C ATTACHMENT 1 ASME SECTION XI PUMP AND VALVE PROGRAM CHANGES TO CALLAWAY NUCLEAR PLANT INSERVICE TESTING PROGRAM ITEM 1: CHANGE: Add Relief Request #P08 BASIS FOR CHANGE: As described in Relief Request #P08 ITEM 2: CHANGE: Add Relief Request #V04 BASIS FOR CHANGE: As described in Relief Request #V04 ITEM 3: CHANGE: Add Relief Request #KA 2 and delete Relief Request #V01 BASIS FOR CHANGE: Relief Request #KA 2 replaces Relief Request #V01 for valve KA-V-204.

Relief Request #V01 is no longer necessary since other relief requests (#BB7, #BG1, #BL1, and #EG1) cover valves BB-V-118, -148,

-178, -208, BG-8381, BL 8046, and EG-V-204.

The other valves listed in Relief Request

  1. V01 do not require relief.

ITEM 4: CHANGE: Add Relief Request #V05 BASIS FOR CHANGE: As described in Relief Request #VOS ITEM 5: CHANGE: Revise. Maximum Allowable Stroke Times for AL-HV-32, AL-HV-33, AL-HV-34, AL-HV-35, AL-HV-36, BB-HV-8000A, BB-HV-8000B, BG-HV-8357B, BN-HV-8806A, BN-HV-8806B, EF-HV-31, EF-HV-32, EF-HV-33, EF-HV-34, EF-HV-43, EF-HV-45, EF-HV-46, EF-HV-51, EF-HV-59, EF-HV-60, EG-HV-69A, EG-HV-69B, EG-HV-70A, EG-HV-70B, EJ-HV-8716A, EJ-HV-8716B, EJ-FCV-610, EJ-HV-8804A, EJ-HV-8804B, EM-HV-8801A, EM-HV-8801B, EM-HV-8803A, EM-HV-8803B, EM-HV-8821A, EM-HV-8821B, EN-HV-15, EN-HV-16, AL-HV-30, AL-HV-31, EJ-HV-8809A, EJ-HV-8809B, EJ-HV-8840 BASIS FOR CHANGE: Due to now or revised design documents for the valves.

ITEM 6: CHANGE: Remove revision bars from revision 3 pages.

AW(t 8507120107 050620 g

DR ADOCK 05000 3

m ATTACHMENT 2 t

INSERVICE TESTING PROGRAM CALLAWAY NUCLEAR PLANT REVISION 4 MAY 24, 1985 PREPARED BY:

REVIEWED BY:

$(/utMr 4 /VEW Yh WARREN A. WITT R

D AFF0hh ISI ENGINEER

[gg $UPERVfMNG ENGINEER

INSERVICE TESTING PROGRAM ISI CLASS 1, 2 a 3 PUMPS Rev.

Date Page CALLAWAY NUCLEAR PLANT 4

5/85 1 of 2 TEST PARANETERS ISI P&IO and NOTES PUMP PUMP NAME CLASS Coordinate:.

NUMBER INLET DIFF.

FLOW VIBRA-PEED PRES. PRES.

RATE ATION Note 1 Motor Driven PALO1 A Auxiliary Feedwater 3

M-02AL01 N/A YES YES YES YES RR* P07 Pump A E-4 RRd PO4, P08,P05 RR7 P0/

Note 1 Motor Driven M-02AL01 PALO& 8 Auxiliary Feedwater 3

G-4 N/A YES YES YES YES RR= POS, P08,904 Pump B Note 1 Turbine Driven M-02ALO1 PALO2 Auxiliary Feedwater 3

B-4 &

YES YES YES YES YES RR# P07 Pump M-02FCO2 RR* PC4, P08,005 h,'Pf6 E

Centrifugal M-02BG03 Charging Pump 2

C-5 N/A YES YES NO YES P07, P03' PSG05 A P08,304 I

Note L entrifugal S02SG03 RR= P06, Charging Pump 2

B-5 N/A YES YES NO YES P07,P03, l

DBGOS B l

P08,PO4

(

Note 1 Essential Service PEF 01 A Water Pump 3

M-U2EF01 N/A YES YES YES YES Note 2 G-6 RR# P07, P08,PO4 PEF 01 B Essential Service M-V2EF01 Note Water Pump 3

C-6 N/A YES YES YES YES RR# P07.

