14 pages EFFLUENT AND WASTE DISPOSAL SEMI ANNUAL REPORT July 1, 1987 to December 31, 1987

' SUPPLEMENTAL INPORMATION FACILITY TMt m4 q (ine'udinn r iene. f f ) LICENSEE npp.71 Qq n

1.

Regulatory Limits a.

Pission and activation gases:

En ona c.

c stes, half-lives > 8 days:

gc 3

d.

Liquid effluents:

2.

Maximum Permissible Concentrations Provide the MPCs used in determining allowable release rates or cencentrations.

a.

Pission and activation gases c.

r e ates, half-lives 8 days O m Part 20, Appendix B d.

Liquid effluents:

3.

Average Energy Provide the average energy (E) of the radionuclide mixture in releases of fission and activation gases, if applicable 0.253 Ney (Kr-85) 4 Measurecents and Approximations of Total Radioactivity Provide the methods used to measure or approximate the total radioactivity in effluents and the methods used to determine radionuclide composition.

a.

Pissi/n and activation gases:

Ge (L1) Spectrometry Liquid Scintillation b.

Iodines:

Ge (Li Spectrometry c.

Particulates:

Ge (Li Spectrometry, Gas Flow Proportional d.

Liquid effluents:

Ge (Li Spectrometry, Liquid Scintillation 5.

Batch Releases Provide the following information relating to batch releases of radioactive materials in liquid and gaseous effluents.

1987 1987 A.

Liquid 3rd Quarter 4th Quarter 1.

Number of batch releases:

60 29 2.

Total ti=e period for batch release:

h/A fi/A 3.

Max 1=um time period for a batch release:

N/A N/A 4

Average time period for batch releases:

N/A N/A 5.

Minimum time period for a batch release:

N/A N/A 6.

Average stream flow during periods of release of effluent into flowing stream:

N/A N/A See Note (1) and

  • on Page 6 of this report.

N/A = not applicable 8803040024 880229 PDR ADOCK 05000320 R

DCD

,g_

c........

o.

c 5.

Batch Releases (cont.)

1987 1987 3.

Gaseous 3rd Quarter 4th Quarter 1.

Number of batch releases:

0 0

2.

Total time period for batch releases:

N/A N/A 3.

Maximum time period for a batch release:

N/A-N/A 4.

Average time period for batch release:

N/A N/A 5.

Minimum time period for a batch release N/A N/A 6.

Abnormal Releases A.'

Liquid 1.

Number of releases:

None None 2.

Total activity released:

N/A N/A 3.

Caseous 1.

Number of releases:

None None 2.

Total activity released:

N/A N/A e

h l

r i

l l

> J

,[

I' TABLE 1A EFTLU ST AND WASTE DISPOSAL SEMIANNUAL REPORT GASEOUS EFFLUENTS-SUMMATION OF ALL RELEASES i

UNIT 3rd...

4th.

