E-03

<LLD

<LLD Sb-124:

Ci 2.29E-03 7.87E-03 5.26E-04 4.02E-05 Sb-125:

Ci 3.69E-03 2.69E-02 3.83E-03 1.41 E-03 Sb-126:

Ci

<LLD 3.25E-04

<LLD 1.45E-06 (9916SS/XLSiO51397)

Report Page B of 31

Approv:d 5/13/97 FACSIMILE BRP 6100-6T1 Rsvision 4 BYRON NUCLEAR POWER STATION UNIT 1 DOCKET NUMBER STN-50-454 RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY,1998 THROUGH DECEMBER,1998 4

LIQUID EFFLUENTS - BATCH MODE (CONT.)

l UNITS l 1stQuarter l 2nd Quarter l 3rd Quarter l 4th Quarter l S. LIQUID EFFLUENTS (CONT.)

1-131:

Ci

<LLD 1.34E-05

<LLD 8.12E-07 l-132:

Ci

<LLD

<LLD

<LLD

<LLD l-133:

Ci 2.05E-06

<LLD

<LLD

<LLD l-135:

Ci

<LLD

<LLD

<LLD

<LLD Xe-131m:

Ci

<LLD

<LLD

<LLD

<LLD Xe-133:

Ci 8.31E-03 7.61E-04 9.58E-05 1.79E-04 Xe-133m:

Ci 1.34E-04

<LLD

<LLD

<LLD Xe-135:

Ci 1.05E-03 2.31E-06

<LLD

<LLD Xe-135m:

Ci

<LLD

<LLD

<LLD

<LLD Xo-138:

Ci

<LLD

<LLD

<LLD

<LLD Cs-134:

Ci 1.47E-04 1.15E-03 1.64E-04

<LLD Cs-137:

Ci 2.26E-04 2.09E-04 2.12E-05

<LLD Ba-140:

Ci

<LLD

<LLD

<LLD

<LLD La-140:

Ci

<LLD

<LLD

<LLD

<LLD Ce-141:

Ci

<LLD

<LLD

<LLD

<LLD Ce-144:

Ci

<LLD

<LLD

<LLD

<LLD Y-92:

Ci 6.83E-05

<LLD

<LLD

<LLD Na-24:

Ci 3.16E-06 3.50E-05

<LLD

<LLD Br-82:

Ci

<LLD 1.70E-06

<LLD

<LLD Te-132:

Ci

<LLD 1.34E-05 3.75E-06

<LLD i

l T.10CFR20 PUBLIC TEDE COMPLIANCE

1. % OF 10CFR20 TEDE LIMIT l

l 0.00 l

0.00 l

0.00 l

0.00 l

(100 mrem /yr):

(9916SS/XLS/051397)

Report Page 9_of 31

4PProved 5/13/97 FAC MILE BRP 6100-6T1 Rsvision 4 BYRON NUCLEAR POWER STATION UNIT 2 DOCKET NUMBER STN-50-455 RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY,1998 THROUGH DECEMBER,1998 GASEOUS EFFLUENTS - SU^^^^tTION OF At i RFI FASES l

UNITS l 1st Quarter l 2nd Quarter l 3rd Quarter l 4th Quarter l A. FISSION AND ACTIVATION GAS RELEASES

1. Total Release Activity:

Ci 1.11E+00 9.50E-01 1.67E-01 1.86E-01

2. Maximum Release Rate for Quarter:

uCi/sec 7.34E-01 5.13E+00 5.13E+02 2.16E+02

3. % of Imp. Tech. Spec. Limits:*
a. Whole Body (500 mrem /yr):

0.00 0.00 0.00 0.00

b. Skin (3000 mremlyr):

0.00 0.00 0.00 0.00

4. % of 10CFR50 Limits
a. Gamma Quarterly (5 mrad):

0.00 0.00 0.00 0.00

b. Beta Quarterly (10 mrad):

0.00 0.00 0.00 0.00

c. Gamma Annual (10 mrad):

0.00 0.00 0.00 0.00

d. Beta Annual (20 mrad):

0.00 0.00 0.00 0.00 B. IODINE RELEASES "

1.TotalI-131 Activity:

Ci

<LLD 4.23E-06

<LLD

<LLD

2. Average 1-131 Release Rate:

uCi/sec 0.00E+00 5.38E-07 0.00E+00 0.00E+00 C. PARTICULATE (>8 oay half-life) RELEASES "

1, Total Particulate Activity:

Ci 2.81 E-03 7.48E-06

<LLD 1.30E-06

2. Average Particulate Release Rate:

uCi/sec 3.61 E-04 9.51 E-07 0.00E+00 1.64E-07

3. Gross Alpha Activity for Quarter:

Ci

<LLD

<LLD

<LLD

<LLD D. TRITIUM RELEASES "

1. Total Tritium Activity:

Ci 1.58E-01 1.31 E-01 1.83E-01 2.86E-01

2. Average Tritium Release Rate:

uCi/sec 2.04E-02 1.66E-02 2.30E-02 3.60E-02

  • % of imp. Tech. Spec. limits is based on the maximum release rate for the period considered.
    • lodine, particulate, and tritium are expressed as a totallimit. See Step E.

(9916SS/XLS/051397)

Report Page10_of 31 i

1

. Apprc;v;d 6/13/97 FACSIMILE BRP 6100-6T1 R: vision 4 BYRON NUCLEAR POWER STATION UNIT 2 DOCKET NUMBER STN-50-455 RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY,1998 THROUGH DECEMBER,1998 GASEOUS EFFLUENTS - SUMMATION OF At i RFI FASES (CONT 3 l

UNITS l 1st Quarter l 2nd Quarter l 3rd Quarter l 4th Quarter l E. TOTAL OF IODINE, PARTICULATE (>8 day half-life), AND TRITIUM RELEASES

1. Total Activity:

l C6 l 1.61E-01 l 1.31E-01 l 1.83E-01 l 2.86E-01 l

2 % of imp. Tech. Spec. Limits

a. Any Organ (1500 mrem /yr):

l l

0.00 l

0.00 l

0.00 l

0.00 l

3. % of 10CFR50 Limit
a. Quarterly Any Organ l

l 0.00 l

0.00 l

0.00 l

0.00 l

(7.5 mrem):

a. Annual Any Organ l

l 0.00 l

0.00 l

0.00 l

0.00 l

(15 mrem):

GASEOUS EFFLUENTS - VENT STACK RFt.FASES - BATCH MODE F. FISSION AND ACTIVATION GAS RELEASES Ar-41:

Ci 1.62E-02 3.30E-03 4.53E-03

<LLD Kr-85:

Ci

<LLD

<LLD

<LLD

<LLD Kr-85m:

Cl 1.01 E-04

<LLD

<LLD

<LLD Kr-87:

Ci

<LLD

<LLD

<LLD

<LLD i

Kr-88:

Ci 4.38E-03 1.22E-02

<LLD

<LLD Xe-131m:

Ci

<LLD

<LLD

<LLD

<LLD Xe-133:

Ci 5.72E-02 1.17E-01 4.18E-02 2.33E-02 Xe-133m:

Ci 3.30E-04 7.46E-03

<LLD

<LLD Xe-135:

Ci 7.18E-03 5.87E-03 3.72E-04

<LLD Xe-138:

Ci

<LLD

<LLD

<LLD

<LLD 4

(9916SS/XLS/051397)

Report Page1Lof 31

Approved 5/13/97 FACSIMILE BRP 6100-6T1 Revision 4 BYRON NUCLEAR POWER STATION UNIT 2 DOCKET NUMBER STN-50-455 RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY,1998 THROUGH DECEMBER,1998 GASEOUS EFFLUENTS - VENT STACK RFI FASES - BATCH MODE (CONT 3 l

UNITS l 1st Quarter l 2nd Quarter l 3rd Quarter l 4th Quarter l G. IODINE RELEASES l-131:

Ci l-133:

Ci l-135:

Ci

  • Value reported as CONTINUOUS RELEASE MODE.

H. PARTICULATE (>8 day half-life) RELEASES Sr-89:

Ci Sr-90:

Ci

  • Value reported as CONTINUOUS RELEASE MODE.

GASEOUS EFFLUENTS - VENT STACK RELEASES - CONTINUOUS MODE I. FlSSION AND ACTIVATION GAS RELEASES Xe-133:

Ci 1.02ti+00 8.04E-01

<LLD

<LLD Xe-133m:

Ci

<LLD

<LLD 3.81 E-03

<LLD Xe-131m:

Ci

<LLD

<LLD 1.16E-01

<LLD Kr-85m:

Cl

<LLD

<LLD

<LLD 6.25E-02 Xe-135:

Ci

<LLD

<LLD

<LLD 5.00E-03 Xe-138:

Ci

<LLD

<LLD

<LLD 9.50E-02 (9916SS/XLS/051397)

Report Page12_of 31

p 4ppr;ved 5/13/97 FACSIMILE BRP 6100-6T1 Revision 4 BYRON NUCLEAR POWER STATION UNIT 2 DOCKET NUMBER STN-50-455 RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY,1998 THROUGH DECEMBER,1998 GASEOUS EFFLUENTS - VENT STACK RFI FASES - CONTINUOUS MODE (CONT.)

l UNITS l 1st Quarter l 2nd Quarter l 3rd Quarter l 4th Quarter l J. LODINE RELEASES l-131:

Ci

<LLD 4.23E-06

<LLD

<LLD l-133:

Ci

<LLD

<LLD

<LLD

<LLD l-135:

Ci

<LLD

<LLD

<LLD

<LLD l-132:

Ci

<LLD

<LLD

<LLD

<LLD K. PARTICULATE (>8 day half-life) RELEASES Sr-89:

Ci

<LLD

<LLD

<LLD

<LLD Sr-90:

Ci

<LLD

<LLD

<LLD

<LLD Br-82:

Ci 1.75E-05

<LLD

<LLD

<LLD Ba-141:

Ci 2.79E-03

<LLD

<LLD

<LLD Co-58:

Ci

<LLD 1.09E-06

<LLD

<LLD Cr-51:

Ci

<LLD 6.39E-06

<LLD

<LLD Co-60:

Ci

<LLD

<LLD

<LLD 1.30E-06 LIQUID EFFLUENTS - SUMMATION OF ALL RELEASES L. FISSION AND ACTIVATION PRODUCT RELEASES

1. Total Activity Released:

Ci 8.80E-02 1.20E-01 3.54E-02 7.26E-02

2. Average Concentration uCi/mi 3.79E-08 4.54 E-08 1.30E-08 2.52E-08 Released For Quarter:
3. % of 10CFR50 Limits
a. Quarterly Whole Body l

l 0.03 l

0.09 l

0.03 l

0.04 l

(1.5 mrem):

b. Quarterly Any Organ l

l 0.05 l

0.04 l

0.01 l

0.05 l

(5.0 mrem):

c. Annual Whole Body l

l 0.02 l

0.05 l

0.02 l

0.02 l

(3.0 mrem):

d. Annual Any Organ l

l 0.03 l

0.02 l

0.01 l

0.03 l

(10.0 mrem):

