AMENDMENT 1 TO RESAR-SP/90 PDA MODULE 7, " STRUCTURAL / EQUIPMENT DES 16N' INSTRUCTION SHEET t
1.
Insert pages 210-1 through 210-14 behind QUESTIONS / ANSWERS tab 2.
Remove existing Table 3.2-1, Sheets 1 through 42.
3.
Replace with Amendment 1, Table 3.2-1, Sheets 1 through 41.
4.
Remove existing Table 3.2-2, Sheet 1 (only).
5.
Replace with Amendment 1, Table 3.2-2, Sheet 1 (only).
i l
lO O
O O
!!APWR-S/E i
AMENDMENT 1 MAY, 1986
210.1
GENERAL COMMENT
Section 3.2.2 references ANSI /ANS-51.1-1983 which has established a classification system of nuclear safety classes for structures, systems and components of a nuclear power plant.
This classification system consists of four classes:
Safety Class 1 (SC-1), Safety Class 2 (SC-2), Safety Class 3 (SC-3), and Non-Nuclear Safety (NNS).
The principal industry construction codes and standards for j
pressure-retaining components applicable to SC-1. SC-2, SC-3, and NNS correspond to those identified in 10CFR50.55a for Quality Group A and Table 1 of Regulatory Guide 1.26 (R.G.1.26) for Quality Groups B, C and D.
However, the detailed guidance provided in ASNI/ANS-51.1-1983 for fluid system components is not consistent with the guidance in R.G.1.26 and the individual Standard Review Plans in NUREG-0800-1981 for those fluid systems not identified in R.G.1.26.
ANSI /ANS-51.1-1983 has not been endorsed by the NRC and is, therefore, not used by the staff in determining the acceptability of the classification of structures, systems and components.
The following inquiries are the results of an NRC staff review based on current NRC Regulations, R.G.1.26, R.G.1.29 R.G.1.84, R.G.1.85, R.G.1.143 and R.G.1.151, the appropriate SRPs in NUREG-0800, and current NRC staff practice.
RESPONSE
As a designer of the nuclear power block, Westinghouse has the responsibility, even at the design stage, of establishing conformance l
with the criteria.
In addition to considering ANSI /ANS-51.1-1983, NRC regulations, and other published guidance, Westinghouse must ensure that the design bases and expected operational characteristics are supported, to the extent practical, by design
- analyses, experimental verifications, and comparisons to accepted designs or experience gained f rom similar designs.
Consideration of alternate or additional criteria and requirements may be necessary to accommodate unique site characteristics.
'O WAPWR-S/E 210-1 AMENDMENT 1 i
4858e:1d MAY,1986
ANSI /ANS-51.1-1983 is a complete revision and combination of earlier standards and represents the latest consensus of the nuclear industry on these matters.
It has been prepared to incorporate additional requirements for the design of pressurized water reactor (PWR) nuclear power plants and to address three major areas:
1.
Safety Classes are defined and requirements specified for all equipment and structures according to importance to nuclear safety and capability for maintenance, surveillance testing, and inspection, or into a Non-Nuclear Safety Class.
2.
The concept of Plant Conditions is developed that includes individual process conditions, combinations of process conditions, and the combinations of process conditions and external hazards that could result in simultaneous effects on plant equipment.
3.
Desian Reauirements are provided for all Safety Classes and Non-Nuclear Safety Class in terms of industry codes and standards for each category of Plant Conditions.
In addition, ANSI /ANS-51.1-1983 is responsive to the regulatory requirements of the Nuclear Pegulatory Commission (NRC) including, in part, the code of Feder&1 Regulations Title 10, Part 50, Appendix A, " General Design Criteria for Nuclear Power Plants.'
i incorporating the requirements of ANSI /ANS-51.1-1983 provides a degree of assurance that, in their entirety, plants are designed and constructed so that they can be operated without undue risk to the l
health and safety of the public.
Our responses to this request for additional information are based on the continued use of ANSI /ANS-51.1-1983 in the APWR Nuclear Power Block.
O
!!APWR-S/E 210-2 AMENDMENT 1 4858e:ld MAY, 1986 i
210.2 In Table 3.2-1, Sheet 2, "Other safety-related supports and hangers" l
of the Reactor Coolant System (RCS) are incorrectly classified Quality Group C and Safety Class 3.
To be acceptable, safety-related supports and hangers of the RCS should be classified to the same Quality Group and Safety Class as the component that is being supported.
RESPONSE
Line Item 15. "Other Safety-Related Supports and Hangers" in the RCS has been revised to note that these items, are to correspond to the function provided by the supported equipment unless failure of the support could not jeopardize the function of the equipment.
210.3 In Table 3.2-1 Sheet 2,
Vessel internals, fuel assemblies, integrated head
- package, CRDM-mechanism, and control rods are incorrectly classified Quality Group C and Safety Class 3.
To be acceptable, these safety-related components should be classified Quality Group B and Safety Class 2.
RESPONSE
Classification of these components has been revised to correspond to ANSI /ANS-51.1-1983, Section 3.3.1.3.g.
The designations of Quality Group C and Safety Class 3 are considered appropriate for these items.
210.4 In Table 3.2-1, Sheet 2, identify those portions of the CRDM-housing that are classified Safety Class 2.
RESPONSE
The CRDM and DRDM housing line items on sheet 2 have been revised to indicate only Safety class 1 for these components.
O o
WAPWR-S/E 210-3 AMENDMENT 1 4858e:1d MAY, 1986 1
210.5 In Table 3.2-1, Sheet 3, the boron injection surge tank is classified Quality Group C and Safety Class 3.
Provide a P&I diagram showing the location of this component in the safety injection system and discuss the basis for the classification.
RESPONSE
The present design of the Integrated Safeguards System (ISS) does not i
include a boron injection surge tank.
Sheets 3, 4, 5, and 6 of Table 3.2-1 are revised for consistency with the current design of the ISS.
O 210.6 In Table 3.2-1 Sheet 7, Item 8, should be identified as " Positive Displacement Pump."
RESPONSE
Item 8 on Sheet 7 has been revised to read " Backup Seal Injection Pump" to agree with the current design of the Chemical and Volume Control System, which is described in SP/90 PDA Module 13. " Auxiliary l
Systems."
!O j
21 0.7 In Table 3.2-1, Sheet 7, the shell of the letdown heat exchanger and i
the excess letdown heat exchanger are incorrectly classified Quality Group D, Safety Class NNS, Code Classification C, and Q-List N.
To i
be acceptable these components which perform a safety function should be classified Quality Group C. Safety Class 3, Code Classification 3 and Q-List Y.
RESPONSE
The shell side portion of the letdown HX and excess letdown HX do not perform a safety function.
However, to assure the integrity of the HX's, the entire units are constructed to ASME Section III requirements.
The designations of Quality Group D Safety Class NNS, and Q-list N are considered appropriate for the shell side service of these units.
l O
WAPWR-S/E 210-4 AMENDMENT 1 i
T858e:1d MAY,1986 l
l
210.8 Does the design of the Chemical and Volume Control System include a seal water heat exchanger that cools primary coolant from the reactor coolant pump seals? If so, include this component in Table 3.2-1.
RESPONSE
The seal injection heat exchanger has' been included in Table 3.2-1.
In addition, the listings for the CVCS have been revised to agree with the current design of this system.
210.9 Does the design of the Chemical and Volume Control System include components, such as reactor coolant filters, seal water return filter, and seal water injection filters?
If so, include these components in Table 3.2-1.
RESPONSE
These components are now included in Table 3.2-1 for the CVCS.
See the revised listings for the CVCS.
210.10 In Table 3.2-1, Page 1, include power operated block valves as a line item.
RESPONSE
Power operated block valves have been included in Table 3.2-1.
See the revised listings for the RCS.
210.11 In Table 3.2-1 Page 20, the day tanks are incorrectly classified Quality Group NA.
To be acceptable these safety-related components should be classified Quality Group C.
RESPONSE
The diesel generator day tank classification has been revised to Quality Group C.
O WAPWR-S/E 210-5 AMENDMENT 1 4858e:1d MAY, 1986
- I 210.12 In Table 3.2-1 Page 25, the cooling fans, ductwork, and dampers of the Containment Air Cooling System are classified Safety Class 3.
If these components perform a safety-related function to be acceptable they should be classified Safety Class 2.
Provide a discussion justifying your Safety Class 3 classification of the components of the Containment Air Cooling System.
RESPONSE
All components within the Containment Air Cooling System have been reclassified to Quality Group B.
The safety classifications of the coolers and other system components to support operation of this function remain as Safety Class 2 and 3, respectively, in accordance with ANSI /ANS-51.1-1983.
monitors, and 210.13 In Table 3.2-1, Sheet 27 other piping and valves, H2 H
recombiners of the H recombiner and monitoring system are 2
2 incorrectly classified Quality Group C or NA, Safety Class 3, and Code Classification 3 or C.
To be acceptable, these safety-related components should be classified Quality Group B, Safety Class 2, and Code Classification 2.
RESPONSE
I All components within the hydrogen recombiner and monitoring system have been reclassified to Quality Group B.
The safety l
classifications of the system components to support operation of this function remain as Safety Class 2
or 3 in accordance with ANSI /ANS-51.1-1983.
O 210.14 In Table 3.2-1 Sheet 38, the fuel transfer tube housing and bellows assembly is incorrectly classified Quality Group C and Safety Class 1
3.
To be acceptable, this component should be classified Quality Group B and Safety Class 2 because it is an extension of the containment boundary.
l O
WAPWR-S/E 210-6 AMENDMENT 1 l
4858e:1d MAY,1986
RESPONSE
The classifications of the fuel transfer tube housing and bellows assembly have been revised to Quality Group B and Safety Class 2 consistent with ANSI /ANS-51.1-1983.
210.15 In Table 3.2-1, Sheet 39, the fuel transfer tube is incorrectly classified Quality Group C and Safety Class 3.
To be acceptable, this component should be classified Quality Group B and Safety Class 2.
. O
RESPONSE
The classifications of the fuel transfer tube have been revised to Quality Group B and Safety Class 2 consistent with ANSI /ANS-51.1-1983.
210.16 In Table 3.2-1, Sheet 39, the fuel handling machine, spent fuel handling tool, fuel transfer conveyor system and controls, integrated head lifting rig (portions that furnish support for CRDM's) and new and spent fuel storage racks are incorrectly classified Quality Group NA and Safety Class NNS.
To be acceptable, these components should be classified Quality Group C and Safety Class 3.
RESPONSE
The classifications of these components have been revised to Quality Group D as they may contain radioactive material.
The safety i
classifications remain as NNS consistent with ANSI /ANS-51.1-1983.
210.17 Verify that all components within the reactor coolant pressure boundary as defined in 10CFR Part 50.2 (v) are classified Quality Group A and constructed to Section III, Class 1, of the ASME Boiler and Pressure Vessel Code in compliance with the Codes and Standards Rule, Section 50.55a of 10CFR Part 50, or as a minimum, are classified Quality Group B and constructed to Section III, Class 2, of the ASME Code if the components meet the exclusion requirements of the rule.
O MAPWR-S/E 210-7 AMENDMENT 1 i
l 4858e:1d MAY, 1986 l
i
e B
Provide a comitment that components constructed to Class 1 of the Code shall be in full conformance with all the articles in Subsection NB of Section III including the Code N-stamp.