EST. TOTAL

~~~

~

QUARTER QUARTER ERROR, %

1987 1987

!.. Fission & activation gases

1. Total release ci

<ll D

<lLO 1 60"

2. Average release rate for period uCi/sec.

N/A N/A Tech. Spec. Limit =

3. Percent of Tech Spec limit N/A N/A h2r Kr 5 I*

Iodines e

i

_1. Total Iodine-131 Ci

<LLD

<llD 160"

2. Average release rate for period uti/sec.

N/A N/A Tech. Spec. Limit =

l 1

~~-

2.40 E-2 uCi/see i

3. Percent of Tech Spec limit N/A N/A C.

Particulates

1. Particulates with half-lives

> a n s..,

C1 4.31E-6 1.11E-5

+ 6 i> e..

k 2_. Averaee release rate for period uCi/sec.

5.04E-7 1.40E-6 Tech. Spec. Limit =

3. Percent of Tech Spec limit

?.0?r-3 5.83E-3

4. Cross alpha radioactivity Ci 4.40E-8 6.08E-8 D.

Tritiuza

_1. Total release ci 7.00E0

?.05r0 60;;

2. Average release rate for peried uti/sec.

8.81E-1 3.71E-1 Tech. Spec. Limit =

3. Percent of Tech Spec 11=1t 4.80E+3 uCi/sec 1.84F-?

7.71r-1 for H-3 l

l 1._ - __- -

~-

TABLE IB EFFLUENT AND WASTE VISPOSAL SEMIANNUAL REPORT GASEQUS EFFLUENTS-GRCLI:D IDE RELEASE Continuous Mode Batch Mode Nuclides tyt7 Ig7 1j8]

1 87 lg8 Released QUARTER QUARTER QLAKTER QL TER 1.

Fission gases krypton-85 Ci

<LLD

<tLD

<tLD

<! ! n l'

krypton-85m Ci

<tLD

<tLD

<tLD

<LLD krypton-87 Ci

<t I n et i n

<t ! n

<!'n kryp ton-88 Ci

<tLD

<LLD

<LLD

<tLD xenon-133 Ci et ? D

<t i D

<f t n

<f I n xenon-135 Ci

<LLD

<LLD

<LLD

<tLD l

xenon-135m Ci etLO

,LLD

<LLD

<LLD l

xenon-138 Ci

<tLD

<lt D

<tt D

<t I D Others (specify)

Ci

<tLD

< t! D

< t! D

<tLD ci i

C1 C1 Ci ll Unidentified Ci

<ttD

< tL D

<tLD

< lLD Total for period Ci N/A N/A N/A N/A 2.

Iodines iodine-131 Ci

< tin

<lt D

,3

.r ia iodine-133 ci

< LLD

<lt D

+1/ A N/A iodine-135 Ci

< LLD

<t t 0 U/A N/A Total for certed Ci N/A N/A N/A N/A _ _ _ _ _ _ _ _ - _ _ _ _ _

c e...=

i s

t TABLE 13 (cont.)

0FTLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT CASEOUS EFFLUENTS-CROUND LEVEL RELEASES i

i i

Continuous Mode

  • Nuclides Batch Mode i

Released UNIT lj87 18 g

lj87 lj,[

8 QUARTER Q

TER QUMTER QUARTIR i

3.

Particulates s

strontium-89 Ci

<ll D

<t L D N/A N/A strontium-90 Ci

' ! n g r.. ?

ain

fA cesium-134 Ci 1/A

<!! D 1 17r.7 yfa cesium-137

{

Ci

.; f a 7 nr.7 7 air.g yfa yfg

(

barium-lanthanum-140 Ci

<L t. D

<lLD N/A N/A I

Others (specify)

~ '~

I n,

-i Unidentified

.s 3.37E-6 3.56E-6 N/A N/A b

t f

i f

,I l

i 3

l

.c y,

TABLE 2A EFFLUENT AND WASTE DISPOSAL SEMI. ANNUAL REPORT LIQUID EFFLUENTS-SUMMATION OF ALL RELEASES

[

] 987 EST. TOTAL UNIT QUARTER Q[A(TER ERROR % -

A.

Fission and activation products

1. Total releases (not including tritium 5:ases, alpha)

C1 3.02E-5

? 1nr_ L..-+ 60%

2. Ave se d ea concentration uCi/mi 2.40E-12 2.28E-12 Based on 2E-5.
3. Percent of applicable limit-uCi/mi (Cs-137) 1.20E-5 1.1dF 4 B.

Tritium-

1. Total release

~

~~"

~ Cl ~

'8.55E-4 2.65E-4 1 60%'

z. Average.ciluteo concentrataan during period UC1/ml 6.79E-11 2.62E-11 Based on 3E-3
3. Percent of applicable limit-' -

~

^

2.26E-6 8.73E-7 C.

Dissolved and entrained gases ~

~

~ ' ' '

l. Total release Ci
4. Average dilutea conceatration N/A N/A t 60%

durine eeriod UC1/mi N/A N/A

3. Percent of applicable limit N/A N/A D.

Gross alpha radf.oactivity-

's

1. Total release a

Ci Note (1)

Note (1) i 25%

E. Volume of waste releaseo (prior to dilution) liters 1.68E5 9.23E4 1 25%

F. Volu=e of dilution water used durinc eariod liters 1.26E10 1.01E10

+ 10%

includes only those releases rnentioned in Note (1) whiCh were found to Contain rJdloisotope