(9916SS/XLS/051397)

Report Page 13_of 31

Appr;v:d 5/13/97 FACSIMILE BRP 6100-6T1 Revision 4 BYRON NUCLEAR POWER STATION UNIT 2 DOCKET NUMBER STN-50-455 RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY,1998 THROUGH DECEMBER,1998 LlOUlD EFFLUENTS - SU^^^^ATION OF ALL RFI FASES (CONT.)

l UNITS l 1st Quarter l 2nd Quarter l 3rd Quarter l 4th Quarter l M. TRITIUM

1. Total Activity Released:

Ci 1.36E+02 7.95E+01 1.50E+02 2.85E+02

2. Average Concentration uCi/ml 5.84E-05 3.01 E-05 5.50E-05 9.89E-05_

Released For Quarter:

3. % ofITS Limit l

l 0.58 l

0.30 l

0.55 l

0.99 l

(1.00E-2 uCi/ml):

N. DISSOLVED NOBLE GASES

1. Total Activity Released:

Ci 2.97E-02 3.61 E-02 1.55E-02 1.45E-02

2. Average Concentration uCi/mi 1.28E-08 1.37E-08 5.70E-09 5.04E-09 Released For Quarter:
3. % of Tech. Reqt. Manual Limit l

l 6.39E-03 l 6.83E-03 l 2.85E-03 l 2.52E-03 l (2.00E-4 uCi/ml):

O. GROSS ALPHA

1. Total Activity Released:

Ci

<LLD

<LLD

<LLD

<LLD

2. Average Concentration uCi/ml

<LLD

<LLD

<LLD

<LLD Released For Quarter:

P. VOLUME OF WASTE l

liters l 3.42E+06 l 3.94E+06 l 1.97E+06 l 1.23E+06 l RELEASED PER UNIT:

Q. VOLUME OF DILUTION l

liters l 2.32E+09 l 2.64E+09 l 2.72E+09 l 2.89E+09]

WATER PER UNIT:

LIQUID EFFLUENTS - CONTINUOUS MODE R. LIQUID EFFLUENTS Fe-55:

Ci Sr-89:

Ci Sr-90:

Ci

  • Value reported as LlOUID EFFLUENTS - BATCH MODE

- (9916SS/XLS/051397)

Report Page14_of 31

Approved 5/13/97 FACSIMILE BRP 6100-6T1 Revision 4 BYRON NUCLEAR POWER STATION UNIT 2 DOCKET NUMBER STN-50-455 RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY,1998 THROUGH DECEMBER,1998 LIQUID EFFLUENTS - BATCH MODE I

UNITS l 1st Quarter l 2nd Quarter l 3rd Quarter l 4th Quarter l S. LIQUID EFFLUENTS Fe-55:

Ci 6.42E-03 6.67E-03 1.28E-03 6.80E-03 Sr-89:

Ci

<LLD

<LLD

<LLD

<LLD j

Sr-90:

Ci

<LLD

<LLD

<LLD

<LLD H-3:

Ci 1.36E+02 7.95E+01 1.50E+02 2.85E+02 Ar-41:

Ci 3.53E-04 5.68E-04

<LLD 6.53E-05 Cr-51:

Ci 8.97E-04 5.42E-03

<LLD 5.31E-04 Mn-54:

Ci 3.57E-04 4.18E-04 1.30E-04 1.88E-03 Fe-59:

Ci 3.07E-04 1.26E-03 1.75E-05 5.15E-05 Co-57:

Ci 3.47E-05 6.17E-05 4.44E-05 3.27E-04 Co-58:

Ci 1.34E-02 3.50E-02 1.05E-02 1.44E-02 Co-60:

Ci 1.02E-02 7.97E-03 4.23E-03 2.58E-02 Zn-65:

Ci

<LLD 5.16E-06

<LLD 4.08E-04 Kr-85:

Cl 1.98E-02 3.48E-02 1.54E-02 1.43E-02 Kr-85m:

Ci 5.89E-06

<LLD

<LLD

<LLD Kr-87:

Ci

<LLD

<LLD

<LLD

<LLD Kr-88:

Ci

<LLD

<LLD

<LLD

<LLD Sr-92:

Ci 1.28E-03 9.24E-06

<LLD 1.73E-04 Nb-95:

Ci 9.09E-04 5.23E-04 2.61 E-05 8.52E-04 Zr-95:

Ci 2.15E-05 2.19E-04

<LLD 3.46E-04 Zr-97:

Ci 9.30E-05

<LLD

<LLD 4.66E-06 Mo-99:

Ci

<LLD

<LLD

<LLD

<LLD Tc-99m:

Ci

<LLD

<LLD

<LLD

<LLD Tc-104:

Ci

<LLD

<LLD

<LLD

<LLD Ag-110m:

Ci 4.33E-03 1.25E-04 7.23E-06 5.63E-04 Sn-113:

Ci

<LLD 5.43E-06

<LLD 2.94E-05 Te-121m:

Ci

<LLD

<LLD

<LLD

<LLD Te-123m:

Ci 5.49E-03 1.78E-03 1.57E-04 7.44E-05 Te-125m:

Ci 3.78E-02 2.24E-02 1.46E-02 1.90E-02 Sb-122:

Ci 2.47E-06 1.49E-03

<LLD

<LLD Sb-124:

Ci 2.29E-03 7.87E-03 5.26E-04 4.02E-05 Sb-125:

Ci 3.69E-03 2.69E-02 3.83E-03 1.41 E-03 Sb-126:

Ci

<LLD 3.25E-04

<LLD 1.45E-06 (9916SS/XLS/051397)

Report Page 15 of11.

F Appr:vcd 5/13/97 FACSIMILE BRP 6100-6T1 Rsvision 4 BYRON NUCLEAR POWER STATION UNIT 2 DOCKET NUMBER STN-50-455 RADIOACTIVE E.~ FLUENT RELEASE REPORT JANUARY,1998 THROUGH DECEMBER,1998 LIQUID EFFLUENTS - BATCH MODE (CONT.)

l UNITS l 1st Quarter l 2nd Quarter l 3rd Quarter l 4th Quarter l S. LIQUID EFFLUENTS (CONT.)

1-131:

Ci

<LLD 1.34E-05

<LLD 8.12E-07 l-132:

Ci

<LLD

<LLD

<LLD

<LLD l-133:

Ci 2.05E-06

<LLD

<LLD

<LLD l-135:

Ci

<LLD

<LLD

<LLD

<LLD Xe-131m:

Ci

<LLD

<LLD

<LLD

<LLD Xe-133:

Ci 8.31E-03 7.61E-04 9.58E-05 1.79E-04 Xe-133m:

Ci 1.34E-04

<LLD

<LLD

<LLD Xe-135:

Ci 1.05E-03 2.31 E-06

<LLD

<LLD Xe-135m:

Ci

<LLD

<LLD

<LLD

<LLD Xe-138:

Ci

<LLD

<LLD

<LLD

<LLD Cs-134:

Ci 1.47E-04 1.15E-03 1.64E-04

<LLD Cs-137:

Ci 2.26E-04 2.09E-04 2.12E-05

<LLD Ba-140:

Ci

<LLD

<LLD

<LLD

<LLD La-140:

Ci

<LLD

<LLD

<LLD

<LLD Ce-141:

Ci

<LLD

<LLD

<LLD

<LLD Ce-144:

Ci

<LLD

<LLD

<LLD

<LLD Y-92; Ci 6.83E-05

<LLD

<LLD

<LLD I

Na-24:

Ci 3.16E-06 3.50E-05

<LLD

<LLD Br-82:

Ci

<LLD 1.70E-06

<LLD

<LLD l

Te-132:

Ci

<LLD 1.34E-05 3.75E-06

<LLD

)

T.10CFR20 PUBLIC TEDE COMPLIANCE

1. % OF 10CFR20 TEDE LIMIT:

l l

0.00 l

0.00 l

0.00 l

0.00 l

(100 mrem /yr)

(9916SS/XLS/051397)

Report Page16_of 31

BRP 6100-671 Revision 4 BYRON NUCLEAR POWER STATION i

UNIT 1/2 DOCKET NUMBER STN-50-454/455 RADIOACTIVE EFFLUENT RELEASE REPORT January.1998 THROUGH December.1996 SOLID RADIOACTIVE WASTE FOR BURIAL ist Quarter.1993 DISPOSITION OF MATERIAL VOLUME CURIES *

(DESCRIP7 ION, CLASS, TYPE, AND MODE OF DESTINATION PER PER DATE SOLIDIFYING AGENT)

TRANSPORT SHIPMENT SHIPMENT Dewatered Bead Rosin, Low Specific Activity, il21#90 Exclusive Use Barnwell, SC 4.84 2.10E+00 nos,7, UN 2912, Class A, HIC, None Dry Actwe Weste. Low Specife Actwny, nos, 1/22/98 7, UN 2912, Class A, Strong-Tight Container, Exclusive Use Oak Ridge, TN 72.55 3.28E 01 None Dry Actwo Weste, Low Specife Actway, nos, 2/3/98 7, UN 2912, Claes A, Strong-Tight Container, Exclusive Use Oak RHige, TN 72.55 3.23E-01 None Dewetered Bood Rosin, Low Specific ActMty.

