Discusses Error in Part 20 That Can Be Corrected in Forthcoming Set of Minor Clarifying Changes
ML20149K254
Person / Time
Issue date: 08/11/1993
From: James Buchanan
NRC
To: Roecklein A
NRC
Shared Package
ML20149C780 List:
References
FRN-61FR52388, RULE-PR-20, RULE-PR-32, RULE-PR-35, RULE-PR-36, RULE-PR-39 AF46-1-004, AF46-1-4, NUDOCS 9707300088
Download: ML20149K254 (2)


Text

.-. ~.

AP-46-A I

PDR 1

From:

John D. Buchanan (JDB2)

To:

JXD1, AKR Date:

Wednesday, August 11, 1993 10:03 am l

Subject:

Part 20 fix needed Jack Bell noticed another error in Part 20 that can be corrected in the forthcoming set of minor clarifying changes.

See the j

attached file for details.

Please let me know if you see any problem with including this change.

l CC:

JMB2, JEW 2, LJC2 Files:

P20FIX.#34 l

i J

t

\\

lb i

d i

i

[

t

{

f V

i t

i 1

l 1

9707300088 970711 PDR PR

-. ~ ' '

20 61FR52388 PDH 97D1306&SW

s.

"d.

O s

i

/

Y I

34.

10 CFR 20.1703 (b) (1), second sentence:

Add the words

" multiple defined in the preceding sentence" and delete the words

" peak concentration." so that the sentence reads as follows:

"If the selection of a respiratory protection device with a protectio l

factor greater than the multiple defined in the preceding sentenc is inconsistent with the goal specified in 20.1702 of keeping th 4

total effective dose ALARA, the licensee may select respiratory protection equipment with a lower protection factor only if such selection would result in keeping the total effective dose equivalent ALARA."

I l

The current wording is incorrect in referring to a protection i

factor (which has no units) that is greater than a peak j

concentration (which has units of activity per unit volume).

The i

revised wording is consistent with the intended meaning of this t