CHAPTER 1-J

,o g g.

EDISON u m, m or m,,,,,,

u tonou munno;ut coer.or ELECTRONIC DATA PROCESSING CONTROLS rAct I

or 6

- 0008R4.T -

trrtcityt Daft 12/20/96 RutstoM 4 1.0 Ltitroduction Quality assurance program controls consistent with the provisions of this Section (1-J) of tie manual shall be provided for the followings (a) electronic data processing systems and digital computer systems which are used for Quality Affecting Activities performed by SCE.

(b) Quality Affecting Software used by SCE.

2.0 Aeolicability 2.1 This Section (1-J) of the manual applies to Quality Affecting Software (used to implement Quality Affecting Activities) whose results are not independently verified on each use.

2.2 This Section (1-J) of the manual is not applicable to sof tware used in performing Quality Affecting Activities if results of the software are independently verified on each use by the procedures impl:menting the Quality Affecting Activity.

3.0 3,gsoonsibilities 3.1 System Soons2r, 3.1.1 A Systern Sponsor shall be designated in writing for QualityAffecting(SoftwarebytheCognizantFunctionalCFDM) or Olvision Manager for the primary Quality Affecting Activity.

l0 3.1.2 Responsibilities of supporting divisions shall be documented by the System Sponsor.

3.1.3 The System Sponsor shall be responsible for implementing the requirements of this Section (1-J) of the manual for Quality Affecting Software, except for those paragraphs specifically assigned in writing to System Implementing Organization.

\\

1 i

CHAPTER 1-J ELECTRONIC DATA PROCESSING CONTR0!$

REVISION 4 i

PAGE 2 0F 6 I

'l

+g l

3.2 }vstem tanlementina Dreanization i

l 3.'.1 The System $ponsor may designate a System Implementing Organtration. The designation shall be in writing, and shall specify which responsibilities of the System l

Sponsor are transferred to the Implementing Organization, f

j 4.0 SoftwarLJ)1falonne.nl

_4.1 Software Recuirements 4.1.1 The software requirements shall be established for Quality

-Affecting Software. The requirements shall be documented, reviewed, approved and shall consider, but are noi limited to, the following items:

(a)

Functionality /SystemDescription, including specific identification of Quality Affecting Activitiesand/ordataelements.

(b)

Interfaceswithorganizations, hardware,and/or other software, i

(c)

Human factors, i.e. ergonomics, color schemes.

(d)

Portability, accessibility,recoverabilityand/or maintainability criteria, t

[

(e)

Design constraints.

j (f)

Performance constraints.

(g)

Unique training requirements.

Responsibility: System Sponsor 4.2-Software Desian i.

4.2.1 The sof tware design shall implement the-software L

requirements. The design shall be documented, reviewed and approved. The software design shall consider, but is not limited to, the following items:

(a)

Data checking routines.

(b)

Data flow and control - a description of the flow l

of the data into, through and out of the software.

(c)

Control logic - a description of special logic or rules (algorithms) that may be applied when processing data.

.4 f*

. ~.

... - - ~

CHAPTER 1 J ELECTRONIC DATA PROCESSING CONTROLS REVISION 4 PAGE 3 0F 6 (d)

Organization of data.

(e)

Inputs and outputs.

(f)

Equations.

(g)

Coding conventions, where appropriate.

(h) lest plans and test cases.

(1)

Acceptance criteria Responsibility: System Sponsor 4.3 Software Construction 4.3.1 Methods and procedures shall be established to ensure that the software shall be constructed in accordance with the approved software design.

Responsibility: Cognizant Functional Division Manager 4.4 Software Verification and Validation 4.4.1 The software design shall be reviewed to provide verification of the adequacy of the design to meet the software requirements.

4.4.2 The validation process shall demonstrate that the software properly perforns the Quality Affecting Activity.

4.4.3 The verification and validation process shall be documented, reviewed and approved to ensure that software and any approved modifications implement the software requirements and the software design, and that other Quality Affecting Activities related to the software continue to function as designed.