)

con. Centration >lLO.

{

Plote (1) there were no lighid releases frcrn the radwdste [ystem during the seCond half of 1987 sine,e !

this *,yst(m is. flanged of f. front the discharge lines,

' * + ' - -

llowever. low Concentrations of radionuclides have been occasionally found in the industrI41 waste stream and are tuoropriately included in lton A2.

40te (2)

Wer to table 5 for typical LLO values.

' ente (3) th* v41ues recorted include Sr.10 activity and any activity not soecitically identit'ied Ihus. the reported

',r.0 value represents a conservative estimte (i.e. overesticate) ano l

Contatn'..ittivity trrri other Deta.*1atTu **lliters untCh were not positively identified d

' OntluC t

.t anal,t:tii ;rocedures, uring l

- -, -, ~

.-m

.w-.,,.-.--._,-,-%,,--,..e,,

.o.wy..,.

,,.v.wme,-c__-,m,,,,,-es-+--,-,---,ww,,-,w-,,,,

.g,

'r TABLE 2B EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT LIQUID EFFLUEiTS Continuous Mode Batch Mode Ij8}

1l8{

lj8f 1g8{

Nuclides UNIT Released QUARTER QUARTER QUARTER QUARTER strontium-89 dee note 4 dee isote 4 Ci p.7n g p 3,, o g

<f!n

< t LD strontium-90 Note 3 p=ce6 C1 1_ A 7t_5 1.70E-5 cesium-134 Ci

<ien

<ttn, casium-137 Ci 1.16E-5 6.07E-6 fodine-131

.r4

< LLD

< llD cobalt-58 Ci

~

't!D

<t'D cobalt-60 Ci

< LLO

< Ltc iron-59 Ci

< Ltc

< llD

_ eine-65 Ci

< !i n

< ;i n man a ean e se-54 C1

< i.l0

< l'_ D chromium-51 Ci

< !I D

<UD zirconium-niobium-95 Ci

< LLD

< LLD

=o3ybdenu=-99 Ci

< LLD

< LLD technecium-99c Ci

, llD e llD

_ barium-lanthanum-140 Ci

< LLD

< llD cerium-141 Ci

< LLD

< LLD Other (specifv)

C1 C1 Ci Ci C1 Ci N

Unidentified Ci

< llD

< llD Total for ceriod Ci 3.02E-5 2.30E-5 xenon-133 Ci

< 110 e llD xenon-135 Ci

< llD

< LLD

_7

.b EPICOR LINERS July 1, 1987 throuch December 31, 1987 TABLE 3A EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT SOLID WASTE AND IRRADIATED FUEL SHIP.T3TS A.

Solid waste shipped off-site for burial or disposal (not irradiated fuel)

1. Type of waste UNIT f,%h ES TQTAL
a. Spent resins, filter sludges,

m' 102.73 m3 y"

evaporator bottoms, etc.

Ci KO.nb n m i n e-

b. Dry compressible vaste, contaminated n'

ecuiement, etc.

c4 N/A N/A

c. Irractates ce=ponents, control 3

m N/A N/A rod s, etc.

Ci

d. Other (describe)

[g' N/A N/A

2. Estimate of major nuclide cocoesition (bv type of waste) a.

cbl os L7. 3h %

sr o o

17.57v N1 L 7 12.53%

hl.S.1m 12.11%

i e

c.

y

^

d.

3. Solid Waste Disposition Nurber of Shipments Mode of Transportation Destination a.

13 Shirmen+s Tractor-Cask (NuPac 14/190m)

Hanford-Richland. WA a.

4 Shirments Tractor-Cask (liN100 Series 2) Hanford-Richland. WA a.

L Shirments Tractor-Flatbed Hanford-hichland, nA B.

Irradiated Fuel Shipments (Disposition)

Number of Shipments Mode of Transportation Destination N/A

' Shipped in 18 Steel Liners at 161 Ft3 Each k Steel Liners at 170 Ft3 Each 1 Steel Liners at 50 Ft3 Ea ch.

c TMI-2 LSA July 1, 1987 through December 31, 1987 TABLE 3A EFFLUENT AND WASTE DISPOSAL SEMIAh*NUAL REPORT SOLID WASTE AND IRRADIATED FUEL SHIPMENTS Solid waste shipped off-site for burial or disposal (not' irradiated fuel)

A.

1. Type of waste f,*["jh E

TOTAL UNIT

a. 5 pent resins, filter sludges, m'

evaporator bottets, etc.

C' N/A N/A

b. Dry coupressible waste, contaminated m'

160.72 m3 equie.ent, etc.

r4 2.hh7 Curiec 5#

c. Irraciatec co=ponents, control 3

m rods, etc.

Ci N/A N/A ma

d. Othr.r (describe)

N/A N/A Ci

2. Estisate of =ajor nuclide conoosition (bv type of waste) a."/ t T
