Page 1 SAFETY EVALUATION CONNECTICUT YANKEC STEAM GENERATOR TUBE REPAIR I.
INTRODUCTION This safety evaluation provides an assessment of the effect of the steam generator tube repair program on the structural integrity of the reactor coolant system.
The methods of repair aro described and evaluated with respect to the plant design basis and impact on plant operating performance.
In addition, the criteria of 10 CFR 50.59 are applied to ensure that all cafety related issues are satisfactorily addressed.
Eddy current test data obtained in 1983 and 1984 has established that the steam generator U-tubes are experiencing secondary side
'lo dat.o 3 59 'g.L pitting corrosion.
Severely pitted tubes can be removed from ser-4' vice by plugging, or they may be repaired by sleeving.
03 of a total 15,176 tubes have been plugged per the criteria estab-lished in the Connecticut Yankee Safety Technical Specification.
Due to the large number of defective tubes expected during the 1946 outage, a repair contingency to install sleeves has been developed to minimize impact on plant performaaco and to extend the useful life of the steam generators.
It has thus been proposed that the
+
Safety Technical Specification be revised to allow cleeving as a repair optiong.
As a result of recent work, the plant s&fety anal-ysis is also being revised to increase the plugging limit from 40G
\\
total tubes plugged to 500 plugged tubes per steam generater ()).
Sleeving of tubes will reduce heat transfer capability and primary flow.
It has been calculated that 14 sleeves are conservatively equivalent to one plugged tube (2, 3).
Using this ratio, the fol-
, lowing equation describes the sleeve and plug combinati0ns that can be installed in each steam generator.
J S/14 + (P + p) 1 500
- where, S is the number of sleeves that can be installed, P is the number of tubes already plugged, and p is the number of tubes that are available for plugging.
P G
Page 2 SAFETY EVALUATION CONNECTICUT YANKEE STEAM GENERATOR TUBE REPAIR A further breakdown of the maximum number of sleeves that can be installed per steam generator is given in the table below:
S(p) p max., S=o S max.,p=o 1 2 8 **
- 1 1 < ((318-p) 372-p) 14 372 5,208 S
5 14 318 4,452 2
182 S 2 3
24 S
1 (476-p) 14 476 6,664 3
4 25 S4 1 (475-p) 14 475 6,650 The actual number of sleeves installed will be detailed in the turnover memo at the end of the outage.
Leakage from sleeved tubes in excess of plant Technical Specifica-tion limits has also been considered.
Under normal operating con-ditions oleeved tubes are warranted by Westinghouse to leak no more than 10 drops / min.
At this rate it is calculated that 749 sleeves /
steam generator can be installed and leak without exceeding Techni-cal Specifications.
l 0.1 gal x 3784.4 mi,x 19.8 drops x 0.1 min sleeves = 749 sleeves l
min SG gal al drop SG It is concluded that leakage due to normal operating conditions should not limit the number of sleeves installed since:
1)
Actual leak rates experienced during qualification testing are 0 to 2 drops / min.
2)
Currently, there are no known leaking tubes in the steam gen-eratorS.
u 3)
Installed sleeves by design will not degrade the pressure re-taining capabflity of the tube.
4)
Small primary to secondary leaks can be detected and actions taken prior to exceeding the Technical Specification limit.
m,,mpw o, _m.
d-(gp6 ruso i
, _m.
m s., 2 _3 S
e
Page 3 SAFETY EVALUATION CONNECTICUT YANKEE STEAM GENERATOR TUBE REPAIR For faulted conditions maximum leakage is limited to 8.1 gal / min per steam generator.
Qualification testing establishes that sleeved tubes can be expected to leak at a rate no higher than 20 drops / min.
The maximum number of sleeves that can be installed may be calcu-lated as before:
8.1 ga_1 x 3784.4 a1 x 19.8 drops x 0.05 min sleeve = 30,347 sleeves min. SG gal al drops SG It is clear that if all tubes were sleeved on both ends, a factor of safety of four is realized against excessive leakage.
Thus, sleev-ing limits baced on thermal hydraulic ef fects is the more limiting case.
II.
R_EPAIR PROCESS A,
Description of Sleeving The repair process requires that sleeves be inserted in-side defective steam generator tubes in a manner to com-pletely span the defective tube region.
Plastic expansion of the sleeve against the tube, at the top and bottom of the sleeve, providen a leak limiting joint which exhibits sufficient mecnanical strength to withstand normal operat-
- ing, test, and postulated accident loading conditions.
The expanded sleeve forms a new section of the reactor coolant pressure boundary.
The repair process involves honing of the defective steam generator tube in the region to be sleeved, installation, followed by mechanical expansion of the sloeve.
An eddy current test is then conducted to establish that the joint is properly expanded and accurately located.
This exami-nation also provides baseline data for future eddy current test examination.
1 h
6 e
4
e Page 4 SAFETY EVALUATION CONNECTICUT YANKEE STEAM GENERATOR TUBE REPAIR B.
Description of Plugging Plugging removes defective tubes from service.
Mechanical plugs will be used during the 1986 Connecticut Yankee re-fuel outage.
The plug has ribbed sides and a built-in ex-pander.
As the expander is pulled down, an internal cone forces the ribs into the wall of the defective tube.
A plug is installed in both ends of the defective tube, thereby eliminating the tube from the reactor coolant pressure boundary.
C.
Applicable Codes The repair program will be conducted in accordance with ASME Section XI, 1980 Edition through Winter 1980 Addenda, and meet the requirements of the original equipment speci-fication; Regulatory Guide 1.83 Steam Genetator Tubing Inspectability; and Regulatory Guide 1.121 - Steam Gener-ator Tube Plugging Margin.
III. DESIGN BASES A.
O_riginal Design Bases The original design bases for Connecticut Yankee steam g e ne ra tors include the ASME Boiler and Pressure Vessel
- Code,Section VIII, 1962 Edition, the Safety Technical Specification, Facility Description and Safety Analysis, Combustion Engineering, Inc. Report No. 1090:
Analytical Report for Connecticut Yankee Reactor Vessel, January 1965, Westinghouse Electric Corp. Technical Manual 1440-C78' for Model 27 Steam Generator, December 1966, Westing-house Report WNEP-8521:
Connecticut Yankee Steam Genera-tors Stress Report, 4-1-85, and ASME Code Case No. 1270N.
8.
Proposed Change for Slesving The Safety Technical Specification inust be modified to allow repair of defective steam generator tubes by sleeve insta31ation.
The design bases for this change include all of the above original design bases, ASME Section III, 1980 Edition through Winter 1980 Addenda, and Westinghouse.
Report:
WCAP 11008, Ccntiecticut Yankee Steam Generator Sleeving Report (Mechanical Sleeven), January 1986.
I
~
Page 5 SAFETY EVALUATION CONNECTICUT YANKEE STEAM GENERATOR TUBE REPAIR The tube repeir program planned for the Connecticut Yankee steam generators is essentially identical to that utilized for the Millstone Unit No. 2 steam generators during the 1983 and 1985 outages.
Sleeve installation will be con-ducted in accordance with NUSCO Specification SP-ME-518 and Westinghouse Report WCAP 11008 which establish that:
The upper and lower mechanical joints are qualified by o
- design, analysis and design verification testing to ensure leak tightness, pressure retaining / load carrying capability for normal and faulted design loading con-ditions, and adequate resistance to potential stress-corrosion cracking and general corrosion concerns.
o All qua'ified process / installation parameters will be monitors during installation to ensure compliance with establit.ed acceptance limits and design objectives.
o The tube sleeves are designed in accordance with ap-plicable ASME Section III requirements to ensure struc-tural adequacy of sleeves for remaining service life-time.
o The hard rolling of the bottom tube sleeve joint will not degrade the tube-to-tubesheet weld.
o The tube sleeves are sized.to minimize sleeve / tube interaction and loading on upper joint.
o The design provides for automatic and hands-on sleeve installation.
o The tube sleeve design minimizes increase to primary flow resistance.
o The structural integrity of the existing steam genera-tor tubes will not be degraded by the tube sleeve in-sta11ation.
o All sleeves are shop hydrotested in excess of 3,000 psig, in lieu of the minimum required 1,000 psig test, to ensure structural integrity and leak tightness.
Page 6 SAFETY EVALUATION CONNECTICUT YANKEE STEAM GENERATOR TUBE REPAIR o
Additional shop NDE and metallurgical inspections are implemented to ensure tube sleeve material soundness.
o The tube sleeve extends a minimum of one inch above top joint strictly to prevent a potential double-ended tube rupture.
Tubes repaired with sleeves are eddy current tested after the sleeves are installed in accordance with ASME Section XI, 1980 Edition through Winter 1980 Addenda.
This code exempts piping which is one inch and less in diameter from a system hydrostatic test.
This approach is justified because no useful information regarding the integrity of the repair will be obtained since the tubes do not pres-ently leak.
Instead, in-service. monitoring is utilized to detect leaking steam generator tubes.
The Westinghouse Sleeving Report, W, CAP 11008, also es-M tablishes that the corrosion resistance of Inconel 690 sleeves will meet or exceed that of the mill-annealed i
Ni-Cr-Fe tubes that currently exist in the Connecticut 1
Yankee steam generators.
The special thermal heat treat-ment and mechanical strength limitations recuired by the sleeve purchase specification, SP-ME-516, ensure that superior material performance is attained with respect to corrosion concerns (See Nuclear Materials and Chemistry Safety Evaluation).
C.
Proposed Change for Plugging The current plant design basis allows plugging of defec-tive steam generator tubes.
The basic structural integ-rity consideration is pressure retention under normal operating, test and postulated accident loading condi-tions.
Tubes removed from service by plug installation are ex-amined in accordance with the requirements of ASME Section XI, 1980 Edition through Winter 1980 Addenda.
This code exempts piping which is one inch and less in diameter from a system hydrostatic test.
This approach is justified because no useful information regarding the integrity of the installed plug will be obtained since the tubes do not presently leak.
Instead, in-service monitoring is util-ized to detect leaking steam generator tubes.
0 Page 7 SAFETY EVALUATION CONNECTICUT YANKEE STEAM GENERATOR TUBE REPAIR Plugs will be installed in accordance with Specification SP-ME-538.
This specification requires that the plug be designed in accordance with the original design bases and ASME Section III, 1980 Edition through Winter 1980 Adden-da.
IV.
POSTULATED FAILURES A.
Sleeved Tubes
- 1. General Repair of steam generator tubes by sleeving reduces the probability of tube rupture due to wall thinning by corrosion.
Regardless of this increase in safety, gen-eric and exceptional failures can be postulated.
These failures are reviewed with respect to effect, and pre-ventative safeguards are noted.
- 2. Generic Postulated Failures The most serious safety implications arise from generic failures.
Incorrect sleeve installation or design could result in an accident equivalent to a multiple tube rupture.
For example, if the sleeve joints were partially expanded and not rolled, the potential for multiple sleeve ejection would exist.
Besides the re-sulting loose parts, many defective tubes would then be exposed to the primary system fluid which could then leak into the secondary system.
Incorrect design could lead to the same result by ignoring an important load-ing condition.
Another failure involves sleeved tube leakage in excess of technical specification limits.
The worst case scenario would require plant shutdown and plugging of sleeved tubes.
Since no tubes are presently leaking I
and installed sleeves will not degrade present perform-ance, there is no immediate concern for this problem.
s Long term there is a small likelihood that excessive leakage will occur.,
In this event a forced outage would be necessary to plug leaking tubes.
This would pose no additional risk to the public.
Page 8
~
SAFETY EVALUATION CONNECTICUT YANKEE STEAM GENERATOR TUBE REPAIR _.
Because'such generic failures could have severe safety consequences, a great deal of attention has been paid to design and installation aspects of the tube repair program.
The Design bases, compliance documents and installation procedures have been reviewed in detail to assure that no generic'. failures will occur.
Northeast Utilities Quality Assurance Plan will be'used to assure that sleeves are fabricated and designed correctly.
Thus, these type of generic failures are essentially precluded.
- 3. Exceptional Postulated Failures These failures are ones which would not occur to all the sleeves, but would be unique to a specific sleeve.
This would include a single fabrication defect or incorrect installation.
Single sleeve ejection with a tube rupture is the worst postulated failure.
Safeguards for exceptional failures are multiple in-spections for both as-fabricated and as-installed sleeves.
Every sleeve is inspected during fabrication b'y non-destructive means (visual, dimensional, ultra-sonic, hydrostatic and eddy current).
Destructive examinations are performed on laboratory mock-ups en a sampling basis.
Visual inspections for shipping damage are performed at the site.
After installation, every i
sleeved tube is eddy current tested and the results are l
checked by vendor and Northeast Utilities Quality Con-(
' trol.
B.
Plunged Tubes l
1.' General l
l Although the proposed plugging meets or exceeds the l
current mechanical design bases, failures were postu-l lated andtheir consequences considered.
This was done l
to focus attention on those aspects of this change which potentially have the most serious safety implica-tions and to show the safeguards against these fail-urGs.
I l
Page 9 SAFETY EVALUATION CONNECTICUT YANKEE STEAM GENERATOR TUBE REPAIR The failures are grouped into two classes:
generic and exceptional.
Classes of outcomes'are then reviewed and safeguards noted.
Overall, safety is provided by care-ful, thorough design, personnel training, installation procedure
- controls, operating experience, and in-service radiation monitoring which would detect leaking tubes.
The Northeast Utilities Quality Assurance plan applies throughout the plugging design, installation and testing process.
- 2. Generic Postulated Failures The most serious safety implications arise from generic failures.
Incorrect plug installation or design could lead to an accident equivalent to a multiple tube rup-ture.
For example, if the plug expander were not pulled sufficiently, the potential for multiple plug ejection would exist.
Besides the resulting loose parts, many defective tubes would then be exposed to the primary system which could then leak into the secondary system.
Incorrect design could lead to the same result by ignoring an important loading condition.
Because such generic failures could have severe safety consequences, a great deal of attention has been paid to these aspects of plugging.
The design bases, com-pliance documents anc installation procedures have been reviewed repeatedly to assure that no generic failures will occur.
Northeast Utilities Quality Assurance plan is invoked to assure that plugs are fabricated and designed correctly.
Vendor and Northeast Utilities Quality Control will assure that plugs are installed correctly.
Thus, these types of generic failures are essentially precluded.
Another type of failure is if the corrosion phenomenon
/
responsible for plugging continued to the extent that a guillotine tube rupture occurs.
The worst case scen-ario would be a whipping or vibrating tube end that damages adjacent tubes.- Resultant leakage in excess of 1
plant limits would require an unscheduled shutdown to plug adjacent tubes and pull the fractured tube from the steam generator.
i o
Page 10 SAPETY EVALUATION CONNECTICUT YANKEE STEAM GENERATOR TUBE REPAIR
- 3. Exceptional Postulat'ed Failures These failures are ones which would not occur to all the plugs but would be unique to a specific plug.
This would include a single fabrication defect or incorrect installation.
Single plug ejection with a tube rupture is the worst postulated failure.
Safeguards for exceptional failures include multiple inspections during fabrication and installation verifi-cation controls.
Every plug is visually and dimension-ally inspected at fabrication.
Visual inspections for shipping damage are performed at the site.
Installa-tion is procedurally controlled to assure correct plug location and expansion.
V.
UNREVIEWED SAFETY OUESTION DETERMINATION The Connecticut Yankee steam generator repair program meets the original design bases as modified by the proposed change to the Safety Technical Specification and Safety Analysis.
In addition, the repair program and design criteria meet the requirements of ASME Section III, ASME Section XI, and other analytical reports to assure that the safety of the primary coolant system is not compromised.
The repair program has been further reviewed with respect to the criteria set forth in 10CFR50.59.
This review has determined that
,the proposed change does not constitute an unreviewed safety ques-tion for the following reasons:
I a)
The sleeves are designed, manufactured and tested to the origi-nal specification in conjunction with later ASME Code require-ments; thus the probability of occurrence or the consequences of an accident or malfunction of equipment important to safety is not increased.
b)
Generic and exceptional failures are essentially precluded due to extensive review and control of each phase of the repair from sleeve design through installation; programthe possibility for an, manuf acture
- thus, accident or malfunction of a type different than previously evaluated is not created.
\\
Page 11 SAFETY EVALUATION CONNECTICUT YANKEE STEAM GENERATOR TUBE REPAIR c)
Repaired steam generators restore the original safety margin for minimum wall thickness of the steam generator tubes; thus, the margin of safety is not reduced.
References:
1)
NUSCO Correspondence, J.
F. Opeka to C.
I. Grimes, December 11, 1985.
2)
Westinghouse Report, "WCAP 11008, Connecticut Yankee Steam Generator Sleeving Report (Me,chanical Sleeves), January 1986.
3)
NUSCO Internal Memo, W. B. O.'Connell to M.
R. Galler, 10/21/85.
/ /3!((
PREPARED BY:
[
DATE M. R. Galler I
/
/!/ 7[ b APPROVED BY:
DATE y.Ely /
J.
I-Ih8[o REVIEWED BY:
4 DATE M.
Kupinski REVIEWED BY:
\\
DATE k-l O[
E. A. DeBarba
!66 REVIEWED BY:
DATE
/
Gr. L. Jo h6sorV
/
MRG:beb 12/23/85 3.43
~~
- - - _ _ _ - - _ _ - _ _ - _ _ - _ - - _ - - - - - - - - - (27 pages total)
Sult1 ART OF CT 1986 EDDT CURRENT INSPECTION DATA 0:23 WEDt:ESD AT. MARCH 5.1986 1
9 LISTIt.'3 0F ALL TUeE FLAWS FOR STEAN GENEXATOR 84 STEAN GENERATOR ROW COLUtti LOC FLAW LOCATION FLAW HEIGHT (INCHES)
FLAW SIZE (%I DEFECT VOLTAGE 4
2 15 COLD TUBESHEET 3.3 23 0.33 4
2 24 COLD TUBESHEET 0.8 3
0.98 4
3 47 COLD TUBE 5HEET 3.2 2
4.82 4
3 57 COLD TUBESHEET 1.0 12 1.80 4
3 58 COLD TUBESHEET 0.8 2
2.70 4
4 53 COLD TUBESHEET 3.6 5
2.41 4
5 14 COLD TUBESHEET 1.3 6
3.89 4
5 24 COLD TUBESHEET 0.8 6
. 7.05 4
5 24 COLD TUBESHEET 1.4 2
5.36 4
5 24 COLD TUBESHEET 1.9 7
1.35 4
5 27 COLD TUEESHEET 2.4 18 1.61 4
5 29 COLD TUBESHEET 2.4 1.88 4
5 29 COLD TUBESHEET 3.1 2
4.54 4
5 30 COLD TUBESHEET 3.3 5
2.44 4
5 31 HOT TUBESHEET 39.4 10 1.15 4
5 31 COLD TUBESHEET 1.0 17 0.88 4
5 31 COLD TUBESHEET 3.5 2
1.19 4
5 33 COLD TUBESHEET 1.6
.22 1.73 4
5 33 COLD TUBESHEET 2.0 4
1.34 4
5 35 HOT TUBESHEET 1.7
'O 1.21 4
5 36 COLD TUBESHEET 1.2 33 0.72 4
5 37 COLD TUBESHEET 1.2 5
2.84 4
5 38 COLD TUBESHEET 0.7 11 2.77 4
5 39 COLD TUBESHEET 1.6 15 2.84 4
5 40 COLD TUBESHEET 2.7 9
2.12 4
5 41 HOT TUBESHEET 2.6 6
2.15 4
5 41 COLD TUBESHEET 3.2 5
4.61 4
5 42 COLD TUBESHEET 1.7 3
4.04 4
5 47 COLD TUBESHEET 2.1 26 1.66 4
5 49 COLD TUDESHEET 5.6 16 1.85 4
5 50 COLD TUBESHEET 4.0 23 0.84 4
5 51 COLD TUBESHEET 2.2 19 1.36 4
5 57 COLD TUBESHEET 2.5 1
3.20 4
5 58 HOT TUBESHEET 3.8 9
2.14 4
5 58 COLD TUBESHEET 1.2 1
3.38 4
5 58 COLD TUBESHEET 2.6 23 1.39 4-5 65 HOT TUBESHEET 2.2 28-1.20 4
5 67 HOT TUBESHEET 0.5 8
3.69 4
5 67 COLD TUBESHEET 0.9 18 1.74 4
5 69 COLD TUBESHEET 1.0 24 0.73 4
5 74 COLD TUBESHEET 0.9 78 0.74 4
5 76 HOT TUBESHEET 2.0 28 1.36 4
6 10 COLD TUBESHEET 4.9 6
2.03 4
6 14 COLD TUBESHEET 1.6 14 1.28 4
6 15 COLD TUeESHEET 2.4 4
1.48 4
2.83 4
3.22 4
6 19 COLD TUBESHEET 1.9 8
1.68 4
6 20 COLD TUBESHEET 1.5 9
3.46 4
6 24 COLD TUBESHEET 0.8 7
5.47 4
6 25 COLD TUBEShrET 1.2 11 3.47 4
6 28 COLD TUBESHEET 3.1 18 0.53 4
6 30 COLD TUBESHEET 3.3 5
1.67 4
6 33 HOT TUBESHEET 1.8 6
1.35
3 SUtW1ARY Of' CT If 86 EDDT CURRENT INSf'ECTION DATA 0:23 WEDtSSD AY, MARCH 5,1986 2
LISTIt:3 OF ALL TUEE FLAWS FOR STEAN GENERATOR 84 STEAN GENERATOR-RON COLtR94 LOC FLAW LOCATION FLAW HEIGHT (INCHESI FLAW SIZE (%)
DEFECT VOLTAGE 4
6 33 COLD TUBESHEET 2.7 12 0.80 4
6 36 COLD TUBESHEET 1.4 18 2.64 4
6 38 COLD TUBESHEET
!.4 13 1.90 4
6 39 COLD TUBESHEET 2.5 12 2.66 4
6 40 COLD TUBESHEET 2.9 5
2.22 4
6 41 COLD TUBESHEET 3.0 4
8.77 4
6 42 COLD TUBESHEET 1.9 12 2.81 4
6 44 COLD TUBESHEET 2.3 23 1.16 4
6 44 COLD TUBESHEET 2.7 20 0.78 4
6 47 COLD TUBESHEET 4.0 22 0.93 4
6 47 COLD TUBESHEET 4.2 12 3.15 4
6 48 COLD TUBESHEET 2.9 18 1.21 4
6 48 COLD TUBESHEET 4.7 7
1.89 4
6 50 COLD TUBESHEET 5.9-13 1.29 4
6 51 COLD TUBESHEET 3.2 13 2.07 4
6 58 COLD TUBESHEET 0.8 22 0.89 4
6 SS COLD TUBESHEET 2.1 10 2.74 4
6 61 COLD TUBESHEET 1.5 8
2.19 4
6 74 COLD TUBESHEET 0.8 27 1.85 4
6 85 COLD TUBESHEET 1.5 19 2.00 4
7 15 COLD TUBESHEET 1.9 9
1.78 4
7 15 COLD TUBESHEET 2.2 1
1.26 4
7 18 COLD TUBESHEET 1.2 3
3.53 4
7 19 COLD TUBESHEET 1.5 14 1.87 4
7 20 COLD TUBESHEET 0.7 8
2.11 4
7 33 COLD TUBESHEET 2.4 15 0.64 4
7 36 COLD TUBESHEEI 1.3 18 1.07 4
7 39 COLD TUBESHEET 1.6 5
2.69 4
7 40 COLD TUBESHEET 3.6 9 -
1.39 4
7 41 COLD TUBESHEET 3.0 11 4.57 4
7 43 COLD TUBESHEET 4.2 4
1.75 4
7 47 COLD TUBESHEET 3.4 17 1.32 4
7 48 COLD TUBESHEET 3.0 12 1.08 4
7 51 COLD TUBESHEET 2.9 17 1.42 4
7 51 COLD TUBESHEET 5.0 16 0.88 4
7 57 COLD TUDESHEET 2.7 5
2.05 4
7 65 COLD TUBESHEET 1.8 9
2.72 4
7 71 COLD TUBESHEET 1.8 17 1.63 4
7 73 COLD TUBESHEET 1.7 7
2.34 4
7 76 COLD TUBESHEET 1.5 1
2.41 4
7 77 COLD TUBESHEET 1.2 1
2.68 4
8 14 COLD TUDESHEET 1.8 32 0.59 4
8 15 COLD TUBESHEET
!.3 18 3.23 4
8 16 COLD TUBESHEET 0.7 4
3.75 4
8 16 COLD TUBESHEET 1.1 5
1.43 4
8 18 COLD TUBESHEET 3.4 3
4.36 4
8 19 COLD TUBESHEET 1.1 20 2.20 4
8 20 COLD TUDESHEET
!.3 6
1.86 4
8 21 COLD TUBESHEET 1.6 13 4.94 4
8 22 CotD TUDESHEET 1.2 4
5.15 4
8 23 COLD TUBESHEET 0.8 8
7.37 4
8 30 HOT TUBESHEET 1.5 13 0.70 4
8 36 COLD TUBESHEET 1.2 19 0.92 4
8 37 COLD TUBESHEET 1.2 29 1.04
SUrt1 ART OF CY 1986 EDDT CURRENT INSPECTION DATA 0:23 WEDHE50AY t1 ARCH So 1986 3
LISTIllG DF ALL TUSE FLAWS FOR STEAttC'ENERAT09 84 STEAM GENERATOR ROW COLUr94 LOC FLAW LOCATION FLAW HEIGHT IINCHESI FLAW SIZE 1%)
DEFECT VOLTAGE 4
8 38 COLD TUBESHEET 0.80 12 0.58 4
8 39 COLD TUEESHEET 0.80 5
2.22 4
8 41 COLD TUBESHEET 2.80 16 1.33 4
8 41 COLD TUBESHEET 3.30 6
2.23 4
8 42 COLD TUBESHEET 1.80 13 1.41 4
8 42 COLD TUBESHEET 3.20 3
3.34 4
8 43 COLD TUBESHEET 2.60 8
1.30 4
8 48 COLD TUBESHEET 3.00 22 1.32 4
8 49 HOT TUBESHEET 5.60 40 1.92 4
8 49 COLD TUBESHEET 3.00 19 1.28 4
8 50 COLD TUBESHEET 2.90 13 1.33 4
8 51 COLD TUBESHEET 3.00 12 1.14 4
8 52 COLD TUBESHEET 2.50 23 0.71 4
8 53 COLD TUBESHEET 2.80 9
1.24 4
6 57 COLD TUBESHEET 2.80 4
1.72 4
8 59 COLD TUBESHEET 2.90 9
1.85 4
8 62 COLD TUDESHEET 2.40 5
3.75 4
8 64 COLD TUBESHEET 2.50 7
1.84 4
8 65 COLD TUBESHEET 2.00 21 1.87 4
8 66 COLD TUBESHEET 1.60 26 0.97 4
8 66 COLD TUBESHEET 2.50 17 0.95 4
8 67 COLD TUBESHEET 0.90 13 1.28 4
8 69 HOT TUBESHEET 2.60 19 1.47 4
8 69 COLD TUBESHEET 1.60 5
1.58 4
8 71 COLD TUBESHEET 1.60 15 2.23 4.
8 74
. COLD TUBESHEET 1.30 1
2.99 4
8 75 COLD TUBESHEET 2.00 12 1.67 4
8 77 COLD TUBESHEET 0.60 3
1.95 4
8 79 COLD TUBESHEET 1.40 2
2.66 4
8 91 COLD TUBESHEET 2.20 12 2.23 4
9 14 COLD TUBESHEET 1.80 13 1.09 4
9 16 COLD TUBESHEET 3.70 13 1.17 4
9 17 COLD TUBESHEET 1.70 3
3.47 4
9 18 COLD TUBESHEET 1.70 3.19 4
9 19 COLD TUBESHEET
!.70 8
2.29 4
9 22 COLD TUDEStlEET 1.50 4
5.78 4
9 23 COLD TUBESHEET 1.90 22 3.28 4
9 24 COLD TUBESHEET 1.50 10 3.03 4
9 25 COLD TUBESHEET 0.60 27 2.32 4
9 27 COLD TUBESHEET 0.70 12 4.32 4
9 28 COLD TUBESHEET 3.10 37 0.67 4
9 29 COLD TUBESHEET 1.45 16 2.44 4
9 30 COLD TUBESHEET 2.90 7
0.78 4
9 31 HOT TUBESHEET 1.20 13 1.52 4
9 32 COLD TUBESHEET 0.60 2
0.77 4
9 36 COLD TUBESHEET 1.60 20 0.54 4
9 37 COLD TUBESHEET 1.30 11 2.70 4
9 38 COLD TUBESHEET 0.70 26 1.26 4
9 38 COLD TUBESHEET 1.50 3
1.64 4
9 39 COLD TUBESHEET 0.90 39 0.65 4
9 39 COLD TUBESHEET 3.20 14 1.15 4
9 40 COLD TUBESHEET 0.90 32 1.50 4
9 40 COLD TUBESHEET 2.70 9
2.60 4
9 41 COLD TUBESHEET 2.80 6
2.58
SUtt1AJY OF CT 1986 EDDT CURRENT INSPECTI0tl DATA 0:23 WEDHESDAT, MARCH 5. 1986 0
LISTItrG OF ALL TUBE FLAWS FOR STEAN GENECATOR 84 STEAN GENERATOR ROW COLUtti LOC FLAN LOCATI0tt FLAW HEIGHT IIHCHES)
FLAW SIZE 1%)
DEFECT YOLTAGE 4
9 42 COLD TUBESHEET 3.3 12 1.36 4
9 43 COLD TUBESHEET 3.6 13 1.11 4
9 43 COLD TUBESHEET 4.0 3
1.38 4
9 47 COLD TUBESHEET 2.2 22 2.00 4
9 48 HOT TUBESHEET 1.0 22 1.67 4
9 48 COLD TUBESHEET 2.4 22 2.19 4
9 49 COLD TUBESHEET 2.6 13 1.06 4
9 50 HOT TUBESHEET 2.2 16 1.14 4
9 50 COLD TUBESHEET 2.3 16 1.46 4
9 56 COLD TUBESHEET 2.0 8
1.82 4
9 57 HOT TUBESHEET 1.7 11 3.57 4
9 57 COLD TUBFSHEET 1.4 36 1.50 4
9 58 COLD TUBESHEET 1.1 9
1.93 4
9 60 HOT TUBESHEET 2.6 19 1.64 4
9 64 COLD TUBESHEET 2.5 14 1.54 4
9 65 COLD TUBESHEET 0.5 31 0.95 4
9 65 COLD TUBESHEET 2.0 18 2.61 4
9 66 COLD TUBESHEET 2.5 32 1.16 4
9 67 COLD TUBESHEET 0.8 16 2.08 4
9 67 COLD TUDESHEET 1.4 33 0.70 4
9 69 COLD TUBESHEET 2.2 16 2.68 4
9 70 COLD TUBESHEET 2.4 10 1.88 4
9 71 COLD TUBESHEET
!.2 11 3.76 4
9 72 COLD TUBESHEET
!.7 8
3.10 4
9 73 COLD TUBESHEET 2.8 15 1.13 4
9 75 COLD TUBESHEET 2.9 4
1.59 4
9 76 COLD TUBESHEET 0.5 9
1.70 4
9 77 COLD TUBESHEET 3.0 1
3.83 4
9 80 COLD TUBESHEET 2.0 6
3.27 4
9 81 COLD TUBESHEET 2.4 16 1.86 i
4 9
82 COLD TUBESHEET 1.5 2
1.32 4
9 84 COLD TUBESHEET 1.9 1
3.92 4
9 86 HOT TUBESHEET 3.7 37 1.03 4
10 16 COLD TUBESHEET 1.6 22 2.!!
4 10 17 COLD TUBESHEET 1.6 4
4.12 4
10 18 COLD TUBESHEET 1.3 7
2.02 4
10 19 COLD TUDESHEET 1.3 2
5.66 4
10 22 COLD TUDESHEET 1.3 7
6.27 4
10 23 COLD TUBESHEET 1.5 10 4.69 4
10 24 COLD TUBESHEET I.2 29 1.69 4
10 26 COLD TUBESHEET 1.9 4.
2.45 4
10 27 COLD TUBESHEET 0.9 23 3.68 4
10 28 COLD TUBESHEET 0.5 13 0.91 4
10 30 COLD TUBESHEET 2.4 16 0.66 4
10 32 HOT TUBESHEET 1.6 2
1.66 4
10 38 COLD TUBESHEET 0.9 24 0.81 4
10 40 COLD TUDESHEET 2.6 29 1.15 4
10 41 COLD TUBESHEET 0.8 24 0.95 4
10 42 COLD TUBESHEET 0.6 24 1.69 4
10 43 COLD TUDESHEET 1.0 27 0.90 4
10 47 HOT TUBESHEET 1.0 19 2.28 4
10 47 COLD TUBESHEET 1.0 15 0.84 4
10 48 HOT TUBESHEET 0.8 26 1.48 4
10 48 COLD TUBESHEET 1.5 17 1.08
9 SUt91 ART OF CY 1986 EDDY CURRENT INSPECTION DATA 0:23 WEDflESDAYo NAPCH 5, 1986 5
LISTIffG OF ALL TUBE FLAWS FOR STEAM GENEDATOR 84 STEAN GENERATOR ROW COLUt94 LOC FLAW LOCATION FLAW HEIGHT (IHCHES)
FLAW SIZE (%)
DEFECT VOLTAGE 4
10 49 COLD TUBE 5HEET 2.7 6
1.59 4
to 51 COLD TUBESHEET 2.6 18 1.36 4
10 53 COLD TUBESHEET 1.2 1.39 4
10 54 HOT '
TUBESHEET 2.6 10 0.97 4
10 54 COLD TUEESHEET 0.9 29 1.29 4
10 55 COLD TUBESHEET 1.7 19 1.09 4
10 56 COLD TUBESHEET 0.8 32 0.83 4
10 56 COLD TUBESHEET 1.2 26 2.32 4
10 57 COLD TUBESHEET 1.4 15 1.64 4
10 58 HOT TUBESHEET 1.1 1
5.96 4
10 SS COLD TUBESHEET 0.4 35 1.15 4
10 59 HOT TUBESHEET 0.4 10 1.61 4
10 59 COLD TUBESHEET 0.5 22 1.43 4
10 60 COLD TUBESHEET 0.5 31 0.92 4
10 61 COLD TUBESHEET 0.6 48 1.26 4
10 62 COLD TUDESHEET 0.5 8
2.38 4
10 63 COLD TUBESHEET 0.7 16 1.12 4
10 64 COLD TUBESHEET 1.3 15 0.75 4
10 65 COLD TUBESHEET 0.8 11 1.70 4
10 65 COLD TUBESHEET 2.1 9
3.65 4
10 66 COLD TUBESHEET 1.3 13 1.79 4
10 67 COLD TUBESHEET 0.9 21 0.82 4
10 67 COLD TUDESHEET 1.3 8
0.62 4
10 68 COLD TUBESHEET 1.6 12 2.34 4
10 69 COLD TUBESHEET 1.3 17 1.94 4
10 69 COLD TUBESHEET 2.4 11 3.03 4
10 70 COLD TUBESHEET 2.1 18 2.36 4
10 71 COLD TUBESHEET 2.3 12 1.88 4
to 72 COLD TUBESHEET 0.9 14 1.91 4
10 73 COLD TUBESHEET 2.6 11 3.44 4
10 74 HOT TUBESHEET 0.6 1
2.22 4
10 75 COLD TUBESHEET 2.7 10 2.36 4
10 77 COLD TUBESHEET 0.9 18 1.75 4
10 77 COLD TUBESHEET 1.4 13 1,62 4
10 79 COLD TUBESHEET 0.6 42 2.46 4
10 79 COLD TUBESHEET 3.2 34 2.77 4
10 80 COLD TUEESHEET 2.7 13 2.88 4
10 81 COLD TUBESHEET 1.3 7
1.37 4
10 82 COLD TUBESHEET 0.6 18 1.99 4
16 COLD TUBESHEET 1.5 17 2.73 4
11 17 COLD TUEESHEET 1.8 2
3.92 4
18 COLD TUBESHEET 2.1 9
4.09 4
19 COLD TUBESHEET 1.6 13 4.51 i
4 11 20 COLD TUBESHEET 3.6 13 5.43 4
21 COLD TUBESHEET 1.6 7
1.02 4
11 22 COLD TUBESHEET 1.6 8
8.05 4
23 COLD TUBESHEET 1.1 2
2.42 4
11 26 COLD TUBESHEET 0.9 39 3.11 4
11 36 COLD TUDESHEET 1.2 19 0.94 l
4 11 42 COLD TUBESHEET 0.8 20 2.22 4
11 43 COLD TUSESHEET 0.9 3
3.05 4
11 45 COLD TUDESHEET 0.8 31 1.37 4
11 47 COLD TUBESHEET 1.2 30 1.26 4
50 COLD TUBESHEET 1.2 19 0.87 i
SUP91ARY OF CY 1986 EDDY CURRENT INSFECTION GATA 0:23 WEDHESDAY. MARCH 50 3986 6
LISTING OF ALL TUBE FLAWS FOR STEAN GENERATOR 84 STEAt1 GEHERATOR ROW COLUP94 LOC FLAW LOCATION FLAW HEIGHT IINCHES)
FLAW SIZE (%I DEFECT VOLTAGE 4
11 51 COLD TUBESHEET 0.8 46 0.95 4
11 52 HOT TUBESHEET 1.0 19 2.40 4
11 53 COLD TUBESHEET 3.7 40 1.05 4
11 54 COLD TUBESHEET 0.6 35 1.45 4
55 COLD TUBESHEET 0.6 33 1.78 4
II 55 COLD TUBESHEET 1.2 12 1.51 4
56 COLD TUEESHEET 0.6 44 1.02 4
58 COLD TUBESHEET 0.9 4
1.22 4
62 COLD TUSESHEET 0.6 11 1.89 4
64 COLD TUBESHEET 0.6 17 1.81 4
11 64 COLD TUBESHEET 2.2 14 2.26 4
11 65 COLD TUBESHEET 0.6 14 2.53 4
11 65 COLD TUBESHEET 2.2 7
2.32 4
66 COLD TUBESHEET 0.8 14 1.47 4
11 66 COLD TUBESHEET 2.0 8
2.29 4
11 67 COLD TUBESHEET 0.8 23 0.63 4
11 67 COLD TUBESHEET 2.5 9
2.34 4
68 COLD TUBESHEET 0.8 25 1.29 4
11 68 COLD TUBESHEET 2.4 IS 3.77 4
11 69 COLD TUBESHEET 2.4 12 5.98 4
70 COLD TUBESHEET 1.8 17 5.26 4
71 COLD TUBLSHEET 0.7 24 2.66 4
11 72 COLD TUBESHEET 2.6 17 2.25 4
11 73 COLD TUBESHEET 0.6 13 2.63 4
11 74 COLD TUBESHEET 1.5 14 3.06 4
11 75 COLD TUBESHEET 2.1 25 0.79 4
11 76 COLD TUBESHEET 0.8 13 3.10 4
77 COLD TUBESHEET 1.3 19 1.89 4
Il 78 COLD TUBESHEET 0.0 26 3.61 4
Il 79 COLD TUBESHEET 0.8 11 1.68 4
11 80 COLD TUBESHEET 0.9 35 0.86 4
81 COLD TUBESHEET 0.5 24 1.22 4
12 16 COLD TUBESHEET 1.3 15 2.97 4
12 17 COLD TUBESHEET 1.7 7
5.44 l
4 12 18 COLD TUBESHEET 1.6 9
4.87 4
12 19 COLD TUBESHEET 1.8 8
4.96 4
12 20 COLD TUBESHEET 1.6 9
4.21 4
12 21 COLD TUCESHEET 1.3 9
4.06 4
12 22 COLD TUBESHEET 1.5 17 3.48
~4 12 23 COLD TUBESHEET 1.0 12 4.31 4
12 25 COLD TUBESHEET 0.5 26 2.57 4
12 25 COLD TUBESHEET 1.2 10 1.11 4
12 28 COLD TUBESHEET 1.1 5
1.76 j
4 12 30 COLD TUBESHEET 1.5 9
1.73 1
4 12 32 COLD TUCESHEET 1.5 8
0.80 4
12 44 HOT TUBESHEET 3.4 34 2.02 4
12 48 HOT TUBESHEET I.3 37 1.37 4
12 48 HOT TUBESHEET 2.0 22 1.26 4
12 48 COLD TUBESHEET 0.7 27 1.82 4
12 48 COLD TUBESHEET 3.4 12 1.15 4
12 49 COLD TUBESHEET 0.9 16 1.58 4
12 50 COLD TUBESHEET 0.7 19 2.87 4
12 50 COLD TUBESHEET 1.2 4
1.14 4
12 51 COLD TUBESHEET 0.6 36 0.97
SUtttARY OF CY 1986 ED0Y CURREt4T IttSPECTIcti DATA 0:23 WEDHESDAYo M MCH So 1986 7
LISTING OF ALL TUBE FLAWS FCR STEAtt GENERATOR 84 STEAtt GEHERATOR ROW COLut94 LOC FLAW LOCATI0tl FLAW HEIGHT (INCHES)
FLAW SIZE t%)
DEFECT VOLTAGE 4
12 53 COLD TUBESHEET 0.5 17 1.41 I
4 12 56 COLD TUBESHEET O.3 12 3.95 4
12 58 COLD TUBESHEET 0.6 10 0.89 4
12 59 COLD TUBESHEET 0.4 17 4.32 4
12 61 COLD TUBESHEET 0.8 19 1.24 4
12 62 COLD TUBESHEET 1.0 4
2.55 4
12 63 COLD TUBESHEET 2.1 13 1.26 4
12 64 COLD TUBESHEET 0.7 36 0.96 4
12 64 COLD TUBESHEET 2.2 12 4.89 4
12 65 COLD TUBESHEET 1.9 25 4.59 4
12 66 COLD TUBESHEET 2.0 6
4.20 4
12 67 COLD TUBESHEET 2.2 5
3.76 4
12 68 COLD TUBESHEET 2.4 10 4.90 4
12 69 COLD TUBESHEET 2.5 19 3.03 4
12 70 COLD TUBESHEET 1.0 15 1.82 4
12 71 COLD TUBESHEET 2.4 19 4.19 4
12 72 HOT TUBESHEET 2.6 21 2.30 4
12 72 COLD TUBESHEET I.3 21 1.46 4
12 72 COLD TUBESHEET 2.5 19 3.12 4
12 73 HOT IST TSP 16.6 14 0.90 4
12 73 COLD TUBESHEET 2.4 32 1.00 4
12 73 COLD TUEESHEET 2.9 12 1.76 4
12 74 COLD TUBESHEET 1.5 3
2.!!
4 12 75 COLD TUBESHEET 2.1 13 1.04 4
12 76 COLD TUBESHEET 0.9 14 2.66 4
12 77 COLD TUBESHEET 0.6 13 3.07 4
12 77 COLD TUBESHEET 1.2 8
1.47 4
12 78 COLD TUBESHEET 0.7 9
2.45 4
12 79 COLD TUBESHEET 0.8 9
3.0S 4
12 81 COLD TUBESHEET 2.1 40 0.87 4
12 82 COLD TUBESHEET 1.4 15 2.60 4
12 83 COLD TUBESHEET 2.2 18 1.72 4
12 86 COLD TUBESHEET 2.5 12 1.11 4
13 16 COLD TUBESHEET 0.5 13 2.29 4
13 17 COLD TUBESHEET 1.7 7
3.09 4
13 18 COLD TUBESHEET
!.7 10 6.50 4
13 19 COLD TUBESHEET 1.1 4
5.17 4
13 20 COLD TUBESHEET 0.9 12 2.87 4
13 20 COLD TUBESHEET 1.2 11 5.71 4
13 21 COLD TUBESHEET
!.3 6.20 4
13 22 COLD TUCESHEET 1.3 9
5.60 4
13 26 COLD TUBESHEET 1.6 6
3.85 4
13 33 COLD TUBESHEET 1.0 4
3.01 4
13 38 COLD TUEESHEET 2.1 10 0.58 4
13 43 HOT TUBESHEET 1.2
- 2 0.41 4
13 49 HOT TUBESHEET 6.7 15 2.64 4
13 49 COLD TUCESHEET 0.6 24 2.65 4
13 50 COLD TUBESHEET 0.8 21 2.76 4
13 50 COLD TUBESHEET 1.4 14 0.80 4
13 51 COLD TUBESHEET 3.1 23 0.60 4
13 52 COLD TUBESHEET 0.6 19 2.68 4
13 53 COLD TUBESHEET 0.8 26 0.74
'4 13 55 COLD TUBESHEET 0.3 17 4.07 4
13 58 HOT TUBESHEET 1.0 14 1.39
SUtt1ARY OF CY 1986 EDDY CURRENT INSPECTICH DATA 0:23 WEDNESDAY, MARCH 5,1984 8
LISTIHS OF ALL TUBE FLAWS FOR STEAtt GEHETATOR.84 STEAtt GENERATOR ROW COLUtti LOC FLAW LOCATION FLAW HEIGHT (INCHESI FLAW SIZE (%I DEFECT VOLTAGE 4
13 59 COLD TUBESHEET 0.2 8
3.59 4
13 63 COLD TUBESHEET 0.7 17' l.04 4
13 64 COLD TUBESHEET 2.1 17 3.66 4
13 65 COLD TUBESHEET 1.7 10 3.50 a
4 13 66 COLD TUBESHEET 2.1 20 6.17 4
13 67 COLD TUBESHEET 2.0 7
6.94 4'
13 68 CotD TUBESHEET 2.4 13 6.23 4
13 69 COLD TUBESHEET 2.3 11 5.33 4
13 70 COLD TUBESHEET 2.1 11 4.56 4
13 71 COLD TUBESHEET 1.0 25 1.62 4
13 72 COLD TUBESHEET 2.2 15 3.40 4
13 73 COLD TUBESHEET 0.9 15 4.40 4'
13 73 COLD TUBESHEET 2.3 12 3.62 j
4-13 74 COLD TUBESHEET 2.3 2.82 4
13 75 COLD TUBESHEET 0.8 8
2.60 4
13 76 COLD TUBESHEET 1.4 30 2.05 4
13 76 COLD TUBESHEET 2.1 19 1.41 4
13 77 COLD TUBESHEET 0.9 19 2.61 4
13 77 COLD TUBESHEET 1.8 2
1.92 4
13 78 COLD TUBESHEET 1.0 18 2.30 4
13 79 COLD TUBESHEET 0.8 19 2.62 4
13 80 COLD TUBESHEET 0.8 28 2.25 4
13 80 C0!D TUBESHEET 1.1 18 2.14 4
13 81 COLD TUBESHEET 0.6 40 2.56 4
13 82 COLD TUBESHEET 1.3 7
2.12 4
13 83 COLD TUBESHEET 0.6 19 3.30 4
13 87 COLD TUBESHEET 1.9 10 2.40 4
14 16 COLD TUBESHEET 1.3 23 2.95 4
14 17 COLD TUBESHEET 1.5 15 2.57 4'
14 17 COLD TUBESHEET 2.0 18 0.86 4
14 18 COLD TUBESHEET 1.4 8
4.82 4
14 19 COLD TUBESHEET 1.8 10 5.35 4
14 20 COLD TUBESHEET 1.8 18 2.64 4
14 21 COLD TUBESHEET 1.5 5
2.40 4
14 23 COLD TUBESHEET 1.5 19 3.57 4
14 25 COLD TUBESHEET 1.7 22 3.57 4
14 26 COLD TUBESHEET 1.7 19 0.88 4
14 32 HOT TUBESHEET 1.4 4
1.15 4
14 40 COLD TUBESHEET 0.7 3
4.12 4
14 41 COLD TUBESHEET 3.1 6
2.95 4
14 47 COLD TUBESHEET 1.2 6
0.85 4
14 49 COLD TUBESHEET 0.8 24 1,47 4
14 51 COLD TUBESHEET 0.5 15 2.26 4
14 52 COLD TUBESHEET 81. 5 19 2.20 4
14 53 HOT TUBESHEET 0.4 11 2.56 4
14 57 COLD TUBESHEET 1.2 13 1.27 4
14 58 COLD TUBESHEET 2.7 19 1.32 4
14 59 COLD TUBESHEET 0.3 14 6.75 4
14 60 COLD TUDESHEET 1.5 22 1.28 4
14 61 COLD TUBESHEET 0.2 12 3.74 4
14 63 COLD TUBESHEET 0.2 8
2.14 4
14 64 COLD TUeESHEET 0.7 12 1.54 4
14 65 COLD TUBESHEET 0.7 7
3.87 4
14 65 COLD TUBESHEET 1.8 4
1.98
_m
~
SurmART OF CT ltS6 EDDY CURRENT INSPECTION CATA 0:23 WEDHESDAT, 31 ARCH 5,1986 9
LISTING OF ALL TUBE FLAWS FOR STEAN CENEIATOR 84 STEAM GENERATOR ROW COLUrte LOC FLAW LOCATION FLAW HEIGHT (INCHESI FLAW SIZE 1%)
DEFECT VOLTAGE 4
14 6'6 COLD TUBESHEET 1.2 22 1.37 4
14 66 COLD TUBESHEET 2.1 9
4.16 4
14 67 COLD TUBESHEET 2.2 14 4.24 4
14 68 COLD TUBESHEET 2.1 12 2.72 4
14 69 COLD TUBESHEET 2.0 32 1.05 4
14 69 COLD TUBESHEET 2.4 13-3.00 i
4 14 70 COLD TUBESHEET 0.8 26 2.82 4
14 71 COLD TUBESHEET 0.6 35 2.16 4
14 71 COLD TUBESHEET 2.2 20 2.66 4
14 72 COLD TUBESHEET 2.1 17 2.98 4
14 73 COLD TUBESHEET 2.7 16 1.15 4
14 74 HOT IST TSP 19.0 27 0.95 4
14 74 COLD TUBESHEET 0.6 18 2.11 4
14 75 COLD TUBESHEET 1.8 10 0.86 l
4 14 7o COLD TUBESHEET 1.1 38 2.68 4
14 77 COLD TUBESHEET 1.1 2
2.03 I
4 14 78 CCLD TUBESHEET 1.6 1
1.59 4
14 79 COLD TUBESHEET 1.7 15 2.46 4
14 80 COLD TUBESHEET 1.6 23 2.45 4
14 81 COLD TUBESHEET 0.6 22 2.81 4
14 82 COLD TUBESHEET 0.6 15 4.15 4
14 83 COLD TUBESHEET 0.3 24 2.20 4
15 17 COLD TUBESHEET 1.1 12 2.05 4
15 17 COLD TUBESHEET 1.9 9
0.58 4
15 18 COLD TUBESHEET 1.4 4
2.89 4
15 23 COLD TUBESHEET 1.6 13 1.23 4
15 28 COLD TUBESHEET 0.6 6
2.87 4
15 33 COLD TUBESHEET 0.6
~17 1.02 4
15 41 HOT TUBE 5HEET 1.9 86 0.20 4
15 41 HOT TUBESHEET 2.1 69 0.38 4
15 42 HOT TUBESHEET 1.2 24 1.18 4
15 42 HOT TUBESHEET 2.8 15 0.89 4
15 43 HOT TUBESHEET 1.5 60 0.50 4
15 43 HOT TUBESHEET 3.1 36 0.78
]
4 15 44 HOT TUBESHEET-2.5 34 0.67 4
15 45 HOT TUBESHEET 1.0 58 0.73 4
15 45 HOT TUBESHEET 2.2 42 1.04 4
15 46 HOT TUBESHEET 1.8 42 0.33 4
15 48 HOT TUBESHEET 0.5 43 0.63 4
15 48 HOT TUDESHEET 3.6 30 0.91 4
15 48 COLD TUBESHEET 1.2 9
1.42 l
4 15 52 HOT TUDESHEET 0.8 22 1.38 4
15 52 HOT TUBESHEET 1.8 17 0.64 4
15 53 HOT TUBESHEET 21 84 0.50 4
15 53 COLD TUBESHEET 0.3 9
2.41 4
15 60 COLD TUBESHEET 0.1 5
4.53 4
15 64 HOT TUBESHEET 2.1 17 2.28 4
15 65 COLD TUBESHEET 1.9 26 1.45 4
15 66 COLD TUBESHEET 2.0 17 4.92 4
15 67 COLD TUBESHEET 2.3 11 5.68 I
4 15 68 COLD TUBESHEET 2.2 12 5.49 4
15 69 COLD TUBESHEET 2.0 19 3.28 l
4 15 70 COLD TUBESHEET 1.2 30 1.01 l
4 15 70 COLD TUBESHEET 2.1 11 2.05
Sur91ARY DF CY 1986 EDDT CURRENT INSPECTION DATA 0:23 WEDHESDAT, ItARCH 5,1946 10 LISTIt3 0F ALL TUBE FLAWS FOR STEAf1 GENGATOR 84 STEAft GENERATOR POW COLLRN LOC FLAW LOCATION FLAW HEIGHT (IHCHESI FLAW SIZE 1%I DEFECT VOLTAGE 4
15 72 COLD TUBESHEET 1.4 27 1.29 4
15 73 COLD TUBESHEET 2.3 11 2.64 4
15 75 COLD TUBESHEET 1.1 21 3.31 4
15 76 COLD TUBESHEET 0.9 8
2.57 4
15 77 COLD TUBESHEET 1.8 19 1.05 4
15 78 COLD TUBESHEET 0.7 12 1.70 4
15 80 COLD TUBESHEET 0.9 45 0.75 4
15 81 COLD TUBESHEET 1.0 8
1.86 4
15 82 COLD TUBESHEET 1.0 16 3.39 4
15 83 COLD TUBESHEET 0.2 to 4.75 4
16 18 COLD TUBESHEET 1.4 22 1.79 4
16 24 COLD TUBESHEET 0.5 19 3.41 4
16 28 HOT TUBESHEET 1.4 6
0.55 4
16 29 COLD TUBESHEET 0.2 18 2.73 4
16 32 COLD TUEESHEET 0.6 11 0.75 4
16 36 COLD TUBESHEET 0.0 27 0.68 4
16 37 COLD TUBESHEET 1.1 20 1.13 4
16 42 COLD TUBESHEET 1.0 5
2.70 4
16 43 COLD TUBESHEET 1.1 36 1.46 4
16 44 HOT TUBESHEET 3.7 25 0.55 4
16 45 COLD TUBESHEET 0.7 7
3.78 4
16 47 HOT TUBESHEET 3.8 26 0.50
)
4 16 51 COLD TUBESHEET 0.2 2
2.44 1
4 16 56 COLD TUBESHEET 0.8 22 0.75 4
16 57 COLD TUBESHEET 1.0 4
1.14 4
16 61 HOT TUBESHEET 1.1 52 0.94 4
16 63 COLD TUBESHEET 0.6 14 0.89 3
4 16 65 COLD TUBESHEET 1.6 26 2.37 4
16 66 COLD TUBESHEET 1.9 21 1.50 j
4 16 66 COLD TUBESHEET 2.3 14 2.96 4
16 67 COLD TUBESHEET 2.0 21 1.11 4
16 67 COLD TUBESHEET 2.3 17 4.03 4
16 68 COLD TUBESHEET 2.2 15 5.14 4
16 69 COLD TUBESHEET 2.3 18 4.29 4
16 70 COLD TUBESHEET 2.2 17 3.79 4
16 71 Col 0 TUBESHEET 2.0 22 1.73 4
16 72 COLD TUBESHEET 0.9 30 1.94 4
16 72 COLD TUBESHEET 2.2 12 1.34 4
16 74 COLD TUBESHEET 1.2 29 0.82 4
16 75 COLD TUDESHEET 0.8 28 1.06 4
16 76 COLD TUBESHEET 0.8 34 3.14 4
16 77 COLD TUBESHEET 0.7 19 2.38 l
4 16 79 HOT 2ND TSP 28.8 9
4.76 l
4 16 80 COLD TUBESHEET 0.7 19 4.63 l
4 16 81 COLD TUDESHEET 0.6 36 1.5S 4
16 82 COLD TUBESHEET 0.8 16 3.25 4
16 83 COLD TUBESHEET 0.2 14 5.04 4
16 85 COLD TUBESHEET 1.5 52 0.29 4
16 85 COLD TUBESHEET 1.7 7
2.44 4
17 23 COLD TUEESHEET 1.7 19 3.93 4
17 24 COLD TUBESHEET 1.5 10 1.34 4
17 26 COLD TUBESHEET 1.2 9
2.00 4
17 29 COLD TUBESHEET 0.7 7
2.23 4
17 30 COLD TUBESHEET 0.7 11 1.82 l
l l
SUrt1 ART OF CT 1986 EDDT CURRENT INSPECTION DATA 0:23 WEDHESDAY, NaRCH 5. 1986 11 LISTIII) 0F ELL TUBE FLAWS FOR STEAN GENERATOR 84 STEAN GENERATOR ROW COLUrte LOC FLAW LOCATIDH FLAW HEIGHT (INCHESI FLAW SIZE (%)
DEFECT VOLTAGE.
4 17 31 COLD TUBESHEET 1.2 15 0.86 4
17 32 HOT TUBESHEET 1.3 7
1.88 4
17 42 HOT TUBESHEET 1.3 32 1.06 4
17 42 HOT TUBESHEET 2.7 9
1.49 4
17 43 HOT TUBESHEET 0.6 40 0.99 4
17 43 HOT TUBESHEET 1.4 18 0.86 4
17 45 COLD TUBESHEET 0.7 1
4.18 4
17 47 HOT TUBESHEET 0.9 35 1.07 1
4 17 47 HOT TUBESHEET 3.5 49 1.48 4
17 47 HOT 4TH TSP 3.0 19 0.99 4
17 47 COLD TUBESHEET 0.9 6
3.59 4
17 48 HOT TUBESHEET 3.1 42 0.86 4
17 48 HOT TUBESHEET 3.6 40 0.71 4
17 50 HOT TUBESHEET 5.7 36 1.96 4
17 51 HOT TUBESHEET 3.5 43 0.81 4
17 51 HOT TUBESHEET 5.8 29 1.97 4
17 52 HOT TUBESHEET 5.8 27 2.49 4
17 53 HOT TUBESHEET 2.8 24 0.68 4
17 54 HOT TUBESHEET 1.6 37 0.88 4
17 54 COLD TUBESHEET 0.9 14 1.15 4
17 56 HOT TUBESHEET 0.3 58 0.90 4
17 56 HOT TUBESHEET
!.6 29 0.93 4
17 57 HOT TUBESSCET 1.7 64 0.68 4
17 57 COLD TUBESHEET 1.4 14 1.16 4
17 58 HOT TUBESHEET 1.6 46 1.78 4
17 SS COLD TUDESHEET 1.1 4
1.38 4
17 63 COLD TUBESHEET 1.7 7
4.38 4
17 64 COLD TUBESHEET 1.8 20 2.10 4
17 65 COLD TUBESHEET 1.0 17 3.55 4
17 65 COLD TUBESHEET 2.1 3
3.53 4
17 66 COLD TUBESHEET 0.9 4
2.45 4
17 67 COLD TUBESHEET 2.3 26 2.57 4
17 68 COLD TUBESHEET 2.3 11 3.47 4
17 69 COLD TUBESHEET 2.3 19 3.51 4
17 70 COLD TUBESHEET 2.1 13 3.56 4
17 71 COLD TUBESHEET 1.2 32 2.61 4
17 71 COLD TUBESHEET 2.7 12 2.66 4
17 72 COLD TUBESHEET
!.0 31 2.27 4
17 72 COLD TUBESHEET 2.2 23 0.85 4
17 73 COLD TUBESHEET 1.1 28 1.56 4
17 74 COLD TUBESHEET 1.0 31 1.16 4
17 74 COLD TUBESHEET 1.2 15 0.62 4
17 75 COLD TUBESHEET 1.1 41 0.70 4
17 77 COLD TUBESHEET 0.8 12 1.42 4
17 78 COLD TUBESHEET 1.5 29 1.34 4
17 79 COLD TUDESHEET 0.0 18 3.92 4
17 81 COLD TUBESHEET 0.5 31 2.41 4
17 82 COLD TUDESHEET 0.5 13 5.61 4
17 83 COLD TUBESHEET 2.3 9
1.36 4
17 85 HOT TUBESHEET 2.5 92 4.85 4
18 29 COLD TUBESHEET 0.6 10 2.53 4
18 30 COLD TUBESHEET 0.8 4
3.13 4
IS 32 COLD TUBESHEET 0.6 6
3.18 4
18 33 HOT TUBESHEET 2.9 11 0.99
Surf 1ARY OF CY 1986 EDDY CURRENT INSPECTION CATA 0:23 WE0tIESDAY, MAICH 5,1986 12 LISTING OF ALI. TUBE FLAWS FOR STEArt CEHERATOR 80 STEArt GENERATOR ROW COLlete LOC FLAW LOCATION FLAW HEIGHT (INCHESI FLAW SIZE t%)
DEFECT VOLTAGE 4
18 35 COLD TUBESHEET 0.9 17 2.79 4
18 37 COLD TUBESHEET 0.8 16 3.41 4
IS 49 COLD TUBESHEET 1.0 19 0.63 4
18 50 COLD TUBESHEET 1.2 20 1.04 4
18 51 COLD TUBESHEET 1.6 33 1.18 i
4 18 57 COLD TUBESHEET 1.3 4
3.11 4
18 58 COLD TUBESHEET 3.1 3
2.47 4
18 59 COLD TUBESHEET 0.3 36 0.90.
4 18 59 COLD TUBESHEET 1.4 11 3.20 4
18 62 COLD TUBESHEET 0.6 15 1.82 4
18 63 COLD TUBESHEET 3.8 22 1.76 4
18 64 COLD TUBESHEET 1.8 13 3.51 4
18 65 COLD TUBESHEET 1.1 21 1.45 4
18 65 COLD TUBESHEET 1.9 12 3.50 4
18 66 COLD TUBESHEET 1.0 26 1.25 4
18 67 COLD TUBESHEET 1.3 13 2.41 4
18 68 COLD TUBESHEET 1.3 9
3.31 4
18 69 COLD TUBESHEET
!.2 14 1.74 4
18 69 COLD TUBESHEET 2.0 26 2.98 4
18 70 COLD TUBESHEET 2.2 20 2.88 4
18 71 COLD TUBESHEET 0.8 32 1.68 4
18 72 COLD TUBESHEET 1.2 25 3.66 4
18 73 COLD TUBESHEET 1.0 28 2.21 4
18 74 COLD TUBESHEET 1.1 22 3.12 4
18 75 COLD TUBESHEET 0.6 46 1.33 4-18 75 COLD TUBESHEET 1.0 19 2.46 j
4 18 75 COLD TUBESHEET 3.1 34 2.!!