Responsibility: System Sponsor 4.5 Procedure Impact Assessment 4.5.1 A procedure impact assessment shall be performed during the analysis or design phase, as appropriate, of the software development cycle.

4.5.2 The assessment shall identify any existing procedures that may require modification and/or the potential need for new procedures.

Responsibility: Cognizant Functional Division Manager

____________--____-_-_J

CHAPTER 1-J ELECTRONIC DATA PROCES$1NG CONTROLS REVISION 4 PAGE 4 0F 6 5.0 Software cod iouration Control 5.1 Confiauration Identification 5.1.1 A labelina methodology shall be developed to uniquely identify each configuration. The methodology shall provide the ability to uniquely identify each configuration of the software available for use and its documentation.

5.1.2 The configuration shall identify the approved software and shall be documented and controlled. This configuration shall include the elements listed below (a through d) and may include data files:

(a)

Documents (e.g. requirements, specifications, etc.).

(b)

Hardware and operate 4 system software versions.

(c)

Software development tool versions (e.g. code generators, compilers, language, CASE tools, etc.).

(d)

Other files (JCL, CLIST,. BAT files).

~

Responsibility: System Sponsor 5.2 confiouration Chanae control 5.2.1 A process shall be developed to ensure that changes are controlled and documented.

5.2.2 Changes to software are subject to design control measures as specified in paragraph 4.0.

Changes to design documents are reviewed and approved using current or equivalent controls which approved the original design document.

S.2.3 The configuration control process shall also ensure notification of System Sponsors, System Implementing Organizations and Users of the software that a configuration change has occurred.

Responsibility: Cognizant Fu.v.tional Division Manager 5.3 Data confiauration contrQ1 Methods and procedures shall be established to maintain the integrity of quality affecting data. See paragraph 4.1.1d for generic guidance.

Responsibility: Cognizant functional Division Manager

CHAPTER 1.J ELECTRONIC DATA PROCF.SSING CPITROLS REVISION 4 PAGE 5 0F 6 s

Y 5.4 When the configuration changes, a verification and/or validation process shall demonstrate that the sof tware continues to properly perform the Quality Affecting Activities specified in the software reqqirements documentation and the software design documentation.

Responsibility: System Sponsor 6.0 Use of Ouality Affectina Software 6.1 Methods and procedures shall be developed and used to create and maintain a list of Quality Affecting Software.

Responsibility: Cognizant Functional Division Manager 6.2 Methods and procedures shall be developed and used to ensure that the appropriate approved versions of software are used.

Responsibility: Cognizant functional Division Manager 7.0 Prob 1m Reportina and Corrective Action 7.'1 Methods and procedures shall be in accordance with the requirements of Section 1 F of this manual. These methods shall provide for the identification of errors in Quality Affecting Software, and for the implementation of actions to correct the

errors, g

Responsibility:

System Sponsor (Correction of Errors)

Cognizant functional Division Manager (DevelopmentofMethods& Procedures) 8.0 Data / System Recoverability 8.1 Methods and procedures shall be developed to ensure restoration of the system to a prior condition. An alternate means of perfoming the Quality Affecting Activity should be established.

Responsibility: Cognizant Functional Division Manager 9.0 Access Control 9.1 Controls shall be established to permit authorized and prevent unauthorized access to a computer system, source code or database.

Responsibility: Cognizant functional Division Manager

CHAPTER 1-J El.ECTC~NIC DATA PROCESSIM CONTROLS REVISION 4 PAGE 6 0F 6 10.0 Procurement 10.1 Software or software services procured to perform Quality Affecting Activities shall be purchased in accordance with the J

requirements of Section 3 A of this manual.

l0 10.2 All quality affecting software applications must have verification and/or validation perfomed and user documentation developed either by a qualified supplier or by SCE. When SCE perfoms the appitcation verificstion and/or validation testing and develops R

the user documer.tation, with no reliance on the supplier's pro or product certification, the software may be procured as non gram t;aality affecting (no procurement level).