2/19/98 Exclusive Use Barnwell, SC 5.83 3 41E+01 nos,7, UN 2912, Class B, HIC, None Dry Actwe Weste, Low Specife Activey, non, 2/19/98 7, UN 2912, Class A, Strong-Tight Container, Exclusive Use Memphis, TN 72.55 1.32E-01 None Dry Actwe Weste, Low Specife Actwny, nos, 2/20/98 7 UN 2912, Class A, Strong-Tight Container, Exclusive Use Memphis, TN 72.55 6.71E-02 None Dry Actwe Weste, Low Specife Actwity, nos, 2/23/98 7, UN 2912, Class A, Strong-Tight Container, Exclusive Use Memphis, TN 36.28 3 95E-03 None Dry Actwe Weste, Low Specife Activity, nos, 2/24/98 7 UN 2912, Class A, Strong-Tight Container, Exclusive Use Oak Ridge, TN 36.28 4.49E-03 None Dry Actwo Weste, and Dowatered Bead Resen, 3/tv98 Low Specife Activity, nos,7, UN 2912, Class Exclusive Use Oak Ridge.TN 72.55 1.45E+00 A, Strong-Tight Container, None 445.98 3.85E+01 QUARTERLY TOTALS NUMBER OF SHIPMENTS: Continued CUBIC M CURIES

  • CALCULATED USING MEASURED RATIOS I

i i

Report Page JZ of 31 (9916SS/XLS!O51397) i

e BRP 6100-6T1 Revision 4 BYRON NUCLEAR POWER STATION UNIT 1/2 DOCKET NUMBER STN-50454/455 RADIOACTIVE EFFLUENT RELEASE REPORT

&nuarv.1998 THROUGH December.1998 SOLID RADIOACTIVE WASTE FOR BURIAL 1st Quarter.1998 DISPOSITION OF MATERIAL VOLUME CURIES" (DESCRIPTION, CLASS, TYPE, AND MODE OF DESTINATION PER PER DATE SOLIDIFYING AGENT)

TRANSPORT SHIPMENT SHIPMENT Oil, Low Specific Activity, nos,7, UN 2912' y3 g Exclusive Use Oak Ridge, TN 36.28 1.11 E-04 Class A, Strong-Tight Container 36.28 1.11 E-04 QUARTERLY TOTALS - NUMBER OF SHIPMENTS;1Q CUBIC M CURIES j

  • CALCULATED USING MEASURED RATIOS l

Report Page ja of 31 (9916SS/XLS1051397)

e BRP 6100-6T1 Revision 4 Januarv.1998 THROUGH December.1998 SOLID RADIOACTIVE WASTE FOR BURIAL 2nd Quarter.1998 DISPOSITION OF MATERIAL VOLUME CURIES *

(DESCRIPTION, CLASS, TYPE, AND MODE OF DESTINATION PER PER DATE SOLIDIFYING AGENT)

TRANSPORT SHIPMENT SHIPMENT Dry Active Weste, Low Specife Activity, noe, 4/14/98 7, UN 2912, Class A, Strong-Tight Container, Exclusive Use Memphis, TN 72.55 6.89E 02 None Oil, Low Specife Activity, nos,7, UN 2912 Exclusive Use Oak Ridge, TN 36.28 7.99E45 Class A, Strong-Tight Container Dry Active Waste, Low Specife Activity, nos, i

5/12/98 7, UN 2912, Class A, Strong-Tight Container, Exclusive Use Oak Ridge, TN 6.15 5.72E+00 None Dewatered Bead Resin, Low Specific Activity, 914/98 Exclusive Use Barnwell, SC 4.84 1.43E+01 nos,7, UN 2912 Class A, HIC, None Dewatered Bead Resin, Low Specific Activity

  • 5/29 2 Exclusive Use Barnwell, SC 4.84 3.37E+01 nos,7, UN 2912, Class B, HIC, None Dry Active Waste, Low Specife Activity, nos, 6/11/98 7, UN 2912, Class A, Strong-Tight Container, Exclusive Use Oak Ridge, TN 72.55 2.07E 01 None Dewatered Bead Resin, low Specific Activey, Sal Lake CW, 6/26/98 Exclusive Use 23.51 3.46E-02 nos, 7, UN 2912, Class A. HlC, None UT I

220.72 5.40E+01 1

QUARTERLY TOTALS. NUMBER OF SHIPMENTS:]

CUBIC M CURIES

  • CALCULATED USING MEASURED RATIOS Report Page j9 of 3.1 (9916SS/XLS/051397)
y..

r BRP 6100-6T1 Revision 4 Jarluarv.1998 THROUGH December.1998 SOLID RADIOACTIVE WASTE FOR BURIAL 3rd Quarter.1998 DISPOSITION OF MATERIAL VOLUME CURIES

  • j (DESCRIPTION, CLASS, TYPE, AND MODE OF DESTINATION PER PER j

DATE SOLIDIFYING AGENT)

TRANSPORT SHIPMENT SHIPMENT 1

Dewatered Bead Rosin, Low Specific Activity'

"" L'

la s Sr g ta r l

Dry Actrve Weste, Low Specife Activity, nos, j

8/21/98 7, UN 2912, Class A, Strong-tight Container.

Exclusive Use Oak Ridge, TN 72.55 3.45E-05 None Dewatered Bead Rosin, Low Specific Activity' 9/11/98 Exclusive Use Barnwell, SC 4.84 4 28E+00 nos, 7, UN 2912, Class A, HIC, None Dry Active Weste, Low Specife Activity, nos, 9/15/98 7, UN 2912, Class A, Strong-tight Container, Exclusive Use Memphis, TN 38.28 1.78E-02 None E

la a, Str g Tigh Conta r 1

209.74 4.32E+00 QUARTERLY TOTALS - NUMBER OF SHIPMENTS:3 CUBIC M CURIES

  • CALCULATED USING MEASURED RATIOS l

Report Page 2Q of 31 (9918SS/XLS/051397)

r- -

n BRP 6100-6T1 Revision 4 January.1998 THROUGH December.1998 SOLID RADIOACTIVE WASTE FOR BURIAL 4th Quarter.1998 DISPOSITION OF MATERIAL VOLUME CURIES *

(DESCRIPTION, CLASS, TYPE, AND MODE OF DESTINATION PER PER DATE SOLIDIFYING AGENT)

TRANSPORT SHIPMENT SHIPMENT Dry Active Waste, Low Specife Actmty, nos, 10/15/98 7, UN 2912, Class A, Strong-tight Container, Exclusive Use Oak Ridge, TN 36.28 9 40E-05 None Dry Actwe Waste, Low Specife Actmty, nos, 10/20/98 7, UN 2912, Class A, Strong-tsht Container, Exclusive Use Oak Ridge, TN 36.28 9.29E-05 None Dry Actwe Waste, Low Specife Actmty, nos, 10/22/98 7, UN 2912, Class A, Strong-tight Container, Exclusive Use Oak Ridge, TN 36.28 9.38E-05 None Dry Actwe Waste, Low Specife Actmty, nos, 10/29/98 7, UN 2912, Class A, Strong-tight Container, Exclusive Use Oak Ridge, TN 36.28 8.97E-05 None Dry Actwe Waste, Low Specife Actmty, nos, 10/30/98 7, UN 2912, Class A, Strong-tight Container, Exclusive Use Oak Ridge, TN 72.55 1.02E-01 None Dry Actwe Waste, Low Specife Actmty, nos, 11/3/98 7, UN 2912, Class A, Strong-tight Container, Exclusive Use Oak Ridge, TN 36.28 8 68E-05 None Dry Actwo Waste, Low Specific Actmty, nos, 11/5/98 7, UN 2912, Class A, Strong-tight Container, Exclusive Use Oak Ridge, TN 36.28 8.55E-05 None Dry Actwe Waste, Low Specife Actmty, nos, 11/10/98 7, UN 2912, Class A, Strong-tight Container, Exclusive Use Oak Ridge, TN 36.28 912E-05 None Dewatered Filters, Low Specific Actmty, nos, 3 gjg Exclusive Use Barnwell, SC 5.83 9 89E+00 7, UN 2912, Class B, HIC, None+ B281 332.34 9 99E+00 QUARTERLY TOTALS - NUMBER OF SHIPMENTS: Continued CUBIC M CURIES

  • CALCULATED USING MEASURED RATIOS Report Page 21 of _Q1

. (9916SS/XLS/051397)

BRP 6100-671 Revision 4 Jerugy.1998 THROUGH December.1998 SOLID RADIOACTIVE WASTE FOR BURIAL 4TH Quarter.1998 DISPOSITION OF MATERIAL VOLUME CURIES" (DESCRINION, CLASS, TYPE, AND MODE OF DESTINATION PER PER DATE SOLIDIFYING AGENT)

TRANSPORT SHIPMENT SHIPMENT Dry Active Weste, Low Specife Activity, nos, 11/17/98 7, UN 2912, Class A, Strong-tight Container, Exclusive Use Oak Ridge, TN 38.28 1.07E-04 None g3 g Dewetered Bead Resin, Low Specific Activity' Sam a e Ch' Exclusive Use 14.51 9 47E-02 nos,7, UN 2912, Class A, HIC, None UT Dewatered Filters, Low Specifc Activity, nos, 12/14/98 7, UN 2912, Class C, HIC, None Exclusive Use Barnwell, SC 3.8 4.00E+01 Dry Active Waste and Dewatered Bead Rosin, 12/22/98 Low Specife Activity, nos,7. UN 2912, Class Exclusive Use Richland, Wa 48.44 1.51E41 A, Strong-Tight Container, None 101.03 4.02E-01 QUARTERLY TOTALS - NUMBER OF SHIPMENTS:13 CUBIC M CURIES

  • CALCULATED USING MEASURED RATIOS Report Page 22 of 31 (9916SS/XLS/051397)

I

i ADDENDUM A.

Changes to Radioactive Waste Process Control Program for 1998 were administrative.

Procedures were updated by removing references to the Radioactive Waste System known as stock. The system was not used at Byron Station. Operationally, the Process Control Program remains unchanged.

B.

Error Analysis The following is an estimate of the errors associated with effluent monitoring and analysis. The estimate is calculated using the square root of the sum of the squares methodology.

1. Gaseous Effluents Sampling error = 1 to 3.5%

Calibration error = 10%

Counting Statistics error = 5%

Vent Stack Flowrates error = 1.5%

Total error = 11 - 12%

2.

Liquid Effluents Sampling error = 1%

Calibration error = 10%

Sample volume error = 1%

Discharged volume error = 2%

Total error = 10%

3.

Waste Resin Sampling error = 5%

Counting Statistics error = 7%

Weight error = 1%

Volume error = 5%

Total error = 10%

(p:\\99byltrs\\990040 doc)

Report Page 23 of 31 e

4.

DAW Counting Statistics error = 7%

Calibration error = 10%

Weight error = 2%

Total error = 12%

C.

Meteorological and environmental impact information is reported in the Station Annual Radiological Environmental Operating Report as required by Technical Specifications 5.6.2.

D.

No limits were exceeded in liquid hold up tanks as stated in Technical Specifications 5.5.12 or in waste gas decay tanks as stated in Technical Specifications 5.5.12.

E.

There were no irradiated fuel shipments during this period.

F.

There were no elevated releases. All releases are considered vent or ground level releases.

G.

During the second quarter of 1998, surveillance OBRSR 11.k.3-1 was not completed.

Per the technical requirement manual, the building's interior sump is to be monitored for liquid quarterly. The surveillance was performed during the first quarter of 1998. It was j

not performed again until the third quarter. During the third quarter performance, the surveillance met all acceptance criteria.

H.

The site specific portion of the Offsite Dose Calculation Manual (ODCM) was revised in November of 1998. These changes were primarily administrative in nature and were performed in order to dual reference applicable sections in the Technical Requirements I

Manual and Technical Specifications which were renumbered as part of Amendment 106, to Byron Station's Technical Specifications. Additionally, the description of the Component Cooling Water monitor was moved from the Airbome Process Radiation Monitor section of the ODCM (Section 10.1) and placed in the Liquid Process Radiation Monitor section (Section 10.2), in order to retain consistency. Dairy BY-27 was removed from the REMP sampling program and Figure 11-4, due to the dairy closing down and no samples being obtained from the dairy. No replacement dairy has yet been identified, however vegetation samples are being acquired to meet ingestion pathway 4

monitoring requirements. A copy of the latest revision of the ODCM was submitted to the NRC under a separate cover by Com Ed's Generation Support Radiation Protection Department.