P08, PO4 Note 1 Component Cooling PEG 01 A Water Pump 3

M-02EG01 N/A YES YES YES YES RR# P08 RR# PG4 G-4 RR# P07 Note 1 Component Cooling M-02EG01 N/A YES YES YES YES RR# P08 PEG 01 8 Water Pump 3

0-4 pp, D04 RR# P07 P8 PEG 01 C Component Cooling 3

M-02EG01 N/A YES YES YES YES Water Pump E-4 RRd 904 RRe P07

'"9 N/A YES YES YES YES

  1. P08 h0*0"'"

PEG 01 0 3

,,r u

RRn P07

~

f INSERVICE TEST!NG PROGRAM ISI CLASS 1. 2 & 3 PUMPS CALLAWAY NUCLEAR PLANT Rev.

Date Page 4

5/L5 2 of 2 TEST PARAMETERS ISI P&ID and NOTES PUMP PUP'7. NAXE NUMBER CLASS Coordinates INLET DIFF.

FLOW VISRA.

SPEED

,ATION PRES.

PRES.

RATE Note 1 Residual Heat M-02EJ01

$' PO,

PEJ01 A Removal Pump 2

G-6 N/A YES YES YES TES P08.P07 Residual Heat M-02EJ01 PEJ01 B RR# Pul Removal Pump 2

C-6 N/A YES YES YES YES ' RR# PO4, P08, F07 PEM01 A Safety Injection RR# P08 j

Pump 2

M-02EM01 N/A YES YES YES YES RR* PO4 E-6 l

RR# P07 l

Note 1 1

PEM01 B Safety Injection 2'

M-02EM01 N/A YES YES YES YES RRf P08 Pump 0-6 RR# PO4 RR# P07

~

Containment M-02EN01 Note 1 PEN 01 A Spray Pump 2

G-6 N/A YES YES YES YES RR# PO4,

/

P08,P07 Containment Note 1 PEN 01 B Spray Ptimp 2

M-02EN01 N/A YES

.YES YES YES B-6 RR# PO4, P08,P07 l

Note 1 l

Emergency Fuel

((,# @,

PJE01 A 011 Transfer Pump 3

M-02JE01 N/A NO YES

'NO YES E-7 P08,p04 Emergency Fuel Note 1 PJE01 B 011 Transfer Pump 3

M-02JE01 RR# P07 N/A 'l NO YES NO YES RRs 002, A-7 l,

P08 pg f

k

C Pcgs 3 INSERVICE TESTING PROGRAM SY VLV-NUMBER

  • -P+1D
  • SIZE TYP AT POS DIR TST TM MAX *R/R
  • NOTES
  • AE FCV0510 M-02AE01 E B 14" AG A0 0 C

NA 12 AE FCV0520 M-02AE01 C B 14" AG A0 0 C

NA 12 AE FCV0530 M-02AE01 B B 14" AG A0 0 C

NA 12 AE FCV0540 M-02AE01 G B 14" AG A0 0 C

NA 12 AE FCV0550 M-02AE01 E B 4"

GL A0 C C

NA 12 AE FCV0560 M-02AE01 C B 4"

GL A0 C C

NA 12 AE FCV0570' M-02AE01 A B 4"

GL A0 C C

NA

~12 AE FCV0580 M-02AE01 G B 4"

GL A0 C C

NA 12 e

e

Pago 5 INSERVICE TESTING PROGRAM SY VLV-NUMBER

  • -P+ID
  • SIZE TYP AT POS DIR TST TM MAX *R/R
  • NOTES
  • AL HV 0005 M-02AL01 H-6 2 B 4"

GL MO O C

NA AL HV 0006 M-02AL01 G-6 2 B 4"

GL A0 0 0

NA 3

AL HV 0007 M-02AL01 F-6 2 B 4"

GL MO O C

NA AL HV 0008 M-02AL01 E-6 2 B 4"

GL A0 0 0

NA 3

AL HV 0009 ~

M-02AL01 D-6 2 B 4"

GL MO O C

NA AL HV 0010 M-02ALO1 D-6 2 B 4"