b. Srgo 58.78(N f 237

?L. 31 t Pelh7 10.68 %

Rul06 3.36 %

Sbl.25 2.189%

c.

t 2

d.

t f

3. Solid Waste Disposition Number of Shipments Mode of Transportation Destination

/

(b) 6 Shir.ments Tractor-Flatbed Han ford Pi chi n ni. WA (b) 1 Shir ent Tractor-Cask (NuPac 1h/10Dn)

Hanford-Richland. WA

((b) 1 Shirment b) 1 Shipment Tractor-Closed Van Hancord_p!-h1 9na y3 k

Tractor-Closed Van

- Barnve11. 90 B.

Irradiated Fuel Shipments (Disposition)

Number of Shipments Mode of Transportation Destination U/A

)

  • Shipped As 52 Steel Boxes e 98 Ft. 3 Each 150 Steel Druns @ 7.5 Ft.3 Each 1 Steel Liner @ 161 Ft.3 Each

-8

b HICs T?JI 2 July 1, 1987 through December 31, 1987 TABLE 3A EFTLUENT AND WASTE DISPOSAL SEMIANNL'AL REPORT SOLID WASTE AND IRRADIATED FUEL SHIP.T3TS A.

Solid waste shipped off-site for burial or disposal (not' irradiated fuel)

1. Type of waste UNIT Nh gTgTAL
a. 5 pent resins, tilter slueges, m*

evaporator bottoms, etc.

Ci N/A N/A

b. Dry co=pressible waste, contaminated m

24.004 m 3

3 eculement, etc.

h l. ph

._w i e p <

c4

c. Irractatec co:ponents, control 3

m rod s. e t c.

Ci N/A N/A ma

d. Other (describe)

N/A N/A C1

2. Esti= ate of =ajor nuclide composition (by type of waste) a.

'! ! ?

t

  • 4 b.

e,.o r)

(;2. t h */

ne):7 12.80~

m1 b7

), grf.~

c-17h

, W~4 Sb125

.33%g c.

5, Y

4 d

\\

1 1

3. Solid Waste Disposition l

Nurber of Shienents Mode of Transportation Destinatien b) 6 Shirnents Tractor-Cask (14/190m)

Hanford-Richland, WA b) 1 Shipment Tractor-Cask (HH-100 Series i ) Hanford-Richland, Wa i

3.

Irradiated Fuel Shipments (Disposition) l Nu=ber of Ship ents Mode of Transportation Destination

'7 / A l

Shipped in k HICS at 175 Ft.3 Each 2 HICS at 49.9 Ft.3 Each j

1 HIC at 50 Pt.3 Each

. g.

c rim.nrunT9

.To l v 1 To87 throuch December 31, 1987 TABLE 3A EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT SOLID WASTE AND IRRADIATED FUEL SHIP.M TS A.

Solid waste shipped off-site for burial or disposal (not' irradiated fuel)

1. Type of waste UNIT f,%h g,0TAL T
a. 5 pent resins, filter sludges, m'

evecerator bottees, etc.

Ci N/A

b. Dry co=pressible vaste, conta=1nated a 3 ecuienent, etc.

c4 d, / A

c. Irradiatec cc ponents, control 3

m rod s. e t c.

Ci N/A mz

d. Other (describe)

Ci N/A

2. Estimate of major nuclide composition (bv type of waste)
a. N/A t

b.,n

~~

y t

=.

4 l

__ I

c. U/ A

]

T d.N/A

~'

g

3. Solid Waste Disposition Number of Shipments Mode of Transportation Destination N/A 3.

Irradiated Fuel Shipments (Disposition)

Nu=ber of Shipments Mode of Transportation Destination 20 Shirmants Pail Ca s k ( NuPa c 125B )

INEL - Scoville, ID {

,n-

d c

SOLIDIFIED CHEM-NUCLEAR LINERS July 1, 1987 through December 31, 1987 TABLE 3A EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT SOLID WASTE AND IRRADIATED FUEL SHIP.ETS A.

Solid waste shipped of f-site for burial or disposal (not' irradiated fuel)

1. Type of waste UNIT f,$h ES TpTAL
a. 5 pent resins, filter sludges,

m*

7.09 m3 evaporator bottoes, etc.

Ci 182. W *4ae.

55

b. Dry co=pressible waste, conta=inated m'

N/A N/A eculement, etc.

c4

c. Arraciatec co:ponents, control 3

m rod s, e t c.

N/A N/A Ci ma

d. Other (describe)

Ci N/A N/A

2. Esti= ate of =ajor nuclide composition (bv type of waste)
a. 9-00 7o,79%

Cs137 3 7, o] y h147 2. 216 %

cs13h

, 3 9%

b. N/A c.

I e

d.

  • n
3. Solid Waste Disposition Nur.ber of Shic=ents Mode of Transportation Destination a) 2 Shirments Tract or-Ca rkI ONSI 8-120u )