( p t \\ 99bylt rs \\ 99004 2.coc ) -

Report Page 24 of 31

1 1.

Attach:d cra ths Offsits Dosa CLiculations for January through December of 1998.

J.

The following data is the estimated composition of Byron's solid waste.

1.

Dry Active Waste (DAW)

2. Radwaste Resin H-3 0.05 H-3 7.98 Be-7 1.78 C-14 0.07 C-14 0.16 Mn-54 1.02 Cr-51 1.90 Fe-55 11.12 Mn-54 1.83 Co-57 0.22 i

Fe-55 22.53 Co-58 65.54 Co-57 0.20 Fe-59 0.39 Co-58 36.63 Co-60 5.25 Fe-59 1.16 Ni-63 7.30 Co-60 11.21 Sr-90

<0.01 Ni-63 16.61 Tc-99

<0.01 Zn-65 0.39 Sb-125 0.09 l

Sr-90

<0.01 1-129

<0.01 Zr-95 1.19 Cs-134 0.18 Nb-95 0.75 Cs-137 0.62 Tc-99

<0.01 Ce-144 0.20

]

Ru-103

<0.01 Pu-238

<0.01 1

Sn-113 0.43 Pu-239

<0.01 Te-123m 0.04 Pu-241

<0.01 Sb-124 1.86 Am-241

<0.01 Sb-125 2.38 Cm-242

<0.01 1-129

<0.01 Cm-244

<0.01 Cs-137 0.30 Ce-144 0.42 Hf-181 0.01 Pu-238

<0.01 Pu-239

<0.01 Pu-241

<0.01 Am-241

<0.01 Cm-242

<0.01 Cm-244

<0.01

( p t \\ 9 9bylt r s \\ 9 9004 2. doc )

Report Page 25 of 31

1 J. (Continued) 3.

Primary Resin 4.

Mechanical Filters l

H-3 4.72 l

H-3 26.51 C-14 0.10

[

C-14 0.24 Mn-54 1.26 Mn-54 0.25 Fe-55 14.70 Fe-55 31.84

)

Co-57 0.25 Co-57 0.02 Co-58 59.77 Co-58 0.38 Co-60 6.95 Co-60 15.69 Ni-63 9.65 Ni-63 23.41 Zn-65 0.13 Sr-90

<0.01 i

Sr-90 0.01 Zr-95 0.11 Nb-95 0.04 Nb-95 0.19 Tc-99

<0.01 Tc-99

<0.01 Sb-124 0.32 Sn-113 0.01 Sb-125 0.57 Sb-125 0.39 l-129

<0.01 1-129

<0.01 Cs-134 0.33 Cs-137 0.74 Cs-137 1.02 Ce-144 0.21 Ce-144 0.21 Pu-238

<0.01 Pu-238

<0.01 Pu-239

<0.01 j

Pu-239

<0.01 Am-241

<0.01 Am<241

<0.01 Pu-241 0.01 Pu-241

<0.01 Cm-242

<0.01 Cm-242

<0.01 Cm-244

<0.01 Cm-244

<0.01 K.

No process radiation monitors were out of service longer than allowed by the Offsite Dose Calculation Manual.

(p: \\ 99t ylt rs\\ 990042. doc )

Report Page 26 of 31

r ATTACHMENT A BYRON NUCLEAR POWER STATION UNIT 1/2 DOCKET NUMBER STN-50-454/455 i

RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY,1998 THROUGH DECEMBER,1998 LLD VALUES FOR GASEOUS RELEASES Isotopes LLD(Ci/ml)

H-3 3.52E-17 Ar-41 7.71 E-13 Co-58 6.95E-19 Co-60 7.93E-19 Br-82 1.28E-18 Kr-85 2.61 E-11 Kr-85m 2.24E-13 Kr-87 1.12E-12 Kr-88 9.73E-13 Sr-89 1.52E-18 Sr-90 3.48E-19 Nb-95 4.47E-19 Sn-113 4.73E-19 Sb-125 1.38E-18 Xe-125 2.46E-13 1-131 7.08E-19 Xe-131m 1.08E-12 1-132 1.15E-18 l-133 9.73E-19 Ba-133 7.26E-19 Xe-133 6.65E-13 Xe-133m 1.66E-12 Cs-134 6.67E-19 l-135 4.05E-18 Ye-135 2.39E-13 Xe-135m 7.41 E-12 Cs-137 7.25E-19 Xe-138 1.84E-11 Ba-140 1.55E-18 La-140 3.73E-19 Ba-141 1.06E-17 (pt\\99byltrs\\990042. doc)

Report Page 27 of 31

ATTACHMENT A (ctnt.)

BYRON NUCLEAR POWER STATION UNIT 1/2 DOCKET NUMBER STN-50-454/455 RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY,1998 THROUGH DECEMBER,1998 LLD VALUES FOR LIQUID RELEASES isotopes LLD(Ci/mi)

H-3 1.67E-12 Na-24 1.72E-14 Ar-41 1.05E-13 Cr-51 2.77E-13 Mn-54 5.16E-14 Fe-55 3.24E-14 Co-57, 2.60E-14 Co-58 4.00E-14 Fe-59 9.24E-14 Co-60 4.26E-14 Zn-65 1.15E-13 Kr-85 6.24E-12 Kr-85m 3.36E-14 Sr-89 5.67E-15 Sr-90 2.31 E-15 Sr-92 2.61 E-14 Y-92 4.20E-13 Nb-95 5.34E-14 Zr-95 6.19E-14 l

Zr-97 5.61 E-14 Mo-99 1.98E-14 Tc-99m 1.98E-14 Ag-110m 4.58E-14 Sn-113 4.65E-14 Sb-122 6.36E-14 Te-123m 2.20E-14 j

Sb-124 4.10E-14 Sb-125 1.41 E-13 (p \\99byltrs\\990042. doc)

Report Page 28 of 31

ATTACHMENT A (c:nt.)

BYRON NUCLEAR POWER STATION UNIT 1/2 DOCKET NUMBER STN-50-454/455 RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY,1998 THROUGH DECEMBER,1998 LLD VALUES FOR LIQUID RELEASES isotopes LLD(Ci/ml)

Te-125m 6.86E-12 Sb-126 3.50E-14 l-131 3.72E-14 Te-132 2.52E-14 l-133 4.33E-14 Xe-133 5.49E-14 Xe-133m 2.27E-13 Cs-134 4.61 E-14 Xe-135 2.66E-14 Xe-135m 1.52E-12 Cs-137 5.48E-14 Ba-140 1.31E-13 La-140 1.95E-14 Ce-141 3.85E-14 (p:\\99byltrs\\990042. doc)

Report Page 29 of 31

r----------

ATTACHMENTB BYRON NUCLEAR POWER STATION UNIT 1, (DOCKET NUMBER STN 50-454)

RADIOACTIVE EFFLUENT RELEASE REPORT STEAM GENERATOR REPLACEMENT PROJECT RELATED GROUND LEVEL RELEASES During the Steam Generator Replacement Project (SGRP) several new effluent pathways were created to support the removal and installation of Steam Generators (S/Gs) in Unit-1 Containment. Approximately 12 uCi of particulate activity was calculated to have been released via SGRP related ground level effluent pathways during 1998, using conservative assumptions. No radioiodines were identified at any effluent sampling point during the course of the project.

GROUND LEVEL UNITS 1ST QUARTER RELEASES JANUARY-MARCH 1998 Co-58:

Ci 4.69E-6 Co-60:

Ci 6.83E-6 Nb-95:

Ci 7.31 E-8 Sn-113:

Ci 4.49E-8 Sb-125:

Ci 5.57E-8 Ba-133:

Ci 3.95E-8 Cs-134:

Ci 2.48E-8 Cs-137:

Ci 5.16E-7 Total Particulate:

Ci 1.23E-5 These data were used to calculate 10CFR50 maximum doses to organs from Steam Generator Replacement Project Effluents (Particulate and tritium effluents only contribute to Organ doses using 10CFR50 methodology). The following table lists the organ dose (in mrem) to the maximally exposed infant, child, teenager, and adult member of the public:

MAXIMALLY EXPOSED

% OF 10CFR50 1ST

% OF 10CFR50 MEMBER LIMITS QUARTER LIMITS OF THE PUBLIC (7.5 mrem)

(mrem)

(7.5 mrem)

Infant 0.00 8.50E-5 0.00 Child 0.00 8.75E-5 0.00 Teenager 0.00 8.92E-5 0.00 Adult 0.00 8.64 E-5 0.00 Maximum 0.00 8.92E-5 0.00

.(ps\\99byltrs\\990042.doci Report Page 30 of 31

r_

ATTACHMENT C BYRON NUCLEAR POWER STATION UNIT 2, (DOCKET NUMBER STN-50-455)

RADIOACTIVE EFFLUENT RELEASE REPORT Unit 2 Refueling Outage Number 7 Ground Level Releases During B2R07, several miscellaneous effluent release paths were created to support the maintenance and refuel of the unit. Approximately 82 nanocuries of particulate activity was calculated to have been released via a ground level pathway using conservative assumptions.

GROUND LEVEL UNITS 2ND QUARTER RELEASES APRIL - JUNE 1998 Co-58 Ci 8.15E-8 Total Particulate Ci 8.15E-8 i

This data was used to calculate 10CFR50 maximum dose to the organs.

The following table lists the organ dose, in mrem, to the maximally exposed infant, child, teenager, and adult member of the public.

MAXIMALLY EXPOSED 2ND QUARTER

% OF 10CFR50 MEMBER LIMITS OF THE PUBLIC (7.5 mrem)

Infant 2.22E-8 0.00 Child 2.58E-8 0.00 Teenager 2.83E-8 0.00 Adult 2.39E-8 0.00 Maximum 2.83E-8 0.00 i

(Final)

{pt\\99byltts\\990042. doc)

Report Paae 31 of 31

4 8

BYRON STATION UNIT ONE ACTUAL 1998 MAXIMUM DOSES RESULTING FROM AIRBORNE RELEASES PERIOD OF RELEASE - 01/01/98 TO 12/31/98 CALCULATED 03/12/99 INFANT RECEPTOR 1ST 2ND 3RD 4TH TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC GAMMA AIR 4.37E-06 3.66E-06 2.24E-07 5.90E-06 1.42E-05 (mrad)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

BETA AIR 1.66E-05 1.39E-05 1.98E-06 8.21E-06 4.06E-05 (mrad)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

TOT. BODY 3.09E-06 2.59E-06 1.40E-07 4.44E-06 1.03E-05 l

(mrem)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

SKIN 8.41E-06 7.06E-06 1.03E-06 1.11E-05 2.76E-05 (mrem)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

ORGAN 9.58E-05 3.01E-05 3.01E-05 5.32E-05 1.67E-04 (mrem)

(SSE )

(NE )

(NE )

(NE )

(NE )

LUNG LUNG LIVER LIVER LIVER THYROID THYROID KIDNEY KIDNEY LUNG LUNG GI_LLI GI_LLI THIS IS A REPORT FOR THE CALENDAR YEAR 1998 COMPLIANCE STATUS - 10CFR 50 APP. I INFANT RECEPTOR


 % OF APP I.