4 18 77 COLD TUBESHEET 0.6 19 3.50 4
18 78 COLD TUBESHEET 0.6 6
5.34 4
18 79 COLD TUBESHEET 0.1 19 5.10 4
18 81 COLD TUBESHEET 0.0 16 8.43 4
18 82 COLD TUBESHEET 0.1 7
5.52 4
19 16 HOT TUBESHEET 40.6 16 0.66 4
19 21 COLD TUBESHEET 0.3 15 2.76 4
19 22 COLD TUBESHEET 1.5 3
4.03 4
19 23 COLD TUBESHEET 0.6 8
3.83 4
19 24 COLD TUBESHEET 0.8 19 3.23 4
19 39 HOT TUBESHEET 1.5 12 0.70 4
19 45 HOT TUBESHEET 0.5 58 0.54 4
19 49 HOT TUBESHEET 7.6 21 2.01 4
19 49 COLD TUBESHEET 1.0 12 2.17 4
19 50 COLD TUBESHEET 1.0 4
1.29 4
19 57 COLD TUBESHEET 1.3 3
3.03 4
19 59 COLD TUDESHEET 1.6 9
2.65 4
19 63 COLD TUBESHEET 0.5 24 1.56 4
19 63 COLD TUBESHEET I.8 15 2.67 4
19 64 COLD TUBESHEET 1.8 17 3.30 4
19 65 COLD TUBESHEET 0.7 16 1,68 4
19 65 COLD TUBESHEET 1.7 10 2.70 4
19 66 COLD TUBESHEET 2.0 17 2.15 4
19 67 COLD TUDESHEET 1.4 14 2.16 4
19 68 COLD TUBESHEET 2.2 10 1.88 4
19 69 COLD TUCESHEET 2.4 17 4.45 4
19 70 COLD TUBESHEET 2.0 17 3.42
SUrttART OF CT 1986 EDDT CUPRENT INSPECTION DATA 0:23 WECHESDAT, t1 ARCH 5.1986 13 LISTIt!G OF ALL TUBE FLAWS FOR STEAt1 GENERATOR 84 STEAf1 GENERATDR ROW COLUMN LOC FLAW LOCATION FLAW HEIGHT (INCHESI FLAW SIZE (%)
DEFECT VOLTAGE 4
19 71 COLD TUBESHEET 2.2 9
2.74 4
19 72 COLD TUBESHEET 1.0 21 3.52 4
19 73 COLD TUBESHEET 1.1 31 4.09 4
19 74 COLD TUBESHEET 1.1 22 1.06 4
19 75 COLD TUBESHEET 0.4 26 0.54 4
19 76 COLD TUBESHEET 1.5 21 2.43 4
19 77 COLD TUBESHEET 0.5 11 5.12 4
19 78 COLD TUBESHEET 0.3 19 5.31 4
19 78 COLD TUBESHEET 1.0 21 1.04 4
19 89 COLD TUBESHEET 7.3 2
2.29 4
20 21 COLD TUBESHEET 0.3 12 2.32 4
20 23 COLD TUBESHEET 0.5 5
2.3S 4
20 24 COLD TUBESHEET 0.4 12 2.63 4
20 25 COLD TUBESHEET 1.0 16 2.25 4
20 29 HOT TUBESHEET 1.7 2
2.11 4
to 33 CatD TUBESHEET 0.7 4
1.34 4
20 47 COLD TUBESHEET 0.7 7
1.64 4
20 48 HOT TUBESHEET 0.4 25 1.60 4
20 49 HOT TUBESHEET 6.6 39 0.76 4
20 49 COLD TUBESHEET 1.0 19 1.36 4
20 50 COLD TUBESHEET 1.1 19 1.07 4
20 52 HOT TUBESHEET 6.7 27 1.39 4
20 53 COLD TUBESHEET 0.9 6
2.24 4
20 55 COLD TUBESHEET 1.4 26 2.14 I
4 20 58 COLD TUBESHEET 1.4 6
2.14 4
20 59 COLD TUBESHEET 1.7 17 1.65 4
20 60 COLD TUBESHEET 0.8 9
2.44 4
20 63 HOT TUDESHEET 0.9 9
1.05 4
20 63 COLD TUBESHEET 1.8 4
2.95 4
20 65 COLD TUBESHEET 1.0 8
2.64 4
20 65 COLD TUBESHEET 2.1 7
2.48 4
20 66 COLD TUBESHEET 0.7 74 0.64 4
20 66 COLD TUBESHEET 2.1 17 2.39 4
20 67 COLD TUBESHEET 2.4 16 3.74 4
20 68 COLD TUBESHEET 2.4 9
3.38 4
20 69 COLD TUBESHEET 1.2 28 1.20 4
20 69 COLD TUBESHEET 2.4 20 2.94 4
20 70 COLD TUBESHEET 2.0 13 3.36 4
20 71 COLD TUBESHEET 1.1 13 2.28 4
20 72 COLD TUBESHEET 1.1 23 3.16 4
20 73 COLD TUDESHEET 0.8 27 1.81 4
20 73 COLD TUDESHEET 1.2 22 1.53 4
20 74 COLD TUBESHEET 1.5 22 1.38 4
20 75 COLD TUBESHEET 1.5 21 1.49 4
20 77 COLD TUBESHEET 0.3 18 3.77 4
20 78 COLD TUBESHEET 0.2 18 4.59 4
20 80 COLD TUBESHEET 0.4 15 2.23 4
21 17 HOT TUBESHEET 2.4 12 1.33 4
21 24 COLD TUBESHEET 1.2 4
1.92 4
21 25 COLD TUBESHEET 0.9 3
1.64 4
21 32 COLD TUDESHEET 1.4 7
1.54 4
21 35 COLD TUBESHEET 0.5 16 2.13 4
21 47 HOT TUBESHEET 1.6 30 0.42 4
21 49 HOT TUBESHEET 5.7 3S 1.02
SU MARY OF CY 1986 ED0Y CURRENT INSPECTION GATA 0:23 WEDHESDAY,t1 ARCH 5. 1986 10 LISTIlO OF ALL TUBE FLAWS FOR STEAtt GENERATOR 84 STEAtt GENERATOR ROW Coltr94 LOC FLAW LOCATION FLAW HEIGHT (INCHES 1 FLAW SIZE (%)
DEFECT VOLTAGE 4
21 49 COLD TUBESHEET 1.3 19 2.17 4
21 50 COLD TUBESHEET 1.0 18 1.60 4
21 52 COLD TUBESHEET 1.0 7
1.17 4
21 54 COLD TUBESHEET 0.9 0.74 4
21 55 COLD TUBESHEET 0.6 33 0.78 4
21 55 COLD TUBESHEET 1.5 16 1.33 4
21 56 COLD TUBESHEET 1.3 19 1.74 4
21 57 COLD TUBESHEET 0.6 10 3.53 4
21 58 HOT TUBESHEET 1.1 3
0.76 4
21 58 HOT TUBESHEET 2.0 13 0.95 4
21 58 COLD TUBESHEET 0.9 11 3.11 4
21 60 COLD TUBESilEET 1.0 7
1.44 4
21 65 COLD TUBESHEET 1.1 5
3.50 4
21 66 COLD TUBESHEET 2.1 18 2.86 4
21 69 COLD TUBESHEET 0.9 15 1.56 4
21 70 COLD TUBESHEET-0.7 17 3.81 4
21 71 COLD TUBESHEET 0.9 20 5.92 4
21 72 COLD TUBESHEET 0.9 18 3.42 4
21 74 COLD TUBESHEET 1.5 24 1.47 4
21 75 COLD TUBESHEET 1.0 4
1.72 4
21 76 HOT TUBESHEET 0.7 13 4.49 4
21 77 COLD TUBESHEET 0.2 10 4.51 4
21 80 COLD TUBESHEET 0.4 11 3.05 4
22 34 COLD TUBESHEET 1.3 3
2.18 4
22 49 COLD TUBESHEET 1.2 27 1.23 4
22 56 COLD TUBESHEET 1.5 13 3.26 4
22 57 COLD TUBESHEET 0.7 5
5.86 4
22 57 COLD TUBESHEET 1.7 25 0.%
4 22 58 COLD TUBESHEET 0.8 11 3.00 4
22 59 COLD TUBESHEET 1.6 19 2.25 4
22 60 COLD TUBESHEET 1.6 11 2.67 4
22 65 COLD TUBESHEET O.5 17 1.73 4
22 69 COLD TUBESHEET 1.5 6
1.79 4
22 70 CotD TUBESHEET 0.7 11 3.48 4
22 71 COLD TUBESHEET 0.9 24 4.90 4
22 72 C01D TUBESHEET 0.9 16 6.93 4
22 73 COLD TUBESHEET 0.8 11 4.22 4
23 24 COLD TUBESHEET 0.4 25 1.99 4
23 27 COLD TUBESHEET 0.4 16 1.87 4
23 29 COLD TUBESHEET 0.8 7
2.13 4
23 30 COLD TUBESHEET 1.0 13 1.33 4
23 31 COLD TUDESHEET 1.0 17 1.16 4
23 33 COLD TUBESHEET 0.5 23 1.22 4
23 50 COLD TUBESHEET 1.2 19 2.00 4
23 55 COLD TUBESHEET 0.7 17 1.07 4
23 56 COLD TUDESHEET 1.5 13 2.43 4
23 58 HOT TUBESHEET 1.2 5
1.39 4
23 59 COLD TUBESHEET 1.0 24 0.90 4
23 61 COLD TUBESHEET 1.8 19 0.89 4
23 62 COLD TUBESHEET 1.4 10 3.45 4
23 63 COLD TUBESHEET 1.3 15 2.04 4
23 69 COLD TUBESHEET 0.9 15 2.11 4
23 70 COLD TUBESHEET 0.9 3
3.22 4
23 71 COLD TUBESHEET 1.2 23 2.53
SurttARY OF CY IC86 ED0Y CURRENT IllSPECTICH DATA 0:2314EDilESDAY, MARCH 5,1986 15 LISTIt!'; OF ALL TUBE FLAWS FOR STEArt GENERATOR 84 STEAM GENERATOR ROW COLUtti LOC FLAW LOCATION FLAW HEIGHT IINCHESI FLAW SIZE 1%)
DEFECT VOLTAGE 4
23 72 COLD TUBESHEET 0.8 18 3.14 4
23 73 COLD TUBESHEET 0.0 35 2.27 4
23 73 COLD TUBESHEET 0.4 17 3.94 4
23 74 COLD TUBESHEET 0.5 13 4.34 4
24 27 COLD TUBESHEET 0.6 19 1.12 4
24 29 COLD TUBESHEET 2.2 17 1.52 4
24 30 COLD TUBESHEET 1.1 5
1.92 4
24 52 COLD TUBESHEET 0.4 46 2.46 4
24 53 COLD TUBESHEET 1.1 16 1.22 4
24 54 HOT TUBESHEET 0.9 17 0.84 4
24 55 COLD TUBESHEET 0.4 5
4.12 4
24 56 COLD TUBESHEET 0.9 13 3.10 4
24 57 COLD TUBESHEET 1.0 3
3.58 4
24 SS COLD TUBESHEET I.3 17 2.78 4
24 59 COLD TUBESHEET 1.5 19 2.15 4
24 60 COLD TUBESHEET
!.4 7
3.42 4
24 62 COLD TUBESHEET 1.6 13 2.87 4
24 63 HOT TUBESHEET 0.6 27 1.00 4
24 63 COLD TUBESHEET 3.5 11 2.62 4
24 63 COLD TUBESHEET 2.2 10 1.87 4
24 66 COLD TUBESHEET 1.5 19 1.38 4
24 67 COLD TUBESHEET 1.0 14 4.07 4
24 68 COLD TUBESHEET 1.0 16 2.27 4.
24 69 COLD TUBESHEET 1.0 26 2.57 4
24 70 COLD TUeESHEET 1.0 19 2.11 4
24 71 COLD TUDESHEET 0.6 28 1.04 4
24 73 COLD TUBESHEET 0.0 19 1.78 4
24 74 COLD TUBESHEET 0.2 15 5.20 4
24 92 HOT IST AVD 0.0 5
2.87 4
25 28 COLD TUBESHEET 1.1 25 1.45 4
25 29 COLD TUBESHEET 0.9 25 1.77 4
25 30 COLD TUBESHEET 2.3 16 1.74 4
25 31 COLD TUBESHEET 1.0 6
1.24 4
25 32 HOT TUBESHEET 0.6 15 0.82 4
25 32 COLD TUBESHEET 1.1 8
2.46 4
25 33 COLD TUBESHEET 0.9 12 -
0.89 4
25 40 COLD TUBESHEET 0.9 9
2.98 4
25 49 COLD TUBESHEET I.3 19 0.87 4
25 50 COLD TUBESHEET 1.5 16 1.21
'4 25 51 COLD TUBESHEET 0.5 23 1.28 4
25 52 COLD TUBESHEET 0.2 15 3.30 4
25 53 HOT TUBESHEET 1.0 26 0.72 4
25 53 COLD TUBESHEET 1.2 12 0.55 4
25 55 COLD TUBESHEET 0.8 6
3.07 4
25 56 COLD TUDESHEET 1.8 19 2.12 4
25 57 COLD TUBESHEET
!.6 1
2.36 4
25 58 COLD TUBESHEET I.5 3
4.09 4
25 59 COLD TUBESHEET 1.9 16 1.60 4
25 63 COLD TUBESHEET 0.7 18 0.85 4
25 63 COLD TUBESHEET 1.6 10 2.13 4
25 66 HOT TUBESHEET 0.6 19 1.58 4
25 67 COLD TUBESHEFT 1.0 55 1.5S 4
25 68 COLD TUBESHEET 1.2 22 2.09 4
25 69 POT TUBESHEET 0.5 31 1.88 w
-~
SuretARY OF CT 1986 EDDT CURRENT INSFECTION DATA 0:23 WEDHESDAT, NARCH 5. 1986 16 LISTIHG OF ALL TUBE FLAWS FOR STEAM GENERATOR #4 STEAM GEHERATOR POW COLUt1H LOC FLAW LCCATION_
FLAW HEIGHT (INCHESI FLAW SIZE'(~D DEFECT VOLTAGE-4 25 69 COLD TUBES 5 FEET 0.7 30 2.09 4
25 69 COLD TUBESHEET 1.8 12 1.00 4
25 70 COLD TUBESHEET 0.6 9
2.20 2$
71 HOT TUBESHEET 0.6 10 1.95 4
25 72 HOT TUBESHEET 0.5 36 0.92 4
25 73 COLD TUBESHEET 0.0 26 1.97 4
25 78 COLD TUBESHEET 0.2 38 1.98 4
25 87 HOT 3RD AVB 0.0 19 2.04 4
25 93 HOT IST AVB 0.0 1
3.93 4
25 92 HOT IST AVB O.0 1
2.67 4
26 9
HOT 4TH AVB 0.0 9
1.58 4
26 25 HOT TUBESHEET 1.8 19 1.24 4
26 28 COLD TUBESHEET 0.8 28 1.13 4.
26 29 COLD TUDESHEET 1.0 25 1.39 4
26 30 COLD TUBESHEET 1.1 9
3.41 4
26 31 COLD TUEESHEET 1.1 9
2.09 e
26 32 COLD TUBESHEET 1.4 9
1.80 4
26 33 COLD TUBESHEET 1.0 16 0.69 4
26 36 COLD TUBESHEET 0.9 11 1.36 4
26 49 COLD TUBESHEET 0.8 12 1.87 4
26 50 COLD TUBESHEET 1.5 25 0.87 4
26 51 COLD TUBESHEET 0.2 27 1.45 4
26 53 COLD TUBESHEET 1.5 11 0.76 4
26 54 COLD TUBESHEET 0.7 11 1.06 4
26 56 COLD TUBESHEET 0.8 12 2.37 4
26 57 COLD TUBESHEET 1.2 22 0.79 4
26 58 COLD TUBESHEET 1.9 7
1.50 4
26 60 COLD TUBESHEET 1.6 22 2.30 4
26 62 COLD TUBESHEET 1.5 17 1.48 4
26 62 COLD TUBESHEET 2.1 10 1.44 4
26 63 COLD TUBESHEET 1.6 21 1.50 4
26 64 COLD TUBESHEET 0.7 13 2.63 4
26 64 COLD TUBESHEET 1.5 14 1.94 4
26 65 COLD TUBESHEET 0.6 15 2.02 4
26 65 COLD TUBESHEET 1.2 21 1.40 i
4 26 66 HOT TUBESHEET 0.6 17 2.17 4
26 66 COLD TUBESHEET 0.9 48 1.02 4
26 67 COLD TUBESHEET 0.9 27 2.65 4
26 68 COLD TUEESHEET 0.7 23 1.36 4
26 69 HOT TUBESHEET 0.7 22 2.20 4
26 69 HOT TUEESHEET 2.4 18 1.79 4
26 69 COLD TUBESHEET 0.5 23 4.17 4
26 70 COLD TUBESHEET 0.5 19 3.91 4
26 71 HOT TUBESHEET 0.6 20 2.05 4
26 72 HOT TUBESHEET 0.9 18 2.14 4
26 72 COLD TUBESHEET 0.3 8
2.53 l
4 26 73 COLD TUeESHEET 0.0 20 2.74 4
26 74 COLD TUBESHEET 0.2 25 3.81 i
4 26 91 HOT 4TH A\\N3 0.0 15 1.39 4
26 92 HOT 4TH AVB 0.0 1
3.10 4
27 29 HOT TUBESHEET 0.7 5
1.95
,4 27 29 COLD TUDESHEET 1.5 14 1.44 4
27 30 COLD TUBESHEET 1.0 19 1.09 4
27 31 COLD TUBESHEET 1.2 14 1.89 i
SUtttARY OF CY 1986 EDDT CUPRENT INSPECTION DATA 0:23 WEDHESDAYo itARCH 5. 1986 17 LISTING OF ALL TUBE FLAWS FOR STEAN GENE 0ATOR 84 STEAft GENERATOR ROW COLUt94 LOC FLAW LOCATION FLAW HEIGHT (INCHES)
FLAW SIZE (%)
DEFECT VOLTAGE 4
27 32 COLD TUBESHEET 1.3 2
1.89 4
27 50 COLD TUBESHEET 2.1 22 0.86 4
27 51 COLD TUBESHEET 0.5 23 2.08 4
27 51 COLD TUBESHEET 0.7 23 0.65 4
27 53 COLD TUBESHEET 0.2 33 1.26 4
27 56 COLD TUBESHEET 0.9 1
2.66 4'
27 58 COLD TUBESHEET 0.8 4
1.93 4
27 59 COLD TUBESHEET 1.9 17 1,47 4
27 61 COLD TUBESHEET 1.6 6
3.65 4
27 63 COLD TUBESHEET 1.5 9
1.38 4
27 64 COLD TUBESHEET 1.4 17 2.24 4
27 65 COLD TUBESHEET 1.3 17 1.99 4
27 66 COLD TUBESHEET 0.4 18-1.42 4*
27 66 COLD TUBESHEET 0.9 28 1.04 4
27 66 COLD TUBESHEET 1.3 17 1.84 4
27 67 HOT TUBESHEET 0.5 13 2.12 4
27 67 COLD TUBESHEET 0.7 17 2.26 4
27 68 HOT TUBESHEET 0.6 16 1.92 4
27 68 COLD TUBESHEET 0.5 26 2.77 4
27 69 HOT TUBESHEET 0.5 27 1.84 4
27 69 COLD TUDESHEET 0.4 29 2.59 4
27 70 COLD TUBESHEET 8.0 9
4.44 4
27 71 HOT TUBESHFET 0.4 18 1.81 4
27 73 COLD TUBESHEET 0.0 4
2.32 4
27 74 COLD TUBESHEET 0.2 18 2.51 4
28 35 COLD TUBESHEET 0.8 19 1.61 4
28 36 COLD TUBESHEET 0.9 12 1.30 4
28 41 CC1D TUBESHEET 1.1 6
2.51 4
28 50 CCLD TUBESHEET 0.5 19 2.09
'e 28 51 COLD TUBESHEET 0.4 25 2.41 4
28 52 COLD TUBESHEET 0.4 22 2.52 4
28 53 COLD TUDESHEET 0.4 23 1.39 4
28 54 COLD TUBESHEET 0.4 to 3.90 4
28 55 COLD TUBESHEET 0.3 39 0.89 4
28 56 COLD TUBESHEET 1.6 4
2.79 4
28 57 COLD TUBESHEET 0.6 15 0.60 4
28 57 COLD TUBESHEET 1.6 10 2.40 4
28 58 COLD TUBESHEET 1.8 1
3411 4
28 64 COLD TUBESHEET 1.4 19 2.65 4
28 65 COLD TUBESHEET 1.3 19 2.02 4
28 66 HOT TUBESHEET 0.4 31 1.37 4
28 66 COLD TUBESHEET 0.6 25 1.76 4
28 66 COLD TUBESHEET 1.1 15 2.57 4
28 67 HOT TUBESHEET 0.3 19 1.95 4
28 67 COLD TUBESHEET 0.5 24 2.34 4
28 68 HOT TUBESHEET 0.5 18 2.19 4
28 68 COLD TUBESHEET 0.6 22 2.58 4
28 69 HOT TUBESHEET 0.4 19 2.62 4
28 69 COLD TUBESHEET 0.4 20 0.58 4
28 69 COLD TUBESHEET 4.5 2
2.56 4
28 73 COLD TUBESHEET 0.1 3
2.81 4
28 78 Cold TUDESHEET 1.8 19 1.27 4
28 83 HOT 3DD AVB 0.0 19 1.67 4
28 85 HOT 4TH AVB 0.0 23 1.62 1
a g
4 m
6..4 r
l I
e e
m W
m 4-e a
m O
<ee@NN4M,N@@NNN@m4@@<NN46@mNM@e<h,@Nm<M@mee<ce@@m,NOO@
- m. @. a. m. N. @.@. m. N. m. m. @. @. @. N. m. C. o. M. a. m.@. M. @. N.,. @. @. M. m. e. a. @. m. N. S. D. N. a.,. G.,. M. C. m. M. N. @. N. G. C. N. N. O.
3u k
<mmmmNONaNammmmmmmmNNmmNmNNNN<mNmNNOOMmmmmmmNMOMM<aONm u
4 W
E b
w e
c
- i 5w m
O N
w
=
3 W
M N
N..
umSNP@NWe@mMO@MN@NOMwNOmMm4meCMWM,<NdNm&NmebOMe@NNMm<M m
m Nm umNNmuN mmNNNMmMMmmmmmmmmm emNMmmmm MNmmmmmNmm O
2ea b
t
(>
m 4
m O
wz B
U.
l M
N N
w u
a a. @ @ @ N. O. N. 4. M. @. @. N. P. N. N. <. m. m. 4 6 4. M. 4. M. e. m.,. 4. M. S. O. O. <. m. m. e. m. M. N. e. @. N. 4. G. W. m m. M. N. a. O. O. O.
maNamaa..mNm-mmmam.
a.......mm.....
mmaan.....
g, g
.<=
m
+
Ma W
b z
W-2 Weg 3 (4 a
g A
uW a0
>4 O
E Obg WOW 2
0 kkkkkkkkkb>>>b>>>HHHkkkkkkkkk MWkkkkkkkkWWkkk->
eg@
M WWWWWWWWWWWWWWWWWWWWWWWWWWWWW WWWWWWWWWWWWWWWWw ggwwwwwwwwwwwwwWmwwwwwwwWwwwwwwg e.
<<55555555555555555555555555555.gwwwwwwwwwwwwwwwwwegsg
- ~5
<555555555555555554.4<
8 mm W-WmWWWwwwWmmwwwWWmmmmmw mmWw WWWwmmmWwwWmwwww.
u~
MMBBEEBBBBEBE8888EEBEEW-- E88885:---<mE88888888888888EkMMNM BBBB Ba*B" m
mm--
B 3
m Se
+
C00000 O'000O00000000 000 O
O O
OOOOOOOOOOOOOOD u > > a a a a a a k a s a a a a a a a a a a a k a a a k a h a k k k a k a a a a a a a a a a a a a a a > >. k W C
000000000000000000000000000000000000000000000000000000 a
rzuuuuuuzuuuuuuuuuuuuusvuuzuzuzzzuzuuuuuuuuuuuuuuuzzgg Ome@@cowMM<m@NeemNNMem@@@N@@@@NmSGem@ONMemONm@@NCP4 Nam a
@@NN<memWMmmmmmm@@@@@@@@@@@@@@NGGNM<<mmmmWWe@@@@@@NNCO Ou Ge@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@eOOOOceOOOOOOce&OOOOO NNNNNNNNNNNNNNNNNNNNNNNNNuNNNNNNNMMMMMMMMMMMMMM mMMMMM 4
8 4
6 8
W e
E e.
eW
-W r
e
~
I i
l l
1 j
w o.
a E e..3..,mes<~~...mM.-~M~..m
-~musm
-~m
-~...-me-..Me<en.,< >. m. u. m. <...
e
.m n u - M
- m. m.. ~. ~. ~.... M.... < M.... ~. <. ~. M. m..... ~. ~.... < ~... u. m. m......
.e 5
<-~----~~Mumu-~---naummma-Maumn
.-Mnn-.M~<<M~--
M k
u W
z W
W a
Om n
/
8 N
E W
M N
~..
en.......
n~uman-..nnen.-m..mu
--amuMMnana--n
.<~.e,
~.
-M----
~ - -- ~
-~~
~~
-~-----u-~~-
-~
3a b
m o
Wx
,a E
M.
.... u.m.
n.M..
m.r.......m. n.
- m............ ~..... m.n. u..........
u
..o o.
..........e.-..
e g
M W
8 *
$'W-2 e.
P$
a aW a@
-4E 5 WBW E gC.
M WWWWWWWWW WWWWWWW WWW WWWW W
< < < < < 5 m E E a E"" *E m < f f f f * *5 m. E m m f f f f f f f f f E E E f. f " E E
- f f f f E f. f f f 9ffff"E"*W Ef EE*EEf en8 U E
<<<<5
<<<<<<<<<amm
<5m.E.<4<m 8
WWWWWWWWW WWWWWWW WWW WWWW W
-W 55E*EEE2988B9539*B59:E v3 EEEMaBBBEBBBE$9555M<<<A888888B9 555:
d
-~----<-uk-<M-<
g
~-<-<-<<<<
B am Ee C00000000 0000000 000 GOOD
-->--aaaaaaaaa->---aaaaaaa----------aaa--aaaa---------
h 8 EoooEoooooooooooooooooooooooEzEoocoooooooooooooooooooo o
a zzz uuuuuuuuuzzzzmuuuuuuuzz zzzzzuuuzzuuuuzazzzzzzz 4GWS-MM<mmMM.@@@@--Mmm.M.m
-a mm.Ne<<Ne,..Mm.bMbbb@@CGW
<m.embmMcMt.m.-mem.h.N.
meep.NMmW GGGGGGG4-NMM 4<.@@
.aou
....-------------NNNNNNNNNNNNNNNNNMMMMMMMMMMMMMMMMMMMM MMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM 8
k I
W E
<W
-e a
I-
o N
5 a
3 m e m < m o m m e - e < < e c e o, - - e s e c e - o m - m e n s a n m e. o m n e. w e. m e c o m e - 8 4 = =
m ms
- e. e. n.
- 4. m. m. o. w. n. e. m. m. e. m e. s. u. k. s. e. e.. m. o. e. m. e. <. m. m. m. c. o. 4. e4.. e. e
- m. m. n. m... s.. o. m. m.
w g
e e
u H
com--<nume<nn--oommmmmmwe<<m-w-w-entohm<--NNNemem-NM-m u
u w
c
=w
.J, 8w 11 tt Y
~
w M
N u..
<emmm.--o<ememmusm<ews-mem48eechema-eee8Ne-enemee<meme
>m -
m-N-
--N-m----N o
2 5
m n>
0 U
s I
p
~
- e. o. e. o. o. o. o. o. o. e. o. u. o. m. u. s. e. c. o. o. o. o. o. o. o. o. a. o. o. o. m. o. o. o. o. o. m. o. o. a. o. o. o. e. o. e. m. o. o. o. o uw w
g2<
g enoooooooooooe-o-ooooooooooooomooooo-oooooooooonoooooo nm 45"
. mg z
>tw>
2 wc4
- P*$
J
- g b
aw so wu o e owe 5
gym w
www w
w SE$$$$$sf$$$$S*EE.3ffES$$$$$$$$"I$$$$EIS$$00$fff3@$$$$6 eeE gewe<<<<<<<<<wame
<<<<<<<<<<<<<$<<<<<m<<<<<<<<<<<<<<<<<
e g
>U*
ozo" o g E *r $ E o c o - > opg e z>e,*z R >,.k A e 6.g E.> E,9 x p S,$..$. >z g a z r g w o w,K w A oE, zoo s
us m
n>m
,um,,e.mAnu
--m<>~AMmmm m m. u. m >< m
-ar m.
a 2
n< ~ _, -<->
-u-
~m, 5*
-o
>bkkk,kkekk>>>>b2 222:22,ees,->..........HW>
b
>>bb g
. e. h228 k>>w>>>>>>>k.>.>>b.,
k>
28,2
$. e.. ~.. - m e... - e s m u ~ 4
- p.,m,e, u ~- m m ~ m. e. u ~. o r r~. ~n n n.... o n - ~ m.
m ee
-nennnneee
.. - < < m.e n n n n n
~ m m e e < < <.a n s nnn
~
g Q
h < m< m< m< < m< m< m< m< m< Pt e m m m m m m m m m m m m m m m m m M M m m m m m m m M m
<<<mmmmmmmmmmmmm44 4.
4Ahr.htNemeeeeeeeeeeeee a m m
4 8
.<o E
w e
5w>a
iw
..J
.h m
N a
J mk.P..tJMNQm.
- M<Nkwh49
< DMO.mM.MN.<h@<.hNn.D%.mNk<kow&&N 9
=
$9* M. 9 9 *.
- N a 7 *, " ~ a S '1
- 4
, - - M 7.* t %'. 9 7 - =
- S M. N o.M.7 a *
- 9 " *. 9 " = 7 9 *. " =
- M-
- t *.
K 4<.N M
M..
NNMMM--Mt M.M-U k
mm m
E
.o we e
N 7
u M
N N N m m. @ N m
. M tJ S m M G,. M M M h N < fJ <. M N w M. N M N M M m. h P. M d... A <. M M N M 84 h
fJ n
NV6pwmN m
um m
M*Ne' mm we um eJ N ea M m up M
e4 e4 m
3a b
5 4
V b
U.
I<.
5 He w
E'>8 (T
p e
S g b
dag
-d E5
-ue E fhg 5 !!!!!!!!!!!!!!!!!!!!!$!!!I!!!d!!!!!!!!!!!!!!!!!!!!!!!!!
8 mm kg%ggozo%*n%7EUC o
o*gozakggE9EEDOgCgKowKkg%7ENACA777NCGUUn%7LSEE ozogokcKKKekgrkgoKgogo En <DE7G uO M 7 3. < < C M u G M 7 A 2 7 2 2 5
8 O
k k k k k k k k k k k k k > > > > > > > > > > > k k k k k k k k k k k k k k w k k k k k k k k w w w k k k e.
O 0000D00000000000000000000000000000000000000o0000000000 EEEEEEEEZZEEEEEEEE%13EEE%EEEEEEEEEEEEEEEEEZZZZZZEEEEEE 4-
~ ~ ~ ~..M M M @ M. M. M M M... N. W. S. A. N M. < < <. N. N e < < < m... e. P @ o = N, N. N. N. N. N. k ~ ~,.
N #J N M M M.
.r~~M.m.M
..,-~~k-M Ou r
WOOO...................d mMHMHH MHH mN NMMMMHHMHMNN t<<<1,<<<<<<<<<<<<<<<<<<<<<<<<<<<<NNNNNNN MMMM<<<<<<<
8>..
,44,<<<<<<<<<<<<<44,<<<<<<<<<<<<<<<<<<<<<<<
0 5
- e e
a G
9 N
te W
e o
m k
e d
44@mMam...me.
m
- m. e. =. M. b. e. a. d. N. u. m. e.. M M N N, N @. m @ @ @J M. M. P m. m. m M @ m. M N e m m m. M N P @ @ N N 4 4m. 4.
m O
. M. b. ed.
.. m. m. e. m.. m. m. m.. m.
f m m Sb
&Nmm Om 4
$$$$ N k N m N $
M $b N
.$N MM N&MN4N&
Mmm&4
$h U
k m
=
m m
h U
w e
N bw Q
k<
?
m a
u N
M N
N.
m. m m M 4 @. m k C M N P, @. m... m m G. M 4 M N G. M m e M C M N N @ N m d. N a fJ N M 4 m t m
m m
M m
m m
mmM
( m ee mmm N
m < m m N M m m m m N m N e4 x
3 m
4 m
9 M
u wz 5
8
~
C
~
e......o....................o..........................
M sg, 5 f.~.
=y EN-z w e et R
M d
5 Baw de k ts OgE o
,k
- E* * %692889N88999669988999999608989968988698899999999988
@m=
m>Q U
p mb D
kkQzQbQOkOOTOQ200kOkOzgQWOkkzgOOkQOzOQOzkMzkOkk kkzO v3 US$7CULEUM%7%G7AEURUR7mLUR$27 NEE $4E7%n%7UC72RUSuU$7%
3 3~
k M
k h k k k k k b k k k k k W h > b > k te k k k k k k k k k k k k k k k k k k k k k k k k k k k k k k k k oong zzz_EouEooooEococonoEococoEEEEocoooooooooooooooooooo E
a z=
zzzr zzzzzzz zzzzz zzzzzzzzzzzzzzzzzzzzzz
& m N, e. <.
- 4 m m..e. k. u m e4 4 N e m e n. s.. N N m e.s.es M. M. 4 m..m m. m.. h. >. N..e @ N. M M..e m s. h m. e eme t
m.
v b
M A M, M M M M,M M M M M M,M M M M 4 4 e 4 4 4 4.J.,m e m m m m m m m m m m m m m....... k N N e
= <<
444
<<<<4 E
k<
h
'44444<<<4444,4499444444,4444444444444,4,44,44<<<4444 z<
w>m a
o
SUNNARY OF ALL TUBE FLAWS 8:23 WECHESDAY, MARCH 5,1986 23 FOR CY !!S6 E00Y CURRENT INSPECTION FOR STEAM GENE;ATOR 8*4
_.....=__ __ - _
I l
STEAN l
l l
I GENERATOR I l
I 1..._
....I l
l l
4 l
TOTAL l
l l===_
_____.- __-===...I l
l LOC I
LOC I
l l........_......-
...I l
l COLO l HOT-1 COLD l HOT l l
1........__._.
...__...I I
f tRJt1BERitRJteERlifJt:BERitRJMBER l l
l OF I 0F l 0F l OF l l
IFLAWS l FLAWS IFLARS IFLAWS l l-------___
_...........___..........._....l 15IZE I
I I
i l
l---
._...l l
I l
l
__-.....=-
l<20%
1 6321 2231 6321 2231 l.........___ -- =___--- =...=-
.......... __....... _l 120-29x i
1611 511 1611 511 1........
_____--____-............................l 130-39%
i sti tal 511 281 1.........._____
_=,_..........._,_.........__.1
_ = _ _ _ _ _ -
l 121 141 121 141 1-
=- --- -
-+------+------+------+------I 150-59%
i 21 41 21 41 1.-
-.......I 160-69x i
.I 31
.I 31
- 1. -
--.......,_...................l 170-79x 1
21
.I 21
.I 1.___
__.=.===--
=______._.........,_
......-_-__.......l 18o.s9x i
.I 21
.I 21 1.. _.. ___........ _____........___
...................__.1 190-100x i
.I 11
.I 11 l.
-......................._____I ITOTAL l
e601 3261 86o1 3261
____==-__
_==---___
____=_ ___=--_ _.........
SUMMARY
OF ALL TUBE FLAWS c:23 WEDNESDAY. MARCH 5,1966 ' 24 FOR CY 1986 EDOY CURRENT INSPECTIoH FOR STEAM GENERATOR 84
===.._....._____........_ ____. ________
1 l STEAM i 1
I IGENER-1 l
l l ATOR I I
I l.
..._I I
I I 4 ITotAL i i
1._____.-
-1 I
INUMBERINUMBERI I
I or 1 0F 1 l
l FLAWS l FLAWS I l-
- ___....__... ___.I ISIZE l
l l
l__
...I l
l l<20%
i assi ass!
I.............
...........................I 120-29%
1
- 121 2 21 1.__......____
--.....................,____.I 13o-39%
l 791 701 l_______
___...............I 140-49%
l 26l 261 l---
_z _,____...
____.1 150-59%
1 61 61 l_........... _____................____.......I 160-69%
l 31 31 f....................-_--
__,.............I
[70-79%
1 21 El l__........
........_____l 180-89x 1
21 21 1.__
-.____...... _I 190-100%
i 11 11 1.....__....___.__......_____......____,...___l lioTAL i 11861 11861
____ --_=.__ __._......____....___
{
l
SUMMARY
OF MAXINUN FLAW SIZES PER SIDE PE2 TUCE 0:23 WEDHESDAY, MARCH 5.1966 25
=
a FOR CY 1985 EDDY CURRENT ICPECTION FOR STEAN GENE 3ATOR #4
.......___ ____ _____=........._ ___.__..-_ _ __ _...._-_
l l
STEAM i
l l
l GENERATOR l l
l l______--
-_l l
l l
4 l
TOTAL l
l g
....l l
l LOC l
LOC l
l g.
_=__,________.
___l l
l COLD l HOT l COLO l HOT l l
- l..........._............. l l
liR21BERllRJNEERINUNDERINUMBERl l
l OF l OF l OF l 0F i l
lFLARS l FLAWS l FLAWS IFL8HS l l
....g ISIZE I
l' l
l l
l__
....l l
l l
l l<20%
l.
5471 1571 547i 1571 l.....______..... _______........___,....__,______ ".....I l20-1905 l
1531 All 1531 411 g.........______.................._...........,_____.... __l 130-39%
l 491 241 491 241 l...._____
_,._........___l 140-49%
i 121 121 121 121
[....-
__. ____.......l 150-59%
l 21 41 21 41 l__
______........___.........,______,...___l 160-69%
l
.I 21
.1 21 l............___
........,___...l 170-79%
i 21
.1 21
.I
- g......._______________......__... _
.,__...........,__..._g 180-89%
i
.I 21
.1 21 l_......____..___..____
__,_.....l 190-100%
l
.1 11
.I 11 1......_--
- -==.............__,.... _,......,_____....... l l TOTAL l
7651 2431 7651 2431 e
4 a---
_a
+
=. o
SUMMARY
OF MAXINUM FLAW SIZES PER TUBE 0:23 NEDHESOAY. MARCH 5.1966 26 g
FOR CY 1986 ED0Y CURRENT INSPECTION FOR STEAN GENERATOR 84 l
ISTEAN l l
l lGENER-l l
l l ATOR 1 l
l l------I I
l l 4 l TOTAL l l
1...__.._____l l
IHUMBERINUMBERl l
l OF [ OF l l
IFLAWS lFLAlts l l.__
....l ISIZE I
l l
l______...
...l l
i l<20%
1 6601 6601 l==
- - __________.____...____,____....__..l 120-29%
l 1881 1881 l....
- - - = = -
....l 130-39%
l 711 711 1.___
__.........__........_l 140-49%
l 241 241 1....==
=_ ---- =.....--_______,_......
_____l 150-59%
l 61 61 1._......__......==__
._____l 160-697 l
21 21 1....
-__==.... _,...
__l 170-79%
l 21 El I................._-
_......__l 180-89%
l 21 21 l..........________.._.._____..,______,____..l 190-100%
l Il 11 l-=__
_,____..l ITOTAL l
9561 9561
===-_____= _____===___=__ _=.__............__.
9 I
e
b
'SUttiaRY OF TUBE ItIPECTIONS BY EXTENT 0:23 WE0t250 AY. MARCH 5,1966 27
==
g FOR CY 1986 ED0Y CUPRENT INSPECTIDH
. FOR STEArt GENERATOR 84
= _____------.._..........________........-
l l
STEAN l
l l
l GENERATOR l l
l g._...._..._
l l
l 4
1 TOTAL l
l g.. ________...........l l
l hut 1EER OF l Nut 1BER OF l l
lIHSPECTICilSlINSPECTI0ttSt I.....---
__l l LENGTH l
l l
l.
_._l l
l lTHRU U-BEND l
961 961 l__..-. ---- =_-.....________,...= - - _..___.___..;
l FULL LENGTH I
36691 36691 l-
........................__l l TOTAL i
37651 37651
--- =--_......._....
l l
.(42 pages total) ee.
g-g Surt1A.~;Y OF CY 1986 ED0Y CURRENT. INSPECTION D ATA 0:21 WEDHESDAY,114RCH 5 1986 1
. o LISTIG OF ALL TUBE FLAWS FOR STEAM GENETATOR 83 g
STEAM GENERATOR ROW COLLRif LOC FLAW LOCATION FLAW HEIGHT IIHCHES)
FLAW SIZE 8%I DEFECT VOLTAGE 3
3 3
COLD TUBESHEET 2.7 7
0.70 4
3 3
23 COLD TUBESHEET 0.8 5
1.55 3
3 44 HOT TUBESHEET 1.1 19 1.18 3
3 50 COLD TUBESHEET 1.3 29 0.76 3
3 51 COLD TUBESHEET 0.7 21 0.84 3
4 9
COLD TUBESHEET 0.8 4
0.9b 3
4 14 COLD TUBESHEET 0.6 7
1.40 3
4 17 COLD TUBESHEET 3.3 5
0.73 3
4 18 COLD TUBESHEET 2.2 19 0.51 3
4 IS COLD TUBESHEET 3.0 19 0.50 l
3 4
19 COLD TUBESHEET 1.4 2
1.66 3
4 19 COLD TUBESHEET 2.4 6
0.78 3
4 22 COLD TUBESHEET 1.9 17 0.35 3
4 22 COLD TUBESHEET 2.2 5
1.03 3
4 27 COLD TUBESHEET 1.1 12 0.84 3
4 33 COLD TUBESHEET 2.0 6
1.08 3
4 33 COLD TUBESHEET 2.7 4
0.39 3
4 34 COLD TUBESHEET 1.2 10 1.54 3
4 35 COLD TUBESHEET 0.9 6
1.34 3
4 37 COLD TUBE 5HEET 0.8 6
1.62 3
4 47 COLD TUBESHEET 1.5 2
1.65 3
4 48 COLD TUBESHEET 2.5 11 0.58 3
4 64 COLD TUBESHEET 1.1 11 1.14
'3 4
65 COLD TUBESHEET 1.1 12 0.94 3
4 67 COLD TUBESHEET 0.8 29 1.67 3'
4 68 COLD TUBESHEET 0.8 23 1.70 3
4 70 COLD TUBESHEET 0.6 18 0.85 3
4 77 COLD TUBESHEET 1.6 20 0.78 3
5 16 COLD TUBESHEET 1.3 6
1.85 3
5 30 COLD TUBESHEET 0.9 9
2.08 3
5 31 COLD TUBESHEET 3.1 9
1.26 1
3 5
43 COLD TUBESHEET 1.6 13 1.85 i
3 5
44 COLD TUBESHEET 1.6 5
1.23 3
5 45 COLD TUBESHEET 1.7 6
2.60 3
5 47 HOT TUBESHEET 1.6 12 5.05 3
5 50 COLD TUBESHEET 3.2 32 1.43 3
5 51 COLD TUBESHEET 1.5 22 '
O.91 3
5 51 COLD TUBESHEET 2.9 15 1.11 3
5 52 COLD TUBESHEET 1.4 12 1.01 3
5 53 COLD
.TUBESHEET 0.8 20 2.98 3
5 54 COLD TUBESHEET 0.8 14 2.17 3
5 59 COLD TUBESHEET 3.4 15 1.37 3
5 6te COLD
.TUBESHEET 1.0 6
2.73 3
5 65 COLD TUBESHEET 1.0 9
2.19 3
5 67
. COLD TUBESHEET 0.8 32 1.72 i
l 3
5 72 COLD TUCESHEET 0.3 10 0.98 l
3 5
85 COLD TUBESHEET 1.1 14 1.75 3
6 14 C0LD TUBESHEET 1.8 16 1.23 3
6 15 COLD TUBESHEET 2.2 7
2.53 3
6 19 COLD TUBESHEET 0.8 9
1.46 3
6 19 COLD TUBESHEET 2.2 4
1.97 3
6 M
COLD TUBESHEET 2.6 22 0.44 3
6 29 CCLD TUBESHEET 0.9 52 1.23 3
6 29 COLD TUBESHEET 1.0 54 1.30 w
SUMitA;Y OF CY 1986 EDDY CURRENT INSPECTION CATA 0:21 WEDtlESDAY ItARCH 5, 1986 2
o LISTIt~3 0F ALL TUBE FLAWS FOR STEAtt GENERATOR 83 STEAtt GENERATOR R0W COLUNH LOC FLAW LOCATION FLAW HEIGHT (IHCHESI FLAW SIZE (%)
DEFECT VOLTAGE 3
6 30 COLD TUBESHEET 1.1 5
1.65 k
3 6
33 COLD TUBESHEET 1.3 39 2.70 3
6 34 COLD TUBESHEET 1.2 21 1.27 3
6 37 COLD TUBESHEET 1.0 7
2.61 3
6 40 COLD TUBESHEET 1.6 10 0.65 3
6 41 COLD TUBESHEET 1.7 1
1.35 3
6 42 HOT TUBESHEET 3.1 3
1.22 3
6 42 COLD TUBESHEET 1.6 17 2.01 3
6 43 COLD TUBESHEET 1.8 26 3.39 3
6 44 COLD TUBESHEET 1.6 34 1.59 3
6 47 COLD TUBESHEET 2.2 12 3.33 3
6 50 COLD TUEESHEET 1.0 25 2.19 3
6 51 COLD TUBESHEET 1.5 16 1.37 3
6 52 COLD TUBESHEET 1.4 19 1.16 3
6 54 COLD TUBESHEET 0.9 12 5.21 3
6 55 COLD TUBESHEET 0.7 10 2.43 3
7 11 COLD TUBESHEET 2.3 15 1.31 3
7 17 COLD TUBESHEET 2.5 1
3.69 3
7 22 HOT TUBESHEET 1.7 18 3.19 3
7 22 HOT TUBESHEET 2.0 15 1.68 3
7 24 COLD TUBESHEET 1.5 8
3.34 3
7 25 COLD TUBESHEET 1.5 4
3.89 3
7 26 COLD TUBESHEET 1.5 7
3.21 3
7 27 COLD TUBESHEET 1.2 29 1.40 3
7 28 COLD TUBESHEET 1.4 23 1.69 3
7 29 COLD TUBESHEET 1.2 23 1.78 3
7 29 COLD TUBESHEET 1.6 5
1.41 3
7 30 COLD TUBESHEET 1.1 7
1.87 3
7 31 COLD TUBESHEET 1.1 3
3.29 3
7 34 COLD TUBESHEET 1.5 29 1.08 3
7 38 COLD TUBESHEET 1.5 13 3.51 3
7 39 COLD TUBESHEET 1.7 9
1.53 3
7 41 COLD TUBESHEET 1.8 3
2.85 3
7 42 ff0T TUBESHEET 0.3 8
1.42 3
7 42 COLD TUBESHEET
!.7 3
2.02 3
7 43 COLD TUBESHEET 2.6 6
1.87 3
7 49 COLD TUBESHEET 3.6 13 1.27 3
7 50 COLD TUBESHEET 1.8 13 1,74 3
7 52 COLD TUBESHEET 1.5 15 2.01 3
7 53 COLD TUBESHEET 1.6 19 2.12 3
7 54 COLD TUBESHEET 2.0 16 1.12 3
7 55 COLD TUBESHEET 1.0 8
1.52 3
7 57 COLD TUBESHEET 2.2 1
3.79 3
7 72 COLD TUBESHEET 2.2 7
1.07 3
8 15 COLD TUBESHEET 2.6 2
2.53 3
8 16 COLD TUBESHEET 2.6 1
3.15 3
8 17 COLD TUBESHEET 2.5 8
3.01 3
8 19 COLD TUBESHEET 2.2 8
2.79 3
8 21 COLO TUBESHEET 2.0 4
4.42 3
8 22 HOT TUBESHEET 3.7 13 1.02 3
8 24 COLD TUBESHEET 1.8 6
3.73 3
8 25 COLD TUBESHEET
!.9 I
2.90 3
8 26 COLD TUBESHEET 0.8 11 3.26 3
8 27 COLD TUBESHEET 1.8 11 1.49 L
s
StAttARY OF CT 1986 EDDY CURRENT INSPECTION DATA 0:21 NEDHESDAY,itARCH 5.'1986
-3 a
LISTING OF ALL TUBE FLAWS FOR STEAf1 GENE 2ATOR 83 STEAtt GENERATOR ROM COLut94 LOC FLAW LOCATICH FLAW HEIGHT (IHCHESI FLAW SIZE 1%)
DEFECT VOLTAGE 3
8 28 C0tD TUBESHEET 1.5 21 2.59 3
8 28 COLD TUBESHEET 2.1 7
1.27 I
3 8
29 COLD TUBESHEET 1.3 12 2.20 3
8 30 COLD TUBESHEET 1.5 8
0.93 3
8 31 COLD TUBESHEET 1.2 9
2.13 3
8 31 COLD.
TUBESHEET 1.9 1
1.49 3
8 32 COLD TUBESHEET 1.0 12 1.91 3
8 33 COLD TUBESHEET 1.2 11 2.57 3
8 34 COLD TUBESHEET 1.1 21 2.44 3
8 38 COLD TUBESHEET 1.3 9
5.40 3
8 39 COLD TUBESHEET 1.1 16 3.36 3
8 40 COLD TUBESHEET 1.6 12 1.66 3
8 41 COLD TUBESHEET 2.2 8
1.90 3
8 42 COLD TUBESHEET 2.1 14 3.14 3
8 43 COLD TUBESHEET 2.1 15 1.14 3
8 44 COLD TUBESHEET 2.7 9
3.01 3
8 45 COLD TUBESHEET 2.7 21 1.21 3
8 46 totD TUBESHEET 2.7 8
2.43 3
8 47 COLD TUBESHEET 2.4 15 3.39 3
8 48 COLD TUBESHEET 3.6 16 1.49 3
8 48 COLD TUBESHEET 4.4 1.45 3
8 49 COLD TUBESHEET'
-1.8 17 0.%
3 8
50 COLD TUBESHEET 1.4 40 1.04 3
8 50 COLD TUBESHEET 1.7 14 1.45 3
8 51 COLD TUBESHEET 1.5 23 1.13 3
8 52 COLD TUBESHEET 1.7 26 0.92 3
8 53 COLD TUBESHEET 1.6 15 1.10 3
8 54 COLD TUBESHEET 1.5 8
1.21 3
8 55 COLD TUBESHEET 1.6 2
3.37 3
8 56 COLD TUBESHEET 2.0 10 2.35 3
8 57 COLD-TUBESHEET 2.5 7
2.16 3
8 58 COLD TUBESHEET 1.8 12 1.30 3
8 65 COLO TUBESHEET 0.7 21 1.24 3
8 65 COLD TUBESHEET
!.0 6
1.00 3
8 69 COLD TUBESHEET 2.0 8
2.10 3
8 82 COLD TUBESHEET 1.4 11 1.05 3
8 24 COLD TUBESHEET 1.4 4
2.65 3
9 15 COLD TUBESHEET 2.7 4
1.66 3
9 16 COLD TUBESHEET 2.9 4
2.99 3
9 17 COLD TUBESHEET 3.0 8
2.02 3
9 18 COLD TUBESHEET 2.8 8
0.94 3
9 20 COLD TUBESHEET 2.0 6
4.39 3
9 21 COLD TUDESHEET 2.6 17 3.53 3
9 22 HOT TUBESHEET 2.3 17 3.61 3
9 23 COLD TUBESHEET 1.9 19 3.04 3
9 23 COLD TUBESHEET 2.4 17 1.56 3
9 24 COLD TUBESHEET 1.7 19 3.16 3
9 24 COLD TUBESHEET 2.1 16 1.40 3
9 25 COLD TUBESHEET 1.7 19 2.96 3
9 26 COLD TUBESHEET 0.8 27 2.40 3
9 27 COLD TUBESHEET 1.5 12 2.22 3
9 28 COLD TUBESHEET 1.3 13 2.08 3
9 29 COLD TUBESHEET 1.1 17 2.23 3
9 30 COLD TUBESHEET 1.9 5-3 32 u
SUtttARY OF CY 1986 ED0Y CURPENT INSPECTION CATA 0:21 WEDt4ESDAY, MARCH 5, 1986 4
a.
LISTIfG OF ALL TUEE FLAWS FOR STEAN GENCATOR 53 i
STEAtt GENERATOR ROW COLUP94 LOC FLAW LOCATION FLAW HEIGHT (INCHESI FLAW SIZE (%)
DEFECT VOLTAGE 3
9 31 COLD TUBESHEET 1.2 11 2.47 3
9 31 COLD TUEESHEET 2.0 2
2.16 3
9 32 COLD TUBESHEET 1.2 37 0.91 3
9 36 HOT TUEESHEET 0.7 2
1.15 3
9 36 COLD TUBESHEET 0.8 13 1.67 3
9 38 HOT TUEESHEET 0.5 16 1.99 3
9 39 COLD TUBESHEET 1.4 8
2.22 3
9 40 HOT TUBESHEET 0.7 10 1.53 3
9 40 COLD TUBESHEET 1.3 10 4.81 3
9 41 COLD TUBESHEET 1.3 9
2.86 3
9 42 COLD.
TUBESHEET 1.2 27 1.39 3
9 43 COLD TUBESHEET 2.0 15 1.42 3
9 45 COLD TUBESHEET 3.4 5
0.90 3
9 46 COLD TUBESHEET 1.9 12 3.05 3
9 47 COLD TUEESHEET 3.0 14 1.89 3
9 48 COLD TUBESHEET 7.2 10 1.95 3
9 50 COLD TUBESHEET 1.8 16 1.27 3
9 51 COLD TUBESHEET 1.4 25 1.35 3
9 52 COLD TUBESHEET 1.9 24 2.31 3
9 53 COLD TUBESHEET 1.9 18 1.63 3
9 54 COLD TUBESHEET 1.3 17 1.87 3
9 54 COLD TUBESHEET 1.7 3
1.48 3
9 55 COLD TUBESHEET 1.1 10 3.21 3
9 56 COLD TUBESHEET 1.8 2
3.28 3
9 58 COLD TUBESHEET 1.1 4
1.65 3
9 62 COLD TUBESHEET 0.8 19 1.28 3
9 63 COLD TUBESHEET 1.0 18 3.24 3
9 72 COLD TUBESHEET 0.5 4
2.25 3
9 73 HOT TUBESHEET 1.4 2
3.71 3
to 14 COLD TUBESHEET 2.5 4
2.38 3
10 15 COLD TUBESHEET 2.3 2
1.97 3
10 16 COLD TUBESHEET 2.2 10 1.59 3
10 16 COLD TUBESHEET 2.8 4
3.21 3
10 17 COLD TUBESHEET 2.9 10 2.55 3
10 17 COLD TUBESHEET 8.1 10 1.29 3
10 18 COLD TUBESHEET 1.6 12 2.03 3
10 19 COLD TUBESHEET 2.9 3
4.04 3
10 21 COLD TUBESHEET 2.4 13 3.13
.3 10 21 COLD TUBESHEET 3.2 19 1.22 3
10 22 COLD TUBESHEET 1.8 26 1.91 3
10 22 COLD TUBESHEET 2.3 19 3.51 3
10 23 COLD TUBESHEET 1.8 16 3.13 3
10 23 COLD TUBESHEET 2.4 22 1.23 3
10 24 COLD TUBESHEET 2.0 26 5.42 3
to 25 COLD TUBESHEET 1.5 22 2.10 3
10 25 COLD TUEESHEET 1.9 10 0.94 3
10 26 COLD TUEESHEET 0.7 24 1.34 3
10 26 COLD TUBESHEET
'0.9 6
3.34 3
10 27 COLD TUBESHEET 1.1 7
2.04 3
10 27 COLD TUBESHEET 1.4 1
2.46 3
to 28 COLD TUBESHEET 1.3 25 1.24 3
10 29 COLD TUBESHEET 1.3 40 0.30 3
10 29 COLD TUBESHEET 1.8 10 2.29 3
10 30 COLO TUBESHEET 1.2 11 1.26
SLR01ARY OF CT 1986 ED0Y CIDRENT INSPECTION DATA 0:21 WEDNESDAY. MARCH 5. 1986-5 3
LISTING OF All. TUBE FLAWS FOR STEAN GENERATOR 03 STEAN GENERATOR ROH COLUrte LOC FLAW LOCATION FLAH HEIGHT IINCHES)
FLAN SIZE (%)
DEFECT VOLTAGE-3 le 31 COLD TUBESHEET 1.9 20 1.35 3
10 33 COLD TUBESHEET 1.5 33 0.76 3
le 33 COLD TUBESHEET 3.0 2
1.64 3
10 34 COLD TUBESHEET 1.9 4
2.75 3
10 35 3
10 36
' COLD TUBESHEET 1.5 15 1.60 COLD TUBESHEET 1.2 21 1.C8 3
10 37 COLD TUBESHEET 0.7 12 1.51 3
le 38 COLD TUBESHEET 2.2 3
0.91 3
10 39 COLD TUBESHEET 1.3 10 2.10 3
10 40 HOT TUBESHEET 0.6 9
2.40 3
10 40 COLD TUBESHEET 1.5 20 1.23 3
10 41 COLD TUBESHEET 0.9 24 2.71 3
10 41 COLD TUBESHEET 2.3 3
1.20 3-10 42 COLD TUBESHEET 1.1 17 3.44 3
10 43 COLD TUBESHEET 1.5 18 1.29 3
10 45 COLD TUBESHEET 1.6 12 2.49 3
10 46 COLD TUBESHEET' 2.4 12 2.T7 3
10 47 COLD TUBESHEET
!.9 27 1.44 3
10 47 COLD TUBESHEET 2.3 14 1.63 3
10 49 COLD TUBESHEET 1.0 26 1.C0 3
10 50 COLD TUBESHEET 10.0 17 1.61 3
to 51 HOT TUBESHEET 2.7 3
1.34 3
10 51 COLD TUBESHEET 1.3 17 2.37 I
3 10 52 COLD TUBESHEET 1.6 6
2.28 3
10 53 COLD TUBESHEET 1.6 10 2.04 3
10 54 COLD TUBESHEET 1.3 13 1.06 3
10 54 COLD TUBESHEET 1.8 5
1.99 3
10 56 COLD TUBESHEET 1.1 7
1.07 3
10 58 COLD TUBESHEET
!.3 21 1.28 3
10 60 COLD TUBESHEET 1.5 6
1.14 3
10 61 COLD TUBESHEET 0.7 22 1.94 3
10 62 COLD TUBESHEET 1.0 17 4.18 3
10 63 COLD TUBESHEET 1.1 2
2.89 3
10 72 COLD TUBESHEET 0.9 2
2.35 3
10 73 COLD TUBESHEET 1.0 5
2.52 3
11 11 COLD TUBESHEET 2.8 16 2.62 3
11 14 COLD TUBESHEET 2.5 2
2.46 3
11 15 COLD TUBESHEET 2.8 12 1.49 I
3 11 16 COLD TUBESHEET 2.8 10 3.08 3
11 17 COLD TUBESHEET 2.7 13 5.59 l
3 11 18 COLD TUBESHEET 3.1 12 3.24 3
11 19 COLD TUBESHEET 2.6 8
4.64 3
i 11 21 COLD TUBESHEET 2.7 16 2.98 3
11 22 COLD TUBESHEET 2.0 20 1.36 i
3 11 22 COLD TUBESHEET 2.4 17 2.58 j
3 11 23 COLD TUBESHEET 2.8 19 1.56 j
3 11 23 COLD TUBESHEET 3.3 15 1.23 3
11 24 CDLD TUBESHEET 1.5 16 2.86 3
11 24 COLD TUBESHEET 2.0 10 1.76 ll
!"llllll?
i:'
i:n j
3 11 27 COLD TUBESHEET 1.2 12 2.86 3
11 28 COLD TUBESHEET 1.3 7
1.51
+
3 11 29 COLD TUSESHEET 1.8 4
2.92 k
SLR91ARY OF CT 1986 EDDY CURRENT INSPECTION CATA 0:21 WEDHESDAY. HARCH 5, 1986 6
e'*
LISTI Q OF ALL TUBE FLAWS FOR STEAtt GENEPATOR 83 4
STEAtt GENERATOR ROW COLLR94 LOC FLAW LOCATION FLAW HEIGHT IINCHESI FLAW SIZE (%)
DEFECT VOLTAGE 3
11 30 COLD TUBESHEET 1.4 25 1.84 3
11 31 COLD TUBESHEET 1.7 14 2.31 3
11 34 COLD TUBESHEET 3.9 5
- 1. %
3 11 36 COLD TUBESHEET 1.4 16 1.71 3
37 COLD TUBESHEET 1.5 22 1.58 3
11 39 HOT TUBESHEET 0.6 19 1.44 3'
11 40 COLD TUBESHEET 1.1 22 3.27 3
41 COLD TUBESHEET 1.6 28 0.82 i
.3 11 42 COLD TUBESHEET 1.4 24 2.64 3
i 3
11 43 COLD TUBESHEET 0.8 27 2.84 3
11 43 COLD TUBESHEET 1.7 17 2.53 3
11 44 COLD TUBESHEET 1.0 32 2.56 3
11 44 COLD TUBESHEET 1.8 29 1.83 3'
11 45 COLD TUBESHEET 2.5 to 0.70 3
11 46 COLD TUEESHEET 1.1 49 0.47 3
11 47 COLD TUBESHEET 1.1 24 1.52 1
3 11 48 COLD TUBESHEET 1.8 14 1.92 j
3 11 49 COLD TUBESHEET 0.o 21 2.72 1
3 11 50 COLD TUBESHEET 1.0 53 0.92 3
11 51 COLD TUBESHEET 1.3 9
2.59 3
11 52 COLD TUBESHEET 0.5 89
- 1. %
3 52 COLD TUBESHEET 0.6 95 1.76 3
11 52 COLD TUBESHEET 1.4 19 4.17 3
11 52 COLD TUBESHEET 1.4 21 3.84 3
11 53 COLD TUBESHEET 1.6 12 2.52 3
54 COLD TUBESHEET 1.2 3.15 3
11 55 COLD TUBESHEET 0.6 7
2.67 3
11 56 COLD TUBESHEET 1.8 5
1.84 3
11 57 COLD TUBESHEET 0.7 18 2.35 3
11 57 COLD TU3ESHEET 1.3 22 2.84 3
59 COLD TUBESHEET 0.8 13 2.73 3
11 60 COLD TUBESHEET 0.7 20 0.84 3
11 60 COLD TUBESHEET 0.9 7
2.83 3
11 61 COLD TUBESHEET 0.6 17 1.62 i
3 11 62 COLD TUBESHEET 1.6 12 1.87 3
11 66 COLD TUBESHEET 0.9 9
2.51 3
11 69 COLD TUBESHEET 0.7 9
1.80 i
3 11 69 COLD TUBESHEET 1.4 19 0.53 3
11 72 COLD TUBESHEET 0.9 18 2.04 3
73 COLD TUBESHEET 0.8 5
2.23 3
11 78 COLD TUBESHEET 1.3 8
1.61 3
12 14 COLD TUBESHEET 3.9 26 0.42 1
3 12 15 COLD TUBESHEET 2.7 15 2.51 3
2.68 3
12 16 COLD TUBESHEET 2.6 16 5.79 3
12 17 COLD TUBESHEET 2.9 17 5.47 3
12 18 COLD TUBESHEET 3.1 14 6.12 3
12 19 COLD TUBESHEET 2.9 17 5.01 3
12 21 COLD TUBESHEET 2.6 18 4.76 3
12 22 HOT TUBESHEET 4.4 12 1.04 3
12 22 COLD TUBESHEET 2.0 19 1.74 3
12 23 COLD TUBESHEET 1.8 32 1.30 3
12 23 COLD TUBESHEET 2.3 18 3.83 3
12 24 COLD TUBESHEET
!.7 22 2.99
SUMMART OF CY 1986 EDDT CURRENT INSPECTICH DATA 0:21 WE0tOSDAY, MARCH 5, 1986 7
-s LIOTItG OF ALL TUBE FLAWS FOR STEAN GENERATOR 03 STEAM GENERATOR POW COLLR94 LOC FLAW LOCATIOH FLAW HEIGHT IINCHESS FLAW SIZE (XI DEFECT VOLTAGE 3
12 24 COLD TUBESHEET 2.2 13 2.42 3
12 25 COLD TUBESHEET 1.5 15 1.85 3
12 25 COLD TUBESHEET 1.9 7
2.86 3
12 26 COLD TUBESHEET 0.6 11 2.82 3
12 26 COLD TUBESHEET 0.9 9
2.94 3
12 27 COLD TUBESHEET 1.3 19 2.12 3
12 27 COLD TUBESHEET 1.7 13 2.91 3
12 28 COLD TUBESHEET 1.4 15 3.82 3
12 28 COLD TUBESHEET 1.8 1
2.82 3
12 29 COLD TUBESHEET 1.2 27 0.81 3
12 29 COLD TUBESHEET 1.5 8
2.94 3
12 30 COLD TUBESHEET 1.7 10 4.03 3
12 31 COLD TUBESHEET 1.8 7
2.82 3
12 33 COLD TUBESHEET 1.3 14 2.77 3
12 33 COLD TUBESHEET 1.8 2
3.10 3
12 34 COLb TUBESHEET 1.3 8
2.01 3
12 34 COLD TUBESHEET 1.7 6
2.13 3
12 36 COLD TUBESHEET 1.7 17 2.95 3
12 37 COLD TUEESHEET 1.5 17 2.25 3
12 38 COLD TUBESHEET 0.6 8
1.64 3
12 39 HOT TUBESHEET 0.6 17 1.02 3
12 39 COLD TUBESHEET 2.0 7
1.80 3
12 40 COLD TUBESHEET 1.2 27 4.73 3
12 41 COLD TUBESHEET 1.5 44 0.70 3
12 41 COLD 1UBESHEET 2.1 6
1.07 3
12 42 COLD TUBESHEET 0.9 28 3.75 3
12 43 COLD TUBESHEET 0.7 27 5.11 3
12 43 COLD TUBESHEET 1.7 20 1,69 3
12 44 COLD TUBESHEEi 1.1 25 3.58 3
12 44 COLD TUBESHEET 1.9 6
2.16 3
12 45 COLD TUBESHEET 1.7 38 0.72 3
12 45 COLD TUBESHEET 2.7 15 1.07 j
3 12 46 COLD TUBESHEET 2.4 30 3.09 i
3 12 47 COLD TUBESHEET 0.9 29 1.58 3
12 47 COLD TUBESHEET 3.3 24 1.68 3
12 48 COLD TUBESHEET 1.3 26 1.44 3
12 49 COLD TUBESHEET 0.5 21 4.62 3
12 50 COLD TUBESHEET 1.1 16 2.94 3
12 51 COLD TUBESHEET 0.6 26 3.69 3
12 51 COLD TUBESHEET 1.0 28 2.24 3
12 52 COLD TUBESHEET 0.7 29 5.58 3
12 52 COLD TUBESHEET 2.2 4
1.26 3
12 53 COLD TUBESHEET 0.5 26 2.C5 3
12 54 COLD TUBESHEET 1.0 13 2.01 3
12 55 COLD TUBESHEET 0.7 14 4.76 3
12 56 COLD TUBESHEET 0.7 21 5.11 3
12 57 COLD TUBESHEET 1.3 15 2.22 3
12 59 COLD TUDESHEET 0.8 9
5.33 3
12 61 COLD TUBESHEET 0.7 17 2.51 3
12 63 COLD TUBESHEET 1.0 15 2.27 3
12 67 COLD TUBESHEET 0.9 9
1.76 3
12 70 COLD TUBESHEET 1.5 1
1.32 3
12 71 COLD TUBESHEET 0.9 18 2.71 3
12 72 COLD TUBESHEET 0.8 14 4.72
StM1 ART OF CT 1986 EDOT CURRENT INSPECTION DATA 0:21 NEDNESCAT, MARCH 5, 1986 8
LISTIt3 0F ALL TUBE FLAWS FOR STEAM SENERATOR 03 STEArt GENERATOR ROW COLLR94 LOC FLAW LOCATI34 FLAW HEIGHT IINCHESI FLAW SIZE EX)
DEFECT VOLTAGE 3
12 73 COLD TUBESHEET 0.9 18 2.58 3
13 14 COLD TUBESHEET 2.1 16-2.82 3
13 15 COLD TUBESHEET 2.3 8
3.07 3
13 16 HOT TUBESHEET 5.5 1
2.88 3
13 16 COLD
'TUBESHEET 2.5 25 6.35 3
13 17 COLD TUBESHEET 2.9 18 3.75 3
13 18 COLD TUBESHEET 2.8 15 7.89 3
13 19-COLD
.TUBESHEET 2.7 11 5.29 3
13 20 COLD TUBESHEET 2.5 19 1.48 3
13 21 COLD TUBESHEET 2.8 14 3.55 3
13 22 COLD TUBESHEET 2.0 22 1.91 3
13 23 COLD TUBESHEET 1.7 35 1.50 3
13 23 COLD TUBESHEET 3.3 12 2.%
3 13 24 COLD TUBESHEET 1.8 21 1.94 3
13 24 COLD TUBESHEET 2.3 11 1.43 3
13 25 COLD TUBESHEET 1.9 32 1.17 3
13 25 COLD TLEESHEET 2.5 25 2.58 3
13 26 COLD TUBESHEET 1.4 9
2.55 3
13 27 COLD TUBESHEET 1.1 11 1.21 3
13 27 COLD TUBESHEET 1.7 8
1.64 3
13 28 COLD TUBESHEET 1.8 17 2.93 3
13 29 COLD TUBESHEET 1.8 10 2.58 3
13 30 COLD TUBESHEET 1.8 18 4.40 3
13 31 COLD TUBESHEET 1.7 14 2.74 3
13 33 COLD TUBESHEET 0.7 27 1.33 3
13 33 COLD TUBESHEET 1.8 18 2.79 3
13 34 COLD TUBESHEET 1.4 12 2.44 3
13 35 COLD TUBESHEET 1.7 21 4.17 3
13 36 COLD TUBESHEET 1.7 21 5.07 3
13 37 COLD TUBESHEET 1.7 26 2.49 3
13 38 COLD TUBESHEET 1.4 41 0.70 3
13 38 COLD TUBESHEET 2.4 14 0.90 3
13 39 COLD TUBESHEET 2.0 7
1.63 3
13 40 COLD TUBESHEET 1.5 17 1.95 3
13 40 COLD TUBESHEET 2.2 11 1.27 3
13 41 COLD TUBESHEET 1.5 18 1.20 3
13 42 COLD TUBESHEET 0.9 23 3.29 3
13 42 COLD TUBESHEET 2.1 6
1.21 3
13 43 HOT TUBESHEET 3.6 6
3.72 3
13 43 COLD TUBESHEET 1.0 30 5.20 3
13 43 COLD TUBESHEET 1.7 25 3.59 3
13 44 COLD TUBESHEET 1.6 27 2.27 3
13 45 COLD TUBESHEET 1.3 27 5.45 3
13 46 COLD TUBESHEET 0.8 41 2.92 3
13 46 COLD TUBESHEET 1.3 18 2.73 3
13 47 COLD TUBESHEET 1.3 19 e
5.31 3
13 48 COLD TUBESHEET O.9 20 2.95 3
13 49 COLD TUBESHEET 0.7 32 3.99 3
13 49 COLD TUBESHEET 2.8 17 1.38 3
13 50 COLD TUBESHEET 1.2 27 1.53 3
13 51 COLD TU3ESHEET 0.8 38 3.91 3
13 51 COLD TUBESHEET 3.5 28 2.66 3
13 52 COLD TUBESHEET 0.7 19 5.56 3
13 53 COLD TUBESHEET 0.5 13 4.32
~-
SurftART OF CY 1986 ED0Y CURPENT INSPECTION CATA 0:21 WEDNES3AY, MARCH 5, 1986 9.