u --un17 co n

l B.

Irradiated Fuel Shipments (Disposition) i l

Number of Shipments Mode of Transportation Destination i

i Shipped in 2 Chem Nuclear 8-120 Steel Liners at 125.2 Ft.3 Each

_a_

r

.c TABLE 1 TYPICAL-LIOUID EFFLUENT LLO (Lower Limit of Detection) VALUES ASSUMPTIONS:

Sample volume = 1 liter = 1000 cc Sample counting time

= 1000 sec Sample counted with a 25% Ge(Li) for Gamma Emitters 1

ISOTOPE uCi/cc ll0 NOTES Gross Alpha a

4E-9 Counted with proportional counter 1

Gross Beta 7E-B Counted with proportional counter Tritium H-3 4E-6 Counted with liquid scintillation counter Krypton-85 Kr-85 1E-4 Xenon-131m Xe-131m 2E-5 Xenon-133 Xe-133 1E-6 Xenon-135 Xe-135 3E-7 Chromium-51 Cr-151 3E-6 M&ngar.ese-54 Mn-54 4E-7 Cobalt-58 Co-58 4E-7 Iron-59 Fe-59 9E-7 Cobalt-60 Co-60 6E-7 Zinc-65 Zn-65 1E-6 Zirconium-95 Zr-95 7E-7 Niobium-95 Nb-95 4E-7 Molybdenum-99 Mo-99 3E-7 Technetium-99m Tc-99m 3E-7 Silver-110m Ag-110m 6E-7 Antimony-125 Sb-125 9E-7 Cesium-134 Cs-134 SE-7 Cesium-136 Cs-136 4E-7 Cesium-137 Cs-137 SE-7 Barium-140 Ba-140 1E-6 Lanthanum-140 La-140 7E-7 Cerium-141 Ce-141 SE-7 Cerium-144 Ce-144 3E-6 lodine-131 1-131 3E-7 lodine-133 1-133 4E-7 Phosphorus-32 P-32 1E-6 These LLO values for liquid Iron-55 Fe-55 SE-8 sample analyses of gross alpha, Strontium-89 Sr-89 SE-8 P-32, Fe-55, Sr-89, and Sr-90 strontium-90 Sr-90 SE-8 are the same as Unit 1 which are Gross Alpha 1E-7 offsite vendor LLO values.

i i

)

r.

e TABLE 2 TYPICAL GASEOUS EFFLUENT ll0 (Lower Limit of Detection) VALUES ASSUMPTIONS:

Sample volume (Marinelli) 1640cc Sample volume (Particulate & Charcoal Filters) 5.7E8cc Sampling Rate 2 cfm or 5.66E4cc/ min Sampling Time 1 week or.1E4 min Sample volume (tritium bubbled thru water) 7.56E5cc Sampling Rate 75cc/ min Sampling Time 1E4 min Sample Counting Time:a & H-3 =20 min;

=10m.n;

=1000sec Sample Counters:

emitters

.25% Ge(Li) or Proportional Counter H-3 Liquid Scintillation Counter ISOTOPE Ci/cc LLO NOTES Gross Alpha n

1 E-15 Particulate Filter Paper Gross Beta 1E-14 Tritium H-3 1 E-10 Air bubbled thru water by a fritted disc or Fisher Milligan gas washer Krypton-85 Kr-85 SE-6 Marinelli Krypton-85m Kr-85m 2E-8 Krypton Kr-87 6E-8 Krypton-88 Kr-88 SE-0 Xenon-133 Xe-133 4E-8 Xenon-133m Xe-133m 1E-7 Xenon-135 Xe-135 2E-8 Xenon-135m Xe-135m 3E-7 Xenon-138 Xe-138 3E-7 Iodine-131 1-131 2E-8 Iodine-133 1-133 3E-8 Iodine-135 I-135 2E-7 Iodine-131 1-131 3E-14 Charcoal Filter Iodine-133 I-133 4E-14 Iodine-135 I-135 3E-13 Manganese-54 Mn-54 3E-14 Particulate filter Paper Iron-59 Fe-59 8E-14 Cobalt-58 Co-58 3E-14 Cobalt-60 Co-60 SE-14 linc-65 Zn-65 9E-14 Strontium-89 Sr-89 2E-14 Strontium-90 Sr-90 2E-14 Molybdenum-99 Mo-99 2E-14 Ruthenium-103 Ru-103 2E-14 Silver-110m Ag-110m 3E-14 Cesium-134 Cs-134 4E-14 Cesium-137 Cs-137 3E-14 Cerium-141 Ce-141 3E-14 Cerium-144 Ce-144 9E-14 i

i e',-

-e..

THREE MILE ISLAND Page 1 of 4 JOINT FREQUENCY TABLES i

THIRD QUARTER 1987 HOURS AT EACM WIND SPEED AND DIRECTION HOURS AT EACH WIND SPEED AND DIRECTION PERIOD of RECORD =

87070101 87093024 PERIOD OF RECORD =

87070101 87093024 STA81LITT CLASS:

A DT/DZ STA81LITY CLASS:

C DT/DZ ELEVATION:

SPEED SP100A DIRECTl0N:01100A LAPSE:DT150A ELEVATION:

SPEED:SP100A DIRECTl0N 01100A LAPSE:DT150A l

WIND SPEED (MPH)

WIND SPEED (MPH)-

WINO WIND DIRECTION 13 47 8 12 13 18 19 24

>24 TOTAL DIREC110N 13 47 81213181924

>24 TOTAL N

4 19 1

3 0

0 27 N

2 2

0 1

0 0

5 NNE 1

2 0

0 0

0 3

WNE 0

2 0

0 0

0 2-NE 0

5 1

0 0

0 6

NE O

O O

O 0

0 0

ENE 3

8 0

0 0

0 11 ENE 2

4 0