GL A0 0 0

NA 3

AL HV 0011 M-02AL01 C-6 2 B 4"

GL MO O O

NA AL HV 0012 M-02E01 B-6 2 B 4"

GL A0 0 0

NA 3

l AL HV 0030 M-02ALO1 F-3 3 B 6"

BT MO C 0

BT OP 20 6

AL HV 0030 M-02AL01 F-3 3 B 6"

BT MO C 0

PIT RR l

AL HV 0031 M-02ALOL E-3 3 B 6"

BT MO C 0

BT OP 20 6

AL HV 0031 M-02ALO1 E-3 3*B 6"

BT M0 C 0

PIT RR l

AL HV 0032 M-02AL01 C-3 3 3 8"

BT MO C 0

BT OP 22 6

AL HV 0032 M-02AL01 C-3 3 B 8"

BT MO C 0

PIT RR l AL HV 0033 M-02ALO1 B-3 3 B 8"

BT MO C 0

BT OP 22 6

AL HV 0033 M-02E01 B-3 3 B 8"

BT MO C 0

PIT RR l AL HV 0034 M-02ALOL H-3 3 B 8"

GA MO O C

BT OP 40 6

AL HV 0034 M-02AL01 H-3 3 B 8"

GA' MO O C

PIT RR l AL HV 0035 M-02AL01 D-3 3 5 8"

GA MO O C

BT OP 40 6

AL HV 0035 M-02AL01 D-3 3 3 8

GA MO O C

PIT RR l AL HV 0036 M-02AL01 B-3 3 B 10" GA MO O C

BT OP 40 6

AL HV 0036 M-02AL01 B-3 3 B 10" GA MO O C

PIT RR AL V 0001 M-02AL01 B-4 3 C 10" CK SA C 0

CVP OP AL V 0001 M-02ALO1 B-4 3 C 10" CK SA C 0

CVT CS AL-1 AL V 0002 M-02AL01 D-4 3 C 8"

CK SA C 0

CVP OP AL V 0002 M-02ALO1 D-4 3 C 8"

CK SA C 0

CVT CS AL-1.

AL V 0003 M-02ALO1 H-4 3 C 8"

CK SA C 0

CVP OP AL V 0003 M-02AL01 H-4 3 C 8"

CK SA C 0

CVT CS AL-1 AL V 0006 M-02ALO1 F-4 3 C 6"

CK SA C 0

CVT RR AL-2 4,5 AL V 0009 M-02AL01 E-4 3 C 6"

CK SA C 0

CVT RR AL-2 4,5 AL V 0012 M-02AL01 C-4 3 C 8"

CK SA C 0

CVT RR AL-2 4 AL V 0015 M-02AL01 B-4 3 C 8"

CK SA C 0

CVT RR AL-2 4 AL V 0029 M-02AL01 G-5 3 C 2"

CK SA C 0

CVT OP AL V 0030 M-02AL01 H-5 3 C 6"

CK SA C 0

CVT CS AL-1 5 AL V 0033 M-02AL01 F-7 2 C 4"

CK SA C 0

CVT CS AL-1 5 AL V 0036 M-02AL01 H-7 2 C 4"

CK SA C 0

CVT CS AL-1 5 l

AL V.

0041 M-02AL01 F-5 3 C 2"

CK SA C 0

CVT OP AL V 0042 M-02AL01 D-5 3 C 6"

CK SA C 0

CVT CS AL-1 5 AL V 0045 M-02AL01 C-7 2 C 4"

CK SA C 0

CVT CS AL-1 5 AL V 0048 M-02AL01 D-7 2.C 4"

CK SA C 0

CVT CS AL-1 5 Al V 0053 <

M-02AL01 B-5 3 C 3"

CK SA C 0

CVT 0P l

AL V 0054 M-02AL01 B-5 3 C 8"

CK SA C 0

CVT CS AL-1 5 l

AL V 0057 M-02AL01 E-7 2 C 4"

CK SA C 0

CVT CS AL-1 5

~~

AL V 0062 M-02AL01 G-7 2 C 4"

CK SA C 0

CVT CS AL-1 5 l

AL V 0067 M-02AL01 D-7 2 C 4"