RESPONSE
Components that form a part of the APWR RCS pressure boundary as defined in 10CFR50.2(v) are classified as Quality Group A and constructed to ASME Core Section III, Class 1 in compliance with the Codes and Standards Rule 10CFR50.55a.
As a minimum, the RCS pressure boundary components that may be classified as Quality Group B and constructed to ASME Code Section III Class 2 will meet the exclusion requirements of 10CFR50.55a(c)(2).
We fully anticipate that components constructed to Class 1 of the ASME Code will be in conformance with Section NB of Section III of the code.
I 210.18 Verify that component supports are the same Quality Group Classification as the component being supported and are constructed to the same ASME Code Class in ac'cordance with Subsection NF of Section III of the Code.
Provide a note to this effect in Table l
3.2-1.
f
RESPONSE
A note has been added to Table 3.2-1 that safety related supports and hangers are to be classified corresponding to the function provided l
by the supported equipment unless failure of the support would not jeopardize the function of the equipment.
As appropriate, Subsection NF of Section III of the code is to be utilized.
210.19 Regulatory Guide 1.151 conditionally endorses the Instrument Society l
of America Standard ISA-567.02, " Nuclear Safety-Related Instrument Sensing Line Piping and Tubing Standards for Use in Nuclear Power Plants," 1980 as a basis acceptable to the NRC staff for the design and installation of safety-related instrument sensing lines in nuclear power plants.
Provide a comitment that safety-related instrument design lines for the WAPWR will be in conformance with Regulatory Guide 1.151.
WAPWR-S/E 210-8 AMENDMENT 1 4858e:1d MAY, 1986
RESPONSE
Regulatory Guide 1.151 generally endorses ISA-567.02 and was 4
developed to provide guidance for the design and installation of instrument sensing lines.
In endorsing this standard, the NRC has presented several additional regulatory positions addressing common l
sensing lines, mechanical design, and environmental considerations.
l Industry standard ISA-567.02 reiterates and clarifies the Westinghouse practice as expressed in the controlling documents, i.e.,
interface requirements and regulations.
Westinghouse utilizes the Engineering Flow Diagram as the approved document to designate the safety classification system boundaries for use by the BOP / Architect-Engineer.
Instrument lines that are attached to the safety class process piping in NPB systems show a continuation of safety class f rom the process piping to the instrument lines and instruments.
Where there is a transition between the safety class, this information is also reflected accordingly.
The following represents the Westinghouse position relative to the additional regulatory positions listed in Part C of the guide:
Positions 1.
4.
and 5:
Westinghouse agrees and follows these regulatory positions.
Position 2(a):
Westinghouse agrees with this position and includes the appropriate information on the related engineering diagrams.
Position 2(b):
Westinghouse does not completely agree with this subpart.
There does not appear to be a technical basis for the designation of sensing lines as ASME Class 2 from the restriction device out to the sensing instrumentation.
Upgrading of this portion of the sensing lines to an ASME Class 2 status gives no consideration to design features such as flow restrictors or diaphragms as class separation.
This upgrading of status will be of no added benefit, will not necessarily enhance safety, nor will it make system f ailure l
any less likely.
Rather, consideration should be given to evaluation on a case-by-case benefit-risk assessment basis.
For that portion of O
WAPWR-S/E 210-9 AMENDMENT 1 l
4858e:ld MAY, 1986
the sensing line from the ASME Class I piping or vessel out to the restriction device, ISA-567.02 now includes the ASME Class 1
requirement; Westinghouse agrees with this classification.
For that portion of the sensing line penetrating the containment barrier, ISA-567.02 now designates an ASME Class 2 requirement; Westinghouse agrees with this classification.
Position 3:
Westinghouse does not agree with this regulatory position.
There does not appear to be a technical basis for the designation of sensing lines as seismic Category I when connected to piping or vessels that are non-nuclear safety and are not designated as seismic Category I.
Upgradir.g of these sensing lines to seismic Category I will be of no added benefit, will not necessarily enhance safety, nor make system failures any less likely.
Rather, they should be evaluated on a case-by-case benefit-risk assessment basis.
Position 6:
Agreement or disagreement with this regulatory position is moot.
Applicable codes and code addenda are clearly established by other documents.
210.20 A number of ASME Code Cases are identified in Regulatory Guides 1.84, 1.85, and 1.147 as conditionally acceptable.
That is, Regulatory Position C.1 of each guide identifies additional conditions that should be imposed in addition to those conditions specified in each Code Case.
Provide a comitment that when conditionally approved Code Cases are used in the construction of ASME Section III, Class 1, 2, 3, MC, NF, and NG components that you will be in compliance with the additional conditions applicable to each of the conditionally approved Code i
Cases that are identified in Regulatory Guides 1.84,1.05, and 1.147.
O l
O WAPWR-S/E 210-10 AMENDMENT 1 4858e:1d MAY,1986
RESPONSE
10CFR50.55a
- requires, in
- part, that structures,
- systems, and I
components are to be designed, f abricated, tested, and inspected to quality standards commensurate with the importance of the safety function to be performed.
In addition, these structures, systems, O
and components are to meet requirements of the ASME Code as well as applicable addenda and optional Code Cases.
The WAPWR will be in compliance with this intent of 50.55a.
l For Code Case acceptability for Design and Fabrication (R.G.l.84),
Materials (R.G.l.85), and Inservice Inspection (R.G.l.147),
1.
Westinghouse controls its suppliers to:
a.
Limit the use of code cases to those listed in Regulatory Position C.1 of the Regulatory Guide revision in effect at the time the equipment is ordered, except as allowed in item 2 below.
O b.
Identify and request permission for use of any code cases not listed in Regulatory Position C.1 of the Regulatory Guide revision in effect at the time the equipment is ordered, where use of such code cases is needed by the supplier.
c.
Permit continued use of a code case considered acceptable at the time of equipment order, where such code case was q
subsequently annulled or amended.
D 2.
Westinghouse seeks NRC permission for the use of code cases needed by suppliers and not yet endorsed in Regulatory O
Position C.1 of the Regulatory Guide revision in effect at the time the equipment is ordered and permits supplier use O
WAPWR-S/E 210-11 AMENDMENT 1 4858e:ld MAY,1986
only if NRC permission is obtained or is otherwise assured (e.g., a lO later version of the regulatory guide includes endorsement).
210.21 The Codes and Standards Rule, Section 50.55a of 10CFR Part 50, requires in Part (g) that pumps and valves which are classified as ASME Section III, Code Classes 1,
2 or 3 and whose function is important to safety be designed and provided with access to enable the performance of inservice testing of the pumps and valves for assessing operational readiness set forth in Section XI of the Code.
It is the NRC staff position that design of fluid systems that perform a safety function shall permit pumps and valves to be tested in accordance with Section XI; for example, test return lines for pumps, and leak rate testing lines for valves.
Valves, such as check i
valves, shall be of a type that permits exercising the disc to the open or closed position as required to perform the safety function.
Requests for relief from the Code will not be granted for pumps and valves of the WAPWR that do not meet these requirements.
Provide a commitment that pumps and valves in fluid systems that perform a safety function will be in compliance with part (g) of Section 50.55a and Section XI of the Code.
RESPONSE
(
10CFR50.55a requires, in part, that systems and components are to be designed, fabricated, tested, and inspected to quality standards conenensurate with the importance of the safety function to be performed.
In addition, these systems, and components are to meet requirements of the ASME Code as well as Applicable Addenda and optional Code Cases.
The WAPWR will be in compliance with this intent of 50.55a.
O WAPWR-S/E 210-12 AMENDMENT 1 4858e:ld MAY, 1986
210.22 Verify that component supports for multiclass components, such as heat exchangers, are the same Quality Group classification as the higher classification assigned to the component and are constructed to the more restrictive ASME Code Class in accordance with Paragraph NCA-2133 (b) of the Winter 1983 Addenda to Section III of the ASME Code.
RESPONSE
Supports for multiclass safety related components are classified to the higher classification corresponding to the supported equipment.
This higher classification applies unless failure of the support would not jeopardize function of the equipment.
As appropriate,Section III of the Code with applicable Addenda and optional Code Cases are utilized.
210.23 The Codes and Standards Rule, Section 50.55a of 10CFR Part 50, requires that Quality Group B components meet the requirements of ASME Section III, Class 2, and Quality Group C components meet the requirements of ASME Section III, Class 3.
Provide a consnitment that components constructed to Class 2 and Class 3 of the Code shall be in full confonnance with all the articles in Subsection NC and ND of Section III including the code N-stamp.
RESPONSE
l 10CFR 50.55a requires, in part, that Quality Group B and C components are to be designed, fabricated, tested, and inspected to quality l
standards commensurate with the importance of the safety function to be performed.
In addition, these Quality Group B and C components are to meet applicable requirements of the ASME Code as well as Addenda and optional Code Cases.
The WAPWR will be in compliance with this intent of 50.55a.
1.
For Code Case acceptability Westinghouse controls its l
suppliers to:
lO WAPWR-5/E 210-13 AMEN 0 MENT 1 i858e:ld MAY, 1986
~ ^ '
' ~ ~ '
n e
a.
Limit the use of code cases to those in effect at the time the equipment is ordered, except as allowed in item 2, below.
b.
Identify and request permission for use of any code cases not in effect at the time the equipment is ordered, where use of such code cases is needed by the supplier.
c.
Permit continued use of a code case considered acceptable at the time of equipment order, where such code case was subsequently annulled or amended.
2.
Westinghouse seeks NRC permission for the use of code cases needed by suppliers and not yet endorsed at the time the equipment is ordered and permits supplier use only if NRC permission is obtained or is otherwise assured.
210.24 Provide a set of piping and instrumentation diagrams showing in detail the Quality Group (Safety Class) classification boundaries for systems that perform a safety function and are within the scope of the WAPWR,
RESPONSE
Piping and instrumentation diagrams for systems in the NPB are available in RESAR SP/90 PDA Module 1,
" Primary Side Safeguards System."
The P&ID's include safety classification boundaries.
'A Westinghouse " Flow Diagram Legend has been provided for your use in reviewing the P&ID's.
l l
O
- O WAPWR-S/E 210-14 AMENDMENT 1 4858e:1d MAY,1986
O O
O TABLE 3.2-1 (Sheet 1 of 41)
CLASSIFICATION OF STRUCTURES. COMPONENTS. AND SYSTEMS (a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(1)
Principal Principal System Quality Safety Seismic Code Construction Safety and Components Location Group Class Category Classification Code & Stds.
