Northem States Power Company Monticello Nuclear oeneratng Plant 2007 West Hwy 75 Monticello, Minnesota 55362-9637 February 16,1998 US Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 MONTICELLO NUCLEAR GENERAT!NG PLANT Docket No. 50-263 License No. DPR-22 Submittal of Annual Occupational Exposure Report in Accordance With MNGP Technical Specification 6.7.A.2 l

The subject report is attached. Please contact Joel Beres, Monticello Licensing, at (612) 295-1436 if additionalinformation is required.

(4 TOV Michael F. Hammer Plant Manager Monticello Nuclear Generating Plant c: Regional Administrator-111, NRC NRR Project Manager, NRC Sr. Resident Inspector, NRC j$

State of Minnesota, Attn: Kris Sanda \

J. Silberg, Esq.

Attachment:

Number of Personnel and Man-Rem by Work and Job Functions (1997)

Monticello Nuclear Generating Plant #

4 9802250131 971231 t i PDR ADOCK 05000263 R PDR 2t1698 J 11 CENSE \JOELLETTER$111MANREM DCC

. . I l.li!.I.l .l

.i.l'i!!!!

o

PMETS' Number of Personnel and Man-Rem Page 1 02/11/98 '

by Work and Job Functions (1997) of 2 Monticello Nuclear Generating Plant Munber of Persons > .100 Rem Total Man-Rem Work and Job Function Station Utility Contract Station Utility Contract ISI Operators 0 0 0 0.000 0.000 0.000 Maintenance 0 0 10 0.000 0.057 2.234 Supy & Engr 0 0 2 0.002 0.019 0.350 Health Physics 0 0 0 0.009 0.000 0.011 Instr & Control 0 0 0 0.000 0.000 0.000 Security 0 0 0 0.000 0.000 0.000 Routine Maintenance Operators 0 0 0 0.338 0.000 0.000 Maintenance 26 3 25 6.894 1.672 7.604 Supv & Engr 17 0 2 4.171 0.199 0.638 Health Physics 8 1 1 2.355 0.236 0.582 Instr & Control 4 0 0 0.729 0.000 0.000 Security 0 0 0 0.000 0.000 0.000 Operations Operators 29 0 0 10.921 0.000 0.000 Maintenance 23 2 23 5.266 0.677 6.439 Supv & Engr 12 0 2 3.610 0.150 0.726 Health Physics 23 1 1 7.089 0.235 0.335 Instr & Control 7 0 0 2.370 0.000 0.000 Security 0 0 0 0.000 0.000 0.023 l

Refueling Operators 0 0 0 0.000 0.000 0.000 Maintenance 0 0 0 0.000 0.000 0.000 Supv & Engr 0 0 0 0.000 0.000 0.000 Health Phyoics 0 0 0 0.000 0.000 0.000 Instr & Control 0 0 0 0.000 0.000 0.000 Security 0 0 0 0.000 0.000 0.000 Special Maintenance Operators 0 0 0 0.269 0.000 0.000 Maintenance 0 19 85 0.066 4.744 30.322 Supv & Engt 3 3 4 1.018 0.968 1.053 Health Physics 2 0 1 0.605 0.000 0.267 Instr & Control 0 0 0 0.000 0.000 0.000 Security 0 0 0 0.000 0.000 0.000 ER_41 PME_97335T Database Pmets_ static (last updated 02/04/98 03:35 )

~1

PMETS* Number of Personnel and Man-Rem Page 2 02/11/98, by Work and Job Functions (1997) of 2 .

Monticello Nuclear Generating Plant Number of Persons > .100 Rem Total Man-Rem Work and Job Function Station Utility Contract Station Ut .ity Contract Waste Shipping /Handl Operators 3 0 0 0.000 0.000 0.000 Ma4.ntenance 0 0 0 0.143 0.000 0.040 Surv & Engr 0 0 0 0.001 0.000 0.000 Health Physics 0 0 0 0.009 0.000 0.011 Instr & Control 0 0 0 0.000 0.000 0.000 Security 0 0 0 0.000 0.000 0.000 Unassigned Exposure -0.158 -0.004 0.683 Sub Totals Operators 25 0 0 11.528 0.000 0.000 Maintenance 49 24 143 12.369 7.150 46.639 Supv & Engr 32 3 10 8.802 1.336 2.767 Health Physics 33 2 3 10.127 0.471 1.206 Instr & Control 11 0 0 3.099 0.000 0.000 Security 0 0 0 0.000 0.000 0.023 Unassigned -0.158 -0.004 0.633 Grand Totals 154 29 156 45.767 8.953 51.318

    • INDIVIDUALS MAY BE LISTED UNDER MORE THAN ONE WORK AND JOB FUNCTION Monticello took an unscheduled voluntary shutdown to replace ECCS suction strainers in the torus. Dose for this outage was 71.675 Rem Special Maintenance includes:
1. ECCS suction strainer replacement in the torus.
2. Repair of the Drywell floor to Drywell shell interface.

ER_41 PME_97335T Database Pmecs_ static (last updated 02/04/98 03:35 )