0 0

0 6

1 E

5 9

1 0

0 0

15 E

1 2

1 0

0 0

4 ESE 1

7 13 0

0 0

21 ESE 4

3 3

0 0

0 10 SE O

9 9

0 0

0 18 SE 1

5 3

1

.0 0

10

$$E 1

6 3

0 0

0 10

$$E 0

2 0

0 0

0 2

S 2

9 1

0 0

0 12 S

2 3

1 0

0 0

6 ssW 0

18 14 0

0 0

32 ssW 2

5 3

0 0

0 10 SW 8

29 9

1 0

0 47 sw 0

3 0

0 0

0 3

WSW 2

13 2

0 0

0 17 Wsw 2

1 0

0 0

0 3

i W

8 8

6 1

0 0

23 W

0 2

0 0

0 0

2 WWW 7

28 16 0

0 0

$1 WWW 0

1 1

0 0

0 2

NW 17 45 60 19 0

0 141 NW D

0 3

1 0

0 4

kNW 12 58 21 8

0 0

99 WNV O

2 4

1 0

0 7

TOTAL 71 2 73 157 32 0

0 533 TOTAL 16 37 19 4

0 0

76 PERIODS OF CALM (HOURS):

1 PERIODS OF CALM (Moves):

1 VARIABLE DIRECTION 145 VARIABLE DIRECT!DN 23 NOUR$ OF MIS $1Nf, DATA:

19 NOURS OF MISSING DATA:

19 HOURS AT EACH WIND SPEED AND DIRECTION HOUR $ AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD =

87070101 87093024 PERIOD OF REcotD =

87070101 87093024 ETABILITY CLASS:

B DT/DZ STABILITY CLASS:

0 DT/DZ ELEVAfl0N:

$PEEDISP100A DIRECT 10N:01100A LAPSE:tT150A ELEVATION:

SPEEDISP100A DIRECT 10N01100A LAPst:DT150A WIND SPEED (MPM)

WIND SPEED (MPM)

WIND WIND DIRECTION 13 47 8 12 13 18 19 24

>24 TOTAL DIRECTION 1*3 47 81213151924

>24 TOTAL W

1 2

0 0

0 0

3 x

7 3

1 0

0 0

11 NWE 2

0 0

0 0

0 2

WWE 7

13 0

0 0

0 20 NE 2

0 0

0 0

0 2

NE 3

22 0

0 0

0 25 EhE 1

2 0

0 0

0 3

Eht 8

28 3

0 0

0 39 E

3 3

0 0

0 0

6 E

13 34 5

0 0

0 52 ESE 1

4 3

0 0

0 8

ESE 7

19 22 0

0 0

48 SE 0

1 1

1 0

0 3

SE 5

14 11 1

0 0

31 sst 0

4 4

0 0

0 8

$5E 5

8 8

0 0

0 21 5

1 3

3 0

0 0

7 7

33 10 0

0 0

50 ssW 1

7 13 1

0 0

22 ssW 8

31 11 0

0 0

50

$W 5

6 4

0 0

0 15 sw 7

15 2

0 0

0 24 WsW 0

2 0

0 0

0 2

VSW 10 12 2

0 0

0 24 U

0 2

1 1

0 0

4 W

6 6

5 0

0 0

17 WWW 1

1 4

2 0

0 8

wwW 2

9 9

2 0

0 22 NW 4

6 6

1 0

0 17 NW 8

10 17 9

1 0

45 kWW 1

2 1

0 0

0 4

NNW 8

7 3

1 0

0 19 TOTAL 23 45 40 6

0 0 114 TOTAL 111 264 109 13 1

0 4 98 PERIODS OF CALM (NOURS):

1 PERIODS OF CALM (NOURS):

1 VARIA8tt DIRECTION 31 VARI ABLE DIRECTION 147 Mouts 07 MIS $thG DATA:

19 HOURS OF M!$$lhG DATA:

19 THREE MILE ISLAND Page 2 of 4 JOINT FREQUENCY TABLES THIRD QUARTER 1987 McLas A! EACH WIND SPEF0 AND DIRECT!OW NOURS AT EACH WIND SPEED AND DIRELTION PERIOD OF RECORD =

87070101 87093024 PERICD OF RECC*o =

87070101 87093024 STABILITY CLASS:

E 07/02 STABILITY CLASS:

G DT/D2

' ELEVATION:

SPfED SP100A DIRECTION:DI100A LAPSE DT150A ELEVATION:

SPEED SP100A DIRECT 10N:01100A LAPSE DT150A WIND SPEED (MPM)

WIND SPEED (MPM)

WIND WIND DIRECT!0N 13 47 8 12 13 18 19 24

>24 TOTAL DIRECTION 13 47 8 12 13 18 19 24

>24 TOTAL N

20 37 1

0 0

0 58 N

1 1

0 0

0 0'

2 NME 12 12 1

0 0

0 23 NNE 1

0 0

0 0

0 1

NE 17 9

1 0

0 0

27 NE 5

1 0

0 0

0 6

ENE 13 14 0

0 0

0 27 ENE 3

2 0

0 0

0 5

E 28 19 0

0 0

0 47 E

4 2

0 0

0 0

6 ESE 15 9

2 0

0 0

26 ESE 3

0 0

0 0

0 3

SE 17 7

1 0

0 0

13 SE 5

0 0

0 0

0 5

SSE 8

6 1

0 0

0 15

$$E 4

1 0

0 0

0 9

13 0

0 0

0 22 3

1 0

0 0

0 4

SSV 12 21 6

0 0

0 39 SSW 6

2 0

0 0

0 8

SW 13 19 4

0 0

0 36 SV 7

0 0

0 0

0 7

WSW 19 17 0

0 0

0 36 WSV 5

1 0

0 0

0 6

W 31 21 3

0 0

0 55 W

7 4

0 0

0 0

11 WW 25 22 4

0 0

0 51 WW 1

1 0

0 0

0 2

W 21 28 15 0

0 0

64 W

3 1

0 0

0 0

4 NW 25 33 7

0 0

0 65 kW 2

2 0

0 0

0 4

TOTAL 285 287 46 0

0 0 618 TOTAL 60 19 0

0 0

0 79 PERIODS 0" CALM (HOURS):

1 PERIODS OF CALM (HOURS):

1 VARIABLE 11RECTION 328 VARI ABLE DIREC110N 45 NOURS OF MISSING DATA:

19 HOURS OF hlS$1NG DATA:

19 HOURS AT EACH WIND SPEED AND DIRECTION HQ)RS AT EACH WIND SPF.ED AND DIRECTION PERIOD of RECORD =

87070101 87093024 PERIOD OF RECORD =

87070101 87093024 STABILITY CLASS:

F DT/DZ STABILITY CLASS:

ALL 0T/02 ELEVAfifN:

SPEED SP100A DIRECT 10N:01100A LA*SE:DT150A ELEVAfloN

$ PEED SP100A DIRECT 10N 01100A LAPSE DT150A 3r................

WIND SPEED (MPM)

WIND SPEED (MPM)

WINT WIND DIRECTION 13 47 81213181924

>24 TOTAL DIP.ECT10N 13 47 8 12 13 18 19 24

>24 TOTAL N

10 10 0

0 0

0 20 N

45 74 3

4 0

0 126 WWE 3

1 0

0 0

0 4

NNE 26 30 1

0 0

0 57 NE 4

1 0

0 0

0 5

NE 31 38 2

0 0

0 71 ENE 10 0

0 0

0 0

10 ENE 40 58 3

0 0

0 101 E

5 5

0 0

0 0

10 E

$9 74 7

0 0

0 140 ESE 10 4

0 0

0 0

14 ESE 41 46 43 0

0 0 130 SE 7

1 0

0 0

0 8

SE 35 37 25 3

0 0 100

$$E 6

2 0

0 0

0 8

$$E 24 29 16 0

0 0

69 5

12 1

0 0

0 0

13 36 63 15 0

0 0 114 554 11 3

0 0

0 0

14 SSW 40 87 47 1

0 0 175 SW 14 8

0 0

0 0

22 SV 54 80 19 1

0 0 154 Wfu 18 6

0 0

0 0

24 WSW 56 52 4

0 0

0 112 W

14 12 3

0 0

0 29 W

66 55 18 2

0 0 -141 WN 23 6

0 0

0 0

29 WW 59 68 34 4

0 0 165 NJ 15 11 0

0 0

0 26 W

63 101 101 30 1

0 301 IW 14 21 0

0 0

0 35 NW 62 125 36 10 0

0 233 f01AL 176 92 3

0 0

0 271 TOTAL 742 1017 374 55 1

0 2189 PERICOS OF CALM (MOURS):

1 PERIODS OF CALM (HOURS):

1 VARIABLE DIRECTION 143 YARIABLE DIRECTION 862

  • Ut10F MISSING DATA:

19 HOURS OF MIS $1NG DATA:

19

~

Page 3 of 4

~*

THREE MILE ISLAND JOINT FREQUENCY TABLE FOURTH QUARTER 1987 HOURS AT EACH WIND SPEED AND DIRECTION MOURS AT EACM Wim SPEED AND DIRECTION PERIOD OF RECORD e 87100101-87123124 PERIOD OF RECORD =

87100101 87123124 STABILITT CLASS:

C DT/DZ STABILITY CLASS:

A 0T/02 ELEVAfl0N:

SPEED SP100A DIRECTION:DI100A LAPSE:DT150A ELEVATION:

SPEED SP100A DIRECT 10N:01100A LAPSE DT150A WIND SPEED (MPM)

WIND SPEED (MPM)

WIND DIR*CT ION 13 4i7-8 12 13 18 19 24

>24 TOTAL DIRECTION 13 47 8 12 13 18 19 24

>24 TOTAL WIWD N

0 5

8 0

0 0

13 N

2 1

1 1

1 0

6 NNE O

O 1

0 0

0 1

NME O

O O

O 0

0 0

NE 1

0 0

0 0

0 1

NE O

O 0

0 0

0 0

EWE O

O O

0 0

0 0

ENE 0

0 0

0 0

0 0

E O

O 0

0 0

0 0

E O

'J 0

0 0

0 0

ESE 3

2 2

0 0

0 7

ESE 1

3 1

0 0

0 5

SE 1

2 0

0 0

0 3

SE 1

1 2

0 0

0 4

$$E 1

0 0

0 0

0 1

SSE O

0 0

0 0

0 0

S 1

2 3

2 0

0 8

5 1

1 2

0 0

0 4

$$W 0

4 12 1

0 0

17

$$W 0

1 0

0 0

0 1

SW 2

7 5

0 0

0 14 SW 0

1 0

0 0

0 1

L'SW 5

7 4

0 0

0 16 WSW 0

0 1

0 0

0 1

u 1

5 3

4 0

0 13 W

0 0

0 0

0 0

0 WWW 2

3 5

2 0

0 12 WWV 0

0 3

2 0

0 5

WW 1

6 9

12 5

0 33 kW 0

1 4

3 3

0 11 Nww 3

11 7

1 2

0 24 NWV 0

1 3

2 2

1 9

TOTAL 21 54 59 22 7

0 163 TOTAL 5

10 17 8

6 1

47 PERIOOS OF CALM (HOURS):

0*

PERIODS OF CALM (HOURS):

0 VARIA8tE DIRECTION 8

VARIABLE DIRECTION 37 HOURS OF MIS $1NG DATA:

13 MOURS OF MISSING DATA:

13 HOURS AT EACH WIND SPEED AND DIRECTION HOURS AT EACM WIND SPEED AWD DIRECTION PERIOD OF RECORD =

87100101 87123124 PERIOD OF RECORD =

87100101 87123124 STABILITY CLASS:

D DT/DZ STABILITY CLAS$t 8

D?/DZ ELEVAilDN SPEED SP100A DitECT10N:D1100A LAPSE:DT15CA ELEVAT!DN:

SPEED SP100A DIRECT 10W:01100A LAPSE:DT150A WIND SPEED (MPM)

WIND SPEED (MPM)

WIND DIRECTION 13 47 8 12 13 18 19 24

>24 TOTAL DIRECT 10N 13 47 81213181924

>24 TOTAL WIND N

0 1

1 0

0 0

2 N

3 8

11 1

0 0

23 hhE 0

0 0

0 0

0 0

NWE 1

9 4

0 0

0 14 WE 0

0 0

0 0

0 0

NE 1

8 1

0 0

0 10 ENE O

0 0

0 0

0 0

EhE 0

3 9

0 0

0 12 E

O 1

0 0

0 0

1 E

5 9

26 1

0 0

41 ESE 0

1 0

0 0

0 1

ESE 3

9 16 5

0 0