0-list Related Comments REACTOR COOLANT SYSTEN
- 1. Reactor vessel B
A 1
1 1
III Y
Y l
and head
- 2. Steam generator B
A 1,2 I
1,2 111 Y
Y g
- 3. Pressurizer B
A 1
1 1
til Y
Y i
l
- 4. Pressurizer B
A 1
1 1
111 Y
Y t
surge line
- 5. Pressurizer B
A 1
I 1
111 Y
Y rellef lines (upstream of
{
relief valves) l
- 6. Safety and B
A 1
I 1
III Y
Y relief valves
- 7. Pressurizer B
D NNS I
3 Ill N
N Note 1 relief tank
- 8. Reactor coolant B
A 1
1 1
III Y
Y pump casing
- 9. RCS loop piping B
A 1
I 1
III Y
Y
- 10. Valves B
A 1
1 1
III Y
Y
- 11. Reactor vessel B
A 1
1 C
III-NF Y
Y supports
- 12. Steam generator B
A 1
1 C
III-NF Y
Y supports
- 13. Pressurizer B
A 1
1 C
III-NF Y
Y supports
- 14. Reactor coolant B
A 1
I C
til-NF Y
Y pump supports i
WAPWR-S/E AMENDMENT 1
)
485tia:1d NAY, 1986
O TABLE 3.2-1 (Sheet 2 of 41)
CLASSIFICATION OF STRUCTURES. CORPONENTS. AND SYSTEMS I
(a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(1)
Principal Principal System Quality Safety Seismic Code Construction Safety i
and Components location Group Class Cateoory Classification Code & Stds.
0-List Related Cosaents i
l1
- 15. Other safety-B C
3 I
C lil-NF Y
Y.
See Note S related supports and hangers
- 16. Lube oil drain B
D NNS II 4
API-650 N
N tanks 1
- 11. Pseer Operated B
A 1
I 1
III Y
Y i
Block Valves 1
- 18. Power Operated B
NA 3
I E
NEMA MG1 Y
Y l
Block Valve Operators i
REACTOR SYSTEM
- 1. Vessel internals B
B 3
I NG 111 Y
Y y
- 2. Fuel assemblies B
B 3
1 3
M Y
Y
- 3. Integrated head B
C/D 3
I NF 111 Y
Y j
Package i
- 4. CRDM-housing B
A 1
1 1
III Y
Y j
- 5. CRDM-mechanism B
B 2
1 2
M Y
Y l
- 6. Control rods B
B 2
1 2
M Y
Y REACTOR HEAD VENT SYSTEM l1
- 1. Piping and valves B
A 1
1 1
Y Y
See Note S through second 1
isolation l1
- 2. All other piping B
B 2
I 2
111 Y
Y See Note S and valves
- 3. Instrumentation 8
NA 3
I J
mfg Y
Y l
WAPWR-S/E AMENDMENT 1 dR 5Rp = 1 st MAy, 1986
TA8LE 3.2-1 (Sheet 3 of 41)
CLAS$1FICATION OF STRUCTURES. COMPONENTS AND SYSTERS (a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(1)
Principal Principal System Quality Safety Seismic Code Construction Safety and Components Location Group Class Cateeory Classification Code & Stds.
0-List Related Coseents I::TEGRATED SAFEGUARDS SYSTEM
- 1. Accumulators B
B 2
1 2
III Y
Y
- 2. Core Reflood Tanks 8
8 2
I 2
III Y
Y j
j
- 3. Emergency Wate.-
8 8
2 I
2 III Y
Y j
Storage Tank j
- 4. Low Head Pumps C
B 2
I 2
III Y
Y
- 5. Low He-d %ap Motcrs C
N/A 3
I E
NEMA MG1 Y
Y j
- 6. High Head Safety C
8 2
I 2
III Y
Y Injection Ptaps
- 7. High Head Safety C
NA 3
I E
NIMA M61 Y
Y Injection Pump Motors i
- 8. Injection piping 8
A 1
1 1
III Y
Y See Note S and valves down-stream of check valves 1
- g. Accumulator dis-B A
1 I
1 III Y
Y See Note S charge piping and a
valves down-stream of MOVs j
- 10. Piping and BC B
2 I
2 III Y
Y See Note S valves f rom j
EWST and con-i tainment sumps to check valves l
- 11. Piping from B
B 2
I 2
III Y
Y See Note S accumulators
]
to MOVs WAPWR-S/E 4853e:1d AMENOMENT 1 MAY, 1986
l TABLE 3.2-1 (Sheet 4 at 41)
CLASSIFICATION OF STRUCTURES. Components. AND SYSTEsts (a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(1)
Principal j
Principal System Ouality safety Seismic Code Construction Safety 1
and Components Location Groop_
Lless Cateeory Classification Code & Stds.
0-list Related Comments l
1 j
- 12. Low Head Pump mintflow MX's Tube Side C
8 2
I 2
III Y
Y Shell Side C
C 3
I 3
TEM-R Y
Y
- 13. Safety-related 8,C NA 3
I J
mfg Y
Y j
instrumentation 1
- 14. Safety-related 8,C NA 3
I E
NE M NG1 Y
Y
)
valve operators
- 15. RHR MXs:
Tube side, 8
8 2
1 2
III Y
Y RHR TEMA-R 1
Shell side, B
C 3
I 3
III Y
Y CCW TEMA-R l
- 16. Piping and 8,C 8
2 1
2
'lII Y
Y See Note 5 1
valves from i
)
hot legs MOV's to pump suction
- 17. Piping and C
8 2
1 2
III Y
Y See Note 5 l
1 valves from j
pump suction I
injection check 1
valves j
j
- 18. Containment Spray 8
8 2
I 2
III Y
Y See Note 5 header nozzles i
)
CHEMICAL ANO VOLUME CONTROL SYSTEM I
- 1. Volume control C
8 3
1 3
Ill N
N 1
tank i
1
[fAPWR-5/E AMENOMENT I I
j 4858e:1d MAY, 1986 i
l l
l
s TABLE 3.2-1 (Sheet 5 of 41)
CLASSIFICATION OF STRUCTURES. COMPONENTS. AND SYSTEMS (a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(1)
Principal Principal System Quality Safety Seismic Code Construction Safety
.and Components Location Group Class Cateeory Classification Code & Stds.
0-list Related comments
- 2. Soric acid C
C MS II C
III N
N storage tank
- 3. Boric acid C
D MS II C
API-650 N
N batching tank
- 4. Boric acid C
C NNS II C
III N
N transfer pugs
- 5. Boric acid C
NA MS II E
NEMA NG1 N
N transfer pump motors
- 6. Centrifugal C
B 3
I 3
III N
N charging pumps
- 1. Centrifugal C
NA NNS II E
NEMA NG1 N
N charging pug motors
- 8. Backup seal C
8 3
I 3
III N
N y
injection pumps
- 9. Backup seal C
NA MS II E
NEMA ngl N
N injection pump motors
- 10. Regenerative B
B 3
I 3
III N
N HX TEMA-R
- 11. Letdown NX:
Tube side, B
8 3
I 3
III N
N CVCS TEMA-R Shell side, B
D NNS I
C III N
N Note n ACCW TEMA-R
- 12. Excess letdown HX:
Tube side.
8 8
3 I
3 III N
N CVCS TEMA-R Shell side.
B D
NNS I
C III N
N Note n ACCW TEMA-R WAPWR-5/E AMENOFENT 1 4858e:1d MAY, 1986
O C
O' O
O TA8tE 3.2-1 (Sheet 6 of 41)
CLAS$1FICAT10N OF STRUCTURES. COMPONENTS. AND SYSTEMS (a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(1)
Principal Principal System Quality Sofety Seismic Code Construction Safety and Components location Group Class Category Classification Code & St%. ' Q-M,s1 Related Cgue;1ti
- 13. CVCS cation C
C 3
1 3
Ill N
N.
bed domin-eralizers
- 14. Nixed bed
'C C
3 1
3 Ill N
N 1
demineralizers i
- 15. Boric acid C
NA NNS II E
UL M
N tank heater
- 16. Chemical mixing C
D NNS 11 C
Vill N
N tank e
- 17. Safety-related C
NA 3
I J
mfg Y
Y CVCS instru-i mentation
- 18. Piping to C
G NNS 11 C
831.1 N
N See Note S boric acid storage tank
- 19. Piping and C
D NNS 11 C
B31.1 N
N See Note S valves froe boric acid storage tant 1
- 20. Chemical mixing C
0 NNS 11 C
B31.1 N
N See Note 5 tank inlet and discharge piping
- 21. Piping and C
D NNS 11 C
B31.1 N
N See Note S valves from reactor makeup water storage tank discharge WAPWR-5/E ANENONENT 1 4850e:Id NAY. 1996
\\
TABLE 3.2-1 (Sheet 7 of 41)
CLASSIFICATION OF STRUCTURES. COMPONENTS. ANO SYSTEMS (a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(1)
Principal Principal System Quality Safety Seismic Code Construction Safety and Components-Location Group Class Category Classification Code & Stds.
0-list Related Comments
- 22. Letdown piping C
C 3
I 3
III N
N See Note S to volume control tank
- 23. Charging piping C
C 3
I 3
III N
N See Note S l
from volume control tank
- 24. Nixed bed C
C 3
I 3
III N
N See Note 5 dominera112er piping and valves l
- 25. Safety-related C
NA 3
I E
NEMA N61 Y
Y valve operators
- 26. Seal Injection Heat Exchanger Tube Side C
8 3
I 3
Ill N
N Shell Side C
D NNS I
C TENA-R N
N
- 27. Seal Injection C
8 3
1 3
III N
N y
Filters
- 28. Reactor Coolant C
8 3
I 3
111 N
N Filters
- 29. RCP Seal 8
D NNS II C
B31.1 N
N Standpipes
- 30. Seal Return C
8 3
I 3
Ill N
N Filter ANENDNENT 1 WAPWR-5/E NAY, 1996 :
4RSRe 1rf L_
TABLE 31,.-(Sh:et 8 af 41)
CLASSIFICATION OF STRUCTURES. COMPONENTS. AND SYSTEMS (a)
(b)
(c)
(d)
(e)
(f)
(g).
(h)
(1)
Principal Principal System Quality Safety Seismic Code Construction Safety and Components Location Group.
Class Category Classification Code & Stds.
0-list Related Comments BORDN RECYCLE SYSTEN
- 1. Recycle evaporator C
D NNS 11 C
mfg N
N feed pumps 1
- 2. Recycle evaporator C
NA NNS 11 E
NERA MG1 N
N l
feed pump motors i
- 3. Boron recycle C
D NNS I
C 111 N
N holdup tanks
- 4. Recycle evaporator C
D NNS I
C Vill N
N feed demin-i eralizers
- 5. Recycle evaporator C
D NNS 11 C
VIII N
N condensate demineralizer
- 6. Recycle evaporator C
D NNS 11 C
Vill N
N 1
package
- 7. Recycle evaporator C
D NNS 11 C
Vill N
N condensate filter
- 8. Piping and valves C
D NNS 11 C
B31.1 N
N See Note S
- 9. Valve operators C
NA NNS II E
NERA ngl N
N 1
- 10. Instrumentation C
NA NNS 11 J
mfg N
N CONTAINNENT ISOLATIDN SYSTEN
- 1. Valves and piping B,C B
2 1
2 Ill Y
Y Selected valves and piping may be designed to ASME 111-1 l
1
- 2. Valve operators B,C NA 3
1 E
NENA MG1 Y
Y See Note S
- 3. Instrumentation 8,C NA 3
I J
mfg Y
Y and controls WAPWR-5/E AMENDMENT 1 485ae:1d MAY, 1986 w
o o
o o
TA8LE 3.2-1 (Sheet S of 41)
CLAS$lFICATION OF STR;;CTURES. COMPONENTS. AND SYSTEMS (a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(1)
Principal Principal System Quality Safety Seismic Code Construction Safety and Componenti Location Group Class Cateeory Classification Code & Stds.