LISTItc 0F ALL TUBE FLAWS FOR STEAtt GENEYATOR C3 STEAM GENERATOR
- 0W COLT 294 LOC FLAN LOCATIDH FLAW HEIGHT IIHCHEst FLAN SIZE (%)
DEFECT VOLTAGE i
3 13 54 COLD TUBESHEET 0.9 1
2.14 3
13 55 COLD TLSESHEET 0.6 4
3.87 3
13 56 COLD TUBESHEET 3.5 9
5.57 4
3 13 57 COLD TUBESHEET 0.8 1
4.41 3
13 58 COLD TUBESHEET 0.7 9
1,46 3
13 59 COLD TUBESHEET 0.8 1
5.42 3
13 67 COLD TUBESHEET 0.5 13 1.73 3
13 69 COLD TUBE 5HEET 0.7 5
1.95 3
13 69 COLD TUBESHEET 3.0 13 1.35 3
13 71 COLD TUBESHEET 1.1 6
1.64 3
13 72 COLD TUBESHEET 0.9 10 5.57 3
13 73 COLD TUBESHEET 0.9 10
!!.07 4
3 13 74 COLD TUBESHEET 0.9 7
3.50 3
13 75 COLD TUBESHEET 0.4 29 0.48 3
13 75 COLD TUBESHEET 1.0 8
1.95 3
14 15 COLD TUBESHEET 2.3 2
2.72 3
14 16 COLD TUBESHEET 2.5 10 4.33 3
14 17 COLD TUBESHEET 2.8 22 4.60 3
14 18 COLD TUBESHEET 1.6 21 10.87 3
14 19 COLD TUBESHEET 2.6 17 6.95 i
3 14 20 COLD TUBESHEET 2.6 9
6.55 3
14 21 COLD TUBESHEET 2.1 44 1.01 3
14 21 COLD TUBESHEET 2.6 22 5.42 3
14 22 COLD TUBESHEET 2.6 22 2.73 3
14 23 COLD TUBESHEET 2.1 8
3.17 3
14 24 COLD TUBESHEET 1.7 20 2.48 3
14 24 COLD TUBESHEET 2.2 18 3.17 3
14 25 COLD TUBESHEET 2.6 11 0.86 i
3 14 26 COLD TUBESHEET 1.5 17 2.06 l
3 14 26 COLD TUBESHEET 2.1 13 3.05
]
3 14 27 COLD TUBESHEET 1.3 13 2.91 3
14 27 COLD TUBESHEET 1.9 5
1.85 3
14 28 COLD TUBESHEET 2.0 21 2.72 t
3 14 29 COLD TUBESHEET 1.9 24 2.04 3
14 30 COLD TUBESHEET 1.5 12 2.39 3
14 30 COLD TUBESHEET 1.9 8
2.29 l
3 14 31 COLD TUBESHEET 1.8 7
2.81 L
3 14 32 COLD TUBESHEET 1.3 26 1.85 3
14 32 COLD TUBESHEET 1.9 5
1.57 3
14 33 COLD TUBESHEET 1.6 19 0.90 3
14 33 COLD TUBESHEET 1.9 12 1.72 3
14 34 COLD TUBESHEET 1.2 33 2.33 J
3 14 34 COLD TUBESHEET 1.9 12 1.83 1
3 14 35 COLD TUBESHEET 1.7 11 4.14 3
14 36 COLD TUBESHEET 1.8 17 4.15 3
14 37 COLD TUBESHEET 1.5 24 1.87 3
14 38 COLD TUBESHEET 3.5 1
1.55 3
14 39 HOT TUSESHEET 0.9 27 1.31 3
14 39 COLD TUBESHEET 1.8 23 1.82 3
14 40 COLD TUBESHEET
!.5 17 2.31 3
14 41 COLD TUBESHEET 2.2 7
0.84 3
14 42 COLD TUBESHEET 1.3 22 3.34 i
3 14 43 HOT TUBESHEET 4.6 3
1.61 3
14 43 COLD TUBESHEET 1.3 34 5.79
.1
SLRetARf 0F CY 1986 ED0f CURRENT INSPECTION DATA 0:21 NEDNE50AY. MARCH 5, 1906' 30 LISTIt3 0F ALL TUBE FLAWS FOR STEAM GENE 2ATOR 83 STEAM GENERATOR ROM COLL 294 LOC FLAW LOCATION FLAM HEIGHT IIHCHESI FLAW SIZE IX)
DEFECT VOLTAGE-3 14 43 COLD TUBESHEET 4.3 5
2.44 3
14 44 COLD TUBESHEET 1.3 39 1.11 3
14 44 COLD TUBESHEET 1.6 19 3.53 3
14 45 COLD TUBESHEET 1.5 39 0.80 3
14 45 COLD TUBESHEET 2.0 10 1.75 3
14 46 COLD TUBESHEET 1.6 21 2.21 3
14 48 COLD TUBESHEET 1.0 19 1.63 3
14 48 COLD TUBESHEET 1.7 le 1.!!
3 14 49 COLD TUBESHEET 0.7 15 2.53 3
14 49 COLD TUBESHEET 0.8 6
1.78 3
14 50 COLD TUBESHEET 1.0 15 1.89 3
14 51 COLD TUBESHEET 0.7 35 3.40 3
14 52 COLD TUBESHEET 0.8 21 3.98 3
14 52 COLD TUBESHEET 1.4 9
1.63 3
14 53 COLD TUBESHEET 0.7 15 2.94 3
14 54 COLD TUBESHEET 0.6 12 4.89 3
14 54 COLD TUBESHEET 1.0 12 1.57 3
14 55 HOT TUBESHEET 0.6 53 0.67 3
14 55 COLD TUBESHEET 0.8 10 S.35 3
14 56 COLD TUBESHEET 0.8 5
5.19 3
14 57 COLD TUBESHEET 0.8 8
6.54 3
14 58 COLD TUBESHEET 0.6 2
3.40 3
14 59 COLD TUBESHEET 0.9 11 2.04 3
14 60 COLD TUBESHEET 2.8 4
2.22 3
14 61 COLD TLBESHEET 0.4 23 1.89 3~
14 68 COLD TUBESHEET 0.7 8
2.44 3
14 71 COLD TUBESHEET 1.1 6
3.26 3
14 72 COLD TUBESHEET 1.1 10 5.92 3
14 73 COLD TUBESHEET 1.0 6
5.06
'3 14 74 COLD TUBESHEET 1.1 2
4.05 3
14 83 COLD TUBESHEET 1.4 11 2.07 3
15 13 COLD TUBESHEET 1.1 16 0.70 3
15 15 COLD TUBESHEET 1.9 22 1.11 3
15 16 HOT TUBESHEET 4.1 10 1.29 3
15 16 COLD TUBESHEET 2.4 4
2.98 3
15 17 COLD TUBESHEET 2.6 11 4.22 3
15 18 COLD TUBESHEET 2.8 16 6.26 3
15 19 COLD TUBESHEET 2.6 20 7.89 3
15 20 COLD TUBESHEET 3.9 26 0.78 3
15 21 COLD TUBESHEET 2.6 to I.84 3
15 22 COLD TUBESHEET 2.0 22 2.92 3
15 22 COLD TUBESHEET 3.7 12 1.55 3
15 23 COLD TUEESHEET 3.6 20 1.20 3
15 24 COLD TUBESHEET 1.7 27 1.74 3
15 24 COLD TUBESHEET 2.1 14 4.23 3
15 25 COLD TUBESHEET 2.2 11 3.07 3
15 26 COLD TUBESHEET 2.2 9
3.41 3
15 27 COLD TUBESHEET 1.9 13 2.16 3
15 28 COLD TUBESHEET 2.1 11 2.60 3
15 29 COLD TUBESHEET 1.4 29 2.08 3
15 29 COLD TUBESHEET 1.9 le 2.65 3
15 30 COLD TUCESHEET 2.0 12 6.36 3
15 31 COLD TUBESHEET 2.0 24 2.56 3
15 32 COLD-TUBESHEET 1.9 10 1.62
SIAT1 ART OF CT 1986 EDDT CURIPEHT INSPECTION BATa 0:21 NEDHESOAY. MARCH 5. 1986 11 LI; tit 3 0F CLL TUBE FLAWS FOR STEAft GEHE 2 TOR 83 STEAft GEHERATOR ROM COLUr#4 LOC FLAM LOCATIDH FLAW HEIGHT (ItEMESI FLAW SIZE IXl DEFECT VOLTAGE 3
15 33 COLD TUBESHEET 1.60 31 0.42 3
15 33 COLD TtBESHEET 1.80 le 0.98 3
15 34 COLD TUBESHEET 1.70 24 3.94 3
15 35 COLD T12ESHEET 1.20 19 2.59
'I 3
15 36 COLD TUBESHEET 1.40 20 2.00 3
15 37 COLD TUBESHEET 1.60 8
2.78 3
15 38 COLD TUBESHEET 1.42 22 1.42 3
15 39 COLD TUBESHEET 1.90 17 3.59 3
15 41 COLD TUEESHEET 2.20 6
1.22 3
15 42 COLD TUBESHEET 1.10 17 1.07 3
15 42 COLD TUBESHEET 2.00 4
1.00 3
15 43 COLD TUBESHEET 1.30 20 2.32 3
15 44 COLD TUBESHEET 1.20 13 3.13 3
15 45 COLD TUBESHEET 1.20 9
3.38 3
15 46 COLD TUBESHEET 1.30 26 4.05 3
15 47 COLD TUBESHEET 2.20 18 2.30 3
15 45 COLD TUBESHEET 2.20 11 1.51 3
15 49 COLD TUBESHEET 1.30 13 1.40 3
15 50 COLD TUBESHEET 1.10 28 1.25 3
15 51 COLD TUBESHEET 0.90 18 3.91 3
15 52 COLD TUBESHEET 3.70 23 2.88 3
15 53 CotB TUBESHEET 3.40 12 3.22 3
15 54 COLD TUBESHEET 3.80 10 1.79 3
15 55 COLD TUBESPEET 1.00 6
6.38 3
15 56 COLD TUBESHEET 0.80 10 5.85 3
15 57 COLD TUBESHEET 3.90 9
5.21 3
15 SS COLD TUBESHEET 2.80 7
1.89 3
15 59 COLD TUBESHEET 0.90 1
3.35 3
15 62 COLD TUBESHEET 2.70 2
1.95 3
15 6S COLD TUBESHEET 3.30 3
1.87 3
15 70 COLD TUBESHEET 1.10 9
2.97 3
35 71 COLD TUBESHEET 1.40 4
7.61 3
15 72 COLD TUBESHEET 1.00 21 0.84 3
15 72 COLD TUBESHEET 1.60 4
4.68 3
15 73 COLD TLBESHEET I.30 12 4.93 3
15 74 COLD TUBESHEET 3.10 8
3.27 3
15 75 COLD TUBESHEET I.40 14 -
1.50 3
16 13 COLD TUBESHEET I.20 9
1.21 3
16 16 COLD TUBESHEET 2.00 22 0.86 3
16 16 COLD TUBESHEET 2.30 4
1.63 3
16 17 COLD TUBESHEET 2.60 15 3.73 3
16 IS COLD TUBESHEET 3.00 12 5.32 3
16 19 COLD TUEESHEET 2.60 16 7.17 3
16 20 COLD TUBESHEET 2.80 10 4.38 3
16 21 COLD TUBESHEET 2.70 29 3.77 3
16 21 COLD TUBESHEET 3.40 20 1.04 3
16 22 COLD TUBESHEET 3.90 8
2.30 3
16 23 COLD TUBESHEET 3.30 16 1.87 3
16 24 COLD TUBESHEET 1.80 24 2.11 3
16 24
. COLD TUBESHEET 2.30 21 3.38 3
16 25 COLD TUBESHEET 1.60 29 1.07 3
16 25 COLD
-TUBESHEET 3.20 9
1.35 3
16 26 COLD TUBESHEET 1.50 4
1.56 3
16 27 COLD TUBESHEET 1.60 15 3.53
N-E W.
5y gn.a.mam-.~
..--an....mame-mn
~.g m-.
ga.nu-emae~~<..
m
. 7 *. ~ ~ < <.
- a t a + =
unnummummuarm.977*=99===79797*9*.*C a9<9~7.
a~7~179a**9=
5 m-mu-~~m-~<ma
..-~r
--murr-mm-u~-~-~~~~r S
S m
w Rw a
u W
w N-
.NN~~P-mmm-
@-maNam.-< Nam.MMONasa.#.-~@..N.<Mm..P.<@<m N..
W
-~u
-m
- --- ~
m-
-mumuu Ea-0 W
G W
E 6
a U
~
.. m. e. e... 4.. m.. m.. m. e. s. e. n m u u n - ~ ~ ~ ~ ~ u - ~ ~ m - - - m. m. a... ~.. ~.. e. e. e. m. m... m. s.. e. m.. e.e. e. m. e... m. u... #..
g, g
-~~.u-.u.
.uu-m--mm-~~mun-~~m-~~-~~-
m Md*5 g
-zw-
=
"S 3
-w di
-u "8:5 8
E
$ n_ m
. m.....
..----mmmm
..........mmmmm...
-mm......
mmmm..
..m-mmmmm--m
- E m
5555555555555555555555555555555555555555555555555555 55..mmmmm m.--
8 m
mm.
m mmmmm m.
m..
83 EEBBEEEEEEEE$88888EEESSESEEEESEBBBBBBESSBB8$BSEEEBEE8E b
3*
g S99999aaS99999aS99999999999999999999999999999999999999 888888888888888888888888888888888888888888888888888888 a
l
~....-~me,amm.~~ms...-~~<<m4.~m.-~~mma...-~mmarma.~~..
J NNNNMmmmMMMmmmma<<<<<Wmmmmmmm..~~~~~~~--NNNNNNNNNNNNNN 8
........................................~~~~~~~~~~~~~~~
mm------m--m--mm---m-m--mmmm--mmm-mm----------mm-m----
8 y mmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmme 5
=
m
St# MART OF CY 1986 EDDY CURRENT INSPECTICH DATA 0:21 NEDHESDAYo NADCH 5. 1966 13
+
LISTIIG OF ALL TUBE FLAWS FOR STEAM GENERATOR 83 STEAft GENERATOR WCW COLUP94 LOC FLAM LOCATION FLAM HEIGHT (INCHESS FLAM SIZE t%)
DEFECT VOLTAGE 3
17 30 COLD TUBESHEET 2.2 14 6.50 3
17 31 COLD TUBESHEET 1.6 19 6.34 3
17 32 COLD TUBESHEET 2.0 37 1.01 3
17 32 COLD TUBESHEET 2.2 12 1.48 3
17 33 COLD TUBESHEET 1.4 15 2.32 3
17 33 COLD TUBESHEET 2.0 4
4.32 3
17 34 COLD TUBESHEET 1.5 18 3.30 3
17 34 COLD TUBESHEET 2.3 12 5.35 3
17 35 COLD TWESHEET 1.6 19 4.61 3
17 36 COLD TUBESHEET 1.5 17 1.39 3
17 37 COLD TUBESHEET 2.2 2
2.27 3
17 38 COLD TUBESHEET 2.3 9
2.05 3
17 41 HOT TUBESHEET 1.2 38 0.%
3 17 41 HOT TLElESHEET 2.2 30 0.79 3
17 41 COLD TUBESHEET 1.7 7
1.75 3
17 44 HOT TUBESHEET 1.6 32 0.55 3
17 45 COLD TUBESHEET 1.9 19 0.44 3
17 49 COLD TUBESHEET 1.2 12 1.44 3
17 52 COLD TUBESHEET 0.8 17 0.82 3
17 53 COLD TUBESHEET 0.5 7
1.63 3
17 54 COLD TUBESHEET 1.5 9
1.02 3
17 54 COLD TUBESHEET 2.7 5
1.84 3
17 55 COLD TUBESHEET 0.6 2
3.30 3
17 56 COLD TUBESHEET 0.8 5
2.40 3
17 58 COLD TUBESHEET 4.4 5
2.02 3
17 69 COLD TUBESHEET 1.6 17 5.17 3
17 70 COLD TUBESHEET 1.8 1
4.69 3
17 72 COLD TUBESHEET 1.7 7
5.14 3
17 73 COLD TUBESHEET 0.5 36 0.88 3
17 73 COLD TUBESHEET 1.8 19 2.75 3
17 77 COLD TUBESHEET 1.7 7
1.69 3
18 15 COLD TUBESHEET 0.8 4
1.29 3
18 18 COLD TUBESHEET 2.3 5
2.48 3
IS 19 COLD TUBESHEET 1.9 47 1.14 3
18 20 COLD TUBESHEET 1.9 17 2.26 3
18 20 COLD TUBESHEET 2.3 16 2.14 3
18 21 COLD TUBESHEET 1.1 14 1.07 3
18 22 COLD TUBESHEET 2.6 33 1.8i
.3 18 23 COLD TUBESHEET 2.1 24 3.73 3
18 23 COLD TUBESHEET 2.4 10 2.87 3
18 24 COLD TUBESHEET 2.3 to 3.35 3
18 24 COLD TUBESHEET 3.2 17 1.26 3
18 25 COLD TUBESHEET 2.0 23 1.34 3
18 25 COLD TUBESHEET 2.5 15 2.18 3
18 26 COLD TUBESHEET 2.5 19 3.09 3
18 27 COLD TUBESHEET 2.2 12 4.43 3
18 25 COLD TUBESHEET 2.3 18 3.81 3
18 29 COLD TUBESHEET 2.0 27 0.68 3
18 29 COLD TUBESHEET 2.4 21 2.11 3
18 30 COLD TUBESHEET 1.7 42 0.95 3
18 30 COLD TUBESHEET 2.2 10 4.14 3
18 31 COLD TUBESHEET 2.3 39 1.93 3
18 32 COLD TUBESHEET 1.5 12 2.98 3
18 33 COLD TUBESHEET 1.3 22 3.42
e O
Ym i
1 m
d N. a. r. e. f. f. m.. m. m. M. N. N. N. O.. c e - N e m e < N m e m m - N. m e m. e e - w e e r m h e O m m e m o meram.NONabNamem m
. N. m... O. N. e. h. m. m. @. M. O... d. m. O. m. b. m. O. O. M. M. N. m. O. M. O. M. m. m. m. m. m. m. m.
NSNammmfmNewNNOmmem4SMMNNmOmNm4mNNmMmm=N=dmemNmNNmN u
w bW O
4 Ry n
O N
g n
w w
N N.
ed4ddefeNedeNNNNNNddemdme.NeNeOWN.OMMMOd.mNeem.SmNeNMN m
e m
mNNm m
N mmmmm N
mN m
m mNNmmNNNNmm mNmmtm m
mN d
b m-m 4
m O
w n
~
- m. e. m. b. e. N. N.
< e. m.
N. O.
< m. e.. N. m. e. e. r.. N. o.. e. e.. O.... O. m. n. e. N. O. m. e. e. e. m. u. m. m. e. N. m. e. m.
u HmmNmNNmmmmmmmmNNOmmmmmemmmNmNmNmmNNNNNmNNumNNNNNmNmmk m
ud w
6 S
Zw-3 J
W b
JC de
>48 5 wBw 5 --------------------------------w---w---------- w-----
m wwwwwwwwwwwwwwwwwwwwwwwwwwwwwwww www wwwwwwwwwww wwww 3gm wwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwo.
U m
6 m
ow 8 wwwwwwwwwwwwwwwwwwwwwwwww wwwww wwwwwwwwwwww wwwwwwww m-v3 EBEEEEEEEBEEBBEBEEEBBEEEBBBEEBEEBBBBEEEBEEBBEBBBEBBEEM
=
m u
e d
d ed J
de e
dk Jed a
de m
O C00000000000000000000000000000000000000000000000000000 d
uuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuumuuuuuuuuuuuu
. m
( N e m 4 @ b e e n M e m e O N. e O m m N m d. M. e e m N m M d 4 m d N N.. e O O m N DA M 4 m J
mmmmmmmtf4tfmmmmmm@dedNNNNNmhammNNNNNNNNNNNNNNMMMMmmmM 8
..............................eeeeeeeeeee****eeeeeeeee mummmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmm E-4
&WC mmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmm.mm u
5 w-m
d m
I 3.ee,8me,m-~~m#e<mu..<m.me-a-~...umsu.--,#u, mame
...,m
<. e
~mummm.e
- n eumm-~n
~.....eeu.mn
<mu-m 5
aaaudauua A*aaaaaaaaaaAAdaddaaaAaaaaaAAJAdaadaaaAdaada a
u 4
w
=
0 a
'e O
Ow 5
u 8
M
~..
~~m..-
ma me.e~~<mer mmmam.....unmu~e
.-m~m.
mun<<<m
~
m uNNu-~
m--N N
N u--N-u---N--
-u-m 5am 0
m U
W
=
2
.m.e.... m..m.e.. m.s.. < s.m.. e...~...... u..... u........ ~.~.<.<.m..
.. e.u....
o
~.- un.
I,.
g g-u-~~~~~~
--u--
-~~~~~~~-munuuumunuuuu--uun-
-J
- E I
-Z - 2n3 s.Y '
a.
S 5 "B
- W E a.--
g"e.m
.w
..ww......ww.w..w......wwwwww
.....w.w.wwwwwww.wwww..w
.w-r wwwwwww.w nE 8 255555555555555555555555555555555555555555555555555555
-ww.
www m.
.w
......w
.mw-w w...
CD g
EBB $BBEEEEEEEEBEEEBEBBEEBEBB$BEBBEEB0BBBB$BBBBBEBBBBE a-
-a SSSSSS*SS*SaSSSS"S*SSS 9999*S9999999"*a99999a"S999aS99
$ 8888888888888888888888 8888888888888888888888888888888 i,
- x :::::=mun:::::::::ennuneen- ::::::e :::=====nens u
e.e..e..e. e. e.e. e e e e..e..e. e. e. e..e e.e. e.e. e e e. e e. e..e e. e. e. ~.......................
uuuuuuuuuu~~~uuuuuuuuu E-4 S
y mmmmmmemmmmmm'emmmmmmmmmmmmmmmmmmmmmmmmemememmmmmmmmmmm 5--m
r
~
s 4
2 I
s ae p
<g*egm-gggeeenneN.<emm**.Nmemm.mre.Nem.NomeNmomeNm-eme 9
.99*.
- * ~ 9 *. *. a a 9 9
- a " * *
- 1 9 9
- 9 9 9 7 9 9 = ~ = *. ~
- 7
- 9
- S *. ~ *.* S * *.
-N-NmN
.-NNmNN-mm-N-mm-mmNmNmu-N-.-N mmerNumNmmN-m-
-uw w
E 4
Rw a
.x W
WU mme mmaam-e-NamN.Nnne e-r-eNnam-me--anrNma-nemmN.merem
~
e a-u-N-N
-mr N
-m---N--------
N
-u-N----a s
3 w
n-4 m
O w
5 E
G
- m. e.. e. <.. e. n. e. m. e. e.... N.. r. e.. e. e. m. N. m. e.. e... N... <. <. e. m.. n. o.. N. a. n. e.. e.. < o. e.. n. e.
~
-NN
--.N--NNmm--m--N-m-NNaN-NNNNNN-.---HNNNNNNNmNNNNN-4.
Mw w
, wg Zw.
3 w
. w w -
aC an ou 8 5 wkw E wwwwwwwwwwwwww.wwwwwwww wwwwww
---wwwwwwwwww wwwwwwwww ge.m ww.
wwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwww wwwwwwwwwwwwwwwwwww
~5 555555555555555555555555555555555555555555555555555555 8
- mm wwwwwwwwwww.wwwwwwwwwwwwwwww www wwwwwwwwww wwwwwwwwww CD BBBEEEEEEBBEEBEEEBEEEEBEBEBEEBBEBEBEBEBEBBBBEc8EE,BBEEE 8
3 ---
b 3*
-e 99 999999-9999999999999999"S999999999999999S 99999999 0 88E000000EEuu8000000G8uuuuuu800008uuvuuuu8000000000000 00 000000 0000000 vovuuu uvuuuu uuuu vouzuuvuvuuu w
E e e.. - m o r m n e e e. - N m. e. e. n. m. e e. e.. - N m e m. ~ ~ e. N r N m a m m e n e e e e w
<<mememmmmmmm.
<nnn-unnunnnee.NNNNNuNNNNNmmmmm 8
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNedNNNNNNNNNNNNtJ B
4 I
mmmmmmmmemmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmme y
Ew>m
. +
8 e
n J
E" $N77,=7a4,.m.~~~n-~~memenna
.m.
..-n-.n~,,m~,nm
-.4.m.,4=o
.m.--m
. ~ ~. ~ ~ N. 7
- 1 *.,*. *. 9 9 7 9 a 9 " 1 * * * *. 9 a 7," 9 9 " * *. 9 9 "
- 9 * * * *. 999
- q*
a
.m.
.Nmm
~menm.mm-n--.~m mm
-~~--,~,--mm
,-~-~
u b
w 5
x I
~
U neunnum...mmemmen--anm
~.
m-mmeaee~e-m.-
n.---
~..eenu
~
m N--m N--~
~
-~-N
-u-~---u uu 3
w C.
m O
W
~
n
~
u em...nm.emm.m..eeee.~m-Nomn-ne.mm u-menenn.eeeee.n.nem gg,g4444444;;;;4444444444444444444444444444444444444444444
-- I I I'Og. I r-d-.5 B 5 a
5 ------------------------------------------------------
gwe
- wwww w wwww ww www ww ww ww w www w ww w w www w w ww w ww w w ww www ggwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwww g
-I MBEEEEEEEEE.EEEEMEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE 8
mw wwwww wwwww wwwwwwwwwwwww wwwwwwwwwwwwww wwwwwwwwwwwww a
s O
d-ed J
J dd d
e ed dde m
O O
0000000000000000000000000000000000000000000000000000 d
u uuuuutuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuxWuuuuuuu
@ - N N. m... d e. P. n - N,. n e - N M m e n n e e e p - N M,,
M # m a g n e M M n,P S. O - N m a
D me.
nnnnnn-NuNNNNuuuummmmme emme mm,<
gv
NNNNNNNNNNNNNNNNN NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN 8
S Y
memememmemmmmmememmmmmmmmmmmmememmmmmmmmmmmmmmmmmmmmem y
r.
Nc
SUP9 TART OF CT 1986 ED0Y CIAIPENT INSPECTION DAT3 9:21 WEDHESDAY. 19 ARCH 5 1986 13 LISTItG OF ALL TUBE FLAWS FCW STEArt SENER1 TOR C3 STEAft GENERATOR ROM COLLR94 LOC FLAN LOCATION FLAM HEIGHT (INCHESI FLAW SIZE t%I DEFECT VOLTAGE j
3 22 35 COLD TUBESHEET 1.8 48 1.43 1
3 22 36 COLD TUBESHEET 2.1 26 1.49 3
22 30 COLD TUBESHEET 2.5 18 3.11 3
22 37 COLD IUBESHEET 2.3 7
4.04 3
22 38 COLD Tt2ESHEET 2.6 16 4.34 3
22 39 COLD TUBESHEET 2.5 17 1.99 3
22 40 COLD TUBESHEET 2.3 29 8.94 3
22 43 COLD TUBESHEET 1.8 le 1.82 3
22 48 COLD TUBESHEET 1.4 15 6.88 3
22 49 COLD TUBESHEET 1.8 15 4.46 3
22 50 COLD Tt2ESHEET 1.7 25 2.29 3
22 51 COLD TUBESHEET 0.7 IS 3.99 3
22 53 COLD TUBESHEET 1.0
~
17 2.77 3
22 54 COLD TUBESHEET 9.8 5
2.67 3
22 55 COLD TUBESHEET 3.5 20 0.92 3
22 55 COLD TUDESHEET 2.5 14 1.98 3
22 57 HOT TUBESHEET I.1 27 0.61 3
22 59 COLD TLSESHEET 3.3 10 1.36 3
22 62 COLD TUBESHEET 1.7 3
1.08 3
22 66 COLD TUBESHEET 2.1 12 1.86 l
3 22 68 COLD TUBESHEET 2.3 12 1.94 l
3 22 69 COLD TUBESHEET 2.3 15 3.52 3
22 71 COLD TUBESHEET 2.7 2
2.74 3
22 72 COLD TUBESHEET 2.3 12 4.71 3
22 73 C0tB TUBESHEET 2.4 10 4.64 1
3 22 74 COLD TUBESHEET 2.2 6
3.75 3
22 75 COLD TLEESHEET 2.7 8
1.04 3
22 76 COLD TUBESHEET 2.5 9
2.16 3
23 21 COLD TL2ESHEET 1.1 12 2.33 3
23 22 COLD TUBESHEET 1.1 17 1.79 i
3 23 25 COLD TUBESHEET 2.1 22 2.72 3
23 25 COLD TUBESHEET 2.5 14 1.81 1
3 23 26 COLD T12ESHEET 2.8 35 0.78 i
3 23 27 COLD TUBESHEET 3.8 21 2.42 A
3 23 28 HOT TUBESHEET 1.8 23 1.03 3
23 28 COLD TUBESHEET 3.8 12 6.81 3
23 29 COLD TUBESHEET 2.8 11 6.64 i
3 23 30 HOT TUBESHEET 1.7 9
1.70 l
3 23 30 COLD TUBESHEET 2.9 19 6.72 3
23 31 COLD TUBESHEET 2.9 15 5.5G 3
23 32 COLD TUBESHEET 3.2 8
2.52 3
23 33 COLD Tt2ESHEET 2.6 23 1.02 l
3 23 34 COLD TUBE 3HEET 2.7 18 4.05 j
3 23 35 COLD TUBESHEEY 2.0 22 2.55
]
3 23 35 COLD TUBESHEET 2.8 12 2.29 3
23 36 COLD it2ESHEET 2.2 24 2.84 3
23 37 CotD TUBESHEET 2.2 22 1.65 3
23 37 COLD Tt2ESHEET 2.8 5
3.17 3
23 38 COLD TUBESHEET 2.7 12 3.94 3
23 39 COLD TUBESHEET 2.6 15 3.22 3
23 40 COLD TUEESHEET 4.4 2
1.25 3
23 44 COLD TUBESHEET 2.0 19 1.17 3
23 46 COLD TUBESHEET 2.2 5
1.34 l
3 23 47 COLD TUBESHEET 1.4 to 5.13
/
7 I
0 1
68 E
9 G
1 A
T L
5 O
431486291293446259389893888451862558785228599895237916 V
501 113628665164852338918872498332324841678031722125,661 H
C T
853231132112312323233321224212213416643122231234111224 R
C A
E 9
F 3
E D
Y A
O S
EH l
D X
E I
W E
1 Z
2 I
508339538254376S6682ee5533944666655157e76S122906824424 S
12222121 2
1 1 I 1
ll1111 1111 1 211 l
2I121211 21122 0
N AL F
A T
5 A
5 S
EH N
C O
N I
I T
I C
697222483192255344046697539728081798090838871774482978 E
T PS H
3!3132181321311122222222221e3I232233323323223222222111 SW3 G
NA8 I
IL E
FR H
T O
NtT N
EeA A
EiR L
STE F
LCLE LS fA 0
M 0FA EOE N
T O
TTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTT 6GS I
EEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE 6t T
EEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE 9IR A
HHHHHHHHHHHHHHHHHHHHHHHHHHHEHHHHHHHHHHHHHHHHHHHHHHHHHH 1TO C
SSSS5S5S$SS5S5S555SSSSSSS5SSSS5555S5555SSSSSSSSSSSSSSS 2F O
EEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE f1 L
SBBEeEB2BBSBBBEBeSSS2SBBAemBBSBBBBe22B2SEeEBEESSEBEEEB CL L L UUt L UL UUL t ULL UL L LL 1 L t t t i UUL t UUUt t t Ut LUt t UtUL L L UUt t U N
TTTT7TTTTTT7TTTTTTTTTT77T' YTTTTTTTT7T7T7TTTTT7TTTTTTTTT F
A O
L F
ree te P
3SOSDDODDSSDDSSSDSDSSBOOBDDDDDSDBOOSSODSSaO0DDBDSDOoOD U
C 1 LLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLtLLL' LLt LtL1 i i tLLLLtLL S
O 0OOOOOOOOOOOOOOOOOOOOOOOOOOOOOOO0OOODOOoOoO0oo0OOOOoOO L
0CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCtCCCCCCCCCCCC 499 890122344567841267899123456124556789012233455678233456 L
L 445555555555566666667777777222222222333333333333444444 O
C W0 333333333333333333333333333444444444444444444444444444 9
222222222222222222222222222222222222222222222222222222 M
TAW EN E
333333333333333333333333333333333333333333333333333333 G
M A
S b
e o
N 5
y r s
.-__4,.*..--Nm..
n..,__m,m.,.~..mmN-m..a_._...__.mmeNN.e $nnen_-N<es-e
_~, _s _ N _. _s - N e - m e n. n. - n. _.
8 Nm__.2_n,ns n
mN_
N m u. m N ed N N N N m m.
_NNNmNm
-N-N.mu
- _N_m, r
a N
I N
.N N N _ N _d __.. N #. 4 d. _... m W N W. e d e k N _d M N @.._. _.. m 4 k m e te m d.. m_.... _N d N
Mn NN___
N__
m_
__N N
N 3ww 4
M D
w M
M
~
u
<<_m.No.<m_e. Nan.
<<N.
mnamemnm_n.
n.ma.<--r._mNem.m.e gg,g444444444444444444444444444444444444444444444444444444
_2-
- 8 I
- 5 fm w
r-d-W
- 8:E E ------ ---------------
ww-w------
8
---m----------------
e_ n - wwwwwww wwwwwwwwwwwwww ww www wwwwwwwwwwww www g E555555555555555555555Ewwwwwwww554555555wwwwwww5ww www wwwww wwwww wwwwwwwww wwp wwww www "8
55555555 5555555 555555 gw Ewwgg8828ggwwwggwwwww www gwww gw
- 282-NERE588 I$$2 28-_-u e--
M ae B---ggggggggwggwggwpIwggg ND 5
w*
e.e
.......s...eO...e.ees....e....O....
2...... 8.
1 -
...._Nm....~.N..
-...N_NNm..
~NW.-......_Nm..
4
((femMmmmedded@@@deWWNN-N-bb
-b N N N ed N N N N N e m m m m M M e
b
$$$$$$$$$$$$h$$$$$$$$$$kO$$$$$$$$$mbbhhhhhhh hmm$hhmhh N N N N N N N N N N N ed N ed ed N ed N tw N ed N N N N td (d N ed N N ed N to N N N ed ed ed N N to N 06# Gd ed ed ed et N te N tw 8
I g mmmmmeenemenemmmmmmmmmmmmmmmmemmmmmmmmmmmmmmmmmmmmmmmm 5
e e
N I
i;;sasa;;;;;;;;;;;;<;;;;;;;;;;;;;;;;;;a.---~~m.,---~~--e 3
n
-~.-~m
~~~-~-~~..m..-~~~~~m--m..mm~~-~,na;;;";;;;;;;;;;
g a
X Sw 5
N I
h*22**R2'0***u2**** tat""uf.*:tt*=*2:*2*A*25:2+:*g*at2*
~
m O
E W
=
~
g~
.qqm3 3e,e,,5.qme.
~ ~ ~ ~ - - - ~ - -.. - - - - - m te g = g. g e,3 ~.g q q q q. m q. - q q. e,, e q,q
< 5 3. q u
gm,
- -. ~ ~ ~.. m ~ m ~ - ~ - ~ -. - - ~ ~, m.d e - m e m - m
-~
I W
.E.
U* -
r d-.5 S 5 8*
5 - - ~ ~ - - - - - - - - - - - - ~ ~ - - - -. - -.. - - - - - - - - - -.- -
.--~~----
"* O j58 E 5 E 5 5 5 E " "'. " "E R I d : : " " : E " d U "E 5 5."I " t " $ "ERh555T5,272E""- 5.5#
- 0"d"I M 5"
- 50. "
2005:0050 5E555AEE E55
&E E
- m.
~~-- ------- ------ ---- ----
g II I E N E -- I u E*- $-.E# E--u-- $~--w--
..--- E ----- IE-I a*
5l
! s*e*ssa*u*aSSSSSSS*SS d!eceeesc5ddeoesedoressesseesse5c,es*aBSSSSaSa*aSgsaSag S S S e
seeeeeesseer i
vesss:ssssau:4:::::":::::::: cucteneen :.tece==anx====
5 g...............................................Ntoedtdfd e d N se ed ed ed N ed ed ed ed ed N to ed - ed fd PJ N ed N N ed ed eJ N #A N GJ to ed #4 ed ed to ed e d DJ ed ed ed N ed to ed ed Ed.
8
%a emmmmememmmmmmmmmmmmmmemmmmemmmmmmmmmmmmmmmmmeneemmmmm g
ITe
t N
N i
I e es:::::::::::::::: :::::::::::: xs:::ssness:::::e::sm:
l 5
- 4444d444444dd4444d444444dd444444444d4dd444d4444444d4d4 g
A E
m
~~ ::: s-s =::=<c-::= :<~~s~
s-stat==-s~--ess-~=-====
~
4
.a I
l m.
i a
~
i c
m-.-,N-e.---,mN._,
--....-,-m.m.N---.--N..NN.-..N
,N..
45444444d544d44d44444444444444444444444444444455554444
~lu-s r 1
=~n s
- g..
v-
=3
-n va= s ----------------------------------------
3 9 = =
- - N.=a =a.=m.m= =a =.=.= =a.R..X..N s - R.a.K mam. m a aK a m a m..s..N. K.a.m. aam ma a a a 8
m-Ese N n2 228882s0s50 58828M88s8sesMsUB0ss Rs05sssMs8ss c
a l
g3!sessesseeasessessee!a888888880essessee-seessees=eesee a
eessesses seessees eessee a8888888e!s88888888 s
sesse l
3:377 $$$ 735: 2 2:$ 3:2:3.2.2333 ::# 42:2F ::=24:*
NNb O N ew t t e e t
t t
t N N
0 t NNNN NNNNNNN E'
.rg enemmenemmmmmennmemmemmmmmmmmennmemmmenemmmmmmmmmmmemm l
5 n
a b
i l
l
t
=
1 g
f 802.;99~~1ss.;;;89998;n499*s.qqquqqqqqqcqsqqqqmqqqqqqqqqq g
n N..--NMMN_
N-M-M.NM__.~.-NMNNMN_MNNNMN__N___
NMMMM-M_M a
ex a=
n v
M a ce=
=- sen::
====M::ces+sse=es++e-s~~ ames~:-es==,ne
~
a e
S i
i
=
..-NMM.N._
._.-.....MN..--....-.......N N.NN....NNNM
((,.ydddddddddddddddddddddddddddddddddddddddddddddddddddd,d d
-r E-s a 8Ee;e u
-<ss g ~! E ! : X N a.E : E E E B E : X.a a N a N I.N m R a a
- E NassaaN.EE:E:::E:EEEE:55:E:55:E:555E9:: ::555 s8 X M.
cm R s88 28s2se 8288s8ses5888s82s8s842ssEssa85sss25s8 e
B 5558558e085588588885858e8.855e8eesessaeesseseeevesessesse d
de J-
-e a
a l::ssess:::::nm===ss:::::::::::::::ennuu=4u:=x==xx:
I - - - - - - - - - - - N N N N N N N N N N N N N N N N N N N N N N id W N N N N ed N N N N N ed N NNNNNNNNNNN a
MMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM 1-M
f N
.I I
d l 2: 2 2 2:*:2 3 3 R2 2. f*
00:2:**A* 3A "3: 332 345 Ki:2 3 307: 4
- 4444444444444444JJ44444444444JJJ4444444444444444444444 u
E Rw a
u 5
j 5 21 * *:C*021:22"0 022*%*A222%C:fon:2"Sn%*
- 20*21"tC002 3a-2 e
y
,E.
2, C
...m.-
..--.M.,
.......N.M.-.........
...<,m-~..<,,N..
9.,<j 44444444444444444JJJJ444444444444444444444444444444444 2 9.
>d
""E W
V.
~Bu 5 y
d3 E'E
- 8 gg E ~~.-.-..-..--~~~~~~g--.-
g- --g-.-.---- e-~~g------
g-- g-e--
M
- K = X X. X X. X =a E X m a.N a R m. X a..X X.E s a.N.a.m a N K a.X.m a s a m gg g g.
.g g.
gge g g gg
.05 8
4 Sg.
B BB BB $$$
$ BB B B B
o y
8 a
l
$ 5"SDSS* SASS"**SSS"SSSaS**SS*S aS "S*"SaSaSaSSS=SSSSS=SS 888858588585888588888588888E8825888858888888888888888 8
RKRA7770015710723$2 3~2 0:332 233 3:334 :::::::: 2440R 8
8
...........m..........................................
N ed N N N N to to N ed ed te ed 94 (d N N N 84 N N N to N N Gd td ed 9e ed N N N #d to N ed N N 84 N ed f4 N f.) N ed ed N ed N N N N I
B.
MMmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmm,mmmmmmmmm 5
l I
7...
e F
O m
N W
G-m e
O m
O
..m....m.m.
~Nm#es..u...mmemN#mm
..m,NNm m
whmN.No.mes G. H. N. #. e. h. m. >. N. 4. h. e. M. N. m. e. m. O. @. 4 4 0 4 4. N. M. 4. N. n. 4. m. p 4. G. M. 4. m. k. e. h. m. e. m. m. m. M. M. e. m. @. o M N d S N m N N M f M M f M m M N u m N m N m H N a m N N N N m M m N N N m M m m m 4 N N M M M M U
- m. 4. m.
k Nmm k
u 4
W E
hw O
4 8
O
.x B
N..
.MNm0SbedGWDePNhM4MNMmMM@NMMee@fmmNNOMmMNOM@NOONW>OOO45 mm m-mNummmNNm m-Nmm m
mM memNumNNuNmNmmNmm mNmm a
S O-m ti e
O W
b a
m 3
~
... a. n. n. N. m.
- e. <. N. m. e. e. r. n.
m.
.... e. r. e. m. a. m. e. a. <. <. m. e. e. e. m. 4. N. m. n. e. m. N. o.. a.. < N.
I.
Mg meeGamWNNNNmNmNmW4NmNMNMNMNmMNmHNammmeONmNmmNNNNNNNNNN Mw W
- 8
-Zw-2 gE 3
W -
d5
-a "85 8
E w---
www-w~~--
w-w------
w-------m
- ge m
w
.w
.ww m.
. www....
--w-www--w mmmw--
ww.wmm c_
5. g w w-w w w w w w w. w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w. w w w wg
- 8
<555555555555555555555555555555555555555555555555555 8
om
--www mw ww.
wwww w
.w mmwwwm ww mw wwww.ww.m D:
E E 38 8 E B E B B E E.B B B B E B B E E B B E E B E E B B E' B E 8 88 8 8 8 8 E B B B B B S B E 8 4ms-
c-B 3'
l S-SSSSSS"a*SSSS*S*S"aSSSaSSSSSaSSSSa**SaS*SSSSaa**S*S COWC0000C00000000000000000000000000000000000000000B000 uz uuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuvuvuvuuu w
de@hhe@OmNmM4dedhhWW&@@OmmNmm4mmehe>Ow m
NNMMdemhPOwNembe w
NWGNNNNmMMMMmMMemMMmMMf 4444444444444 mmmmmmmmm4444@d4 Ou eme@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@
m NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN 8
I. mmmmmmmmMmMmemmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmMemmm G
5 ne
SLRMARY OF CY 1986 EDDY CURRENT INSPECTIDH CATA 0:21 WEDHESDAY. t1 ARCH 5, 1986 25 e
LISTItG OF ALL TUBE FLAWS FOR STEAtt GENERATOR 83 STEAtt GENERATOR ROW CCLUrte LOC FLAW LCCATI0t1 FLAW HEIGHT IINCHESI FLAW SIZE (XI DEFECT VOLTAGE 3
29 70 COLD TUBESHEET 1.1 4
1.48 3
29 71 COLD TUBESHEET 1.1 20 1.12 3
29 71 COLD TUBESHEET 1.6 8
0.99 3
29 72 COLD TUBESHEET 1.8 15 0.92 3
29 82 HOT 210 AVS 0.0 6
3.08 3
29 82 HOT 4TH AVB 0.0 6
2.93 3
29 87 HOT IST AVB 0.0 2
3.66 3
29 89 HOT IST AVB 0.0 1
5.10 3
29 90 HOT IST AVB 0.0 1
,3.50 3
30 29 COLD TUBESHEET 1.6 25 1.75 3
30 30
' COLD TUBESHEET 2.2 13 1.57 3
30 31 COLD TUBESHEET 2.2 28 2.61 e
3 30 32 00LD TUBESMLET 2.7 11 3.56 3
30 33 COLD -
TUBESHEET 3.2 18 1.52 I
3 30 34 COLO TUBE 3HEET
~ ~ 2.6 i
21.-
4.03 3
30 35 COLD ILOCSHEET 2.6 12 4.95 3
30 36 COLD TU6ESHEET 2.8 4
3.47 3
30 37 COLD TUBESHEET 3.2 28 1.11 3
30 37 COLD TUBESHEET 4.4 9
0.82 3
30 38 HOT TUBESHEET 3.9 18 1.40 3
30 38 COLD TUBESHEET 2.7 17 1.60 3
30 39 COLD TUBESHEET 3.8 16 0.52 3
30 40 COLD TUBESHEET 2.6 18 1.97 3
30 40 COLD TUBESHEET 3.5 14 1.70 3
36-41 COLD TUBESHEET 2.5 16 1.27 3
30 41 COLD TUBESHEET 3.2 7
2.09 3
30 42 COLD TLPIESHEET 2.5 21 2.34 3
30 43 COLD TU2ESHEET 2.2 17 1.77 3
30 44 COLD TUBESHEET 1.7 29 2.73 3
30 44 COLD' YUCESHEET 2.9 21 1.51 3
30 45
' COLD TL'BESHFET 2.1 27 1.40 3
30 45 COLD TUBESHEET 3.2 11 1.83 3
30 46 COLD TUBESHEET 1.3 39 0.90 3
30 46 COLD TLEESHEF T 2.4 14 1,32 3
30 47 COLD TUBESHEET 1.5 70 2.01 3
30 48 COLO TUBESHEET 1.2 11 3.90 i
3 30 49 COLD TUBESHEET 1.2 19 2.33 i
3 30 52 COLD TUBESHEET 1.1 36 -
0.52 l
3 30 52 COLD TUBESHEET 1.7 13 0.98 3
30 53 COLD TUDESHEET 0.8 28 2.64 3
30 53 COLD TUBESHEET 1.9 9
1.34 3
30 54 COLD TUBESHEET 1.1 8
3.08 3
30 54 COLD TUBESHEET 2.6 4
2.44 3
30 55 COLD TUBESHEET 1.3 9
3.71 l
3 30 55 COLD TUBESHEET 1.6 35 0.65 3
30 55 COLD TUBESHEET 2.9 7
1.43 3
30 56 COLD TUBESHEET 1.7 12 2.50 3
30 57 COLD TJBESHEET 1.8 14 1.57 3
30 57 COLD TUBESHEET 3.0 2
1.45 3
30 59 COLD TUBESHEET 2.1 8
1.62 3
30 60 COLD TUBESHEET 3.0 14 2.91 3
30 61 COLD TUBESHEET 3.0 20 1.23 3
30 62 COLD TUBESHEET 2.7 9
2.20 3
30 63 COLD TUBESHEET 2.9 16 2.67
{
i
SLRS1ARY OF CY 1986 EDOY CURRENT INSPECTION DATA 0:21 WEDHESDAY. MAPCH 5. 1986 27 LISTIts OF ALL TUBE FLAWS FOR STEAN GENEIATOR 83 STEAN GENERATOR ROW COLLR94 LOC FLAW LOCATION FLAW HEIGHT IIHCHES)
FLAW SIZE (XI DEFECT VOLTAGE 3-30 64 COLD TUBESHEET 2.8 22 1.06 3
30 65 COLD TUBESHEET 2.5 2
1.9S 3
30 66 COLD TUBESHEET 1.5 22 1.07 3
30 66 COLD TUBESHEET 3.1 14 1.01 3
30 67 COLD TUBESHEET 2.7 18 3.72 3
30 68 COLD TUBESHEET 1.7 7
3.55 3
30 70 COLD TUBESHEET 1.3 8
1.70 3
30 71 COLD TUBESHEET 1.7 12 2.46 3
30 72 COLD TUBESHEET 1.1 9
1.59 3
30 87 HOT IST AVS 0.0 14 6.60 3
30 69 HOT IST AVB 0.0 1
9.25 3
31 27 HOT TUBESHEET 3.4 4
3.28 3
31 27 COLD TUBESHEET 3.8 7
1.56 3
31 28 COLD TUBESHEET 0.8 12 1.64 3
31 29 COLD TUDESHEET 1.5 32 0.65 3
31 29 COLD TUBESHEET 7.8 8
0.77 3
31 30 COLD TUBESHEET 2.2 10 1.34 3
31 31 COLD TUBESHEET 1.7 46 1.29 3
31 32 COLD TUBESHEET 2.2 28 3.38 3
31 33 COLD TUBESHEET 2.6 13 4.40 3
31 34 COLD TUBESHEET 2.6 24 2.93 3
31 35 COLD TUBESHEET 2.7 47 0.71 l
3 31 35 COLD TUBESHEET 3.7 12 1.76 3
31 36 COLD TUBESHEET 3.0 24 1.11 3
31 37 COLD TUBESHEET 2.6 23 1.61 3
31 37 COLD TUBESHEET 3.3 22 5.36 3
31 38 COLD TUBESHEET 2.5 37 1.43 3
31 38 COLD TUBESHEET 3.6 15 3.04 3
31 39 COLD TUBESHEET 2.5 43 0.26 3
31 39 COLD TUBESHEET 3.2 22.
1.24 3
31 40 COLD TUBESHEET 3.2 21 1.09 3
31 41 COLD TUBESHEET 3.1 18 2.42 3
31 42 COLD TUBESHEET 2.6 27 1.20 3
31 43 COLD TUBESHEET 2.6 39 0.55 3
31 44 COLD TUBESHEET 2.6 33 1.48 3
31 45 COLD TUBESHEET 1.4 39 1.54 3
31 45 COLD TUBESHEET 3.2 10 2.51 3
31 46 HOT TUBESHEET 2.8 8
1.88 3
31 46 COLD TUBESHEET 1.6 19 1.62 3
31 47 COLD TUBESHEET 1.7 22 2.16 3
31 48 COLD TUBESHEET 1.3 16 2.60 3
31 48 COLD TUBESHEET 2.3 10 1.41 3
31 49 COLD TUBESHEET 1.7 17 2.29 3
31 50 COLD TUCESHEET 1.6 15 2.05 3
31 51 COLD TUBESHEET 2.8 14 0.73 3
31 52 COLD TUBESHEET 0.8 48 0.93 3
31 52 COLD TUBESHEET 2.5 12 1.19 3
31 53 HOT TUBESHEET 5.0 7
1.44 l
3 31 53 HOT TUBESHEET 5.2 6
0.20 3
31 53 COLD TUDESHEET 1.9 28 1.10 3
31 53 COLD TUDESHEET 3.7 5
1.75 3
31 54 COLD TUBESHEET 2.9 28 0.95 l
3 31 55 HOT TUBESHEET 3.7 29 0.53 3
'31 55 COLD TUBESHEET 1.5 28 1.46 l
=
Sutt'.ARY OF CY 1986 EDOY CURRENT INSPECTION DATA 0:21 WEDNESDAY. MARCH 5, 1986 28 LISTIt'3 0F ALL TUBE FLAWS FOR STEArt [ENEIATOR 83 STEAM GENERATOR ROW COLUt94 LOC FLAW LOCATION FLAW HEIGHT IIHCHES)
FLAW SIZE 1%)
DEFECT VOLTAGE 3
31 55 COLD TUBESHEEE 2.9 13 2.23 3
31 56 COLD TUBESHEET 3.2 6
3.73 3
31 57 COLD TUBESHEET 2.2 14 1.52 3
31 57 COLD TUBESHEET 3.3 9
3.14 3
31 58 COLD TUBESHEET 3.1 12 1.91 3
31 59 COLD TUBESHEET 2.9 21 3.73 3
31 60 COLD TUBESHEET 2.9 17 1.08 3
31 61 COLD TUBESHEET 2.3 13 3.56 3
31 62 COLD TUBESHEET 2.1 14 4.28 3
31 62 COLD TUBESHEET 3.1 12 1.89 3
31 63 COLD TUBESHEET 1.8 19 1.39 3
31 64 HOT TUBESHEET 1.0 10 2.22 3
31 65 COLD TUBESHEET 1.7 9
2.14 3
31 65 COLD TUBESHEET 2.9 5
2.75 3
31 66 COLD TUBESHEET 1.5 10 2.47 3
31 66 COLD TUBESHEET 2.4 7
1.97 3
31 67 COLD TUBESHEET 1.4 27 1.33 3
31 67 COLD TUBESHEET 2.2 17 1.73 3
31 68 COLD TUBESHEET 1.3 16 2.82 3
31 68 COLD TUBESHEET 2.2 18 2.78 3
31 69 COLD TUBESHEET 1.2 24 1.95 3
31 69 COLD TUBESHEET 2.2 17 1.29 3
31 70 HOT TUBESHEET 1.6 28 0.84 3
31 70 COLD TUBESHEET 1.7 30 0.97 3
31 70 COLD TUBESHEET 3.6 3
2.62
)
3' 31 71 COLD TUBESHEET 0.9 40 0.77 3
31 71 COLD TUBESHEET 1.2 10 3.52 3
31 73 HOT TUBESHEET 2.3 6
2.01
,3 31 76 HOT 4TH AVB 0.0 19 1.27 3
31 78 HOT IST AVB 0.0 4
3.71 3
31 80 HOT IST AVB 0.0 10 1.94 3
31 84 HOT IST AVB 0.0 40 3.71 3
31 85 HOT IST AVB 0.0 1
1.51 3
31 86 HOT IST AVB 0.0 19 4.51 3
32 29 COLD TUBESHEET 0.9 38 0.56 3
32 29 COLD TUBESHEET 7.2 12 0.73 l
3 32 30 COLD TUBESHEET 1.2 52 0.28 l
3 32 30 COLD TUBESHEET 1.8 17 0.56 3
32 31 HOT TUBESHEET 2.7 32 1.00 l
3 32 31 COLD TUBESHEET 1.1 59 0.51 3
32 31 COLD TUBESHEET 3.3 36 0.97 3
32 32 COLD TUBESHEET 1.6 23 J.60 3
32 33 COLD TUBESHEET 1.9 43 1.50
(
3 32 33 COLD TUBESHEET 2.3 12 1.71 l
3 32 34 COLD TUBESHEET 2.3 38 0.75 l
3 32 35 COLD TUBESHEET 2.3 27 1.28 l
3 32 35 COLD TUBESHEET 3.6 20 1.44 3
32 36 COLD TUBESHEET 2.2 31 1.65 3
32 36 COLD TUBESHEET 3.6 13 0.75 3
32 38 COLD TUBESHEET 2.1 20 0.98 3
32 38 COLD TUBESHEET 2.8 9
1.35 3
32 39 COLD TUBESHEET 2.1 16 0.96 3
32 41 COLD TUBESHEET 1.9 22 0.82 3
32 42 COLD TUBESHEET 1.7 17 1.03
Sutt1 arf DF CY 1986 EDDT CURRENT INSPECTION DATA 0:21 NE0tIESDAY, ItARCH 5. 1986 20 LISTIt~a CF ALL TUBE FLAWS FOR STEAM CENEIATOR 83 STEAM GENERATOR R0W COLUNH LOC FLAW LOCATION FLAW HEIGHT (INCHESI FLAW SIZE 8%)
DEFECT VOLTAGE 3
32 43 COLD TUDESHEET 1.4 29 2.00 3
32 43 COLD TUDESHEET 2.0 17 2.28 3
32 44 HOT TutsESHEE T 1.7 10 1.44 3
32 44 COLD TUBESHEET 1.4 19 2.54 3
32 45 COLD TUBESHEET 2.9 6
2.15 3
32 46 HOT 2HD AVB 0.0 4
1.61 l
3 32 47 HOT TUBESHEET 1.4 14 2.03 3
32 47 COLD TUBESHEET
!.6 17 2.13 3
32 49 COLD TUBESHEET 1.3 10 2.34 3
32 51 COLD TUBESHEET 1.0 28 1.88 3
32 53 COLD TUBESHEET 1.2 15 0.97 3
32 53 COLD TUBESHEET 3.4 7
1.00 3
32 54 HOT TUBESHEET 1.5 9-1.08 3
32 54 COLD TUBESHEET 1.5 33 0.62 3
32 55 COLD TUBESHEET 3.1 13 1.18 3
32 56 COLD TUBESHEET 9.9 17 3.21 3
32 57 COLD TUBESHEFT 2.2 17 4.44 3
32 57 COLD TUBESHEET 3.3 16 4.53 3
32 58 HOT TUBESHEET 2.1 7
0.82 3
32 58 COLD TUBESHEET 2.1 26 2.73 3
32 58 COLD TUBESHEET 3.1 18 2.21 3
32 59 COLD TUEESHEET 3.2 22 1.40 3
32 60 HOT TUEESHEET 2.7 6
1.62 3
32 60 COLD TUBESHEET 1.9 28 1.65 3
32 60 COLD TUBESHEET 3.1 12 2.00 3
32 61 COLD TUBESHEET 3.7 25 2.70 3
32 61 COLD TUBESHEET 3.0 13 3.13 3
32 62 COLD TUBESHEET 1.6 18 1.65 3
32 63 COLD TUBESHEET 3.2 6
1.33 3
32 64 COLD TUBESHEET 2.9 13 3.61 3
32 65 COLD TUBESHEET 2.9 4
2.82 3
32 66 HOT 4TH AVB 0.0 5
2.03 3
32 66 COLD TUBESHEET 1.6 37 0.73 3
32 66 COLD TUBESHEET 2.9 6
1.87 3
32 67 HOT TUBESHEET 1.7 6
1.05 3
32 67 COLD TUBESHEET 0.8 44 1.48 3
32 68 COLD TUBESHEET 1.6 10 3.14 3
32 69 COLD TUBESHEET 1.6 26 0.98 3
32 70 COLD TUBESHEET 0.8 22 4.12 3
32 71 COLD TUBESHEET 0.9 14 1.44 3
32
~ 80 HOT IST AVB 0.0 22 3.93 3
32 80 HOT END AVB 0.0 7
4.27 3
32 83 HOT IST AVB 0.0 23 2.71 3
32 86 HOT IST AVB 0.0 1
5.01 3
32 86 HOT 4TH AVB 0.0 1
2.63 3
32 86 COLO IST TSP 25.5 10 2.66 3
32 87 HOT IST AVB 0.0 6
5.40 3
32 88 HOT IST AVB 0.0 66 1.25 3
33 29 COLD TUBESHEET 1,0 18 0.61 3
33 30 COLD TUBESHEET 0.4 23 3.03 3
33 30 COLD TUBESHEET 3.3 7
1.03 3
33 31 COLD TUeESHEET 0.7 51 0.83 3
33 31 COLD TUBESHEET 2.5 69 0.52 3
33 32 COLD TUDESHEET 1.4 30 1.02
Sutt1ARY OF CT 1986 EDOT CURRENT INSPECTION DATA 0:21 WEDNESDAYe t1 ARCH 5. 1986 30 e
LISTING OF ALL TUBE FLAniS FOR STEAtt GENE::ATOR 83 STEAPI GENERATOR POW COLUNN LOC FLAW LOCATION FLAW HEIGHT IINCHESI FLAW SIZE 1%)
DEFECT VOLTAGE 3
33 33 COLD TUBESHEET 1.6 26 1.34 3
33 34 COLD TUBESHEET 1.8 26 1.56 3
33 36 COLD TUBESHEET 2.3 28 0.39 3
33 36 COLD TUBESHEET 3.5 24 0.79 3
33 37 COLD' TUBESHEET 2.7 25 3.11 3
33 37 COLD TUBESHEET 3.5 6
1.90 3
33 38 HOT TUBESHEET 1.7 18 0.85 3
33 38 HOT IST AVB 0.0 5
5.38 3
33 38 POT 2tc AV8 0.0 19 2.04 3
33 38 COLD TUBESHEET 2.2 25 2.56 3
33 38 COLD TUBESHEET 3.5 10 1.66 3
33 39 COLD TUBESHEET 2.1 3
1.39 3
33 40 HOT TUBESHEET 2.2 28 0.94 3
33 40 COLD TUBESHEET 2.1 10 0.75 3
33 41 COLD TUBESHEET 3.8 11 1.79 3
33 42 HOT TUBESHEET 2.4 9
2.03 3
33 42 COLD TUBESHEET 3.7 24 1.68 3
33 43 HOT TUBESHEET 1.6 f4 0.36 3
33 43 COLD TUBESHEET 1.4 36 1.28 3
33 44 HOT IST AV8 0.0 2
2.80 3
33 44 COLD TUBESHEET 1.4 25 1.13 3
33 44 COLD TUBESHEET 2.7 6
1.84 3
33 45 COLD TUBESHEET 2.4 35 0.53 3
33 45 COLD TUBESHEET 2.7 12 0.72 3
33 46 HOT TUBESHEET 1.7 17 1.29 3
33 46 HOT 2tK) AVB 0.0 9
3.17 3
33 46 HOT 3RD AVB 0.0 3
5.62 3
33 46 COLD TUBESHEET 1.2 29 1.12 3
33 47 HOT TUBESHEET 1.0 42 1.09 3
33 47 COLD TtJP' HEET 1.6 28 2.97 3
33 48 HOT T h IEET 2.2 17 2.15 3
33 48 HOT IST AVB 0.0 1
7.19 3
33 48 COLD TUBESHEET 1.2 22 3.48 3
33 49 COLD TUBESHEET 1.2 37 1.86 3
33 51 COLD TUBESHEET 0.8 19 2.30 3
33 51 COLD TUBESHEET 1.0 26 1.28 3
33 52 COLD TUDESHEET 1.2 15 1.36 3
33 53 HOT 3RD AVB 0.0 7
0.66 3
33 53 HOT 4TH AVB 0.0 29 1.32 3
33 53 COLD TUBESHEET 1.1 33 1.60 3
33 53 COLD TUBESHEET 3.7 33 0.83 3
33 54 HOT 1UCESHEET 1.2 24 1.37 3
33 54 HOT TUBESHEET 1.8 17 1.17 3
33 54 COLD TUBESHEET 2.4 28 0.62 3
33 54 COLD TUBESHEET 3.2 12 2.26 3
33 55 HOT 3RD AVB 0.0 1
6.17 3
33 55 COLD TUBESHEET 1.6 27 1.54 3
33 55 COLD TUBESHEET 3.4 2
1.45 3
33 57 COLD TUDESHEET 2.7 29 0.53 3
33 57 COLD TUBESHEET 3.2 13 3.99 3
33 58 COLD TUBESHEET 1.6 29 2.79 3
33 58 COLO TUBESHEET 3.4 17 2.59 3
33 59 HOT 3PD AVB 0.0 1
4.31 3
33 59 COLD TUBESHEET 1.8 26 4.19 I
1
Sutt1A"Y OF CY IE86 ED0Y CURRENT INSFECTIDH DATA 0:21 WEDHESD AY, 71 ARCH 5,1986 31 a
LISTIta OF ALL TUBE FLAWS TOR STEAN GENERATOR 83 STEArt GENERATOR R0W COLLAN s LOC FLAW LOCATION FLAW HEIGHT IIHCHESI FLAN SIZE 1%I DEFECT VOLTAGE 3
33 59 COLD TUBESHEET 3.0 16 1.78 3
33 60 HOT TUBESHEET 2.8 17 0.86 3
33 60 HOT 4TH AVB 0.0 5
4.58 3
33 60 COLD TUBESHEET 2.3 33 0.49 3
33 60 COLD TUBESHEET 3.0 17 2.33 3
33 61 COLD TUBESHEET 2.1 32 2.57 3
33 61 COLD TUBESHEET 2.8 13 3.27 3
33 62 COLD TUBESHEET 2.0 28 1,54 3
33 62 COLD TUBESHEET 2.6 25 2.27 3
33 63 COLD TUBESHEET 2.6 17 3.72 3
33 64 COLD TUBESHEET 2.4 19 4.34 3
33 65 COLD TUBESHEET 1.3 31 2.39 3
33 65 COLD TUBESHEET 2.6 9
2.57 3
33 66 COLD TUBESHEET 1.6 26 2.34 3
33 67 COLD TUBESHEET 0.6 93 1.26 3
33 68 COLD TUBESHEET O.7 20 2.53 3
33 69 COLD TUBESHEET 0.7 22 3.49 3
33 71 HOT 2tE) AVB 0.0 5.13 3
33 71 HOT 3RD AVB 0.0 3
5.48 3
33 72 HOT TUBESHEET 2.5 3
3.20 3
33 73 HOT 4TH A%15 0.0 17 2.71 3
33 76 HOT 3RD AVB 0.0 43 4.56 3
33 76 HOT 4TH AVB 0.0 44 2.!!
3 33 83 UCT 4TH AVB 0.0 17 1.64 3
33 85 HOT IST AVB 0.0 1
4.76 3
33 86 HOT IST AVB 0.0 8
2.37 3
33 86 HOT 4TH AVB 0.0 4
3.32 3
34 29 HOT 2tE) TSP 12.2 8
1.19 3
34 30 COLD TUBESHEET 5.4 13 2.21 3
34 31 COLD TUBESHEET 0.9 21 0.88 3
34 32 HOT TUBESHEET 2.7 3
2.34 3
34 32 COLD TUBESHEET 5.4 13 1.82 3
34 33 COLD TUBESHEET 1.1 13 1.65 3
34 35 COLD TUBESHEET 1.8 30 1.29 3
34 36 COLD TUBESHEET 2.4 43 0.45 3
34 37 COLD TUBESHEET 1.8 34 3.82 3
34 37 COLD TUBESHEET 2.4 30 0.98 3
34 38 COLD TUBESHEET 1.7 25 2.54 3
34 39 HOT TUBESHEET 2.5 3
1.54 3
34 39 COLD TUDESHEET 1.9 2
1.35 3
34 40 COLD-TUBESHEET 2.4 28 0.63 3
34 40 COLD TUBESHEET 3.4 13 1.04 3
34 42 COLD TUBESHEET 0.9 20 1.10 3
34 43 COLD TUBESHEET 2.4 17 I.35 3
34 44 COLD TUCESHEET 1.4 29 1.52 3
34 45 COLD TUBESHEET 0.8 32 0.72 3
34 45 COLD TUBESHEET 2.1 5
1.19 3
34 46 HOT TUBESHEET 1.3 15 2.26 3
34 46 COLD TUBESHEET 3.1 25 1.14 3
34 47 HOT TUBESHEET 1.1 29 1.40 3
34 47 COLD TUBESHEET 1.8 25 2.62 3
34 48 HOT TUDESHEET 1.4 24 2.31 3
34 48 HOT 2HO AVB 0.0 10 2.70 3
34 48 COLD TUBESHEET 1.3 25 3.67
SutttARY OF CY 1986 EDDT CURRENT INSPECTION CATA 0:21 WE0t3ESDAY, MARCH 5. 1986 32 e
LISTIlfG OF ALL TUBE FLAWS FOR STEAN GD4ERATOR 83 STEAM GENERATOR ROW COLUt94 LOC FLAW LOCATIDH FLAW HEIGHT IIHCHES)
FLAW SIZE (7.1 DEFECT VOLTAGE l
3 34 49 HOT 2ND AVB 0.0 12 8.72 l
3 34 49 HOT 3RD AVB 0.0 6
8.14 i
3 34 50 COLD TUBESHEET 0.1 25 2.13
(
3 34 51 COLD TUBESHEET-0.7 29 1.58-3 34 51 COLD TUBESHEET 2.2 8
2.27 3
34 52 COLD TUBESHEET 0.8 28 1.62 3
34 52 COLD TUBESHEET 2.4 7
1.72 i
3 34 53 COLD TUBESHEET 1.3 27 1.70 l
3 34 53 COLD TUBESHEET 2.9 20 0.84 3
34 54 HOT TUBESHEET 1.9 14 0.71 3
34 54 HOT 3RD AVB 0.0 4
4.31 3
34 34 COLD TUBESHEET
!.5 17 1.75 3
34 54 COLD TUBESHEET 3.0 14 2.95 3-34 55 COLD TUBESHEET 1.9 to 1.83 3
34 55 COLD TUBESHEET 3.2 8
2.38 3
34 56 COLD TUBESHEET 1.8 22 1.95 3
34 56 COLD TUBESHEET 3.3 12 1.87 3
34 57 COLD TUBESHEET 1.8 12 3.65 3
34 57 COLD TUBESHEET 3.0 6
3.73 3-34 58 HOT TUBESHEET 1.6 39 1.58 l
3 34 58 COLD TUBESHEET 1.6 12 3.27 3
34 59 COLD TUBESHEET
!.9 31 0.83 3
34 59 COLD TteESHEET 2.4 12 1.15 3
34 60 HOT TUBEdi;ES T 2.4 14 0.89 3
34 60 COLD TUBESHEET 1.4 36 1.69 l
3 34 60 COLD TUBESHEET 2.7 14 0.56 3
34 61 COLD TUBESHEET 1.3 30 1.76 3
34 61 COLD TUBESHEET 2.1 18 1.69 3
34 62 COLD TUBESHEET 1.6 48 0.62 1
3 34 62 COLD TUBESHEET 2.2 19 2.64 j
3 34 63 COLD TUBESHEET 0.8 37 1.12 3
34 63 COLD TUBESHEET 2.1 17 1.30 3
34 64 HOT 4TH AVB 0.0 1
4.18 3
34 64 COLD TUBESHEET 0.5 22 1.76 3
34 65 COLD TUBESHEET 1.0 33 0.71 3
34 66 HOT EtEl AVB 0.0 16 6.34 3
34 66 COLD TUBESHEET 0.4 30 1.69 3
34 66 COLD TUBESHEET 1.9 24 1.23 3
34 67 HOT 4TH AVB 0.0 7
2.63 3
34 67 COLD TUBESHEET 0.5 25 1.49 3
34 68 HOT TUEESHEET 1.4 21 0.93 3
34 68 HOT TUBESHEET 1.7 9-1.11 3
34 68 HOT 3RD AVB 0.0 1
2.62 3
34 68 COLD TUBESHEET 1.7 10 1.!!