CK SA C 0

CVT CS AL-1 5 AL V 0072 M-02AL01 B-7 2 C 4"

CK SA C 0

CVT CS AL-1 5 n

l l

Pago 6

INSERVICE TESTING PROGRAM SY VLV-NUMBER

  • -P+ID
  • SIZE TYP AT POS DIR TST T11 MAX *R/R
  • NOTES
  • BB 8378A M-02BB01 E-4 1 C 3"

CK SA 0 0/C NA BB 8378B M-02BB01 E-4 1 C 3"

CK SA 0 O/C NA BB 8379A M-02BB01 E-7 1 C 3"

CK SA 0 0/C NA BB 8379B M-02BB01 E-7 1 C 3"

CK.SA 0 0/C NA l

BB 8948A M-02BB01 E-4 1 A,C 10" CK SA C 0

AT CS V05 7 BB 8948A M-02BB01 E-4 1 A,C 10" CK SA C 0

CVT CS BB-1 5 l

BB 8948B M-02BB01 D-4 1 A,C 10" CK SA C 0

AT CS V05 7 BB 8948B M-02BB01 D-4 1 A,C 10" CK SA C 0

CVT CS BB-1 5 l

BB 8948C M-02BB01 C-6 1 A,C 10" CK SA C 0

AT CS V05 7 BB 8948C M-02BB01 C-6 1 A,C 10" CK SA C 0

CVT CS BB-1 5 l

BB 8948D M-02BB01 E-6 1 A,C 10" CK SA C 0

AT CS V05 7 BB 8948D M-02BB01 E-6 1 A,C 10" CK SA C 0

CVT CS BB-1 5 l

BB 8949A M-02BB01 E-5 1 A,C 6"

CK SA C 0

AT CS V05 7 BB 8949A M-02BB01 E-5 1 A,C 6"

CK SA C 0

CVT RR BB-2 5 l

BB 8949B M-02BB01 C-5 1 A,C 6"

CK SA C 0

AT CS V05 7 BB 8949B M-02BB01 C-5 1 A,C 6"

CK SA C 0

CVT RR BB-3 5 l

BB 8949C M-02BB01 C-6 1 A,C 6"

CK SA C 0

AT CS V05 7 BB 8949C M-02BB01 C-6 1 A,C 6"

CK SA C 0.

CVT RR BB-3 5 l

BB 8949D M-02BB01 G-6 1 A,C 6"

CK SA C 0

AT CS V05 7 BB 8949D M-02BB01 G-6 1 A,C 6"

CK SA C 0

CVT RR BB-2 5 l

BB PV 8702A M-02BB01 E-4 1 A 12" GA MO C C,

AT CS V05 7 BB PV 8702A M-02BB01 E-4 1 A 12" GA M0 C C

BT CS 120 BB-6 5,6 BB PV 8702A M-02BB01 E-4 1 A 12" GA M0 C C

PIT RR l

BB PV 8702B M-02BB01 H-6 1 A 12" GA M0 C C

AT CS V05 7 BB PV 8702B M-02BB01 H-6 1 A 12" GA MO C C

BT CS 120 BB-6 5,6 BB PV 8702B M-02BB01 H-6 1 A 12" GA M0 C C

PIT RR l

BB V 0001 M-02BB01 D-5 1 A,C 1.5" CK SA C 0

AT CS V05 7 BB V 0001 M-02BB01 D-5 1 A,C 1.5" CK SA C 0

CVT RR BB-4 5 l

BB V 0022 M-02BB01 D-4 1 A,C 1.5" CK SA C 0

AT CS V05 7 BB V 0022 M-02BB01 D-4 1 A,C 1.5" CK SA C 0

CVT RR BB-4 5 l

BB V 0040 M-02BB01 D-6 1 A,C 1.5" CK SA C 0

AT CS V05 7 BB V 0040 M-02BB01 D-6 1 A,C 1.5" CK SA C 0

CVT RR BB-4 5 l

BB V 0059 M-02BB01 E-6 1 A,C 1.5" CK SA C 0

AT CS V05 7 BB V 0059 M-02BB01 E-6 1 A,C 1.5" CK SA C 0

CVT RR BB-4 5 l

l l

l l

l i

Pggs 7 INSERVICE TESTING PROGRAM SY VLV-NUMBER

  • -P+ID
  • SIZE TYP AT POS DIR TST TM MAX *R/R
  • NOTES
  • BB 8010A M-02BB02 H-7 1 C 6"