QTRLY 1ST QTR 2ND QTR 3RD QTR 4TH QTR YRLY

% OF OBJ JAN-MAR APR-JUN JUL-SEP OCT-DEC OBJ APP. I GAMMA AIR (mrad)

-5.0 0.00 0.00 0.00 0.00 10.0 0.00 BETA AIR (mrad) 10.0 0.00 0.00 0.00 0.00 20.0 0.00 TOT. BODY (mrem) 2.5 0.00 0.00 0.00 0.00 5.0 0.00

)

SKIN (mrem) 7.5 0.00 0.00 0.00 0.00 15.0 0.00 ORGAN (mrem) 7.5 0.00 0.00 0.00 0.00 15.0 0.00 LUNG LUNG LIVER LIVER LIVER THYROID THYROID KIDNEY KIDNEY LUNG LUNG GI_LLI GI_LLI RESULTS BASED UPON:

ODCM ANNEX REVISION 1.3 MARCH 1996 ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995

BYRON STATION UNIT ONE ACTUAL 1998 MAXIMUM DOSES RESULTING FROM AIRBORNE RELEASES 1

PERIOD OF RELEASE - 01/01/98 TO 12/31/98 CALCULATED 03/12/99 CHILD RECEPTOR IST 2ND 3RD 4TH TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC GAMMA AIR 4.37E-06 3.66E-06 2.24E-07 5.90E-06 1.42E-05 (mrad)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

BETA AIR 1.66E-05 1.39E-05 1.98E-06 8.21E-06 4.06E-05 (mrad)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

TOT. BODY 3.09E-06 2.59E-06 1.40E-07 4.44E-06 1.03E-05 (mrem)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

SKIN 8.41E-06 7.06E-06 1.03E-06 1.11E-05 2.76E-05 (mrem)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

ORGAN 9.81E-05 7.58E-05 1.18E-04 6.17E-05 3.47E-04 (mrem)

(SSE )

(SSE )

(SSE )

(S

)

(SSE )

LUNG GI_LLI LIVER LIVER LUNG THYROID THYROID KIDNEY KIDNEY LUNG LUNG GI_LLI GI_LLI THIS IS A REPORT FOR THE CALENDAR YEAR 1998 COMPLIANCE STATUS - 10CFR 50 APP. I CHILD RECEPTOR


 % OF APP I.

QTRLY IST QTR 2ND QTR 3RD QTR 4TH QTR YRLY

% OF OBJ JAN-MAR APR-JUN JUL-SEP OCT-DEC OBJ APP. I GAMMA AIR (mrad) 5.0 0.00 0.00 0.00 0.00 10.0 0.00 BETA AIR (mrad) 10.0 0.00 0.00 0.00 0.00 20.0 0.00 i

TOT. BODY (mrem)

.2.5 0.00 0.00 0.00 0.00 5.0 0.00 i

SKIN (mrem) 7.5 0.00 0.00 0.00 0.00 15.0 0.00 ORGAN (mrem)

'7. 5 0.00 0.00 0.00 0.00 15.0 0.00 LUNG GI_LLI LIVER LIVER LUNG THYROID THYROID KIDNEY KIDNEY LUNG LUNG GI_LLI GI_LLI RESULTS BASED UPON:

ODCM ANNEX REVISION 1.3 MARCH 1996 ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995

c BYRON STATION UNIT ONE ACTUAL 1998 MAXIMUM DOSES RESULTING FROM AIRBORNE RELEASES PERIOD OF RELEASE - 01/01/98 TO 12/31/98 CALCULATED 03/12/99 TEENAGER RECEPTOR IST 2ND 3RD 4TH TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC GAMMA AIR 4.37E-06 3.66E-06 2.24E-07 5.90E-06 1.42E-05 (mrad)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

BETA AIR 1.66E-05 1.39E-05 1.98E-06 8.21E-06 4.06E-05 (mrad)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

TOT. BODY 3.09E-06 2.59E-06 1.40E-07 4.44E-06 1.03E-05 (mrem)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

SKIN 8.41E-06 7.06E-06 1.03E-06 1.11E-05 2.76E-05 (mrem)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

ORGAN 9.86E-05 4.99E-05 7.71E-05 4.41E-05 2.62E-04 (mrem)

(SSE )

(SE )

(SSE )

(S

)

(SSE )

LUNG GI_LLI LIVER LIVER LUNG THYROID THYROID KIDNEY KIDNEY LUNG LUNG GI_LLI GI_LLI THIS IS A REPORT FOR THE CALENDAR YEAR 1998 COMPLIANCE STATUS - 10CFR 50 APP. I TEENAGER RECEPTOR


- --- - - - - % O F A P P I. - - - - - - - - - - - -

QTRLY 1ST QTR 2ND QTR 3RD QTR 4TH QTR YRLY

% OF OBJ JAN-MAR APR-JUN JUL-SEP OCT-DEC OBJ APP. I GAMMA AIR (mrad) 5.0 0.00 0.00 0.00 0.00 10.0 0.00 BETA AIR (mrad) 10.0 0.00 0.00 0.00 0.00 20.0 0.00 TOT. BODY (mrem) 2.5 0.00 0.00 0.00 0.00 5.0 0.00 SKIN (mrem) 7.5 0.00 0.00 0.00 0.00 15.0 0.00 ORGAN (mrem) 7.5 0.00 0.00 0.00 0.00 15.0 0.00 LUNG GI_LLI LIVER LIVER LUNG THYROID THYROID KIDNEY KIDNEY LUNG LUNG GI_LLI GI_LLI RESULTS BASED UPON:

ODCM ANNEX REVISION 1.3 MARCH 1996 ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995

o BYRON STATION UNIT ONE ACTUAL 1998 MAXIMUM DOSES RESULTING FROM AIRBORNE RELEASES PERIOD OF RELEASE - 01/01/98 TO 12/31/98 CALCULATED 03/12/99 ADULT RECEPTOR IST 2ND 3RD 4TH TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL GAMMA AIR 43 6

6-6 2 24E 07 90 06 1.42E-05 (mrad)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

BETA AIR 1.66E-05 1.39E-05 1.98E-06 8.21E-06 4.06E-05 (mrad)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

TOT. BODY 3.09E-06 2.59E-06 1.40E-07 4.44E-06 1.03E-05 (mrem)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

SKIN 8.41E-06 7.06E-06 1.03E-06 1.11E-05 2.76E-05 (mrem)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

ORGAN 9.58E-05 4.85E-05 6.86E-05 5.24E-05 2.43E-04 (mrem)

.(SSE )

(S

)

(SE )

(S

)

(S

)

LUNG GI_LLI LIVER LIVER GI_LLI THYROID THYROID KIDNEY KIDNEY LUNG LUNG GI_LLI GI_LLI THIS IS A REPORT FOR THE CALENDAR YEAR 1998 COMPLIANCE STATUS - 10CFR 50 APP. I ADULT RECEPTOR


 % OF APP I.

QTRLY IST QTR 2ND QTR 3RD QTR 4TH QTR YRLY

% OF OBJ.

JAN-MAR APR-JUN JUL-SEP OCT-DEC OBJ APP. I GAMMA AIR (mrad) 5.0 0.00 0.00 0.00 0.00 10.0 0.00 BETA AIR (mrad) 10.0 0.00 0 00 0.00 0.00 20.0 0.00 TOT. BODY (mrem) 2.5 0.00 0.00 0.00 0.00 5.0 0.00 SKIN (mrem) 7.5 0.00 0.00 0.00 0.00 15.0 0.00 ORGAN (mrem) 7.5 0.00 0.00 0.00 0.00 15.0 0.00 LUNG GI LLI LIVER LIVER GI LLI

~

THYROID THYROID

~

I KIDNEY KIDNEY LUNG LUNG GI_LLI GI_LLI RESULTS BASED UPON:

ODCM ANNEX REVISION 1.3 MARCH 1996 ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995

v..

o BYRON STATION UNIT ONE ACTUAL 1998 MAXIMUM DOSES (mrem) RESULTING FROM AQUATIC EFFLUENTS PERIOD OF RELEASE - 01/01/98 TO 12/31/98 CALCULATED 03/12/99 INFANT RECEPTOR IST 2ND 3RD 4TH DOSE TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC TOTAL 2.36E-04 1.41E-04 2.59E-04 4.96E-04 1.13E-03 BODY INTERNAL 2.39E-04 1.45E-04 2.60E-04 4.97E-04 1.14E-03 ORGAN GI_LLI LIVER GI_LLI GI_LLI GI_LLI THIS IS A REPORT FOR THE CALENDAR YEAR 1998 COMPLIANCE STATUS - 10 CFR 50 APP. I

- -- - - - - -- -- - % OF A F P I. - -- - -- - - - - - -

QTRLY IST QTR 2ND QTR 3RD QTR 4TH QTR YRLY

% OF OBJ JAN-MAR APR-JUN JUL-SEP OCT-DEC OBJ APP. I TOTAL BODY (mrem) 1.5 0.02 0.01 0.02 0.03 3.0 0.04 CRIT. ORGAN (mrem) 5.0 0.00 0.00 0.01 0.01 10.0 0.01

~

GI_LLI LIVER GI_LLI GI_LLI GI_LLI RESULTS BASED UPON:

ODCM ANNEX REVISION 1.3 MARCH 1996 ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995

u BYRON STATION UNIT ONE 1998 ANNUAL REPORT 1

PROJECTED DOSE AT NEAREST COMMUNITY WATER SYSTEM

  • PERIOD OF RELEASE - 01/01/98 TO 12/31/98 CALCULATED 03/12/99 INFANT RECEPTOR IST 2ND 3RD 4TH DOSE TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR AP3-JUN JUL-SEP OCT-DEC TOTAL 2.36E-04 1.41E-04 2.59E-04 4.96E-04 1.13E-03 BODY INTERNAL 2.39E-04 1.45E-04 2.60E-04 4.97E-04 1.14E-03 ORGAN GI_LLI LIVER GI_LLI GI_LLI GI_LLI THIS IS A REPORT FOR THE CALENDAR YEAR 1998 COMPLIANCE STATUS - 40 CFR 141 TYPE ANNUAL LIMIT

% OF LIMIT TOTAL 4.0 mrem 0.028 BODY INTERNAL 4.0 mrem 0.028 ORGAN GI LLI 4

THIS CALCULATION OF DOSE IS BASED ON TECHNIQUES DESCRIBED IN THE COMMONWEALTH EDISON OFFSITE DOSE CALCULATION MANUAL. THESE TECHNIQUES DIFFER FROM THOSE DESCRIBED IN 40 CFR 141.

