MONTHYEARML20204H2571984-11-0505 November 1984 Proposed Tech Spec Deleting Requirement for Auxiliary Feed Pump Turbine Inlet Steam Pressure Interlock Project stage: Other ML20204H2491984-11-0505 November 1984 Application for Amend to License NPF-3,revising Tech Specs to Delete Requirement for Auxiliary Feed Pump Turbine Inlet Steam Pressure Interlock Project stage: Request ML20204H2361984-11-0505 November 1984 Forwards Application for Amend to License NPF-3.Amend Changes Tech Specs to Delete Auxiliary Feed Pump Turbine Inlet Steam Pressure Interlock.Fee Paid Project stage: Request ML20138J0171985-10-25025 October 1985 Requests Withdrawal of Application for Amend to License NPF-3 to Delete Auxiliary Feedwater Pump Turbine Inlet Steam Pressure Interlocks Due to Decision to Retain Switch Interlocks within Main Steam Lines Project stage: Withdrawal ML20138K5201985-12-0202 December 1985 Notice of Withdrawal of 841105 Application for Amend to License NPF-3,deleting Low Pressure Switch Interlocks in Main Steam Lines to Auxiliary Feedwater Pump Inlets Project stage: Withdrawal ML20138K4981985-12-0202 December 1985 Grants 841105 Withdrawal of Application for Amend to License NPF-3,deleting Low Pressure Switch Interlocks in Main Steam Lines to Auxiliary Feedwater Pump Inlets.Fr Notice Encl Project stage: Withdrawal 1985-10-25
[Table View] |
Text
_ _ _ _
PLAtiT SYSTEMS SURVEILLANCE R50VIREMENTS (Continued) c.
The Auxiliary Feed Pump Turb'ine Steam Generator Level Control System shall be demonstrated OPERABLE by performance of a CHANNEL CHECK at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />, a CHANNEL FUNCTIONAL TEST at least once per 31 days, and a CHANNEL CALIBRATION at least once per 18 months.
d.
The Auxiliary Feed P, ump Suction Pressure Interlocksy
._..._.,7 snall be demonstrated OPERABLE by performance of a CHANNEL FUNCTIONAL TEST at least once per 31 days, and a CHANNEL CALIBRATION at least once per 18 months.
a 8411120234 841105 PDRADOCK05000g e
DAVIS-BESSE, UNIT 1 3/4 7-5 Amendment No. 4'3', 63 O $
.l