RV SA C 0

RVT 2

BB 8010B M-02BB02 H-6 1 C-6" RV SA C 0

RVT 2

BB 8010C M-02BB02 H-5 1 C 6"

RV SA C 0

RVT 2

l' BB HV 8000A M-02BB02 E-7 1 B 3"

GA MO O 0/C BT OP 15 6

BB HV 8000A M-02BB02 E-7 1 B 3"

GA MO O 0/C PIT RR l

BB HV 8000B M-02BB02 E-7 1 B 3"

GA M0 O 0/C BT OP 15 6

BB HV 8000B M-02BB02 E-7 1 B 3"

GA MO O 0/C PIT RR l

BB HV 8026 M-02BB02 E-3 2 A 1"

DI A0 C C

AT RR V04 10 BB HV 8026 M-02BB02 E-3 2 A 1"

DI A0 C C

BT OP 10 EB HV 8026 M-02BB02 E-3 2 A 1"

DI A0 C C

FST OP BB HV 8026 M-02BB02 E-3 2 A 1"

DI A0 C C

PIT RR l

BB HV 8027 M-02BB02 E-3 2 A 1"

DI A0 C C

AT RR V04 10

.BP HV 8027 M:-02BB02 E-3 2 A 1"

DI A0 C C

BT OP 10 BB HV 8027 M-02BB02 E-3 2 A 1"

DI A0 C C

FST OP BB EV 8027 M-02BB02 E-3 2 A 1"

DI A0 C C

PIT RR BB HV 8157A M-02BB02 E-1 3 B 1"

GL SO C C

NA 3

BB HV 8157B M-02BB02 E-1 3 B 1"

GL S0 C C

NA 3

BB PCV0455A M-02BB02 E-7 1 B 3"

GL SO C O/C BT CS 2 5

BB PCV0455A M-02BB02 E-7 1 B.

3" GL SO C O/C PIT NA BB11 BB PCV0455B M-02BB02 A-4 1 B 4"

BA A0 0 N/A NA 3

BB PCV0455C M-02BB02 B-4 1-B 4"

BA A0 0 N/A NA 3

BB PCV0456A M-02BB02 E-8 1 B'

3" GL SO C 0/C BT CS 2 5

BB PCV0456A M-02BB02 E-8 1 B 3"

GL S0 C O/C PIT NA BB11 BB V 0084 M-02BB02 C-4 1 C 2"

CK SA C C

NA 3

i

Pags 8 INSERVICE TESTING PROGRAM SY VLV-NUMBER

  • -P+ID
  • SIZE TYP AT POS DIR TST TM MAX *R/R
  • NOTES
  • BB HV 0013 M-02BB03 C-2 3 B 3"

GA M0 0 C

BT CS 30 BB-8 5,6 BB HV 0013 M-02BB03 C-2 3 B"

3" GA M0 O C

PIT RR BB HV 0014 M-02BB03 C-2 3 B 3"

GA MO O C

BT CS 30 BB-8 5,6 BB HV 0014 M-02BB03 C-2 3 B 3"

GA MO O C

PIT RR BB HV 0015 M-02BB03 C-2 3 B 3"

GA MO O C

BT CS 30 BB-8 5,6 BB HV 0015 M-02BB03 C-2 3 B 3"

GA M0 O C

PIT RR BB HV 0016 M-02BB03 C-2 3 B 3"

GA MO O C

BT CS 30 BB-8 5,6 BB HV 0016 M-02BB03 C-2 3 B 3"

GA M0 O C

PIT RR BB HV 8141A M-02BB03 E-3 2 B

.75" GL A0 0 0

NA 3

BB KV 8141B M-02BB03 E-3 2 B

.75" GL A0 0 0

NA 3

BB HV 8141C M-02BB03 E-3 2 B

.75" GL A0 0 0

NA 3

BB HV 8141D M-02BB03 E-3 2 B

.75" GL A0 0 0

NA 3

l BB HV 8351A H-02BB03 C-5 2 A 2"

