Text

n

~

y

,

.

-.

!.

y ~ -.

'

!

-

,

.

June 29, 1988

Docket Nos. 50-325, 50-324

License Nos. DPR-71, DPR-62

Carolina Power and Light Company

ATTN: Mr. E. E. Utley

Senior Executive Vice President

Power Supply and Engineering

and Construction

P. O. Box 1551

'

Raleigh, NC 27602

Gentlemen:

SUBJECT: NOTICE OF VIOLATION

(INSPECTION REPORT N05. 50-325/88-18 AND 50-324/88-18)

This refers to the Nuclear Regulatory Commission (NRC) inspection conducted by

William H. Ruland on May 1 - June 4, 1988.

The inspection included a review of

'

activities authorized for your Brunswick facility ^.

At the-conclusion of.the

inspection, the findings were discussed with those members of your staff

identified in the enclosed inspection report.

Areas examined during the inspection are identified in the report.

Within

these areas, the inspection consisted of selective examinations of procedures

'

and representative records, interviews with personnel, and observation of

i

activities in progress.

J

The inspection findings indicate that certain activities appeared to violate

.

NRC requirements.

One violation (325/88-18-01), references to pertinent

requirements, and elements to be included in your response are described in

'

the enclosed Notice of Violation.

In addition, three other violations

(324/88-18-03, 324/88-18-04, and 325,324/88-18-05) were identified.

These

violations are described in the enclosed Inspection Report and are under

consideration for escalated enforcement action.

Accordingly, no Notice of

Violation is being issued at this time, and no response to those particular

j

violations is required.

However, _ please be advised that the number and

'

,

characterization of violations described herein may change as a result of

further NRC review.

The first two of these violations were discussed during a

May 27, 1988 Enforcement Conference.

An Enforcement Conference to discuss the

third violation has been scheduled for July 7,1988.

You will be advised by

separate correspondence of the results of our deliberations on this matter.

'

Also, in one instance, because all of the criteria for categorization of

licensee-identified violations were met, the violation is not being cited.

i

The details pertaining to the licensee-identified violation are described in

paragraph 6.a of the enclosed Inspection Report.

8807190299 880629

l

PDR

ADOCK 05000324

)\\

'

O

PDC

4

.[EM

.

.

, _ . _ _ . . . . .

_

.

. -

.

. -

- - - -

.

.

% _, . - '

.

.

Carolina. Power and Light Company

2

June 29, 1988

'

Your attention is called to -the unresolved items identified in the inspection

.repor .

These matters will be pursued during future inspections.

t

In accordance with Section 2.790 of the NRC's "Rules of Practice," Part 2,

Title 10, Code of Federal Regulations, a copy of this letter and its enclosures

will be placed in the NRC Fublic Document Room.

The responses directed by this letter and its enclosures are not subject to the

clearance procedures of the Office of Management and Budget as required by the

Paperwork Reduction Act of 1980, PL 96-511.

Should you have any questions concerning this letter, please contact us.

Sincerely,

Original Signed by

Luis A. Reyes /for

J. Nelson Grace

Regional Administrator

1

Enclosures:

1.

Notice of violation

2.

NRC Inspection Report

3.

U-2 Heatup SOE

cc w/encis:

P. W. Howe, Vice President

Brunswick Nuclear Project

C. R. Dietz, Plant General Manager