3 34 70 COLD TUBESHEET 1.0 5
1.00 3
34 72 HOT TUBESHEET 0.7 6
2.26 3
34 72 COLD TUBESHEET 2.5 17 0.64 3
34 73 HOT 2tm AVB 0.0 7
3.41 3
34 73 COLD TUBESHEET 1.4 5
2.44 3
34 75 HOT 3RD AVB 0.0 29 5.24 3
34 83 HOT IST AVB 0.0 14 2.97 3
34 83 HOT IST AVB 0.0 7
4.72 3
34 84 HOT TUBESHEET 4.9 11 0.99 3
35 30 COLD TUBESHEET 4.8 5
2.10 a
SUtttLRT OF CT 1536 EDDT CURRENT IHSFECTION DATA 0:21 WE0t3ESDAT, MARCH 5, 1986 33 LISTItt3 0F ALL TLEE FLAWS FCR STEAt1 GEHEIATOR 83 STEAt1 GEHERATOR ROW COLLRN LOC FLAW LOCATIDH FLAW H'EIGHT IIHCHESI FLAW SIZE 1%)
DEFECT VOLTAGE 3
35 33 COLD TUBESHEET 1.2 38 1.06 3
35 35 COLD TUBESHEET 1.6 31 1.01 3
35 36 COLD TUBESHEET 1.8 27' O.54 3
35 38 COLD TUBESHEET 1.7 16 1.21 3
35 39 COLD TUBESHEET 1.2 25 1.28 3.
35 39 COLD TUBESHEET 4.2 8
0.51 3
35 40 HOT TUBESHEET 1.1 33 0.55 3
35 40 COLD TUBESHEET 2.4 28 0.63 3
35 41 HOT TUBESHEET 2.5 7
2.49 3
35 44 COLD TUBESHEET 2.2 28 0.93 3
35 45 HOT 270 AVB 0.0 5
6.21 3
35 45 COLD TUBESHEET 0.6 40 1.43 3
35 45 COLD TUBESHEET 2.2 18 0.72 3
35 46 HOT 2tm AVB 0.0 4
4.07 3
35 46 HOT 3RD AVB 0.0 12 2.08 3
35 46 COLD TUBESHEET 1.4 23 2.04 3
35 47 COLD TUBESHEET 1.1 27 1.76 3
35 48 COLD TUBESHEET 0.6 17 2.94 3
35 49 COLD TUBESHEET 1.2 28 2.52 3
35 50 COLD TUBESHEET 1.2 17 2.54 3
35 51 COLD TUBESHEET 1.2 17 2.91 3
35 52 HOT 2HD AVB 0.0 26 4.28 3
35 52 HOT 3RD AVB 0.0 6
7.80 3
35 52 COLD TUBESHEET 3.1 22 2.96 3
35 53 HOT TUBESHEET 2.4 35 0.73 3
35 53 HOT TUBESHEET 3.9 4
2.04 3
35 53 COLD TUBESHEET 1.1 34 1.26 3
35 53 COLD TUBESHEET 3.0 22 1.40 3-35 54 COLD TUBESHEET 2.3 39 0.90 3
35 54 COLD TUBESHEET 3.3 15 0.84 3
35 55 HOT TUBESHEET 1.5 15 2.17 3
35 55 COLD TUBESHEET 1.7 26 1.89 3
35 55 COLD TUBESHEET 4.1 2
1.80 3
35 56 COLD TUBESHEET 1.9 17 2.40 3
35 57 COLD TUBESHEET
!.5 23 4.04 3
35 58 COLD TUBESHEET 2.1 30 1.55 3
35 59 COLD TUBESHEET 2.1 35 1.13 3
35 59 COLD TUBESHEET 3.4 10 3.47 3
35 60 COLD TUBESHEET 1.2 37 0.61
-3 35 60 COLD TUBESHEET 2.1 16 2.85 3
35 61 COLD TUBESHEET 1.5 25 1.85 3
35 62 COLD TUBESHEET 1.2 29 0.92 3
35 62 COLD TUBESHEET 2.1 13 1.65 l
3 35 63 COLD TUBESHEET 0.8 33 1.85 3
35 64 HOT 4TH AVB 0.0 1
6.05 3
35 64 COLD TUBESHEET 1.3 28 2.59 3
35 65 COLD TUBESHEET 0.7 35 3.44 3
35 66 COLD TUBESHEET 0.6 20 2.22 3
35 68 COLD TUBESHEET 3.5 3
1.88 3
35 70 COLD TUBESHEET 1.0 22 2.93 3
35 71 HOT 2t K) AVB 0.0 29 3.51 3
35 71 COLD TUBESHEET 0.8 2
3.11 3
35 73 HOT 4TH AVB 0.0 27 6.72 3
35 75 HOT 2HD AVB 0.0 11 3.12
Sur914RT OF CT 1986 EDOT CURRENT INSPECTI0tt DATA 0:21 WEDHESDAT. MARCH 5. 1986 34 a
LISTItG OF ALL TUBE FLAWS FOR STEAN GEHERATOR 03 STEAN GENERATOR ROW COLUtti LOC FLAW LOCATION FLAW HEICAIT IIHCHES)
FLAW SIZE 1%)
DEFECT VOLTAGE 3
35 75 HOT
.3RD AVB 0.0 11 6.50 3
35 75 HOT 4TH AVB 0.0 10 6.00 3
35 76 HOT 4TH AVB 0.0 9,
2.02 3
35 77 HOT IST AVB 0.0 9
4.44 3
35 77 HOT 2HD AVB 0.0 29 7.09 3
35 77 HOT 3RD AVB 0.0 5
3.59 3
35 80 HOT IST AVB 0.0 9
2.33 3
35 80 HOT 4TH AVB 0.0 6
4.23 3
35 82 HOT IST AVB 0.0 8
2.02 3
35 82 HOT 3RD AVB 0.0 9
2.76 3
35 83 HOT IST AVB 0.0 1
3.45 3
35 84 HOT IST'AVB 0.0 30 4.30 3
35 85 HOT IST AVB 0.0 5
5.05 3
3b 29 COLD TUBESHEET 2.2 4
2.57 3
36 32 HOT 2HD AVB 0.0 11 2.04 3
36 34 COLD TUBESHEET 2.1 24 1.28 3
36 35 COLD TUDESHEET 1.2 28 0.28 3
36 36 COLD TUBESHEET 1.2 8
1.53 3
36 38 COLD TUBESHEET 0.8 19 2.34 3
36 38 COLD TUBESHEET 1.9 16 1.08 3
36' 39 HOT TUBESilEET 1.8 4
1.14 3
36 39 COLD TUBESHEET 0.3 55 0.57 3
36 39 COLD TUBESHEET 0.3 52 0.54 3
36 39 COLD TUBESHEET 2.8 15 0.24 3
36 40 COLD TUBESHEET 0.8 23 0.90 3
36 40 COLD TUBESHEET 1.7 17 1.56 3
36 41 HOT TUBESHEET 2.5 6
3.09 3
36 41 COLD TUBESHEET 2.3 15 0.93 3
36 42 COLD TUBESHEET 1.4 25 1.53 3
36 43 COLD TUBESHEET 0.7 33 1.07 3
36 43 COLD TUBESHEET 2.3 29 0.65 3
36 44 COLD TUBESHEET 1.5 29 0.43 3
36 45 COLD TUDESHEET 0.8 36 0.69 3
36 45 COLD TUBESHEET 1.3 10 1.05
)
36 46 HOT TUBESHEET 1.6 12 1.25 3
36 46 COLD TUBESHEET 0.8 34 1.73 3
36 46 COLD TUBESHEET 1.6 27 1.05 3
36 48 COLD TUBESHEET 1.3 22 1.95 3
36 49 COLD TUBESHEET 1.1 27 1.75 3
36 50 COLD TUBESHEET 2.6 40 0.43 3
36 51 COLD TUBESHEET 0.9 19 3.31 3
36 52 COLD TUBESHEET 1.0 23 4.29 3
36 53 HOT 210 AVB 0.0 2
5.70 3
36 53 COLD TUBESHEET 1.7 39 0.64 3
36 54 COLD TUBESHEET 1.5 17 1.19 3
36 54 COLD TUBESHEET 3.0 17 0.87 3
36 55 HOT 3RD AVB 0.0 1
6.14 3
36 55 COLD TUBESHEET 1.9 33 0.91 3
36 56 COLD TUBESHEET
-1. 3 26 3.27 3
36 56 COLD TUBESHEET 1.8 25 0.86 3
36 57 COLD TUBESHEET 1.5 44 1.21 3
36 58 COLD TUBESilIET 1.6 30 2.83 3
36 59 C0tD TUBESHEET 1.3 22 2.40 3
36 60 COLD TUBESHEET 0.8 28 3.08
SUrt1ARY OF CT 1986 ED0Y CURRENT INSPECTION DATA 0:21 NEDHESDAY. MARCH 5. 1986 35 a-LISTIt'G OF ALL TUBE FLAWS FOR STEArt GENEIATOR 83 STEAN GENERATOR ROW COLUr#4 LOC FLAW LOCATIDH FLAW HEIGHT (INCHESI FLAW SIZE EXl DEFECT VOLTAGE 3
36 60 COLD TUBESHEET 1.1.
17 0.73 3
36 61 COLD TUBESHEET 0.9 33 0.50 3
36 61 COLD TUBESHEET 1.2 22 0.62 3
36 62 COLD TUBESHEET 0.4 29 2.12 3
36 63 COLD TUBESHEET 0.5 22 3.81 3
36 64 HOT 2HD AVB 0.0 1
6.74 3
36 64 HOT 3RD AVB 0.0 2
7.41
)
36 64 HOT 4TH AVB 0.0 6
4.0%
3 36 64 COLD TUBESHEET 0.8 17 4.62 3
36 65 HOT 2fe AVB 0.0 1
6.04 3
36 65 HOT 3RD AVB 0.0 9
7.33 3
36 65 COLD TUBESHEET 0.6 24 2.73 3
36 66 COLD TUBESHEET 0.5 23 1.68 3
36 68 COLD TUBESHEET 1.1 1
3.06 3
36 72 HOT 3RD AVB 0.0 5
4.39 3
36 73 HOT 2tK) AVB 0.0 7
3.31 3
36 73 HOT 3RD AVB 0.0 22 4.46 3
36 73 HOT 4TH AVB 0.0 4
5.77 3
36 75 HOT 4TH AVB 0.0 26 1.43 3
36 76 HOT 4TH AVB 0.0 4
3.65 3
37 28 COLD TUBESHEET 0.4 15 0.68 3
37 39 COLD TUBESHEET 0.4 3
1.26 3
37 42 COLD TUBESHEET 0.7 30 2.28 3
37 43 HOT TUBESHEET 0.7 IS 0.76 3
37 45 COLD TUBESHEET 0.7 11 1.33 3
37 46 COLD TUBESHEET 0.8 28 1.69 3
37 48 COLD TUBESHEET 1.6 27 1.50 3
37 50 COLD TUBESHEET 1.0 34 0.68 3
37 50 COLD TUBESHEET 1.6 2
1.84 3
37 51 COLD TUBESHEET 1.0 15 4.32 3
37 53 COLD TUBESHEET 1.2 20 3.92 3
37 53 COLD TUBESHEET 2.0 12 0.86 3
37 54 COLD TUBESHEET 1.2 20 3.48 i
3 37 55 HOT 3RD AVB 0.0 1
4.97 3
37 55 COLD TUBESHEET 1.3 17 2.27 3,
37 56 COLD TUBESHEET 1.2 17 1.56 3
37 57 COLD TUBESHEET 1.3 10 2.34 3
37 58 COLD TUBESHEET 0.8 17 3.15 3
37 59 COLD TUBESHEET 0.4 10 1.81 3
37 60 COLD TUBESHEET 0.5 19 2.96 3
37 61 COLD TUBESHEET 1.0 20 4.06 3
37 64 HOT 2iK) AVB 0.0 6
2.01 3
37 67 COLD TUBESHEET 0.8 1
2.06 3
37 80 HOT IST AVB 0.0 7
2.92 3
38 44 COLD 10BESHEET 0.3 18 0.89 3
38 46 COLD TUBESHEET 0.5 30 3.33 3
38 47 COLD TUDESHEET 0.9 30 1.87 3
38 48 COLD TUBESHEET 1.1 22 1.41 3
38 53 C0tD TUBESHEET 1.0 4
2.01 3
38 54 COLD TUBESHEET 1.2 13 3.97 l
3 38 55 COLD TUBESHEET 0.8 15 2.00 l
3 38 56 COLD TUBESHEET 0.4 24 0.99 3
38 56 COLD TUBESHEET 1.1 9
0.77 3
38 57 COLD TUBESHEET 0.5 12 4.16 i
e.
SUtt1ARY OF CY 1986 ED0Y CURRENT INSPECTION CATA 0:21 NE0ilESDAYe itARCH 5, 1986 36 a
LISTIt8G OF ALL TUBE FLAWS FOR STEAtt GENERATOR 83 STEAtt GENERATOR ROW COLUtti LOC FLAW LOCATION FLAW HEIGHT IIHCHESI FLAW SIZE 1%)
DEFECT VOLTAGE 3
. 38 59 COLD TUBESHEET 0.3 15 2.54 3
38 60 COLD TUBESHEET 0.3 19 1.57 3
38 71 HOT 2ie AVB 0.0 20 5.59 3
38 73 HOT 3RD AVB 0.0 23 4.46 3
38 81 HOT IST AVB 0.0 31 7.00 3
39 40 COLD TUBESHEET 1.7 8
1.23 3
39 42 COLD TUBESHEET 1.7 17 0.66 3
39 54 COLD TUBESHEET 0.8 17 1.29 3
39 55 COLD TUBESHEET 0.4 36 1.16 3
39 57 COLD TUBESHEET 0.5 18 1.98 3
39 62 HOT 4TH AVB 0.0 5
2.51 3
39 68 HOT IST AVB 0.0 1.
.7.00 3
39 68 HOT 2tE) AVB 0.0 1
8.98 3
39 69 HOT 4TH AVB 0.0 17 4.76 3
39 72 HOT 4TH AVB 0.0 26 3.80 3
39 72 COLD TUBESHEET 27.4 7
1,73 3
39 80 HOT 4TH AVB 0.0 22 4.58 3
40 58 HOT 210 AVB 0.0 2
8.06 3
40 61 HOT 4TH AVB 0.0 2
2.39 3
40 63 HOT 2HO AVB 0.0 10 2.82 3
40 68 HOT 3RD AVB 0.0 1
2.90 3
40 69 HOT 2ic AVB 0.0 1
5.84 3
40 69 HOT 3RD AVB 0.0 1
5.50 3
40 69 HOT 4TH AVB 0.0 8
3.52 3
40 70 HOT 3RD AVB 0.0 17 4.46 3
40 71 HOT 2tK) AVB 0.0 10 4.77 3
40 72 HOT IST AVB 0.0 10 1.61 3
40 72 COLD IST TSP 24.2 1.47 3
40 73 HOT IST AVB 0.0 7
5.03 3
40 73 HOT 2tm AVB 0.0 1
6.35 l
3 40 73 HOT 3RD AVB 0.0 1
5.36 3
40 77 HOT IST AVB 0.0 32 4.01 l
3 40 79 HOT IST AVB 0.0 31 9.65 l
3 41 30 HOT 4TH AVB 0.0 3
1.86 l
3 41 33 HOT IST AVB 0.0 13 2.74 l
3 41 60 HOT 3RD AVB 0.0 6
5.30 1
3 41 63 HOT IST AVB 0.0 2
2.86 3
41 63 HOT 3RD AVB 0.0 5
4.37 3
41 63 HOT 4TH AVB 0.0 6
3.17 3
41 67 HOT IST AVB 0.0 1
4.57 l
3 41 67 HOT 2tm AVB 0.0 1
8.25 3
41 69 HOT Zie AVB 0.0 1
7.14 3
41 72 HOT 2tB AVB 0.0 2
5.54 3
41 73 HOT 3RD AVB 0.0 23 5.17 3
41 73 HOT 4TH AVB 0.0 27 3.87 3
41 74 HOT IST AVB 0.0 9
3.05 3
41 74 HOT 3RD AVB 0.0 6
5.26 3
41 75 HOT IST AVB 0.0 6
1.79 3
41 75 HOT 4TH AVB 0.0 23 4.02 3
42 39 HOT 3RD AVB 0.0 3
2.73 3
42 46 HOT 4TH AVB 0.0 1
2.25 3
42 62 HOT 2t0 AVB 0.0 10 5.04 3
42 65 HOT IST AVB 0.0 34 23.56 3
42 65 HOT 2tm AVB 0.0 53 18.37
e
- Curt 1A2Y OF CY 19S6 EDDY CURPENT INSPECTION DATA 0:21 WEDHESDAY. HAPCH 5 1986 37 LISTING OF ALL TUBE FLAWS FOR STEAtt GENE 2ATOR 83 STEAN GEHERATOR ROW COLUt94 LOC FLAW LOCATION FLAW HEIGHT (INCHES)
FLAW SIZE (%1 DEFECT VOLTAGE 3
42 65 HOT 3RD AVB 0.0 46 16.79 3
42 65 HOT 4TH AVB
- 0.0 44 24.06 3
42 67 HOT IST AVB 0.0 1
7.42 3
42 68 HOT IST AVB 0.0 1
4.42 3
42 71 HOT IST AVB 0.0 1
3.61 3
42 73 HOT 3RD AVB 0.0 12 4.47 3
42 73 HOT 4TH AVB 0.0 9
2.30 3
42 74 HOT 4TH AVB 0.0 15 4.05 3
42 75 HOT 4TH AVB 0.0 7
5.17 3
42 76 HOT IST AVB 0.0 5
4.21 3
42 76 HOT 4TH AVB 0.0 20 3.83 3
43 63 HOT 210 AVB 0.0 2
5.08 3
43 63 HOT 3RD AVB 0.0 1
2.43 3
43 65 HOT IST AVB 0.0 17 10.76 3
43 65 HOT 2HD AVB 0.0 24 16.20 3
43 65 HOT 3RD AVB 0.0 12 13.87 3
43 65 HOT 4TH AVB 0.0 17 11.47 3
45 39 COLD TUBESHEET 1.7 2
1.22 3
45 43 COLD TUBESHEET 0.4 2
2.29 3
45 47 COLD TU3ESHEET 1.5 13 1.19 s
3 45 64 HOT 3RD AVB 0.0 1
2.81 3
46 34 HOT 3PD AVB 0.0 19 2.16 3
46 36 COLD TUBESHEET 7.5 23 0.55 3
46 36 COLD TUDESHEET 10.2 12 0.58 3
46 38 HOT 3RD AVB 0.0 5
3.91 3
46 40 HOT 4TH AVB 0.0 8
2.66 3
46 41 COLD TUBESHEET 1.3 8
1.09 3
46 42 COLD TUBESHEET 3.1 6
1.36 3
46 44 COLD TUBESHEET 12.7 12 1.05 3
46 60 COLD TUBESHEET 21.6 3
2.02 3
46 63 HOT 2HD AVB 0.0 2
6.80 3
46 64 HOT 4TH AVB 0.0 1
2.60 3
47 42 COLD TUBESHEET 4.7 15 1.07 3
47 46 HOT 4TH AVB 0.0 10 2.96 3
47 47 COLD TUEESHEET 40.2 4
2.74 3
47 54 HOT IST AVB 0.0 8
2.08 3
47 57 HOT 3RD AVB 0.0 3
2.75 3
47 62 HOT 4TH AVB 0.0 9
2.23 3
47 63 HOT 2tEl AVB 0.1 10 5.14 3
47 63 HOT 3RD AVB 0.0 5
3.05 3
47 63 HOT 4TH AVB 0.0 1
4.16 3
47 64 HOT ATH A\\q3 0.0 2
2.63
e ~
SUNNARY OF ALL TUBE FLAWS 0:21 WEDHESD1Y, MARCH 5. 1986 38 o
FOR CY 1986 EDDY CURRENT INSPECTIDH FOR STEAM GENERATDR 83
__==......._......___..__...__.._.......__............
l l
STEAM i
l I
l GENERATOR l l
l l___
...._l l
l l
3 l
TOTAL l
l l....==
_,__.====.....l l
l LOC l
LOC l
l 1...........................I l
l COLD l HOT l COLD l HOT l l
l______...........__....__ l l
llM1BERllM1BERltutSERitueERI l
l OF l OF l OF l OF l l
l FLAWS IFLAWS lFLAUS lFLAHS l l_
-......... ___.,____...__..l ISIZE l
l l
l l
l...._
.....I i
l l
l l<20%
l 11761 2071 1176 2071 l....___......___........__...............__....___1._____l 120-29%
l 3901 348 3901 34 l....__....=__________....__......_...................... 1l 130-39%
l 1841 ISI 1141 151 l....
..____l 140-49%
l 271 81 271 8
l......._____...........................__............_l1 l50-59%
1 81 21 al 21 l______-
---.........__________,__....,__....,_.....,_.....l 160-69%
l Il 11 I
I....__.....__.
.__......................__ll l80-89%
l Il
.l Il 1....____... _______.._..........___.... ___..____.. ___l l
190-100%
l 21
.1 21 l__.___.....____...............,_..........__.....__.....__lI l TOTAL l 1719l 2671 1719l 267l
e
SUMMARY
OF ALL TUBE FLAWS c 21 WEDNESDAYe-MARCH 5.1966 39
,., o FOR CY 1986 EDDY CURRENT INSPECTION FOR STEAN GENE 2ATOR C3
__=-_
a l
lSTEAN l l
l lGENER-l l
l l ATOR l l
l 3......
l l
l 3 ITOTAL I l......,______l l
IHureERinunBERI I
I or 1 0F 1 1
IFLAWS lFLAl!S l l-___
...........__l l SIZE l
l l
l.............
=.l l
.l I<20x 1 13s31 13s31 l..___................____ ____..............:
120-29x i
4241 4241 l____
_==..________..._......... _____l 130-39x i
1291 1291 l_..__..........____._-
=,....._,......l 140-49%
1 351 351 g__..._---
.........l Iso-59x i
nel 101 l_......_.. ___.._____....................___.l 160-69x l
21 21 l__-__
....,______l 18o-89x i
11 11 g...___
190-100x i
21 21 g...-_=___
__________________,__...........l l TOTAL l 19861 19861
_...._ _=_.............___....___...___.....__
SUMMARY
OF MAXIMUN FLAW SIZES PEJ SIDE PE2 TueE 0:21 WEONE50AY. MARCH 5.1966 (0
o 3
o.
FOR CY 1986 ED0Y CURRENT INSPECTION FOR STEAN GEHEIATOR 93 g
I I
STEAN I
1 l
l GEHERATOR. l l
l 1....______...I 1
l l
3 I
TOTAL 1
l 1..........................I I
l LDC l
LOC l
l 1..____................... 1 1
1 Coto I Hof i Coto I Hoi I i
l...................... ___I I
inuneERilAJNEERitM1EERltu1BERI I
I 0F l OF i 0F l OF l l
IFLAWS l FLAWS lFLAL S IFLAWS l l_-__..====__=
=..___........,.............,......,_-____l lSIzt i
I i
1 1
l__...
-- --_=--
--___l l
l l
l l<20%
l 8731 1551 8731 1551 1..... _______............. ___.....
.......................I l20-29%
1 3591 331 3591 331 l = = _-
--_-__,....__,......,__.......... 1
=====....______
130-39%
1 till 131 till 131 l___..._____
_==_______...............,__._....
___.1 140-49%
l 271 51 271 51 1..............................,_..........................l 150 1
51 21 51 21 l _ __-5 9%
_______................___..........._.....__..........I 16o-69%
1 11 11 11 11 l____...______.
........_____l 190-100%
1 21
.I 21
.I 1.____.--
__=--.....,_____
...____,......,__....I lioTAL i 137sl 2091 137a1 2091 a
G G
g
l o'
SUNNARY OF MLXIMUN FLAW SIZES PE2 lube 0:21 WEDt:ESCAY. NANCH 5,1986 Cl o y
'a FOR CY 1966 EDDY CURRENT IttSPECTIDH FOR STEAN GENERATOR 83
=====- ___ -._
l lSTEAN l l
l lGENER-l l
l t ATOR l l
l i.... _l l
l l 3 ITOTAL l l
l............
l lHUf1BER ltA#1CER I l
l OF I OF l l
l FLAWS lFLARS I l____.....=-
=___
,______l l5IZE l
l l
l_.....______._____......___.l l
l<20%
l 9541 9541 g...._
_ _ ________===
...._..._....l l20-29%
l 3811 3Sil l_.
= -
130-39%
l 1211 1211
- l. _=.
==.....___........____,_...._,_____.l 140-49%
l 321 321 g........___
...........l 150-59%
1 71 71 g....___..
__l l60-69%
l 21 21 g._=--
-_ ___===--
==,_..__.l 190-100%
l 21 21 g........______.....________...........,___
..l ITOTAL i 14991 14991
.GB -
o*O SUtt1CY OF TCE INSPECTI0tfS CY EXTENT 0:21 WEDtISOAY, MAPCH 5, 1966 42 o.g o FOR CY 1966 ED0Y CURRENT INSPECTION FOR STEAM GENE ATOR 83
_--_-----=_-......... =__ - _.......
gp l
l STEAN l
l l
l GENERATCR l l
l 3....._...._l l
l l
3 l
TOTAL l
l l_...____...,__......._g l
l nut 2ER OF l PU1BER OF l l
IINSPECTIONSlINSPECTIONSl
=-
l LENGTH l
l l
4 t
3.=_
__...g g
i 1
ITHIRD SUPPORT l
Il 11 3._.....__
......................____l IFOURTH SUPPORT l
Il Il l_..____
===-_-__ __- __ __
_,.........._,__.........g ITHRU U 1
981 981 l.....__-BEle
__...........___................ _.............l IFULL LENGTH l
36701 367o1 l-
__=._,...........l IToTAL 1
37701 37701 I
4 I
i m&
SutttARY OF CV 1986 EDDY CURRENT INSPECTION DATA 0:10 WEDHESDAY. MARCH 5.1986 1
LISTIr3 OF ALL TUSE FLAWS a(gg
=
FOR STEAN GEHE1ATOR N2' gg STEArt GENERATOR ROW COLutti LOC FLAW LOCATIOll FLAW HEIGHT IIHCHESI FLAW SIZE l'.I DEFECT VOLTAGE
/
2 3
47 HOT TUBESHEET 1.6 14 1.90 2
4 37 COLD TUBESHEET 1.1 21 0.78 2
4 37 COLD TUBESHEET 9.6 27 1.26 2
5 I
1.78 2
5 11 HOT TUBESHEET 3.5 6
1.!!
2 5
12 HOT TUBESHEET 1.0 11 2.56 2
5 15 COLD TUBESHEET 1.7 2.24 2
5 17 COLD 2HD TSP 20.8 7
1,44 2
5 17 COLD TUBESHEET 1.3 5
l'.48 2
5 20 COLD TUBESHEET 0.9 3
2.00 2
5 21
. COLD TUBESHEET 0.9 22 1.12 2
5 22 COLD TUBESHEET 0.9 20 2.49 2
5 25 COLD TUBESHEET 1.1 1
2.70 2
5 26 HOT TUBESHEET 3.0 3
1.90 1
2 5
30 COLD TUBESHEET 3.4 15 2.52 2
5 31 COLD TUBESHEET 2.6 31 0.93 2
5 32 HOT TUBESHEET 0.7 9
1.86 2
5 33 HOT TUBESHEET 4.5 12 1.13 2
5 35 COLD TUBESHEET 1.8 9
0.91 2
5 36 COLD TUBESHEET 2.0 1.93 2
5 37 COLD TUBESHEET 5.4 26 0.84 2
5 39 COLD TUBESHEET 1.6 36 1.03 2
5 39 COLD TUBESHEET 2.4 81 1.08 2
5 40 001D TUBFSHFFT 1.5 26
.l.22 2
5 40 COLD TUBESHEET 3.8 15 1.10 2
5 41 COLD TUBESHEET 2.0 27 1.08 2
5 42 HOT TUBESHEET 5.8 8
1.83 2
5 43 HOT TUBESHEET 1.3 19 4.13 2
5 45 COLD 2'ID TSP 19.3 16 1.58 2
5 45 COLD TUBESHEET 3.1 3.06 2
5 46 COLD TUBESHEET 2.2 21 1.16 2
5 47 COLD TUBESHEET 2.8 46 0.66 2
5 50 COLD TUBESHEET 1.2 39 0.50 2
5 50 COLD TUGESHEET 2.0 8
2.12 2
5 51 COLD TUBESHEE T 2.2 19 0.87 2
5 54 COLD TUBESHEET 1.3 19 1.99 2
5 55 HOT TUBESHEET 1.2 18 0.56 2
5 55 HOT TUBESHEET 5.9 2
2.59 i
2 5
55 COLD TUBESHEET 1.6 15 1.99 2
5 56 COLD TUBESHEET 1.2 25 2.31 l
2 5
57 COLD TUDESHEET 1.1 26 1.15 l
2 5
58 COLD TUBESHEET 1.3 10 1.55 2
5 62 HOT TUBESHEET 0.9 15 1.39 2
5 64 HOT 3PD TSP 6.6 43 1.86 2
5 64 COLD TUBESHEET 0.7 38 3.31 2
5 66 COLD TUBESHEET 1.2 17 2.60 I
2 5
67 HOT 2HD TSP 36.5 5
1.30 2
5 67 COLD TUBESHEET 0.9 12 2.39 2
5 71 HOT TUBESHEET 3.7 10 1.74 t
2 5
74 COLD TUBESHEET
!.4 14 1.56 2
5 87 COLD TUDESHEET 0.8 36 2.97 l
2 5
94 COLD 2HD TSP 29.7 14 1.74 l
2 6
2 HOT TUBESHEET 6.1 11 3.05 l
2 6
2 HOT 2HD TSP
!!.0 14 1.08 l
l
m Surt1 arf 0F CV 1986 EDDY CURRENT INSPECTIcta DATA 0:19 WEDI!EEDAY. MARCH 5, 1966 2
LISTIHG OF ALL TUBE FLAWS a
e FOR STEAN GENERATOR 82 g.
STEAM GENERATOR ROW COLutti LOC FLAW LOCATIDH FLAW HEIGHT (INCHESI FLAW SIZE IXI DEFECT VOLTAGE 2
6
-4 HOT 2HD TSP 30.7 6
1.51 2
6 HOT TUBE SHEET 1.0 3
2.20 2
6 14 COLD TUBESHEET 1.5 2.35 2
6 15 COLD TUBESHEET
!.9 11 2.90 2
6 16 COLD TUBESHEET 1.8 18 2.99 2
6 17 COLD TUBESHEET 1.9 6
3.79 2
6 21 COLD TUBESHEET 1.2 3
1.66 2 ~
6 22 COLD TUBESHEET 2.7 2
1.57 2
6 23 COLD TUBESHEET 4.1 19 1.79 2
6 26 HOT TUBESHEET 2.2 4
1.47 2
6 26 COLD TUBESHEET 1.5 16 0.94 2
6 27 COLD TUBESHEET 1.5 11 1.01 2
6 28 COLD TUBESHEET 1.6 6
1.21 2
6 29 COLD TUBESHEET 1.5 3
1.78 2'
6 30 COLD TUBESHEET 1.4 4
2.41 2
6 31 COLD TUBESHEET
!.5 20 1.19 2
6 35 COLD TUBESHEET 1.7 16 1.15 2
6 37 COLD TUBESHEET
' 5.4 18 2.21 2
6 37 COLD TUBESHEET 5.7 27 1.67 2
6 38 COLD TUBESHEET 5.6 15 1.84 2
6 39 COLD TUBE SHE E T 2.6 10 2.09 2
6 39 COLD TUBESHEET 6.1 22 4.83 2
6 40 COLD TUBESHEET 5.7 13 5.22 2
6 40 COLD TUBESHEET 6.6 21 1.15 2
6 41 HOT TUCESHEET 4.8 26 2.78 2
6 41 HOT TUBESHEET 5.7 18 1.59 2
6 42 HOT TUBESHEET 1.4 14 2.38 2
6 42 COLD TUBESHEET 4.9 15 2.96 2
6 43 COLD TUBESHEET 4.0 32 1.75 2
6 43 COLD TUBESHEET 4.9 13 1.62 2
6 45 COLD TUBESHEET 3.4 19 1.04 2
6 48 COLD TUBESHEET 2.9 IS 3.04 2
6 49 COLD TUBESHEET 1.8 25 2.76 2
6 49 COLD TUBESHEET 2.8 13 3.37 2
6 50 COLD TUBESHEET 2.1 23 1.81 2
6 51 HOT TUBESHEET 6.7 14 1.36 2
6 51 COLD TUBESHEET 1.3 32 1.24 2
6 51 COLD TUBESHEET
!.8 27 1.47 2
6 52 COLD TUBESHEET 1.5 20 1.45 2
6 54 COLD TUBESHEET 1.2 33 1.36 2
6 54 COLD TUBESHEET 2.3 18 2.31 2
6 55 HOT TUEESHEET 7.0 to 1.04 2
4 55 COLD TUBESHEET 2.2 25 1.21 2
6 Sh HOT 3RD TSP 2.1 35 1.36 2
6 56 COLD TUBEStiEE T 2.4 39 2.86 2
6 57 COLD TUDESHEET 2.4 28 4.23 2
6 SS HOT 3PD TSP 2.4 21 1.29 2
6 55 COLD TUDESHEET 2.1 13 2.44 2
6 60 Cold tuEESHEET 2.3 6
1.63 2
6 61 HOT TUBE 5HEET 0.5 13 3.09 2
6 65 HOT TUBESHEET 1.0 20 4.54 2
6 65 COLD TUBESHEET 1.7 22 1.39 2
6 66 HOT luBELitEE1 0.9 25 3.46 2
6 66 HOT TUDESHEET 3.1 17 2.96 L-.
Sutt1Apf 0F CV 1986 EDDY CURRENT INSPECTION CATA 0:19 NEDB250 AY, itARCH 5,1986 3'
LIST!tG OF ALL TUEE FLAWS FOR STEAff CENCATOR 02 STEAn CDRWATOR RDW COLUNH LOC FLAW LOCATION FLAW NEIGHT IIHCHESI FLAW SIZE tXI DEFECT VOLTAGE 2
6 66 HOT 3RD TSP 2.3 30 1.45 2
6 66 HOT 3RD TSP 4.7 9
2.17 2
6 66 COLD TUBESHEET 1.6 23 3.10 2
6 67 HOT TUBESHEET 3.5 3
2.30 2
6 67 COLD TueE5HEET 0.8 1
3.22 2
6 72 COLD TutESHEET 1.8 22
~3.43 2
6 72 COLD TUBESHEET 2.8 5
1.24 2
6 73 COLD TUBESHEET 1.6 3
4.22 2
6 75 COLD TUBESHEET 1.3 7
3.90 2
6 76 COLD TUBESHEET I.3 to 2.37 2
6 76 COLD TUBESHEET 1.8 17 0.89 2
6 77 COLD TUBESHEET 3.3 24 2.69 2
6 79 COLD TUBESHEET 1.5 22 1.77 2
6 81 COLD TUEESHEET 1.5 9
2.65 2
6 82 COLD TUBESHEET 1.1 9
4.06 2
6 83 COLD TUBESHEET 1.5 4
2.19 i
2 4
86 HOT TUBESHEET 1.1 17 5.03 l
2 6
94 HDT 3RD TSP 17.0 13 2.40 2
7 11 COLD TUBESHE ET 1.0 19 1.26 2
7 12 HOT TUBESHEET 1.3 17 2.00 2
7 13 COLD TUBESHEET 1.7 8
1.42 2
7 14 COLD TUBESHEET 2.0 12 3.08 2
7 15 COLD TUEESHEET 2.2 4
2.19 2
7 16 COLD TUBESHEET 2.2 5
4.29 2
7 17 NOT TUBE SHEE T 0.8 4
1.11 2
7 17 COLD TUBESHEET 0.9 2
1.62 2
7 17 COLD TUBESHEET 2.3 5
3.52 2
7 18 COLD TUBESHEET 2.9 13 4.05 2
7 19 COLD TUBESHEET 1.5 7
2.59 2
7 19 COLD TUBESHEET 3.1 11
'3.15 2
7 20 COLD TUEESHEET 2.6 6
2.78 2
7 21 COLD TUBESHEET 2.6 12 2.77 2
7 22 COLD TUBESHEET 1.3 14 2.21 2
7 22 COLD TUBESHEET 2.7 22 2.68 2
7 22 COLD TUBESHEET 3.1 17 1.32 2
7 23 COLD TUBESHEET 2.6 22 3.07 7
24 COLD TUBESHEET 1.1 7
1.41 2
7 25 COLD TUBESHEET 1.4 le 2.13 2
7 26 COLD TUBE SHEET 1.5 26 1.20 2
7 27 COLD TUBESHEET 1.6 20 2.47 2
7 27 COLD TUBESHEET 2.6 6
1.22 2
7 28 COLD TUBESHEET 2.2 21 0.57 2
7 29 COLD TUBESHEET 1.2 9
5.77 2
7 30 COLD TUCESHEET 2.3 14 1.84 2
7 31 COLO TUBESHEET 1.2 22 1.89 2
7 31 COLD TUBESHEET 2.4 9
1.77 2
7 32 CotD TueESHEET 1.3 26 2.62 2
7 35 COLD TUBE SHEE T 3.9 10 1.57 2
7 36 COLD TUBESHEET 3.6 14 2.16 2
7 37 COLD 10BESHEET 3.7 10 2.98 2
7 38 COLD TueESHEET 5.3 12 4.11 2
7 40 COLD TUBESHEET 3.0 9
4.56 2
7 41 COLD TUBESHEE T 5.4 17 3.23 2
7 42 COLD TVEESHEET 5.C 17 2.32 6
d SLA01 ART OF C1 1966 EDOT CUPRENT INSPECTICH D'.TA 0:10 WEl'HESDAT.11 ARCH 5.1986 4
LISTIHG OF ALL TUBE FLAWS FOR STEAM GENE!ATOR 82 STEAtt GENERATOR ROW COLLM4 LOC FLAW LOCATIott FLAW HEIGHT (1HCHESI FLAW SIZE (%I DEFECT VOLTAGE 2
7 43 COLD TUBESHE2T 3.7 15 1.35 2
7 44 HOT TUBES:tEET I.3 15 1.05 2
7 44 COLD TUBESHEET 4.5 7
2.07 t
2 7
46 COLD TUBESHEET 3.1 16 1.53 2
7 47 COLD TUBESHEET 3.0 23 0.69 2
7 48 COLD TUBESHEET 2.7 26 2.!!
2 7
48 C0tD TUBESHEET 4.2 13 1.28 2
7 49 Coto TUBESHEET 2.3 36 1.86 2
7 49 COLD TUBESHEET 4.2 14 1.05 2
7 50 HOT TUBESHEET 4.9 34 1.37 2
7 50 COLD TUBESHEET 3.8 27 0.69 2
7 51 COLD TUBESHEET 2.0 29 2.76 2
7 52 COLD TUBESHEET 1.0 38 1.86 2
7 52 COLD TUBESHEET 2.4 3
1.44 2
7 53 COLD TUBESHEET 2.7 25 1.92 2
7 54 COLD TUBESHEET 2.2 Il 3.64 2
7 54 COLD TUBESHEET 2.5 31 0.86 2
7 55 COLD TUBESHEE T 2.9 26 2.77 2
7 55 COLD TUBESHEET 4.0 15 1.03 2
7 56 HOT TUBESHEET 4.3 18 1.23 2
7 56 COLD TUBESHEET 2.7 34 3.67 2
7 57 COLD TUBESHEET 2.8 26 7.51 2
7 58 COLD TUBESHEET 2.7 32 2.57 2
7 63 COLD TUBESHEET 1.4 19 1.15 2
7 64 COLD.
TUBESHEET 3.1 19 4.79 2
7 66 COLD TUBESHEET 1.6 20 2.98 2
7 67 COLD TUBESHEET 1.4 11 1.75 2
7 72 HOT TUBESHEET 3.4 2
1.86 2
7 72 COLD TUBESHEET 1.7 15 4.60 2
7 73 COLD TUBESHEET 3.9 11 3.95 2
7 74 COLD TUBESHEET
!.3 10 3.58 2
7 75 COLD TUBESHEET 1.1 14 3.86 2
7 76 COLD TUBESHEET I.0 18 1.22 2
7 76 COLD TUBESHEET 1.6 15 3.55 2
7 77 COLD TUBESHEET 1.7 25 2.70 2
7 78 COLD TUBESHEET 1.5 20 2.88 2
7 79 COLD TUBESHEET 1.6 17 2.96 2
7 80 COLD TUBESHEET 2.5 8
2.13 2
7 82 COLD TUBESHEET 1.4 18 0.84 2
7 83 COLD TUBESHEET 1.0 26 1.98 2
7 83 COLD TUBESHEET 2.0 17 1.08 2
7 84 COLD TUBESHEET 2.7 17 0.97 2
8 3
HOT TUBESHEET 6.5 7
1,46 2
8 13 colo TUBESHEET 1.8 3
0.94 2
8 14 COLD TUEESHEET 2.0 12 2.66 2
8 15 Cot 0 TUBESHEET 2.2 15 1.42 2
8 16 COLD TUBESHEET 2.5 17 3.!!
2 8
17 COLD TUBESHEET 2.5 5
2.49 2
8 18 HOT TUBESHEET 2.2 52 9.70 l
2 8
18 COLD TUBESHEET 2.2 17 4.65 l
2 8
18 COLD TUBESHEET 2.8 19 4.75 2
8 19 COLD TUBESHEET 2.9 17 3.10 2
8 20 COLD TUDESHEET 2.6 14 2.47 2
8 21 COLD TUBESHEET I.4 22 1.64
SLW9 TART OF CT 1986 EDOT CLAIRENT INSPECTION DATA 0:19 HEDHESDAV, MARCH 5,1986 5
LISTIt:3 OF ALL TUBE FLAWS 8
FOR STEAM GENCATOR 82 STEAM GENERATOR
- 04 COLUMN LOC FLAW LOCATION FLAW HEIGHT IINCHESI FLAW SIZE 1%)
DEFECT VOLTAGE 2
8 22 COLD TUBESHEET 2.7 15 2.32 2
8 23 COLD TUBESHEET 2.9 17 2.57 2
8 24 COLD TUBESHEET 1.9 2
2.38 2
8 24 COLD TUBESHEET 2.9 21 1.35 2
8 25 COLD TUBESHEET 1.7 7
4.22 2
8 26 COLD TUBESHEET 3.4 22 10.72 2
8 27 COLD TUBESHEET 1.6 16 2.48 2
8 27 COLD TUBESHEET 3.4 5
2.45 2
8 28 COLD TUBESHEET 1.3 12 3.52 2
8 29 COLD TUBESHEET 1.4 15 6.21 2-8 30 COLD TUBESHEET 1.9 26 3.85 2
8 31 COLD TUBESHEET 27 1.74 2
8 31 COLD TUBESHEET 2.2 19 2.87 2
8 32 COLD TUBESHEET 2.4 29 1,68 2
8 33 COLD TUBE 5HEET 2.4 11 2.16 2
8 34 COLD TUBESHEET I.!
13 3.63 2
8 34 COLD TUBESHEET 2.9 21 2.32 2
8 35 COLD TUBESHEET 3.1 26 1.87 2
8 36 COLD TUBESHEET 1.8 36 1.84 2
8 36 COLD TUBESHEET 5.7 12 1.26 2
8 38 COLD TUBESHEET 4.5 8
1.64 2
8 39 COLD TUBESHEET 3.8 to 1.39 2
8 39 COLD TUBESHEET 4.8 17 2.51 2
8 40 COLD TueESHEET 3.6 19 0.88 2
8 41 COLD TUBESHEET 4.9 20 2.69 2
8 42 COLD TUBESHEET 3.1 17 1.14 2
8 43 COLD TUBESHEET 4.9 26 1.69 2
8 44 COLD TUBESHEET 4.6 13 1.94 2
8 46 COLD TUBESHEET 4.8 4
1.95 2
8 47 COLD TUBESHEET 2.8 7
1.72 2
8 48 COLD TUBESHEET 3.7 22 0.94 2
8 49 HOT TUBESHEET 5.7 20 1.12 2
8 49 COLD TUBESHEET 3.1 34 0.80 2
8 49 COLD TUBESHEET 4.3 8
1.03 2
8 50 COLD TUBESHEET 3.6 24 2.24 2
8 50 COLD TUBEShEET 4.6 16 1.17 2
8 51 COLD TUDESHEET 3.3 34 2.56 2
8 52 COLD TUBESHEET 3.3 21 2.08 2
6 53 COLD TUBESHEET 1.7 13 1.60 2
6 53 COLD TUBESHEET 2.8 26 0.94 2
8 54 COLD TUBESHEET 1.4 39 0.82 2
8 54 COLD TUBESHEET 4.0 6
1.45 2
8 55 HOT TUBESHEET 0.7 13 0.84 2
8 55 COLD TUBESHEET 2.7 15 1.24 2
8 55 COLD TUBESHEET 3.5 19 0.63 2
8 56 HOT 3RD TSP 2.9 13 2 1.91 2
8 56 COLD TUBESHEET 2.7 15 3.41 2
8 57 COLD TUBESHEET 2.7 22 '
3.95 2
8 SS COLD TUBESHEET 2.2 19 O.94 2
8 59 COLD TUBESHEET 2.3 26 1.40 2
8 59 COLD TUBESHEET 3.5 14 5.54 2
8 60 COLD TUDESHEET 3.6 49 1.33 2
8 61 COLD TUBESHEET 2.0 13 1.81 2
8 61 COLD TUBESHEET 3.9 8
2.38 e
SLRf1ARY OF CY 1986 EDOT CURRENT INSPECTION CATA 0:19 WE0tESO AY.11 ARCH 5.1966 6
LISTIt3 0F ALL TUBE FLAWS FOR STEAtt GEIECATOR 82 STEAM GENERATOR ROW COLLR94 LOC FLAW LOCATION FLAW HEIGHT IIHCHESI FLAW SIZE (%)
DEFECT VDLTAGE 2
8 62 COLD TUBESHEET 1.7 17 1.79 2
8 62 COLD TUEESHEET 3.3 9
2.11 2
8 63 COLD TUBESHEET 1.6 5
4.21 2
8 64 COLD TUBESHEET 2.9 13 1.11 2
8 65 COLD TUBESHEET 1.7 28 1.47 2
8 65 COLD TUBESHEET 2.1
' 21 1.42 2
8 66 COLD TUBESHEET 1.7 18 3.45 2
8 67 COLD TUBESHEET 1.7 20 2.10 2
8 67 COLD TUBE SHEET 2.6 6
2.87 2
8 68 COLD TUBE SHEET 1.8 10 1.70 2
8 69 COLD TUBESHEET 0.5 27 4.51 2
8 71 HOT 2HD TSP 30.7 16 1.24 2
8 71 COLD TUEESHEET 0.3 79 3.30 2
8 72 COLD TUBESHEET 1.4 16 1.49 2
8 73 COLD TUBESHEET 1.6 2.33 2
8 74 COLD TUBESHEET 0.5 13 2.78 2
8 75 COLD TUBESHEET 1.6 8
4.05 2
8 76 COLD TUBESHEET 1.1 23 5.61 2
8 76 COLD TUBESHEET 2.2 22 3.53 2
8 77 COLD TUBESHEET 1.2 34 1.77 2
8 77 COLD TUBESHEET 2.1 18 5.81 2
8 78 COLD TUBESHEET 1.2 20 3.45 2
8 79 COLD TUBESHEET 1.0 10 3.76 2
8 79 COLD TUBESHEET 2.4 19 2.67 2
8 80 COLD TUBESHEET 1.2 22 4.67 2
8 80 COLD TUBE SHE E T 2.5 19 1.25 2
6 81 COLD TUBESHEET 1.1 26 3.38 2
8 82 COLD TUBESHEET 1.1 31 4.74 2
8 82 COLD TUBESHEET 2.4 24 3.89 2
6 83 COLD TUBESHEET 1.2 26 3.57 2
8 83 COLD TUBESHEET 1.8 8
1.77 2
8 84 CotD TUBESHEET 1.9 17 1.27 2
9 14 COLD TUBESHEET 1.9 9
3.23 2
9 15 COLD TUBESHEET 2.4 9
3.84 2
9 16 COLD TUBESHEET 2.3 10 4.34 2
9 17 COLD TUBESHEET 2.2 15 6.06 2
9 18 COLD TUBESHEET 1.8 36 3.89 2
9 19 COLD TUBESHEET 1.6 14 3.16 2
9 20 COLD TUBESHEET 2.6 11 4.03 2
9 21 COLD TUBESHEET 2.9 13 3.37 2
9 22 COLD TUDESHEET 2.4 25 1.09 2
9 22 COLD TUEESHEET 3.1 9
1.43 2
9 23 COLD TUBESHEET 1.9 4
3.77 2
9 24 COLD TUBESHEET 2.8 21 2.41 2
9 25 COLD TUBESHEET 2.1 2
3.89 2
9 25 C010 TUBESHEET 3.2 7
2.79 2
9 26 COLD TUDESHEET 1.8 22 3.03 2
9 27 COLD TUBESHEET 1.5 15 2.68 2
9 27 COLD TUEESHE ET 2.5 17 3.52 2
9 28 COLD TUBESHEET 1.7 37 C.55 2
9 28 COLD TUBESHEET 3.4 8
6.29 2
9 29 COLD TUEESHEET 1.4 7
4.94 2
9 30 COLD TUDESHEET 1.7 21 1.23 2
9 30 COLD TUBESHEET 3.8 8
0.91
m SUNP*AllT OF CT 1986 EDOT CLENFENT INSPECTION tlATA 0:10 NEDt2SDAY, MARCH 5. 1906 7
LI2TIHG OF ALL TUBE FLAWS e
d FOR STEAM GEHECATOR 92 STEAM GENERATOR ROM COLUP94 LOC FLAN LOCATION FLAW HEIGHT IINCHESI FLAW SIZE (%)
DEFECT VOLTAGE 2
9 31 Cot 0 TUBESHEET 3.9 18 2.81 2
9 31 COLD TUBESHEE' 2.0 25 9.98 2
9 32 COLD TUBESHEET
!.0 28 0.96 2
9 32 COLD TUBESHEET 2.4 9
4.71 2
9 33 COLD TUBESHEET 2.9 21 0.64 2
9 33 COLD TUBESHEET 3.8 16 1.81 2
9 34 COLD TUBE SHEE T 3.9 5.03 2
9 34 COLD TUBESHEET 1.4 IS 3.46 2
9 34 COLD TUBESHEET 3.0 IS 3.85 2
9 35 COLD TUBESHEET 2.9 33 0.89 2
9 35 COLD TUBESHEET 3.5 16 1.12 i
2 9
36 COLD TUBESHEET 2.5 12 3.21 2
9 38 COLD TUBESHEET 3.2 15 2.01 2
9 38 COLD TUBESHEET 4.2 IS 1.49 2
9 39 COLO TUBESHEET 5.2 23 3.13 2
9 40 COLD TUBESHEET 5.1 15 3.73 2
9 41 HOT TUBESHEET 1.6 5
1.90
?
9 41 COLD TUBESHEET 4.9 11 2.99 2
9 42 COLD TUBESHEET 4.9 12 1.80 2
9 43 COLD
.TUBESHEET 5.1 17 3.80 2
9 44 COLD TUBESHEET 0.5 19 0.87 2
9
'5 COLD TUBESHEET 4.6 7
1.70
)
1 2
9 47 COLD TUBESREET 2.6 29-0.70 2
9 47 COLD TUBESHEET 4.9 28 0.74 2
9 48 COLD TUBtSHEET 4.6 8
2.25 2
9 49 COLD TUBESHEET 4.3 20 1.21 2
9 50 COLD TUBE SHEET 3.5 11 1.12 7
2 9
58 COLD TUBESHEET 3.9 26 1.44 i
2 9
51 COLD TUBESHEET 5.0 13 0.80 2
9 52 COLD TUBESHEET 4.0 17 1.45 2
9 53 COLD TUBESHEET 2.5 49 1.14 2
9 53 COLD TUBESHEET 3.5 23 1.03 2
9 54 COLD
'TUBESHEET 2.2 29 0.89 3
2 9
54 COLD TUBESHEET 3.0 15 1.78 2
9
$5 COLD TUBESHEET 3.3 22 2.14 2
9 55 COLO TIBESHEET 3.6 18 2.40 l
2 9
56 COLD TUBESHEET 3.8 27 1.08 t
2 9
57 CotB TUBESHEET 3.4 26 3.36 2
9 59 Coto TUBESHEET 2.4 20 2.36 2
9 59 COLD TUDE SHEE T 3.0 10 1.14 i
2 9
60 COLD TUBESHEET 3.4 22 2.17 2
9 61 COLD TUBESHEET 3.4 14 1,92 2
9 62 COLD TUBESHEET 3.0 12 2.36 2
9 64 COLD TUBESHEET 2.1 21 1.91 b
2 9
65 COLD TUEESHEET
!.9 21 2.12 2
9 65 CotD TUBESHEET 2.6 12 1.96 2
9 66 COLD TUDESHEET 1.4 13 1.09 2
9 67 COLD TUBESHEET 2.2 25 1.88 2
9 68 COLD TUBE SHEE T 1.4 43 2.01 2
9 68 COLD TUBESHEET 2.6 6
1.86 2
9 69 COLO TUBESHEET 0.6 21 5.70 i
2 9
69 COLO TUBESHEET
!.4 13 1.80 2
9 70 COLD TUBESHEET 0.3 25 9.68 2
9 70 COLD TUBESHEET 3.6 25 2.74
. ~.
i Sure1ARY OF CT 1986 EDDT CUR 9ENT INSPECTION OtTA 0:19 WEDfESD AT ItARCH 5.1986 8
LTSTIttG OF ALL TUBE FLAWS e
FOR STEAM GENELiTOR 02 STEAM GENERATOR ROW COLT #94 LOC FLAW LOCATION FLAW HEIGHT IINCHESI FLAN SIZE (%)
DEFECT VOLTAGE 2
9 71 COLD TUBESHEET 0.2 39 4.23 2
9 71 COLD TUBESHEET 1.9 11 2.11 2
9 72 COLD TUBESHEET 0.8 9
4.56 2
9 72 COLD TUBESHEET 1.9 13 1.93 1
2 9
73 COLD TUBESHEET I.7 14 5.69 2
9 74 COLD TUBESHEET 1.9 20 4.98 2
9 75 COLD TUBESHEET 0.5 15 8.33 i
2 9
75 COLD TUBESHEET 1.4 16 2.59 2
9 76 COLD TUBESHEET 2.2 19 1.94 2
9 77 COLD TUBESHEET 1.3 33 5.81 2
9 78 COLD TUBESHEET
!.4 27-7.04 l
2 9
79 COLD TUBE 5HEET 1.1 to 4.48 2
9 79 COLD TUBESHEET 2.7 2
1.73 2
9 80 COLD TUBESHEET 1.2 28 6.31 2
9 80 COLD TUBESHEET 2.8 19 0.73 2
9 81 COLD TUBESHEET 1.2 23 1.69 2
9 of COLD TUBESHEET 2.0 17 1.52 2
9 82 COLD TUBESHEET 2.4 22 1.99 2
9 83 COLD TUBESHEET 1.0 17 1.41 2
9 83 COLD TUBESHEET 2.0 13 1.10 2
9 84 COLD TUBESHEET 1.5 le 2.99 I
2 9
86 COLD TUBESHEET 0.3 14 1.72 I
2 9
88 HOT 3RD TSP 4.1 40 1.03 2
10 12 HOT TUBESHEET 0.9 32 7.61 2
10 12 HOT TUBESHEET 1.5 17 3.62 2
10 14 COLD TUBESHEET 2.1 18 3.19 2
10 IS HOT TUBESHEET 1.6
- 1. 94 l
2 to 15 COLD TUBESHEET 1.1 15 5.29 2
le 16 COLD TUBESHEE T 2.1 13 3.33 2
10 17 COLD TUBESHEET 2.1 15 5.40 2
10 18 COLD TUEESHEET I.3 24 0.97 2
10 18 COLD TUBESHEET 1.6 10 4.28 2
10 19 COLD TUBESHEET 3.1 19 2.21 2
10 20 COLD TUBESHEET 2.8 29 3.45 2
10 21 COLD TUBE SHE ET 3.2 7
3.32 1
2 10 22 COLD TUBESHEET 2.9 7
2.13 2
10 22 COLD TUBESHEET 3.4 5
1.75 l
2 le 23 COLD TUBESHEET 2.0 26 1.39 l
2 10 23 COLD TUBESHEET 3.3 17 3.23-1 2
10 24 COLD TUBESHEET l.8 9
2.73 j
2 le 24 COLD TUBESHEET 3.7 12 1.47 2
10 25 COLD TUBESHEET 2.0 9
3.12 2
10 25 COLD TUBESHEET 3.4 3.87 l
2 10 27 COLD TUeESHEET 1.5 22 2.30 2
10 27 COLD TUSESHEET 2.9 20 3.23 2
10 28 CotD TUBESHEET 1.8 27 1.38 2
10 28 COLD TUBESHEET 3.1 13 4.67 2
10 29 COLD TUBESHEET 3.2 36 1.75 2
10 30 COLD TutESHEET 2.0 18 7.50 2
10 31 COLD TUBE SHEE T 2.1 28 10.21 2
10 31 COLD TUBE SHE E T 3.0 28 4.72 2
10 32 COLD TUBESHEET-1.9 36 3.85 2
10 32 COLD TUEESHEET 2.7 24 6.95 2
10 33 COLD TUBESHEET 2.1 26 2.47 i
.~-
StattARY OF CY 1986 ED0Y CURRENT INSFECTION CATA 0:19 WEDt'ISOAY, MARCH Si 1986 9
LI;TIr3 0F ALL TUBE FLAWS F09 STEAN GEttE;ATOR s2 STEAN GENERATOR ROW COLUNH LOC FLAW LOCATIDH FLAW HEIGHT IIt4CHESI FLAW $1ZE 8%)
DEFECT VOLTAGE 2
10 34 COLD TUBESHEET 1.2 23 7.29 2
10 35 COLD TUBESHEET 2.1 to 3.14 2
10 35 COLD TUBESHEET 3.9 9
3.27 2
10 37 COLD TUBESHEET 0.8 20 2.32 2
10 38 COLD TUBESHEET 2.4 27 2.07 2
le 38 COLD TUBESHEET 4.4 15 1.16 2
10 39 COLD TUBESHEET 0.8 17 1.17 2
10 39 COLD TUBESHEET 4.1 16 1.87 2
10 40 COLD TUBESHEET 2.5 32 0.95 2
10 40 COLD TUBESHEET 3.8 18 1.12 2
10 41 COLD TUBESHEET 2.8 17 0.79 2
10 42 COLD TUBESHEET 4.9 9
1.48 2
10 43 COLD TUBESHEET 5.3 12 4.72 2
10 44 COLD TUBESHEET 5.4 4.54 2
10 45 COLD TUBESHEET 5.4 7
3.32 2
10 46 COLD TUBESHEET 5.4 5
2.56 2
10 47 COLD TUBESHEET 3.5 16 2.27 2
10 48 COLD TUBESHEET 4.4 19 1.29 2
10 49 HOT TUBESHEET 5.0 20 0.84 2
10 49 COLD TUBESHEET 4.1 26 0.68 2
10 50 COLD TUBESHEET 2.2 4
1.78 2
10 52 COLD TUBESHEET 1.7 3S 0.71 2
10 52 COLD TUBESHEET 4.5 21 0.74 2
10 53 HOT 3RD TSP 6.5 28 1.03 -
2 10 53 COLD TUBESHEET 1.6 25 1.59 2
10 53 COLD TUBESHEET 6.2 9
0.97 2
to 54 COLD TUCESHEET 4.8 8
1.00 2
10 55 COLD TUBESHEET 3.3 30 2.39 2
10 55 COLD TUBESHEET 5.0 5
1.36 2
10 56 COLD TUBESHLET 4.9 19 2.10 2
10 57 HOT.
TUBESHEET 1.3 14 1.35 i
2 10 57 COLD TUBESHEET 3.8 21 2.14 i
2 le 58 HOT TUBE SHEE T 1.4 17 1.39 2
10 58 COLD TUBESHEET 4.7 17 0.74 2
10 59 HOT 3PO l'SP 6.2 20 1.44 2
10 61 COLD TUBE SHE E T 3.0 6
2.03 2
10 61 COLD TUBESHEET 3.6 10 2.35 2
10 62 COLD TUBESHEET 2.7 17 1.52 2
10 63 COLD TUBESHEET 2.4 19 3.07 2
10 63 COLD TUBESHEE T 3.5 17 1.55 2
10 64 COLD TUBESHEET 2.2 30 0.70 2
10 64 COLD TUBESHEET 2.8 16 3.66 2
10 65 HOT 3RD TSP 9.4 3S 2.87 2
10 65 COLD TUBESHEET 2.2 43 0.77 2
to 65 COLD TUBESHEET 2.7 17 2.77 2
10 66 HOT 3RD TSP 4.6 52 2.51 2
10 66 HOT 3RD TSP 8.3 28 1.09 2
10 66 COLD TUBESHEET 1.3 22 4.37 2
10 66 COLD TUGESHEET 2.7 4
1.35 2
10 67 COLD TUBESHEET 2.0 28 1.25 2
10 67 COLD TUBESHEET 2.6 10 2.58 2
10 68 COLD TUDESHEET 0.8 23 2.13 2
10 68 COLD TUBESHEET 2.6 16 1.54 2
10 69 COLD TUBESHEET 0.9 49 0.54
Surt1ARY OF CV 1986 EDDY CURRENT INSPECTION KATA 0:19 WED12SD*.Y HARCH 5. 1986 le LISTIt3 OF ALL TUBE FLAWS
=
FOR STEAN GENE ATDR 02 STEAf1 GENERATOR ROW CDLutti LDC FLAW LOCATI0tt FLAW HEIGHT !!HCHESI FLAW SIZE 1%I DEFECT VOLTAGE 2
le 69 COLD TUBESHEET 1.3 18 1.70 2
10 70 COLD TUBESHEET 0.0 39 9.67 2
le 70 COLD TUBESHEET 1.1 30 3.51 2
10 71 COLD TUBESHEET 0.0 36 7.16 2
10 71 COLD TUBESHEET 1.6 9
1.11 2
10 72 COLD TUBESHEET 1.0 to 3.86 2
10 73 COLD TUBESHEET 1.0 23 8.67 2
to 73 COLD TUBE SHEE T 1.9 10 3.70 2
10 74 COLD TUBESHEET 0.8 19 6.61 2
10 74 COLD TUBESHEET 1.9 4
4.63 2
10 75 COLD TUBESHEET 0.0 8
2.32 2
10 75 COLD TUBESHEET 1.1 19 1.33 2
10 76 COLD TUBESHEET 0.7 24 4.89 2
10 76 COLD TUBESHEET 2.1 19 0.81 2
10 77 COLD TUBESHEET 0.8 29 5.56 2
10 78 COLD TUBESHEET 2.5 19 2.10 2
10 79 COLD TUBESHEET 1.4 27 1.81 2
10 80 COLD
)UBESHEET 1.0 19 3.12 2
10 81 COLD TUBESHEET 1.0 30 2.12 2
10 82 COLD TUBESHEET 1.7 22 2.37 2
10 83 COLD TUBESHEET 0.8 41 0.91 2
10 83 COLD TUBESHEET
!.6 31 0.75 2
10 84 COLD TUBE SHEET 1.3 14 2.85 2
10 84 COLD TUBESHEET 2.4 11 2.37 2
10 85 COLD TUBESHEET
!.6 15 1.16 2
10 86 COLD TUBESHEET 0.6 2
10 87 HOT 3RD TSP 7.9 18 1.38 56 2.49 2
10 87 HOT 3RD TSP 10.5 24 1.66 2
10 88 HOT 3RD TSP 10.6 26 2.50 2
10 93 HOT 3RD TSP 15.9 17 1.57 2
6 HOT 3RD TSP 4.9 44 2,07 2
11 14 HOT TUBESHEET I.3 2
2.70 2
11 14 COLD TUE E SHE ET 1.8 10 1.90 2
11 15 CotD TUBESHEET 1.0 4.04 2
11 15 COLD TUBESHEET 2.1 11 4.01 2
11 16 COLD TUBESHEET 2.3 18 3.87 2
17 C010 TUBESHEET 1.7 10 2.73 2
11 18 CotD TUBESHEET 1.5 14 4.88 2
11 19 COLD TUBESHEE T 2.4 17 3.42 2
11 19 COLD TUBESHEET 3.1 10 4.58 2
11 20 COLD TUBESHEET 2.6 24 4.65 2
11 21 COLD TUBESHEET 3.8 15 2.31 2
11 21 COLD TUBESHEET 2.9 13 3.10 2
11 22 COLD TUBESHEET 3.3 6
3.79 2
11 23 COLD TUBE SHEE T 2.5 26 1,61 2
11 23 COLD TUBESHEET 4.1 7
2.67 2
11 24 COLD TUBESHEE T 3.2 11 2.31 2
Il 24 COLD TUBE SHE E T 4.0 1
2.39 2
11 25 COLD TUCESitEET 2.1 14 3.46 2
11 25 C010 TUBESHEET 4.7 5
1.35 2
11 26 COLD TUBESHEET 2.1 24 1,71 2
11 27 COLD TUBE SHE E T 1.8 29 2.50 2
11 27 COLD TUBESHEET 3.5 2
2.37 2
11 26 COLD TUBESHEET 1.9 15 3.32
SUMMARY
OF CY 1936 EDDT CURREHT INSPECTIDH COTA 8:10 WEDIESDAY. itARCH 3,1986 11 LISTII:3 OF ALL TUBE FLAWS FOR STEAM GENE!AfDR 82 STEAM GENERATOR R0W COLUt94 LOC FLAW LOCATION FLAW MEIGHT IIHCHESI FLAW SIZE (%1 DEFfCT WOLTAGE 2
11 28 COLD TUBE SHEET 3.5 33 0.82 2
11 29 COLD TUBESHEET 1.2 42 2.33 2
11 29 C01D TUBESHEET 3.0 30 6.15 2
11 30 COLD TUBESHEET 3.2 31 2.29 2
30 COLD TUBESHEET 2.0 26 4.32 2
31 COLD TubESHEET 2.9 26 4.54 2
32 COLD TUBESHEET
!.7 23 8.14.