GL MO O 0/C AT RR V04 10 BB HV 8351A M-02BB03 C-5 2 A 2"

GL MO O 0/C BT CS 10 BB-9 5 BB HV 8351A M-02BB03 C-5 2 A 2"

GL MO O 0/C PIT RR l

BB HV 8351B M-02BB03 C-5 2 A 2"

GL M0 O 0/C AT RR V04 10 BB HV 8351B M-02BB03 C-5 2 A 2"

GL MO O 0/C BT CS 10 BB-9 5 BB HV 8351B M-02BB03 C-5 2 A 2"

GL M0 O 0/C PIT RR l

BB HV 8351C M-02BB03 C-5 2 A 2"

GL MO O 0/C AT RR V04 10 BB HV 8351C' M-02BB03 C-5 2 A 2"

GL MO O 0/C BT CS 10 BB-9 5 BB HV 8351C M-02BB03 C-5 2 A 2"

GL MO O 0/C PIT RR l

BB HV 8351D M-02BB03 C-5 2 A 2"

GL MO O 0/C AT RR V04 10 BB HV 8351D M-02BB03 C-5 2 A 2"

GL MO O 0/C BT CS 10 BB-9 5 BB HV 8351D M-02BB03 C-5 2 A 2"

GL MO O 0/C PIT RR l

BB V 0118 M-02BB03 C-5 2 A,C 2"

CK SA 0 C

AT RR V04 10 1

BB V 0118 M-02BB03 C-5 2 A,C 2"

CK SA 0 C

CVT RR BB-7 5 BB V 0120 M-02BB03 C-4 1 C 2"

CK SA 0 0

NA BB V 0121 M-02BB03 C-4 1 C 2"

CK SA 0 0

NA BB V 0122 M-02BB03 C-4 3 C 3"

CK SA 0 0

NA 3

BB V 0124 M-02BB03 B-3 3 C

.75" RV SA C 0

RVT 2

l BB V 0148 M-02BB03 C-5 2 A,C 2"

CK SA 0 C

AT RR V04 10 l

BB V 0148 M-02BB03 C-5 2 A,C 2"

CK SA 0 C

CVT RR BB-7 5 BB V 0150 M-02BB03 C-4 1 C 2"

CK SA 0 O

NA BB V 0151 M-02BB03 C-4 1 C 2"

CK SA 0 0

NA BB V 0152 M-02BB03 C-4 3 C 3"

CK SA 0 0

NA 3

BB V 0154 M-02BB03 B-3 3 C

.75" RV SA C 0

RVT 2

l BB V 0178 M-02BB03 C-5 2 A,C 2"

CK SA 0 C

AT RR V04 10 l

BB V 0178 M-02BB03 C-5 2 A,C 2"

CK SA 0 C

CVT RR BB-7 5 BB V 0180 M-02BB03 C-4 1 C 2"

CK SA 0 0

NA BB V 0181 M-02BB03 C-4 1 C 2"

CK SA 0 0

NA BB V 0182 M-02BB03 C-4 3 C 3"

CK SA 0 0

NA 3

BB V 0184 M-02BB03 B-3 3 C'

.75" RV SA C 0

RVT 2

l BB V 0208 M-02BB03 C-5 2 A,C 2"

CK SA 0 C

AT RR V04 10 1

BB V 0208 M-02BB03 C-5 2 A,C 2"

CK SA 0 C

CVT RR BB-7 5 BB V 0210 M-02BB03 C-4 1 C 2"

CK SA 0 C

NA BB V 0211 M-02BB03 C-4 1 C 2"

CK SA 0 C

NA BB V 0212 M-02BB03 C-4 3 C 3"

CK SA 0 0

NA 3

BB V 0214 M-02BB03 B-3 3 C

.75" RV SA C 0

RVT 2

w

r--

Pag 2 10 INSERVICE TESTING PROGRAM SY VLV-NUMBER

  • -P+ID
  • SIZE TYP AT POS DIR TST TM MAX *R/R
  • NOTES
  • BG 8117 M-02BG01 H-3 2 C 2"

RV SA C 0

RVT 2

BG 8121 M-02BG01 D-3 2 C 2"

RV SA C 0

RVT 2

)

BG 8381 M-02BG01 F-4 2 A,C 3"

