_ _ _ _ _ _ _ _
Mr. J:mes H. Miller NOvsmb2r 26. 1997 Vice Pr:sident, Production U. S. Enrichment Corporation 2 Democracy Center
' 6903'Rockledge Drive Bethesda, MD 20817 i
SUBJECT:
PADUCAH AND PORTSMOUTH CERTIFICATE AMENDMENT REQUERTS,-
UPDATE OF THE APPLICATION SAFETY ANALYSIS REPORTS--
l ACKNOWLEDGMENT OF RECEIPT (TAC NOS L32043 and L32044) j l
Dear Mr. Miller:
We have received your applications to amend Certificates of Compliance GDP-1 and GDP-2 transmitted by letters dated August 18,1997, and October 31,1997, updating the application Safety Analysis Reports (SARs). Your requests have been assigned TAC No. L32043 for Paducah and TAC No. L32044 for Portsmouth. Please reference these numbers in any future correspondence associated with these reques,ts.
We have completed the initial administrative review of your application for amendments of your certificates. For those updated sections of the application SARs submitted for review, no omissions or deficiencies were identified, thereft,re, we have found them acceptable for formal re/aw. Please note that the formalieview may identify omissions in the submittalinformation or issues that require additional informat'on.
i Based on our administrative reviews and projection of current review schedules, we anticipate completing our review by July 30,1998. This date could change depending on the findings of our formal review, urgent assignments, or other factors. We will promptly communicate any significant charsgt s to this schedule.
A copy of your correspondence has been forwarded to our License Fee and Accounts Receivable Branch, Office of the Controller, who will contact you separately for billing if your request is subject to full cost recovery, if you have questions, please contact Charlie Cox at (301) 415-6755.
k Sincerely, f
Original Signed By h, - i 5
h=E [.nI@ in nOf>ggy Dan Martin, Section Leader O c w. ;
Enrichment Section
/
Special Projects Branch Ip'{}$
Division of Fuel Cycle Safety and Safeguards, NMSS Dockets 70-7001/70-7002 Certificates GoP-1/GoP-2 Dl11[M]ll1 LQN (Control No. 30QS.180SHTAC Nos. L32043,L32044)
I Docket'. 70-7001/70-7002 NRC File CenteM PUBUC KO'Brien. All!
CCo.,SPH NMSS r/f FCSSr/f WSchwink. FCOB M',orn, SPB SPBr/f KWinsberg, OGC PHitand. Rlil DMartin. SPB YFarar. SPB DHartland, Rill
- See previous concurrence OFC
- SPS
- SPB
- SPB C
- SPB E
SPB SPB NAME CCory YFerar
- MHorr, DHoodley DMartin RPierson DATE 11/26/97 11/26//97 11/26/97 11/26!97 11/26/97 11/ /97 C = COVER E = COVER & ENCLOSURE N = NO COPY OTsarup.ack OFFICIAL RECORD COPY 9712090049 971126 Il 11 l ; l11 jl lit il11 PDR ADOCK 07007001 lJ ll l j ll llll 4;
C PDR
- s ' s a ' *.
W.'$16sjes H. Miller ice 8tident, Producti:n UNITED STATES g
nr9:hment Corp @elliSLEAR REGULATORY COMMISSION n
U cy Center wasHINotow, o.c. soeswooi kledge Drive
- Bethe MD 20817
SUBJECT:
P QUCAH AND PORTSMOUTH CERTIFICATE AMENDMENT REQUESTS,-
UPD' TE OF THE APPLICATION SAFETY ANALYSIS REPORTS-ACKN EDGMENT OF RECEIPT (TAC NOS. L32043 and L32044)
Dear Mr. Miller:
We have received your appli tions to amend Certificates of Compliance GDP 1 and GDP-2 transmitted by letters dated August 18,1997, and October 31,1997, updating the application Safety Analysis Reports (SARs). Ypur requests have been assigned TAC No. L32043 for Paducah and TAC No, L32044 for rtsmouth. Please reference these numbers in any future correspondence associated with these quests.
