Text
_
- p__
- - mm - =7ugmm m m mm mm m m m m m m m m mm mm-m m m mmm g l
NEC Form 374 i
PACE y
2 g
g ts.84)
$.S. NUCt. EAR REGULATORY COMMISSION OF PAGES l
MATERIALS LICENSE Amendment No. 03 Pursuant to the Atomic Energy Act of 1954, as amended, the Energy Reorganization Act of 1974 (Public Law 93-438), and Title 10, g
Code of Federal Regulations, Chapter 1, Parts 30,31,32,33,34,35,40 and 70, and in reliance on statements and representations g
g heretofore made by the licensee, a license is hereby issued authorizing the licensee to receive, acquire, possess, and transfer byproduct, g
(
source, and special nuclear material designated below; to use such material for the purpose (s) and at the place (s) designated below; to l
deliver or transfer such material to persons authorized to receive it in accordance with the regulations of the applicable Part(s). This
&j' license shall be deemed to contain the conditions specified in Section 183 of the Atomic Energy Act of 1954, as amended, and is N
subject to all applicable rules, regulations and orders of the Nuclear Regulatory Commission now or hereafter in effect and to any j conditions specified below.
I Licensee i
In accordance with letter dated May 2, 1985 and letter received January 2, 1986, I-
- 3. License number SNM-1531 is amended in its Shadyside Hospital entirety to read as follows:
l 2
(
5230 Centre Avenue 4
Pittsburgh, Pennsylvania 15232
- 4. Expiration date January 31, 1991 l
- 5. Docket or l
Reference No.
070-01/18
[
- 6. Byproduct, source, and/or
- 7. Chemical and/or physical
- 8. Maximum amount that licensee g
- may possess at any one time i
'b under this license A. Plutonium (Principal A. Sealed source (s)
A. 10 grams (20 individual
!~
lN radionuclide Pu-238) sources not to exceed 3
500 milligrams each) id
!N 9.
Authorized use i
! A.
Implantation in humans as a component of ARC 0 Nuclear Model NU-5 nuclear-powered l
l cardiac pacemakers for clinical evaluation purposes.
l l
lEl CONDITIONS t
i 10. Licensed material shall be used only at 5230 Centre Avenue, Pittsburgh, Pennsylvania.
p 11. The specified possession limit includes all licensed material possessed by the g
licensee under this license whether in storage, implanted in patients or otherwise p
in use, g
E 12.
The 'icensee shall not receive or transfer in any single transaction one (1) gram or more of plutonium 238 contained in nuclear-powered pacemakers without notifying the Division of Safeguards, U. S. Nuclear Regulatory Commission, Washington, D. C. 20555, i q
and, in addition, completing and distributing Form NRC-741 as required by Section 70.54 of 10 CFR 70.
N d 13. The licensee shall report to the U. S. Nuclear Regulatory Commission, Region I, i
l Nuclear Materials Section, 631 Park Avenue, King of Prussia, Pennsylvania 19406, y
within twenty-four (24) hours of occurrence, the death of any nuclear pacemaker g
patient, and any adverse reaction and/or malfunction involving a pacemaker system, N
including the leads. A written report giving details of the adverse reaction and/or p
H malfunction shall be submitted within thirty (30) days.
p H
l
- 14. The licensee shall report to the U. S. Nuclear Regulatory Commission, Region I, N
y Nuclear Materials Section, 631 Park Avenue, King of Prussia, Pennsylvania
- 19406, h
q within ten (10) days, loss of contact with a nuclear pacemaker patient.
f W rp m m,
'}$.3 8
0603210170 e60213 J.i.. h c-I I N
g1y70 gsp--msm----mmmmmmmmm mmm-mmmm--- d
,l-. -- -- ------- Emammmmmmmzwenes:wwarwarzwawr wmg g ARC Form 374A U.S. NV 1AR REGULATORY COMMISSION
[}p p
p p
g 6
- U License numbe#
l MATERIALS LICENSE nocket or itererence n i
SUPPLEMENTARY SHEET h
070-01738 p
/
F AmendmenLNoJ3 E
h (Continued)
CONDITIONS
- 15. The licensee shall continue patient follow-up and replacement procedures for the nuclear pacemaker during the life of the patient.
Procedures for recovery and j
authorized disposal of the nuclear pacemaker bv return to the manufacturer shall i
be followed upon the death of the patient.
16.
Except as specifically provided otherwise by this license, the licensee shall possess and use licensed material described in Items 6, 7, and 8 of this license in accordance with statements, representations, and procedures contained in letter with enclosures dated April 25, 1975; letter dated May 2,1985 and letter received January 2,1986.
1 The Nuclear Regulatory Commission's regulations shall govern the licensee's statements 9
in applications or letters, unless the statements are more restrictive than the regulations.
91 91 D
1%
Ii i
i 3
r>
St k
!k p=
t k
ti%
s Mil,1 ii o;
For the U.S. Nuclear Regulatory Commission p
FEB 121986 UWad No'7-hl i;Date By Jo M. M m an pj Nuclear Materials Safety and P
i Safeguards Branch, Region I King of Prussia, Pennsylvania 19406 p
- - - -