2 ~
32 COLD TUBESHEET 2.8 18 4.83 2
11 33 COLD TUBE SHE ET 2.5 31 2.22 2
11 33 COLD TUBESHEET 3.7 12 3.16 2
11 34 COLD TUBESHEET
!.8 29 6.78 2
11 34 COLD TUBESHEET 3.5 16 2.46 2
11 35 COLD TUBESHEET 2.0 23 2.49 2
11 36 COLD TUBESHEET 2.1 24 1.95 2'
11 37 COLD TUBESHEET 0.7 11 f.e s 2
11 37 COLD TUBESHEET 2,2 16 3.75 2
11 38 COLD TUBESHEET 2.1 19 4.70 2
11 39 COLD TUBESHEET 3.9 13
- 1. 7C-2 40 COLD TUBESHEET 4.1 22 1.44 2
11 41 COLD TUBESHEET 2.6 26 3.11 2
11 42 COLD TUBESHEET 3.3 18 2.26 2
11 42 COLD TUBESHEET 4.6 IS 1.39 2
11 44 COLD TUBESHEET 4.2 22 0.68 2
11 44 COLD TUBESHEET 5.5 15 2.80 2
11 45 COLD TUBESHEET 5.5 4.49 2
11 46 COLD TUBESHEET 4.9 19 2.20 2
46 COLD TUBESHEET 5.6 3
4.00 2
11 47 COLD TUBESHEET 4.3 15 2.22 2
11 48 COLD TUBESHEET 4.0 17 3.60 2.
11 49 HOT TUBESHEET 6.3 30 1.08 2
11 49 COLD TUBESHEET 5.4 17 1.13 2
11 50 COLD TUBESHEET 5.6 19 3.41 2
11 50 COLD TUBESHEET 6.3 19 1.00 2
11 51 COLD TUBESHEET 5.3 22 2.19 2
11 52 CotD TUBESHEET 3.8 23 4.57 2
11 52 COLD TUBESHEET 5.0 17 1.63 2
11 53 COLD TUBESHE E T 6.0 24 3.39 2
54 COLD TUBESHEET 6.2 20
.l.85 2
11 55 COLD TUBESHEET 4.5 6
1.93 2
11 56 Cat 0 TUBESHEET 4.1 17 1.50 2
56 COLD TUBESHEET 5.6 9
1.43 2
11 57 HOT TUBESHEET 3.5 8
1.92 2
11 58 COLD TUBESHEET I.6 9
1.44 2
11 59 COLD TUBE SHEET 4.5 23 3.20 2
11 60 HOT TUBESHEET 2.0 17 1.07 2
11 60 COLD TUBESHEET 3.7 9
1.88 2
11 61 COLD TUBE SHEET 3.5 17 3.79 2
11 62 COLD TUBESHEET 3.3 10 2.47 2
11 63 COLD TUBESHEET 2.4 14 3.00 2
63 COLD TUBESHE E T 3.2 8
1.97 2
11 64 COLD TUBESHEET 0.9 18 3.67 2
11 65 COLD TUBESHEET 1.9 20 2.96 2
65 COLD TUBESHEET 3.0 12 3.12 2
11 66 HOT 3RD TSP 4.4 43 2.01
Sutt1ARY OF CY 1986 EDDT CURRENT INSPECTION DATA 0:19 WEDl4ESDAY, MARCH 5. 1986 12 LISTIt.3 0F ALL TUBE FLAWS e
FOR STEAtt GENERATOR 82 STEAN GENERATOR R0W COLUNH LOC FLAW LOCATIDH FLAW HEIGHT IIHCHESI FLAW SIZE IX)
DEFECT VOLTAGE 2
66 COLD TUBESHEET 1.2 22
'2.95 2
11 66 COLD TUBESHEET 2.7 18 0.67 2
11 67 COLD TUBESHEET 1.9 29 3.e4 2
68 COLD TUBESHEET 1.3 29 4.17 2
11 69 COLD TUBESHEET 1.3 31 5.48 2
11 69 COLD TUBESHEET 2.1 9
1.94 2
11 70 COLD TU3ESHEET 0.0 35 5.03 2
70 COLD TUBESHEET 1.0 32 2.80 2
11 71 COLD T*d3ESHE ET 0.2 40 6.28 2
71 COLD
.TU3ESMEET 1.0 31 5.32 2
11 72 COLD TUDESHEET
!.0
'27 7.06 2
11 72 COLD TUBESHEET 1.8 6
3.31 2
11 73 COLD TUBESHEET 0.9 26 8.32 2
11 73 C0tc TUBESHEET
. 2.2 7
4.68 2
11 74 COLD TUBESHEET 1.1 21 5.32 2
11 74 -
COLD,
TUBESHEET 2.0 10 4.88 2
75 CotD ~
TUBESHEET 0.8 32 2.07 2
11 75 COLD TUBESHEET 2.2 19 2.03 2
76 CJ.?
THBESHEET 21 21 3.23 2
77 "Ot h TUBESHEET 2.0 9
1.81 2
11 78 Cr O Tue5 SHEET 0.7 i
2 11 78 f*St TUBESHEET 2.3 41 2.28 20 1.21 2
11 79 J"tD TUBESHEET 0.2 32 4.76 2
11 80
- m TU6ESHEET 1.3.
28 1.30 2
11 80 1...
TUBESHEET 2.5 13 1.56 2
11 81 COLD TUBESHEET 0.8 25 4.60 2
11 81 COLD TUBESHEET 2.4 11 2.10 2
11 82 COLD TUBESHEET 0.8 28 4.54 2
II 82 COLD TUBE SHEET 1.8 15 3.48 2
11 83 COLD TUBESHEET
!.2 19 0.84 2
11 84 COLD TUBESHEET 2.2 7
1.24 2
85 COLD TUBE SHEET 1.2 18 2.87 2
12 E3 HOT TUBESHEET 1.5 7
0.83 2
12 13 HOT TUCESHEET 1.5 16 0.53 2
12 15 COLD TUBESHEET 1.2 23 4.30 2
12 14 COLD TUBESHEET 3.9 18 2.87 2
12 16 COLD TUDESHEET 1.5 16 2.55 2
12 16 COLD TUBESHEET 2.1 22 1.77 2
12 17 COLD TUBESHEET 1.7 19 7.94 2
12 17 COLD TUBESHEET 2.5 32 4.88 2
12 18 COLD TUBESHEET 1.9 25 4.11 2
12 19 COLD TUBESHEET 2.8 21 4.41 2
12 20 COLD TUBESHEET 2.6 27 5.68 2
.12 21 COLD TUBESHEET 2.9 to 6.05 1
2 12 22 COLD TUBESHEET 3.0 18 3.10 2
4, 12 23 COLD TUBESHEET 2.3 15 2.85 2
12 23 COLD TUBESHEET 4.1 23 1.57 2
12; 24 Col 0 TUBESHEET 2.2 4
4.07 2
12 24 COLD
.TUDESHEET 3.9 10 4.86 2
12 25 Cat 0 TUBESHEET 2.9 20 2.00 2
12 25 COLD TUDESHEET 4.8 5
1.37 i
2 12 26 COLD TUBESHEET 2.1 12 1.65 2
12 26 COLD TUBESHEET 2.2 8
4.60 2
12 26 COLD TUBESHEET 2.8 I.5 3.00 l
- =
SLRWARY OF CY 1986 ED0Y CURKENT INSPECTION DATA 0:19 HEDHESD AY, MARCH 5.1986 13 LISTIlia OF ALL TUCE FLAWS FOR STEAN GENERATOR 02 STEAN GENERATOR ROW COLUMH LOC FLAW LOCATIDH FLAW HEIGHT IIHCHESI FLAW SIZE 1%I DEFECT VOLTAGE 2
12 27 COLD TUBESHEET 2.1 16 3.78 2
12 27 COLD TUBESHEET 4.4 8
1.46 2
12 28 COLD TUBESHEET 1.7 29 5.44 2
12 28 COLD TUBESHEET 3.4 12 2.20 2
12 29 COLD TUBESHEET 1.4 9
2.83 2
12 30 COLD TUBESHEET 2.6 24 2.91 2
12 31 COLD TUBESHEET 2.8 22 3.20 2
12 32 COLD TUBESHEET 1.1 33 1.33 2
12 32 COLD TUBESHEET 3.1 13 4.33 2
12 33 COLD TUBESHEET 1.7 33 2.10 2
12 33 COLD TUBESHEET 3.1 11 3.55 2
12 34 COLD TUBESHEET 0.6 20 2.81 2
12 34 COLD TUBESHEET 2.1 32 2.!!
2 12 35 COLD TUBESHEET 1.4 29 1.74 2
12 35 COLD TUBESHEET 2.2 21 1.03 2
12 36 COLD TUBESHEET 2.6 24 2.05 2
12 37 COLD TUBESHEET 2.5 26 4.13 2
12 38 COLD TUBESHEET 2.3 32 3.27 2
12 39 COLD TUBESHEET 2.0 25 3.97 2
12 40 COLD TUBE SHEET 2.5 29 4.31 2
12 40 COLD TUBESHEET 3.8 20.
3.99 2
12 41 COLD TUBESHEET 2.6 31 2.61 2
12 41 COLD TUBESHEET 4.2 20 1.21 2
12 42 COLD TUBESHEET 2.7 30 2.22 2
12 42 COLD TUBESHEET 4.8 17 1.44 2
12 43 COLD TUBESHEET 3.2 32 2.53 2
12 43 COLD TUBESHEET 4.8 15 1.61 2
12 44 COLD TUBESHEET 3.7 24 2.62 2
12 44 COLD TUEESHEET 5.0 to 1.18 2
12 45 COLD TUBESHEET 5.2 9
2.74 2
12 46 COLD TUBESHEET 3.9 17 1.93 2
12 47 COLO TUBLSHEET 4.0 28 1.09 2
12 48 HOT TUBESHEET 3.5 19 1.50 2
12 48 COLD TUBESHEET 5.1 35 1.36 2
12 49 COLD TUBESHEET 3.6 41 1.06 2
12 49 COLD TUBESHEET 7.1 11 0.97 2
12 50 COLD TUBESHEET 3.7 36 1.81 l
2 12 50 COLD TUBESHEET 5.1 26 1.02 l
2 12 51 COLD TUDESHEET 5.0 28 3.47 2
12 52 COLD TUBESHEET 4.0 17 1.91 2
12 53 COLD TUDESHEET 4.6 36 1.03 2
12 53 COLD TUBESHEET 5.8 15 3.32 2
12 54 COLD TUBESHEET 4.6 31 1.00 2
12 54 COLD TUCESHEET 5.9 19 3.85 2
12 55 COLD TUBESHEET 4.8 21 2.40 2
12 55 COLD T UDESHEET 8.0 15 0.69 2
12 56 COLD TUBESHEET 4.0 21 3.21 2
12' 56 COLD TUBESHEET 5.9 19 0.94 2
12 57 COLD TUBESHEET 1.3 34 0.98 2
12 57 COLD TUBE SHE E T 5.1 21 2.31 2
12 58 COLD TUBESHEET 4.4 21 2.50 2
12 58 COID TUBESHEET 5.2 17 1.79 2
12 59 COLD TUBESHEET 3.2 26 2.29 2
12 59 COLD TUBESHE ET 4.5 17 1.92
.l SUPMA0Y OF CY 1986 ED0Y CURRENT INSPECTION DATA 0:19 WEDNESDAY MARCH 5. 1986 14 LISTIlt3 0F ALL TUBE FLAWS
'FOR STEAN GENE 2ATOR 82 STEAM GENERATOR ROW COLIJPN LOC FLAW LOCATION FLAW HEIGHT IIHCHESI FLAW SIZE 1%I DEFECT VOLTAGE 2
12 60 COLD TUBESHEET 3.3 to 1.51 2
12 60 COLD TUBESHEET 4.0 17 1.02 2
12 61 COLD TUBESHEET 1.9 25 0.77 2
12 61 COLD TUBESHEET 3.0 7
0.98 2
12 62 COLD TUBESHEET 2.9 37 0.65 2
12 62 COLD TUBESHEET 3.8 12 1.44 2
12 63 COLD TUBESHEET 1.6 23 1.20 2
12 63 COLD TUBESHEET 2.4 15 1.08 2
12 64 COLD TUBESHEET 2.4 22 2.48 2
12 64 COLD TUBESHEET 3.3 21 1.10 2
12 65 COLD TUEE SHEET 1.7 25 2.92 2
12 65 COLD TUBESHEET 3.2 26 1.55 2
12 66 COLD TUBESHEET 0.2 39 1.44 2
12 66 COLD TUBESHEET 3.0 30 0.80 2
12 67 COLD TUBESHEET 0.2 40 4.17 2
12 67 COLD TUBESHEET 1.9 40 1.28 2
12 68 COLD TUBE SHEET 0.1 41 6.61 2
12 68 COLD TUBESHEET 4.8 3
1.60 2
12 69 COLD TUBESHEET 0.2 20 5.22 2
12 69 COLD TUBESHEET 1.9 17 3.14 2
12 70 COLD TUBESHEET 0.9 29 4.22 2
12 70 COLD TUBESHEET 2.2 17 3.60 2
12 71 HOT TUBESHEET 3.6 36 0.88 2
12 71 HOT TUBESHEET 4.6 6
0.73 2
12 71 COLD TUBESHEET 0.0 41
- 3. 36 2
12 71 COLD TUBESHEEf 2.4 IS 3.00 2
12 72 COLD TUBESHEET 1.6 34 5.95 2
12 72 COLD TUBESHEET 2.0 13 4.49 2
12 73 COLD TUBESHEET 1.0 29 6.03 2
12 73 COLD TUBESHEET 1.9 9
4.29 2
12 74 COLD TUBESHEET 0.8 32 7.10 l
2 12 74 COLD TUBESHEET
!.9 24 3.87 2
12 75 COLD TUBESHEET 4.8 37 3.02 2
12 75 COLD TUBESHEET 1.9 18 1.85 I
2 12 76 COLD TUBESHEET 1.0 27 1.13 2
12 77 COLD TUBESHEET 1.1 13 1.28 2
12 78 COLO 10BESHEET 0.9 32 5.18 2
12 78 COLD TUBESHEET 1.8 21 2.74 2
12 79 COLD TUBESHEET 0.7 32 6.49 2
12 79 COLD TUBESHEET 2.0 21 1.51 2
12 80 COLD TUBESHEET 0.7 25 2.92 2
12 80 COLD TUBESHEET 1.9 6
2.58 2
12 81 COLD TUBESHEET 0.8 38 3.01 2
12 82 COLD TUBESHEET 1.2 19 2.19 2
12 83 COLD TUBE SHEET 1.3 31 3.24 2
12 84 HOT 3RD TSP 4.5 59 0.69 2
12 84 COLD TUBESHEET 1.1 26 2.72 2
12 85 HOT TUBESHEET 4.1 3
2.30 2
12 85 COLD TUBESHEET 1.2 16 1.34 2
12 94 HOT 3R0 TSP 17.3 17 1.56 2
13 14 HOT TUBE SHEET 0.8 5
3.15 2
13 15 COLD TUBESHEET 1.2 20 3.08 2
13 15 COLD TUBESHEET 2.0 1
1.80 2
13 16 COLD TUBESHEET 1.5 17 5.97
SurttARY OF CY 1986 EDDY CLRRENT INSPECT!0H DATA 0:10 WEDt'ISDAY MARCH 5, 1986 15 LISTING OF ALL TUCE FLAWS FOR STEAtt GEHECATOR 82 STEAM GENERATOR RDW COLUNH LOC FLAW LOCATIDH FLAW HEIGHT (IHCHES)
FLAW SIZE (%I DEFECT VOLTAGE 2
13 17 CCLD TUBESHEET 1.5 20 2.72 2
13 17 COLD TUBESHEET 2.7 13 5.31 2
13 18 COLD TUBESHEET 0.8 27 2.33 2
13 18 COLD TUBESHEET 1.8 18 2.67 2
13 19 COLD TUBESHEET 3.1 23 6.52 2
13 20 COLD TUBESHEET 2.9 21 5.04 2
13 21 COLD TUBESHEET 3.0 26 4.73 2
13-22 COLD TUBESHEET 2.9 21 3.46 2
13 22 COLD TUBESHEET 3.5 19 2.27 2
13 22 COLD TUBESHEET 4.2 15 1.07 2
13 23 COLD TUBESHEET 2.2 7
3.41 2
13 23 COLD TUBESHEET 3.0 35 2.T4 2
13 24 COLD TUBESHEET 2.1 6
5.57 2
13 24 COLD TUBESHEET 3.8 4
3.71 2
13 25 COLD 2HD TSP 35.3 10 1.07 2
13 25 COLD TUBESHEET 2.3 15 8.72 2
13 25 COLD TUBESHEET 4.0 18 2.63 2
13 26 COLD TUBESHEET 2.3 15 3.99 2
13 26 COLD TUBESHEET 3.9 9
2.19 2
13 27 COLD TUBESHEET 2.8 30 1.84 2
13 27 COLD TUBESHEET 3.7 13 1,43 2
13 28 HOT TUBE SHEET 2.8 22 1.73 2
13 28 COLD TUBESHEET 2.5 25 2.53 2
13 29 COLD TUBESHEET 2.8 23 2.05 2
13 30 COLD TUBESHEET 3.7 19 0.69 2
13 31 COLD TUBESHEET 0.9 48 1.67 2
13 31 COLD TUBESHEET 3.9 18 1.32 2
13 32 COLD TUBESHEET 1.6 24 5.16 2
13 32 COLD TUBESHEET 3.2 21 3.38 2
13 33 COLD TUBESHEET 3.1 16 4.62
'2 13 34 COLD TUBESHEET 1.2 30 2.84 2
13 34 COLD TUBESHEET 1.8 32 0.59 2
13 35 COLD TUBESHEET 2.4 40 1.94 2
13 36 COLD TUBESHEET 3.0 5
4.18 2
13 37 COLD TUBESHEET
!.7 42 1.10 2
13 37 COLD TUBESHEET 3.1 13 2.70 2
13 38 COLD TUBESHEET 2.1 41 1.36 2
13 38 COLD TUBESHEET 3.8 18 0.67 2
13 39 COLD TUDESHEET 2.0 23 S.87 2
13 40 COLD TUBESHEET 2.0 31 1.42 2
13 40 0010 TUBESHEET 2.4 24 4.59 2
13 41 COLD TUBESHEET 2.5 26 5.47 2
13 41 COLD TUCESHEET 3.8 13 3.58 2
13 42 CotD TUBESHEET 2.4 32 3.03 2
13 42 COLD TUBESHEET 2.8 53 0.77 2
13 43 COLD TUBESHEET 3.0 17 2.49 2
13 44 HOT TUBESHEET I.8 95 1.30 2
13 44 COLD TUBESHEET 1.4 23 1.19 2
13 44 COLD TUBESHEET 3.1 22 1.19 2
13 45 COLD TUBESHEET 5.1 12 1.73 2
13 46 COLD TUBESHEET 3.4 36 1.06 2
13 46 COLD TUBESHEET 5.2 30 1.06 2
13 47 COLD TUBESHEET 2.9 42 0.80 2
13 47 COLD TUBESHEET 5.0 19 1.11
Sut91 ART OF CY 1986 ED0Y CURRENT INSPECTION CATA 0:19 WEDHESDAY. HARCH 5. 1986 16 LISTING OF ALL TUEE FLAMS FOR STEAM GENE!ATDR 82 STEAM GENERATOR ROW COLUNH LOC FLAW LOCATIDH FLAW HEIGHT IIHCHES)
FLAW SIZE 1%)
DEFECT VOLTAGE 2
13 48 COLD TUBESHEET 3.0 23 1.89 2
13 48 COLD TUBESHEET 4.9 21 2.75 l
2 13 49 COLD TUBESHEET 4.1 41 0.47 2
13 49 COLD TUBESHEET 4.8 19 2.14 2
13 50 COLD TUBESHEET 4.4 25 1.19 2
13 50 COLD TUBESHEET 5.7 20 1.50 2
13 51 HOT TUBESHEET 8.2 15 1.28 2
13 51 COLD TUBESHEET 3.9 28 0.57 2
13 52 COLD TUBESHEET 0.5 19 1.08 j
2 13 53 COLD TUBESHEET 4.2 11 1.84 2
13 55 COLD TUBESHEET 5.3 25 2.47 2
13 -
56 COLD TUBESHEET 3.4 17 2.96 2
13 56 COLD TUBESHEET 5.6 17 1.81 2
13 57 COLD TUBESHEET 5.1 9
1.92 2
13 58 COLD TUBESHEET 2.0 20 2.35 2
13 58 COLD TUBESHEET 4.5 15 2.10 2
13 59 COLD TUBESHEET 2.9 18 1.01 2
13 60 COLD TUBESHEET 2.6 23 1.81 2
13 61 COLD TUBESHEET 2.4 16 2.22 2
13 61 COLD TUBESHEET 3.8 2
2.35 2
13 62 COLD TUBE SHE ET 2.2 31 2.45 2
13 62 COLD TUBESHEET 3.4 19 0.20 2
13 63 COLD TUBESHEET 2.0 16 3.54 2
13 64 COLD TUBE SHEET 1.8 26 5.11 2
13 64 COLD TUBESHEET 3.0 3
1.83 2
13 65 COLD TUBESHEET 1.5 14 4.07 2
13 66 COLD TUBESHEET 2.4 20 2.27 2
13 67 COLD TUBESHEET 1.4 15 2.45 2
13 68 COLD TUBESHEET 0.9 32 1.89 2
13 68 COLD TUBESHEET 2.4 7
2.24 2
13 69 COLD TUBESHEET I.4 44 0.99 4
2 13 69 COLD TUBE SHE E T 3.1 10 1.19 2
13 70 COLD TUBESHEET 0.9 29 4.22 2
13 70 COLD TUBESHEET 1.0 39 2.57 2
13 70 COLD TUBESHEET 2.5 2
3.37 2
13 71 COLO TUBESHEET 1.2 42 3.14 2
13 72 COLD TUBESHEET 0.9 29 5.27 2
13 72 COLD TUBESHEET 2.4 15 1.34 2
13 73 COLD TUBESHEET 1.0 33 6.52 2
13 73 COLD TUBESHEET 2.2 19 1.39 2
13 74 HOT TUBESHEET 1.1 4
2.05 2
13 74 COLD TUBESHEET 0.9 34 8.69 2
13 74 COLD TUBESHEET 2.0 19 2.88 2
13 75 COLD TUBESHEET 1.3 26 3.07 2
13 76 COLD TU6ESHEET 0.8 31 1.86 2
13 77 COLD TUBESHEET 0.5 23 1.49 2
13 78 COLD TUBESHEET 0.7 29 4.22 2
13 78 COLO TUBESHEET 2.1 14 3.67 2
13 79 COLD TUBESHEET 0.9 42 3.69 2
13 79 COLD TUDESHEET 1.9 24 2.36 2
13 80 CotD TUBESHEET 1.0 26 2.8S 2
13 80 COLD TUBESHEET 2.1 15 1.47 2
13 82 COLO TUBESHEET 1.6 10 2.96 2
13 83 COLD TUBESHEET
!.0 25 2.92
MM Sutt1ARY OF CY 1986 ED0Y CURRENT INSPECTION DATA 0:10 WEDHESDAY, itARCH 5.1986 17 LISTING OF ALL TUBE FLAWS FOR STEAN GEHERATOR 02 STEAN GEHERATDR ROW COLUNH LOC FLAW LOCATI0t4 FLAW HEIGHT IIHCHES)
FLAW SIZE 1%)
DEFECT VOLTAGE l
l 2
13 83 COLD TUBESHEET 1.6 22 2.09 2
13 84 COLD TUBESHEET 1.6 13 3.30 2
13 85 COLD TUBESHEET 1.3 21 3.10 2
13 86 HOT 3RD TSP 3.5 18 1.08 2
13 94 COLD 2HD TSP 29.6 4
2.15 2
14 4
HOT TUBESHEET 6.0 14 1.11 2
14 5
COLD TUBE SHE ET 26.1 4
1.71 2
14 14 COLD TUBESHEET 1.4 7
1.32 2
14 15 COLD TUDESHEET 4
3.25 2
14 16 COLD TUBESHEET 1.5 21 3.47 1
2 14 17 COLD TUBESHEET 1.6 19 2.92 l
2 14 17 COLD TUBESHEET 2.7 18 3.41 2
14 18 COLD TUBESHEET 1.5 33 3.33 2
14 18 COLD TUBESHEET 2.7 3
1.44 2
14 19 COLD TUBESHEET 3.1 28 3.20 2
14 19 COLD TUBESHEET 3.7 18 2.66 l
2 14 20 COLD TUBESHEET 2.6 22 4.46 l
l 2
14 20 COLD TUBESHEET 3.7 15 1.98 2
14 21 COLD TUBESHEET 2.9 22 4.50 l
2 14 21 COLD TUBESHEET 3.9 15 2.91 l
l 2
14 22 COLD TUBESHEET 3.4 23 4.99 i
2 14 23 COLD TUBESHEET 2.2 12 2.07 i
2 14 23 COLD TUBESHEET 3.8 24 1.94 l
l 2
14 24 COLD TUBESHEET 3.1 13 4.40 l
2 14 25 COLD TUBESHEET 3.0 20 5.23 l
2 14 25 COLD TUBESHEET 4.7 9
1.46 2
14 26 COLD TUBESHEET 2.0 32 1.89 2
14 26 COLD TUBESHEET 2.9 29 3.96 l
2 14 27 COLD TUBESHEET 2.7 25 4.!!
2 14 28 COLD TUBESHEET 2.6 26 5.65 2
14 28 COLD TUBESHEET 3.8 16 1.97 2
14 29 COLD TUBESHEET 2.4 40 4.86 2
14 29 COLD TUBESHEET 3.7 22 0.79 2
14 30 COLD TUBESHEET 1.2 25 1.08 2
14 30 COLD TUBESHEET 2.9 22 2.68 2
14 31 COLD TUBESHEET 1.8 38 8.08 2
14 31 COLD TUBESHEET 3.9 18 1.03 2
14 32 COLD TUBESHEET 2.0 26 3.17 2
14 32 COLD TUBESHEET 3.7 21 1.09 2
14 33 COLD TUBESHEET 1.3 12 2.87 2
14 33 COLD TUBESHEET 3.7 17 1.13 2
14 34 HOT TUBESHEET
-3.8 11 0.74 2
14 34 COLD TUBESHEET 1.9 25 2.61 2
14 34 COLD TUBESHEET 2.7 25 4.68 2
14 35 COLD TUBESHEET
!.0 41 1.37 2
14 35 COLD TueESHEET 2.6 17 2.63 2
14 36 COLD TUBESHEET
!.5 29 2.76 2
14 36 COLD TUBESHEET 2.9 26 3.97 2
14 37 COLD TUDESHEET 2.3 24 3.69 l
2 14 37 COLD TUDESHEET 3.1 17 5.21 l
2 14 3S COLD TUBESHEET 1.7 23 2.64 2
14 39 COLD TUDESHEET 2.1 19 2.10 l
2 14 39 COLD TUBESHEET 3.4 9
2.37 2
14 40 COLD TUBESHEET
!.9 32 3.22 l
l
SUtt1 ART OF CV IT86 ED0Y CURRENT INSPECTION DATA 0:19 WEDHESDAY,flARCH 5, 1986 18 LISTIC3 OF ALL TUBE FLAWS FDR STEAN GENERATOR 82 STEAN GENERATDR RDW COLUNH LOC FLAW LDCATION FLAS AEIGHT IIUCHESI FLAW SIZE t%)
DEFECT VOLTAGE 2
14 41 COLD TUBESHEET 2.1 30 3.05 2
14 41 COLD TUBESHEET 3.7 12 1.69 2
14 42 COLD TUBESHEET 2.6 34 4.41 2
14 43 COLD' TUBESHEET 2.5 32
'4.22 2
14 44 COLD TUBESHEET 2.6 21 3.67 2
14 44 COLD TUBESHEET 3.1 22 1.33 2
14 45 COLD TUBESHEET 3.1 16 1.85 2
14 46 COLD TUBESHEET 2.8 21 2.42 2
14 47 COLD TUBESHEET 3.0 29 3.48 2
14 47 COLD TUBESHEET 4.2 16 0.88 2
14 48 COLD TUBESHEET 2.2 32 1.22 2
14 48 COLD TueESHEET 4.8 26 1.10 2
14 48 COLD TUBESHEET 8.7 1
1.24 1
2 14 49 COLD TUBESHEET 2.3 28 2.69 2
14 49 COLD TUBESHEET 4.7 22 1.21 2
14 50 HOT TUBESHEET 10.2 22 0.78 2
14 50 HOT TUBESHEET 10.6 9
1.78 1
2 14 50 COLD TUBESHEET 2.5 29 1.75 2
14 50 COLD TUBESHEET 3.0 18 1.23 2
14 51 COLD TUBESHEET 2.2 27 1.14 2
14 51 COLD TUBESHEET 3.3 21 1.60 2
14 51 COLD TUBESHEET 5.2 15 1.07 2
14 52 COLD TUBESHEET 2.8 8
1.20 2
14 53 COLD TUBESHEET 3.1 24 1.84 2
14 53 COLD TUBESHEET 4.2 17 1.80 2
14 54 COLD TUBESHEE T 3.0 44 0.46 2
14 54 COLD TUBESHEET 4.6 17 1.02 2
14 55 COLD TUBESHEET 3.3 40 0.71 2
14 55 COLD TUBESHEET 5.1 18 1.60 2
14 56 COLD TUBESHEET 3.7 21 1.25 2
14 57 COLD TUBESHEET 2.9 25 2.24 2
14 57 COLD TUBESHEET 4.8 22 2.14 2
14 58 COLD TUBESHEET 4.1 5
3.33 2
14 59 COLD TUBESHEET 2.0 23 2.89 2
14 59 COLD TUBESHEET 3.7 2
3.51 2
14 60 COLD TUBESHEET
!.6 44 1.18 2
14 60 COLD TUBESHEET 2.3 24 3.31 2
14 60 COLD TUBESHEET 3.9 14 4.14 2
14 61 COLD TUBESHEET 0.5 16 2.54 2
14 61 COLD TUBESHEET 2.2 17 2.71 2
14 62 COLD TUBESHEET 1.8 30 1.62 2
14 62 COLD TUBESHEET 3.2 15 2.41 2
14 63 COLD TUBESHEET 1.5 30 4.44 2
14 63 COLD TUBESHEET 2.3 18 0.54 2
14 64 COLD TUBESHEET 1.7 23 4.23 2
14 64 COLD TUBESHEET 3.4 17 3.28 2
14 65 COLD TUBESHEET 1.6 22
- 4.78 -
2 14 65 COLD TUBESHEET 2.6 14 1.82 2
14 66 COLD TUBESHEET 1.4 16 4.61 2
14 66 COLD TUBESHEET 2.5 16 2.75 2
'14 67 COLD TUDESHEET 0.9 27 1.30 2
14 67 COLD TUBESHEET 2.3 23 2.65 2
14 68 COLD TUDESHEET 1.1 34 2.88 2
14 68 COLD TUBESHEET 2.3 28 3.59
SUPT 1 ART OF CY 1986 EDDY CURRENT INSPECTION CATA 0:19 WEDHESDAY. MARCH 5. 1986 19 L15 tit:G DF ALL TUBE FLAWS FOR STEAn GENEIATDR 02 STEAM GENERATOR 90W COLLR94 LOC FLAW LOCATION FLAW HEIGHT IINCHESI FLAW SIZE 1%)
DEFECT VOLTAGE 2
14 69 COLD TUBESHEET 1.1 32 5.47 2
14 69 COLD TUBESHEET 1.8 17 3.44 2
14 70 COLD TUBESHEET 1.1 37 3.64 2
14 70 COLD TUBESHEET 2.2 22 1.32 2
14 72 COLD TUBESHEET 1.1 28 5.77 2
14 72 Col?
TUBE SHEET 2.7 13 1.12 2
14 73 COLD TUBESHEET 0.9 29 4.74 2
14 73 COLD TUBESHEET 2.4 6
2.14 2
14 74 COLD TUBESHEET 0.8 27 7.09 2
14 74 COLD TUBESHEET 2.5 13 2.89 2
14 75 COLD TUBESHEET 1.1 28 5.72 r
2 14 75 COLD TUBESHEET 2.5 13 3.44 2
14 76 COLD TUBE SHE ET 1.1 31 4.51 2
14 76 COLD TUBESHEET 2.4 13 2.43 2
14 77 COLD TUBESHEET 0.8 41 3.91 2
14 78 COLD TUBESHEET 1.9 21 1.00 2
14 79 COLD TUBESHEET 0.9 37 3.70 2
14 79 COLD TUBE SHEE T 1.7 15 2.47 2
14 80 COLD TUBESHEET 1.2 32 1.47 2
14 80 COLD TUBESHEET 1.7 19 1.81 2
14 81 COLD TUBESHEET 1.6 23 1.50 l
2 14 81 COLD TUBESHEET 1.9 17 1.71 2
14 82 HOT 2HD TSP 12.9 7
2.48 I.
2 14 82 COLD TUBESHEET 1.0 12 1.24 l
2 14 82 COLD TUBESHEET 1.8 13 4.92 2
14 83 COLD TUBESHEET 0.6 32 3.05 2
14 83 COLD TUBESHEET 1.7 28 3.88 I
2 14 84 HOT TUBESHEET
!.6 8
0.74 2
14 84 COLD TUBESHEET 3.5 15 1.84 j
2 14 85 HOT 3RD TSP 4.5 30 1.70 1
.2 14 85 HOT 3RD TSP 6.2 40 3.40 2
14 86 HOT 3RD TSP 5.8 19 1.97 i
2 15 10 HOT TUBESHEET 4.3 9
1.0S 2
15 13 COLD TUBESHEET 1.2 15 1.51 2
15 14 COLD TUBESHEET 2.4 2
0.62 2
15 15 COLD TUBESHEET
!.2 7
2.10 2
15 16 COLD TUBESHEET 2.1 9
2.60 i
2 15 17 COLD TUBESHEET 2.0 12 4.55 2
15 18 COLO TUBESHEET 1.5 18 3.12 2
15 19 COLD TUBESHEET 3.2 19 1.76 2
15 20 COLD TUBESHEET 2.7 23 3.50 2
15 20 COLD TUBESHEET 3.8 7
2.35
~
2 15 21 COLO TUBESHEET 2.9 20 3.07 2
15 22 COLD TUBESHEET 4.1 14 3.56 2
15 23 COLD TUBESHEET 3.8 31 0.97 2
15 23 COLD TUBESHEET 4.2 22 1.11 2
15 24 COLD TUBESHEET 3.0 8
3.31 2
15 24 COLD TUBESHEET 4.4 1
1.26 2
15 25 COLD TUBESHEET 2.1 13 1.71 2
15 25 COLD TUBESHEET
' 3.1 16 4.18 2
15 25 COLD TUBESHEET 4.5 6
0.83 2
15 26 COLD TUDESHEET 2.0 27 1.20 2
15 26 COLD TUBESHEE T 4.4 11 0.94 2
15 27 COLD TUBESHEET 2.7 29 3.57
SLR91ARY OF CT 1986 EDDY CtRRENT INSPECTIOH DATA 0:10 llEDHESDATo MARCH 5.1986 20 LISTIK3 0F ALL TUBE FLAWS FOR STEAH GENERATOR 82 STEAM GENERATOR ROW COLUrti.
LOC FLAW LOCATION FLAW HEIGHT IIHtHESI FLAN SIZE (%)
DEFECT VOLTAGE 2
15 28 COLD TUBESHEET 2.6 31 0.95 2
15 28 COLD TUBESHEET 2.9 16 3.38 2
15 29 COLD TUBESHEET 2.1 6
4.42 2
15 29 COLD TUBESHEET 3.4 9
1.87 2
15 30 COLD TUBESHEET 3.3 22 2.59 2
15 31 COLD TUBESHEET
. l.7 20 2.25 2
15 31 COLD TUBESHEET 3.5 21 3.20 2
15 32 COLD TUBESHEET 1.7 34 0.93 2
IS 32 COLD TUBESHEF.T 2.1 10 2.49 2
15 33 COLD TUBESHEET 0.5 13 2.57 2
IS 33 COLD TUBESHEET 1.2 16 3,03 2
15 33 COLD TUBESHEET 2.1 15 2.21 2
15 34 COLD TUBESHEET 2.0 29 3.15 2
15 35 COLD TUBESHEET 0.5 17 1.73 2'
15 35 COLD TUBESHEET 2.4 26 7.01 2
15 36 COLD TUBESHEET 0.5 18 2.35 2
15 37 COLD TUBESHEET 1.5 34 1.71 2
15 37 COLD TUBESHEET 3.1 10 2.94 2
15 38 HOT TUBESHEET 6.6 17 3.04 2
15 38 COLD TUBESHEET 1.5 29 1.60 2
15 38 COLD TUBESHEET 2.4 15 1.57 2
15 39 COLD TUBESHEET 2.0 19 2.82 2
15 40 COLD TUBESHEET 1.8 24 2.72 2
15 41 COLD TUBESHEET 1.9 29 1.44 2
15 41 COLD TUBE SHE E T 3.4 16 3.11 2
15 42 COLD TUBESHEET 2.4 16 2.80 2
15 43 COLD TUBESHEET 2.4 23 2.81 2
15 44 COLD TUBESHEET 2.3 22 3.42 2
15 44 COLD TUBESHEET 2.3 24 3.01 2-15 45 COLD TUBESHEET 2.5 9
2.89 l
2 15 45 COLD TUBESHEET 3.3 5
1.97 2
15 46 COLD TUBESHEET 2.6 18 3.31 2
15 46 COLD TUBESHEET 4.1 6
1.47 2
15 47 HOT TUBESHEET 8.5 11 3.05 2
15 47 COLD TUBESHEET 2.6 24 3.41 1
2 15 48 COLD TUBESHEET 2.4 39 3.58 2
15 48 COLD TUBESHEET 3.8 20 2.95 2
15 49 COLD TUBESHEET 2.1 27 3.67 2
15 49 COLD TUBESHEET 3.8 18 1.78 2
15 50 HOT TUBESHEET 6.5 3
1.64 2
15 50 COLD TULESHEET 2.4 22 2.77 2
15 51 HOT TUEESHEET 12.8 25 2.41 2
15 51 COLD TUBESHEET 2.5 24 0.66 15 51 COLD TUBESHEET 4.1 7
1.34 2
15 52 COLD TUBESHEET 3.0 31 0.81 2
15 53 COLD TUBESHEET 2.7 28 0.74
'2 15 53 CotD TUBESHEET 4.8 10 1.14 2
15 54 COLD TUBESHEET 2.2 36 0.58 2
15 54 COLD TUDESHEET 4.7 13 0.81 2
15 55 COLD TUBESHEET 4.0 19 0.96 2
15 56 COLD TUDESHEET 2.5 16 1.09 2
15 57 COLD TUBESHEET 2.2 17 1.90 2
15 58 HOT 3RD TSP 0.9 41 1.36 2
15 58 COLD TUBESHEET 0.5 4
2.48
SuretART OF CT 1986 EDDT CtRRENT INSPECTIDH CATA 0:19 WED8ESOAY. ItARCH 5,1986 21 LISTIl8G OF ALL TUBE FLAWS E
FOR STEAtt GElE;ATOR 02 STEAtt GENERATOR ROW CottR94 LOC FLAW LOCATI0tl FLAW HEIGHT IIt8CHESI FLAW SIZE (%)
DEFECT VOLTAGE 2
15 59 COLD TUBESHEET 1.8 29 1.27 2
15 59 COLD TUBESHEET 3.6 12 1.3I 2
15 60 COLD TUBESHEET 1.9 23 2.15 I
2 15 60 COLD TUBESHEET 3.7 17 0.73 2
15 61 HOT TUBESHEET 5.3 Il 1.68 2
15 61 COLD TUBESHEET 0.4 31 1.03 2
15 61 COLD TUBESHEET 3.6 13 1.08 2
15 62 COLD TUBESHEET
!.7 22 3.78 2
15 62 COLD TUBESHEET 2.8 to 1.42 2
15 63 COLD TUBESHEET 1.5 17 2.9C 2
15 63 COLD TUBESHEET 3.1 11 3.29 2
15 64 COLD TUBESHEET 1.4 18 2.46 2
15 64 COLD TUBESHEET 2.3 12 1,59 2
15 65 COLD TUBESHEET 1.3 28 1.86 2
15 65 COLD TUBESHEET 2.8 12 2.34 2
15 66 COLD TUBESHEET 1.2 12 5.83 2
15 67 COLD TUBESHEET 1.2 2
15 67 COLD TUBESHEET 2.3
'20 5.80 3
3.35 2
15 68 HOT TUBESHEET 1.3 24 4.55 2
15 68 HOT TUBESHEET 2.4 15 1.99 2
15 69 COLD TUBESHEET 1.2 22 4.78 2
15 69 COLD TUBESHEET 2.3 14 3.25 2
15 70 COLD TUBESHEET 1.2 25 4.63 2
15 70 COLD TUBESHEET 1.9 19 3.23 2
15 71 COLD TUBESHEET 2.1 26 2.18 2
15 72 COLD TUBESHEET 1.2 18 1.89 2
15 72 COLD TUBESHEET 2.4 5
1.54 2
15 73 COLD TUBESHEET 4.0 16 3.73 2
15 73 COLD TUBESHEET 2.5 3
1.55 2
15 74 COLD TUBESHEET 2.2 20 1.12 2
IS 75 CotD TUBESHEET 1.0 28 2.78 2
15 75 COLD TUBESHEET 2.6 17 1.24 2
15 76 COLD TUBESHEET 1.0 23 5.25 2
15 77 COLD TUBESHEET 0.7 31 1.46 2
15 78 COLD TUBESHEET 0.5 35 5.92 2
15 78 COLD TUBESHEET 2.1 17 '
l.68 2
15 79 COLD TUBESHEET 1.2 25 1.50 2
IS 79 COLD TUBESHEET
!.8 12 2.20 2
15 81 COLD TUBESHEET 1.4 17 1.00 2
15 82 COLD TUBESHEET'
!.6 12 2.09 2
15 83 COLD 10BESHEET 3.5 7
3.01 2
16 16 COLD TUDESHEET I.1 17 2.16 2
16 17 COLD TUBESHEET 1.8 7
4.51 2
16 IS COLD TUBESHEET I.5 2
3.63 2
16 19 COLD TUBESHEET 2.6 2
4.79 2
16 20 COLD TUBESHEET 2.8 12 2.17 2
16 21 COLD TUBESHEET 1.5 10 1,91 2
16 21 COLD TUBESHEET 2.3 13 2.02 2
16 22 COLD TUBESHEET 2.3 26 1.52 2
16 22 COLD TUBESHEET 3.9 8
2.81 2
16 23 COLD TUBESHEET 1.9 22 2.06 2
16 23 COLD TUBESHEET 4.1 3.26 2
16 24 COLD TUBESHEET 3.8 4
2.25 2
16 25 COLD TUBESHEET 2.8 8
1.94
SUt9 TART OF CT 1986 EDOT CURRENT INSPECTION CATA 0:19 WEDt3SDAT, MARCH 5, 1986 22-LISTIt;5 0F ALL TUBE FLAWS e
FDR STEAM GERSCATOR 62 STEAM GENERATOR ROW COLUt94 LOC FLAN LOCATION FLAW HEIGHT IIHCHESI FLAW SIZE EX)
DEFECT VOLTAGE 2
16 25 COLD TUBE 5HEET 4.3 9
1.32 2
16 26 COLD TUBESHEET 1.9 27 0.94 2
16 26 COLD TUBESHEET 2.7 13 1.36 2
16 26 COLD TUBESHEET 3.6 13 2.28 2
16 27 COLD TUBESHEET 3.1 3
2.44 2
16 28 COLD TUBESHEET 3.1 22 2.71 2
16 29 COLD TUBESHEET 2.2 2
4.62 2
16 29 COLD TUBESHEET 3.5 8
2.42 2
16 30 COLD TUBESHEET 2.4 20 5.21 I
2 16 31 COLD TUBESHEET 3.3 26 0.89 I
2 16 32 COLD TUBESHEET 2.0 19 2.94 2
16 32 COLD TUBESHEET 2.9 12 I.70 2
16 33 HOT TUBESHEET 1.8 15 1.29 2
16 33 COLD TUBESHEET 0.5 14 2.53 i
2 16 33 COLD TUBESHEET 2.9 13 4.29 li 2
16 34 COLD TUBESHEET 1.9 29 2.00 2
16 34 COLD TUBESHEET 2.7 15 4.45 1
2 16 35 COLD TUBESHEET 1.5 27 0.98 2
16 36 COLD TUBESHEET 3.3 15 0.94 1
2 16 37 COLD TUBESHEET 2.9 16 3.04 2
16 38 COLD TUCESHEET 0.5 17 2.31 2
16 38 COLD TUBESHEET 3.2 11 4.53 l
2 16 39 COLD TUBESHEET 1.5 17 3.42 2
16 39 COLD TUBESHEET 3.1 19 2.54 2
16 40 COLD TUBESHEET 2.4 21 2.94 2
16 41 COLD TUBESHEET 2.0 16 2.92 2
16 42 COLD TUBESHEET 3.4 14 2.15 2
16 43 HOT TUBESHEET 8.5 23.
3.64 2
16 43 COLD TUBESHEET 2.5 21 4.20 2
16 44 COLD TUBESHEET 2.3 17 4.67 l
2 16 44 COLD TUBE 5HEET 3.6 5
1.79 2
16 45 COLD TUBESHEET 2.4 12 3.60 I
2 16 46 COLD TUBESHEET 2.8 22 2.02 2
16 47 COLD TUBESHEET 2.2 16 2.50 2
16 48-COLD TUBESHEET 2.3 24 3.27 l
2 16 49 COLD TUBESHEET 2.1 18 3.19 j
2 16 49 COLD TUBESHEET 4.3 19 0.88 2
16 51 COLD TUBESHEET 2.0 19 1.62 2
16 52 COLD' TUBESHEET
!.3 18 1.05 2
16 52 COLD TUBESHEET 2.3 14 1.70 2
16 54 HOT TUBE SHEE T 7.8 40 4.77 2
16 54 COLD TUBESHEET 2.4 21 0.49 2
I6 56 HOT TUEESHEET 7.5 29 6.80 2
16 58 COLD TUBESHEET 1.7 14 1.52 2
16 59 COLD TUCESHEET 1.9 15 1.32 2
16 60 COLD TUBESHEET 1.5 27 1.22 2
16 60 COLD TUBE SHE E T 3.2 20 1.89 2
16 61 HOT TUBESHEET 5.4 5
4.60 2
16 61 COLD TUEESHEET 0.5 18 1.66 2
16 62 COLD TUBESHEET 1.3 21 2.08 2
16 62 COLD TUDESHEET 2.7 15 1.57 2
16 63 COLD TUBE!HEET 2.7 14 2.63 3
2 16 64 HOT 3RD TSP 5.0 30 1.99 2
16 64 COLD TUBESHEET 1.1 15 1.94 1
)
t
SLRMART OF CT 1986 EDOV CURRENT INSPECTION C:ATA 0:19 HEDtlESDAT, t1 ARCH 5.1986 23 LISTII:3 0F LLL TUBE FLAWS FOR STEAtt GENE 2ATOR C2 STEAf1 GENERATOR ROM CottRN LOC FLAW LOCATI0tl FLAW HEIGHT (IllCHESI FLAW SIZE (%I DEFECT VOLTAGE 2
16 64 COLD TUBESHEET 3.3 13 0.88 2
16 65 COLD TUBESHEET 0.8 26 1.52 2
16 65 COLD TUBESHEET 2.7 12 2.47 2
16 66 COLD TUBESHEET 4.9 14 2.35 2
16 66 COLD TUBESHEET 2.7 6
3.77 2
16 67 COLD TUBESHEET 1.3 30 3.81 2
16 67 COLD TUBESHEET 2.5 17 3.28 2
16 68 COLD TUBESHEET 1.1 22 5.50 2
16 68 COLD TUBESHEET 2.6 5
2.94 2
16 69 COLD TUBESHEET 1.1 26 3.95 2
16 69 COLD TUBESHEET 2.3 4
2.51 2
16 70 COLD TUBESHEET 1.4 22 1.72 2
16 70 COLD TUBESHEET 2.4 7
1.91 2
16 71 COLD TUBESHEET 0.3 38 2.28 2
16 71 COLD TUBESHEET 2.1 16 1.74 2
16 72 COLD 2HD TSP 1.3 15 1.73 2
16 72 COLD 2HD TSP 2.4 8
2.74 2
16 73 COLD TUBESHEET 3.3 to 1.26 2
16 73 COLD TUBESHEET 2.3 6
3.50 2
16 74 COLD TUBESHEET 1.6 13 3.28 2
16 75 COLD TUBESHEET 1.3 21 4.56 2
16 76 COLD TUBESHEET 0.8 28 1.92 2
16 77 COLD TUBESHEET 0.8 29 3.18 2
16 78 COLD TUBESHEET 0.7 28 3.74 2
16 79 COLD TUBESHEET 1.1 22 1.31 2
16 79 COLD TUBESHEET 1.2 18 1.27 2
16 80 COLD TUBESHEET 1.3 8
1.23 2
16 81 COLD TUBESHEET 2.1 19 0.93 2
16 62 COLD TUBESHEET 1.5 9
1.55 2
17 13 COLD TUBE SHEE T 0.7 8
1.81 2
17 15 COLD TUBESHEET 0.7 30 2.96 2
17 16 COLD TUBESHEET 1.3 17 1.64 2
17 17 COLD TUBESHEET 1.0 2
17 17 COLD TUBESHEET
!.8 29 2.33 17 2.53 2
17 18 CotD TUBESHEET 0.5 34 2.08 2
17 18 COLD TUBESHEET 2.5
'O 1.52 2
17 19 COLD TUBESHEET 2.5 10 4.95 2
17 20 COLD TUBESHEET
!.8 19 2.15 2
17 21 COLD TUBESHEET 1.4 24 1.76 2
17 21 COLD TUBESHEET 2.2 22 2.09 2
17 22 COLD TUBESHEET 2.6 17 5.11 2
17 22 COLD TUBESHEET 4.2 9
4.55 2
17 23 COLD TUBESHEET 4.1 18 4.71 2
17 24 COLD TUDESHEET 2.6 1
3.71 2
17 25 COLD TUDESHEET 1.2 36 1.90 2
17 25 COLD TUBESHEET 3.6 14 2.12 2
17 25 COLD TUBESHEET 4.1 8
I.77 2
17 26 COLD TUBESHEET 4.1 19 2.77 2
17 27 COLD TUDESHEET 2.7 22 2.14 2
17 27 COLD TUBESHEET 3.8 7
2.24 2
17 28 COLD TUCESHEET 1.5 34 1.91 2
17 28 Coto TUDESHEET 3.6 12 3.33 2
17 29 COLD TUCESHEET 2.2 23 6.13 2
17 29 COLD TUBESHEET 3.5 2
3.18 1
SUP91 ART OF CV 1986 EDOT CURRENT INSPECTID'l DATA 0:19 WEDt350AY. 11 ARCH 5. 1986 24 LISTII:3 0F ALL TUBE FLAWS
=
FOR STEAtt GENERATOR 02 STEAfl GENERATOR 90W COLUP94 LOC FLAW LOCATION FLAW HEIGHT IINCHESI FLAW SIZE l%)
DEFECT VOLTAGE 2
17 30 COLD TUBESHEET 3.6 24 4.21 2
17 31 COLD TUBESHEET 2.2 27 3.63 2
17 31 COLD TUBESHEET 3.7 5
2.40 2
17 32 COLD TUBESHEET 2.2 22 3.92 2
17 32 COLD TUBESHEET 3.1 17 4.51 2
17 33 COLD TUBESHEET 0.6 9
3.38 2
17 33 Coto TUCESHEET 2.2 29 4.26 2
17 33 COLD TUBESHEET 3.4 13 2.21 2
17 34 HOT TUBESHEET 1.5 11 2.16 2
17 34 COLD TUBESHEET 2.1 22 4.76 2
17 34 COLD TUBESHEET 2.7 12 3.10 2
17 35 HOT TUBE SHEET 2.0 42 1.11 2
17 35 HOT IUBESHEET 7.0 5
1.17 2
17 35 COLD T'JEESHEET 1.7 29 2.82 2
17 36 COLD TUBESHEET 3.6 19 0.84 2
17 37 COLD TUBESHEET 2.0 22 2.48 2
17 37 COLD TUBESHEET 3.1 to 4.25 2
17 38 COLD TUBESMEET 2.1 17 3.09 2
17 38 COLD IUBESHEET 3.4 12 4.83 2
17 39 COLD TUBESHEET 2.8 14 4.51 2
17 40 COLD TUBESHEET 2.4 27 5.96 2
17 41 COLD TUBE SHEET 2.2 32 3.03 2
17 41 COLO TUBESHEET 3.4 9
4.12 2
17 42 COLD TUBESHEET 2.3 24 2.69 2
17 42 COLD TUBESHEET 3.4 16 2.67 2
17 43 COLD TUBESHEET 2.1 29 5.95 2
17 43 COLD TUBESHEET 3.5 17 3.35 2
17 44 COLD TUBESHEET 2.5 34 4.90 2
17 44 COLD TUBE SHEET 3.6 13 3.45 2
17 45 COLD TUBESHEET 2.5 34 2.78 2
17 45 COLD TUBESHEET 3.8 6
2.39 2
17 46 COLO TUBESHEET 2.1 17 3.09 2
17 47 HOT TUBESHEET 3.3 94 0.68 2
17 47 HOT 3RD AVB 0.0 12 1,29 2
17 47 COLO TUBESHEET 2.2 20 4.27 2
17 48 HOT TUBESHEET 2.7 18 1.56 2
17 49 COLD TUBESHEET 2.0 20 3.01 2
17 49 COLD TUBESHEET 2.6 7
2.78 2
17 50 COLD TUBESHEET 2.2 14 2.80 2
17 51 HOT TUBESHEET 1.0 71 1.45 2
17 51 COLD TUBESHEET 2.3 22 1.31 2
17 52 COLD TUBESHEET 2.3 22 1.36 2
17 53 COLD TUBESHEET 1.8 21 2.14 2
17 54 HOT TUDESHEET 7.7 43 6.16 2
17 54 COLD TUBESHEET 2.0 11 2.10 2
17 55 HOT TUBESHEET 7.8 24 3.15 2
17 55 COLO TUBESHEET 1.9 6
1.57 2
17 56 COLD TUDESHEET 1.8 17 1.35 2
17 56 COLD TUBESHEET 2.3 18 0.67 2
17 SS CotD TUBESHEET 3.1 14 1.53 2
17 59 COLD TUBESHEET
!.9 17 2.36 2
17 59 COLD TUBESHEET 3.3 9
2.94 2
17 60 HOT TUBESHEET 5.4 24 3.69 2
17 60 COLD TUBESHEET 1.4 25 3.12
Sur91ARY OF CY 1986 EDOT CLBRENT INSPECTIDH DATA 0:19 WEDHESDAY. MARCH 5. 1986 25 LI2 TING OF ALL TUBE FLAWS FOR STEAtt GENE 2ATOR C2 STEAM GENERATOR ROW COLLR94 LOC FLAW LOCATION FLAW HEIGHT IIHCHESI FLAW SIZE IX)
DEFECT VOLTAGE 2
17
- 0 COLD TUBESHEET 3.1 18 2.83 2
17 61 HOT TUBESHEET 5.4 38 4.35 2
17 61 COLD TUBESHEET 0.3 22 2.56 2
17 61 COLD TUBESHEET 2.8 5
3.11 2
17 62 COLD TUBESHEET 1.3 26 2.89 2
17 62 COLD TUBESHEET 3.2 12 1.99 2
17 63 COLD TUBE SHE ET 1.4 24 5.06 2
17 63 COLD 1UBESHEET 3.3 12 1.03 2
17 64 COLD TUBESHEET 1.3 22 3.67 2
17 64 COLD TUBESHEET 2.9 13 1.35 2
17 65 COLD TUBESHEET 0.8 28 1.87 2
17 66 COLD TUBESHEET 1.4 29 2.50 2
17 66 COLD TUEE SHE ET 2.6 17 3.23 2
17 67 COLD TUBESHEET 1.2 21 2.69 2
17 67 COLD TUBESHEET 2.5 16 2.80 2
'17 68 COLD TUBESHEET 1.3 21 5.85 2
17 68 COLD TUBESHEET 2.5 7
3.94 2
17 69 COLD TUBESHEET
!.3 24 3.34 2
17 69 COLD TUBESHEET 2.3 16 2.98 2
17 70 COLD TUBESHEET 1.4 29 2.16 2
17 70 COLD TUBESHEET 2.7 15 4.02 2
17 71 COLD TUCESHEET 4.4 47 2.65 2
17 71 COLD TUBESHEET 2.7 7
2.86 2
17 72 COLD TUBESHEET 4.4 11 2.30 2
17 72 COLD TUBESHEET 2.6 7
3.77 2
17 74 COLD TUBESHEET 1.3 16 3.51 2
17 74 COLD TUBESHEET 2.5 13 2.72 2
17 75 COLD TUBESHEET 1.4 24 3.81 2
17 75 COLD TUBESHEET 2.5 15 1.31 1
2 17 76 COLD TUBESHEET 4.6 18 4.85 2
17 77 COLD TUBESHEET 2.6 3
1.11 2
17 78 COLD TUBESHEET 8.8 14 2.94 2
17 79 COLD TUBESHEET 2.0 20 1.18 2
17 80 COLD 2HD TSP 1.9 5
2.25 2
17 81 HOT 2HD TSP 9.8 5
1.88 2
17 83 HOT 3RD TSP 1.6 2
1.40 l
2 18 7
HOT TUBESHEET 6.0 11 2.58 2
18 16 COLD TUBESHEET 0.5 15 2.85 2
18 17 COLD TUBESHEET 0.8 51 1.66 2
18 17 COLD TUBESHEET 1.4 20 3.02 2
18 18 COLD TUBESHEET 1.2 37 4.65 2
18 19 COLD TUBESHEET 2.5 8
3.54 I
2 18 20 COLD TUBESHEE1 2.5 12 2.15
)
2 18 21 COLD TUBESHEET 2.1 14 2.73 2
18 22 COLD TUBESHEET 2.3 4
2.90 2
18 22 COLD TUEESHEET 4.2 18 3.22 2
18 23 COLD TUBESHEET 2.2 21 2.44 2
18 23 COLD TUBESHEET 3.9 12 4.08 2
18 24 COLD TUBESHEET 2.4 15 2.48 2
18 24 COLD TUBESHEET 4.1 6
2.68 1
2 18 25 COLD TUBESHEET 4.3 7
3.72 2
18 26 COLD TUBESHEET 2.2 2
2.81 2
18 26 COLD TUBESHEET 4.0 3
3.12 2
18 27 COLD TUBESHEET 3.8 18 1.87
SLRetARY OF CY 1986 EDOV CURRENT IHSPECTION DATA 0:19 WEDtE50'.Y ItARCH 5,1986 26 LISTII:3 DF ALL TUBE FLAWS
- ~
g FOR STEAft GENERATCR 82
~
STEAM GEHERATOR ROW COL 1294 LOC FLAN LOCATION FLAW HEIGHT IIHCHESI FLAN SIZE 123 DEFECT VOLTAGE 2
18 28 COLD TUBESHEET 3.8 15 2.98 1
2 18 29 COLD TUBESHEET 1.6 35 1.04 2
18 29 COLD TUBESHEET 3.8 2
2.98 i
2 IS 30
'CotD TUBESHEET 2.2 20 6.41 2
18 30 COLD TUBESHEET 3.3 26 3.48 1
2 18 31 COLD TUBESHEET 2.4 26 1.78 2
la 31 COLD TUBESHEET 3.3 4
2.18
)
2 18 32 COLD TUBESHEET 3.1 7
5.55 2
18 33 COLD TUBESHEET 3.7 3
3.77 2
18 33 COLD TUBESHEET 1.9 18 2.12 2
18 33 COLD TUBESHEET 3.2 11 3.36 2
18 34 COLD
-TUBESHEET 1.6 28 0.79 2
IS 34 COLD TUBESHEET 2.2 11 2.11 2
18 35 HOT TUBESHEET 2.2 15 0.72 2
18 35 COLD TUBESHEET 3.6 38 1.12 2
18 36 HOT TUBESHEET 2.4 18 1.65 2
18 36 COLD TUBESHEET 3.0 7
2.74 2
18 37 COLD TUBESHEET 0.6 26 1.82 2
18 37 COLD TUBESHEET 3.1 4
3.59 l
2 18 38 COLD TUBESHEET 3.2 16 6.18 4
2 18 39 HOT TUBESHEET 3.1 17 1.45 t
2 18 39 COLD TUBE 5HEET 1.8 25 2.59 l
2 18 39 COLD TUBESHEET 3.2 13 2.66 i
2 18 40 COLD TUBESHEET 1.9 25 3.85 2
18 40 COLD TUBESHEET 2.5 20 2.81 2
18 41 COLO TUBESHEET 2.0 25 5.39 1
2 18 41 COLD TUBESHEET 3.4 5
3.26 l
2 18 42 COLD TUBESHEET 1.9 22 3.79 2
18 42 COLD TUBESHEET 3.3 14 2.56 l
2 IS 43 HOT TUBESHEET 1.1 94 1.10 1
2 18 43 COLD TUBESHEET 2.2 17 4.33 2
18 43 COLD TUBESHEET 3.4 12 1,66 i
2 18 44 COLD TUBESHEET 2.I 24 3.18 1
2
~
18 44 COLD TUBESHEET 2.4 29 2.36 2
18 45 HOT 1UBESHEET 1.1 52 8.91 2
18 45 COLD TUBESHEET 2.4 22 2.23 2
18 45 COLD TUBESHEET 3.5 16 3.97
+
2 18 46 HOT TUBESHEET 4.9 96 1.33 2
18 46 COLD TUDESHEET 2.1 17 3.57 i
2 18 46 COLD TUBESHEET 3.5 9
2.77 i
I 2
18 47 HOT TUBESHEET 6.2 9
2.16 I
2 18 47 COLD TUBESHEET 2.2 19 3.75 l
2 18 45 COLD TUBESHEET 2.1 23 4.12 3
2 18 49 COLD TUBESHEET 2.1 24 4.93 2
18 49 COLD TUBESHEET 2.6 18 1.57 2
18 50 COLD TUBESHEET 1.9 15 4.38 2
18 50 COLD TUBESHEET 2.4 3.15
{
2 18 51 HOT TUBESHEET 3.7 11 0.90 i
2 18 51 COLD TUBESHEET 2.2 33 2.21 2
18 52 COLD TUBESHEET 2.2 25 1.94 2
18 53 COLD TUDESHEET 1.8 29 5.26 2
18 53 CotD TUBESHEET 3.3 10 2.55 2
18 54 COLD TUBESHEET 1.7 20 2.70 2
18 54 COLD TUBESHEET 2.2 20 1.15
]
SLRt1ARY OF CV 1986 EDDT CtRRENT INSPECTION CATA 0:10 WEDHESD*.Y.11 ARCH 5,1986 27 LISTING OF ALL TUBE FLAWS FOR STEAN GENEIATDR 82 STEArt GENERATOR ROM COLtR94 LOC FLAW LOCATION FLAW HEIGHT IIHCHESI FLAW SIZE 123 DEFECT WOLTAGE A
2 18 55 COLD TUBESHEET 1.6 23 4.11 2
18 55 COLD TUBESHEET 3.2 5
1.37 2
18 56 COLD TUBESHEET 1.4 14 2.62 2
18 56 COLD TUBESHEET 3.2 7
1.80 2
18 57 COLD TUBESHEET I.5 21 1.67 2
18 57 COLD TUBESHEET 3.2 3
2.87 2
18 59 COLD TUBESHEET 1.6 15 3.49 2
18 60 HOT TUBE 5HEET 5.3 24 2.05 2
18 60 COLD TUBE SHEET 1.3 21 2.47 2
18 60 COLD TUBESHEET 3.0 14 4.30 2
18 61 COLD TUBESHEET 1.2 25 2.78 2
18 61 COLD TUBESHEET 2.8 3
2.92 2
18 62 COLD TUBESHEET 1.2 24 2.74 2
18 62 COLD TUDESHEET 2.6 14 2.09 2
18 63 COLD TUBESHEET 0.2 47 1.35 i
2 IS 63 COLD TUBESHEET 2.4 5
2.93 l
2 18 64 COLD TUBESHEET 1.3 22 4.01 2
18 65 COLD TUBESHEET 1.1 37 1.81 l
2 18 65 COLD TUBESHEET 2.6 9
1.46 2
18 66 COLD TUBESHEET 0.6 31 1.01 2
18 66 COLD TUBESHEET 1.4 18 2.21 2
18 67 COLD TUBESHEET 0.7 41 1.39 2
18 67 COLD TUBESHEET 2.4 8
3.30 2
18 68 COLD TUBESHEET 1.1 32 5.85 2
18 62 COLD TUBESHEET 2.6 12 3.44 2
18 69 COLD TUBESHEET 0.9 30 1.97 2
18 49 COLD TUBE SHEE T 2.8 7
3.75 2
18 70 COLD TUBESHEET 1.1 29 4.37 2
18 70 COLD TUBESHEET 2.7 11 4.08 2
18 71 COLD TUBESHEET p.4 41 1.93 2
18 71 COLD TUBESHEET 2.7 9
3.23 2
18 72 COLD 2HD TSP 2.7 6
2.01-2 IS 7*
COLD TUBESHEET 0.4 33 1.79 2
18 73 COLD TUBESHEET 1.3 15 2.89 2
18 73 COLD TUBESHEET 2.7 3
3.49 2
18 74 COLD TUBESHEET 1.8 19 1.10 2
48 75 COLD TUBESHEET 1.3 25 2.30 2
18 76 COLD TUBESHEET 0.9 25 4.06 2
18 77 CotD TUBESHEET 0.9 3
1.37 2
18 78 COLD TUBESHEET 0.7 18 4.40 2
18 79 COLD TUBESHEET 1.4 9
2.36 2
18 80 COLD TUBESHEET
!.9 19 1.37
(
2 18 82 COLD TUBESHEET 1.6 2.49 2
18 87 HOT 3RD TSP 5.1 39 1.34 l
t 18 87 HOT 3RD TSP 7.1 23 1.22 l
2 19 18 COLD TUBESHEET 1.1 15 3.90 2
19 19 COLD TUBESHEET 2.2 5
3.47 2
19 20 COLD TUBESHEET 2.3 2
2.14 I
2 19 21 COLD TUBESHEET 1.7 10
_2.39 2
19 22 COLD TUBESHEET 4.1 22 1.12 2
19 23 COLD TUBESHEET 3.9 19 2.58 2
19 24 COLD TUDESHEET 2.6 3
4.55 2
19 25 COLD TUEESHEET 2.6 Il 2.32 2
19 25 COLD TUBESHEET 4.4 5
2,14
St291ARY OF CY 1986 EDDT CLRRENT IH5PECTI0t4 (iiATA 0:19 ME"::lESDAY. 91 ARCH 5. 1986 23 LISTIt:G OF ALL TUBE FLAWS F0lt STEAM GENC ATON C2 STEArt GENERATOR ROM COLUP94 LOC FLAM LOCATION FLAW HEIGHT (IHCHESI FLAW SIZE IXI DEFECT VOLTAGE 2
19 26 COLD TUBE 5HEET 3.9 2
4.43 2
19 27 COLD TUBE 5HEET 3.8 11 2.97 2
19 28 COLD TUBESHEET 1.9 14 2.99 2
19 28 COLD TUBE 5HEET 3.7 9
2.15 2
19 29 COLD TUBE 5HEET 3.4 9
3.36 2
19 30 COLD TUBE 5HEET 2.1 le 5.24 2
19 31 COLO TUBE 5HEET 2.2 24 3.82 2
19 31 COLO TUDE5HEET 2.4 21 1.19 2
19 32 COLD TUBE 5HEET 3.2 7
3.75 2
19 33 COLD TUBE 5HEET 3.3 16 2.90 2
19 34 COLD TUBE 5HEET 2.4 16 0.77 2
19 35 COLD TUBE 5HEET 2.7 15 1.54 2
19 36 COLD TUBE 5HEET 1.9 15 2.53 2
19 37 COLD TUBE 5HEET 2.2 9
2.93 2
19 38 COLD TUBE 5HEET 2.2 26 3.02 2
19 39 HOT TUBE 5HEET 2.8 19 1.51 2
19 39 COLD TUBE 5HEET 1.9 19 2.06 2
19 39 COLD TUBE 5HEET 3.2 17 2.04 2
19 40 COLD TUBE 5HEET 2.5 23 2.95 2
19 41 COLD TUBE 5HEET 2.1 21 3.87 2
19 42 COLD TUBE 5HEET 2.1 17 4.10 2
19 43 COLD TUBE 5HEET 2.5 21 4.28 2
19 44 COLD TUBESHEET 2.6 29 3.26 2
19 45 COLD TUBE 5HEET 5.6 31 0.72 2
19 46 COLD TUBESHEET 2.3 21 4.13 2
19 46 COLD TUBE 5HEET 3.7 5
1.86 2
19 47 COLD TUBE 5HEET 2.0 17 3.47 2
19 48 COLD TUBE 5HEET 2.1 18 3.21 2
19 49 COLD TUBE 5HEET 2.0 13 4.20 2
19 50 COLD TUBE 5HEET 2.4 19 2.05 2
19 51 HOT TUBE 5HEET 12.6 38 2.77 2
19 51 COLD TUBE 5HEET 2.2 19 3.59 2
19 52 HOT TUBE 5HEET 4.0 12 3.00 2
19 52 COLD TUBE 5HEET 1.7 16 3.29 2
19 52 COLD TUBE 5HEET 2.9 10 -
1.14 2
19 53 COLD TUBE 5HEET 0.4 32 1.51 2
19 53,
HOT TUBE 5HEET 3.6 14 0.87 COLD TUBE 5HEET
!.7 28 5.81 2
19 54 2
19 54 HOT 2HD TSP 26.0 27 19.54 2
19 54 COLD TUBE 5HEET 1.8 23 3.22 2
19 55 COLD TUBE 5HEET 1.7 15 4.46 2
19 55 COLD TUBE 5HEET 3.2 9
1.64 2
19 56 COLD TUBE 5HEET 2.0 33 1.03 2
19 56 COLD TUBE 5HEET 3.4 5
1.60 2
19 57 COLD TUBE 5HEET 1.5 22 4.02 2
19 58 COLD TUBE 5HEET
!.3 22 3.94 2
19 59 COLD TUBE 5HEET I.4 17 5.55 2
19 60 COLD TUBE 5HEET 3.3 32 3.76 2
19 60 COLD TUBE 5HEET 2.7 16 4.73 2
19 61 COLD TUBE 5HEET
!.3 27 2.41 2
19 61 COLD TUBE 5HEET 3.0 8
3.03 2
19 62 COLD TUBE 5HEET 1.1 26 2.18 2
19 62 COLD TUEESHEET 2.7 17 3.45 2
19 63 COLD TUBE 5HEET 1.6 27 2.99
~
r' e
-6 e
O N
W m
N d
mMmeNMmeNmmMMOMO M. m. M. *. N. N.N. e. e. e. e. d. e. S.e.. N M G M f O e C. N e h e m e d m @ N 4 4 N e O O M N m 4 N 4 W W @ @ N O 4 WN. r.