0-list Related Comments SERVICE WATER SYSTEM j
Not included in the NPS COMPONENT COOLING WATER SYSTEM l
- 1. CCW surge tanks C
C 3
1 3
III Y
Y
- 2. CCW pumps C
C 3
1 3
Ill Y
Y
C 3
1 3
III Y
Y TEMA-R
- 4. CCW pump motors C
NA 3
1 E
NEMA MG1 Y
Y l
S. CCW chemical C
D NNS II C
API-650 N
N addition tanks
- 6. Chemical D
NNS 11 C
831.1 N
N See Note 5 addition tank valves and piping 1
+
- 7. All other C
3 1
3 Ill V
Y See Note S process valves and piping
- 8. Safety-related NA 3
I E
NEMA M61 Y
Y
{
valve operators j
- 9. Safety-related NA 3
I J
mig Y
Y instrumentation I
l SPENT FUEL COOLING AND FURIFICATION SYSTEM
C 3
1 3
III Y
Y TEMA-R
- 2. SFP pumps J
C 3
1 3
Ill Y
Y
- 3. SFP pump motors J
NA 3
1 E
NEMA MG1 Y
Y WAPWR-5/E AMfMONENT 1 i 4850e:1d NAY, 1986
O O
O O
TABLE 3.2-1 (Sheet 10 of 41)
CLASSIFICATION OF STRUCTURES. COMPONENTS. AND SYSTEMS (a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(1)
Principal Principal System Quality Safety Seismic Code Construction Safety and Components Location Group Class Category Classification Code & Stds.
0-list Related Ceauments l
- 4. Refueling water J
D NNS 11 C
mfg N
.N purification pump
- 5. Refueling water J
NA 3
II E
NEMA MG1 N
N purification pump motor
- 6. SFP demineralizer J
NA NNS II C
Ill N
N Note 1
- 7. SFP skimmer J
NA NNS 11 C
mig N
N pump
- 8. SFP sklauner J
NF.
NNS II C
Vill N
N a
filter
- 9. Purification J
NA NNS II C
831.1 N
N See Note S and skiauner-related valves 1
and piping l
- 10. Cooling-related J
C 3
1 3
III Y
Y See Note 5 valves and piping
- 11. Safety-related J
NA 3
I J
mfg Y
Y instrumentation
- 12. Safety-related J
NA 3
I E
NEMA MG1 Y
Y valve operators REACTOR MAKEUP WATER SYSTEM 1.
Makeup pumps J
D NNS II C
mig N
N Note 1 2.
Makeup pump J
NA NNS II E
NEMA MG1 N
N y
motors WAPWR-5/E AMENDMENT 1 4R%Re 1d MAy, 1936
O O
O O
O O
O TABLE 3.2-1 (Sheet 11 of 41)
CLASSIFICATION OF STRUCTURES. CONPONENTS. AND SYSTEMS (a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(1) 4 Principal Principal System Ovality Safety Seismic Code Construction Safety and Consonents (gpation Grouo Class Category Classification Code & Stds.
0-List Related Comments
]
- 3. Nakeup water J
D NNS II C
831.1 N
N See Note I process piping See Note S
]
and valves to 1
SFP l
- 4. Instrumentation J
NA NNS II J
mfg N
N
- 5. All other piping J
D NNS II C
B31.1 N
N See Note S 1
WASTE PROCESSING SYSTEN - LIQUID Note q
- 1. Waste holdup D
D NNS I
5 API-650 N
N tank
- 2. Waste evaporator D
D NNS II 5
afg N
N l
feed pump
- 3. Waste evaporator D
NA NNS II E
NENA NG1 N
N feed pump motor
- 4. Waste evaporator D
D NNS II 5
ofg N
N
- 5. Waste evaporator D
D NNS II 5
API-650 N
N concentrates holdup tank
- 6. Waste evaporator D
D NNS II 5
mfg N
h concentrates holdup tank pump
- 7. Waste evaporator D
D NNS II C
VIII N
N reagent tank
- 8. Waste evaporator D
D NNS II 5
III N
N condensate demineralizer
- 9. Waste evaporator D
D NNS II 5
III N
N condensate pump l
l WAPWR-S/E ANENDNENT 1 4858e:1d NAY 1986
O TA8LE 3.2-1 (Sheet 12 of 41)
CLASSIFICATION OF STRUCTURES. COMPONENTS. AND SYSTEMS l
(a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(1)
Principal Principal System Quality Safety Seismic Code Construction Safety and Components Location Group Class Category Classif1 Cation Code & Stds.
0-(1st Related Comments
- 10. Wste evaporator O
D NNS 11 5
Ill N
N condensate tank
- 11. Cheelcal drain D
D MS 11 C
Vill N
N tank
- 12. Chemical drain D
D MS 11 C
Vill N
N tank pump
- 13. Spent resin D
D NNS I
5 Ill N
N storage tank
- 14. Waste monitor D
D NNS II 5
111 N
N tank
- 15. Waste monitor D
D MS 11 5
N N
tank pump
- 16. Waste monitor D
NA NNS II E
NENA NG1 N
N i
7 tank pump motor
- 17. Laundry and D
D MS 11 5
Vill N
N hot shower tank
- 18. Laundry and O
D NNS 11 5
mig N
N hot shower tank pump
- 19. Reactor coolant 8
D NNS II 5
111 N
N drain tank l
- 20. Reactor coolant 8
0 NNS 11 5
III N
N drain tank pump i
a j
l
'l WAPWR-5/E ANENDMENT 1 4858e:1d MAY, 1986
O C
O O
1.tal E 3.2-1 (Sheet 13 of 41)
CLASSIFICATION OF SingCrieers. CONPONENTS. AND SYSTEMS (a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(1)
Principal Principal System Quality Safety Seismic Code Construction Safety and Comoonents Location Grouo Class Category Classification Code & Stds.
0-list Related Comments
- 21. Piping and valves D
D NNS II 5
B31.1 N
N See Note 5 from waste evap-orator and evaporator con-y densate demin-eralizer through evaporator condensate pump l
discharge valve
- 22. Instrumentation D
NA NNS II J
mfg N
N WASTE PROCESSING SYSTEN - G.tSEOUS I
l1
- 1. Gas decay tanks O
C NNS I
3 III N
N
- 2. Gas decay tank D
D NNS II C
afg N
N drain pump
- 3. Weste gas drain D
D NNS 11 C
VIII N
N filter
- 4. Waste gas com-D C
NWS 11 C
mfg N
N pressor package
- 5. Process piping D
C NNS II 3
III N
N See Note S and valves
- 6. Drain piping D
D NNS II C
B31.1 N
N See Note 5 and valves
- 7. Safety-related D
NA NNS II E
NENA NG1 N
N 1
valve operators
- 8. Safety-related D
NA NNS II J
mfg N
N instrumentation l
)
l WAPWR-5/E AMENDNENT 1 4858e:1d NAY, 1986
~
j O
O f
~
i TABLE 3.2-1 (Sheet 14 of 41)
)
CLASSIFICATION OF STRUCTURES. CONPONENTS. A4) SYSTEMS l
(a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(1)
Principal Principal System Quality Safety Seismic Code Construction Safety and Components location Group Class Cateeory Classification Code & Stds.
0-list Related Comments l
RAOWASTE VOLUNE REDUCTION AND SOLIDIFICATION SYSTEN Not included in the NP8 STEAN GENERATOR BLOWOOWN SYSTEN
- 1. Blowdown HXs J
G NNS 11 5
- VIII, N
N TENA-C
- 2. Steam generator J
J NHS II 5
afg N
N drain pump
- 3. Demineralizers J
D NNS II 5
VIII N
N j
j
- 4. Spent resin J
D NNS II 5
Vill N
N j
storage tank j
- 5. Spent resin J
D NNS II 5
mfg N
N j
slutte pump
- 6. Process valves J
D NNS II 5
831.1 N
N See Note S and piping outside j
containment j
- 7. Process valves 8
8 2
I 2
III Y
Y See Note 5 1
)
and piping inside l
containment through l
outer isolation valves i
- 8. Instr *unentation J
NA 3
II J
mfg N
N j
NAIN STEAN SYSTEN
- 1. Steam generator 8
8 2
1 2
Ill Y
Y (shell side) l I
WAPWR-5/E ANENDNENT 1 i
4858e:1d NAY, 1986 i
o j
TABLE 3.2-1 (Sheet 15 of 41)
CLASSIFICATION OF STRUCTURES. COMPONENTS. AND SYSTEMS 1
l i
(a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(1) l Principal l
Principal system Ouality Safety seismic Code Construction safety l
_and Components location Group Class CateGorV Classification Code & Stds.
0-list Related
[omments 1
- 2. Piping from SG B
B 2
I 2
III Y
Y See Note 5 i
to S g y restraint 1
- 3. Safety valves C
B 2
I 2
III Y
Y
- 4. Atmospheric C
8 2
1 2
III Y
Y relief valves
- 5. Atmospheric C
NA 3
I E
NEMA M61 Y
Y relief valves operators
- 6. Main steam C
B 2
I 2
III Y
Y l
1 solation valves l
- 7. Main steam C
NA 3
I E
ofg Y
Y l
1 solation valve actuators
- 8. Safety-related C
NA 3
I E
NEMA MG1 Y
Y j
valve operators
- g. Mechanical 8,C 8
2 I
2 III Y
Y pressure, flow, and level instruments l
- 10. Safety-related 8,C NA 3
I J
mig Y
Y instrumentation
- 11. Steam flow B
B 2
I 2
III Y
Y limiters EMERGENCY FEEDWATER SYSTEM
- 1. Emergency feed C
C 3
I 3
III Y
Y pump turbine
- 2. Emergency feed C
C 3
I 3
III Y
Y pumps WAPWR-5/E AMEN 0 MENT 1 l
4858e:1d MAY, 1986
i O
O l
TABLE 3.2-1 (Sheet 16 of 41) i CLASSIFICATION OF STRUCTUaES. COMPONENTS. AND SYSTEMS l
(a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(1)
Principal l
Principal System Quality Safety Seismic Code Construction Safety j
and Consonents Location Group Class Category Classification Code & Stds.
0-list Related Comments
- 3. Emergency feed C
NA 3
I E
NEMA MGI Y
Y motors
- 4. Piping up 8,C C
3 I
3 III Y
Y See Note 5 to SG feed admission MOVs
- 5. Piping and BC 8
2 I
2 III Y
Y See Note S valves including y
admission MOVs to SJ l
- 6. Pug suction 8,C C
3 I
3 Y
Y See Note S I
valves and l
piping l
T. Safety-related 8,C NA 3
I J
mig Y
Y instrumentation 1
- 8. EFWS tank 8
C 3
I 3
III Y
Y 1
START-UP FEEDWATER SYSTER Not included in the NPS 1
l MAIN FEEDWATER SYSTEM I
1 j
- 1. Main feed line T
8 2
1 2
III Y
Y
{
isolation valves l
- 2. Main feed line T
NA 3
I E
NEMA MG1 Y
Y isolation I
)
valve motors i
i WAPWR-5/E AMEN 0 MENT 1 j
4R5Re:1d MAY, 1986
O TABLE 3.2-1 (Sheet 17 of 41) j CLASSIFICATION OF STRUCTURES. CORPOWENTS. ANO SYSTEMS (a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(1)
Principal j
Principal System Quality Safety Seismic Code Construction Safety 1
and Consonents Location Group Class Category Classification Code & Stds.