CK SA 0 C

AT RR V04 10 i

BG 8381 M-02BG01 F-4 2 A,C 3"

CK SA 0 C

CVT RR BG-1 5 BG HCV0123 M-02BG01 E-5 2 B 1"

GL A0 C C

NA 3

l BG HV 8100 M-02BG01 D-2 2 A 2"

GL M0 O C

AT RR V04 10 BG HV 8100 M-02BG01 D-2 2 A 2"

GL MO O C

BT CS 10 BG-2 5,6 BG HV 8100 M-02BG01 D-2 2 A 2"

GL MO O C

PIT RR l

BG HV 8112 M-02BG01 D-2 2 A 2"

GL MO O C

AT RR V04 10 BG HV 8112 M-02BG01 D-2 2 A 2"

GL MO O C

BT CS 10 BG-2 5,6 BG HV 8112 M-02BG01 D-2 2 A 2"

GL MO O C

PIT RR BG HV 8143 M-02BG01 E-3 2 B 1"

TW A0 0 0

NA 3

BG HV 8145 M-02BG01 G-7 1 B 2"

GL A0 C C

NA 3

BG HV 8146 M-02BG01 F-7 2 B 3"

GL A0 0 0

NA 3

BG HV 8147 M-02BG01 F-7 2 B 3"

GL AO O O

NA 3

l BG HV 8152 M-02BG01 F-2 2 A 3"

GL A0 0 C.

AT RR V04 10 BG HV 8152 M-02BG01 F-2 2 A 3"

GL A0 0 C

BT CS 10 BG-3 5 BG HV 8152 M-02BG01 F-2 2 A 3"

GL AO' O C

FST CS 5

BG HV 8152 M-02BG01 F-2 2 A 3"

GL A0 0 C

PIT RR BG HV 8153A M-02BG01 D-7 1 B 1"

GL SO C C

NA 3

BG HV 8153B M-02BG01 D-7 1 B 1"

GL SO C C

NA 3

BG HV 8154A M-02BG01-D-8 1 B 1"

GL SO C C

NA 3

BG HV 8154B M-02BG01 D-8 1 B 1"

GL SO C C

NA 3

l BG HV 8160 M-02BG01 F-3 2 A 3"

GL A0 0 C

AT RR V04 10 BG HV 8160 M-02BG01 F-3 2 A 3"

GL A0 0 C

BT CS 10 BG-3 5 BG HV 8160 M-02BG01 F-3 2 A 3"

GL A0 0 C

FST CS 5

BG HV 8160 M-02BG01 F-3 2 A 3"

GL A0 0 C

PIT RR BG V 0019 M-02BG01 E-7 2 C

.75" CK SA C C

NA 12 l

BG V 0135 M-02BG01 D-3 2 A,C

.75" CK SA C C

AT RR V04 9,10 BG V 0203 M-02BG01 E-7 3 C

.75" RV SA C 0

RVT RR 2

l

Pags 12 INSERVICE TESTING PROGRAM SY VLV-NUMBER

  • -P+ID
  • SIZE TYP AT POS DIR TST TM MAX *R/R
  • NOTES
  • BG 8118 M-02BG03 E-4 2 C 1.5" RV SA C 0

RVT 2

BG 8120 M-02BG03 G-8 2 C 3"

RV SA C 0

RVT 2

BG 8123 M-02BG03 H-3 2 C 2"

RV SA C 0

RVT 2

BG 8124 M-02BG03 B-7 2 C

.75" RV SA C 0

RVT 2

BG 8440 M-02BG03 E-6 2 C 4"

CK SA 0 0

NA~

3 BG 8481A M-02BG03 C-4 2 C 4"

CK SA C 0

CVT RR BG-4 5 BG 8481B M-02BG03 B-4 2 C 4"

CK SA C 0

CVT RR BG-4 5 BG 8497.