RESULTS BASED UPON:

ODCM ANNEX REVISION 1.3 MARCH 1996 j

ODCM SOFTWARE VERSION 1.1 January 1995 i

ODCM DATABASE VERSION 1.1 January 1995 i

l 1

l

i BYRON STATION UNIT ONE ACTUAL 1998 MAXIMUM DOSES (mrem) RESULTING FROM AQUATIC EFFLUENTS PERIOD OF RELEASE - 01/01/98 TO 12/31/98 CALCULATED 03/12/99 CHILD RECEPTOR IST 2ND 3RD 4TH DOSE TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC TOTAL 3.66E-04 4.57E-04 3.47E-04 6.32E-04 1.80E-03 BODY INTERNAL 9.50E-04 1.46E-03 4.89E-04 1.15E-03 3.24E-03 ORGAN GI_LLI LIVER LIVER GI_LLI LIVER THIS IS A REPORT FOR THE CALENDAR YEAR 1998 COMPLIANCE STATUS - 10 CFR 50 APP.' I


 % OF APP I.

QTRLY 1ST QTR 2ND QTR 3RD OTR 4TH QTR YRLY

% OF OBJ JAN-MAR APR-JUN JUL-SEP OCT-DEC OBJ APP. I TOTAL BODY (mrem) 1.5 0.02 0.03 0.02 0.04 3.0 0.06 CRIT. ORGAN (mrem) 5.0 0.02 0.03 0.01 0.02 10.0 0.03 GI_LLI LIVER LIVER GI_LLI LIVER RESULTS BASED UPON:

ODCM ANNEX REVISION 1.3 MARCH 1996 ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995 f

1 l

l l

m.

7.

t BYRON STATION UNIT ONE 1998 ANNUAL REPORT PROJECTED DOSE AT NEAREST COMMUNITY WATER SYSTEM

  • PERIOD'OF RELEASE - 01/01/98 TO 12/31/98 CALCULATED 03/12/99 CHILD RECEPTOR 2

IST 2ND 3RD 4TH DOSE TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC TOTAL 2.38E-04 1.42E-04 2.60E-04 4.98E-04 1.14E-03 BODY I

INTERNAL 2.44E-04 1.46E-04 2.62E-04 5.04E-04 1.16E-03 ORGAN GI_LLI GI_LLI GI_LLI GI_LLI GI_LLI THIS IS A REPORT FOR THE CALENDAR YEAR 1998 i

COMPLIANCE STATUS - 40 CFR 141 j

TYPE ANNUAL LIMIT

% OF LIMIT TOTAL 4.0 mrem 0.028 BODY INTERNAL 4.0 mrem 0.029 ORGAN GI_LLI THIS CALCULATION OF DOSE IS BASED ON TECHNIQUES DESCRIBED IN THE i

COMMONWEALTH EDISON OFFSITE DOSE CALCULATION MANUAL.

THESE TECHNIQUES DIFFER FROM THOSE DESCRIBED IN 40 CFR 141.

~

RESULTS BASED UPON:

ODCM ANNEX REVISION 1.3 MARCH 1996 ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995 i

I BYRON STATION UNIT ONE l

ACTUAL 1998 f

MAXIMUM DOSES (mrem) RESULTING FROM AQUATIC EFFLUENTS PERIOD OF RELEASE - 01/01/98 TO 12/31/98 CALCULATED 03/12/99 TEENAGER RECEPTOR j

IST 2ND 3RD 4TH DOSE TYPE

. QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC TOTAL 3.35E-04 7.76E-04 2.80E-04 3.98E-04 1.79E-03 BODY INTERNAL 1.95E-03 1.59E-03 4.40E-04 1.93E-03 5.67E-03 ORGAN GI_LLI LIVER GI_LLI GI_LLI GI_LLI THIS IS A REPORT FOR THE CALENDAR YEAR 1998 COMPLIANCE STATUS - 10 CFR 50 APP. I


 % OF APP I.

QTRLY IST OTR 2ND QTR 3RD QTR 4TH QTR YRLY

% OF OBJ JAN-MAR APR-JUN JUL-SEP OCT-DEC OBJ APP. I TOTAL BODY (mrem) 1.5 0.02 0.05 0.02 0.03 3.0 0.06 CRIT. ORGAN (mrem) 5.0 0.04 0.03 0.01 0.04 10.0 0.06 j

GI_LLI LIVER GI_LLI GI_LLI GI_LLI RESULTS BASED UPON:

ODCM ANNEX REVISION 1.3 MARCH 1996 ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995 I

BYRON STATION UNIT ONE 1998 ANNUAL REPORT PROJECTED DOSE AT NEAREST COMMUNITY WATER SYSTEM

  • PERIOD OF RELEASE - 01/01/98 TO 12/31/98 CALCULATED 03/12/99 TEENAGER RECEPTOR IST 2ND 3RD 4TH DOSE TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC TOTAL 1.24E-04 7.41E-05 1.36E-04 2.60E-04 5.94E-04 BODY

' INTERNAL 1.33E-04 8.18E-05 1.39E-04 2.70E-04 6.24E-04 ORGAN GI_LLI GI_LLI GI_LLI GI_LLI GI_LLI THIS IS A REPORT FOR THE CALENDAR YEAR 1998 COMPLIANCE STATUS - 40 CFR 141 TYPE ANNUAL LIMIT

% OF LIMIT TOTAL 4.0 mrem 0.015 BODY INTERNAL 4.0 mrem 0.016 ORGAN GI_LLI THIS CALCULATION OF DOSE IS BASED ON TECHNIQUES DESCRIBED IN THE COMMONWEALTH EDISON OFFSITE DOSE CALCULATION MANUAL. THESE TECHNIQUES DIFFER FROM THOSE DCSCRIBED IN 40 CFR 141.

RESULTS BASED UPON:

ODCM ANNEX REVISION 1.3 MARCH 1996 j

ODCM SOFTWARE VERSION 1.1 January 1995 1

1 ODCM DATABASE VERSION 1.1 January 1995 l

L L

a o

r BYRON STATION UNIT ONE ACTUAL 1998 l

MAXIMUM DOSES (mrem) RESULTING FROM AQUATIC EFFLUENTS PERIOD OF RELEASE - 01/01/98 TO 12/31/98 CALCULATED 03/12/99 ADULT RECEPTOR IST 2ND 3RD 4TH DOSE TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC l

TOTAL 5.08E-04 1.31E-03 4 -.17 E-0 4 5.29E-04 2.76E-03 l

BODY INTERNAL 2.71E-03 1.88E-03 5.96E-04 2.72E-03 7.91E-03 ORGAN l

GI_LLI GI_LLI GI_LLI GI_LLI GI_LLI THIS IS A REPORT FOR THE CALENDAR YEAR 1998 COMPLIANCE STATUS - 10 CFR 50 APP. I


 % OF APP I, QTRLY IST QTR 2ND QTR 3RD QTR 4TH QTR YRLY

% OF OBJ JAN-MAR APR-JUN JUL-SEP OCT-DEC OBJ APP. I TOTAL BODY (mrem) 1.5 0.03 0.09 0.03 0.04 3.0 0.09 l

CRIT. ORGAN (mrem) 5.0 0.05 0.04 0.01 0.05 10.0 0.08 l

GI_LLI GI_LLI GI_LLI GI_LLI GI_LLI RESULTS BASED UPON:

ODCM ANNEX REVISION 1.3 MARCH 1996 ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995 l

l b~

BYRON STATION UNIT ONE 1998 ANNUAL RErORT PROJECTED DOSE AT NEAREST COMMUNITY WATER SYSTEM -

PERIOD OF RELEASE - 01/01/98 TO 12/31/98 CALCULATED 03/12/99 ADULT RECEPTOR IST 2ND 3RD 4TH DOSE TYPE QUARTER QUARTER-QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC TOTAL 1.75E-04 1.05E-04 1.93E-04 3.67E-04 8.40E-04 BODY INTERNAL 1.89E-04 1.17E-04 1.98E-04 3.84E-04 8.88E-04 ORGAN GI_LLI GI_LLI GI_LLI GI_LLI GI_LLI THIS IS A REPORT FOR THE CALENDAR YEAR 1998 COMPLIANCE STATUS - 40 CFR 141 TYPE ANNUAL LIMIT

% OF LIMIT TOTAL 4.0 mrem 0.021 BODY INTERNAL 4.0 mrem 0.022 ORGAN GI_LLI THIS CALCULATION OF DOSE IS - BASED ON TECHNIQUES DESCRIBED IN THE COMMONWEALTH EDISON OFFSITE DOSE CALCULATION MANUAL. THESE TECHNIQUES DIFFER FROM THOSE DESCRIBED IN 40 CFR 141.

l

\\

RESULTS BASED UPON:

ODCM ANNEX REVISION 1.3 MARCH 1996 ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995 1

I BYRON STATION UNIT ONE 10 CFR 20 COMPLIANCE ASSESSMENT PERIOD OF ASSESSMENT 01/01/98 TO 12/31/98 CALCULATED 03/22/99 l

i 1.

10 CFR 20.1301 (a) (1) Compliance Total Effective Dose Egivalent, mrem /yr 3.41E-03 10 CFR 20.1301 (a) (1) limit mrem /yr 100.0 g

% of limit 0.00 l

Compliance Summary - 10CFR20 l

1st 2nd 3rd 4th

% of i

Otr Qtr Qtr Qtr Limit l

TEDE 9.38E-04 1.21E-03 4.18E-04 8.38E-04 0.00 l

i l

RESULTS BASED UPON: ODCM ANNEX REVISION 1.3 MARCH 1996 ODCM SOFTWARE VERSION 1.1 January 1995 l

ODCM DATABASE VERSION 1.1 January 1995 I

i BYRON STATION UNIT ONE 10 CFR 20 COMPLIANCE ASSESSMENT PERIOD OF ASSESSMENT 01/01/98 TO 12/31/98

.n CALCULATED 03/22/99 2,

10'CFR 20.1301 (d)/40 CFR 190 Compliance Dose Limit

% of (mrem)

(mrem)

Limit j

Whole Body Plume 1.03E-05 (DDE)

Skyshine

-0.00E+00 j

Ground 8.61E-05 l

l Total 9.64E-05 25.0 0.00 l

Organ Dose Thyroid 1.93E-03 75.0 0.00 l-(

l (CDE)

Gonads 2.89E-03 25.0 0.01 l

Breast 2.01E-03 25.0 0.01 Lung 1.96E-03 25.0 0.01 l

t l

Marrow 2.94E-03 25.0 0.01 l

Bone 1.03E-02 25.0 0.04 1

Remainder 4.43E-03 25.0 0.02 i

CEDE 3.31E-03 TEDE 3.41E-03 100.0 0.00

~

RESULTS BASED UPON: ODCM ANNEX REVISION 1.3 MARCH 1996 ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995

c BYRON STATION UNIT TWO ACTUAL 1998 MAXIMUM DOSES RESULTING FROM AIRBORNE RELEASES PERIOD OF RELEASE - 01/01/98 TO 12/31/98 CALCULATED 03/12/99 INFANT RECEPTOR IST 2ND 3RD 4TH TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC GAMMA AIR 5.84E-06 5.22E-06 6.99E-07 5.84E-06 1.76E-05 (mrad)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

BETA AIR 1.73E-05 1.48E-05 2.76E-06 7.97E-06 4.29E-05

~(mrad)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

TOT. BODY 4.19E-06 3.76E-06 4.90E-07 4.39E-06 1.28E-05 (mrem)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

SKIN 1.02E-05 8.86E-06 1.75E-06 1.10E-05 3.18E-05 (mrem)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

ORGAN 6.94E-05 5.79E-05 8.08E-05 1.27E-04 3.35E-04 (mrem)

(NE- )

(NE )

(NE )

(NE )

(NE )

GI_LLI THYROID LIVER LUNG THYROID THYROID KIDNEY LUNG GI_LLI THIS IS A REPORT FOR THE CALENDAR YEAR 1998 COMPLIANCE STATUS - 10CFR 50 APP. I INFANT RECEPTOR


 % OF APP I.