We have completed the initial administrative eview of your application for amendments of your certificates. For those updated sections of the plication SARs submitted for review, no omissions or deficiencies were identified, therefo we have found them acceptable for formal review. Please note that the formal review may idenkfy omissions in the submittal information or issues that require additional information.
N Based on our administrative reviews and projection of cur eview schedules, we anticipate completing our review by July 30,1998. This date could chang depending on the findings of our formal review, urgent assignments, or other factors. We will p mptly communicate any significant changes to this schedule.
A copy of your correspondence has been forwarded to our License Fee d Accounts Receivable Branch, Office of the Controller, who will contact you separately or billing if your request is subject to full cost recovery.
If you have questions, please contact Charlie Cox at (301) 415-6755.
Sincerely, Dan Martin, Section Leader Enrichment Section Special Projects Branch Division of Fuel Cycle Safety and Jafeguards, NMSS N
Dockets 70-7001/70 7002 Certificates GDP-1/GDP-2 plSTRIBUTM (Control No. 300S.180SHTAC Nos. L32043,L32044)
Dockets 70 7001/70-7002 NRC File Center PUBLIC KO'Bnen, Rill CCom.SPB NMSS r/f FCSS t/f WSchwink. FCOB MHorn. SPB SPB t/f KWinsberg. OGC PHiland, hill DMirtin. SPB YFarar. SPB DHartiend, Rill 0FC SPB SPB SPB C
sPB SPB SPB N/.ME CCom:l}
YFare Horn DHoodley 0 Martin RPierson DATE
'97 12/ /97 11/ Ji/97 hM
/97 12/ /97 12/ /97 C = COVER E = COVER & ENCLOSURE N = NO COPY g:\\serup.ack OFFICIAL RECORu COPY
__.m_
93 C 8 @t,,
t UNITED STATES
'i
,j NUCLEAR RE2ULATORY CCMMISSION WASHINGTON, D.C. 2066H001
's,*..
+
November 26 1997 Mr. James H. Miller Vice President, Production U. S. Enrichment Corporation 2 Democracy Center 6903 Rockledge Drive Bethesda, MD 20817 i
SUBJECT:
PADUCAH AND PORTSMOUTH CERTIFICATE AMENDMENT REQUESTS,-
UPDATE OF THE APPLICATION SAFETY ANAL.YSIS REPORTS--
4 ACKNOWLEDGMENT OF RECEIPT (TAC NOS. L32043 and L32044)
Dear Mr. Miller:
We have received your applications to amend Certificates of Compliance GDP 1 and GDP 2 transmitted by letters dated August 18,1997, and October 31,1997, updating the application Safety Analysis Reports (SARs). Your requests have been assigned TAC No. L32043 for i
Paducah and TAC No. L32044 for Portsmouth. Please reference these numbers in any future correspondence associated with these requests.
We have completed the initial administrative review of your application for amendments of your certificates. For those updated sections of the application SARs submitted for review, no i
omissions or deficiencies were identified, therefore, we have found them acceptable for formal review. Please note that the formal review may identify omissions in the submittal information or issues that require additional information.
Based on our administrative reviews and projection of current review schedules, we anticipate completing our review by July 30,1998. This date could change depending on the findings of our formal review, urgent assignments, or other factors. We will promptly communicate any significant changes to this schedule.
j A copy of your correspondence has been forwarded to our License Fee and Accounts j
Receivable Branch, Office of the Controller, who will contact you separately for billing if your request is subject to full cost recovery.
If you have questions, please contact Charlie Cox at (301) 415-6755.
i Sincerely, lYf ft1 Dan Martin, ection Leader Enrichment Section Spccial Projects Branch Division of Fuel Cycle Safety and Safeguards, NMSS l
Dockets 70-7001/70-7002 Certificates GDP-1/GDP 2
-