. m. m. n. e. O. 4. e.
3g mMNNN4MfN444N4MfMMMMMMMadmNMmNmmmmmmNmNNNNmNNNNmNmfWmm N
E bw O
d O
Vs U
m 5
N y
a w
O N
=..
deMMMeeemeN4NeefoMemeedde4mhe#CPONNfwebmNfMmeGe44MmCWN m
M mNNNmNmNmNmN SJmNmN NmNN MmmmmNm m
fm N
mm Mmm m
O 24a b
i 4-d O
O w3 e5 B
m n
w
$. @. d. M. m. m.h.ee. N. N. h. M. N. O. N. O. G. W. W. N 4. N. M. e. @. @. @. @. e. N. a. @. @. @. @. @. O. 4. M.e. m. p f. N. e. m. m. e. 4 0. m. m.W. N.
uw aW T
NaNMNmNmNmNmNmNmNONmNumNOmMOMmMafMetOM99mmNN44(MmMNNNN
@2N G
N
=
Z49 m
na W
>Zw-2 w e e!
4 3r1 a
kg aC JG
>48.5 b
->>>>>>>>>>>>>wh>>>>>>>>>>>>>>>>>>
wow-
>>>->>>>>>www>k go wwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwww wwww g:_8 wwwwwwwwgwwwwwwwwwwwwwwwwwwwwwwwwwaaaaawww wwowwwww.ww 5 5 5555555555555555500:00555555ywwwwwgww ww ww 55555,5555555
.55555.55 m.
8 wwwwwwwwwwwwwwwwwwwwwwwwwwwwwww
- www.wwwwwww.www W:
EBBBBBBBBBBBBBBBBB$BBBBBBBBBBBBBBBB"R""ABBBBBB8BBBBB998 M-------->->---
-->------>----NR R
2
-->--------m--
B 5*
2 0000000S00D000000000000 0C O
O O
GO aaaaaaaaaaaaaaaaaaaaaaawaanawaka>>>>>www.OOOOOQmAOOOOc U
a-aaaaaaaaaaa O
C0000000000000000000000000000000000000000000000000c050 a
uuuuuuuuuuuuuuuuuuuuuuuZuuZuzuzu24XZZZZuuuuuuupuuuuuud 6
w a
&4 mm h
44 m
- hh a
h m
h 444$4e4444444 NNNNNNNNNNNNNNNNN494G444@ pem=NNNNNNNNMMMM C
u
@@pepepeeeepepemeeppepepe@@@epepe>@ ePeewOOOOOhemO404Co m m e m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m e m m N N N en N w N N e4 N N N N N N 8
48r w
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNQNWHNNNNNNNNNNN%NNNNNNN C
4 t
W e
4 1
l l
\\
M i
M m
4-e d
m O
@@NOGmNmMGmfGd4fN@@dNNamNm@@mef@mmWmoofMmNWNmeCfoodoNo g
M. M. e. m. b. m. e. @. @. N. m. O. f. m. e. M. P. O. N. @. m. m. 4 4. f. f. m. S. @. N. f. d. M. w. M. f. f. f. o. N. N. e. h. f. N. m. M. N. G. @. m. m. o. M.
u mmNNNmN~NNNMmfNNNMommmuMmMmmemMoMmmmNMNffMuMMMNNN~Nmpo W
+
E b
b O
1 OmW
=
8 x
I
~
m O
N m..
NNNmSGfoNwNfbNN4f@SSN42@m@mdNfNmbemfG@MNf@fmM@NNfCm-oC
-m mmmmmmmNm N
mNNNmmNNmNmmmmNNmmNmmmmu NmNN Nmm y m M m ee m os u 9
24a 6
<1 a
4 m
O W
3 m5 M
w
- m. e. O. @. o. m. m. m. N. M. 4. N. N. M. P. M. f. f. m. M. m. e. w. o. m. e. t. N. @. N. @. N. 4. N. 4. f. M. M. N. e. f. @. @. S. N. O. N. O. W. N. N. @. M. M uw 4
NNNmHMNNeeMNNNNMNMNNNNSNNNmNNMNmMmMNmNMNwmNmNmumMwNmNmW E4.
M
-a b
E EN-2
.un tDM d
$g b
a.
WW
-4 Es! s
...---.-----N--------------------------------------
3um
.w
...--Nmmmm.m..wm....
-m.
..mm m..
..m u-u-~qm....
m.m.m...
..... m m m m m....
m..
8
..44.b..
.M.$
U %
9.
4 E
...mummommm.&.
mm
.mmmm-wm
.mmNo.-m 0*
EP2BE9888888 FEBBBB998E e89W598$$888BBBBBBE!8859888$8 8
- - - - - - - - N e - - - - - - -
3~ B
-n-----------------------
=
8 Us e
p cc MDnOGCCOCOOOOOC C 000000 O COAO GO00000000C04:000000 u
eeeaa a s a d u m a a a a e d - J 'n a e a a a a
- - w a s a w a -J a a a a - a a a a a a u w w a m.a s
O Qo009800000u00000000000D0000pt3000000000000000000000000 d
wuzuwuyuuuuuuuuuuu2QZuuuuuututuvuuzuuuuuuuuuuuuuuuuuuu E
3 n e N m e e m o m m N e.r m m f a N e c e @ e o o m N M M f f f m e s e s N - e n @ o o m m N N M M -s. m e g
MMMMMMMfffffff#ffffffffmmmmmmmmmmmmmmmmmmme@444ded@44@
s v
b o s a. c e e n o p e n e o o o n o o o o o o n e n e o c o o o o e e n a n o c o o o c o n o o n. m H N N,c o cou
~N N-N~NNNNNNN~NNNNNNNNNN NNNNNNN~NNNNNNNNNNNNN.
~
E 1
4 NNN~NNN~NNNNNNNNNNNN NNNN,NNNNNNNNNNNNNNNNNN NNNNNNNNN e
W e
e
.._,r
,, _ _ =. _.,,.
_.e..
}
-m I
3
-a9~<~..A.<..,~.~R..............~.~.,e*,,m~.~<-e......,<~m,...,, e <.. ~.. ~.... s.
< e. e. m. ~..
-NN-4MfM.< ~. ~.,.
.,...~e...e..~..
.. ~. ~.. ~...
3 Mf.dNN--~
-t-.---M-MN
.-NM-M-MNfMNN-NN-NW.-NN U
k u
4 W
E h
W O
4 Sw a
n W
W o
~
M -. e m, ~. A. ~ m e > ~ 4 e e m e m - e e.. e - e. ~ e. m h e m. m. e k. e e. m e. N.. e - m
-r-~
e
~-n---
-~---~
m--
- ~--- - - ---~- ----
3aa W
e.
o o
W b
-8 m
s g,,
. e.. n e. u. n. u. n ~. n. e m. u.. n.. - n.
.. < a. n.. ~..... m. m. n.. m. n u. ~. e. r..
n.
- m. r... n. m.
u
~<
W e
e o
e e
e
-~-u-~-~--mu-m-.-<.-.----~~~~~~~~-~~~~~m
~~~~~~~~~
.~
5 fu MJ W
- 5 Wg.-
2 ZW 0
2 JW aa
-eS E WBW 5
{g. ;
WWWWWWWWWW WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW g e W W W W W W W W g g W W y w w W. 5 W w W W.g y W g w W W W W W W W g W W W w w w w e g g g w W y W y W g
mWWWWWWWWWWWW.5a555a555amaa55aaaaamama.aa5 maka55m555-55.5555 5555 a
--E 8
==
WWWWWWWWWWWWwWWWWWWWWWWWWWWW WWWW.mW WW E$$$ EBB'BBBBBBBBBBBBBBBBBBBBEEBBBBBBBBBBBBBBBBBBBBB$BB C'J d--~~----------------
B W
i
S DDDDCDDDODOODDD DC COCCCDODDQD C
DDDDDDDDDDDDDDGD DDQ
aa------
u0 000c00000000000000000000000000000000000000000000000000 w
Uuutuuuuuuuuuuuuuuuuuzuuuuuuuuuuuuuuuzuumuuuuuuuuuuu2W 5
.n.n.e.ee...--~mme..
~.....ee.~m
..-~.~.ee
.--~m.s..
nne.
--~~~~~------~~.--..-~~~-men--mm ra..
Ou E ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
5 4
E r
\\
W
~ a. ~ ~ e. ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ u ~ ~ ~
E 9W-.
e
SLO 91 ART OF CY 1966 EDDT CLRRENT INSPECTION DATA 0:10 WEDf4ESDAT. t1 ARCH 5. 1984 32 LISTING OF ALL TUBE FLAWS
+
+
FOR STEAN GENEZA10R 82 STEaN GENERATOR WOW Cott###
LOC FLAW LOCATION FLAW HEIGHT (INCHESI FLAW STZE (%)
DEFECT VOLTAGE 7
21 50 HOT TUBESHEET 2.8 21 2.51 2
21 52 COLD TURESHEET 2.4 12 3.54 2
21 51 COLD TUBESHEET 2.6 19 1.50 2
21 52 COLD TUBESHEET 2.7 22 1.35 2
21 53 HOT TUBESHEET 2.9 18 1.52 2
21 13 cot 0 TUBESHEET 2.2 24 4.23 2
21 53 COLD TUBESHEET 3.3 18 3.65 2
21 54 C010 TUBE SHEET 1.7 26 4.34 2
21 54 COLD TUBESHEET 3.7 6
1.52 2
21 55 HOT TUBESHEET 1.6 12 0.63 2
21 55 C0tB TUBESHEET 1.6 19 3.78 2
21 55 COLD TUBESHEET 3.0 9
1.69 2
21 56 CotD TUBESHEET 1.4 22 2.91 2
21 56 COLD TUEESHEET 2.9 18 1,43 2
21 57 Coto TUBESHEET 1.4 23 2.54 2
21 58 COLD TUBESHEET 1.3 18 4.32 2
21 58 COLD TUBESHEET 2.8 12 1.06 2
21 59 CotO TUBESHEET
!.3 25 5.07 2
21 59 CotD 1UBESHEET 2.7 13 3.40 2
21 60 HOT 3RD TSP 13.7 14 1.92 2
21 60 COLD TUBESHEET 1.4 26 5.27 2
21 60 COLD TUBE 5HEET 2.7 15 4.30 2
21 61 C04D TUBESHEET 1.3 31 2.41 2
21 62 COLD TUBESHiET 1.9 31 2.24 2
21 62 COLD TUBE 5 HEFT 2.0 31 2.24 2
21 62 CCLD THEESHEET 3.3 to 1.03 2
21 63 COLD TUBESHEET 1.7 31 5.30 2
21 64 C010 TUBESHEET 1.7 28 3.42 2
21 64 COLD TUBESHEET 3.3 26 1.04 2
21 65 COLD TUBESHEET 1.6 14 6.19 2
21 66 COLD TUDESHEET 4.8 34 2.65 2
21 66 COLO TUBESHEET 1.6 22 4.86 2
21 67 COLO TUBESHEET 0.2 24 3.47 2
21 67 COLO TUBESHEET 1.3 16 4.90 2
21 68 COLD TUC16HEET 1.4 15 5.82 2
21 68 CotB TUBtSHEff 2.8 6
3.20 2
21 69 COLD TUBESHEET 1.3 14 7.58 2
21 69 CotD TUBESHEET 3.0 le 2.25 2
21 70 C010 TUCESHEET 1.4 17 2.72 2
21 70 COLD TUGE2HfET 3.0 6
3.37 2
21 71 COLD TUBESHEET 1.5 26 3.78 2
21 72 COLD TUBESHEET 1.4 18 5.31 2
21 73 C010 TUBESHEET 1.3 17 2.40 2
21 74 COLD TUBESHEET 1.3 7
2.26 2
21 75 COLD TUeESHEET 4.7 20 2.60 2
21 76 COLO TUBESHEET 1.3 39 1.06 2
21 77 COLD TUBESHEET 0.9 1
4.57 2
21 78 COLD TUBESHEET 2.0 17 0.71 2
21 79 HOT TUEE SHE ET 1.1 10 4.94 2
21 79 COLO TUBESHEET 0.5 32 1.75 2
21 80 HOT TUBESHEET 1.3 26 6.68 2
21 80 COLD TUBESHEET 0.4 9
1.20 2
21 81 C010 TUBESHEET 0.4 18 3.01 2
22 18 COLD TUBESHEET 0.8 7
1.27
SLNttART OF CV 1986 ED0Y CL5tRENT INSPECTIDH CATA C:19 WEDHESO4T, itARCH 5.1986 33 LISTIIEL OF ALL TUBE FLAhm FOR STEAtt GEHE ATOR 82 STEAM GENERATot ROW Coltste LOC FLAW LOCATION FLAW HEIGHT IIHCHESS FLAW SIZE (ZI DEFECT VOLTAGE 2
22 19 COLD TUBE 5HEET 1.3 9
1.69 2
22 20 COLD TUBESHEET
!.0 5
3.45 2
22 22 COLD TUBE SHEET 1.5 la 1.65 2
22 23 COLD TUBESHEET 1.9 7
2.54 2
22 24 COLD TUBESHEET 3.0 3
1.86 2
22 26 COLD TUBESHEET 3.8 3
1.89 2
22 27 COLD TUBESHEET 3.9 27 1.35 e
2 22 28 COLD TUBESHEET 3.0 6
3.39 2
22 29 COLD TUBESHEET 3.1 6
1.56 2
22 31 COLD TUBESHEET 2.4 15 3.10 2
22 33 COLD TUBESHEET 3.9 8
- 1. 94 2
22 34 COLD TUBESHEET 2.5 26 0.64 2
22 35 COLD TUBESHEET 2.3 5
1.76 2
22 36 COLD TUBESHEET 2.4 14 2.66 2
22 37 COLD TUBE SHEET 2.3 3.49 2
22 37 COLD TUBESHEET 3.5 8
2.15 2
22 38 HOT TUBESHEET 1.2 17 1.62 2
22 38 COLD TUBESHEET 2.2 17 3.30 2
22 40 COLD TUBESHEET 2.6 26 0.87 2
22 41 HOT TUBESHEET 2.2 8
1.93 2
22 41 COLD TUBESHEET 2.5 to 2.37 2
22 41 COLD TUBESHEET 3.4 12 1.41 2
22 42 HOT TUBESHEET 2.3 12 1.83 2
22 42 COLD TbdESHEET 2.6 25 2.94 2
22 43 COLD TUBESHEET 2.1 12 3.26 2
22 43 COLD TUBESHEET 2.6 17 2.80 2
22 44 COLD TUBESHEET 2.7 10 1.82 2
22 45 COLD TUBESHEET 3.7 10 1.87 2
22 46 COLD TUBESHEET 2.5 13 4.02 2
22 46 COLD TUBE SHEE T 3.8 2.14 2
22 47 COLD TUBESHEET 3.7 22 1.92 2
22 48 COLD TUBESHEET 2.3 17 3.51 2
22 48 COLD TUBESHEET 3.5 6
1.98 i
2 22 49 COLD TUBESHEET 1.0 22 0.88 2
22 49 COLD TUBESHEET 3.4 4
2.!!
2 22 50 COLD TUBESHEET 3.4 8
1.39 2
22 51 CotD TUBESHEET 2.9 25 0.96 2
22 52 COLD TUBESHEET 2.1 16 1.87 2
22 53 COLD TUBESHEET 2.2 23 4.05 2
22 54 HOT TUBESHEET 3.1 24 0.98 2
22 54 HOT TUBESHEET 1.5 12 1.12 2
22 54 COLD TUBESHEET 3.0 18 1.11 2
22 55 COLD TUBESHEET 2.8 8
2.46 2
22 56 COLD TUDESHEET
!.9 19 2.64 2
22 56 COLD TUCESHEET 2.8 7
2.36 2
22 57 COLD TUBESHEET 1.6 14 3.43 2
22 58 COLD TUBESHEET 1.8 17 1.15 2
22 59 COLD TUBESHEET 1.6 7
3.48 2
22 60 COLD TUEE SHE E T 1.4 20 4.52 2
22 60 COLD TUBESHEET 2.7 13 1.84 2
22 61 COLD TUBESHEET 1.4 17 3.53 l
2 22 62 COLD TUBESHEET 1.9 25 0.96 2
22 62 COLD TUEESHEET 3.5 13 1.32 2
22 63 COLD TUBESHEET 1.0 27 1.36
4 0
9 5
l 3
A m
o 4.GM.ehee.aemNNNNema.eameeNNNmne-a-NreMNoeMmeMmemM.M MN emer
. N e O.*. m. m e N. @. N. M e e. m. t e e. e. e d.f. e. f. d e.e.d e. N. M. m. e. e. d. f. e. e d.
e e. m. m. 4 4 4. &. N. O @ m.
3 e e e e e e e e e e e
e e
e e
e k
N-NmNmmM-MNfNfNM-N-m-ONm-Nmad@N40mwMmNmCOMMwfNMNmmmmM4 uw wW e
Q 4
r w
N B
~
w O
N
=..
esemdhmeteNN-64@dPPfeNOmmMeedMdNNNNNPPN@MSN46&S@ePON4N 2
-N-mNmNmN=Nm NM M
NM Mm NfN te m m
N m M m m m m m N ed e m N N tJ 23 w
d-m 4
u w
b
=
m-m
- e. d. e. P. e e. d. e. d. @. N. 4. N. f. m. m. m. H. N. e. e. O. f. O. m. N. N. m. M. N.4. m.. @.e. @. d. N =. N. #. 4. m. M. 4. @. e. m. m. e. d. N. G. O.
u
- w N -.e e
I_ g
--MNNm-N-mmN-.M..-M.M.....-M.-M-<<<NMNMN#MmNMNmNN Ma W
5 Zw-g4 aw 5s, N
ae M4 8 85 b
- we m
wwww wwww wwwwwwww ww wwwwwww.www www.wwwwwwwwwwwwww.m g :. 8 wwwwwwwwwwwwwwwwwwwwwgwwwwwwwwwwwwwwwwwwwww ww.wwwwwww ww5555555555555555555.55555555555555555555555555555555 55 8
m ow wwwwwwwwwwwwww www w
wwwwwwwwwwww wwww.wwww wwww w
IBBBBBBbBB B I +BbBBBEB"BBBBBESBBbBE999888 SBBBBWB888 B
u
~~~~ ----
~ -
-~~""
- ---8-~~~
5
~~~~~
8 a-COOOOOOOOOOOO 800 200 OOOOOO O.0000200 UGOOO O
C00 00 u
a a a a a a a a a a a a a - a a a se w a a n s a a a a a - - a = a.a m a a w a n a w a s -d - a - a - a - a a O
000000000000000000000740c00000000000000000000000000000 a uuuuuuuuuuuuutuuuzuuu2uvuuuu2Euuuuuuuuu2OuuuutuZuuQ1uu MaddedNNee@Oe==NNMMMdmmm44NPOMemMemP-mNMMM#meNNeempegm a
ed4@@@d4@@@NNNNNNNNNNt=NNNNNNeeWNNNNNMMMMMMMMMMMMMMMff4 Ou N N N N e4 N N N N N N N N N N ed N N N N N N N N N N N N N N N M M M M M M M M M M M M M M M M M M M M M M M m
N N N N N N N N N N N N N N N N N N N N N N N N N N N ts N N N N 94 N N N N N N N N N N N N N N N N N N N N N 5-4 E
Ig N N N N N N N N N N N N N N N N N N N N N N N N N N tJ N #4 4 N N N N N N N N N N N N N N N N N N N N N N N N w-e e
53 68 C
9 G
1 A
T L
5 O
9647L91&4514796152095125954164355654672974594165932428 W
108461263437521427135838706170561483129947442804839765 H
C T
321243124221212031212131038221221122133211145282333212 R
C A
E t
I F
E D
Y A05 EH
)
D E
8 l
E J
Z 1
I 5092964411463263845958376250647544698416995e1138245987 S
2212111112 323122 2
21213132341 2
1 2211 2l2 312 21 1
0 N
AL F
a T
I 6
S D
EH H
C S
N I
I T
(
C 640666862462241 412364864059545524375044326716163416596 E
T PS H
2342223222322S3123251213113134I313133113118313331311I1 SW2 G
NA8 I
IL E
FR H
T O
NET M
EBI A
WtR L
RiE F
U N
CLELG YA O M SFA ESE N
T O
TTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTiTTTTTTTTTTTTT 6sC I
EEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE 9t T
EEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE t
9IR A
HHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHhHHHHHHH 1TO C
SS55S5555S555555555S955555555555S55S555555555555555$5S 2F O
EEEEEEEEFEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE BBBBBBBBBBBBDBBBBDBDBBBBBBBBBBBBBBBBBBBEBBBBBBBBBBBBBB Y3 L
uUUUUUUUUUUUUuUUuUUUuUuUUUUUUUUUUUUt UUUuUUUUUUUUUUuUUU CL M
TTTTTTTTTTTTTTTTTTTYTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTT'I F
A O
L F
Y R
A tee BsaDsD3BB sSDS aea05BDD aOOD BBsBDO DBeDDDOooODBOBc0O t
C tltLtLtttTTtLLLTtttt0tLLTtLLLTtttttLTLtt LL t Ltttt tLt t lL S
O CooOoO0ooCOoOOOOoooo00OOOoOOOO0ooOoOOOooOOoOo0oo0O00oO L
CCCCCCCCCHHCCCCNCCtCCCCCHCCCCNCCCCCCNCCCCCCCCCCCCCCCCC M
f 233456674994122333446677889441112233445566774899001235 t
t 444444446445555555555555555666666666666666666666777777 o
C NO 333333333333333333333333333333333333333333333333333333 S
222222222222222222222222222222222222222222222222222222 m
i T
A R
EN E
222222222222222222222222222222222222222222222222222222 G
tfA ETS
l
[4 I
63 68 E
9 G
1 A
T L
5 O
644041687753796294274968748889682955627391774471184472 9 9 2 9 4 2 4 7 3 1 1 1 3 2 4 7 3 7 0 8 9 6 8. B. 0 2 9 4 2 6 6 2 9 5 3 2 5 3 5 4 9 4 3 5 6 8 6 0 0 2 9 2 1 9 V
H C
T 333223221111011212121013221421841311251132514222212224 N
C A
E H
F E
D V
AO S
EH
)
D
'E
(
M E
J Z
1 I
7618539e4e423913265e22728651768822329eS714168287185458 S
1 111 21l l
32111111l22 2122222 22111 l I 2111 11212 11 0
M A
L F
=
A T
5 A
5 D
EH H
C C
N I
I T
(
C 675389085597398987317080021704687796743641493837342080 E
T PS N
83ee9411212131113242t231311212521201221121232123232231 5M2 E
NA8 I
IL E
FR H
T O
NET M
WUI EB A
L mTE F
N i
CLE LG VADFM O
EOE N
T O
TTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTT 6sS I
EEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE 8a T
EEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE 9DR A
HHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHH 1TO C
S55S5S5555S5S55SS55S5SSS5S5S55SSSS5SSS55SSSSSSSSSSS5SS SF O
EEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE TI L
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBEBEBBBBBBBBEBB Ut UuUUUUUUUUUUUUUUuUUUt UUUUUUUUUUUUUUUUUUUUUUUUUUUUUUU CL N
T7TTTTTTTTTTTTTTTTTTTTYTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTT F
A D
L F
V e
tt e
D DBaDDBDaODaDaDBDDaea aD B o
DDDDD ADD OD D
B O
BODDDO C
LttLLttttLtLtLtLLtttTtLTtTTtTLLLLLTtLLTtLTLTtTtTt tL tL L tS O
O0oOO0oooOoO0OoOOoooOoOOoOOoOOOOOOOoOOOoOOOOoOoO0oOoOO L
CCCCCCCCCCCCCCCCCCCCHCCHCHHCNCCCCCHCCCNCCHCHCHCNCCCCCC 09D 6784012345566791133577788980111233444566677889940e1223 LL 7778222222222223333333333344444444444444444444455S5555 O
C MO 333344444444444444444444444444444444444444444444444444 D
222222222222222222222222222222222222222222222222222222 RO T
AR E
N E
222222222222222222222222222222222222222222222222222222 G
N A
ETS li ll 5
l i!l!!l!
- i3i)i
,i l
I!!
l'
- ll!);jl
73 68 E
9 G
1 A
T L
8740700882!8030976723697927540137095623228147375291052 O
O 8 6. D.0 5 4 0 2 8 2. !. 2 5 4 3 8 1 3 4 8 7 4 1 7 7 2 3 9 9 6 6 3 2 1 1 0 2 4 3 7 8 7 8 0 0 3 1 9 7 4 6 2 2 5 V
N 401212211111211222311323323133223294121142143123240222 C
T 1
R C
A E
tI F
E D
V AD S
EN
)
O E
8 W
E J'l Z
379541442431050877991711179e5726e79041883462S57e283401 I
S 22 2223 132242 111 2
2111 l
121l1131 1221I1 l 11 1 21 0
N AL F
A T
S A
S B
EH N
C O
H I
I T
I C
054886164849880040379618683348194616819908387507751055 E
T PS H
235I13103031142313121323313231333I33210213130114403111 SN2 G
NA8 I
IL E
FR H
T O
NET W
E S T.
A t
L L
H TE F
N N
tCLE LG TA t
D r
DFA t
EOE P
T O
TTTTTTTTTTTTT TTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTT 6sS I
EEEEEEEEEEEEE EEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE 0t T
EEEEEEEEEEEEEPEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE 9IR A
HHHHHHHHHHHHHSH3HHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHH 1TO C
5S5555S555555T555555555555S5555555S5555S555S5S555S5S55
- F O
EEEEEEEEEEEEE EEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE BBBBBBBBBBBBB8BBBBBBBBBBBBBBBBBBBBEBBBBBBBBBtEBBBEBBBB VI L
CL UUUUUUUUUUUUUeUUUUUUUL UUUUUUUUUUUUUUUUUUUUUUuUUUUUUUUU N
TTTTTTTTTTTTT3TTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTT F
A D
L F
VRu 9N DDaDD DD DDD DDDDDDDDDDDDDDDDDDDD DD DD D
DDDDDOD DDD L
C LLtLLTTLLTLLLTLLLLLLLLLLLLLLLLLLLLTLLTL LTLTLL L L LLL TL t L S
O OOoOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOoO L
CCCCCHHCCHCCCHCCCCCCCCCCCCCCCCCCCCMCCNCCHCHCCCCCCCNCCC 89#
34456777788890001122334456677S899011122233445567893134 tL 555555555555566666666666666666646777777777777777778222 O
C MO 444444444444444444444444444444444444444444444444444555 B
222222222222222222222222222222222222222222222222222222 RO T
A R
EN E
222222222222222222222222222222222222222222222222222222 G
lra E
T S
=
e*
4 3
69 E
9 G
1 AT L
5 O
491639203240411591573589565575491141074275752740554893 V
329747666243684155917268518112797846009496874541 088761 H
C T
012131111222332224212314243252332222261182112314202142 R
C A
E M
F E
D r
A
^
DS EH 1
s D
2 E
1 N
2 3
2 39293392642574921232622443448015349783729551 924515!21 7 1
I S
41 11 112 11 1222 12112 11 1111 122 2
12112123!331 0
IM L
F 3
7
)
2 S
~
C EH N
C t
D I
T E
C 425922032080738286887889519438438237905688685792588451 E
T PS H
123122323111212I2241223322S32322422182313231031I513033 SW2 G
NA8 I
IL E
FR H
T 0
NE7 N
U M CLELG VA s
D M
DFA EOE N
T O
TTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTT TTtTT 6GS I
EEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE EEEEE 6N T
EEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEPEEEEE 9IR A
HHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHSHHHHH 1TO C
5S5SS55SS55SSSS5S5SS5555S55SS5SSSSSSS5SSSSSSSSSSTSSSSS 2F O
EEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE EEEEE TI L
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBSBBBDBBBBBBBBBBBBB0BCBBB UUUUUUUUUUUUUUUUUUt UUUUUUUUUUULUUUUUUUUUUUUUUUUURUUUUU CL M
TTTTTTTTTTTTTTTTTT7TTTTTTTTTTTTTTTTTTTTTTTTTTTTT3TTTTT F
A O
L F
TWam r
DBDDBDBBD D D D DDO BD B0D BD DD BDDDD DDD D
DDO ODDDD u
C LtLLtLttLTLTLTLTLLLTttTt1LTtLTLLTtLLLLTLt LTLTtt tTt t Lt L S
O OoOOOOooOOOOOOOOOOOO0oO00OOOOOOOO0OOOOOOoOOOOoooOooOoO L
CCCCCCCCCHCHCHCHCCCHCCHCCCHCCHCCHCCCCCHCCCHCHCCCHCCCCC 49#
668123456778899881122344456678890012334445667789080222 t
222333333333333444444444444444445555555555555555666666 LO C
N O
555555555555555555555555555555555555555555555555555555 D
222222222222222222222222222222222222222222222222222222 RO T
A D
E M
E 222222222222222222222222222222222222222222222222222222 G
M A
E TS 1
- d il' i
3
!4 lli lj;il)
I i'
SUPTtARY OF CY 1986 EDDY CURRENT INSPECTION DAT3 0:10 WEDHESDAY, MARCH 5, 1986 39 LI; TING OF CLL TUBE FLAWS FOR STEAM GEHE ATOR 82 STEAM GENERATOR ROM COLL 998 LOC FLAW LOCATION FLAW HEIGHT IIHCHES)
FLAN SIZE 1%)
DEFECT VOLTAGE 2
25 63 COLD TUBESHEET 0.9 29 8.99 2
25 63 COLD TUBESHEET 2.7 14 1.66 2
25 64 COLD TUBESHEET 3.1 37 1.33 2
25 64 COLO TUBESHEET 3.9 11 4.49 2
25 65 COLD TUBESHEET 5.0 21 1.09 2
25 65 COLD TUBESHEET 5.7 4
3.39 2
25 66 COLD TUBE SHE ET 1.9 28 2.88 2
25 66 COLD TUBESHEET 3.2 8
4.07 2
25 67 COLD TUBE 5HEET 1.7 11 3.67 2
25 67 COLD TUBESHEET 3.3 9
5.45 2
25 68 COLD TUBESHEET 1.4 16 3.12 2
25 68 COLD TUBESHEET 3.3 17 2.49 i
2 25 69 COLD TUBESHEET 2.3 37 1.32 2
25 69 COLD TUBESHEET 3.1 8
2.12 2
25 70 COLD TUBESHEET
!.4 4
2.80 2
25 70 COLD TUBESHEET 3.1 11 2.43 2
25 71 HOT TUBESHEET 4.1 7
2.02 2
25 71 COLD TUBESHEET 3.9 26 2.00 2
25 71 COLD TUBESHEET 1.6 19 2,08 2
25 72 COLD TUBESHEET
.1.6 13 1.35 2
25 72 COLD TUBESHEET 2.5 5
1.68 2
25 73 HOT TUBESHEET 0.9 17 15.32 2
25 73 COLD TUBESHEET 1.0 23 4.18 2
25 74 HOT TUBESHEET 1.0 38 13.93 2
25 74 COLD TUBESHEE T 2.8 9
1.66 2
25 75 HOT TUBESHEET 1.2 24 5.36 2
25 75 COLD TUBESHEET 0.5 32 6.39 2
25 76 NOT TUBESHEET 4.9 35 8.61 2
25 76 COLD TUBESHEET 0.6 31 6.71 2
25 77 COLD TUBESHEET 3.8 25 5.59 2
25 78 COLD TUBESHEET 4.4 38 5.51 4
2 25 79 COLD TUBESHEET 3.5 to 3.54 2
25 83 HOT 3RD TSP 12.5 4
2.23 2
25 84 HOT TUBE SHEET 2.0 14 2.07 2
25 84 HOT IST TSP 15.9 26 0.71 I
2 25 84 HOT 2HD TSP 6.5 10 1.00 2
26 23 COLD TUBESHEET 1.0 4
2.30 2
26 24 COLD TUBESHEET 3.5 4
4.34 4
2 26 25 COLD TUBESHEET 1.6 4
2.12 2
26 26 COLO TUBESHEET 3.0 2
1.76 2
~
26 31 COLD TUBESHEET 2.9 5
2.23 2
26 34 COLD TUBESHEET 2.1 4
3.20 3
2 26 35 COLD TUBESHEET 1.7 5
4.61 2
26 35 COLD TUBESHEET 3.2 1.35 i
2 26 36 COLD TUBESHEET 3.3 16 1.58 1
2 26 37 COLD TUBESHEET 2.8 11 1.82 2
26 38 HOT TUBESHEET 0.8 6
3.88 2
26 38 COLD TUBESHEET 2.6 9
2.03 2
26 40 HOT TUBESHEET
!.0 14 2.27 2
26 40 COLD TUBESHEET 2.7 23 0.89 2
26 41 HOT TUBESHEET 4.8 25 2.44 l
2 26 41 COLD TUDESHEET 2.3 25 0.91 2
26 42 HOT TUBESHEET 0.8 15 1.75 2
26 42 COLD TUBESHEET 2.6 14 2.34 4
e
SuretARY OF CT 1986 EDDT CURRENT INSPECTION CATA 0:19 WEDHESDAY. PtARCH 5. 1986 40 LISTIU3 DF ALL TUBE FLAWS FOR STEAH GEHCATOR 82 STEAN GENERATDR ROW COLUNN LOC FLAM LOCATIDH FLAN HEIGHT IINCHES)
FLAN SIZE 1%)
DEFECT VOLTAGE 2
26 42 COLD TUSESHEET 3.5 4
2.62 2
26 43 COLD TUBESHEET 2.4 4
1.59 2
26 44 COLD TUBESHEET 2.5 5
3.27 2
26 45 HOT TUBESHEET 0.8 13 2.IA 2
26 45 COLD TUBESHEET 2.5 5
3.64 2
26 46 HOT TUBESHEET 0.7 19 2.08 2
26 46 COLD TUBESHEET 2.4 15 4.48 2
26 47 HOT TUBESHEET 0.5 18 1.45 26 48 HOT TUBESHEET 1.0 19 2.78 2
26 48 COLD TUBESHEET 2.2 13 3.77 2
26 49 COLD TUBESHEET 2.8 13 1.00 2
26 50 HOT TUDESHEET 0.6 16 2.34 2
26 50 hcl TUBESHEET 11.2
~
48 2.35
~
2 26 50 C0l O TUBESHEET 1.9 13
' 3.31 2
26 51 COLD TUEESHEET 2.1 7
2.13 2
26 52 HOT TUBESHEET 1.1 17 0.74 2
26 53 COLD TUBESHEET 2.0 26 4.31 2
26 54 HOT TUBESHEET
- 0. 7 -
2J 1.59 2
26 54 COLc TUBESHEET 1.9 20 4.21 2
26 54 COLD TUBES 6EET 2.9 11 0.99 2
26 55 HOT TUBESHEET 0.4 15 2.41 2
26 55 Cuto TUBE SHEET 3.8 8
4.29 2
26 55 t COLD TUPE5 MEET 2.9 6s
^
1.70, 1
2 26 56 HOT Tue2 SHEET 3.8 12 3.03 2
26 56 COLD TUBEShtET 1.8 13 3.12 2
26 58 HOT TUB! SHEET 0.6 12 2.40 2
26 58 COLD TUDESHEET 1.8 10 2.84 2
26 59 COLD TUBESHEET 1.8 12 2.86 2
26 60 COLD TUBESHEET 1.7 20 4.47 2
26 60 COLD TUBESHEET 2.9 13-2.19 2
26 61 COLD TUBESHEET 1.7 19 3.02 2
26 61 COLD TUBESHEET 3.1 15 3.15 2
26 62 COLD TUBE SHE(T 0.4 17 2.21 2
26 62 COLD TUBE S!iE E T 1.7 20 4.48 2
26 63 CCLD TucESHEET 0.5 45 1.04 2
26 63 COLD TUBESHEET 2.8 14 1.40 2
26 64 COLO TUBESHEET 1.8 24 3.92 2
26 64 COLD TUBESHEET 3.3 10 1.65 2
26 65 COLD TUBESHEET 2.2 26 4.31 2
26 65 COLD TUEESHEET 3.2 17 2.02 2
26 66
' COLD TUBESHEET 1.9 26 5.60 2
26 66 COLD TUBESHEET 3.3 21 4.15 2
26 67 COLD TUBESHEET 3.6 17 4.21 2
26 68 COLD TUBESHEET 3.6 18 3.94 2
26 68 COLD TUBESHEE T 3.4 1
2.28 2.
26 49 COLD TUBESHEET 2.6 18 2.26 2
?6 69 COLD TUBESHEET 3.3 17 1.45 2
26 70 COLD TUBESHEET 1.7 36 1.97 2
26 70 COLD TUBESHEET 2.9 20 1.72 2
26 71 COLD lueESHEET 1.1 19 1.69 2
26 71 COLD TUDESHEET 2.6 19 1.20 2
26 72 COLD TUDESHEET 0.7 22 1.28 2
26 72 COLD TUBESHEET 3.3 6
1.37 2
26 73 COLD TUEESHEET 1.0 28 8.16
StM1 ART OF CY 1986 ED0Y CtRRENT 3HSPECTIDH COTA 0:10 WEDIESDAY, MARCH 5,1986 Cl LISTII:G CF CLL TUBE FLAWS FOR STEAN GENE!ATOR 52 STEAN GENERATOR ROM COLUNH LDC FLAW LOCATIDH FLAW HEIGHT EINCHESI FLAW SIZE (%I DEFECT VOLTALE 2
26 73 COLD TUBESHEET 3.2 6
1.80 2
26 75 HOT TUBESHEET 1.0 30 10.26 2
26 75 COLD TUBESHEET 2.7 29 0.65 2
26 76 HOT TUBESHEET 0.7 30 8.22 2
26 76 COLO TUBESHEET 0.6 30 5.90 2
26 77 COLD TUBESHEET 4.6 17 4.89 2
26 78 COLD TUBESHEET 0.5 27 3.47 2
27 14 HOT TUBESHEET 1.6 9
3.15 2
27 23 COLD TUBESHEET 0.3 32 1.96
'2 27 24 COLD TUBESHEET 0.9 25 1.58 2
27 25 COLD TUBESHEET 1.5 le 2.66 2
27 31 COLD TUBESHEET 2.4 19 1.01 2
27 32 COLD TUBESHEET 4.8 19 1.28 2
27 33 COLD TUBESHEET 2.3 2
4.54 2
27 36 COLD TUBE SHEET 2.7 18 1.74 2
27 37 COLD TUBESHEET 2.8 13 2.51 2
27 38 HOT TUBESHEET 8.7 16 1.39 2
27 39 COLD TUBESHEET 0.9 26 1.30 2
27 39 COLD TUBESHEET 2.6 16 4.06 2
27 40 HOT TUBESHEET 3.1 27 2.43 2
27 40 COLD TUBESHEET 3.2 14 1.20 2
27 41 COLD TUBESHEET 2.8 16 1.69 2
27 42 HOT TUBESHEET O.9 15 2.50 2
27 42 COLD TUBESHEET 3.7 8
1.97 2
27 43 HOT TUBESHEET 0.8 27 1.33 2
27 43 COLD TUBESHEET 2.7 7
2.08 2
27 44 HOT TUBESHEET 0.6 13 1.33 2
27 45 HOT TUBESHEET 0.7 17 2.76 2
27 45 COLD TUBESHEET 2.6 12 2.98 2
27 46 HOT TUBESHEET 0.7 23 1.99 2
27 46 COLD TUEESHEET 2.5 16 3.85 2
27 47 HOT TUBESHEET O.7 18 2.39 2
27 47 COLD TUEESHEET 2.5 2.91 2
27 48 HOT TUBESHEET 5.5 17 1.84 2
27 48 COLD TUBESHEET 2.1 7
3.84 2
27 50 COLD TUBESHEET 2.1 4
3.53 2
27 51 COLD TUBESHEET 3.3 4
1.53 2
27 52 HOT TUBESHEET 0.5 20 0.70 2
27 52 COLD TUBESHEET 1.7 16 2.46 2
27 53 COLD TUBESHEET 0.7 30 1.84 2
27 53 COLD TUBESHEET 1.8 21 3.18 2
27 54 HOT TUBESHEET 8.8 12 1.90 2
27 54 COLD TUBESHEET 2.8 5
1.04 2
27 55 COLO TUBESHEET 2.3 25 0.68 2
27 56 COLD TUBESHEET
!.7 11 2.77 2
27 57 HOT 4TH AVB 0.0 18 1.02 2
27 57 COLD TUBESHEET 2.0 17 2.12 2
27 58 COLD TUBESHEET 2.0 22 3.06 2
27 50 COLD TUBESHEET 3.1 9
8.94 2
27 59 CotD TUBESHEET 2.4 29 1.04 2
27 60 001D TUDESHEET 2.5 26 0.69 2
27 60 COLD TUBESHEET 3.1 22 2.66 2
27 COLD TUBESHEET 1.6 19 5.23 2
27 62 COLD TUBESHEET 1.3 20 6.05 J
SUtttART OF CT 1986 EDOT CtAPRENT INSPECTION CATA 0:19 WEDt3SDAT, itARCH 5,1986 42 LISTIt.'G OF ALL TUBE FLAWS FOR STEAN GENE!ATOR 82 STEAM GENERATOR 90W COLUNH LOC FLAW LOCATIDH FLAW HEIGHT IIHCHES)
FLAW SIZE EXl DEFECT VOLTAGE 2
27 63 COLD TUBESHEET 1.8 23 3.97 2
27 63 COLD TUBESHEET 2.5 12 1.66 2
27 64 COLD TUBESHEET 2.0 27 5.45 2
27 64 COLD TUDESHEET 2.6 17 1.00 2
27 65 COLD TUBESHEET 2.1 23 4.67 2
27 65 COLD TUBESHEET 3.0 11 2.23 2
27 66 COLD
.TUBESHEET 3.4 23 3.28 2
27 67 COLD TUBE SHEE T 3.2 14 1.95 2
27 68 Col 0 TUBESHEET 1.4 15 2.64 2
27 68 COLD TUBESHEET 3.5 4
2.46 2
27 69 COLD TUBESHEET 2.6 12 2.58 2
27 70 COLD TUBESHEET 2.8 27 1.15 2
27 70 COLD TUBESHEET 3.1 12 1.42 2
27 71 COLD TUBESHEET 1.2 25 1.61 2
27 71 COLD TUBE SHEE T 2.9 16 1.75 2
27 72 COLD TUBESHEET 1.3 24 4.32 2
27 72 COLD TUBESHEET 2.2 13 1.66 2
27 73 COLD TUBESHEET 0.8 17 7.09 2
27 74 HOT TUBESHEET 3.1 28 17.42 2
27 74 COLD TUBESHEET 0.2 19 5.32 2
27 75 COLD TUBESHEET 0.6 17 6.89 2
27 76 COLD TUBESHEET 0.3 14 3.06 2
27 84 HOT 3RD TSP 3.6 8
0.92 2
27 84 HOT 3RD TSP 43.2 9
2.08 2
28 24 COLD TUBESHEET 0.5 25 2.82 2
28.
24 COLD TUBESHEET 1.0 9
0.84 2
28 25 COLD TUBESHEET 1.2 19 2.73 2
28 26 COLD TUBESHEET 2.1 12 0.91 2
28 27 COLD TUBESHEET 2.1 15 1.25 2
28 28 COLD TUBESHEET 3.3 13 1.51 2
28 31 COLD TUBESHEET 3.7 5
2.26 2
28 32 COLO TUBESHEET 3.7 17 1.27 2
28 35 COLD TUBESHEET 1.8 7
4.24 2
28 37 COLD TUBESHEET 1.5 2
3.93 2
28 38 COLD 7 '.E E SHE E T
!.5 5
3.75 2
28 39 COLD TUBESMEET 2.3 9
2.65 2
28 40 COLD TUDESHEET 2.3 8
2.12 2
28 41 COLD TUBESHEET 4.0 7
1.91 2
28 42 HOT TUBESHEET 1.0 17 2.13 2
28 42
- COLD TUBESHEET 3.9 17 1.24 2
28 43 HOT TUBESHEET 0.7 17 1.30 2
28 44 HOT TUBESHEtt 0.6 13 1.84 2
28 44 C0tD TUBESHEET 1.3 26 0.64 2
28 44 COLD TUBESHEET 2.5 19 3.23 2
28 45 COLD TUBESHEET 2.4 14 2.37 2
28 46 HOT TUBESHEET 0.7 16 1.18 2
28 46 COLD TUDESHEET 2.3 17 4.42 2
28 47 Cot 0 TUBESHEET 2.3 II 4.17 2
28 48 COLD TUDESHEET 2.2 5
3.64 2
28 49 C01D TUDESHEET 2.0 14 2.02 2
28 50 COLD TUDESHEET 2.1 7
1.86 2
28 51 CotD TUDESHEET 2.3 2
2.!!
2 28 52 COLD TUDESHEET 0.7 23 1 29 2
28 52 COLD TucESHEET 2.1 14 2.00
SUMMART OF CT 1986 EDDT CURRENT INSPECTION SATA 0:10 MEDt'ISDAT. MARC 3 5.1986 43 LISTIt8G DF ALL TUBE FL AWS FOR STEAN GENERATOR 82 STEAM GENERATOR ROW COLUNN LOC FLAW LOCATIDH FLAW HEIGHT IIHCHESI FLAN SIZE 1%I DEFECT VOLTAGE 2
28 53 COLD TUBESHEET 1.7 18 2.89 2
28 54 COLD TueE SHE E T 1.7 17 4.84 2
28 55 COLD TUDESHEET 1.8 8
3.23 2
28 56 HOT TUBESHEET 0.5 14 1.28 2
28 56 HOT 2HD TSP 10.0 37 2.27 2
28 56 HOT 2HD TSP 14.5 24 1.42 2
28 56 COLD TUBESHEET 1.8 9
3.77 2
28 57 COLD TUBESHEET 1.8 12 3.09 2
28 58 HOT TUBESHEET 0.8 20 1.03 2
28 58 COLD TUBE 5HEET 2.4 20 2.67 2
28 59 COLD TUBESHEET 1.4 le 3.99 2
28 60 HOT TUBESHEET 0.4 16 1.38 2
28 60 COLD TUBESHEET 1.6 22 4.65 2
28 60 COLD TUBESHEET 2.8 21 2.76 2
28 61 HOT 2HD TSP 2.7 21 1.02 2
28 61 COLD TUBESHEET 1.5 26 '
2.90
+
2 28 61 COLU TUBESHEET 3.6 2
2.93 2
28 62 COLD TUBESHEET 1.7 26 4.16 2
28 62 COLD TUBESHEET 3.7 1
3.43 2
28 63 COLD TUBE SHEET 1.8 30 3.76 2
28 63 COLD TUBESHEET 2.4 20 3.56 2
28 64 COLD TUBESHEET 2.0 17 4.20 2
28 64 COLD TUBESHEET 3.3 16 1.22 2
28 65 COLD TUBESHEET 3.4 21 1.08 2
28 66 COLD TUBESHEET 2.5 30 2.73 2
28 66 COLD TUBESHEET 3.5 22 1.40 2
28 67 COLD TUBESHEET 1.3 35 0.90 2
28 67 COLD TUBESHEET 3.5 15 2.41 2
28 68 COLD TUBESHEET 3.0 27 0.98 2
28 68 COLD TUBESHEET 3.2 17 0.90 2
28 69 COLD TUBESHEET 1.6 21 2.42 2
28 69 COLD TUBESHEET 2.5 10 3.57 2
28 70 COLD TUBE SHEE T 0.7 42 1.04 2
28 70 COLD TUBESHEET
!.9 7
1.74 2
28 71 COLD TUBESHEET 1.3 30 5.25 2
28 71 COLD TUBESHEET 2.9 11 1.34 2
28 72 COLD TUDESHEET 1.0 21 6.04 2
28 73 HOT TUBESHEET
!.0 13 2.29 2
28 73 COLD TUBESHEET 4.4 34 5.40 2
28 73 COLD TUBLSHEET 1.4 18 1.97 2
28 74 HOT TUBESHEET 0.8 41 26.18 2
28 74 COLD TUBESHEET 0.2 39 13.19 2
28 75 HOT TUBESHEET 3.0 9
0.78 2
28 75 COLD TUBESHEET 0.5 30 6.77 2
28 77 HOT TUBESl;EE T 3.6 23 0.70 2
28 83 HOT 3R0 TSP 9.1 39 0.97 2
28 83 HOT 3RD TSP
!!.4 19 1.82 2
28 84 HOT 3RD TSP-3.7 42 1.00 2
28 84 HOT 3RD TSP 16.4 3
1.88 2
28 87 HOT 3RD TSP 7.6 18 1.05 2
28 87 HOT IST AVB 0.0 17 1.83 2
28 88 HOT 3RD AVB 0.0 12 2.47 2
29 25 COLD TUBESHEET 1.2 5
2.15 2
29 28 Cold TUBESHEET 3.3 1,32 i
St#9tARY OF CY 1986 EDOT CURRENT INSPECTION DATA 0:19 WEDt4ESDAY. MARCH 5.1986 44 LISTING OF ALL TUBE FLAWS FOR STEAN GENE ATOR 82 STEAM GENERATOR ROH COLUMM LDC FLAW LOCATION FLAW HEIGHT IINCHESI FLAW SIZE (%)
DEFECT VOLTAGE 2
29 31 COLD TUBESHEET 9.1 7
2.02 2
29 34 COLD TUBESHEET 3.3 12 1.74 2
29 35 COLD TUBESHEET 3.1 13 1.D6 2
29 37 COLD TUBESHEET 3.5 11 1.56 2
29 39 HOT TUBESHEET 0.7 27 1.20 2
29 40 COLO TUBESHEET 3.1 6
4.05 2
29 41 COLD TUBE SHEE T 3.7 11 2.44 2
29 42 C010 TUBESHEET 2.0 14 1.65 2
29 43 HOT TUBESHEET 0.6 17 1.17 2
29 43 COLD TUBESHEET 2.0 8
1.83 2
29 44 HOT TUBESHEET 4.7 35 1.21 2
29 44 COLD TUBESHEET 2.9 13 1.22 2
29 45 COLD TUBESHEET 2.2 11 3.95 2
29 46 COLD TUBESHEET 2.1 5
2.42 2
29 47 COLD TUBESHEET 2.3 7
2.99 2
29 48 COLD TUBESHEET 2.2 8
2.28 2
29 49 COLD TUBESHEET 3.8 19 2.17 2
29 50 COLD TUBESHEET 3.8 4
2.23 2
29 51 C010 TUBESHEET 1.8 14 3.61 2
29 52 COLD TUBESHEET 1.7 17 4.30 2
29 52 COLD TUBESHEET 3.0 10 1.08 2
29 S3 HOT TUBESHEET 0.9 12 2.80 2
29 53 COLD TUBESHEET 0.6 28 1.85 2
29 53 CotD TUBESHEET 2.0 17 4.67 2
29 54 COLD TUBESHEET 1.9 19 4.65 2
29 55 HOT 2HD TSP 12.3 10 1.16 2
29 55 COLD TUBESHEET 3.8 18 4.36 2
29 55 COLD TUBESHEET 2.6 6
1.33 2
29 56 HOT TUBESHEET 0.5 21 0.91 2
29 56 COLD TUBESHEET 1.8 13 3.59 2
29 56 COLD TUBESHEET 3.7 10 1.62 2
29 57 COLD TJoESHEET 1.8 22 3.15 2
29 M8 COLD TUBESHEET 3.7 20 3.04 2
29 59 COLD TUBESHEET 1.9 22 2.18 2
29 60 COLD TUBESHEET 2.4 26 0.86 2
29 60 Cot 0 TUBESHEET 3.6 8
1.84 2
29 61 COLD TUBE SHEET 1.8 29 4.90 2
29 61 COLD IUBESHEET 2.6 16 2.60 2
29 62 COLD TUBESHEET 2.6 17 2.72 2
29 63 C010 TUBESHEET 1.8 28 6.59 2
29 63 C01D TUBESHEET 2.5 11 4.19 2
29 64 COLD TUBESHEET 1.9 26 6.69 2
29 64 COLD TUDESHEE T 2.8 18 4.45 2
29 65 COLD TUBESHEET 1.9 22 4.57 2
29 65 COLD TUBESHEET 3.0 15 2.80 2
29 66 COLD TUbESHEET 1.8 24 3.98 2
29 66 CotD TUSE SHEET 3.4 15 1.78 2
29 67 HOT TUDESHEET 3.5 11 1.51 2
29 67 HOT 3RD TSP 13.4 15 1.23 2
29 67 COLD TUBESHEET 3.4 22 3.40 2
29 68 COLD TUBESHEET 1.3 33 1.48 2
29 68 CO* n-TUDESHEET 3.4 16 1.02 2
29 69 COLD TUBESHEET 1.6 23 2.59 2
29 69 COLO TUDESHEET 2.2 20 3.51
SUNHART OF CV IC86 EDDY CURRENT ItiSPECTION EATA 0:10 WEDHESOAY. HARCH 5: 1986 (5
LISTING OF ALL TUCE '. a WS FOR STEAN CENERATLat C2 STEAN GENERATOR RDW COLUNH LDC FLAW LDCATIDH TiaW HEIGHT IINCHESI FLAW SIZE EXI DEFECT VDLTAGE 2
29 70 HOT 4TH TSP 0.8 71 1.33 2
29 70 COLD TUBESHEET I.6 28 5.20 2
29 71 HOT TUBESHEET 3.7 14 1.41 2
29 71 L08 5 TUBESHEET 1.2 29 4.78 2
29 72 HOT TUDESHEET 3.7 7
2.47 2
29 72 COLD TUBESHEET 1.0 25 6.90 2
29 72 COLD TUBESHEET 1.9 10 1.51 2
29 73 COLD TUBESHEET 0.8 19 5.68 2
29 74 COLD TUBESHEET 0.5 20 7.18 2
29 75 COLD TUBESHEET 0.4 6
4.13 2
29 78 HOT TUBESHEET 4.0 20 1.44 2
29 84 HOT 3RD TSP 15.2 30 2.79 2
29 85 HOT 3RD TSP 0.9 29 2.23 2
29 88 HOT 2ND AVB 0.0 7
3.12 2
29 89 HOT 2HD AVB 0.0 6
3.77 2
30 27 COLD TUBESHEET 2.4 14 1.15 2
30 29 COLD TUBESHEET 3.2 3
1.77 2
30 32 COLD TUBE SHEET 3.6 15 2.38 2
30 32 COLD TUBESHEET 4.8 11 1.17 2
30 35 COLD TUBESHEET 1.3 10 1.52 2
30 36 COLD TUBE SHE ET 2.6 14 1.58 2
30 37 COLD TUBESHEET 2.5 to 0.88 2
30 38 COLD TUBESHEET 4.0 19 1.53 2
30 40 COLD TUBESHEET 1.0 8
4.03 2
30 41 COLD TUBESHEET 2.1 16 1.21 2
30 41 COLD TUBESHEET 4.0 2
1.87 2
30 42 COLD TUBESHEET 1.0 4
3.57 2
30 42 COLD TUDE SHEE T 2.0 10 1.73 2
30 43 COLD TUBESHEET 2.4 26 1.08 2
30 44 HOT TUBESHEET 0.7 17 1.89 2
30 44 COLD TUBESHEET 2.2 9
2.08 2
30 45 COLD TUBESHEET 2.3 7
2.50 2
30 46 COLD TUBESHEET 2.2 13 2.64 2
30 47 COLD TUeESHEET 2.3 18 4.!8 2
30 48 COLD TUBESHEET 2.2 21 2.12 2
30 48 COLD TUBESHEET 3.2 5
1.08 2
30 49 COLD TUBESHEET 1.9 19 1.88 2
30 50 COLD TUBESHEET 1.8 14 2.39 2
30 51 COLD TUDESHEET 0.6 33 1.23 2
30 51 COLD TUBESHEET 1.9 11 3.44 2
30 52 COLD TUBESHEET 2.0 11 3.06 2
30 53 HOT TUBESHEET 0.7 8
3.19 2
30 53 COLD TUDESHEET 1.9 20 4.80 2
30 54 COLD TUBESHEET 1.8 26 3.26 2
30 55 COLD TUBESHEET 1.7 15 4.17 2
30 56 COLD TUBESHEET 1.6 15 3.20 2
30 56 COLD TUBESHEET 3.7 9
2.48 2
30 57 COLD TUBESHEET 1.7 22 3.43 2
30 57 COLD TUBESHEET 3.9 11 2.52 2
30 58 COLD TUBESHEET I.8 22 3.64 2
30 59 COLD TUBESHEET 1.9 25 4.07 2
30 60 COLD TUBESHEET 1.7 23 3.94 2
?2 61 COLD TUBESHEET 0.5 24 1.81 2
30 01 COLD TUBESHEET 1.6 17 3.31
SLRt1ARY OF CY 1986 EDDY CURRENT INSPECTIDH DATA 0:19 WEDHISDAY.11 ARCH 5.1986 46 LISTIt:5 0F ALL TUEE FLAWS
=
FOR STEAN GENE AT0tt 82 STEAN GENERATOR ROW COLUMN LCC FLAH LDCATIDH FLAW HEIGHT IINCHESI FLAN SIZE IXl DEFECT VOLTAGE 2
30 63 COLD TUBESHEET 1.7 32 5.89 2
30 63 COLD TUBESHEET 2.6 7
1.01 2
30 64 COLD TUBESHEET 1.6 19 3.78 2
30 e5 COLO TUBESHEET 1.5 23 2.74 2
30 65 COLD TUBESHEET 2.7 17 3.48 2
30 66 COLD TUBESHEET 1.6 28 1.93 2
30 66 Col D TUBE SHE ET 2.9 4.05 2
30 67 COLO TUBESHLET 2.7 26 2.51 2
30 68 COLD TUBESHEET 1.5 30 2.34
[
2 30 69 COLD TUBESHEET 2.2 34 2.88 l
2 30 69 EOLD TUBESHEET 3.6 to 0.84 I
2 30 70 COLD TUBESHEET 1.3 29 7.54
(
2 30 71 COLD TUBESHEET 1.2 26 5.17 l
2 30 71 COLD TUBESHEET 2.5 12 1.70 2
30 73 COLD TUBESHEET 0.3 25 6.95-l 2
30 73 COLD TUBESHEET 1.9 19 0.86 2
30 74 COLO TUBESHEET 0.0 18 8.58 2
30 75 HOT TUBESHEET 4.0 10 1.62 2
30 77 HOT TUDESHEET 3.9 29 1.14 2
30 82 HOT TUBESHEET 0.7 21 1.66 2
30 83 HOT 3RD TSP 8.3 42 2.01 2
30 88 HOT 3RD AVB 0.0 12 4.72 2
31 29 COLD TUBESHEET 3.2 15 2.20 2
31 31 COLD.
TUBESHEET 2.7 7
1.49 2
31 32 COLD TUBESHEET 4.1 9
2.00 2
31 33 COLD TUBESHEET 1.5 28 0.86 2
31 37 COLD TUBESHEET 2.3 3
2.00 2
31 40 COLD TUBESHEET 2.3 17 2.48 2
31 41 COLD TUBESHEET 2.4 32 1.57 2
31 41 COLD TUBESHEET 3.9 9
1.40 2
31 42 COLD TUBESHEET 0.9 8
4.95 2
31 46 COLD TUEESHEET 2.1 10 4.02 2
31 47 Col 0 TUBESHEET 1.6 11 2.20 2
31 43 COLD TUBESHEET 1.8 24 1.65 2
31 48 COLD TUDESHEET 3.1 13 1.01 2
31 50 COLD TUBESHEET 1.9 29 1.23 2
31 51 COLD TUBESHEET 1.8 9
2.72 2
31 52 COLD TUBE SHE E T 0.5 31 1.23 2
31 52 COLD TUBESHEET 1.5 16 2.65 2
31 53 COLD TUBESHEET 1.9 28 3.10 2
31 54 COLD TUBESHEET
!.8 20 3.13 2
31 54 COLD TUBESHEET 3.3 3
0.94 2
31 55 COLD TUBESHEET 1.8 17 4.43 2
31 56 COLD TUBESHEET 1.6 19 3.33 2
31 56 COLD TUEESHEET 3.8 5
3.07 2
31 57 COLD TUBESHEET 1.8 22 3.26 2
31 57 COLD TUCESHEET 3.8 8
2.86 2
31 58 COLD TUBESHEET 1.6 21 3.68 2
31 59 COLD TUDESHE E T 1.6 25 5.74 2
31 59 COLD TUBE SHE E T 3.7 4
1.57 2
31 60 COID TUBESHEET 3.1 17 1.55 2
31 65 COLD TUBESHEET 1.5 17 2.16 2
31 65 COLD TUEESHEET 3.1 5
1.96 2
!.5 14 1.55
- t#51 ART OF CY 1986 ED0Y CURRENT INSPECTION DATA-0:19 WEDHESDAY. MAPCN 5. 1986 47 LISTING OF ALL TUBE FLAWS FDR STEAM GENERATDR 02 STEAM GENERATOR ROW COLUNH LOC FLAN LOCATIDH FLAW HEIGHT IIHCHES)
FLAW SIZE IX)
DEFECT VOLTAGE 2
31 66 COLD IST TSP 3.1 10 1.98 2
31 67 COLD TUBESHEET 3.0 16 3.78 2
31 68 HOT TUBE SHEET 1.0 20 1.80 2
31 68 C0;D TUBESHEET 0.7 34 1.15 2
31 68 CCLD TUBESHEET 1.2 24 2.58 2
31 68 COLD TUBESHEET 2.6 21 1.23 2.
31 69 HOT TUBESHEET 4.9 9
2.98 2
31 69 COLD TUBESHEET 1.4 23 1.88 2
31 69 COLD TUBESHEET.
2.8 17 1.19 7
31 70
' COLD TUBESHEET 0.8 25 5.59 2
31 70 COLD TUBESHEET 1.8 17 1.59 2
31 71 HOT TUBE SHEE T 0.7 10 4.94 2
31 71 COLD TUBESHEET 0.6 26 4.85 2.
31 71 COLD TUBESHEET 1.7 25 2.08 2
31 72 HOT 2HD TSP 8.7 25 1.41 2
31 72 HOT 2HD TSP
!!.2 14 1.14 2
31 72 COLD TUBESHEET 0.5 42 1.83 2
31 72 COLD TUBESHEET 1.2 42 1.69 2
31 73 COLD TUBESHEET 0.6 16 3.53 2
31 74 COLD TUBf. SHEET 0.0 10 7.05 2
31 80 HOT 3RR AVB 0.0 28 1.37 2
31 82 HOT 3RD AVB 0.0 14 2.53 2
31 82 HOT 4TH Ave 0.0 4
3.15 2
31 83 HOT 2HD AVB 0.0 13 2.82 2
31 84 HOT 3RD TSP 3.5 52 0.41 2
31 84 HOT 3RD TSP 5.0 36 1.29 2
31 84 HOT 2HD AVB 0.0 1
2.78 2
31 86 HOT 2HD AVB 0.0 13 3.49 2
31 86 HOT 3RD AVB 0.0 8
4.09 2-32 2C HOT TUBESHEET 3.6 12 0.92 2
32 29 COLD-TUBESHEET 2.0 7
1.99 2
32 30 COLD TUBESHEET 2.5 5
3.52 2
32 31 CetD TLtESHEET 2.7 22 1.87 2
32 32 Cold TUBESHEET 4.2 15 2.18 2
32 33 COLD TUBESHEET 3.7 11 1.02 t
2 32 34 COLD TUBESHEET 0.9 15 0.85 2
32 37 COLD TUBESHEET 2.2 3
2.32 2
32 38 COLD TUBESHEET 2.2 4
2.27 2
32 42 COLD TUBESHEET 2.3 13 3.85 2
32 48 HOT TUBESHEET 0.5 Il 1.85 2
32 49 COLD TUBESHEET
!.8 14 3.28 2
32 50 COLD TUBESHEET 1.9 13 2.58 2
32 52 COLD TUBESHEET 3.5 10 2.12 2
32 53 COLD TUBESHEET 0.3 36 1.12 2
32 53 COLD TUBE SHEET 1.3 20 3.17 2
32 54 COLD TUBfSHEET 1.4 11 4.07 2
32 55 COLD TUBESHEET 1.6 9
3.95 2
32 56 COLD TUBESHEET 1.5 14 3.31
?