QTRLY 1ST OTR 2ND QTR 3RD OTR 4TH QTR YRLY

% OF OBJ JAN-MAR APR-JUN JUL-SEP OCT-DEC OBJ APP. I GAMMA AIR (mrad) 5.0 0.00 0.00 0.00 0.00 10.0 0.00 BETA AIR (mrad) 10.0 0.00 0.00 0.00 0.00 20.0 0.00 TOT. BODY (mrem) 2.5 0.00 0.00 0.00 0.00 5.0 0.00 SKIN (mrem) 7.5 0.00 0.00 0.00 0.00 15.0 0.00 ORGAN (mrem) 7.5 0.00 0.00 C.00 0.00 15.0 0.00 GI_LLI THYROID LIVER LUNG THYROID THYROID KIDNEY LUNG GI_LLI RESULTS BASED UPON:

ODCM ANNEX REVISION 1.3 MARCH 1996 ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1 1 January 1995

e-e o

BYRON STATION UNIT TWO ACTUAL 1998 MAXIMUM DOSES RESULTING FROM AIRBORNE RELEASES PERIOD OF RELEASE - 01/01/98 TO 12/31/98 CALCULATED 03/12/99 CHILD RECEPTOR IST 2ND 3RD 4TH TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC GAMMA AIR 5.84E-06 5.22E-06 6.99E-07 5.84E-06 1.76E-05 (mrad)-

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

BETA AIR 1.73E-05 1.48E-05 2.76E-06 7.97E-06 4.29E-05 (mrad)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

TOT. BODY.

4.19E-06 3.76E-06 4.90E-07 4.39E-06 1.28E-05 (mrem)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

SKIN 1.02E-05 8.86E-06 1.75E-06 1.10E-05 3.18E-05 (mrem)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

ORGAN 4.89E-05 1.05E-04 3.17E-04 1.63E-04 5.97E-04 (mrem)

(NE )

(SE

)

(SSE )

(S

)

(SE )

LUNG THYROID LIVER LUNG THYROID j

THYROID KIDNEY j

LUNG I

GI_LLI THIS IS A REPORT FOR THE CALENDAR YEAR 1998 COMPLIANCE STATUS - 10CFR 50 APP. I CHILD RECEPTOR


 % OF APP I.

QTRLY 1ST QTR 2ND QTR 3RD QTR 4TH QTR YRLY

% OF OBJ JAN-MAR APR-JUN JUL-SEP OCT-DEC OBJ APP. I GAMMA AIR (mrad) 5.0 0.00 0.00 0.00 0.00 10.0 0.00 BETA AIR (mrad) 10.0 0.00 0.00 0.00 0.00 20.0 0.00 TOT. BODY (mrem) 2.5 0.00 0.00 0.00 0.00 5.0 0.00 SKIN (mrem) 7.5 0.00 0.00 0.00 0.00 15.0 0.00

)

ORGAN (mrem) 7.5 0.00 0.00 0.00 0.00 15.0 0.00 LUNG THYROID LIVER LUNG THYROID THYROID KIDNEY LUNG GI_LLI RESULTS BASED UPON:

ODCM ANNEX REVISION 1.3 MARCH 1996 ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995

BYRON STATION UNIT TWO ACTUAL 1998 MAXIMUM DOSES RESULTING FROM AIRBORNE RELEASES j

PERIOD OF RELEASE - 01/01/98 TO 12/31/98 CALCULATED 03/12/99 TEENAGER RECEPTOR 1ST 2ND 3RD 4TH TYPE QUARTER QUARTER-QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC GAMMA AIR 5.84E-06 5.22E-06 6.99E-07 5.84E-06 1.76E-05 (mrad)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

BETA AIR 1.73E-05 1.48E-05 2.76E-06 7.97E-06 4.29E-05 (mrad)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

TOT. BODY 4.19E-06 3.76E-06 4.90E-07 4.39E-06 1.28E-05 (mrem)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

SKIN 1.02E-05 8.86E-06 1.75E-06 1.10E-05 3.18E-05 (mrem)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

ORGAN 3.19E-05 7.01E-05 2.07E-04 1.16E-04 3.98E-04 (mrem)

(NE )

(SE )

(SSE )

(S

)

(SE )

i LUNG THYROID LIVER LUNG THYROID l

THYROID KIDNEY LUNG GI_LLI THIS IS A REPORT FOR THE CALENDAR YEAR 1998 COMPLIANCE STATUS - 10CFR 50 APP. I TEENAGER RECEPTOR


 % OF APP I.

QTRLY IST QTR 2ND QTR 3RD QTR 4TH QTR YRLY

% OF OBJ JAN-MAR APR-JUN JUL-SEP OCT-DEC OBJ APP. I GAMMA AIR (mrad) 5.0 0.00 0.00 0.00 0.00 10.0 0.00 BETA AIR (mrad) 10.0 0.00 0.00 0.00 0.00 20.0 0.00 TOT. BODY (mrem) 2.5 0.00 0.00 0.00 0.00 5.0 0.00 SKIN (mrem) 7.5 0.00 0.00 0.00 0.00 15.0 0.00 ORGAN (mrem) 7.5 0.00 0.00 0.00 0.00 15.0 0.00 LUNG THYROID LIVER LUNG THYROID THYROID KIDNEY LUNG GI_LLI RESULTS BASED UPON:

ODCM ANNEX REVISION 1.3 MARCH 1996 ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995

g

?

');

l BYRON STATION UNIT TWO ACTUAL 1998 MAXIMUM DOSES RESULTING FROM AIRBORNE RELEASES PERIOD OF RELEASE - 01/01/98 TO 12/31/98 CALCULATED 03/12/99 ADULT RECEPTOR IST 2ND 3RD 4TH TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC GAMMA AIR 5.84E-06 5.22E-06 6.99E-07 5.84E-06 1.76E-05 (mrad)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

BETA AIR 1.73E-05 1.48E-05 2.76E-06 7.97E-06 4.29E-05 (mrad)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

TOT. BODY 4.19E-06 3.76E-06 4.90E-07 4.39E-06 1.28E-05 (mrem)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

SKIN 1.02E-05 8.86E-06 1.75E-06 1.10E-05 3.18E-05 (mrem)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

ORGAN 4.44E-05 7.55E-05 1.84E-04 1.35E-04 4.32E-04 (mrem)

(S

)

(S

)

(SE )

(S

)

(S

)

LUNG THYROID LIVER GI_LLI THYROID THYROID KIDNEY LUNG GI_LLI THIS IS A REPORT FOR THE CALENDAR YEAR 1998 COMPLIANCE STATUS - 10CFR 50 APP. I ADULT RECEPTOR


 % OF APP I. ------------

QTRLY IST QTR 2ND QTR 3RD QTR 4TH QTR YRLY

% OF OBJ JAN-MAR APR-JUN JUL-SEP OCT-DEC OBJ APP. I GAMMA AIR (mrad) 5.0 0.00 0.00 0.00 0,00 10.0 0.00 DETA AIR (mrad) 10.0 0.00 0.00 0.00 0.00 20.0 0.00 TOT. BODY (mrem) 2.5 0.00 0.00 0.00 0.00 5.0 0.00 SKIN (mrem) 7.5 0.00 0.00 0.00 0.00 15.0 0.00

. ORGAN (mrem) 7.5 0.00 0.00 0.00 0.00 15.0 0.00 LUNG THYROID LIVER GI_LLI THYROID THYROID KIDNEY LUNG GI_LLI RESULTS BASED UPON:

ODCM ANNEX REVISION 1.3 MARCH 1996 I

ODCM SOFTWARE VERSION 1.1 January 1995 l

ODCM DATABASE VERSION 1.1 January 1995 I

i L

4 BYRON STATION UNIT TWO ACTUAL 1998 MAXIMUM DOSES (mrem) RESULTING FROM AQUATIC EFFLUENTS PERIOD OF RELEASE - 01/01/98 TO 12/31/98 CALCULATED 03/12/99 INFANT RECEPTOR IST 2ND 3RD 4TH DOSE TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC TOTAL 2.36E-04 1.41E-04 2.59E-04 4.96E-04 1.13E-03 BODY j

INTERNAL 2.39E-04 1.45E-04 2.60E-04 4.97E-04 1.14E-03 i

ORGAN GI_LLI LIVER GI_LLI GI_LLI GI_LLI j

4 THIS IS A REPORT FOR THE CALENDAR YEAR 1998 I

COMPLIANCE STATUS - 10 CFR 50 APP. I


 % OF APP I.

QTRLY IST QTR 2ND QTR 3RD QTR 4TH QTR YRLY

% OF OBJ JAN-MAR APR-JUN JUL-SEP OCT-DEC OBJ APP. I TOTAL BODY (mrem) 1.5 0.02 0.01 0.02 0.03 3.0 0.04 CRIT. ORGAN (mrem) 5.0 0.00 0.00 0.01 0.01 10.0 0.01 4

GI_LLI LIVER GI_LLI GI_LLI GI_LLI l

RESULTS BASED UPON:

ODCM ANNEX REVISION 1.3 MARCH 1996 I

ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995 l

1

b'-

4 4

BYRON STATION UNIT TWO 1998 ANNUAL REPORT PROJECTED DOSE AT NEAREST COMMUNITY WATER SYSTEM

  • PERIOD OF RELEASE - 01/01/98 TO 12/31/98 CALCULATED 03/12/99 INFANT RECEPTOR 1ST 2ND 3RD 4TH DOSE TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC TOTAL 2.36E-04 1.41E-04 2.59E-04 4.96E-04 1.13E-03 BODY INTERNAL 2.39E-04 1.45E-04 2.60E-04 4.97E-04 1.14E-03 ORGAN GI_LLI LIVER Gl_LLI GI_LLI GI_LLI THIS IS A REPORT FOR THE CALENDAR YEAR 1998 COMPLIANCE STATUS - 40 CFR 141 TYPE ANNUAL LIMIT

% OF LIMIT TOTAL 4.0 mrem 0.028 BODY INTERNAL 4.0 mrem 0.028 ORGAN I

GI_LLI THIS CALCULATION OF DOSE IS BASLD ON TECHNIQUES DESCRIBED IN THE COMMONWEALTH EDISON OFFSITE DOSE CALCULATION MANUAL. THESE TECHNIQUES DIFFER FisOM THOSE DESCRIBED IN 40 CFR 141.