0-list Related Comuments
- 3. Main and auxiliary T
8 2
1 2
Ill Y
Y.
feed inlet I
?
- 4. Piping T
B 2
1 2
III Y
Y See Note S l1
- 5. Feed isolation T
NA 3
I J
mfg Y
Y instrumentation l
and controls j
- 6. Safety-related T
NA 3
I E
NEMA MG1 Y
Y valve motors
{
I POWER CONVER$10N SYSTEM Not included in NPS CONDENSER AIR EJECTOR SYSTEM Not included in NPS CIRCULATING WATER SYSTEM Not included in NPB INTAKE STRUCTURE SYSTEMS Not included in NPS CIRCULATING WATER CHEMICAL INJECTION SYSTEM Not included in NPS CONDENSATE CHEMICAL INJECTION SYSTEM Not included in NPS CONDENSATE FILTER DEMINERALIZER SYSTEM Not included in NPS I
PLANT MAKEUP WATER SYSTEM Not included in NPB 1
WAPWR-S/E AMENONENT 1 4858e:1d MAY, 1986
I TABLE 3.2-1 (Sheet 18 of 41) l CLASSIFICATION OF STRUCTURES. COMPONENTS. ANO SYSTEMS 2
(a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(1)
Principal l
Principal System Quality Safety Seismic Code Construction Safety and Consonents Location Grouo Class Category Classification Code & Stds.
0-list Related
[omments l
DEMINERALIZED WATER SYSTEM Not included in NPS
(
DIESEL GENERATOR SYSTF M l1
- 1. Day tanks K
C 3
1 C
III Y
Y
- 2. Fuel transfer pumps K
C 3
I 3
III Y
Y l
- 3. Fuel transfer pump K
C 3
I E
NEMA M61 Y
Y j
motors
{
- 4. Fuel filters K
C 3
I C
afg Y
Y l
- 5. Lube oil HK K
C 3
I C
III Y
Y
- 6. Lube oil heater K
C 3
I C
afg Y
Y Casing is ASME Vill
- 7. Lube oil filters K
C 3
I C
III Y
Y
- 8. Cooling jacket K
NA 3
I C
afg Y
Y Casing is ASME VIII l
water heater
- g. Air compressors K
C 3
11 C
mfg N
N
- 10. Air receivers K
C 3
I 3
Ill Y
Y
- 11. Air compressor K
C 3
II C
mig N
N af ter coolers j
- 12. Safety-related K
NA 3
I J
mfg Y
Y j
instrumentation
- 13. Diesel generators K
C 3
I C.E DEMA. NEMA Y
Y
- 14. Engine auxiliaries K
C 3
I C
111 Y
Y See Note 5 1
piping and valves
C 3
I C
III Y
Y j
- 16. Fuel oil storage O
C 3
I C
III Y
Y
]
tanks i
WAPWR-S/E AMEN 0 MENT I 4858e:ld MAY, 1986
O O
O O
s i
j TABLE 3.2-1 (Sheet 19 of 41)
CLASSIFICATION OF STRUCTURES. COMPONENTS. AND SYSTEMS (a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(1) i Principal Principal System Quality Safety Seismic Code Construction Safety and Components Location Grouo Class Category Classification Code & Stds.
0-list Related Comments l
FIRE PROTECTION SYSTEMS Note p l
i l
- 1. Diesel driven J
NA NNS Il 1
NFPA N
N ftre pumps l
- 2. Diesel engines J
NA NNS II 1
afg N
N
- 3. Motor driven J
NA MS 11 1
NFPA N
N fire pump
- 4. Pump motors J
NA MS II E
NERA MG1 N
N
- 5. Diesel fuel oil tanks 0 NA MS II 7
NFPA N
N
- 6. Water storage tanks 0
NA MS II 7
NFPA N
N
- 7. Water system piping V8 NA NNS II 7
NFPA N
N See Note 5 j
and valves 1
- 8. Halon system piping.
V8 NA MS 11 7
NFPA N
N See Note S valves, and components
- 9. Instrumentation V8 NA MS II J
mfg N
N i
AUXILIARY GAS SYSTEMS (N, H, AND 0 I 2
2 2
I Not included in NP8 l
RCS LIQUID SAMPLING SYSTEM j
- 1. Process sample valves C D
MS II 4
B31.1 N
N See Note o
)
and piping See Note 5 y
- 2. RCS sample valves and B B
2 1
2 111 Y
Y See Note 5 piping through outside
]
containment isolation
)
valve I
l WAPWR-5/E AMENDMENT 1 4858e:1d MAY, 1986 4
(
l TABLE 3.2-1 (Sheet 20 of 41)
~
CLASSIFICATION OF STRUCTURES. CONPONENTS. AND SYSTE!E i
(a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(1)
Principal
. Principal Systee Quality Safety Seismic Code Construction Safety I
and Commonents Location Grovo Class Cateeorv Classification Code & Stds.
0-list nelated
(_omments
- 3. Sample vessels C
D MS II 4
VIII N
N
- 4. Sample coolers C
D MS II 4
VIII N
N
- 5. Gross failed fuel C
D NNS II 4
ofg N
N detector
- 6. Instrumentation C
NA MS II J
mfg N
N i
RCS GAS SAMPLING SYSTEN i
i j
- 1. Sample vessels C
D MS II 4
VIII N
N
- 2. Valves and piping C
D MS 4
B31.1 N
N See Note S inside vent hood l
- 3. Instrumentation C
NA MS II J
mfg N
N l
POST-ACCIDENT SAMPLING SYSTEN I
i
- 1. PASS panel C
D NNS II 4
B31.1 N
N (mechanical portions)
- 2. PASS panel C
NA MS II J
mfg N
N instrumentation
- 3. Sample pumps C
D NNS II 4
ofg N
N l
- 4. Sample piping C
D MS II 4
531.1 N
N See Note 5 and valves i
1
- 5. Containment B
8 2
I 2
III Y
Y See Note 5 penetration piping and valves I
1 W4PWR-5/E ANENONCNT 1 i
1 4858e:1d NAY, 1986
O J
TAGLE 3.2-1 (Sheet 21 of 41)
CLASSIFICATION OF STRUCTURES. COMPouENTS. AND SYSTEMS i
(a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(1)
I Principal Principal System Osality Safety Seismic Code Construction Safety and Commenents Location Group Class Category Classification Code & Stds.
0-t15%
Related Cosmients 4
CONTAINNENT. AURILIARY BUILDING, AND MISCELLANEOUS DRAIN SYSTEMS i
- 1. Radioactive drain D
D MS II 4
afg N
N i
sump pumps
- 2. Reactor cavity B
D MS I
4 afg N
N sump pumps i
- 3. Containment B
D MS I
4 afg N
N sump pumps
- 4. Penetration room C
D MS I
4 ofg N
N
{
some pumps
- 5. Aux 111ary building J
D MS 4
afg N
N j
sump pumps
- 6. Component cooling C
D MS II 4
API-650 N
N j
water drain tank j
- 7. Component cooling C
D MS II 4
ofg N
N j
water drain tank pump
(
B. Diesel building oily K
D MS II 4
afg N
N l
waste sump pumps
- 9. Equipment drain C
D MS II 4
API-640 N
N l
tant j
- 10. Floor drain tank C
D MS 11 4
API-650 N
N l
- 11. Containment reactor 8,C NA MS I
E ofg N
N cavity and penetration room sump pump motors l
- 12. All other pump motors C NA MS II E
NEMA MG1 N
N f
- 13. Instrumentation C
NA MS II.
J ofg N
N
- 14. All other valves C
D MS II 4
331.1 N
N See Note S y
l and all piping j
I i
WAPWR-5/E ANENOMENT 1 4858e:1d MAY, 1986 l
C O
TASLE 3.2-1 (Sheet 22 of 41)
CLASSIFICATION OF STRUCTURES. COMP 0NENTS. AN8 SYSTEMS (a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(1)
Principal Principal Systen Quality Safety Seismic Code Construction Safety and Consonents Location Group Class Cateeory Classification Code & 5tds.
0-ttst Related Comments INSTRUMENT AN8 SERVICE Alp SYSTEM
- 1. Air compressors J
NA MS II C
afg N
N
- 2. Air compressor motors J NA MS II E
NEMA NG1 N
N
- 3. Air receivers J
NA MS II C
VIII N
N
- 4. Aftercoolers J
NA MS II C
VIII N
N
- 5. Motsture separators J
NA MS II C
afg N
N
- 6. Service air filters J
NA WS II C
mfg N
N
- 1. Instrument air filters J NA MS II C
afg N
N
- 8. Service air dryers J
NA MS II C
afg N
N
- g. Instrument air dryers J NA MS II C
mfg N
N
- 10. Safety-related piping V8 C
3 I
3 III Y
Y See Note S and valves (other than containment isolation) 1
- 11. Containment 8
8 2
I 2
III Y
Y See Note S penetration piping and valves
- 12. All other piping V8 NA MS II 4
831.1 N
N See Note 5 and valves
- 13. Instrumentation V8 NA MS II J
mfg N
N REACTOR COOLANT SYSTEN LEAK DETECTION SYSTEM
- 1. Radiation monitors B
NA MS I
J mfg N
N
- 2. Condensate measuring 8
NA MS II J
mig N
N j
instruments I
i WAPWR-S/E AMENDNENT 1 4858e:1d NAY, 1986
TABLE (Sheet 23 af 41)
CLASSIFICATION OF STRUCTURES. COMPONC"TS. AND SYSTEMS (a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(1)
Principal Principal System Quality Safety Seismic Code Construction Safety
.and Components Location
_ Group Class Catego[y Classification Code & Stds.
0-List Related Comments i
- 3. Condensate measuring B
D NNS II 4
B31.1 N
N See Note 5 1
i piping and valves
- 4. Humidity detectors B
NA NNS II J
mfg N
N j
- 5. Tank and sump level B
D NNS II J
mfg N
N 1
instruments i
FUEL HANOLING BUILDING DRAIN SYSTEM
- 1. Sump pumps F
0 NNS II 4
afg N
N
- 2. Sump pump motors F
NA NNS II E
NEMA MG1 N
N l
- 3..'iping and valves F
D NNS II 4
B31.1 N
N See Note S l
1
- 4. Instrumentation F
NA NNS II J
mfg N
N l
CONTAINMENT AIR COOLING SYSTEM
- 1. Cooling fans B
B 3
I C
AMCA Y
Y l
- 2. Fan motors B
B 3
I E
NEMA MG1 Y
Y i
- 3. Coolers B
B 2
I 2
III Y
Y 1
- 4. Ductwork B
B 3
I C
ANSI N509 Y
Y
- 5. Dampers B
B 3
I C
ANSI N509 Y
Y 1
1
- 6. Ormper motors B
B 3
I E
NEMA MG1 Y
Y
- 7. Safety-related B
B 3
I J
mig Y
Y I
instrumentation i
i l
CONTAINMENT PREACCESS FILTER SYSTEM l
- 1. Fans B
D NNS II C
AMCA N
N q
- 2. Fan motors B
NA NNS II E
NEMA M61 N
N I
4 1
WAPWR-5/E AMENDMENT 1 4858e:1d MAY, 1986 1
l
TABLE 3.2-heet 24 ef 41)
CLASSIFICATION OF STRUCTURES. COMPONE"TS. AND SYSTEMS (a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(1)
Principal Principal System Quality Safety Seismic Code Construction Safety and Components Location Group Class Category Classification Code & Stds.