32 56 COLD TUBESHEET 3.8 2
2.49 2
32 57 COLD TUBESHEET 1.5 22 3.55 2
32 58 COLD TUDESHEET 1.5 20 3.98 2
32 59 COLD TUBESHEET 1.5 15 4.77 2
32 59 COLD TUEESHEET 3.5 5
1.14 2
32 60 COLD TUBESHEET 1.6 21 3.06
SUMNARY OF CY 1986 EDDY CURRENT INSPECTIDH CATA 0:10 WEDHESDAY. MARCH 5. 1986 48 LISTING OF ALL TUBE FLAWS FOR STEAN G'ME%ATOR C2 STEAM GENERATDR RDW COLUNH LDC FLAW LDCATIDH FLAW HEIGHT IIHCHES)
FLAW SIZE 1%)
DEFECT VOLTAGE 2
32 61 COtD TUBE 5HEET 1.4 22 3.43 2
32 61 COLD TUBESHEET 2.5 9
2.33 2
32 63 COLD TUBESHEET 1.5 25 4.02 2
32 63 COLD TUBESHEET 2.7 8
3.72 2
32 64
- 10T 3RD TSP 3.8 20 0.89 2
32 64 COLD TUBESHEET
!.3 17 1.79 2
32 65 COLD TUBESHEET 1.4 16 2.46 2
32 65 COLD TUBESHEET 2.4 15 1.22 2
32 66 COLD TUBESHEET 3.2 26 1.79 2
32 66 COLD TUBESHEET 2.0 17 1.47 2
32 67 HOT 3RD TSP 5.4 23 1.16 2
32 67 HOT 3RD TSP 6.5 12 1.62 2
32 67 COLD TUBESHEET 0.9 31 0.97 2
32 67 COLD TUBfSHEET 2.1 19 0.74 2
32 69 COLD TUBESHEET 1.5 26 2.30 2
32 69 COLD TUBESHIET 2.8 19 1.62 2
32 70 COLD TUBESHEET 0.7 27 7.15 2
32 71 COLD TUBESHEET 0.6 37 4.87 2
32 72 COLD TUBE SHEET 0.5 16 1.60 2
32 73 COLD TUBESHEET 0.0 17 5.53 4
32 73 COLD TUBESHEET 0.3 I4 0.55 2
32 74 HOT TUBESHEET 4.6 17 1.56 2
32 79 HOT 3RD AVB 0.0 18 1.32 2
32 82 HOT TUBESHEET 0.8 3
1.24 2
32 02 HOT 3RD AVB 0.0 5
4.06 2
32 83 HOT 2HD AVB 0.0 4
4.84 2
32 84 HOT 3RD TSP 0.9 24 1.29 2
32 35 HOT 3RD AVB 0.0 19 1.50 2
32 86 HOT IST AVB 0.0 5
2.32 2
33 28 COLD TUBESHEET 0.6 13 5.11 2
33 31 COLD TUBESHEET 3.1 23 0.90 2
33 32 COLD TUBESHEET 3.5 8
1.99 2
31 33 COLD TUBESHEET 0.9 8
1.80 2
33 38 HOT TUBESHEET 1.0 19 0.99 2
33 40 COLD TUBE 5HEET 2.1 22 0.64 2
33 42 COLD TUBESHEET 1.8 9
2.79 2
33 43 HOT TUBE %HEET 0.5 26 0.75 2
33 46 HOT TUBESHEET 0.5 17 1.48 2
33 47 COLO TUBESHEET 2.0 6
2.53 2
33 49 COLD TUBESHEET I.5 25 1.50 2
33 49 COLD TUBESHEET 3.0 31 0.55 2
33 51 COLD TUBESHEET 1.7 13.
3.50 2
33 52 COLD TUBESHEET 1.4 36 3.24 2
33 53 COLD TUBESHEET 1.7 23 4.21 2
33 54 HOT 2HD TSP 7.2 5
1.15 2
33 54 COLD TUCESHEET 1.5 21 3.42 2
33 55 COLD TUBESHEET 3.5 32 3.14 2
33 55 COLD TUDESHEET 3.8 9
3.14 2
33 56 COLD TUBESHEET 1.3 19 3.25 2
33 57 CotD TUBESHEET 1.4 22 3.!!
2 33 58 COLC TUBESHEET
!.5 22 2.21 2
33 59 HOT 3RD TSP 10.8 30 1.05 2
33 59 C0tD TUBESHEET 3.3 27 2.91 2
33 60 COLD TUEESHEET 2.3 24 1.88
- - - - - " - - ~
Sutt1 ART OF CT 1986 EDDY CURRENT INSPECTION DATA 0:19 WEDt2SDAT. 39CCH 5.1986 49 LISTIPEi OF ALL TUBE FLAB 5 FOR STEAtt GENERATOR C2 e
STEAM GENERATOR ROW COLUMN
' LDC FLAN LOCATIDH FLAW HEIGHT IINCHESI FLAW SIZE 1%)
DEFECT VOLTAGE 2
33 60 COLD TUBESHEET 3.2 20 2.32 2
33 61 COLD TUBESHEET 1.3 23 2.16 2
33 61 COLD TUBESHEET 2.0 19 3.65 2
33 61 COLD TUBESHEET 3.2 8
2.00 2
33 62 COLD TUBESHEET 1.6 26 2.47 2
33 63 HOT 3RD TSP 3.6 21 0.92 2
33 63 ret D TUBE 5HEET 3.2 28 1.70 2
33 63 TUBESHEET I.6 17 4.24 3
33 64 L-.0 TUBESHEET 1.2 25 2.64 2
33 64 COLD TUBESHEET 2.7 10 3.85 2
33 65 COLD TUBESHEET 2.2 34 1.13 2
33 65 COLD TUBESHEET 2.6 23 1.63 2
33 66 COLD TUBESHEET 1.8 31 2.83 2
33 66 COLD TUBE SHEE T 2.6 17 1.60 2
33 67 COLD TUBESHEET 1.4 45 1.22 2
33 67 COLD TUBESHEET 2.6 9
2.10 2
33 68 COLD TUBESHEET 1.0 27 3.05 2
33 69 COLD TUBESHEET 1.1 39 7.56 2
33 70 COLD TUBESHEET 0.8 33 6.28 2
33 71 HOT TUBE SHEET 4.9 13 0.98 2
33 71 HOT 2HD TSP 1.6 40 1.36 2
33 71 COLD TUBESHEET 0.5 38 1.77 2
33 72 COLD TUBESHEET 0.5 41 1.27 2
33 75 HOT 3RD AVB 0.0 19 0.93 2
4.30 2
33 84 HOT 3RD TSP 4.9 3
1.85 2
33 85 HOT 2HD AVB 0.0 11 3.13 2
33 87 HOT 3RD AVB 0.0 26 2.43 i
2 34 28 COLD TUBE SHEET 0.2 37 1.66 2
34 29 COLD TUBESHEET 0.5 37 2.!!
2 34 31 COLD TUBESHEET 2.5 16 1.19 2
34 32 COLD TUBESHEET 2.8 28 1.02 2
34 33 COLD TUBESHEET 2.1 I4 1.59 2
34 33 COLD TUBE SHEE T 3.3 7
0.91 2
34 34 COLD TUBESHEET 3.8 13 0.97 2
34 35 COLD TUBESHEET I.4 10 1.74 2
34 35 COLD TUBESHEET 3.0 3
2.01 2
34 40 HOT TUBESHEET 0.8 13 2.09 l
2 34 41 COLD TUBESHEET 3.3 31 0.96 i
2 34 43 COLD TUBESHEET 1.7 9
2.25 f
2 34 44 COLD TUBESHEET 2.3 13 1.23 2
34 46 HOT TUBESHEET 0.4 17 1.49 2
34 46 COLD TUBESHEET 3.4 3
2.33 2
34 47 COLD TUBESHEET I.6 11 2.53 2
34 48 COLD TUCESHEET
!.3 2
3.17 2
34 49 COLD TUBESHEET I.3 16 2.68 2
34 50 COLD TUBESHEET 3.3 6
2.24 2
34 52 COLD TUBESHEET-I.4 16 3.22 2
34 53 COLD TUBESHEET 1.5 21 3.29 2
34 54 COLD TUBESHEET 3.2 10 1.83 2
34 55 COLD TUBESHEET
!.3 6
2.34 2
34 56 COLD TUBESHEET 1.4 20 1.81 2
34 56 COLD 10BESHEET 2.2 3
1.17 2
34 57 COLD TUBESHEET 1.5 17 1.88
SUtttART OF CT 1986 EDDT CURRENT 3HSPECTION DATin 0:19 WEDHESDAT MARCH 5. 1986 50 LISTIteG OF ALL TUBE FLAWS FOR STEAN CEHETATOR 02 STEAM GENERATOR ROW COLUMN LOC FLAW LDCATION FLAW HEIGHT IIHCHES)
FLAW SIZE 1%I DEFECT VOLTAGE 2
34 58 COLD TUBESHEET 1.2 34 1.04 2
34 58 COLD TUBESHEET 1.5 22 1.50 2
34 59 COLD TUBE SHEET 1.2 25 1.36 2
34 59 Cold TUBESHEET 2.7 14 2.68 2
34 60 COLD TUBESHEET 2.5 17 1.23 2
34 61 HOT 1UBESHEET 2.5 22 1.12 2
34 61 HOT 3RD TSP 8.5 20 0.89 2
34 61 COLD TUBESHEET 0.4 28 1.60 2
34 60 COLD TUBESHEET 1.6 13 3,14 2
34 62 COLD 1UBESHEET 2.4 8
1.51 2
34 63 COLD TUBESHEET 1.8 23 1.41 2
34 63 CotD TUBESHEET 2.4 10 2.66 2
34 64 COLG TUBESHEET 1.3 29 1.35 2
34 64 COLD TUBESHEET 1.9 25 2.69 2
34 65 Coln TUBESHEET 2.0 25 1.83 2
34 66 COLD TUBESHEET 1.5 28 3.48 2
34 66 CCLD TUBESHEET 2.3 6
1.78 2
34 67 COLD TUBESHEET 1.1 33 2.66 2
34 68 CnLD TUBESHEET 0.6 -
52 1.23 2
34 68 COLD TUBESHEET 1.0 30 2.56 2
34 69 COLD TUBESHEET 0.7 28 4.16 2
34 69 LOLD TUBESHEET 1.3 12 2.01 2
34 70 COID TUBESHEET 0.7 23 1.75 2
34 73 40T IST AVB 0.0 12 3.92 2
34 74 t0LD TUBESHEET 35.6 7
1.61 2
34 81 ROT 3RD TSP 0.6 34 1.24 2
34 84 POT 3RD TSP 6.2 22 0.51 2
35 29 CCLD TUBESHEET 0.2 19 1.40 2
35 32 HOT TUBESHEET 1.4 9
4.90 2
35 33 Is0T TUBESHEET 1.5 22 3.36 2
35 33 COLD TUBESHEET 2.4 17 0.74 2
35 34 COLD TUDESHE ET 2.1 13 1.29 2
35 36 COLO TUBESHEET 3.2 11 0.80 2
35 39 COLD TUBESHEET 2.8 9
1.31 2
35 41 CutD TUBESHEET 3.5 21 1.01 2
35 42 CGLD TUBESHEET 3.1 17 2.15 l
2 35 43 Ne!
TUDESHEET 0.3 17 1.43 2
35 44 HOT TUBESHEET 0.4 15 1.35 2
35 45 COLD TUDESHEET 1.3 18 1.42 2
35 46 COLD TUBESHEET 1.4 11 1.04 2
35 47 HOT TUBESHEET 0.6 27 1,67 2
35 47 COLD
~.UBESHEET 1.3 13 1.85 2
35 51 HOT eUBESHEET 10.6 33 1.68 2
35 51 COLD TUBESHEET 0.6 14 1.21 2
35 51 COLD TUBESHEET 1.1 13 0.96 2
35 52 COLD TUBESHEET 1.0 18 2.58 2
35 53 COLD TUBESHEET 1.6 17 2.04 2
35 54 COLD TUBESHEET 2.5 7
2.31 2
35 55 LOLD IUBESHEET 3.2 10 1.44 2
35 56 COLD TUBESHEET 1.3 18 1.05 2
35 57 COLD TUDESHEET 1.1 21 1.47 2
35 SS COLD TUBESHEET 1.1 35 0.88 1
2 35 59 Colo TUBESHEET 2.4 28 4.50 2
35 60 HOT 3RD TSP 11.0 27 1.70
Sutt1 ART OF CY 1986 EDDT CURRENT INSPECTION DATA 0:19 WEDHESDAY. PtARCH 5. 1986 51 LISTING DF ALL TUBE FLAWS FOR STEArt GENE ATDR C2 e
STEAN GENERATOR RDW COLUNH LDC
' LAW LDCATIDH FLAW HEIGHT f!NCHES)
FLAW SIZE (7.)
DEFECT VOLTAGE 2
35 60 CCLD TutESHEET 2.4 12 3.80 2
35 61 HOT
.3RD TSP
.14.5 28 1.26 2
35 61 CPLD TUBESHEET 1.0 36 0.80 2
35 61 COLD TUBESHEET 1.7 23 1.95 2
35 62 CatD TUBESHEET 1.8 42 0.69 2
35 62 CSLD TUBESHEET 2.3 13 1.01 2
35 63 r0LD TUBESHEET 1.0 31 S.86 2
35 63 C3tD TUBESHEET 1.9 9
2.39 2
35 64 COLD TUBESHEET 0.7 29 2.20 2
35 64 00LD TUBESHEET 1.2 15 1.53 2
35 65 COLD TUBESHEET 1.1 25 5.18 2
35 66 COLD TUBE 5HEET 0.9 49 0.72 2
35 66 L3LD TUBESHEET 1.4 27 6.02 2
35 67 COLD TUBESHEET 1.1 21 4.93 2
35 63 HOT 2ND TSP 6.4 P4 1.26 2
35 68 HOT 3RD AVB 0.0 le 2.49 2
35 64 COLD-TUBESHEET 0.5 31 1.87 3
2 35 69 HOT 2HD TSP 6.4 29 1.23 2
35 70 HOT 2HD AVB 0.0 15 1.95 2
35 71 HOT 3RD AVB 0.0 37 0.89 2
35 73 HOT 2HD AVB 0.0 13 -
4.87 2
35 75 HOT TUBESHEET 1.2 13 0.85 2
35 75
. HOT 2HD AVB 0.0 4
4.54 2
35 76 HOT IST AVB 0.0 4
4.40 2
35 81 HOT 3RD TSP 26.5 4
3.20 2
35 81 HOT 3RD AVB 0.0 12 4.09 2
35 83 HOT 3RD AVB 0.0 11 3.17 2
35 84 HOT 2ND AVB 0.0 12 6.66 2
36 33 HOT TUBESHEET 4.6 52 0.76 2
36 33 COLD TUBE SHEE T 1.6 10 0 54 2
36 34 COLD TUBESHEET 1.2 10 5.11 2
36 38 COLD TUBESHEET 1.5 13 1.61 2
36 40 COLD TUBESHEET 2.4 16 1.81 2
36 40 COLD TUBESHEET 3.0 30 0.89 2
36 41 COLD TUBESHEET 2.4 31 0.82 2
36 41 COLD TUBESHEET 3.3 15 2.51 2
36 44 HOT 2HD TSP 33.6 16 1.69 2
36 47 HOT TUBE SHE ET 0.7 5
1.28 2
36 48 COLD TUBESHEE T t.0 20 0.97 2
36 51 HOT TUBESHEET 0.5 12 3.56 2
36 51 COLD TUBESHEET 0.8 8
1.45 2
36 52 COLD TUBESHEET 1.7 16 0.77 2
36 53 HOT 2HO TSP 4.1 42 0.79 2
36 53 HOT 2HD TSP 4.9 23 2.48 2
36 53 COLD TUBESHEET 1.6 17 1.51 2
36 55 HOT 3RD TSP 2.5 34 3.25 2
36 55 HOT 3RD TSP 4.1 23 1.36 2
36 55 HOT 3RD TSP 6.5 17 1.77 2
36.
55 COLD TUBESHEET 2.4 15 1.69 2
36 56 COLD TUBESHEET 2.1 22 2.88 2
36 57 COLD TUBESHEET 0.9 35 1.82 2
36 57 COLD TUBESHEET 2.3 24 3.66 2
36 58 COLD TUDESHEET 1.0 14 1.66 2
36 59 COLD TUBESHEET 2.2 23 1.75
SUmARY OF CY 1986 EDDY CURRENT INSPECTION DATA 0:19 WEDGSOAY. ttARCH 5.1986 52 LISTIHG OF ALL TUBE FLAWS FDR STEAM GENE!ATOR 82 e
STEAN GENERATOR RDW COLUMN LDC FLAW LDCATIDH FLAW HEIGHT IIHCHESI FLAW SIZE 1%I DEFECT VOLTAGE 2
36 60 COLD TUBESHEET 1.6 28 1.91 2
36 60 COLD TUBESHEET 2.1 17 2.86 2
16 61 HOT 3RD TSP 27.7 7
0.62 2
36 61 COLD TUBE SHE ET 1.2 31 1.96 2
36 61 COLD TUBESHEET 1.7 17 2.10 2
3e 62 HOT 3RC TSP 12.0 25 1.05 2
36 62 Hoi 3RD TSP 14.0 6
0.74 2
36 62 COLD TUBESHEET 0.8 34 0.87 2
36 62 COLD TUBE SHEET 1.7 22 1.28 2
36 63 COLD TUBESHEET 0.9 23 4.60 2
36 64 CCLD TL'BE SHE E T 1.1 24 4.52 2
36 65 HOT EMD AVB 0.0 4
4.29 2
36 65 COLD Yt'BESHE ET 0.8 22 1.85 2
36 65 C3LD TUBESHEET 1.3 17 2.13 2
36 66 COLD THBESHEET 3.2 28 2.29 2
36 67 COLD TUBESHEET 0.8 17 1.81 2
36 70 I;0T 2ND AVB 0.0 24 1.06 2
36 71 h0T 2*10 TSP
!!.0 16 1.41 2
36 71 C010 TUBESHEET 0.8 19 1.23 2
36 73 COLD TUBESHEET 32.3 4
0.68 2
36 74 HOT TUBESHEET 33.9 10 1.17 2
36 75 HOT TUBESHEET 0.5 23 1.15 2
36 77 HOT IST AVB 0.0 21 3.54 2
36 81 HOT 3RD AVB 0.0 13 1.19 2
36 82 HOT 3RD AVB 0.0 22 3.21 2
36 83 HOT 3RD AVB 0.0 21 1.01 2
36 84 HOT 2HD AVB 0.0 4
3.89 2
37 27 HOT TUBESHEET 2.6 19 1 !!
2 37 33 COLD TUBESHEET 2.1 3
0.91 2
37 47 HOT TUBES 4EET 0.9 29 6.40 2
37 St COLD TUBE SHE E T 1.6 5
1.46 2
37 54 COLD TUBESHEET 1.4 24 0.90 2
37 54 COLD TUDESHEET 1.8 11 0.84 2
37 55 HOT 3RD VSP 3.9 23 1.23 2
37 55 COLD TUBESHEET 1.7 15 2.38 2
37 56 COLD TUBESHEET 0.7 17 1.59 2
37 56 COLD TUBESHEET 2.1 13 1.75 2
37 57 COLD TUBESHEET 1.7 19 1.93 2
37 58 COLD TUBESHEET 0.4 11 1.32 2
37 59 COLD TUBESHEET 1.5 11 2.19 2
37 60 C01D TUBESHEET 1.0 41 0.88 2
37 62 COLD TUBESHEET 0.0 19 5.76 l
2 37 62 COLD TUBESHEET 1.1 3
1.31 2
37 63 COLD TUBESHEET 0.6 19 1.60 2
37 66 HOT 2HD TSP 5.2 16 1,51 2
37 65 HOT 2HD AVB 0.0 9
1.84 2
37 70 HOT 2ND AVB 0.0 36 2.19 2
37 7i HOT 3RD AVB 0.0 26 1.36 2
37 72 HOT 3RD AVB 0.0 12 I.67 2
37 73 HOT 3RD TSP 7.5 45 1.65 2
37 73 HOT 3RD TSP 8.5 55 1.34 l
2 37 73 HOT 3RD TSP 10.7 24 1.29 2
37 73 HOT 2HD AVB 0.0 24 2.64 2
37 73 HOT 3RD AVB 0.0 4
4.47
O 9
O M
w m
a e
J m
O e#44fe@mm@e@om+mNNeo@mM@eNN4N@NM@@@@@NG@o@@oo@NomWM@mN N. @. M. 4. e. m. W. N. @. @. @. W. G. N. N. @. o. m.@. @. f. M. f. m. M. @. m. &. @. @. m. M. N. @. @. <. N. W. &. m. m. o. d. m. G. f. N. N. a. N. @. N. @. N.
gu toNmoHNNmmNmNMNmmmNN4mmmmmmemomNmtoNmmommuomommmNNNon@
a U
e w
E bw O
d W
=
0 N
N
~
W O
N eNNm&Mmmoom@N@@@@mmm4N4Mm@dWM@@@m@mhW4N4CGoM@MCCMONNNm m
a MNmNammm*N fM MMMm m.mNM mammMMmN a
a N
mm am a
24&
b
=>
a
+1 m
O w
ZW m
w
- o. N. o. o. N. N. @.f. 4. M. o. o. o. o. W.@. a. b. o. G. o. d. o. o. o. o. o. N. #. e. f.o.C. o. N. C. @. o. o. o. o. o. h. o. @. @. f. m. W. o. o. o. o. o.
Uw ac Z
omoomeomooooooe@oNogoeoooooemeeomomomooooommamendooooo
$ <2 N Q
N M
m m
m m
o >
MJ w
- 8 p
Zwk 2
m$n<
a a
g"W uaC ao O
E ome wCw b
>>w
@ n. e m
w wwwwww ww ww www wwww e
w awwwwww mewwmamamaammmewwaamamwwwmememwwwwaammmmm
<54<r5a=mmo<<>>ZZ>m>m>m>>>>>5=mm>m>Z==>>>>>==== nom >>>>
um$
m ZZZ m
<mm<><><><<<<<
mr><>< nom <<<<<mmmm--r<<<<<
=>
8 mw w
wwwwww ww ww www wwww
> $ >Z r g 8 8 $$
ge>88a em>meZZZo Cagem $ >>Zog$$$$ca gogog ag mag
>m a
m uw 2
mW,m-
~mm amm
=>>>a ma ma on-a.
ma-mN>MWWWWNMmMMMNMMm M4f,MMMMMNMMMP>mm,MNM-MMMMWHM(eMN w
>a<
O O
OCO O
O C0 Ws>>>s>>waab>>W>>>>>>>>>>>ws>>>>>>a>>>>>>>as>>>>>>>>>>
C0000000000C000000000000000000000000000000000000000000
(
J 2 W Z..? T.W Z L U W U Z Z Z Z Z Z Z L Z *ZZ%ZZZUZZZZZZuzZZZZZZUu2ZZZZZZZZZ i
N NN-N.m,N@< < m 4 4 - N N -. m N # @ N m M M m 4 @ @ @ M M o M M N..N e @ a o N,M M M o o o m m m O O o efm4M
@amoNNNm NNN-N4NN-N~N.44-NN
.@N-NNm-m44444@ @@<
O U
N N N N N....... e e @ @ @ @ @ @ @ o,o,o,o o o o m,m m,m m,m,N,N,N N N N u u m - m a m m m m m m a,
M-Mmmmmmmmmme--------,
a 8>
I 4*
l W
l C
N.NNNNNNNNNNNNNNNNNNNuNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN t
E
<w>m l
l l
<m E
a m
o euen$.asenu
$.e.me<aeseeneseeeemennnn-nuamo<oemm. m. e. n. o. e.
. m. e. n. e. m. m. e.. e. m. u. o. n. o. e.. n.. e. m. <. o. o. s.
a
- m.. o. e.
~. e. <. e. o. n.
gu
~~-o-we<--<-<---memu--ouun-u--men #--munemme-a u
=
W r
aw a
><oe Y
Q N
w 3
w e
N-unnemumeem-em-m-nnemnekannmummecemeemo--n--n m
-m---
-m-u--u-nen--~~
u
~~ ~~~~
o 3<
d e
e u
w 3
-5 W
u
- a. a. <. e. e. e. o. o. o. o. o. o. o. o. o. o. o. o. o. <. e. w. o. o. o. o. o. o. o. o. o. o. o. o. o. o. o. o. o. o. o. o. o. e.
u a$u 5 -me-noooooooooooooonemeooooooooooooococooeon Ego
~~~
u
-d w
mm Z
> o
=ws 3
a $ a<
w
<a usw 40 o r a84 w w
- 8 > > >>
e ts n - w w
ww o=
w a w a w w e p e e a e e e e.m a m m a a t a m p m e m p e m e. e s e m p e m m a m.a l
e-
->E EmZnZZ>->
.. m m.
m.
merem<<<<<<<<<<<<<>>>><<<<<<<<<<<<<<<<<<r<>
u l
Mb o
w w
WW
>=
a So$a$$oZugoZooogenwoooo*>gookgogoZg>ZwZgoog-g ua u a awn ~=>a==_manamamen man.=_a
- ns am n_
3 mmmm>>me-umemmmNmm-mmmm--Nmm-umNmene-<ummu-u e
G d
b o
l u
>>s>>>>>>>>>>>>>>>>>>>>wwwwwwwww>>>>>>>>>www o uccooococooooooooooooooooooooooooooooooooooo l
w ZZu2ZZZ=31313324 EZZZZZZZZZZZZZZZZZZZZZZZZZZZ E
5 mn-ume<<aeeeeeo--~ con--me<<nocommeem-moummmu i
d Mm444@@@@@@@@4nnnnmmm444@@@@nnnmmmem4@
mem ou l
3
<<<<<<<<<<<<<<<<<<mmmmmmmmmmmmm........nnnee
= <<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<
8
-<Rw I
Zw unnuuuuuuuuuuuuuuuuuuuuuuuuuuuuunnununununun e
E<W e
I M
l'
n 9
s 9
P%
en e
lA EuEe E
4
+
w5 o.e a
so O
e--===--------.----.-------==-----.----e 8
I I
I W 9
4.A I e I @ I 4 8 G B N 8
- I f I N O O
4 I
f w Efl 4
= 8 0 0 M 8 N O I
e 0
0 & 5 0
0 0 9= e (1 E 2 0
I M 8
==e I
I O
8 8
8 I # 5 0
9 eO
,O4 a I
I e
0 0
e e
a 0
0 8 8 0 Z 0 J t I
8 I
8 I
e 8
8 0
g.g 8
0 0 9 8
4 m e e
e
.--+-----+-s==.I --.e --,0 e
+e a
> p Q p-+
e g
+.* +8 9
Q $
.J 8
I E 8
4 8 @ 0 @ g IA B M I
==s as
- 9 @ I i
p=
0 9 Q I w th 8 M S O f
.=e p 4 e B
e 0
0 C g i
I 8
.J t g62 0 4
I b I N a I
e 8
i B @ e 8
9 0 Q g Q4 0
. e I
e s
0 0
0
.t N e u.g u.
0 0
9
- 8
.O
--.I
+4
-- +- --.0
.I 8
.I
.$ -.0 i.
I E 1 0
t
-+
. +i #
-+
i I
I I
am i
in... e 8, se$ N.
I ~
>=
9 8
0 9
0 W 40 0 9
8 M I N 8 0
0 t
8 & 0 e.O U
9 8 9 8
8 b= 4 g62 0 M
=e e
I e
0 0
9 8 4 e 8.J e -.8.2O4 w
5 O e a
8 Q s e
s 9
e B
1 e
e I
a
. N.. r-8
. Z s
i i
i i
f m
I'
.i
.I
.e.
I 44.
B 0
0 I
awaiN i
---+---+-+-+-+-+- -+-+-i b ke W D >= w 4 8
B B R S
4 0 t>
B @ e in a M e.* e s's a a I
(>
e Q 3 Ef8 2 1 8
0 Q t w 46 I M I O t s.*
8 4 e e
8 8
i O I 14A ** >= 8 the 1 0
8 ia B g62 8 4 8 b $ N 8 I
I O
I 9 @ 0 Z4 0 Q4 I
i O 8 Q4 0
.* 8 8
B I
I O
8 8 N I h
and it t 0 e
i I W B
.J 9
8 I
I I
e 0
0 8
s g==
0m em.0.me m
- a. -.m + - - +== + - +
,a
.e
.e-.I
+e 8
R Isa 0
8 0
g I
e mZ 3
A 3 the i e
e e
t 9
e e
I e
I e
.J Q Q l 8
8 8
8 0
0 t
I e
8 8
4 5
0 0
0 8
0 0
I I
I O
e bE4 8
9 0
8 8
0 0
B B
B B
th Q 4 I O
8 8
8 I
9 8
6 5
0 0
1 G Q teif 9 0
0 8
8 I
B I
f I
8 0
the 9*
5 0
0 4
8 B
B D=
10 0 0
0 9
0 0
0 34 5
I I
I B
B 9
I a
0 0
0 4O8O
.I 8
0 j.
I I
I 0
0 0
0 0
i 8
I se b &
8 9
0 8
il 0
0 0
1 0
8 9
9 9
I B
'l l
8 1
e h
t 8
I I
il I
0 0
I l
Q f
9 9
8 il 9
0 0
0 8
8 0
0 8
e l
8 I
8 0
il 9
I e
i f
8 B
Il 8
3 0
0 0
8 t
9 i
t n
8 i
e i
0 8
0 0
I ll 0
9 0
0 0
I I
9 0
8 0
0 1
8 I
B I
i 0
I 6
0 8
8 I
9 0
9 0
0 I
I
-1 0
9 8
I 5
0 8
8 8
i 0
0 l
B I
e 1
8 0
I B
1 8
I I
O 8
0 l
0 I
B i
I I
8 I N4 8
e e
N 8 N I NeNO N I N I O e t
8 I
. @ 4 @
t (>
9 EF G (>
0 @ 8 O O.J t
I
- 'l las I N l N 0 m I 4 0 4A I N 4 @ 4 ** I 4 8 9
i
'I h4 1 O I
e 9 0 1
6 I e e e 9 a e e t >= I
'I re 8 N 8 O 9 0 0 eaO 8 O I O 9 0 0 Q 0 t
.-------_I.n.l
.y..O. N-.M _I.r.
.A, _n
- t. e s e, >-,
I t
I i
l 4
I s
'UMMARY OF ALL TUBE FLAWS 0:19 HEDilESDAY t1 ARCH 5.1966 56
- ~
FOR CY 1986 E00Y CURRENT INSPECTION FOR STEAN GLt2CATDR 52 a
l ISTEAN l l
l lGENER-l l
l l ATOR l l
l g......
l l
l 2 l TOTAL l l
l....__,....._l
'l lilut1BER ltattBERl l
l OF l OF l l
IFLAW3 l FLAWS l l__....____.
__________....,_.....,___...l l5IZE l
l l
g..... ________.______...___....l l
l l<2G%
l 17511 17511 l....___
120-29%
l 8151 8158 3.....__
__====............._,__..__,......l 130-39%
l 252l 2521 3.___.___.............................,_..___l 140-49%
l 69l 691 g..__
______,_.......____.1 150-59%
l Ill Ill
- . ___...__ ____..__==__
................l 110-79%
l 3l 31
.._..........l l%0-89%
i Il 11 l__..____
...........................____l f90-100%
l 41 41 l
3.________
.............l l
l TOTAL l 2906l 29061 l
l l
l l
l l
l l
1 l
.J
r_
4 d
9 e
d P
. pg (A
o a
d M
t
\\
be
- 1 hw$
. N
+
se ese t========== =.se ass a
..- e es..n.6 e m t
0 0
t iR 8
4 4 4 5 4 0 M 9 @ t N 4
- I 7 9 m8 8
9 0
0 W,J M 3 Id4 4 @ 0 98 % 9 N 8 4
0 0
IGW D
es. e. g 3 a. s e
o N s.
e,
,o e
a e
a s.
IQ.s 4+9 a
al i
4 a.
x B
4 8 U 6
9 eco. 4.m 0-.4.u.
8 e =. 4 6
.f 8
a.=.e 6
> 0 0 8
.s.
9 em.gm e w as. amo a=.
I
+ da.
=
em.
O. t t
me t 4 g n
4 4 P*
8 eaM eM
- e o e i> s 9
l 0 Q3 ens tJ B -. t c9 f 6 s
6 e
f@ l e
p.
I e
8
.A 9 g aa, 3 $
4 0 4 6 N 9 3
0 t
t t 4 4 8
% O9 Q
9 1
_ u t. c. 3 9 3
9 9
0
.i
.t 4
0 0
e
=
- m..t _
a w.
.e.
_ _ +,,.
e s
e as s
- 9..r e M eo.N e... en4 16A 0 9
8 I
I O W Ell 9 ers 9@ t t 64 9 0
8 9
lN 4 OO 3
& 4 I
i e-a w3s N s e
i e
e e
5 s 4 e 5
- 464 9
O 8 9
' O4 Q4 4 8
8 9
8 4
4 4
8 Wt & N 8 C >= 8 0
1 T. %
=J 9
8 e
4 6
8 0
0 8
(
Wl e e as est t 8O t
4 b.4.se see.-.
===.e
+==.6 69 4
8 f
I e
gg g wg p 44 g Q g eum +
s== am. am.
==.
- e. 6 a6. 41 un +
t ta,3 94 W $ Pe g4 9.e f
& R 8
@ 0
.P* 5 11 4 M 4 fet 5.* 9 ** 4
- A l' 9
(L Q t Wl, 9 4
4 Ot ens FJ'l 4 N 4
= 6 O 4 4 9 3
4 4
4 40 t
>=p.
a pa l 9
a
.a egS34
@ eeeN s 8
4 6
8 8 4 8 f4 2 (1.e q,D.0 0
- Qt Q4 4 4
8 8
4 8
8 8
8 ** I g
M.n.
u.i.
.m
_. +
w.
t
+-.,e M
W G G
9 9
9 0
0 l
- s I
ee e
a e
e a
e a
a i
i n
a s
e s
e t
9
)
e e
e 3( h T,I 1
e I
t i
4 8
9 4
eQRI S
5 4
6 8
I 8
4 I
I I
% G W 1, I-0 9
9 9
6 8
9 0
8 8
/
w e.
e s
e i
e e
e e
e i
i y) b t
O 8
9 9
6 4
8 9
a t
e e
e e
e e
e 4
e e
.X t t
6 4
0 e
p 8
+9 4
Q $
5 8
8 4
4 6
8 9
0 B
m.* es.
DC 4
4 4
5 4
5 4
3 a
G 9
4 6
0 0
9 I
I 8
0 4
4 8
1 9
g>
c p
i 9
0
)
0 0
4 6
1 4
Q g
4 4
4 4
4 9
9 4
f 4
4 6
9 9
9 4
4 0
4 8
0 8
QR l
8 5
0 4
4 8
4 1
0 5
t e
t 8
6 9
e i
i b la.
i b
l l
D f
9 I
i I
g 9
0 t
6 8
8 6
l' 8
e 3
4 6
e 1
h t
t t
t
}
g 6
5 4
3 8
9 4
4 8
e 4
6 6
5 0
0 f
9
(
l 4
4
-t 8
4 6
9 9
9 D
0 9
8 e
9 e
4 4
0 4
0 0 N8 4
a i
e e.4 $ itaweMeM eNaO e.I 4
)
I a fP I E>
9 CD 8 P 9 P 4 Ek f 14 9
O J
h enj & 't 4 N 8 P't f.7 8 ' eft 5 F*
I s e*
8 *(
0 e
)
i N $
'A 8 9 9 9 e e B 6 4 8 8 t 0 6 4 1p=
4 4
) M 3 ft 8 O 9 C 4 43 9 O 9 0 0 O 9 O $ Q6 6
4 g -===
e-m.
.=.=
se es..ti.l 4..y.==.sws..I.M e.f..I.=til.6. as m =@===l.C.h 8
h I 4 *= 5 an.
=
- = = t
- t
_ 1 s
SUPMARY OF MAXIttJM FLAW SIZES PER TUBE
. C !? WE0ffESDAY. tttRC) 5. iSC6 - 58 FOR CY 1986 ED0Y CURRENT INSPECTIOtt er n o* m '
d' FOR STEAM GENERATOR 82 o
l 15TEAN l l
l lGEtaER-l '
l l
l ATOR l l
l l______l 3
1 1 2 l TOTAL i 1
l------+------I I
lisuretattu eEhl I
I.Or I or f I
l Flows IFLatts l_.....________..__................... t IsIzE I
i l
3....__.___........._______.
. g l
.i l<2cx I
9151 9151 g........=
____l l20-29%
l 6591 6591 l_ ____......_.______________..,__..__,_____.g 130-39%
I
'2281 2281 l____...__--_.
________._........,______l 14e-49%
1 661 661 l_____......_________-==
__l 150-59%
i til til I.__.
...l 17o-79%
1 31 31 l_________.... ____..... __....,______,.. __.:
I il 1
g..........______..._.. ___. ___... __....... 1 l90-100%
l 41 4
l__________________.......
......_,______ll ITOTAL l 1887l 1087l d
4 1
i e
+
e e
a-w 3
e
T SurftARY OF TUBE INSPECTIONS BY EXTENT C217 WEDHESS % MapCH 0. 1986 5"J
,~,, )
FOR CY 1986 E00f' CURRENT INSPECT. ION C} 'qf i.
FOR STEAM GENEIATOR C2 Jgp l
4 STEAM l
l l
l GENERATOR l I
i l
g...........
l l
l 2
1 TOTAL
~l 1
l.............__....____g l
l HureER OF l HuhBER OF ?
I lif?SPECTIONS$1NSPECTIpHSl g...
4_.....
...l l LENGTH l
4 l
l__..............
..y l
l IFIPST SUPP0kT 1
Il Il 1.___.-
...l IstcOND SUPPORT l
Il 11' l.......... __.... _............ _.............. _____t lTwoo u-BEHO l
f(
ll g....__...
..........____...l lFuta. LENGTH l
36298 F6 C 91-1._________......
__I ITGTAL I
36tCl 3?dli 1
I I
I I
I
(
F l
,_)
At t;achment 1 (34 pagee total)
SUP9%RT OF CT 1966 EDDT C'JPPENT iteSPECTIDH CA1 A es ti. IM0t450AT, HANCH 5, 39e4 1
LISTitJG Cf' All. TLEE FLAWS EAM ETHE0ATOR 90W
' COL *JP90 LOC' FLAN LOCATION FI4W NEIGHT E ltlCHE51 FEAN'31ZE 329 9CFCCT YOLTh44 PAG (
1 2
71 NOT IST TSP 16.4 17 1.37 51 8
.t 96 HOT t'ID TSP 25.9
+3 1.42 31-I 3
14 MOT TUBE 5HEET 0.6 48
'5.29 34 1
3 20 NOT TUBE 5HEET 0.6 24 2.42 54 3
3 31 M3T TuetSHEEf 0.8 33 3.01 34 1
A 55 HOT M ESNEET 4.0 1
1.25 59 1
3-6b COLD YUBESHEtT
- 2. 0-14 1.Et 53 4
'5 69 COLO lime $HE E T 3. t.
Il 8.TF St I
3 70 HOT ltmESHEET 2.5 30 0.36 53 3
3
$9 F.0T TLBESHEET 2.5 78 6.76 51
' o.6 57 0.85 51 1
3 e9 HOT 3RC T3P r
I 4
35 C010 TUBESHEET 1.9 22 0.68 31 I
4 f*3t 0 IST TSP 29.5 15 1.41 31 3
4 84 COLO TUBFSHEET 1.2 2
1.09 31 1
4 W
COLO YtmESM ET
!<3 Il 8.87 31 1
4 tb COLD TL6ESHEET 2.0 36
~0.59 50 1
4 W
HOT TLeESHEET 2.*
14 1.17 55 8
4 62 HOT TLSESHEET 3.5 13 1.94 51 1
4 85 801' TUBE 5HEET 1.4 8 04 51 I
4 85 Cot 0 300 TSP 12.2 I2 1.75 51 1
'4 95 COLD 3RQ-TSP 33.9 10 1.1%
51 8
5 16 HOT TUBISHEET la 7
I.4S 17 3
5 23 C3tD
's ubE SHE E T 1.3 7
2.49 14
-1 5
26
'COLO TUDE5HEET 1.5 11 2.67 3
1 4
.t S
'Coto TUCf5 HEFT t.0 8
4.01 4
I 5
21 HDT TUBE 5HEET 2.4 3
2.40 4
1 5
'J 9
'CCLO
- Tuet3HEET
- 0. 9 to 3.32 4
3 5
29 CD' D TtMESHEET 2.3 5
1.78 1
5 30 CCLO YteESHEE1 0.6 4
1.54 5
1 5
- il HOT TLPESHEET 2.8 12 2.'45 5-1 5
31 COLD 1L;BESHEET 1.3 It 1.15 5
1 5
- 2 COLD it2ESHEET 2.8 8
8.14 6
1 5
36 HOT TLEE SHE"ET 0.8 11 1.32 7
3 5
42 HOT YteESHEET 3.4 31 0.57 31 I
5 44 COLO TU6E'AE ET 0.8 19 1.It 12 1
5 46 Cot 0 TUBE 5HEET 1.1 12 2.04 13 I
5 47 HOT 2HI) ISP O.6 16 f.37 13 1
5 44 COLO TUBE 5NEtt 1.5 1
2.15 14 5
5 50 NOT TursESHEL E 4.4 4L 0.43 15 3
5 53 COLO TUBEsiitt T' O.5 22 4.08 20 1
5 52 HOT TtEESHEET 2.9 IS 3.37 21 1
5 52 COLD TtmE5aECT
- 3. 3" 15 0.74 21 1
5 53 C0tD itMESHEEE I.9 24 0.94 23 1
4
'54 COLD TLCE5HEET 2.0 28 0.78 23 L
5 55 HOE TUDE5hEET 2.5 9
1.21 23 1
5 56 COLO TL*3ESHE ET 2.8 24 0.74 24 1
.5 57 COLD TuetSHEET 3.8 to 0.78 24 1
5 CS COLD TtMESHEET 2.I 17 1.23 25 1
5 59 HOT TtmtS4EET 2.9 12 1.16 25 1
5 69 HDT TUBESHfET 1.3 9
1.08 30 1
5 69
'f0tD TUBESH'EET 3.1 7
0.86 30 8
5 7C' COLO ftBE5HEET 1.9 8
0.84 31 1
5-78
' Cold 1t]SE5HEET 3.2
- 12 1,77 31
.1 5
76 COLO TLeESHEET 2.0 4
2.12 35 5
5 79 COLD TUBESHEET 1.8 6
1.06 36
4 e
4 e
N W
MMdeddamMMd@ONOmmmm...hheGe@DPDmhe@@
hmN
. PSP..@@
G MmMMMMMMm===MedmmmmMMmmmmWNNNNNm4MMMMMMMMMMMMMMMMMmmmmm e
.e O
m W
m O
4 5
5
- a. e.. e.e. m. e.
N. M. u. m. m. a. e. e. a.M. n. e. e. M. e. n.o. e. m.
. O G. # m. m M.... t. N M m,~ N < e e. < -
m.e. n. N. a. N. e. <. N.. M. n. e. a NomM~eM.Mm~~.me..
meM-W
.,<~
. e. e. M. a.
. e.. m. e. e.
g a
MONamONNammmNMNewmN=emOMmmemmemmmmesmNNOOmNNmNmMMNOWNON f
E k
M o
i k
w 4
h o
W 2o B
=
m N
=
=
g Y
l N
M@.mNeb@@m.4@e.N@mPOWNNMN.eNthdMOmh@mOmPWMOShmOWNWhW.mo M
M me mm um e
o mmmmmN Num Nummmmmmu m
um m
m 24 b
4>
Wo N
M w
Z u
y w
E.
@ @ M. N. O. N. d.@.M.. O. m. m. m. m. O. 4. m. m.e. m. e.m. b. e.k.. m. e.d.e.m.4. M.N. M.m.@. m.d.@. N. M.d.e.f.. m.t.h.h.t.e..
rem-mN-=<=Mmm--mN-mN.<---.m.mWMmMNmmmM.m-mm--mm-mmeN.n.
-d a
W E
{
m w
I ZW M
Wg W
Z ag 2
ud 4
e a k4 h
o b
22
.- z m-o khkkkkkkkkkkkkkkkkkkkkkkkW H
kkkkkkkkkkk>
wwwwwww wwwwwwWwwwwwwwwwwwwwwwwwww W
wwwwwwwwwwww WW W
M M
EwwwwwwWEwwwwwwWWWWWwwwWWWWwWWWWwWWEW&WWWWWwwWWWWWEWWEW kM
-MMMMMMMMM6MMMMMMMMMMMMMMMMMMMMMMMM-M EZZZMZZZZ4%ZMSZME MZZZZZZZMZ*ZZZZZZZZZZZTIZZZZZZZZZZZMZM wMMMwpMMMMMM-MM-w ud 4
8 wwwwwww wwwwwwwwwwwwwwwwwwwwwwwwww w
wwwwwwwwwwww ww w EEBEBEEBEBBBBEEEBBBEM-EEEEEEBEEBEBEE28888EEEBBEEB2888E h
BBB M
F MM--Fr
-N M----
-M--N k
=
a 4
4 a
b I
f kkSSSkSS*kkSSSSSSSSShkSSSSSSSSSSSSkkSSSkkSSSFSFSSSkkSkS X EoooooooooEooooooooofoooooooooooooooooooooootoooooooooo zuuuzou==
uuuuuuuuu zuuuuuuuuuuuu==uouzzuuu umouuzzu=u i
e I
- x ommem.
.nNMMNueeoa=NmueeeeNNMM nWM.e.a..neeeNM'$.9 20 4.27 1
Il 81 COLD TUBESHEET t.8 15 3.52 1
Il 82 COLD TUBESHEET 4.0 6
3.97 1
11 84 COLD TUBE 5HEET 11 7
2.26 1
II 85 COLD TUBESHEET 81 6
1.76 4
11 86 HOT 3RD TSP 9.4 30 1.61 1
il 87 HOT 3RD TSP 9.5 7
2.36 1
11 87 COLD TUBE 5HEET 33 7
1.54 1
12 15 HOT 2ND TSP L8.6 4
0.94 1
12 15 HOT 3RD TSR L7.8 40 0.41 1
12 15 NOT 3RD TSP L9.7 40 0.92 1
It 16 COLD TUBESHEET
$.5 11 2.42
$2 17 COLD TUBE 5HEET 3.7 27.
2.71 12 17 COLD TUBESHEET 2.8 4
4 74 1
12 18 COLO TUBE 5HEET 4.5 28 1,49 1
12 19 COLD TUBE 5HEET 3.9 5
2.04 1
ft te NOT END TSP 9.0 26 3.79 1
12 20 COLD TUBE 5HEET 0.8 11 2.28 1
12 21 HOT 2ND TSP 15.1 25 1.60 1
12 21-COLD
.TUBESHEET 3.9 19 3.64 r
1 12 22 COLD TUBESHEET 1.0 5
1.00 l
1 It 24 CCLD TUBE 5H(ET 0.9 9
3.09 1
It 25 COLD TUBE 5HEET 0.8 12 8.42 1
12 26 COLD TUBESHEET 1.0 le 3.27 1
12 27 COLD TUBESHEET 4.9 l4 2.62 1
12 28 COLD TUBE 5HEET 90 r3 4 51 1
12 29 COLD TUBESHEET 07 le 3.14 1
12 30 COLD TUBESH(ET 96 11 1.64 1
12 30 COLD TUBESHEET
$.0 9
0.69 1
12 31 COLD TUBESHEET 33 15 2.73 1
12 32 COLO TUBESHEET 0.7 16 3.21 1
12 33 COLD TUBE 5HEET
$.7 14 2.43 1
12 34 COLD TUBESHEET 1.0 16 2.60
SUPetARY OF CY 1986 EDDY CtJICENT INSPECTION DATA 0:15 NEDHESDAT, MARCH 5, 1986 7
LISTINB 0F ALL TUBE FLAWS FOR STEAM SENE0ATDR 91 STEAM SENERATOR ROM COLUP04 10C FLAN LOCAT!0H FLAN HEIGHT IINCHES)
FLAN SIZE (%)
DEFECT VDLTADE 1
It 35 COLD TUBESHEET 19 14 1.97 1
It 36 COLD TUBESHEET l.2 25 2.$4 1
12 37 COLD TUBESHEET 1.2 16 1.47 1
12 40 COLD TUBESHEET 1.0 12 2.28 1
42 41 COLD TUBESHEET 12 23 1.83 h
1 12 42 COLD TUBE M ET l.2 14 1.72 1
12 44 COLD TUBESMEET 3.5 1
1.42 l
1 12 46 COLD TUBESHtET 4.0 30 1.4T 1
12 44 COLD TUBESHEET 1.3 16 1 47 1
11 67 COLD TUBESHEET 1.1 le 2.62 1
12 68 COLD TUBESHEET 0.8 19 1.07 1
12 69 COLD TUBES $EET 1.0 4
2 47 l
1 It 71 COLn TUBESH ET f.5 17 f.$
g i
1 12 72 COLD TUBESH ET 98 5
4 38 l
1 12 73 Cot D TUBESH ET 99 7
2.06 1
It 74 CCLD TUBESHEET 10 20 1.57 1
12 76 HOT 3RD TSP 12.0 19 1.49 1
12 76 C0tB TUBESHEET 1.0 19 1.77 l
1 12 77 CCLD TUBESHEET
{.1 7
4.15 1
12 78 COLD Tt2ESHEET 0.8 7
4.70 1
12 79 COLD TUBE 5HEET 3.9 3
2.77 1
It 40 COLD TUBESHEET 4
14 3.99 d' N M N
.9 1
It
$1 FOLD TUBESHEET l.0 31 3.30 1
12 82 COLD TUBESHEET 3.9 18 3.65 a
1 12 83 COLD TUBESHEET 1.2 5
3.26 8
It 64 NOT 3RD TSP 6.3 16 1.5$
(
1 12 SS NOT 3RD TSP 9.9 24 1.49 1
It 95 COLD TUBESHEET 1.3 18 2.$1 i
L 1
12 86 HOT 3RD TSP 4.3 35 2.42 l
1 12 46 COLD TUBESHEET 1.2 14 2.53 1
12 88 HOT 3RD TSP 25.8 34 0.65
(.
I 12 91 NOT 3RD TSP 3.8 25 2.99 1
13 12 HOT 3RD TSP 11.8 31 1.54 l
1 13 16 COLD TUBESHEET 0.8 7
2.02 1
13 17 COLD TUBESHEET 0.7 27 1.34 1
13 la COLD TUBESHEET 0.9 19 2.86 1
13 18 CO LD TUBESHEET 1.2 4
2.02 1
13 20 HOT 2HD TSP 4.5 15 1.17 1
13 20 Cata TUBESHEET 0.9 5
5.11 1
13 21 NOT IND TSP 9.4 18 1.03 I
1 13 2)
COLD TUBESHEET 0.9 12 4.21 l
1 13 22 CGLD TUBESHEET 3.5 1
2.82 1
13 23 COLD TUBESHEET 0.7 10 2.91 1
13 24 COLD TUBESHEET 0.8 16 2.23 l
1 43 25 NOT END TSP 5.2 31 1.44 1
13 25 COLD TUBESHEET 0.6 19 2.35 i
1 13 26 COLD TUBESHEET
~ 1.0 6
2.72 1
13 27 COLD TUBESHEET 1.0 13 2.36 1
13 28 COLD TUBESHEET 0.8 15 3.13 1
13 29 C0tD TUBESHEET 0.7 18 3.99 1
13 30 COLD TUBESHEET 0.7 19 2.98 1
13 31 COLD TUBESHEET 15 14 E.76 1
13 32 COLD TUBESHEET 1.0 9
2.62 1
13 39 COLD TUBESHEET 0.6 13 1.94
SLM1 ART OF CT 1966 EDDT MENT IN$PECTIGH DATA 9:15 HEDHESDAYo MARCH 5, 1986 8
LISTIf46 0F ALL TUBE FLANS FOR STEAM GENERATDR 81 STEAM GENERATOR ROM COLLAW LOC FLAN LOCATION FLAN HEIGHT IIHCHESI FLAN SIZE 1%)
DEFECT VOLTAGE I
13 40 COLD TURESHEET 3.9 4
t.67 1
13 41 COLD TUBESHEET 1.8 17 1.56 1
13 43 COLD TUBESHEET 12 le 1.64 1
13 47 COLD TUBESHEET 3.9 te 0.42 1
13 48 HOT TUBESHEET 3.8 15 1.47 1
13 49 HOT TUBESHEET 2.5 39 4.44 1
13 50 HOT TUBESHEET 7.3 28 t.12 1
13 54 COLO TUBESHEET 1.5 17 1.88 1
13
$8 COLD TUBESHEET 1.5 6
2.15 1
13 61 COLD TUBESHEET 1.6 5
1.84 1
13 67 COLD TUBESHEET S.9 tt 1,54 1
13 67 COLD TUBESHEET 1.1 14 1.26 1
13 p6 COLD TUBESHEET 0.8 17 3.56 g
1 13 49 COLD TUBESHEET 1.8 19 4 40 1
13 70 COLD TU6ESHEET 1,8 to 4.$5 1
13 71 COLD TUBESHEET
-$.4 18 1.18 1
13 71 COLD TUBESHEET 8.6 19 1.18 1
13 72 CGLD TUBESHEET 1.0 4
2.et 1
13 73 COLD TUBESHEET 3.7 1
2.72 1
13 74 COLD TUBESHEET 3.8 13 2.66 1
13 76 HOT 3RD TSP 2.3 56 6.51 1
13 76 COLD TUBESHEET
' 9' I% 11 A " 3.1 4
1.99 j
1 13 77 COLD TUBESHEET 51 6
3.82 1
13 78 COLD TUBESHEET 0.8 17 4.40 1-13 79 COLD TUBESHEET 1.0 7
1.73 1
13 St COLD TUBESHEET 0.9 16 2.55 1
13 81 COLo TUBESHEET 3.9 15 3.67 1
13 42 COLD TUBESHEET 1.0 8
4.74 1-13
$3 HOT TUBESHEET 8.5 8
1.55 1
53 83 COLD TUBESHEET t.9 13 3.12 1
13 84 COLD TUBESHEET 4.9 3
1.75 1
13 64 HOT 3R0 TSP 6.4 33 1.34 1
13 49 HOT 3R0 TSP 13.7 29 1.22 1
14 12 HOT 3R0 TSP 18.1 to 1.70 1
14 17 COLD TUBESHEET 0.6 20 3.44 1
14 18 COLD TUBESHEET t.6 21 2.44 1
14 59 COLD TUBESHEET 1.0 10 2.94 1
14 19 COLD TUBE 5HEET 3.1 15 1.45 1
14 28 COLD 1UBESHEET 1.0 9
3.82 1
14 20 COLD TUBESHEET 3.1 5
2.93 1
14 21 COLD 1UBESHEET 0.8 16 3.50 1
14 22 COLD TUBESHEET 1.0 7
4.15 1
14
$3 COLD TUBESHEET 4.7 9
8.35 1
14 24 COLD TUBE 5HEET 1.1 18 9.96 3
14 25 COLD 10BESHEET 4.7 6
3.37 1
14 26 COLD TUEESHEET 8.9 9
2.81 1
14 27 COLD TUEESHEET S.6 13 2.68 1
14 28 COLD TUBESHEET 0.6 17 3.13 1
14 29 COLD TUBESHEET 8.6 10 3.61 1
14 30 COLD TUBESHEET 8.5 14 2.79 i
1 14 31 COLD TUBESHEfT 1.3 18 2.74 1
14 35 totD TUBE 5HEET 4.8 19 1.00 1
14 36 C3LD TUBESEEET
-0.6 6
3.20 1
14 39 COLD 1UBESHEET 0.6 11 1.72 l
SL29 TART OF CT 1986 EDDT CtstRENT INSPECTION DATA 0815 NEDHESDAT. MARCH 5. 1986 9
~
LISTIHS OF ALL TUBE FLAWS FDR STEAM SENERATOR 81 STEAM SEPERATOR ROM COLLR94 LOC FLAN LOCAT10N FLAN HEIGHT IINCHE51 FLAN SIZE (X)
DEFECT VOLTAGE i
1 84 49 COLD TUBESHE$T 0.9
?
8.09 1
44 41 COLD TUBESHEET 99 10 1.30 1
14 45 COLD TUBE 5HEET 1.1 15 4.24 1
14 44 COLD TUBE 5HEET 1.5 7
2.91 1
14 47 COLD TUBE 5HEET 1.5 8
1.87 1
14 54 COLD TUBE 5HEET
$.2 8
1.28 1
14 59 COLD TUBE 5HEET 14 11 9 91 1
14 63 COLD TUBE 5HEET 31 1
2.66 1
14 64 COLD TUBE 5HEET 9.9 9
4.12 1
44 65 COLD TUBE 5HEET 2.2 3
1.29 1
44 6$
COLD TUBE 5HEET 3.8 17 3.71 1
44 68 COLD TUBE 5HEET 2.0 3
0.53 1
14 69 COLD TUBE 5HEET 9.7 19 U.31 g
)
14 70 COLD TUBE 5HEET 4.0 10 3 29 1
!)
71 COLD TUBE 5HEET 3.3 15 2.97 1
14 72 COLD TUBE 5HEET 0.9 21 1.74 '
1 14 73 COLD TUBE 5HEET 9.8 It 1.98 1
14 74 COLD TUBE 5HEET 3.8 13 2.11 1
14 75 COLD TUBESHEET 1.1 7
3.11 1
14 76 COLD TUBE 5HEET 4.9 14
.t.59 1
14 77' COLD TUBE 5HEET 1.1 11 E.62 1
14 78 COLD TUBESHERT 3.8 6
{.04
" U I'I" $.9 6
2.18 1
44 79 COLD TLBESHEET 1
$4 80 COLD TUBE 5HEET 1.0 12 3.07 1
14 81 COLD TUBE 5HEET 31 21 3.18 1
14 82 COLD TUCE5HEET 1.1 12 3.44 1
14 83 NOT 3R0 TSP 8.0 24 1.30 l
1 14 83 COLD TUBE 5HEET 44 9
3.25 1
14 85 COLD TUBE 5HEET 1.2 7
3.52 1
14 07 HOT 3R0 TSP 37.9 3
C.53 1
15 17 HOT TUBE 5HEET 1.1 20 3.05 1
15 17 COLD TUBE 5HEET 4.6 18 1.33 1
15 18 HOT TUBE 5HEET 1.2 17 6.64 1
15 18 COLD TUBE 5HEET 4.4_
.15 2.84 I
15 19 COLD TUBE 5HIET 4.9 15 2.67 1
15 19 COLD TUBE 5HEET 1.2 -
8 1.77 1
15 20 COLD TUBE 5HEET 0.9 14 4.39 1
15 21 COLD TUBE 5HEET 4.9 6
4.58 I
15 22 COLD TUBE 5HEET 0.7.
18 2.25
.l 1
15 23 HOT 3RD T5?
33.5 6
1.01 1
15 23 COLD TUBESHEET 0.9 9
2.12 1
15 24 COLD TUBESHEET 0.7 11 3.14 1
15 25 COLD TUBE 5HEET 0.7 17 2,?S 1
15 26 COLD TUBESHEET 0.7 19 1.82 1
15 27 COLD TUBE 5HEET 9.6 12 3.66 1
15 28 COLD TUBE 5HEET 0.5 10 3.48 1
15 30 COLD TUBE 5HEET 0.6 26 2.57 1
15 31 CCLD TUBE 5HEET 0.9 21 1.51 1
15 32 COLD TUBESHEET 4.7 14 1.64 1
15 34 HOT TUBE 5HEET 3.2 26 3.70 1
15 39 COLD -
TUBE 5HEET 4.7 19 2.42 1
15 40 HJT TUBE 5HEET 5.2 22 0.53
)
15 41 COLD TUBE 5HEET 3.9 29 0.77 1
15 45 COLD TUBESHEET 1.0 8
3.68 j
SUPMART OF CY 1964 EDDT CURRENT INSPECTI0it DATA 0215 NEDHESDAYo MARCH 5, 1986 10 LISTINE OF ALL TUBE FLANS FOR STEAM SENERATOR 91 STEAM SENERATOR R04 COLT #94 LOC FLAN LOCATION FLAN HEIGHT IIHCHES)
FLAN SIZE EX)
DEFECT VOLTA 8E I
15 48 HOT TUBESHEET 4.0 27 0.42 1
15 43 CDLD TUBESHEET 1.5 t
2.06 I
15 49 s\\
COLD TUBESHEET 1.2 14 2.01 1
15 51 HOT TWESHEET 4.4 3
15 56 COLD TUBESHEET 1.1 24 0.95 7
1.38 -
1 15 58 COLD TWESHEET 2.6 5
0.47 8
15 59 COLD TWESHEET 3.3 4
1.47 1
15 62 COLD TUBESHEET 3.7 3
4 45 5
15 63 COLD TUBESHEET 0.9 3
4.03 1
15 64 COLD TWESHEET 3.2 10 3.67 1
15 66 COLD TWESHEET 35 25 4 44
~1 35 67 COLD TUBESHEET 1.3 4
2.90 1
15 67 COLD TUBESHEET 3.3 5
1.92 g
1 15 68 COLD TUBESHEET 3.2
$1 3.41 1
15 68 COLD TUBESHEET 31 12 1.72 1
15 69 COLD TUBESHEET 3.4 28 3.21 1
15 70 COLD TUBESHEET 80 15 2.21 1
15 71 COLD TUBESHEET 08 29 1.73
~1 15 72 COLD TUBESHEET
$.8 25 1.89 1
15 72 COLD TUBESHEET 1.2 13 2.74 1
15 74 COLD TWESHEET 0.8 11 t.75 1
15 75 COLD TUBESHEET 3
19 1.91
- 8*'"b Y
.2 1
15 76 HOT TWESHEET 1.2 11 1.65 1
15 76 COLD TUBESHEET 31 9
3.87 1
15 79 COLD TUBESHEET 40 12 3.50 1
15 80 COLD TUBESHEET.
1.0 58 4.65 1
15 81 COLD TUBESHEET 11 15 3.09 1
15 82 COLD TUBESHEET 14 6
4.53 1
15 83 COLD TWESHEET 1.2 6
4.07 1
15 85 COLD TUBESHEET 2.0 5
1.68 1
15 87 HOT 3RD TSP 6.0 32 1.50 1
46 12 HOT 3R0 TSP 0.9 37 1.18 I
16 17 HOT TUBESHEET 1.0 I4 7.44 1
16 19 COLD TUBESHEET 3.9 4
4 45 1
16 20 COLD TUBESHEET 3.8 3
2.73 1
16 21 COLD TUBESHEET 1.0 19 3.49 1
16 22 COLD TUBESHEET 0.6 15 1.02 1
16 22 COLD TUBESHEET 1.1 6
1.66 1
16 23 COLD TUBESHEET 1.0 19 2.99 1
16 23 COLD TUBESHEET 3.7 7
0.97 1
16 24 COLD TUBESHE$T 3.8 22 1.04 i
.1 16 25 COLD TUBESHEET 17.2 It 1.61 1
16 26 COLD TUBESHEET 1.0 5
1.73 1
16 27 COLD TWESHEET 0.8 21 3.12 l
I 16 28 HOT TUBESHEET 0.4 37 I.89 l
1 16 28 COLD TUBESHEET 4.6 15 3.59 l
1 16 29 COLD TUBESHEET 3.7 8
2.17 1
16 30 COLD TUBESHEET 3.6 12 2.48 I
16 31 COLD TUBESHEET 0.7 9
2.93 1
16 32 COLD TUBESHEET 3.5 E7 1.85 1
16 33 COLC TUBESHEET 1.0 19 1.53 1
16 40 HOT TUBESHEET 6.8 D
0.80 1
16 40 COLD TUBESHEET 0.6 19 2.51 1
16 41 COLD TUBESHEET 2.3 6
0.88
SLR9 TART OF CT 1906 ED0Y CLEIRENT INSPECTION DATA 0 15 NEDHESOAT. ItARCN 5: 1906 he i LISTING OF ALL TUBE FLAWS FOR STEAN SE6E2ATOR C1 STEAN SEMERATOR ROM COL 1998 LOC FLAN LOCATION FLAW HEIGHT IINCHESI FLAN SIZE IXl DEFECT VOLTA 8E 1
16 45 COLD TUBESHEET 3.7 19 0.86 1
86 46 COLD TUBESHEET t.0 23 2.57 1
16 46 COLD TUBESHEET 4.9 3
2.24 1
16 49 COLD TUBESHEET 1.5 14 2.27 1
16 53 HOT TLBESHEET 4.4 16 0.77 1
16 53 COLD TUBESHEET 44 87 1.26 g
I 16 57 HOT TUBESHEET 5.9 14 0.94 1
16 58 COLD TUBESHEET 3.5 19 0.83 1
86 59 COLD TUBESHEET 1.0 4
1.14 1
16
$2 COLD TUBESHEET 4.6 14 1.26 1
46 64 COLD TUBESHECT t.2 14 1.04 8
16 45 COLD TUBESHEET t.3 5
1.74 1
,6 66 COLD TUBESHECT 84 16 1.77 g
l'
.6 65 COLD TUBESHEET 4.9 25 2.73 1
56
$8 COLD TUBESHEET 1.9 5
8 43 j
1 16 69 COLD TUBESHEET 0.8 31 1.42 1
16 70 COLD TUBESHEET 9.7 26 2.36 1
16 78 COLD TUBESHEET 4.7 14 2.26' 1
16 72 COLD TUBESHEET 4.8 14 2.04 1
16 74 COLD TUBESHEET 3.8 20 1.93 1
16 75 COLD TUBESHEET 35 14 0.79 1
16 76 HOT TUBESHEET
"'l""N,""$.4 6
1.74 8
16 76 COLb TUBESHEET 16 5
2.92 1
16 77 COLD TUBESHEET 31 6
3.41 1
16 78 COLD TUBESHEET 0.6 11 3 54 1
16 79 COLD TUBESHEET 9.9 6
3.47 1
16 80 COLD TUBESHEET 0.9 10 2.86 1
16 81 COLD TUBESHEET 1.0 6
3.58 1
16 83 COLD TUBESHEET 1.1 2
1 36 1
17 19 COLD TUBESHEET 1.0 6
2.73 1
17 to COLD TUBESHEET 3.7 9
3.33 1
17 21 COLD TUBESHEET 40 19 2.46 1
17 23 COLD TUBESHEET 1.1 19 2.19 1
17 24 COLD TUBESHEET 0.7 14 2.54 1
17 25 COLD TUBESHEET 0.9 18 2.27 1
17 26 HOT TUBESHEET 1.2 8
2.90 1
17 27 COLD TUBESHEET 1.2 16 4.54 1
17 28 COLD TUBESHEET 0.8 14 3.60
't 17 29 HOT TUBESHEET 0.2 15 1.34 1
17 29 COLD TUBESHEET 0.8 18 2.87 1
17 30 COLD TUBESHEET 3.9 19 3.95 1
17 31 COLD TUBESHEET 3.8 12 2.46 1
17 32 COLD TUBESHEET t.8 9
2.40 1
17 35 COLD TUBESHEET 1.0 25 2.10 1
17 34 COLD TUBESHEET 2.6 19 3.50 j
1 17 37 COLD TUBESHEET 4.7 9
3.23 1
17 40 COLD TUBESHEET 3.7 6
2.30 1
17 41 COLD TUBESHEET 1.8 4
1.82 j
1 17 45 COLD TUBESHEET 4.4 22 3.32 i
1 17 46 COLD TUBESHEET 1.0 43 1.59 1
17 52 COLD TUBESHEET 1.6 14 2.68 1
1 17 55 COLD TUBESHEET 3.2 5
1.52 1
17 56 COLD TUBESHEET 1.1 8
2.09 1
17 65 COLD TUBESHEET 2.0 15 2.10
l SLDOWIT OF CT 1986 EDD M R M INSPECTION DATA 0:15 WEONESDAT,IWIC80 5. 1986 12 LISTING OF LL T N FLAWS FOR STEAtt SENERATOR 81
[
STEAM SENERATOR ROM COLT 994 LOC FLAN LOCATION FLAW HEIGHT IIHCHESI FLAN SIZE (%)
DEFECT WOLTAGE I
17 66 COLD TLBESHEET 1.0 le 1.70 1
17 67 COLD TimESHEET 11 11 4.35 1
17 67 COLD TimESHEET 2.0 5
2.89 1
17 69 COLD TUBESHEET 0.7 48 1.97 1
17 70 COLD TtBESHEET 0.7 26 3.93 1
17 71 COLD TUBESHEET 08 l8 4 74 1
17 72 COLD TUBESHEET 10
-9 1.01 1
17 73 COLD TUBESHEET 10 1
17 74 COLD TUBESHEET 0.8 me f.22 le 3.43 1
17 75 COLD TUBESHEET 0.6 to 3.51 1
17 76 COLD TUBESHEET 1.4 2
2.92 1
17 77 COLD TUBESHEET 11 12 3.43 1
17 78 HOT 3RD TSP 13.8 36 3.30 g
1 17 78 HOT 3RD TSP 15.4 22 1.57 1
17 78 COLD TUBESHEET 3.6 7
4.54 1
17 79 COLD TUBESHEET 1.0 16 4.64 1
17 80 COLD TUBESHEET 1.0,
24 4.11 1
17 41 COLD TUBESHEET 1.1 5
2.98 1.