'b 11.0 igftware Develoned Without the Use of Chanter 1-J l

Any quality affecting software purchased from a non-qualified su> plier which was not subjected to the controls stated in Section 10.0 stall be developed and designed in accordance t'th Section 4.1 and 4.2 and R

verified and validated in accordance with Section 4.4.

Responsibility System Sponsor lD 12.0 Quality Assurance Records

~

-12.1 The development, procurement, and modification of Quality Affecting Sof tware shall be documented according to the requiroents of Paragraph 4.0.

Responsibility: Cognizant Functional Division Manager 12.2 Quality Assurance records shall be maintained as required by Section 1-0 of this manual.

Responsibility: System Sponsor Corporate Documentation Services (CDS) Manager; Manager of Budgets and Administration 13.0 Trainina 13.1 Personnel using Quality Affecting Software controlled by Section (1-J) of this manual shall be trained on that software in accordance with Section 1-H of this manual.

Responsibility: Cognizant Functional Division Manager 14.0 Audits 14.1 Audits of activities described in this section shall be conducted in accordance with Section 1-E of this manual.

Responsibility: Manager of Nuclear Oversight

L ENCLOSURE 15 UFSAR SECTION REFERENCES

1 UFSAR Section that are relied upon in the J-SPA-289 Analysis The J SPA 289 analysis relies directly on the following accidents from Chapter 15 of San Onofre Nuclear Generating Station Units 2 & 3 Updated Final Safety Analysis Report, Revision 12.

)

i UFS AR Ref.15.1.2.3: Increase in Main Steam Flow with a Concurrent Single Failure of an Active Component Accident

2. UFSAR Ref. If.l.2.4: Inadvertent Opening of a Sternn Generator Atmospheric Dump Valve with a Concurrent Single Failure of Active Component Accident
3. UFSAR Ref.15.23.1: Feedwater System Pipe Break Accident
4. UFSAR Ref.15.4.3.2: Control Element Assembly (CEA) Ejection Accident
5. UFSAR Ref.15.6.3.1: Primary Sample or Instrument Line Break
6. UFSAR Ref.15.6.3 3: Loss-of-Coolant Accident (LOCA)
7. UFSAR Ref.15.7.3.4: Design Batis Fuel Handling Accident inside Fuel Building
8. UFSAR Ref.15.7.3.6: Spent Fuel Pool Gate Drop Accident
9. UFS AR Ref.15.7.3.8: Spent Fuel Pool Boiling Accident
10. UFSAR Ref.15.7.3.9: Design Basis Fuel Handling Accident inside Containment 4

l l

4

+

UFSAR Section that are relied upon in the J-SPA-289 Analysis The J SPA 289 analysis relics directly on the following accidents from Chapter 15 of San Onofre Nuclear Generating Station Units 2 & 3, Updated Final Safety Analysis Report, Revision 12.

)

1 UFS AR Ref.15.12.3: increase in Main Steam Flow with a Concurrent Single Failure of an l

Active Component Accident

2. UFSAR Ref.15.1.2.4: Inadvertent Opening of a Steam Generator Atmospheric Dump Valve with a Concurrent Single Failure of Active Component Accident
3. UFSAR Ref.15.2.3.1: Feedwater System Pipe Break Accident
4. UFSAR Ref.15.4.3.2: Control Element Assembly (CEA) Ejection Accident 5 UFSAR Ref.15.6.3.1: Primary Sample or instrument Line Break
6. UFSAR Ref.15.6.3.3: Loss of Coolant Accident (LOCA)
7. UFSAR ltef.15.7.3.4: Design Basis Fuel Handling Accident inside Fuel Building
8. UFSAR Ref.15.7.3.6: Spent Fuel Pool Gate Drop Accident
9. UFSAR Ref.15.7.3.8: Spent Fuel Pool Boiling Accident
10. UFSAR Ref.15.7.3.9: Design Basis Fuel Handling Accident Inside Containment

~