0-List Related Comments
- 3. HEPA filters B
D NNS 11 C
ANSI N509 N
N
- 4. Charcoal filters B
D NNS C
ANSI N509 N
N
- 5. Heaters B
D Nh5 II E
UL M
N
- 6. Moisture eliminators B
D NNS 11 C
ANSI M509 N
N
- 7. Instrumentation B
NA NNS 11 J
mfg N
N CONTAINMENT POST-LOCA PURGE EXHAUST SYSTEM
- 1. Containment B
B 2
1 2
III Y
Y penetration ducting
- 2. Isolation dampers B
B 2
1 2
III Y
Y l
- 3. Isolation damper B
NA 3
1 E
NEMA MG1 Y
Y motors
- 4. Heaters C
NA NNS II E
UL N
N
- 5. Motsture eliminators C
D NNS 11 C
ANSI N509 N
N
- 6. HEPA filters C
D NNS 11 C
ANSI N509 N
N
- 7. Charcoal filters C
D NNS C
ANSI N509 N
N i
- 8. Post-LOCA purge C
D NNS C
ANSI N509 N
N exhaust unit housing
- 9. Instrumentation C
NA NNS II J
mfg N
N CONTAINMENT CRDM COOLING SYSTEM
- 1. Fans B
NA NNS 11 C
AMCA N
N
- 2. Fan motors B
NA NNS II E
NEMA MGl N
N
- 3. Ductwork B
NA NNS 11 C
SMACNA N
N
- 4. Instrumentation B,C NA NNS 11 J
mfg N
N WAPWR-S/E AMENDMENT 1 4858e:Id MAY,1986
TABLE 3.2-1 et 25 of 41)
CLASSIFICATION OF STRUCTURES. COMPONENTS. A"O SYSTEMS (a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(1)
Principal Principal System Quality Safety Seismic Code construction Safety and Components Location Group Class Category Classification Code & Stds.
0-List R? lated Coassents H RECOMBINER AND MONITORING SYSTEM 2
- 1. Penetration piping B
8 2
1 2
Y Y
See Note S and valves
- 2. Other piping C
B 3
I 3
Ill Y
Y See Note 5 1
and valves
- 3. H m nitors C
B 3
I J
mfg Y
Y 2
- 4. H recombiners C
B 3
I C
afg Y
Y 2
- 5. Recombiner B,C B
3 I
J mfg Y
Y l
instrumentation l
l REACTOR EXTERNAL BUILDING HVAC SYSTEM
- 1. Ventilation fans C
NA NNS 11 C
AMCA N
N
- 2. Ventilation fan C
NA NNS II E
NEMA MG1 N
N motors
- 3. Ductwork C
NA NNS 11 C
ANSI M509 N
N
- 4. Dampers C
NA NNS 11 C
ANSI M509 N
N
- 5. Dampar motors T
NA NNS 11 E
NEMA MG1 N
N
- 6. Instrumentation C
NA NNS II J
mfg N
N CONTROL ROOL HVAC SYSTEM (ESSENTIAL PORTION)
- 1. Filter ur.it fans G
NA 3
I C
AMCA Y
Y
- 2. Filter unit f ans G
NA 3
I E
NEMA MG1 Y
Y motors
- 3. Return air fans G
NA 3
I C
AMCA Y
Y
- 4. Return air fans motor G NA 3
I E
NEMA MG1 Y
Y WAPWR-S/E AMENDMENT 1 4d58e:1d MAY, 1986
i TABLE 3.2-1 (Sheet 26 af 41)
CLASSIFICATION OF STRUCTURES. COMPONENTS. AND SYSTEMS T
(a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(1)
Principal Principal System Quality Safety Seismic Code Construction Safety 4
j and Commenents location _ Group Class Category Classification Code & Stds.
0-List Related Comments l
1 1
- 5. Motsture eliminators G
NA 3
I C
ANSI N509 Y
Y l
- 6. Heaters G
MA 3
I E
UL Y
Y
- 7. HEPA filters G
NA 3
I C
ANSI h509 Y
Y
+
- 8. Charcoal filters G
NA 3
I C
ANSI N509 Y
Y
)
- 9. Cooling colls G
C 3
I 3
III Y
Y
)
- 10. Dampers G
NA 3
I C
AN3I N509 Y
Y
- 11. Damper motors G
NA 3
I E
NEMA MG1 Y
Y i
- 12. Ductwork G
NA 3
I C
ANSI N509 Y
Y
- 13. 4fety-related G
NA 3
I J
mfg Y
't i
,nstrumentation ESSCTIAL SAFETY FACILITY AREA KVAC SYSTEM i
- 1. Battery room exhaust I
NA 3
I C
AMCA Y
Y l
i fans 1
- 2. Battery room exhaust I
NA 3
I E
NEMA MG1 Y
Y fan motors
- 3. A/C unit fans I
NA 3
I C
AMCA Y
Y
- 4. A/C unit fan motors I
NA 3
I E
NEMA MG1 Y
Y
- 5. Cooling coils I
C 3
I 3
III Y
Y
- 6. Pref 11ters I
NA 3
I C
ASHRAE Y
Y
- 7. Ductwork I
NA 3
I C
ANSI N509 Y
Y
- 8. Dampers I
NA 3
I C
ANSI M509 Y
Y
- 9. Damper motors I
NA 3
I E
NEMA MG1 Y
Y
- 10. Safety-related I
NA 3
I J
mfg Y
Y instrumentation l
1 l
l teAPWR-S/E AMENDMENT 1 4858e:1d MAY 1986
i n
i TABLE 3.2-1 % 4t 25 af 41)
~
I g ASSIFICATION OF STRUCTURES. COMPONENTS. AND SYSTEMS (a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(1)
Principal Principal System Quality Safety Seismic Code Construction Safety
.and Components Location
_ Group _
Class Categorv Classification Code & Stds.
0-List Related Comments k
H RECOMBINE 2 AND MONITORING SYSTEM 2
i j
- 1. Penetration piping B
B 2
I 2
Y Y
See Note S End valves
- 2. Other piping C
B 3
I 3
III Y
Y See Note S 1
and valves
- 3. H m nitors C
B 3
1 J
mfg Y
Y 2
- 4. H recombiners C
B 3
I C
mfg Y
Y 2
J
- 5. Recombiner 8,C B
3 I
J mfg Y
Y instrumentation REACTOR EXTERNAL BUILDING HVAC SYSTEM i
i t
- 1. Ventilation fans C
NA MS II C
AMCA N
N
- 2. Ventilation fan C
NA ms E
NEMA MG1 N
N l
motors i
}
- 3. Ductwork C
NA ms II C
ANSI N509 N
N
- 4. Campers C
NA mS II C
ANSI M50g N
N
- 5. Damper motors f
NA MS II E
NEMA MG1 N
N 1
l
- 6. Instrumentation C
NA ms II J
mfg N
N CONTROL ROOL HVAC SYSTEM (ESSENTIAL PORTION)
- 1. Filter unit fans G
NA 3
I C
AMCA Y
Y
- 2. Filter unit fans G
NA 3
I E
NEMA MG1 Y
Y motors
- 3. R2 turn air fans G
NA 3
I C
AMCA Y
Y
- 4. R2 turn air fans motor G MA 3
I E
NEMA MG1 Y
Y WAPWR-5/E 4858e:1d AMENDNENT 1 MAY, 1986
TABLE 3.2-1 (Sheet 26 ef 41)
CLASSIFICATION OF STRUCTURES. COMPONENTS. ANO SYSTEMS j
(a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(1)
Principal l
Principal System Ouality Safety Seismic Code Construction Safety 4
.and Components Location _ Group Class Category Classification Code & Stds.
0-!.ist Related Comments j
- 5. Moisture eliminators G
MA 3
I C
ANSI M509 Y
Y j
- 6. Heaters G
NA 3
I E
UL Y
Y
- 7. HEPA filters G
NA 3
I C
ANSI M509 Y
Y l
- 8. Charcoal filters G
MA 3
I C
AN3I M509 Y
Y
- 9. Cooling coils G
C 3
I 3
III Y
Y
- 10. Dampers G
NA 3
I C
ANSI N509 Y
Y
- 11. Damper motors G
NA 3
I E
NEMA MG1 Y
Y l
- 12. Ductwork G
NA 3
I C
ANSI N509 Y
Y l
- 13. Safety-related G
NA
-3 I
J mfg Y
Y instrumentation ESSECTIAL SAFETY FACILITY AREA HVAC SYSTEM i
I l
- 1. Battery room exhaust I
NA 3
I C
AMCA Y
Y fans
- 2. Battery room exhaust I
NA 3
I E
NEMA MG1 Y
Y fan motors
- 3. A/C unit fans I
NA 3
I C
AMCA Y
Y
- 4. A/C unit fan motcrs I
NA 3
I E
NEMA MG1 Y
Y
- 5. Cooling coils I
C 3
I 3
III Y
Y
- 6. Pref 11ters I
NA 3
I C
ASHRAE Y
Y
- 7. Ductwork I
NA 3
I C
ANSI N509 Y
Y
- 8. Dampers I
NA 3
I C
ANSI M509 Y
Y I
- 9. Damper motors I
NA 3
I E
NEMA MG1 Y
Y
- 10. Safety-related I
MA 3
I J
mfg Y
Y l
Instrumentation i
l l
WAPWR-5/E AMENDMENT 1 4858a:1d MAY, 1986
i O
O
~
TABLE 3.2-1 (Sheet 27 of 41) l CLASSIFICATION OF STRUCTURES. COMPONENTS. AND SYSTEMS (a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(1)
Principal Principal System Quality Safety Seismic Code Construction Safety i
and Components Location
_ Group Class Category Classification Code & Stds.
0-List Related comuments t
I CONTROL COMPLEX AREA CA8LE SPREADING ROOM HVAC SYSTEM
- 1. Cable spreading G
NA NNS 11 C
AMCA N
N room A/C fans
- 2. Cable spreading room G NA NNS 11 E
NEMA MG1 N
N l
A/C fan motors
- 3. Pref 11ters G
NA NNS 11 C
ASHRAE N
N
- 4. All other coolers G
NA NNS 11 C
ARI N
N
- 5. Electric duct heaters G NA NNS 11 E
UL N
N 1
- 6. All other ductwork G
NA NNS 11 C
SMACNA N
N j
- 1. All other G
NA NNS 11 J
mig N
N instrumentation FUEL HANDLING AREA POST-ACCIDENT EXHAUST SYSTEM l
- 1. Fans F
NA 3
1 C
ANCA Y
Y
- 2. Fan motors F
NA 3
1 E
NEMA MC1 Y
Y
- 3. Motsture eliminators F
NA 3
I C
ANSI N509 Y
Y
- 4. Heaters F
NA 3
1 E
UL Y
Y
- 5. HEPA filters F
NA 3
1 C
ANSI N509 Y
Y
- 6. Charcoal filters F
NA 3
I C
ANSI N509 Y
Y
- 7. Ductwork F
NA 3
I C
ANSI N509 Y
Y I
- 8. Dampers F
NA 3
I C
ANSI N509 Y
Y j
- 9. Dampers motors F
NA 3
1 E
NEMA MG1 Y
Y
- 10. Safety-related F
NA 3
I J
mfg Y
Y instrumentation l
J l
i I
WAPWR-5/E ANENDNENT 1 4858e:1d MAY.1986
TABLE 3.2-1 (Sheet 28 of 41) l CLASSIFICATION OF STRUCTURES. COMPONENTS. AND SYSTEMS (a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(1)
Principal i
Principal System Quality Safety Seismic Code Construction Safety and Components location Group Class Category Classif 1110!! Code & Stds.
