ML20141N144

From kanterella
Jump to navigation Jump to search

Forwards Training Matls in Response to 851030 Request for Addl Info Re Course of Action & Draft SER (NUREG-1177).Matl Meets Commitment Made in Rev 4 of Course of Action
ML20141N144
Person / Time
Site: Davis Besse 
Issue date: 02/26/1986
From: Williams J
TOLEDO EDISON CO.
To: Harold Denton
Office of Nuclear Reactor Regulation
Shared Package
ML20141N145 List:
References
RTR-NUREG-1177 1242, TAC-61015, NUDOCS 8603040410
Download: ML20141N144 (4)


Text

-

TOLEDO

%ms EDISON Docket No. 50-346 (OE S

[419)243 2300 License No. NPF-3 l' ' 85"#'

Serial No. 1242 February 26, 1986 Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation United States Nuclear Regulatory Commission Washington, D.C.

20555

Dear Mr. Denton:

The enclosed training materials are in response to Question 29 in the NRC's Request for Additional Information (31 Questions) dated October 30, 1985 (Log No. 1844), on the Davis-Besse Course of Action (COA) and the draft Safety Evaluation Report (SER), Draft NUREG-1177, dated January 29, 1986 (Log No. 1914). Toledo Edison responded to Log No. 1844 with Revision 4 to the COA (Serial No. 1182) and to Log No. 1914 with Serial No. 1242.

The enclosed training programs were not available at the time of those responses.

These training materials meet the commitment made in Revision 4 of the COA to submit the training programs for infrequent, critical and difficult tanks.

Included in the this transmittal are:

1.

Cross-reference, lesson plan to item.

2.

Lesson Plan RES-OPS-002.00, " Rapid Feedwater Reduction".

3.

Lesson Plan RES-0PS-007.00, "EP 1202.01 Infrequent operations" 4.

Lesson Plan COP-OLC-001.00, Att. 36, " Loss of Instrument Air AB 1203.36",

5.

Lesson Plan RES-OPS-008.00, " Starting of Primary Water Storage Tank Transfer Pumps",

6.

Lesson Plan RES-0PS-006.00, "Draeger Cas Analyzer Use Function an Applicable Procedure Review",

f 7.

Lesson Plan COP-OLC-001.00, Attachment 26. " Serious Control Room f

Fire AB 1203.26" pfl 9603040410 860226 PDR ADOCK 05000346 V

PDR THE TOLEDO EDISON COMPANY EDISON PLAZA 300 MADISON AVENUE TOLEDO. OHIO 43652

l D;ck t No. 50-346 License No. NFP-3 Serial No. 1242 January 14, 1986 Page 2 8.

Lesson Plan GOP-OLC-001.00 Att. 28, " Loss of AC Bus Power Sources AB 1203.28",

9.

Lesson Plan GOP-OLC-001.00 Att. 41, " Loss of NNI Power AB 1203.41",

and 10.

Memo Rick Simpkins to All Licensed Individuals, STAS, and Non-Licensed Operators, " Restart Training Practical Requirements",

dated December 23, 1985.

We feel that the information included in this transmittal adequately answers Question 29 in your initial request.

Very truly yours.

/!L::'T W:RRS:lah attachments ec: DB-1 NRC Resident Innpector x

1

\\

Serial Na. 1242 Attechment 1 TRAINING PROGRAM FOR INFP.EQUENTLY PERFORMED TASRS 1.

EP 1202.01, RPS, SFAS, SFRCS Trip or S/G Tube Rupture COMMENT:

See RES-OPS-002, RES-OPS-007, GOP-OLC-001-Att 36, and Practical Requirements Item No. 1 1 2.

AB 1203.12, Serious Station Fire COMMENT:

This procedure is currently being revised and deleted from the Course of Action Decument as required for Restart.

Training will be conducted on the new procedure when revised.

3.

AB 1203.03, Cooldown Without the BWST and No Offsite Power COMMENT:

See RES-OPS-004 and Practical Requirement No. 3.0 4.

AB 1203.10, Condensate Tube Leak COMMENT:

C & MP currently relies on on-the-job training for placing condensate polishers in service.

Training was provided in the past on condenser tube leak location.

Job / Task analysis is currently underway which will identify proper training requirements for these items.

5.

AB 1203.14, Toxic Gas and Liquid Release COMMENT:

See RES-OPS-006.

RMT's currently receive training on Draeger Gas Analysis.

6.

AB 1203.26, Serious Control Room Fire COMMENT:

See GOP-OLC-001-Att 26 and Practical Requirements Item No. 4.0.

7.

AB 1203.28, Loss of AC Bus Power Sources COMMENT:

See GOP-OLC-Att 28.

8.

A5 1203.36, Loss of. Instrument Air COMMENT:

See GOP-OLC-001-Att.16 and Practical Requirements Item No. 1 and No.

"2.

9.

AB 1203.41, Loss of NNI Power COMMENT:

See GOP-OLC-001-Att 41

ADDITIONAL INFREQUENTLY PERFORMED TASKS 10.

Transferring MCCF13 from normal to alternate CCMNINT:

See Practical Requirement No. 7.

11.

Reset Emergency Diesel Generator Overspeed Trip I

COMMENT:

See Practical Requirement No. 8 12.

Manually piece Main Turbine on Turning Gear COMMENT:

See Practical Requirement No. 9 12.

Reset Auxiliary Feed Pumps from Overspeed Trip Condition COMMENT:

See Practical Requirement No. 5 i

i t

m m

m m.

-. m m.

--