Environ Assessment & Finding of No Significant Impact Re Exemption from 10CFR50,App J,Paragraph III.A.3, Primary Reactor Containment Leakage Testing for Water-Cooled Power Reactors
ML20154R866
Person / Time
Site: Monticello Xcel Energy icon.png
Issue date: 09/23/1988
From: Diianni D
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20154R856 List:
References
NUDOCS 8810040376
Download: ML20154R866 (4)


Text

...

0 7590-01 UNITED STATES NUCLEAR REGULATORY COMMISSION NORTHERN STATES POWER COMPANY MONTICELLO NUCLEAR GENERATING PLANT DOCKET NO. 50-263 ENVIRONMENTAL ASSESSMENT AND FINDING OF NO SIGNIFICANT IMPACT The U. S. Nuclear Regulatory Commission (the Commission) is considering issuance of an exemption from the requirements of Appendix J to 10 CFR Part 50 to Northern States Power Company (the licensee) for the Monticello Nuclear Generating Plant, located in Wright County, Minnesota.

EhVIRONMENTAL ASSESSMENT 1

Identification of Proposed Action:

The licensee requested an exemption from Paragraph III.A.3 of 10 CFR Part 50, Appendix J, "Primary Reactor Containment Leakage Testing for Water-Cooled Power Reactors."

In 1973, Appendix J was issued to establish requirements for l

primary containment leakage testing and incorporated, by reference, ANSI N45.4-1972, "Leakage Rate Testing of Containment Structures for Nuclear Reactors."

This standard requires that containment leakage calculations be performed by using J

either the Point-to-Point method or the Total Time method. The Total Tire method was used the most by the nuclear industry until about 1976.

i At this time, licensees who wish to use the Mass-Point method of calculating containment integrated leakage must submit an application for exemption from the Appendix J requirement that containment integrated leak rate tests will conform to ANSI N45.4. The exemption proposed by the licensee would be granted until pending changes to Appendix J are promulgated.

In the Mass-Point method, N$ knob $koN$$$63 P

PDC

the mass of air in containment is calculated and plotted as a function of time, and leakage is calculated from the slope of the linear least squares.

With the present developments in technology, the Mass-Point method has i

gained increr. sing recognition.

The superiority of the Mass-Point method becomes apparent when it is compared with the two other methods.

In the Total Time method, a series of leakage rates are calculated on the basis of air mass differences between an initial data point and each individual data point thereafter.

If for any reason (such as instrument error, lack of temperature equilibrium, ingassing or outgassing) the initial data point is not accurate, the results of the test will be affected.

In the Point-to-Point method, the leak rates are based on the mass difference between each pair of consecutive points which are then j

averaged to yield a single leakage rate estimate. Mathematically, this can be shown to be the difference between the air mass at the beginning of the test and the air mass at the end of the test expressed as percentage of the I

containment air mass.

It follows from the above that the Point-to-Point rethod ignores any mass readings during the test and thus the leakage rate is calculated on the basis of the difference in mass between two measurements taken at the beginning and at the end of the test, which are 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> apart.

i The licensee's request and bases for exemption are contained in a letter dated August 1,1980, as supplemented t,y letter dated August 23, 1986. The exemption would permit the licensee to use the Mass-Point inethod for calculating containment leakage rates as an acceptable alternative to the Point-to-Point and Total Time methods currently specified in Appendix J.

The Ny,4 for the Proposed Action:

The proposed exemption is needed to allow use of the Mass-Point analysis j

l l

.____..__,_._._____._.__._,m

method at Monticello Nuclear Generating Plant and for improved analysis of the test results.

Environmental Impacts of the Proposed Action:

The erraticism of the Total Time method creates a higher probability of 2

unnecessarily failing a containment integrated leakage rate test (note that thecalculationalprocedureisindependentofcontainmenttightness) possibly resulting in increased test frequency, critical path outage time, and exposure to test personnel.

Radiological releases will not be greater than previously determined, nor does the proposed exemption otherwise affect radiological plant effluents, or i

have any other environmental 1:apact. Therefore, the Connission concludes

. hat there are no measurable radiological or nonradiological environmental impacts associated with the proposed exemption.

Alternative to the Propcsed Action:

The Comission has concluded that there is no reasurable impact associated with the proposed exemption; any alternatives to the exemption will have either no environrental impact or greater environtrental impact.

Alternative Use of Pesources:

This action does not involve the use of any resources beyond the scope of resources used during normal plant operation, which have been previously considered by the Coernission in the ?inal Environmental Statement dated Noverber 1972.

Agencies and Persons Consulted:

The Conc.ission's staff reviewed the licensee's request that supports the proposed exemption. lne staff did not ensult other agencias or persons.

~_

4 FINDING OF NO SIGNIFICANT IMPACT Based upon the foregoing environmental assessment, the Comission concludes that the proposed action will not have a significant effect on the i

quality of the human environment. Accordingly, the Comission has determined not to prepare an environmental impact statement for the proposed exemption.

For further details with respect to this action, see the request for the exemption dated August 1,1988, as supplemented by letter dated August 23, r

t 1988, which is available for public inspection at the Comission's Public Document Room, 1717 H Street, NW., Washington, DC, and at the Minneapolis Public Library, Technology and Science Department, 300 Nicollet Mall, Minneapolis, Minnesota 55401.

Dated at Rockville, Paryland, this 23rd day of Septenber 1988.