0-List Related Comuments REACTOR EXTERNAL BUILDING OUTSIDE AIR SUPPLY. NORMAL HVAC, RADIDACTIVE FILTER EXHAUST. AND CONTINUOUS EXHAUST SYSTEMS I
]
- 1. Exhaust unit fans C
NA NNS 11 C
AMCA N
N
- 2. Exhaust unit C
NA NNS II E
NEMA MG1 N
N fan motors I
- 3. A/C fans C
NA NNS 11 C
AMCA N
N
- 4. A/C fan motors C
NA NNS II E
NEMA MG1 N
N
- 5. HEPA filters C
NA NNS 11 C
ANSI N509 N
N
- 6. Charcoal filters C
NA NNS 11 C
ANSI N509 N
N j
- 7. Electric heaters C
NA NNS II E
UL M
N S. Cooling coils C
NA NNS C
ARI N
N j
- 9. DuctWrk C
NA NNS 11 C
SMACNA N
N l
- 10. Dampers C
MA NNS II C
. ANSI N509 N
N j
- 11. Daaper motors C
NA NNS II E
NEMA MG1 N
N I
12'. Instrumentation C
NA NNS II J
mfg N
N PIPING PENETRATION VENTILATION SYSTEM 1
- 1. Restraint cooling fans C NA NNS C
AMCA N
N
- 2. Restraint cooling C
NA NNS II E
NEMA MG1 N
N fan motors
- 3. Ductwork C
NA NNS 11 C
SMACNA N
N j
- 4. Backdraf t dampers C
NA NNS II C
ANSI N509 N
N
- 5. Instrumentation C
NA NNS II J
mfg N
N PIPING PENETRATION FILTER EXHAUST SYSTEM i
i l
- 1. Fans C
NA 3
I C
AMCA Y
Y
- 2. Fan motors C
NA 3
I E
NEMA MG1 Y
Y j
[dAPWR-S/E AMENDMENT 1 4858e:1d MAY, 1986
O O
O
)
l TA8LE 3.2-1 (Sheet 29 of 41)
CLASSIFICATION OF STRUCTURES. COMPONENTS. AND SYSTEMS (a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(1)
I Principal Principal System Quality Safety Seismic Code construction Safety l
and Cassonents Location Group Class Cateeory Classification Code & Stds.
0-list Related Comments
- 3. HEPA filters C
NA 3
I C
ANSI N509 Y
Y
- 4. Charcoal filters C
NA 3
I C
ANSI N509 Y
Y
- 5. Dampers C
NA 3
I C
ANSI N509 Y
Y v
- 6. Damper motors C
NA 3
I E
NEMA M1 Y
Y i
- 7. Sectwork C
NA 3
I C
ANSI N509 Y
Y
- 8. Area coolers C
C 3
1 3
III Y
Y
- 9. Safety-related C
NA 3
I J
mfg Y
Y l
instrumentation
}
ELECTRICAL PENETRATION FILTER EXHAUST SYSTEM i
- 1. Fans C
NA 3
I C
AMCA Y
Y
- 2. Fan notors C
NA 3
I E
NEMA M1 Y
Y
- 3. HEPA filters C
NA 3
I C
ANSI N509 Y
Y
- 4. Charcoal filters C
NA 3
I C
ANSI N509 Y
Y l
- 5. Ductwork C
NA 3
I C
ANSI N509 Y
Y r
I l
- 6. Dampers C
- A 3
I C
ANSI N509 Y
Y
- 7. Damper motors C
NA 3
1 E
NENA M1 Y
Y t
j
- 8. Safety-related C
NA 3
I J
mfg Y
Y instrumentatton l
DIESEL GENERATOR SUILDI M HVAC SYSTEM i
)
- 1. ESF exhaust fans K
NA 3
I C
AMCA Y
Y I
- 2. ESF exhaust fan K
NA 3
I E
NEMA M1 Y
Y j
motors f
- 3. ESF ductwork K
NA 3
I C
ANSI N509 Y
Y i
I WAPWR-5/E AMEN 0 MENT 1 4158e:Id NAY, 1996
I l
I TABLE 3.2-1 (Sheet 30 of 41) i CLASSIFICATION OF STRUCTURES. COMP 0NENTS. ANO SYSTEMS 1
(a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(1)
Principal Principal Systees Quality Safety seismic Code Construction Safety 4
.and Com onents_
tocation Group __ Class Cateeory Classification Code & Stds.
0-Eist Related Coments i
- 4. E5F dampers K
NA 3
I C
ANSI N509 Y
Y I
- 5. E5F damper motors K
NA 3
1 E
NEM NG1 Y
Y l
j
- 6. ESF instrumentation K
NA 3
I J
mfg Y
Y MI3 CONTROL 804RO Note j, k l
l
- 1. Mand switches and G
NA 3
I J
mfg Y
Y I
controls for safety-
[
related egulpment i
- 2. All other instru-G NA 6
I J
mig N
N l
ments and controls I
NUCLEAR INSTRUNENTATION SYSTEM i
I I
- 1. All instruments B,C NA 3
I J
mfg Y
Y inputting to reactor protection l
system i
l PROCESS CONTROL SYSTEM l
i j
j
- 1. N555 safety-related 3,C NA 3
I J
mfg Y
Y instrumentation and l
controls l
I 1
l
}
i WA M -5/E AMENOMENT 1 4858e:Id MAY, 1986 4
. ~... - - _ _.
- - ~ _ -. - -
1 L
TAttE 3.2-1 (Sheet 31 of 41) l CLASSIFICATION OF STRUCTUNES. COMPONENTS. AND SYSTEst5 (a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(1)
Principal i
Principal System Oma11ty Safety seismic Code Construction safety and Conocents_
Location Grous Class Category Classification Code & Stds.
0-List celated Comments I
i P90TECTION SYSTER i
t
- 1. Protection instra-BC NA 3
I J
mfg Y
Y j
mentation and controls
(
1 I
ROS CONTROL POWER SYSTER
(
- 1. Reactor trip I
NA 3
I E
mig Y
Y a
f switchgear l
l
- 2. Other switchgear I
IIA INes II E
ofg N
N B00 CONTROL SYSTER f
- 1. Red control I
IIA NNS I
J mfg N
N 1
equipment j
)
l 300 POSITION IlseICATION SYSTER j
l
- 1. Rod position I
10 4 IIsis J
mfg N
N 1r.strumentation l
)
RASIATION IIONITORIIe6 SYSTER j
- 1. Safety-related V9 lea 3
I J
mfg Y
Y portions I
l I
I i
WAPWR-5/E AftEleOftENT 1 j
4858e:1d NAY, 1986
N 5
O TABLE 3.2-1 (Sheet 32 of 41)
CLASSIFICATION OF STRUCTURES. COMPONENTS. ANO SYSTEMS (a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(1)
Principal
^ '
Principal System Quality Safety Seismic Code Construction Safety 1
M Consonents Location Grouo Class Category Classification Code & Stds.
0-List Related Comments i
-s i
- 2. Nonsafety-related, VB NA NNS I
J mig N
N seismic Category 1 portions
- 3. Other portions VB NA NNS 11 J
mig N
N ESF ACTUATION SYSTEN
- 1. All portions B,C NA 3
I J
mfg Y
Y REACTOR INSTRUMENTATION
- 1. All portions B,C NA 3
I J
mig Y
Y inputting to reactor pro *ection
- 2. Other portions B,C NA NNS 11 J
mfg N
N REACTOR CONTROL SYSTEN l
- 1. Protection-related B,C NA 3
I J
mig Y
Y portions
- 2. 0*her portions B,C NA NNS 11 J
mig N
N POST-ACCIDENT NONITORING SYSTEN Note k
- 1. Safety-related B,C NA 3
I J
mig Y
Y portions l
WAPWR-5/E AMEN 0 MENT 1 4858e:1d MAY, 1986
~
c O
O v
TABLE 3.2-1 (Sheet 33 of 41)
CLASSIFICATION OF STRUCTURES. COMPONENTS. AND SYSTEMS (a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(1)
Principal Principal System Quality Safety seismic Code Construction Safety and Components.
Location Group Class Category Classification Code & Stds.
0-List Related Comments
- 2. Nonsafety-related, 8,C NA NNS I
J mig N
N seismic Category 1 portions
- 3. Other portions B,C NA NNS II J
mfg N
N I
PLANT AUXILIARY CONTROL BOARDS
- 1. Safety-related C
NA 3
1 J
mfg Y
Y j
portions
- 2. Nonsafety-related C
NA NNS 11 J
mfg N
N portions INCORE INSTRUMENTATION r
- 1. All portions 8,C NA NNS I
J mig N
N r
COMPUTER SYSTEN j
- 1. All portions VB NA NNS I
J mfg N
N l
ANNUNCIATOR SYSTEN
- 1. All portions VB NA NNS I
J mig N
N SEISMIC NONITORING EQUIPMENT
- 1. All portions VB NA NNS I
J mfg N
N WAPWR-5/E AMENDMENT 1 4858e:1d MAY, 1986
O v
TABLE 3.2-1 (Sheet 34 of 41)
CLASSIFICATION OF STRUCTURES. ConPOWENTS. AND SYS1 EMS (a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(1)
Principal Principal System Quality Safety Seismic Code construction Safety and Components Location Group Class Category Classification Code & Stds.
0-List Related Cosaments AC SYSTEM - 480 V l
- 1. 4160/480 V N
NA 3
1 E
mfg Y
Y transformers
- 2. Load centers C
NA 3
1 E
mig Y
Y
- 3. Motor control C
NA 3
1 E
mfg Y
Y centers l
- 4. Instrumentation C
NA 3
1 E
mfg Y
Y and control i
AC SYSTEM - 4160 V
- 1. 4.16 kV buses and C
NA 3
1 E
mfg Y
Y switchgear
- 2. Instrumentation C
NA 3
1 E
mfg Y
Y and controls l
DC SYSTEM - CLASS 1E
- 1. Batteries C
NA 3
1 E
mfg Y
Y t
- 2. Chargers C
NA 3
1 E
mfg Y
Y
- 3. Breakers, bus work.
C NA 3
1 E
mfg Y
Y and switchgear
- 4. Instrumentation C
MA 3
1 E
mfg Y
Y j
and controls
- 5. Motor control C
NA 3
1 E
mig Y
Y center
- 6. Distribution panels C
NA 3
1 E
mig Y
Y 4
WAPWR-5/E AMENDMENT 1 4858e:1d MAY, 1986
TABLE 3.2-1 (Sheet 35 of 41)
C.LASSIFICATION OF STRUCTURES. COMPONENTS. AND SYSTEMS (a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(1)
Principal Principal System Quality Safety Seismic Code Construction Safety and Components Location Group Class Category Classification Code & Stds.