RESULTS BASED UPON:

ODCM ANNEX REVISION 1.3 MARCH 1996 ODCM SOFTWARE VERSION 1.1 January 1995 OPCM DATABASE VERSION 1.1 January 1995 I

i

r_

e

  • C BYRON STATION UNIT TWO ACTUAL 1998 MAXIMUM DOSES (mrem) RESULTING FROM AQUATIC EFFLUENTS PERIOD OF RELEASE - 01/01/98 TO 12/31/98 CALCULATED 03/12/99 CHILD RECUPTOR IST 2ND 3RD 4TH DOSE TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC TOTAL 3.66E-04 4.57E-04 3.47E-04 6.32E-04 1.80E-03 BODY INTERNAL 9.50E-04 1.46E-03 4.89E-04 1,15E-03 3.24E-03 ORGAN GI_LLI LIVER LIVER GI_LLI LIVER THIS IS A REPORT FOR THE CALENDAR YEAR 1998 COMPLIANCE STATUS - 10 CFR 50 APP. I

 % OF APP I.

QTRLY IST QTR 2ND QTR 3RD QTR 4TH QTR YRLY

% OF OBJ JAN-MAR APR-JUN JUL-SEP OCT-DEC OBJ APP. I TOTAL BODY (mrem) 1.5 0.02 0.03 0.02 0.04 3.0 0.06 CRIT. ORGAN (mrem) 5.0 0.02 0.03 0.01 0.02 10.0 0.03 GI_LLI LIVER LIVER GI_LLI LIVER RESULTS BASED UPON:

ODCM ANNEX REVISION 1.3 MARCH 1996 ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995 i

1 1

l i

1

r~

l 4

BYRON STATION. UNIT TWO 1998 ANNUAL REPORT PROJECTED DOSE AT NEAREST COMMUNITY WATER SYSTEM

  • PERIOD OF RELEASE - 01/01/98 TO 12/31/98 CALCULATED 03/12/99 CHILD RECEPTOR IST 2ND 3RD 4TH.

DOSE TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC TOTAL 2.38E-04 1.42E-04 2.60E-04 4.98E-04 1.14E-03 i

BODY J

INTERNAL 2.44E-04 1.46E-04 2.62E-04 5.04E-04 1.16E-03 ORGAN GI_LLI GI_LLI GI_LLI GI_LLI GI_LLI THIS IS A REPORT FOR THE CALENDAR YEAR 1998 1

COMPLIANCE STATUS - 40 CFR 141 TYPE ANNUAL LIMIT

% OF LIMIT TOTAL 4.0 mrem 0.028 BODY INTERNAL 4.0 mrem 0.029 ORGAN j

GI_LLI THIS CALCULATION OF DOSE IS BASED ON TECHNIQUES DESCRIBED IN THE COMMONWEALTH EDISON OFFSITE DOSE CALCULATION MANUAL.

THESE TECHNIQUES DIFFER FROM THOSE DESCRIBED IN 40 CFR 141.

RESULTS BASED UPON:

ODCM ANNEX REVISION 1.3 MARCH 1996 ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995 i

j i

I

i-t.

e 9

BYRON STATION UNIT TWO ACTUAL 1998 MAXIMUM DOSES (mrem) RESULTING FROM AQUATIC EFFLUENTS PERIOD OF RELEASE - 01/01/98 TO 12/31/98 CALCULATED 03/12/99 TEENAGER RECEPTOR IST 2ND 3RD 4TH DOSE TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC TOTAL 3.35E-04 7.76E-04 2.80E-04 3.98E-04 1.79E-03 BODY INTERNAL 1.95E-03 1.59E-03 4.40E-04 1.93E-03 5.67E-03 ORGAN GI_LLI LIVER GI_LLI GI_LLI GI_LLI THIS IS A REPORT FOR THE CALENDAR YEAR 1996 COMPLIANCE STATUS - 10 CFR 50 APP. I


 % OF APP I.

QTRLY 1ST QTR 2ND QTR 3RD QTR 4TH QTR YRLY

% OF OBJ JAN-MAR APR-JUN JUL-SEP OCT-DEC OBJ APP. I TOTAL BODY (mrem) 1.5 0.02 0.05 0.02 0.03 3.0 0.06 CRIT. ORGAN (mrem) 5.0 0.04 0.03 0.01 0.04 10.0 0.06 GI_LLI LIVER GI_LLI GI_LLI GI_LLI RESULTS BASED UPON:

ODCM ANNEX REVISION 1.3 MARCH 1996 ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995

o BYRON STATION UNIT TWO 1998 ANNUAL REPORT PROJECTED DOSE AT NEAREST COMMUNITY WATER SYSTEM

  • PERIOD OF RELEASE - 01/01/98 TO 12/31/98 CALCULATED 03/12/99 TEENAGER RECEPTOR IST 2ND 3RD 4TH DOSE TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL l

JAN-MAR APR-JUN JUL-SEP OCT-DEC TOTAL 1.24E-04 7.41E-05 1.36E-04 2.60E-04 5.94E-04 BODY INTERNAL 1.33E-04 8.18E-05 1.39E-04 2.70E-04 6.24E-04 ORGAN GI_LLI GI_LLI GI_LLI GI_LLI GI_LLI THIS IS A REPORT FOR THE CALENDAR YEAR 1998 i

COMPLIANCE STATUS - 40 CFR 141 TYPE ANNUAL LIMIT

% OF LIMIT TOTAL 4.0 mrem 0.015 BODY INTERNAL 4.0 mrem 0.016 ORGAN GI_LLI THIS CALCULATION OF DOSE IS BASED ON TECHNIQUES DESCRIBED IN THE COMMONWEALTH EDISON OFFSITE DOSE CALCULATION MANUAL. THESE TECHNIQUES DIFFER FROM THOSE DESCRIBED IN 40 CFR 141.

RESULTS BASED UPON:

ODCM ANNEX REVISION 1.3 MARCH 1996 ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995

r i.

l BYRON STATION UNIT TWO ACTUAL 1998 MAXIMUM DOSES (mrem) RESULTING FROM AQUATIC EFFLUENTS PERIOD OF RELEASE - 01/01/98 TO 12/31/98 CALCULATED 03/12/99 ADULT RECEPTOR IST 2ND 3RD 4TH DOSE TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC TOTAL 5.08E-04 1.31E-03 4.17E-04 5.29E-04 2.76E-03 BODY INTERNAL 2.71E-03 1.88E-03 5.96E-04 2.72E-03 7.91E-03 ORGAN GI_LLI GI_LLI GI_LLI GI_LLI GI_LLI THIS IS A REPORT FOR THE CALENDAR YEAR 1998 COMPLIANCE STATUS - 10 CFR 50 APP. I

- -- - - - - - - - - - % O F A P P I. -- - -- - -- - - --

QTRLY 1ST QTR 2ND QTR 3RD QTR 4TH QTR YRLY

% OF OBJ JAN-MAR APR-JUN JUL-SEP OCT-DEC OBJ APP. I TOTAL BODY (mrem) 1.5 0.03 0.09 0.03 0.04 3.0 0.09 CRIT. ORGAN (mrem) 5.0 0.05 0.04 0.01 0.05 10.0 0.08 GI_LLI GI_LLI GI_LLI GI_LLI GI_LLI RESULTS BASED UPON:

ODCM ANNEX REVISION 1.3 MARCH 1996 ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995 I

I

o ae s

BYRON STATION UNIT TWO i

1998 ANNUAL REPORT PROJECTED DOSE AT NEAREST COMMUNITY WATER SYSTEM

  • PERIOD OF RELEASE - 01/01/98 TO 12/31/98 CALCULATED 03/12/99 ADULT RECEPTOR IST 2ND 3RD 4TH I

DOSE TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC l

TOTAL 1.75E-04 1.05E-04 1.93E-04 3.67E-04 8.40E-04 BODY INTERNAL 1.89E-04 1.17E-04 1.98E-04 3.84E-04 8.88E-04 ORGAN GI_LLI GI_LLI GI_LLI GI_LLI GI_LLI THIS IS A REPORT FOR THE CALENDAR YEAR 1998 COMPLIANCE STATUS - 40 CFR 141 TYPE ANNUAL LIMIT

% OF LIMIT TOTAL 4.0 mrem 0.021 BODY INTERNAL 4.0 mrem 0.022 ORGAN

]

GI_LLI THIS CALCULATION OF DOSE IS BASED ON TECHNIQUES DESCRIBED IN THE COMMONWEALTH EDISON OFFSITE DOSE CALCULATION MANUAL.

THESE TECHNIQUES DIFFER FROM THOSE DESCRIBED IN 40 CFR 141.

RESULTS BASED UPON:

ODCM ANNEX REVISION 1.3 MARCH 1996 ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995

1 e ** 4 BYRON STATION UNIT TWO 10 CFR 20 COMPLIANCE ASSESSMENT PERIOD OF ASSESSMENT 01/01/98 TO 12/31/98 CALCULATED 03/22/99

1. 10 CFR 20.1301 (a) (1) Compliance I

Total Effective Dose Egivalent, mrem /yr 3.53E-03 10 CFR 20.1301 (a) (1) limit mrem /yr 100.0

% of limit 0.00 Compliance Summary - 10CFR20 1st 2nd 3rd 4th

% of l

Qtr Qtr Qtr Qtr Limit I

TEDE 8.74E-04 1.24E-03 5.11E-04 9.08E-04 0.00 RESULTS BASED UPON: ODCM ANNEX REVISION 1.3 MARCH 1996 ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995 i

I

F -

ye. a BYRON STATION UNIT TWO 10 CFR 20 COMPLIANCE ASSESSMENT PERIOD OF ASSESSMENT 01/01/98 TO 12/31/98 CALCULATED 03/22/99

2. 10 CFR 20.1301 (d)/40 CFR 190 Compliance Dose Limit

% of (mrem)

(mrem)

Limit Whole Body Plume 1.28E-05 (DDE)

Skyshine 0.00E+00 Ground 3.75E-06 j

Total 1.66E-05 25.0 0.00 Organ Dose Thyroid 2.14E-03 75.0 0.00 (CDE)

Gonads 3.09E-03 25.0 0.01

(

l Breast 2.21E-03 25.0 0.01 I

Lung 2.16E-03 25.0 0.01 Marrow 3.14E-03 25.0 0.01

)