33 SE 1

1 0

0 0

0 2

SE 6

7 5

0 0

0 18 SSE O

O O

O 0

0 0

SSE 1

6 4

1 0

0 12 S

0 3

0 0

0 0

3 4

22 10 2

0 0

38 i

$$w 1

3 3

0 0

0 7

SSW 3

10 14 2

0 0

29 SW 0

0 0

0 0

0 0

SW 4

10 6

1 0

0 21 WSW i

1 1

0 0

0 3

WSW 3

10 6

2 0

0 21 W

0 1

2 1

1 0

5 W

9 10 30 24 2

0 75 I

wwV 0

0 3

1 0

0 4

WWV 3

11 52 38 12 0 116

{

WV 0

0 2

2 4

4 12 WV 3

8 43 74 38 4 170 J

kvV 3

2 4

1 2

0 12 NWV 5

11 16 15 7

3 57 TOT AL 6

14 16 5

7 4

52 TOTAL 54 151 253 166 59 7 690 PER1005 0F CALM (WOURS):

0 PERl005 0F CALM (HOURS):

0 VARIABLE DIRECTION 81 HOUR $ OF MIS $lkG DATA:

13 VARIABLE DIRECT 10N 10 HOURS OF MIS $!NG DATA:

13 i

.o-

/

Page 4 of 4 o..

THREE MILE ISLAND JOINT FREQUENCY TABLE FOURTH QtTARTER 1987 HOURS AT EACH WIND SPEED AND DIRECTION HOLAS AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD =

87100101 87123124 PERIOD OF RECORD =

87100101 87123124 STABILITY CLASS:

E DT/DZ STABILITY CLASS:

G DT/DZ ELEVATION:

SPEED:SP100A DIRECT 10N:01100A LAPSE:DTtSOA ELEVATION:

SPEED SP100A DIRECTION:Dl100A LAPSE:DT150A WIND SPEED (MPM)

WIND SPEED (MPH)

WIND WIND DIRECTION 13 4*7 8 12 13 18 19 24

>24 TOTAL DIRECTION 1-3 47 8-12 13 18 19 24

>24 TOTAL N

16 27 9

2 0

0 54 N.

14 8

0 0

0 0

22 NnE 11 10 3

0 0

0 24 NNE 6

0 0

0 0

0 6

NE 10 9.

1 0

0 0

20 NE 7

0 0

0 0

0 7

ENE 11 14 4

0 0

0 29 ENE 6

0 0

0 0

0 6

E 13 13 8

2 0

0 36 E

10 4

0 0

0 0

14 ESE 13 15 13 0

0 0

41 ESE 9

4 0

0 0

0 13 SE 13 9

2 0

0 0

24 SE 6

0 0

0 0

0 6

SSE 12 12 6

0 0

0 30 SSE 9

0 0

0 0

0 9

t 3

17 3

1 0

0 24 5

6 3

0 0

0 0

9 SSV 10 17 12 1

0 0

40 SSW 4

7 3

0 0

0 14 S')

12 21 8

1 0

0 42 SW 9

5 0

0 0

0 14 WSV 9

35 10 2

0 0

56 WSW 5

1 0

0 0

0 6

W 17 44 25 5

0 0

91 W

8 2

0 0

0 0

10 VvW 19 15 26 8

0 0

68 WNW 10 3

1 0

0 0

14 NW 16 16 30 10 1

0 73 NW 14 4

1 0

0 0

19 NNW 18 26 19 8

0 0

71 NNW 16 11 1

0 0

0 28 TOTAL 203 300 179 40 1

0 723 TOTAL 139 52 6

0 0

0 197 PERICOS OF CALM (MOURS):

O PERICOS OF CALM (MOURS):

0 VARIABLE DIRECTION 244 VARIABLE DIRECTION 119 HOURS OF MISSING DATA:

13 HOURS OF MIS $1NG DATA:

13 HOURS AT EACH WIND SPEED AND DIRECTION H0JRS AT EACH WIND SPEED AND DikECTION PERIOD OF RECORD =

87100101-87123124 PERIOD OF RECORD =

87100101 87123124 STABILITY CLASS:

F DT/DZ STABILITT CLAS$t ALL DT/DZ E*.EVATION:

SPEED:SP100A DIRECT!0N:01100A LAPSE:DT150A ELEVATION:

SPEED:SP100A DIRECil0N:01100A LAPSE:DT150A WIND SPEED (MPN)

WIND SPEED (MPM)

Wik3 WIND DIRECTION 13 47 8 12 13 18 19 24

>24 TOTAL DIRECTION 1*3 47 8 12 13 18 19 24

>24 TOTAL N

6 10 0

0 0

0 16 N

41 60 30 4

1 0 136 NNL 13 2

0 0

0 0

15 NME 31 21 8

0 0

0 60 NE 14 3

0 0

0 0

17 NE 33 20 2

0 0

0 55 ENE 9

5 0

0 0

0 14 EhE 26 22 13 0

0 0

61 E

9 4

0 0

0 0

13 E

37 31 34 3

0 0 105 ESE 7

5 0

0 0

0 12 E>E 34 39 32 5

0 0 112 SE 18 3

0 0

0 0

21 SE 46 23 9

0 0

0 78 SSE 8

1 0

0 0

0 9

SSE 31 19 to 1

0 0

61 S

8 2

0 0

0 0

10 S

23 50

  • 8 5

0 0

SSW 22 13 2

0 0

0 37 SSW 40 55 46 4

0 0 145 SW 9

6 0

0 0

0 15 SW 36 50 19 2

0 0 107 WSW 16 6

0 0

0 0

22 VSW 39 60 22 4

0 0 125 W

23 6

0 0

0 0

29 W

58 68 60 34 3

0 223 WNW 22 2

0 0

0 0

24 WNW 56 34 90 51 12 0 243 NW 28 5

1 0

0 0

34 WW 62 40 90 101 51 8 352 DW 13 20 2

0 0

0 35 NNW 58 82 52 27 13 4 236 TOTAL 225 93 5

0 0

0 323 TOTAL 653 674 535 241 80 12 2195 PERICOS OF CALM (MOURS):

0 PERICOS OF CALM (MOURS):

0 VARIABLE DIRECTION 194 VARIABLE DIRECTION 693 MOURS OF MIS $ LNG DATA:

13 NOUR$ OF M]SSING DATA:

13