0-List Related Comments 120-V ac POWER SYSTEN - CLASS 1E
- 1. Transfonners C
NA 3
1 E
ofg Y
Y
- 2. Breakers, bus work, C
NA 3
1 E
mfg Y
Y and switchgear
- 3. dc-ac inverters C
NA 3
I E
ofg Y
Y
- 4. Instrumentation C
NA 3
1 E
mig Y
Y and control
- 5. Distribution panels C
NA NNS II E
mfg N
N I
AC SYSTEM - 13.8 kV i
- 1. 13.0-kV buses and C
NA NNS 11 E
mig N
N switchgear l
NA 3
I E
rnig Y
Y breakers STRUCTURES AND BUILDINGS
- 1. Containment building B
B 2
I MC ASME III, Y
Y
- 2. Equipment hatch B
B 2
I MC 111 Y
Y i
and persennel locks
- 3. Penetration 8
8 2
1 MC 111 Y
Y siteves assemblies a
WAPWR-5/E AMENDMENT 1 l
MAY, 1986 4858e:Id
\\
p TABLE 3.2-1 (Sheet 36 of 41)
CLASSIFICATION OF STRUCTURES. COMPONENTS. AND SYSTEMS (a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(1)
Principal Principal System Quality Safety Seismic Code Construction Safety and Components.
Location Group Class Category Classification Code & Stds.
0-List Related Cosaments i
- 4. Fuel transfer C
8 2
I MC III Y
Y y
tube housing and bellows assembly
- 5. Reactor external C
NA 3
I C
AISC Y
Y building ACI 318
- 6. Diesel geserator K
NA 3
I C
AISC Y
Y area building ACI 318
- 7. Fuel handling F
NA 3
I C
AISC Y
Y area ACI 318
- 8. Control complex G
NA 3
I C
AISC Y
Y area ACI 318
- 9. Diesel fuel oil 0
NA 3
I C
API-650 Y
Y storage tanks
- 10. Spent fuel pool F
NA 3
I C
AISC Y
Y and refueling canal ACI 318 11ner plate
- 11. Containment 8
NA 3
I C
AISC Y
Y internal ACI 318
{
structures ACl349 III-NF
- 10. Electrical cable V8 NA 3
I C
AISC Y
Y trays and supports
- 13. Pipe supports V8 NA 3
I C
AISC Y
Y See Note 5
- 14. Pipe whlp restraints V8 NA 3
I C
AISC Y
Y See Note S WAPWR-S/E AMENoNENT 1 4858e:1d NAY,1986
o o
o o
o o
TABLE 3.2-1 (Sheet 36 of 41) i CLASSIFICATION OF STRUCitNtES. COMPONENTS. AND SYSTEMS (a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(1)
Principal Principal System Quality Safety Seismic Code construction Safety and Coseonents location Group Class _
Category Classification Code & Stds.
0-list Related C_omments
- 4. Fuel transfer C
8 2
I NC III Y
Y y
tube housing and bellows assembly S. Reactor external C
NA 3
I C
AISC Y
Y building ACI 318
- 6. Diesel generator K
NA 3
I C
AISC Y
Y area building ACI 318
- 7. Fuel handling F
NA 3
I C
AISC Y
Y area ACI 318
- 8. Control complex G
NA 3
I C
AISC Y
Y area ACI 318
- g. Diesel fuel oil 0
NA 3
I C
API-650 Y
Y storage tanks
- 10. Spent fuel pool F
NA 3
I C
AISC Y
Y
]
and refueling canal ACI 318 liner plate
- 11. Containment 8
NA 3
I C
AISC Y
Y internal ACI 318 structures ACl349 l
III-NF
- 12. Electrical cable V8 NA 3
I C
AISC Y
Y trays and supports
- 13. Pipe supports V8 NA 3
I C
AISC Y
Y See Note $
- 14. Pipe whip restraints V8 NA 3
1 C
AISC Y
Y See Note S 1
WAPWR-5/E AMENonENT 1 4858e:1d MAY, 1986 i
TABLE 3.2-1 (Sheet 37 of 41)
CLASSIFICATION OF STRUCTURES. COMPONENTS. AND SYSTEMS (a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(1)
Principal Principal System Quality Safety Seismic Code Construction Safety and Components Location
. Group Class Category Classification Code & Stds.
0-tist Related Comments FUEL HANDLING SYSTEN
- 1. New and spent fuel F
D NNS I
C mfg N
N 1
storage racks
- 2. Refueling machine B
NA NNS C
afg N
N
- 3. RCC storage B
NA NNS 11 C
mfg N
N station
- 4. Thimble plug B
NA NNS Il C
mfg N
N storage rack
- 5. Integrated head B
NA NNS 11 C
mfg N
N cable assembly
- 6. Integrated head B
NA NNS 11 C
mig N
N cable tray l
- 1. Integrated head B
D NNS 11 C
afg N
N y
11fting rig B. Integrated head B
C 3
I NF lil-NF Y
Y missile shield I
- g. Reactor internals B
NA NNS 11 C
mfg N
N lifting rig
- 10. Fuel handling P
0 NNS C
afg N
N machine 1
- 11. Spent fuel F
D NNS 11 C
mfg N
N handling tool
- 12. New fuel handling F
NA NNS 11 C
mig N
N l
tool
- 13. Fuel transfer tube F
B 2
I NC III Y
Y
- 14. Fuel transfer system F D
NNS 11 C
mig N
N WAPWR-S/E ANENDNENT 1 4858e:1d NAY,1986
l TABLE 3.2-1 (Sheet 38 of 41)
CLASSIFICATION OF STRUCTURES, COMPONENTS, AND SYSTEMS FOOTNOTES AND COMMENTS a.
Location O
A Reactor Building (B,C)*
B Containment
- C Reactor External Building (F,G,H,1,J,K)*
F Fuel Handling Area
- G Control Complex Area
- H Main Steam Tunnel
- I Essential Safety Facility Area
- J Auxiliary Equipment Area
- K Diesel Generator Area or Building
- 0 Waste Disposal building N
Transformer Area P
Switch Yard T
Turbine Building VB Various Buildings 0
Outside Nuclear Power Block b.
Quality Group The quality group classification corresponds to those provided in Regulatory Guide 1.26.
NA indicates not applicable and is used for equipment and structures that do not fall under the purview of Regulatory Guide 1.26.
O i
O WAPWR-S/E AMEN 0 MENT 1 IB58e:ld MAY, 1986 i
I
2
)
TABLE 3.2-1 (Sheet 39 of 41)
CLASSIFICATION OF STRUCTURES, COMPONENTS, AND SYSTEMS c.
Safety Class The nuclear safety class corresponds to the quality group classifications in ANSI /ANS-51.1-1983, Nuclear Saf ety Classes 1, 2, 3, and NNS.
d.
Seismic Category Seismic Category I is applied to those safety-related structures, systems, and components that must remain functional during and after a safe shutdown earthquake (SSE) according to Regulatory Guide 1.29 and to those nonsafety-related structures, systems, and components that are designed to Seismic Category I requirements.
e.
Code, Classification See Subsection 3.2.2.3.
O f.
Principal Construction Code 4
The codes referenced are primary codes only and are defined in Table 3.2-2.
Detailed construction codes are listed in the component specification.
g.
Q-List Y
Yes; requires compliance with 10 CFR 50, Appendix B, as implemented in the MAPWR quality assurance programs.
N No; not within the scope of 10 CFR 50 Appendix B.
O i
O AMEN 0 MENT 1 WAPWR-S/E 4858e:1d MAY,1986 l
l
s a TABLE 3.2-1 (Sheet 40 of 41)
CLASSIFICA110N OF STRUCTURES, COMPONENTS, AND SYSTEMS h.
Safety Related Y
Yes; safety related.
N No; not safety related.
l 1.
Comments This column contains a listing of applicable design criteria and other amplifying information.
J.
The main control board will be qualified by Westinghouse to Institute of Electrical and Electronics Engineers (IEEE) 344 and 323.
k.
Post-accident monitoring system (PAMS) instruments are assigned a
classification based on their category as defined in Regulatory Guide 1.97, Revision 2.
O 1.
Selected materials, components,
- parts, appurtenances, and piping subassemblies are procured in accordance with ASME Code,Section III, Class 3; however, the system is designed and installed in accordance with ANSI B31.1.
Conformance with these aspects of the ASME code is required only for initial procurement.
n.
The entire heat exchanger is constructed to ASME Section III requirements to ensure the integrity of the safety-related portion.
O o.
Portions of the sample system that are part of the pressure boundary of the system being sampled must meet the same quality and code requirements as that sampled system up to and including the first normally shut isolation valve in the sample line.
O WAPWR-S/E AMENDMENT 1 4858e:ld MAY,1986
i TABLE 3.2-1 (Sheet 41 of 41)
CLASSIFICATION OF STRUCTURES, COMPONENTS, AND SYSTEMS p.
The quality assurance program to be applied to fire protection systems is described in Branch Technical Position APCSB 9.5-1 Appendix A, attached to Nuclear Regulatory Consnission (NRC) Standard Review Plan 9.5.1.
q.
The quality assurance program to be applied to radioactive waste management systems is described in Regulatory Guide 1.143.
r.
Heat tracing and associated heat tracing equipment for the safety O
injection system is redundant, procured as Class 1E, and seismically and environmentally qualified in accordance with IEEE 323, 344, and 383.
s.
Safety related supports and hangers are to be classified corresponding to the function provided by the supported equipment unless failure of the support would not jeopardize the function of the equipment.
As appropriate, Subsection NF of Section III of the Code is to be utilized.
O O
O O
WAPWR-S/E AMENDMENT 1 4858e:1d MAY,1986
l 4 8 W f
TABLE 3.2-2 (Sheet 1 of 3)
O PRINCIPAL CODES AND STANDARDS l
I ASME Boiler and Pressure Vessel Code, Section 1.
111-1,2,3, MC, NF, ASME Boiler and Pressure Vessel Code,Section III, 1
CS, NG Class 1, 2, 3 or MC, NF, NG, or CS.
VIII ASME Boiler and Pressure Vessel Code,Section VIII, Division 1.
B31.1 ANSI B31.1.0, Power Piping.
AISC American Institute of Steel Construction.
AISI American Iron and Steel Institute, Specification for O
the Design of Cold-Forined Steel Structural Members, 1968 Design of Light 6 age Cold-Formed Stainless Steel i
Structural Members.
AMCA Air Moving and Conditioning Association.
ACI 318 American Concrete Institute, Building Code l
Requirements for Reinforced Concrete.
ACI-349 American Concrete Institute, Code Requirements for Nuclear Safety Related Structures.
ANSI N509 American National Standard Institute, Nuclear Power Plant Air Cleaning Units and Components, 1976.
API-620 American Petroleum Institute, Recomended Rules for l
Design and Construction of Large, Low Pressure Storage Tanks.
WAPWR-S/E AMENDMENT 1 4858e:ld MAY,1986
\\