17 83 COLD TUBESHEET 3.1 5
1.89 1
18 19 COLD TUBESHEET 0.8 15 2.75 1
18 20 COLD TUBESHEET 0.7 9
4 49 1
18 22 COLD TUBESHEET
- NP t.3 2
2.13 1
18 23 COLD TUBESHEET 1.0 24 0.76 1
38 24 COLD TUBESHEET 0.8 16 2.84 1
18 25 COLD TtBESHEET 0.7 15 1 95 1
18 26 COLD TUBESHEET 1.0 23 2.98 I
18 27 COLD TtBESHEET 1.0 8
4.14 1
18 te COLD TUBESHEET 3.9 It 4.40 1
18 29 COLD TISESHEET 0.8 10 2.84 1
18 30 COLD TUBESHEET 0.7 25 4 15 1
18 31 COLD TUBESHEET 1.2 14 1.87 1
18 32 COLD TLBESHEET 0.7 19 2.47 1
18 33 COLD TUBESHEET 4.9 17 4 59 l
1 18 35 COLD TtmESHEET 1.0 28
'.11 h.It 1
18 36 COLD TtSESHEET 1.0 26 1
18 37 COLD TUBESHEET 0.7 11 3.03 1
18 38 HOT TimESHEET 2.4 11 1.25 1
18 40 CO.D TUBESHEET 2.1 12 1.25 1
18 4)
COLD TUBESHEET 0.5 10 2 51 1
18
$1 COLD TUBESHEli 1.9 9
1.e4 1
18 43 COLD Tt2ESHEtI e.4 11 a 66 1
18 46 HOT TUBESHE(T 2.2 70 1.00 1
18 48 COLD TUBESHECT 2.3 8
1.84 1
18 49 HOT TUBESHEET 4.6 14 0.84 1
18 49 COLD iteESHEET 2.0 18 1.40 1
18 51 COLD TUBESHEET 1.4 5
1.35 1
18 53 HOT TUBESHEET 9.1 25 9 68 1
18 53 COLD TimESHEET 1.1 18 4.94 1
18 56 COLD TtmESHEET 4.8 24 4 52 1
18 65 COLD TUBESHEET 1.9 8
2.44 1
IS 66 COLD TUBESHE5T 1.2 le 1.73
'I 18 67 COLD TLBESHEET 1.0 18 4.30 1
18 68 COLD TUBESHEET 3.9 19 2.90 1
18 69 COLD TUBESHEET 0.9 29 1.05 t
m m--
SLRetARY OF CT 1986 EDDY CLMRENT INSPECTICH CATA 0:15 NE0HESOAY. MARCH 5. 1946 13 LISTING OF ALL TUBE FLAMS FOR STEAM GENERATOR 81 STEAM SEHERATOR RON COL 1891 LOC FLAN LOCATION FLAN HEIGHT !!HtHES)
FLAN SI2E IX) bEFECT VOLTA 8E I
18 71 COLD TUBESHEET 98 13 1.42 1
IS 72 COLD TUBESHE$T 51 6
8 84 1
18 73 COLD TUBESME$T 4.9 le 2.80 1
18 74 COLD TUBESHERT 1.1 7
3.22 1
18 75 HOT TUBESHEET
$.7 le 1.88 1
18 75 COLD TUBESHEET
).5
$8 4.54 1-18 76 NOT SHD TSP 10.9
).42 1
le 78 COLD TUBESHEIT 99 it 2 16 1
18 79 COLD TUBESHEET 0.9 6
2.98 1
18 80 COLD TUBESHEET 1.0 3
3 54 s
I 18
$1 COLD TUBESHEET 9.9 4
j.07 1
18 82 COLD TUBESHEET e.8 le 4 01 I
18 87 HOT TUBESHEET 3.9 39 9 59 g
8 18 98 HOT SHD TSP 31 5 6
15$
1 19 HOT 3RD TSP 8.9 45 3.19 1
19 20 COLD TUBESHEET 0.5 21 3.03 1
19 21 COLD TUBE $HEET 2.9 le 3.34 1
l 1
39 22 COLD TUBESHEET 1.8 5
1.78 I
19 23 COLD TUBESHEET 1.2 15 3.09 1
19 24 COLD TUBESHEET 8.6 23 0.97 1
19 24 COLD TUBESHEET 1.3 9
1.76 1
19 25 COLD TUBESHEET
' ff""9"I"'4 0 23 1.68 1
19 26 COLD TUBESHEET I.1 6
2.21 1
19 27 COLD TUBESHEET 4.9 16
}.89 1'
19 88 COLD TUBESHEET 9.9 lt 1.99 1
19 29 COLD TUBESHECT 99 lj I.39 1
19 30 COLD TUBESHEET 49' 12 1.74 1
19
'31 HOT TUBESHEET 1.4 le 0.79 1-19 31 HOT 3RD TSP 1.7 26 1.33 1-19 31 COLD TLBESHEET 12 I4 1.93 32\\g 1
19 HOT TUBESHEET 8.5 15 1.47 1
19 32 COLD TUBESHEET 1.0 13 1.66 g
1 19 53 COLD TUBESHEET s.8 16 2.44 I
1 19 34 COLD TUBESHEET 11 It 3.09 8
19 35 HOT TUBESHEET 14 1
3.83 1
19 35 COLD TUBESHEET 1.0 26 3.65 1
19 56 COLD TUBESHEET 8.5 14 2.38 1
19 38 COLD TUBESHEET 3.7 29 1.40 1
19 38 COLD TUBESHEET 2.1 10 1.89 1
19 39 COLD TUBESHEET-0.6 6
2.77 1
19 40 COLD TUBESHEET 0.3 17 4 96 1
19 41 COLD TUBESHEET 4.4 35 9.77 1
19 41 COLD TURESHEET 1.9 3
1.31 1
19 45 COLO TUBESHEET 3.8 3
1.70 1
19 56 COLD TUBESHEET e.8 19 2.47 3
19 58 COLD TUBESHEET 2.1 5
1.44 1
19 61 COLD TUBESHEET 1.9 6
1.65 1
19 63 COLD TUBESHEET 1.9 3
2.63 1
19 64 COLD TUBESHEET 1.9 9
2.38 1
19 65 COLD TUBESHEIT t.0 13 2.05 1
19 66 COLD TUBESHEET 1.1 4
3.58 1
19 68 HOT 3RD AVB 0.0 8
2.24 1
19 68 COLD TUBESHEET 0.9 It 2.57 1
19 71 COLD TUBESHEET 0.8 27 0.87
SL29 TART OF CT 1986 EDOT CLNtRENT INSPECTIch DATA 4315 NEDHESDAY, MARCH 5. 1996 14 LISTING OF ALL TUBE FLAK 5 FOR STEAN GENERATOR 81 STEAM SENERATOR RON COL 1994 LOC FLAN LOCATION FLAN HEIGHT (INCHES 1 FLAN SIZE (D DEFECT VOLTAGE I
19 72 COLD TUBE 5HEET 3.8 25 3.30 19 73 COLD TUBESHEET 0.9 l'
3.28 1
19 74 COLD TUBESHEET 1.0 14 3.32 1
19 75 COLD TUBESHEET 96 14 1.64 i
1 19 78 COLD TUBESHEET 4.8 4
4.19 l
1 19 79 COLD TUBESHEET 0.8 t{
1.12 j
1 19 80 COLD TUBESHEET 99 y
3 76 1
19 et NOT TUBESHEET 4.7 21 0.78 1
19 83 HOT-IND TSP 40.2 13 1.37 1
19 87 HOT 3RD T5P 23.1 6
2.09 1
19 88 HOT 3RD TSP 21.0 16
$.93 1
19 89 HOT TUBESHEET 1.4 11 0.73 1
20 12 HOT tHD TSP 23.2 4
1.09 g
1 20 36 HOT TUBESHEET 3.7 21 f.81 1
20 24 COLD TUBE 5HEIT 1.2 22 4 55 1
20 25 COLD TUBESHE(T 09 24 2.10 1
20 26 COLO TUDE5H5ET 1.0 25 2.83
-1 20
$7 COLD TUBE 5HEET 41 14 2.21 1
to 29 COLD TUBE 5HEET 4.8 13 1.38 1
20 30 COLD TUBE 5HEET 09 18 1.39 1
20 31 COLD TUBESHEET 3.7 21 2.23 1
1 to 32 NOT TUBE 5HEET W N W. 0.5 11 1.39 1
20 32 HOT tte TSP 13.5 23 4 97 1
20 32 COLD TUBESHEET 1.0 10 1.6T 1
20 33 COLD TUBE 5HEET 0.8 26 1.41 1
20 34 COLD TUBESHEET 0.9 13 3.1$
1 20 35 NOT TUBE 5HEET 0.3 34 0.M 1
20 36 COLD TUBE 5HEET 1.0 0
3.30 1
20 37 COLD TUBE 5HEET 0.9 19 E.23 i
I to 38 COLD TUBESHEET 0.7 15 1.93 1
20 39 HOT TUBESHEET 1.5 10 1.44 I
to 58 NOT 2ND T5P 39.3 8
2.21 1
1 20 60 COLD TUBESHEET 1.4 6
1.07 I
I 20 61 COLD TUBE 5HEET 2.0 8
0.96 1
to 64 COLD TUBESHEET 2.0 16 t.74 1
20 65 COLD TUBE 5HEET 0.8 5
4.43 1
20 66 COLD TUBESHEET 1.2 11 2.36 1
20 67 COLD TUBESHEET 1.0 15 3.07 l
1 to 69 COLD TUBE 5HEET 4.9 19 1.15 1
to 72 COLD TUBESHEET 0.9 11 2.46 1
to 73 COLD TUBESHEET 3.9 25 3.52 1
20 74 COLD TUBESHEET 1.2 11 2.96 1
to 7W HOT TUBE 5HEET 1.2 14 4.46 1
20 75 COLD TUBESHEET 1.1 11 E.16 1
20 76 HOT IST AVB 0.0 4
2.27 1
to 76 COLO TUBE 5HEET 41 11 4 33 1
to 77 COLD TUBE 5HEET 40 23 3.42 1
20 78 HCT TUBE 5HEET 3.8 11 0.92 1
20 78 COLD TUBE 5HEET 0.8 1
3.07 1
to 79 COLD TUBE 5HEET 1.0 5
2.47 1
20 80 COLO TUBE 5HEET 4.9 15 3.32 1
20 91 HOT IST AVB 0.0 1
1.24 1
20 92 HOT TUBE 5HEET 2.3 8
2.08 1
21 17 HOT TUBESHEET 1.0 33 6.67
SL901 ART OF CT 1986 EDDT CtmRENT INSPECTION DATA 0315 WEDNESDAY. MARCH 5. 1996 15 LIST 1HS OF ALL TUBE PLANS FOR STEAM GENERATOR 81 i
STEAM SENERATOR ROM COttAtt LOC FLAN LOCATION FLAN HEIGHT (INCHESI FI "i SIZE (X)
DEFECT VOLTAGE t
I 21 58 HOT 2HD TSP 14.7 It 1.60 1
41 22 COLD TUBESH5ET 4.4 24 0.48 1
El 22 COLD TUBESHEET 0.8 9
1.84 1
21 26 COLD TUBESHEET 4.9 25 1.08 1
21 46 COLD TUBESHEET
- 9 14 0 95 1
tl 27 COLD TUBESHEET 1.2 6
2.55 5
21 20 COLD TUBESHEET 1.1 14 2.48 1
21 29 COLD TUBESHEET 10 9
3.34 1
21 30 COLD TUBESHEET 3.9 28 3 76 1
21 31 HOT TUBESHEET 0.9 9
1.41 1
21 31 COLD TUBESHEET 0.9 14 4.18 1
21 32 COLD TUBESHE(T 10 21 1 71 1
21 33 HOT TUBESH[ET$T 1.2 20 los?
g 21 33 COLD TUBESHE 11 23 1.62 1
21 34 COLD TUBESHEET 93 34 1.5%
i 1
21 34 COLD TUBESHEET 1.0 17 2.20 1
21 35 COLD TUBESHEET 1.0 10
- 3.66 '
1 21 36 COLD TUBESHEET 4.3 23 3.09 1
21 38 COLD TUBESHEET 4.7 15 1.92 1
21 38 COLD TUBESHEET 3.2 4
1.30 1
21 49 COLD TUBESHEET 3.4 7
2.25 1
21 45 COLD TUBESHE5T 3.1 19 8 19 1
El 46 COLD TUBESHEET
' "' b4 'I D T 2.1 15 8.48 1
El 47 HOT IST AVB 0.0 5
1.15
$1 47 HOT 2ND AVB 8.0 1
3.78 1
21 47 COLD TUBESHEET 1.9 4
1.92 21 51 COLD TUBESHEET 1.5 3
0.73 i
1 21 54 HOT TUBESHEET 1.4 45 0.58 1
21 54 COLP TUBESHEET 1.9 8
1.63 1
21 55 COLD TUBESHEET 1.7 22 1.37 1
21 58 COLD TUBESHEET 2.1 6
1.32 1
21 ET COLD TUBESHEET 18 4
1.57 1
t1 60 COLD TUBESHEET 3.1 10 3.59 1
21 64 HOT TUBESHEET 35 9
0.68 1
t) 64 COLD TUBESHE5T 2.1 7
1.93 1
21 63 COLD TU2ESHE$T 3.1 4
2.55 1
21 COLD TUBESHEET 1.4 12 3.92 1
21 s7 COLD TubESHEET 1.0 15 2.04 1
21 69 COLD TUBESHEET 1.0 32 1.30 1
21
?!
COLD TUBESHEET 0.7 14 2.38 1
21 72 COLD TUBESHEET 1.1 6
2.75 1
21 73 COLD TUBESHEET 4.9 11 2.55 1
21 75 COLD TUBESHEET 1.1 14 1.95 1
21 76 COLD TUBESHEET 1.2 13 3.63 1
21 77 COLD TUBESHE5T 1.1 5
3.89 1
21 78 COLD TUBESHEET 0.8 1
2.64 1
21 al NOT TUBESHEET 0.8 14 0.87 1
21 90 HOT 2HD TSP 9.8 5
2.45 1
22 12 NOT TUBESHEET 1.2 9
0.82 1
22 17 HOT TUBESHEET 0.6 11 1.75 1
22 18 HOT -
TUBESHEET 1.2 31 6.82 1
22 21 COLD TUBESHEET 4.9 9
2.99 1
22 24 COLD TUBESHEET 0.9 18 3.10 1
22 25 COLD TUBESHEET 1.2 18 3.70
SLR9 TART OF CT 190$ EDDT CURRENT INSPECTION DATA 0:15 NEDHESDAT. MARCH 5. 1986 16 LISTINS OF ALL TLBE FLANS FOR STEAM SEHERATOR 81 STEAM SENERATOR ROM COL 1994 LCC FLAN LOCATION FLAN HEIGHT (INCHESI FLAN SIZE (XI DEFECT VDLTASE I
22 26 COLD TLBESHEET 1.4 4
8.94 I
22 27 COLD TUBESHEET
!.3 It 2.65 1
1 It 24 COLD TUBESHEET 1.2 14 3.94 1
22 29 COLD TUBESHEET 4.0 15 5.28 1
22 39 COLD TUBESHf5T 0.9 25 4.60 1
22 3)
COLD TUBESHEET 0.7 I?
4.41 1
22 32 HOT TUBESHE$T 4.8 19 0.81 1
22 32 COLD TUBESHEET 1.1 22 2.79 I
22 33 HOT TUBESHEET 0.9 14 1.19 l
1 22 33 COLD TUBESHEET 1.0 15 3.92 1
22 35 NOT TUBESME$T 32 4
1.69 I
22 35 COLD TUBESHEET 40 3
2.09 I
I tt 36 HOT TUBESHE$T S.5 14 0.75 g
I 22 34 COLD TUBESHERT 3.5 14 5 79 i
1 22 37 COLD TUBESHEET 0.6 t.97 1
22 36 NOT TUBESHEET 1.3 15 1.67 1
22 38 COLD TUBESHEET 9.6 23 1.92 1
22 38 COLD TUBESHEET 2.2 2
J.13 1
22 40 HOT TUBESHEET 42 21 1.61 l
1 22 41 COLD TUBE SHEET 2.1 17
't.75 i
1 22 45 COLD TUBESHEET 35 4
E.54 1
22 47 HOT IST AVB 90 1
3.59 1
22 47 COLD TUBESHEET
'9'l"'dINl' !.8 2
$.00 1
22 49 COLD TUBESHEET 2.0 le 1.27 I
22 54 HOT 3RD TSP 23.3 4
1,91 1
22 58 COLD TUBESHEET 1.9 5
1.24
{
22 60 COLD TUBESHEET 1.2 11 2.21 i
I 22 61 COLD TUBESHEET 1.9 4
1.90 1
1 22 63 COLD TUBESHEET 3.7 8
2.07 8
22 64*
COLD TUBESHEET 1.9 12 4 68 1
22 65 COLD TUBESHEET t.2 5
1.17 1
22 66 COLD TUBESHEET 1.3 le 3.05 1
22 67 COLD TUBESHEET tot 6
3.68 1
22
,69 COLD TUBESHEET 1.0 12 3 60 1
22 71 COLD TUBESl!EET 0.9 11 2.31 1
22 72 COLD TUBESHEET 1.2 19 4 75 1
22 73 COLD TUBESHEET 97 12 2.50 1
22 74 COLD TUBESHEET 3.1 10 2.64 1
22 75 COLD TUBESHEET 0.3 26 2.06 1
22 75 COLD TUBESHEET 4.6 7
3.93 1
22.
76 COLD TUBESHEET 1.1 11
}.23 1
22 80 COLD TUDESHEET 0.9
}.33 1
23 22 COLD TUBESHEET 1.0 13 1.45 1
23 22 COLD TUBESHEET 2.3 9
4.60 1
23 24 s COLD TUBESHEET 3.9 17 3.33 1
23 25 '
COLD TUBESHEET 1.0 19 3.65 9
3.70 1
23 26 COLD TUBESHEET 1.1 1
23 27 COLD TUBESHEET 1.1 le 3.41 1
23 28 COLD TUBESHEET 1.3 19 3.93 1
23 29 COLD TUBESHE&T 1.4 26 5.01 1
23 29 COLD TUBE!HEET 3.1 7
1.10 1
23 30 COLD TUBESHEET 1.3 10 5.86 1
23 31 COLD TUBESHEET 4.9 22 5.05 1
23 32 COLD TUBESHEET 1.3 10 4.55
StemART OF CT 1966 ED0Y CtNIRENT INSPECTICH DATA 0:15 NEDHESOAT, MARCH 5. 1966 17 LISTING OF ALL YtBE FLANS FOR STEAM SENERATOR 81 STEAM GENERATOR ROM C0tt#94 LOC FLAN LOCATION FLAN HEIGHT IINCHESI FLAN SIZE (%I DEFECT VOLTAGE 1
23 33 NOT TUBE 5HEET 3.7 16 0.90 1
23 33 COLD TUBE 5HEET 1.2 12 3.29 1
23 34 COLD TUBESHE5T 0.5 19 1.49 1
23 34 COLD TUBESHEET 1.1 14 2.62 1
23 36 HOT TUBESHEET 4.0 14 8 61 1
23 36 COLD TUBESHE5T 40 22 4 69 1
23 37 COLD TUBESHEET 0.2 13
).22 1
23 37 COLD TUBESHE5T 4.5 7
1.90 t
23 38 HOT TUBE 5HEET 95 24 1.09 1
23 38
, NOT TUBESHEET 1.0 15 1.56 1
23 38 COLD TUBESHEET 0.8 18 1.93 1
23 38 COLD TUBESHEET 3.3 8
4 66 8
t) 39 '
COLD TUBESHEET
$.2 15
.56 3
33 40 HOT TUBESHEET 4.8 6
.65 1
23 40 HOT TUBE 5HEET 4.6 1
.90 1
23 40 COLD TUBESHEET 3.4 11
.58 1
23 41 NOT TUBESHEET 8.9 22 1.37 1
23 41 NOT TUBE 5HEET 1.7 22 0.59 1
23 41 COLD TUBESHEET 2.1 5
1.57 1
23 42 NOT TUBESHEET 3.1 13 2.55 1
23 53 COLD TUBESHEET 1.5 4
2.30 1
23 58 COLD TUBESHEET
. 99 1
3.02 1
23 58 COLD TUBE 5HEET
" 4 f "" 9 0 ' ' t. 0 6
1.46 4
33 61 COLD TUBE 5HEET 3.1 8
$.35 1
23 62 NOT TUBE 5HEET S.6 35 8 13 1
1.
23 64 COLD TUBE 5HEET 0.9 8
8.08 j
1 23 65 COLD Tun;%HEET 1.0 31
- 3. 36 1
23 65 COLD TUBtSHEET 3.1 7
8 39 i
1 23 66 COLD TUBESHEET 1.5 6
3.90 4
23 67 COLD TUBE 5HEET 1.2 13 1.99 1
23 68 HOT TUBESHEET 3.5 10 1.64 1
1 23 68 COLD TUBESHEET 1.0 19 0.93 i
1 23 69 COLD TUBE 5HEET 1.0 5
2.39 1
33 71 HOT TUBESHEET 0.4 8
1.21 1
23 71 COLD TUBE 5HEET 0.8 14 8 81 1
23 72 COLD TUBESHEET 4.8 15 8.77 1
23 73 COLD TUBE 5HEET 3.1 14 3.71 1
23 74 COLD TUBESHEET 3.2 1
3.89 1
23 75 COLD TUBESHEET 0.4 11 3.32 1
23 75 COLD TUBESHEET 3.7 4
1.76 1
23 76 COLD TUBE 5HEET 4.4 10 1.60 1
23 90 NOT 2ND TSP 37.7 7
2.03 1
24 12 NOT 2HD TSP 22.9 6
1.49 1
24 20 NOT 2HD TSP 17.9 31 1.43 1
24 21 NOT 2ND TSP 3.0 5
1.49 1
24 25 COLD TUBELHEET 1.0 22 3.12 1
24 26 COLD TUBE 5HEET 1.2 8
3.95 1
24 27 COLD TUBE 5HEET 1.4 17 3.83 g
1 24 28 COLD TUBE 5HEET 1.3 19 3,40 1
24 29 COLD TUBESHEET 1.4 20 3.07 1
24 30 COLD TUBESHEET 1.7 20 0.47 1
24 31 COLD TUBE 5HEET 1.2 14 2.43 1
24 32 COLD TUBE 5HEET 1.4 22 1.73 1
24 34 COLD TUBESHEET 1.0 14 4.37
St#01 ART OF CT 1986 EDDT CtmRENT INSPECTION DATA 0:15 NEDHESD;T. MARCH 5. 1906 18 LISTING OF ALL TISE FLAks FOR STEAM SENERATOR 81 STEAM GEMRATOR ROM COL 1994 LOC FLAN LOCATION FLAN HEIGHT (INCHES)
FLAN SIZE (X)
DEFECT VOLTAGE i
1 24 35 COLD TUBESHEET 0.7 17
(.79 1
24 35 COLD TUBESHEET 2.8 7
1.63 1
24 3$
NOT TUBESHEET 3.6 15 1.27 1
24 36 COLD TUBESHEET 4.9 21 3.91 1
24 37 COLD TUBESHEET 3.6 12 1.76 1
24 37 COLD TUBESHEET 1.0 7
3.27 1
44 38 HOT TUBESHEET 0.4 18 1.61 1
24 38 COLD TUBESHEET 3.8 6
3.36 1
24 59 COLD TUBESHEET 3.9 It 2.24 I
24 40 NOT TU3ESHEET 1.1 11 1.64 l
'l 24 40 COLD TUBESHEET 40 It 2.72 1
24 41 HOT TUBESHEET 0.6 17 2.12 i
l 1
24 41 COLD TUBESHEET 1.0 17
$.02 g
)
24 41 COLD TUBESHEET 2.3 8
5 56 i
1 24 44 HOT TUBESHEET 0.7 25 1.49 24 45 HOT TUBESHEET 1.5 9
1.15 1
24 46 HOT 2ND TSP 3.3 46 1.93 1
24 47 HOT IST AVB 0.0 7
1.48 i
1 24 53 COLD TUBESHEET 1.5 1
2.04 I
1 24 55 HOT TUBESHEET 0.7 8
(.18 1
24 57 COLD TUBESHEET 1.3 16 2.00 1
24 57 COLD TUBESHEET 2.1 5
2.43 i
1 24 64 COLD TUBESHEET
Fi '"E'9" 2.0 11 1.85 1
1 24 65 COLD TUBESHEET 1.0 11 3.12 i
1 24 66 COLD TUBESHEET 1.3 6
2.91 1
24 67 COLD TUBESHEET 0.9 4
2.81 1
24 69 COLD TUBESHEET 1.0 le 2.64 1
24 70 COLD TUBESHEET 1.0 12 4.16 i
1 24 71 COLD TUBESHEET 1.1 13 2.24 1
24 72 COLD TUBESHEET 3.5 40 1.39 1
24 72 COLD TUBESHEET 1.1 5
2.86 1
24 73 COLD TUBESHEET 1.1 2
3.53 1
1 24 74 COLD TUBESHEET 1.3 7
1.81 1
24 75 COLD TUBESHEET 1.0 9
1 70 1
24 78 COLD TUBESHEET 1.2 6
8.93 1
1 24 80 NOT TUBESHEET 2.0 21 9 64 1
25
$2 HOT 2ND TSP 28.1 5
2.26 1
I 1
25 20 NOT 2ND TSP 18.3 22 1.61 1
25 20 NOT 2ND TSP 19.7 32 1.07 1
25 23 HOT IST TSP 13.7 32 1.24 1
25 25 COLD TUBE 5HEET 0.8 18 2 40 i
1 25 26 COLD TUBESHEET 1.4 7
4 83 j
1 25 27 COLD TUBESHEET 0.9 13 3.27 j
1 25 27 COLD TUBESHEET 3.2 le 1.63 1
25 to COLD TUBESHEET 1.5 16 4 97 1
25 Zv COLD TUBESHEET 1.3 29 4 01 j
1 25 39 COLD TUBESHEET 3.4 5
4 92 1
25 30 COLD TUBESHEET 1.0 24 2.25 1
25 30 COLD TUBESHEET 1.8 8
1.59 I
1 25 31 COLD TUBESHEET 0.9 20 1.63 1
25 32 COLD TUBESHEET 1.0 17 2.72 1
25 34 COLD TUBESHEET 1.3 16 2.49 1
25 35 COLD TUBESHEET 1.0 14 6 15 1
25 36 COLD TUBESHEET 0.7 19 3.31
StAttART OF CT 1986 EDDT CL5tRENT INSPECTION DATA 0:15 NEDHESOATo MARCH 5. 1996 19 LISTING OF ALL TUBE FLAWS FOR STEAM GENERATOR 81 STEAN GENERATOR RON COLL 204 LOC FLAN LOCATION FLAN HEIGHT IINCHESI FLAN SIZE EX)
DEFECT VOLTAGE i
j 25 38 HOT TUBESHEET 3.5 15 0.93 1
25 38 COLD TUBESHEET
$.0 15 2.06 I
25 39 HOT TUBESHEET 4.4 43 1.49
.I 2
25 39 HOT TUBESHEET 4.7 17 5 63 i
1 25 39 COLD TUBESHEET 0.3 16 1 52 1
25 39 COLD TUBESHEET 1.0 It 2,07 1
25 40 NOT TUBESHgET 3.1 22 1.44 1
25 40 HOT TUBESHEET 0.9 17 1.41 1
25 40 COLD TUBESHEET 3.9 10
$.29 1
25 41 HOT TUBESHEET 3.2 16 1.74 1
25 41 COLD TUBESHEET 0.7 22 0.91 1
25 46 HOT TUBESHEET 1.4 21 E.52 1
25 47 COLD TUBESHEFT 1.5 7
$.15 g
1 35 55 COLD TUBESH$ET 1.9 4
$.11 1
25 57 COLD TUBESHEET 2.0 4
$.09 I
15 62 COLD TUBESHEET 3.7 12 1.10 I
1 25 63 COLD TUBESHEET 4.7 16 3.64 1
25 64 COLD TUBESHEET 0.9 11 2.42 1
25 64 COLD TUBESHEET 1.0 4
E.62 1
25 70 COLD TUBESHEET 1.4 5
4.02 1
25 71 COLD TUBESHEET 1.1 11 3.04 i
1
$5 73 COLD TUBELHEET 1.3 4
2.90 1
25 74 COLD TUBESHEET
' 'F 8'"d I k " 1.3 5
2.44 1
25 76 HOT 4TH AVS 0.0 14
$.23 1
$5 66 HOT 3RD TSP 7.8 3
1.45 1
25 46 HOT IST AVB 0.0 5
3.62 1
25 91 HOT 3RD AVB 0.0 4
1.18 1
25 92 HOT 3R0 TSP 15.0 8
0.93 1
26 It NOT 2ND TSP 5.5 35 1.37 j
1 26 21 HOT 2ND TSP 4.0 43 1.55 1
26 21 NOT 2HD TSP 12.2 17 2.29 l
1 26 27 COLD TUBESHEET 3.5 12 0.99 l
1 26 28 COLD TUBESHEET 1.2 8
3.23 1
1 26 29 COLD TUBESHEET 1.1 Il 2.62 l
1 26 32 COLD TUBESHEET 1.5 le 2.98 1
1 26 34 COLD TUBESHEET 1.4 14 2.94 1
26 35 COLD TUBESHEET 1.5 15 3.90 1
26 36 COLD TUBESHEET 3.2 19 3.42 i
1 26 36 COLD TUBESHEET 1.0 14 3.63 l
1 26 38 COLD TUBESHEET 1.0 10 4 37 1
26 39 HOT TUBE 5HEET 0.7 5.
1.41 1
26 39 COLD TUBESHEET 0.8 20 1.02 l
1 26 40 HOT TUBESHEET 0.4 11 2.10 l
~1 26 40
- COLD TUBESHEET 0.8 17 1.67 l
1 26 45 HOT TUBESHEET 3.4 19 1.39 1
26 45 COLD TUBESHEET 0.5 4
2.52 1
26 46 HOT TUBESHEET 1.0 23 2.25 1
26 47 COLD TUBESHEET 1.8 2
3.15 1
26 55 COLD TUBESHEET 1.1 9
1.20 1
26 64 COLD TUBESHEET 1.1 2
3.69 i
1 26 68 COLD TUBESHEET 1.4 4
2.54 1
26 69 COLD TUBESHEET 0.5 le 1.24 1
26 72 HOT TUBESHEET 2.8 11 0.83 1
26 73 COLD TUBESHEET 1.2 12 3.17
\\
StatlARY OF CT 1986 EDDY CURRENT INSPECTION DATO S:15 NEDNESDAYo MANCH 5e 1986 28 LISTING OF ALL TLSE FLAWS FOR STEAN GENECATOR 81 STEAM SENERATOR RON COL 1998 LOC FLAN LOCATIDH FLAN HEIGHT IINCHES)
FLAN SIZE (%)
DEFECT VOLTA 8E 1
26 74 COLD TUBE 5HEET 1.0 It 2.49.
1 26 75 COLD TUBE 5HEET 1.0 7
1.36 1
26 75 COLD TUBE 5HEET 3.8 5
1.03 1
26 82 NOT 3RD TSP 1.0 23 1.02 1
26 86 HOT IST AVB.
0.0 16 1.80 1
26 49 HOT TUBE 5HEET 3.9 5
1.73 1
36 92 HOT 3RD TSP 6.3 11 1.38 1
27 13 HOT 2ND T5P 9.7 37 2.56 1
27 33 NOT 2HD TSP 9.4 93 0.68 1
27 28 COLD TUBE 5HEET 1.8 6
2.63 1
27 30 COLD TUBE 5HEET l.1 9
1.54 1
27 31 COLD TUBE 5HEET 3.5 le 1.88 1
27 32 COLD TUBE 5HEET 0.5 1
2.70 g
1 27 35 COLD TUBE 5HEET 1.5 7
4.27 1
27 36 COLD TUBESHEET 1.0 3
1 67 1
27 39 COLD TUBE 5HEET 1.4 6
1 48 1
27 40 COLD TUBE 5HEET O.3 17 0 75 1
27 40 COLD TUBE 5HEET 1.2 12 1.63 1
27 45 COLD TUBESHEET 4.5 19 0.77 1
27 49 COLD TUBE 5HEET 4.8 5
2.05 1
27 56 HOT TUBE 5HEET 0.8 12 2.57 1
27 68 COLD TUBE 5HEET
. 1.6 1
3.13 1
27 69 COLD TUBE 5HEET
' "" i " t k" 1.4 28 1.21 1
27 73 COLO TUBESHEET 1.2 8
2.54 1
27 74 COLD TUBE 5HEET 8.6 to 1.45 1
27 76 COLD TUBE 5HEET 4.8 29.
1 00 1
28 21 HOT 3RD TSP 6.8 18 1.24 1
28 22 HOT 3RD TSP 9.8 31 0.69 1
28 23 NOT 2ND TSP 6.5 42 8.54 1
28 24 HOT 2ND TSP 7.0 to 1.60 1
28 28 COLD TUBESHEET 3.8 9
1.93 1
28 29 COLD TUBE 5HEET 1.0 8
2.21 1
28 30 COLD TUBESHEET 9.4 28 1.28 1
28 34 COLD TUBE 5HEET 1.2 It 2.26 1
28 32 COLD TUBE 5HEET 3.4 6
2.38 1
28 33 COLD TUBE 5HEET 4.4 9
1.66 1
28 34 COLD TUBE 5HEET 1.7 20 1.18 1
28 35 HOT TUBE 5HEET 0.5 32 8.47 1
28 35 COLD TUBE 5HEET 1.3 18 4.32 1
28 36 COLO TUBE 5HEET 1.3 17 4.13 1
28 37 COLD TUBE 5HEET 3.4 19 2.54 1
28 38 COLD TUBE 5HEET 3.4 13 2.56 3
1 28 39 COLD TUBE 5HEET 1.5 12 1.25 1
28 40 COLD TUBE 5HEET 1.1 14 1.28 1
28 41 COLD TUBESHEET 1.2 23 1.09 1
28 42 COLD TUBESHEET 1.0 5
2.43 1
28 45 COLD TUBE 5HEET 1.0 14 3.22 1
28 49 COLD TUBE 5HEET 3.4 11 2.59 1
28 52 COLD TUBE 5HEET 3.0 25 0.52 1
28 54 COLD TUBE 5HEET 1.6 8
2.15 1
28 55 COLD TUBE 5HEET 4.8 23 1.00 1
28 62 COLD TUBE 5HEET 1.1 17
~2.19 1
28 62 COLD TUBE 51tEET 1.7 5
1.11 1
28 63 HOT IST AVB 0.0 1
2.12
SLRetART OF CT 1986 EDOT CtmRENT INSPECTION CATA 0:15 NEDHE30AT. MARCN 5. 1986 21 LISTING OF ALL TLSE FLAWS FOR STEAM SENEGATOR 81 STEAM SENERATOR ROM COLL 298 LOC FLAN LOCATION FLAN HEIGHT (INCHESI FLAN SIZE (%)
DEFECT VOLTA 8E 1
28 65 COLD TISESHEET 1.3 4
2.59 1
28 68 COLD TUBESHEET 1.3 I4 2.09 1
28 69 COLD TUBE 5HEET 1.5 I4 2.68 1
28 71 COLD TUBE 5HEET 1.1 14 2.86 1
28 72 COLD TUBESHEET 1.1 22 2.02 1
to 47 HOT 2ND T5P 9.9 15 1.64 1
28 88 HOT IST AVB 4.0 3
3 7$
1 29 47 HOT END TSP 5.8 54 1.$3 1
29 17 HOT 2ND TSP 9.0 22 1.53 1
29 31 NOT RND TSP 13.2 39 1.21 1
39 23 HOT 22 TSP 3.0 34 0.55 1
29 23 HOT END TSP 67 17 1.34 1
49 34 NOT 2ND TSP 4$.5 12 0.64 g
1 29 25 NOT 2ND TSP 3.6 32 0.85 1
29 30 COLD TUBESHEST 3.3 IS 0 69 i
I 19 31 NOT TUBE 5HEET 4.7 11 0.47 1
29 31 COLD TUBE 5HEET 8.4 14 1.33 1
29 32 COLD TUBE 5HEET 3.6 19 2.66 1
29 32 COLD TUBE 5HEET 1.4 9
2.74 1
29 33 NOT TUBE 5HEET 4.6 le 1.33 l'
29 33 COLD TUBE 5HEET 3.5 7
1.74 1
29 36 COLD TUBE 5HEET 0.5 8
2.23 1
39 37 COLD TUBE 5HEET
' "' b ' ^ IN' O.5 9
2 57 1
29 34 COLD TUBE 5HEET 36 9
2.39 1
29 39 COLD TUBE 5HEET 1.1 13 0 72 1
29 39 COLD TUBE 5HEET 3.2 13 1.00 1
29 40 COLD TUBE 5HEET 1.4 6
1.43 1
29 41 COLD TUBE 5HEET 1.0 26 1.86 1
29 42 COLD TUBE 5HEET 0.9 5
2.74 1
29 43 COLD TUBE 5HEET 1.1 7
2.14 1
29 46 COLD 7tBE5HEET 4.6 4
3.04 1
29 47 COLD TUBE 5HEET 0.5 9-3.03 1
29 49 COLD TUBE 5HEET 0.6 19 1.69 1
29 51 COLD TUBE 5HEET 0.7 13 2.06
'i 1
29 55 COLD TUBE 5HEET 1.1 11 1 70 l
1 29 68 COLD TUBE 5HEET 1.0 9
2.57 1
29 69 COLD TUBE 5HEET 1.0 18 3.41 1
29 71 COLD TUBE 5HEET 1.1 19 1.06 j
1 29 76 HOT 2ND T5P 16.0 6
2.00 1
19 80 HOT 2ND TSP 7.7
?
).K i
1 30 13 HOT TUBESHKET 4.4 4
1.42 1
30 13 NOT 2ND TSP 22.7 11 2.30 i
1 30 13 HOT 4TH AVB 0.0 9
2.32 1
30 13 COLD TUBE 5HEET 27.5 18 1.24 1
30 17 HOT TUBE 5HEET 1.7 15 2.75 1
30 17 HOT 4TH AVB 0.0 4
3.99 1
30 21 HOT 2ND TSP 12.6 41
}.09 1
30 23 HOT 2ND TSP 8.2 18 3 22 1
30 24 HOT END TSP 5.9 36 2.71 1
30 25 NOT 2ND TSP 7.2 27 1.35 1
30 27 COLD TUBE 5HEET 3.5 6
1.89 1
30 28 HOT END TSP 15.0 36 2.64
- 1 30 30 COLD TUBE 5HEET 3.6 18 0.89 i
30 32 NOT END TSP 9.3 42 1.39 i
St#91 ART OF Ci 1986 EDDT CamRENT INSPECTION DATA 0 15 WEDHE50 ate MARCH 5e 1986 22 LIST 1HB 0F ALL TLSE FLAWS FOR STEAM SENERATOR 81 STEAM SENERATOR ROM Cott#94 LOC FLAN LOCATION FLAN HEIGHT (INChESI FLAN SIZE (%)
DEFECT VOLTAGE 1
30 32 COLD TUBE 5HEET 1.4 9
2.31 1
30 33 COLD TUBESHE&T 3.6 54 S.39 1
10 33 COLD TUBE 5HEET 3.5 33 2.64 1
30 34 COLD TUBE 5HtET 4.4 19 3.24 1
30 34 COLD TUBE 5HEET 2.0 15 1.31 1
30 35 COLD TUBE 5HEET 32 22 4 64 I-30 35 COLD TUBE 5HEET 3.9 16 3 41 1
30 36 HOT TUBE 5HEET 3.5 40 0 41 1
30 36 COLD TUBE 5HEET 3.5 le 3.99 1
30 36 COLD TUBE 5HEET 3.6 8
2.39 1
30 38 HOT TUBE 5HEET 0.6 11 1.51 3
30 38 COLD TUBE 5HEET 1.7 26 0.93 1
30 38 COLD TUBE 5HEET 3.3 le 1.97 g
I-30 39 COLD TUBE 5HEET 1.3 15 3.57 1
30 40 COLD TUBE 5HEET 1.2 17 3.44 1
30 40 COLD TUBE 5HEET 3.2 10 2.64 1
30 41 COLD TUBE 5HEET 1.1 5
3.10 1
30 42 COLD TUBE 5HEET 0.9 21 1.58 1
30 42 COLD TUBE 5HEET 3.1 15 3.32 1
30 42 COLD TUBE 5HEET 3.0 7
2.21 1
30 43 COLD TUBE 5HEET 0.9 33 1.16 1
30 43 COLD TUBE 5HEET 1.2 7
1.59 1
30 44 COLD TUBE 5HEET "d I'*'2"E 1.0 7
0.95 3
30 45 COLD TUBE 5HEET 2.5 9
2.13 1
30 49 COLD TUBE 5HEET 4.6 33 0.74 1
30 52 COLD TUBE 5HEET 4.7 4
2.75 1
30 54 COLD TUBE 5HEET 0.7 16 2.66 1
30 55 COLD TUBE 5HEET I.0 15 3.32 l'
30 57 HOT TUBE 5HEET 4.6 14 1.70 I-30 57 COLD TUBE 5HEET 1.0 le 4 82 1
30 58 COLD TUBE 5HEET 0.4 26 1.92 1
30 58 COLD TUBE 5HEET 1.0 5
2.09 I
30 40 NOT TUBE 5HEET 3.6 19 4 29 1
30 60 HOT TUBE 5HEET 2.7 2
1.96 1
30 60 COLD TUBE 5HEET 0.7 2.39 1
30 64 NOT 2HD AVB 0.0 18 0.38 1
30 64 COLD TUBE 5HEET 0.3 9
1.05 4
1 30 65 COLD TupE5HEET 1.5 12 4 23 1
30 66 COLD TUBE 5HEET 3.2 11 t.96 1
30 68 COLD TUBE 5HEET 3.9 13 1.81 1
30 69 COLD TUBE 5HEET 1.0 8
1.81 1
30 71 NOT 2ND TSP 23.5 le 1.44 1
30 71 COLD TUBE 5HEET 1.2 19 3.13 1
30 76 HOT TUBE 5HEET 2.1 6
0.62 1
31 21 HOT 2ND T5P 19.1 38 0.05 2
31 te NOT 2ND TSP 8.5 33 1.55 1
35 34 COLD TUBE 5HEET 1.5 21 0.93 1
31 35 COLD TUBE 5HEET 3.6 19 0 57 1
31 36 COLD TUBE 5HEET 1.3 11 4 01 1
31 38 COLD TUBE 5HEET 1.6 2
1.44 1
31 40 HOT TUBE 5HEET 0.9 13 1.47 1
31 40 COLD TUBE 5HEET 0.9 15 1.02 1
31 40 COLD TUBE 5HEET 3.2 7
1,66 1
31 45 COLD TUBE 5HEET 1.2 2
2.16
SL89 TART OF CT 1906 EDDT CURRENT INSPECTION DATA 0:15 NEDHESOAT. MARCN 5, 1986 23 LI!TIHS OF ALL TUBE FLAWS FOR CTEAM SEMEZATOR el STE/.M SE9ERATOR 50W COL 1298 LOC FLAN LOCATION FLAN HEIGHT IINCHES)
FLAN SIZE (XI DEFECT VOLTA 8E 1
31 46 COLD TUBESHEET 07 23 1.18 1
31 50 COLD TUBESHEET 0.9 12 1.b6 1
31 53 COLD TUBE SHEET 0.7 9
2.35 1
31 55 COLD TUBESHEET 0.8 lt 2.60 1
31 56 COLD TUBESHEET 0.4 14 1.96 1
31 57 COLD TUBESHEET 1.0 7
4 93 1
31 58 COLD TUBESHEET 1.0
(
!.14 1
31 59 COLD TUBESHEET 0.9 IF 4.56 1
11 62 COLD TUBESHEET 0.9 l.91 1
31 63 COLD TUBESHEET 12
(.63
\\
1 31 66 COLD TUBESHEET 1.0 2.27 1
31 74 NOT TUBESHEET 0.6 It 3 23 1
31 75 NOT TUBESHEET 0.8 1.
3 12 3
l 1
31 75 HOT 3RD AVE 0.0 4
.30 1
31 79 HOT IND TSP 75 11
.43 i
1 31 44 HOT 4TH AVB 0.0 3
H.30 1
31 45 HOT IST AVB 8.0 3
f.75 3
31 88 HOT 2HD TSP 3.4 40 2.53 1
32 22 POT 2ND TSP 3.8 38-1.04 1
32 25 NOT IND TSP 22.9~
5 1.68 1
32 34 COLD TUBESHEET 1.3 17 1.30 32 36 COLD TUBESHEET 1.3 6
4.61 i
1 33 37 HOT TUBESHEET D'II6 't.7 7
1.13 1
32 37 COLD TUBESHEET 1.2 11 5 23 1
32 39 COLD TUBESHEET 1.4 14 1 72 1
32 40 COLD TUBESHEET 0.9 10
(.14 I
32 42 COLD TUBESHEET 2.8 5
4 96 l
1 32 43 COLD TUBESHEET 1.2 7
2.06 i
1 32 45 COLD TUBESHEET 1.2 8
2.28 j
1 32 47 COLD TUBESHEET 0.5 11 2.51 1
32 49 COLD TUBESHEET 0.7 4
2.78 j
1 32 50 COLD TUBESHEET 0.8 25 1.29 1
32 50 COLD TUBESHEET 1.8 9
1.69 l
1 32 51 COLD TUBESHEET 0.6 17 2.39 1
32 51 COLD TUBESHEET 1.2 9
1.26 1
32 52 COLD TUBESHEET 0.4 6
2.61 1
32 53 COLD TUBESHEET 0.6 8
2.62 l
1 32 54 COLD TUBESHEET 1.0 10 2.52 1
32 55 COLD TUBEC. LEET 3.9 5
2.53 1
32 56 COLD TGBESHEET 3.9 20 2.39 i
1 1
32 57 COLD TUBESHEET 1.0 23 1.98 l
1 32 58 COLD TUBESHEET 1.0 9
2.53 1
32 59 CCLD TUBESHEET 0.4 17 2.44 1
32 60 COLD TUBESHEET 0.9 19 1.44 l
1 32 62 COLD TUBESHEET 1.0 7
~1.72 1
32 63 COLD TUBESHEET 1.0 11 2.16 1
32 66 HOT IST AYB 0.0 8
0.98 1
32 66 HOT IND hvB 0.0 5
3.06 i
1 32 66 NOT 4Tu AVB 0.0 2
2.40 1
32 72 HOT TJBESilEET 2.2 5
1.45 1
32 72 NOT 3RD TSP 33.8 3
1.21 1
32 76 HOT 3RD AVB 0.0 5
1.77 1
32 83 HOT IST AVB 0.0 12 2.52 1
32 84 HOT TUBESHEET 1.3 5
2.71 m
e
SID91 ART OF CT 1986 EDDT C' BRENT INSPECTION DATA 8:15 NEDNESDAT, MARCH 5. 1986 24 LISTINB OF AL1 'UBE FLAWS FOR STEAN C'.(3]ATOR 81 l
l STEAM SENERATOR ROW COL 1998 LOC FLAN LOCAT!f",
FLAN NEIGHT (INCHESI FLAN SIZE (X)
DEFECT VOLTAGE 1
33 34 COLD TUBESHEET 1.8 15 1 79 1
33 35 COLD TUBESHEET 1.3 21 2.93 1
33 36 COLD TUBESHEET 1.3 33 1.87 1
33 38 COLD TUBE 5HEET 2.8 le 9.93 1
33 39 COLD TUBESHEET 1.3 11 1.50 l
1 33 45 COLD TUBE 5HEET 3.6 7
2.18 l
1 33 46 COLD TUBE 5HEET 30 11 0.95 I
1 33 44 COLD TLSESHE$T 4.6 9
4.57 i
33 49 COLD TUBE 5HEET 0.8 11 3.71 1
33 50 COLD TUBE 5HEET 3.1 24 1.73 l
1 33 51 COLD TUBESHEET 4.7 14 4.15 33 52 COLD TUBESHEET 0.7 13 3.17 l
1 33 53 COLD TUBESHEET 0.7 58 2.71 g
1 33 55 COLD TUBESHEET 3.9 18 3.36 33 56 COLD TUBESHEET 1.0 26 0.89 i
33 57 COLD TUBESHEET 1.8 24 1.38 1
33 58 COLD TUBE 5HEET 8.9 21 1.12 1
33 58 COLD TLSESHEET 3.5 15 1.00 4
l 1
33 59 COLD TUBE 5HEET 4.4 17 2.29 1
33 61 COLD TUBE 5HEET 4.6 8
2.11 1
33 63 COLD TUBE 5HEET 9.6 5
0.97 1
33 65 NOT 2ND AVB 0.0 21 1.27 1
33 69 HOT 2ND TSP
"' '" " I4 27.1 5
3.56 l
1 33 7e NOT 2HD AVB 4.0 2
2.95 1
33 70 NOT 3RD AVB 4.0 18 2.10 1
33 82 NOT 3RD AVB S.0 3
3 77 1
34 15 HOT 4TH AVB 0.0 3
2.13 1
34 17 HOT 4TH AVB 0.0 9
3.45 1
34 22 HOT 2ND TSP 7.1 27 8 65 1
34 23 HOT 2ND TSP 7.3 17 0.99 1
34 24 NOT 2ND TSP 22.5 7
9.99 1
34 29 HOT 2ND TSP 15.8 32 0.85 1
34 35 COLD TUBE 5HEET 3.3 14 0.68 1
34 37 COLD TUBESHEET 3.8 14 2.85 1
34 38 COLD TUBESHEET 3.8 13 2.25 1
34 39 COLD TUBE 5HEET 3.7 17 9.96 1
34 41 COLD TUBE 5HEET 8.7 17 1.44 1
34 44 HOT 3RD TSP 8.8 28 2.34 1
34 45 COLD TUBE 5HEET 8.5 It 1.12 1
34 47 COLD TUBE 5HEET 8.5 6
2.05 1
34 49 COLD TUBE 5HEET 0.4 1
3.38 1
34 50 COLD TUBE 5HEET 2.8 11 1.90 1
34 51 COLD TUBE 5HEET 3.4 32 0.76 1
34 51 COLD TUBE 5HEET 2.3 6
1.19 1
34 54 COLD TUBE 5HEET 0.7 22 1.01 1
34 55 HOT TUBESHEET 3.9 23 2.55 1
34 58 COLD TUBESHEET 8.5 11 1.51 1
34 76 HOT 3R0 AVB 0.0 6
3.46 1
34 81 NOT 4TH AVB 8.0 16
$.23 1
34 85 NOT IST AVB 0.0 9
2.97 4
1 34 86 HOT IST AVQ 0.8 3
3.45 1
35 23 HOT 2HD TSP 5.2 31 1.69 1
35 24 HOT 2HD TSP 4.8 43 1.66 1
35 26 HOT 3RD TSP 1.5 42 0.66
St99tARY OF CT 1986 EDOT CtmRENT INSPECTION DATA 8:15 NEDHESOAYo MARCW 5. 1986 25 LISTIts OF ALL TUDE FLAWS FOR STEAN GEMCATER 81 STEAN GENERATOR SOM COLL 998 LOC FLAN LOCATION FLAN HEIGHT (INCHES 3 FLAN SIZE (2)
DEFECT VOLTAGE 1
35 27 HOT 3po TSP 8.7 29 9.79 1
35 24 HOT 3R0 TSP 4.9 24 1.47 1
35 32 NOT tte TSP 19.5 48 1.16 1
35 34 NOT TtBESHEET 10 25 1.25 1
35 34 COLD TUBESHEET 8.6 3
1.28 1
35 38 COLD TimESHEET 9.4 31 8.46 i
1 35 39 HOT tie AVB 4.0 1
3.84 l
1 35 39 COLD TUBESHEET 8.3 16 1.66 1
35 43 COLD TUBESHEET 1.7 le 1.27 1
35 51 COLD TUBESHEET 2.6 9
1.67 1
35 6)
NOT IST AVB S.8 2
2.01 1
35 64 COLD TLSESHEET 1.1 5
1.94 1
35 6$
HOT tte AVB 0.0 26 1 74 g
1 35 66 COLD TUBESHEET 1.2 11
$.42 1
35 69
@T IST AVB 8.0 17 f.48 1
35 69 HOT 3RD AVB S.O 12 2.48 1
35 75 HOT IST AVB 8.0 10 2.15 1
35 78 HOT TIBESHEET 3.4 22 0.89 1
35 79 HOT tte TSP 7.1 7
1,42 1
35 84 HOT IST AVB 0.8 4
2.42 1
35 40 HOT tte AVB 0.0 4
3.96 1
35 85 HOT IST AVB 0.0 3
8 74 1
35 85 HOT 4TH AVB
% ("" T'I" 9 9 5
2.70 1
36 38 COLD TIBESHEET 1.2 3
8 78 1
36 59 COLD TUBESHEET 1.5 5
1,68 1
M 62 HOT 4TH AVB 0.0 7
1.54 1
36 62 COLD TUBESHEET 1.2 3
1.56 1
36 66 NOT IST AVB 0.0 6
2.74 1
36 73 HCT tte AVB 0.0 21 2.54 1
36 77 NOT TleESHEET 3.0 3
1.68 1
36 78 HOT tte AVB 0.8 12 2.90 1
36 79 HOT 298 AVB 8.8 4
1.57 1
36 St NOT IST AVB e.9 6
2.66 1
36 41 HOT 4TH AVB 0.0 8
3.79 1
37 21 HOT TUBESHEET 1.6 le 1.06 1
37 24 HOT 3RD TSP 13.2 3
2.87 1
37 27 HOT 3R0 AVB 0.0 28 1.71 1
37 30 HOT 3RD AVB 9.0 7
1.75 1
37 32 HOT tte AVB 0.0 14 2.56 1
37 38 COLD Tt2ESHEET 9.8 9
8 20 1
37 48 HOT tte TSP 2.3 38 0.56 1
37 49 COLD TLBESHEET 1.2 17 0.78 1
37 50 HOT tie TSP 4.7 37 1.52 1
37 52 HOT TuBESHEZT t.5 25 2.44 1
37 55 COLD TUBESM!tT 1.s 19
$.97 1
37 57 HOT Tt2ESHEET 3.8 31 0.95 1
37 57 COLD Time 5 HEFT 1.1 14 2.71 1
37 58 COLD TimESHEET 1.1 19 1.81 1
37 65 HOT IST AVB 0.0 9
2.17 l
1 37 66 HOT tre AV8 0.0 4
2.83 1
37 66 HGT 383 AVP 8.8 4
3.45 1
37 74 HO) 2tD TSP 11.2 23 1.67 1
38 32 HOT iTN AVB 4.0 9
1.28 1
38 48 HOT 41H AYB 0.0 7
1.24
l i
i
<~
3 8 8899.;..is9 9 49:
- 4. ;. 9 : H.*..* " - - 4 H. ; 9 9 :. 2 R. 4.".~. 4. 9. 9 :.s.9..;R.*4m:***
6.
5 8
=
l e.---
~
5
.~s s
=
m a exx:::
=~ euse:::ar = e-~ ~s--
e:- u= = z se = <===<:::ta--
s an.
O W
a 9
=
m e m :m m s e n--m.m ~--n--m--m s t e-- :----- 4 ~--.
"g3c-a :
.=~---~--er-==- =s------------a==-- ---------m---
i I
p
$.g
=
g 3
y
- f5 r
8 5 "8: E C
.!e!g ggrgkkkgthf9hkkkkkg<Ekkkf99BffffffRkkkkgtttk99999Fkkkff u
4 k
g g
-,<-.<-----, -~~<<<<<<<<<<<---, <<- <<<<<---<<
f0 j !!!!$!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
- - -EEERNEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE l
l g 33: 3*#2R0:32:4707:3 "3R2: 0RM22:2:3507.till233:3 # 2KRR AR A
/
l B
- R RR2AAA,AA..
............................. ~
m mn-----m----
i s
I
~~---------------------~~~---
y 5
t.
l m
y
s -
1 l
N N
---9 9-.
..-.9-N
--.---..-~~-.tt-~999
.----~
---9--~~-
E.
1 E
RI G
m E
h"*T3:*K"2"2"*=**M:".:nOS"*: 0
- "2**"*:"2
- "O*7"*""AR
.t a
l C
..tt..-..mm.......-9.-neN...................m.......--
l444f444444sfi4444444fiiff4444.:44444444444444f444444444 a
Es
?
.3-4 g.
p g
-ig r
nu E5 "g=II.a 1'
-s * !!BB!!BB!BBi!!!!!!BBiBBBB!.!!!E!!!!!!!!!!!!!!B!!BE!!!!B
.. s D3
" IEIIfIIIt-~!.fI~95559II.9 9IIfI59!afIE29 *E:5559592 2 29 9$2""R Eff t-NR9-44tN4~-~~~N
=t ttt-tN
~
b-3-
M fissiinssisilisississisississisissisississississisisisi i
I kd N
N i
8 l
l 1
.e N N N N N N N N N N N N N N N N N N N N N N N N N N N N M M M M M M M M t9494'ttt99999949444994944444449tt444444444449944499999 g_
5 N.
I
\\
l
4
'4 J
I i
b 4
s e -.. __._.____...<--_..._....<._._-_, _.._<--------..
s 2
x m
4 R
W O
N 4
5 E
- *2:
"*R:2*22"**
"*2**2 "2"~**2:**2"2"*20"**":2*M***"
a a
_5 l
M C
.._e.a...<m.....
....<.._..........-e..<......_....
~
l l Affidigisaidifi444444444fiig44444fgidiffgagdisdai44444 E
~
~k.'8 -
?
3 ju x
8 5
_II, ! aseenmaraneegneesesmeseemeegessengges.<enggameseneranee
~E t
O bb 2:
g -.. --- --..
E E.
05
" E,E E E E 9 9 5 I I k E R _ f E E E.5.f 2 9 _ 5 _2 9 5 E 2 E _2 9 E E E E E E " I E.E 9 9 5 5 5 9 9 9 9 _ 2 _3 k.
,,,R
=
_~ <
.. < ~~~ ~ _
B 3
l l
8issssssssssssssssssssssssssssssss!!ssisiisisisisssssss I02===0 :. :=========::=========Ta===:2:$===2-==
0m=
8 l
l 3.00000000000000000000000000000$$$$$$$$$$$$$$$$00000000 l
E
,i,_____________________________________________________
E
.a 1
l N
.S-f a fee - -
mf M
On eN-
. ~
e.
l e aa:a aaaaaaaa:ia a aaaaaa;;aaaa;a a :::iaaaaaaaaaa W
e D
4 Rw B
H E
~
- "C*N#EUIC'"E'*$$*U**dN
"$"*38
- NN"N"UN"8ED30*#"UNID e
m a
w 5
I U
~
ee-eeeeeeeeeeeeeeeeeeeeeeeeeeewemoemesepeucomoeone l
Ec, h E$dEE55EN$$$fa$$$$$$$$$$eM$$$$dE5*EME$$MMMMEEEEM5d E3e b
r
.t 3
9 g.:
Istb E-5 t
l
~B e5
$$hkhhEhhhk.hewhhhhhhhhhhEE k
5 5 $ $$$$
$ hhh S
.--<<<<<<<<<<<<<<<:-<<<<---<<<<<<<<hhh l
_gg 6
$ EfEREMEIEk2$5f.NE"EEEERNEEMMENDEGEMGEEEEE"E9EONEGEE l
- W'
-tmt<~,--~,--~~<~~u-~~~-,~A<~<--.---
ua
$ <<~~~~~
t--
B Ia e
h b
NN hh h khbkhhhhh khbbNb bhhkbbbkh b b h b N h h*
EEEEEEEEEEEEEE'EEEEEEEER=EEEEEEEEEEEEEEEEEEEEEEEEEE i
I g
l mng..mmemm. gm....~~mun-~~e.<a.m.
~--mm eam-nne.
g~m e
em <<<+...
mmar<<<<m.mm...
<mmmmm.
ar<<<tm m.
W
/
4 m
mmmmm 24 94g
$4444 4444944 N N k k h h h h e e e e e e e e e e' e m 49449999444tsw44wgt49449494w9999444499999994444494 8
Qe N
6
~~~~~~~~---~~~---------------~~~~--------------~~-
g e
5 e
v 1
1
1 SL99tAET OF A*L 7tst FLAteS Cats NEDr4E15AY Marot C 3906 3e FOR C1 19a6 EOST ClareENT F*tSPECTION Tot STEAM GEttEk". TOR et I
I STEA81 I
i 1
i S l
l 1.EMEitATCe
__..__.__I l
1 i
1 l
TOTAL 1
1 1.___
.......I l
l LOC l
LOC 1
I l-----------*-----------!
l l COLD l NOT l COLD 1 h0T I l
l_.__.,.....,__.....
....I l
IsaastalsmeralHipeEnlHunseni
)
l.0F l or 1 0F I 0F 1 1
IFLAHS lFLA645 IFLAWS 1 FLAWS 1 g--
,_____,.... 1 1stre I
I I
i I
t.
I s i
I i
1 l<tet i
0491 3661 8491 3661' l ____.. -
Ite-tm 1
Itti ist I_
. __. __....__,.__.__,_.....i atti tot.
tw-3'7x i
ssi 631 151 es l---..____
.tI l'e-49x I
31 asi 31 ast I...-
.I iso-sex l_.. I,l-
.......I si 11 si I.
16e-69x i
.I 11
.I 11 f......
....I 17e-79x I
.I 31 1.
..I 31
.I Iso-teox I
.I 11
.I 1
I.
.__........__......._,__............... 11 ITotAL I
9978 56sl 9978 56sl e
i i
G l
w y-
--+
s, e
w y
3 SLMtARY OF ALL TLSE FLANS e:13 NEONEsoAY, MAAOI 5, 1996 31 FM CY 19e6 E9eV CISWENT INePECTIst FOR STEAM eGERATM 01 ISTEAM l l
leENER-1 l
1 ATM i l
1
.1 I
I l 1 lioTAL ll 1
l _ _ __. -_. i l
lNUPSERINUMBERl i
I or i or 1 I
IFLANS IFLANS l l-
__l ISIzt i
I I
l ------
--I I
I l< rex I saisi taisi I
__.I les-29x I
asel asel l.
.._....I 13e-39x 7al 7el 1..
.__l 14e-49x l
rol tal i
I
+-
I Iso-59x I
61 el I
,_...._l 16e-69x l
11 11 1
.. __ I "l:,l 17e-79x
~i 31 31 l--
+----+-----I 19e-toex i
11 11 l...
I IToTAL 1 is6tl 1561 i
e i
i l
i I
l 1
StastART OF MAXIftM FLAN SIZES PER SIDE PER TLBE 4:15 NEDHESDAY. MARCH 5, 1986 32 FOR CY 1986 EDOT CtSWENT INSPECTION FOR STEAM GENERATOR et l
l STEAM i
l l
l GENERATOR l l
l 3.
..____l l
l l
1 1
TOTAL l
l l_.
.I l
l LOC l
LOC l
3 l_....-
..____...l l
l COLD l NOT l COLD I NOT I I
l.
._,______,..__ I I
INLRSERlHUPSERINUPSERINUPSERl i
1 Or i or i or i or I I
IFI me l FLANS l FLANS l FLANS l l._
.......__.1 ISIrf I
I I
I i
1-
_. _ l,
i l
l l<rer 1
7731 2731 7731 2731 g
las-29x i
1t91 a71 tesi a7 13e-39x i
151 sti 151 611 3
l 14e-49x i
si 241 31 241 l__.. _
.l 15e-59x
.l 41 11 41 i,
l-
- -,.,, I,l.
... l 16e-69x I
.__....____,_..__.,I 11
.1 18 3
.._l 170-79x I
1 31
.1 31 3.-
3 19e-teer l
.I 18
.1 11 1.
... ___,_........____l l
IT0rAL I
sail 4541 Sail 4541 I
i i
I I
t 6
i l
i, 9
i f
r
'3 SLROMRY OF MAXItemt FLAN CIZES PER Time C:15 NEDHE504Y. MaACM C, 19e6 H
FOR CY 1986 E90Y Ct2 RENT 3H5PECTION
- O FOR STEAM SENERATop C1 1
15Tran i I
I isENER-1 1
I 1 ATOR I I
I...__
I i
i i 1 IToTat i I
l------+------I I
INUMBERINUMBERI I
I of I oF I I
IFLaks l FLAWS I l__
,___.__.......l Isuzt i
I I
l___...__.
.l l
l l< rex I
9451 945 g___..__..__..
__..._____..__.........,____. 1g lae-tox I
titi tat I..__..
._____..........,___...!g 15e-39x l
761 761 l---------
*------+------l 14e-49x 1
278 271 l
,____..g 15e-59x i
si si l___...___....__
.I 16e-69x i
11 3.__.___....
..,_-__..ll 17e-79-4 I
il s
I-------------------------------+------+----- l I
19e-toex I
al 1
1...__
1 I
licial I tr7al tz7el e
k
SunnaRY OF TUBE IttSPECTIONS CY EXTENT C:15 WEDtE534Y. MARCN C.1966 34 FOR CY 1986 E00Y CURRENT 1HSPECTIDH
~
C FOR STEAM GEHE Z TOR C1
=
===__
8 I
STEAM i
l i
l i GENERATOR I l
I g...........!
I l
l I
l TOTAL i
i g..
........I I
I mesER OF I NUISER OF l I
IIPfSPECTI0tt5lINSPECTIDHS!
l-
- =--
-- - --+-
---+-
=== --I i
ILENGTH l
l I
a g.--=
_I l
l ITHIpo SUPPORT I
Il
+
l.............
___............l IFOURTH SUPPORT l
Il 1
I-----
=----------------+-----------+--- --
=l ITHsu u-eEND l
641 64l l-
---________...............................==_-
=..I lstCole SUPPORT - CL l
Il l---
- =---- - -+-
- - =+
=-----l IFULL LENGTH l
35991 35991 I...............
-I ITOTAL l
36661 36661 i
l i
4 h
d i
)
.t i
=+y.
e t
1