Georgia Power l'
POWER GENERAT6CN CEPtJTMENT
~
,i VOGTLE ELECTRIC GENERATif@G PLKNT '"g
'S TRAINING LESSON PLAN..
TITLE:
INTRODUCTION TO TECHNICAL SPECIFICATIONSNUMBER:
LO-LP-39201-00 PROGRAM:
LICENSED OPERATOR TRAINING REVISION:
0 AUTHOR:
R. SLOUGH DATE:
8/1/86 3
TgpjM DATE:
7/f//g APPROVED:
INSTRUCTORGUIDELINE[
OVERHEAD FOR TRANSPARENCIES WHITE BOARD WITH MARKERS l
90 -kOcck $$00j4 V
1 L
r LO-LP-39201-00 1.
PURPOSE STATEMENT:
TO FAMILIARIZE THE STUDENTS WITH WHERE THE REQUIREMENTS FOR HAVING TECHNICAL SPECIFICATIONS l COME FROM AND TO TEACH THE FORMAT THAT THE TECHNICAL SPECIFICATIONS ARE ARRANGED IN.
1 II.
LIST OF OBJECTIVES:
1.
The student will be able to explain where the requirements come from for Plant Vogtle to have technical specifications.
2.
The student will be able to explain the general layout of technical specifications including sections and subsections.
3.
The student will be able to give a one or two sentence description of the individual sections of technical specifications.
4.
The student will be able to explain what safety limits are designed to protect.
5.
The student will be able to list the three things the surveillanca requirements provide assurance for.
6.
The student will be able to list the five major categories covered in Administrative Controls.
I l
l 2
l
(..
' - "'-39201-00 REfFERENCES:
10CFR50.36 9
l f
i 3
L
P LO-LP-39201-00 c-111.
LESSON OUTLINE:
NOTES 1.
INTRODUCTION This lesson is designed to familiarize the students with where the requirements for having technical specifications come from and to teach the format that the technical specifications are arran,ged in.
II.
PRES ENTATION A.
Requirements for Technical Specifications 1.
Specified in 10CFR50.36 a.
Code of Federal Regulations b.
Chapter 10 is Energy c.
Part 50 1)
Domestic licensing of Production and Utilization facilities.
d.
Section 50.36 - Technical Specifications 2.
Requires each applicant to submit a draft.
a.
In accordance with the following section b.
Must include summary statement of bases or reasons for spec.
1)
Other than administrative 2)
Shall not become part of specifications 3.
Each license authorizing operation will include technical specifications.
a.
Will be derived from evaluation of FSAR.
b.
Commission may include those it finds appropriate.
B.
Will include the following categories:
LO-TP-39201-00-001 1.
Safety Limits, Limiting Safety System Settings a.
Safety Limits 1)
Limits on process variables 4
LO-LP-39201-00 lil.
LESSON OUTLINE:
NOTES 2)
Necessary to protect barriers against release of radioactivity 3)
If exceeded, required actions are:
a)
Reactor shall be shut down b)
Notify commission c)
Submit report d)
Not startup until permission from NRC b.
Limiting Safety System Settings 1)
Settings for automatic protective device 0 2)
If they protect against safety limits a)
Must be set before safety limit is reached 3)
If protective action doesn't occur a)
Take appropriata action b)
Notify commission.
c)
Submit report 2.
Limiting Condition for Operation a.
Lowest functional capability or performance j
level for equipment required for safe opera-tion.
b.
When LCO not met 1)
Shut down the reactor or 2)
Follow remedial action in Tech Specs until condition can be met 3)
Notify the commission 4)
Review the matter and record the results of the review 5
LO-LP-39201-00 lil.
LESSON OUTLINE:
NOTES 3.
Surveillance Requirements a.
Requirements related to test, calibration or inspection.
b.
Provides assurance that:
1)
Necessary quality of systems and components is maintained 2)
Facility operation will be within the safety limits.
3)
Limiting Conditions for Operation will be met.
4.
Design Features a.
Features of facility which:
1)
Would have a significant affect on safety if altered or modified, or 2)
Are not covered in. Safety Limits, LCO's, or Surveillances.
b.
Examples are:
1)
Materials of construction 2)
Geometric arrangements 5.
Administrative Controls a.
Provisions necessary to assure operation of facility in a safety manner.
1)
Organization and management 2)
Procedures 3)
Record keeping 4)
Review and audit 5)
Reporting 6)
Initial Notification a)
Reports to commission in response to requirements of this section.
6
LO-LP-39201-00 Ill.
LESSON OUTLINE:
NOTES C.
Format of Technical Specifications 1.
Addresses categories of 10CFR 2.
Consists of six sections LO-TP-39201-00-002 a.
Section 1*.0 - Definitions b.
Section 2.0 - Safety Limits and LSSS c.
Section 3.0 - Limiting Conditions for Operation d.
Section 4.0 - Surveillance Requirements e.
Section 5.0 - Design Features f.
Section 6.0 - Administrative Controls 3.
LCO's and surveillances presented in combined format (Section 3 and 4) a.
LCO appears at top of page b.
Followed immediately by. applicable surveillance requirement c.
Combined section 3/4 further subdivided into 12 subsections 1)
Reactivity Control - Section 3/4.1 LO-TP-39201-00-003 2)
Power Distribution - Section 3/4.2 3)
Instrumentation - Section 3/4.3 4)
Reactor Coolant System - Section 3/4.4 5)
Emergency Core Cooling System -
Section 3/4.5 6)
Containment Systems - Section 3/4.6
' 7)
Plant Systems - Section 3/4.7 8)
Electrical Systems - Section 3/4.8 9)
Refueling - Section 3/4.9
- 10) Special Test Exceptions - Section 3/4.10
- 11) Radioactive Effluents - Section 3/4.11
- 12) Radiological Environmental Monitoring -
Section 3/4.12 7
'a LO-LP-39201-00 lil.
LESSON OUTLINE:
NOTES III. SUHFMRY A.
Required by 10CFR50.36 B.
Has to include 6 sections LO-TP-39201-00-001 C.
Format of Technicar Specifications LO-TP-39201-00-002 1.
Safety Limits /LSSS a.
Protect barriers against release 2.
LCO's a.
Lowest functional performance level 3.
Surveillances provide assurance for:
a.
Quality maintained b.
Operation within safety limits c.
LCO's are mat.
4.
Design Features a.
Features of facility b.
Cannot be altered 5.
Admin. Controla - Provisions for:
a.
Organization and Management b.
Procedures c.
Record keeping d.
Review and audit l
e.
Reporting l
l D.
Section'3/4 further subdivided LO-TP-39201-00-003 l
l 8