M-02BG03 E-4 2 C 3"

CK SA 0 0

NA 3

BG 8546A M-02BG03 C-7 2 C 8"

CK SA C 0

CVT RR BG-5 5 BG 8546B M-02BG03 B-7 2 C 8"

CK SA C 0

CVT RR BG-5 5 BG FCV0111B M-02BG03 G-5 2 B 2"

DI A0 C C

NA 3

BG FCV0121 M-02BG03 D-4 2 B 3"

GL A0 0 0

NA 3

BG HCV0182 M-02BG03 E-3 2 B 3"

GL A0 0 0

NA 3

l BG HV 8105 M-02BG03 E-2 2 A 3"

GA MO O C

AT RR V04 10 BG HV 8105 M-02BG03 E-2 2 A 3"

GA M0 O C

BT CS 10 BG-6 6,5 BG HV 8105 M-02BG03 E-2 2 A 3"

GA MO O C

PIT RR BG HV 8106 M-02BG03 E-2 2 B 3"

GA MO O C

BT CS 10 BG-6 6,5 BG HV 8106 M-02BG03 E-2 2 B 3"

GA MO O C

PIT RR BG HV 8109 M-02BG03 E-5 2 B 2"

GL MO C C

NA 12 BG HV 8110 M-02BG03 E-3 2 B 2"

GL MO O 0/C BT OP 10 6

BG HV 8110 M-02BG03 E-3 2 B 2"

GL MO O 0/C PIT RR BG HV 8111 M-02BG03 E-4 2 B 2"

GL MO O 0/C BT OP 10 6

BG HV 8111 M-02BG03 E-4 2 B 2"

GL M0 O 0/C PIT RR BG HV 8357A M-02BG03 C-4 2 B 1"

GL S0 C O/C BT OP 10 BG-8 l BG HV 8357B M-02BG03 B-4 2 B 1"

GL SO C O/C BT OP 15 BG-8 BG LCV0112B M-02BG03 F-6 2 B 4"

GA MO O C

BT CS 10 BG-7 5,6 BG LCV0112B M-02BG03 F-6 2 B 4"

GA MO O C

PIT RR BG LCV0112C M-02BG03 F-6 2 B 4"

GA MO O C

BT CS 10 BG-7 5,6 BG LCV0112C M-02BG03 F-6 2 B 4"

GA MO O C

PIT RR BG V 0091 M-02BG03 C-4 2 C 2"

CK SA C 0

CVT OP BG V 0095 M-02BG03 B-4 2 C 2"

CK SA C 0

CVT OP BG V 0207 M-02BG03 G-4 3 B 3"

RV SA C' O

RVT RR 2

BG V 0524 M-02BG03 C-6 3 C

.75" RV SA C 0

RVT 2

BG V 0525 M-02BG03 A-6 3 C

.75" RV SA C 0

RVT 2

i BG V 0545 M-02BG03 D-5 3 C

.75" RV SA C 0

RVT 2

BG V 0589 M-02BG03 B-4 2 C 1"

CK SA C C

NA 3

BG V 0590 M-02BG03 C-4 2 C 1"

CK SA C C

NA 3

l 1

4

Pag 2 15 INSERVICE TESTING PROGRAM SY VLV-NUMBER

  • -P+ID
  • SIZE TYP AT POS DIR TST TM MAX *R/R
  • NOTES
  • l BL 8046 M-02BLOL B-3 2 A,C 3"

CK SA 0 C

AT RR V04 10 l

BL 8046 M-02BL01 B-3 2 A,C 3"

CK SA 0 C

CVT RR BL-1 11 l

BL HV 8047 M-02BL01 B-4 2 A 3"

DI A0 0 C

AT RR V04 10 BL HV 8047 M-02BL01 B-4 2 A 3"

DI A0 0 C

BT OP 10 BL HV 8047 M-02BL01 B-4 2 A 3"

DI A0 0 C

FST OP BL HV 8047 M-02BL01 B-4 2 A 3"

DI A0 0 C

PIT RR

m Pege 16 INSERVICE TESTING PROGRAM SY VLV-NUMBER

  • -P+ID
  • SIZE TYP AT POS DIR TST TM MAX *R/R
  • NOTES
  • BM HV 0001 M-02BM01 F-5 2 B 4"

GL A0 0 C

BT CS 10 BM-1 5 BM HV 0001 M-02BM01 F-5 2 B 4"

GL A0 0 C

FST CS BM-1 5 BM HV 0001 M-02BM01 F-5 2 B 4"

GL A0 0 C

PIT RR BM HV 0002 M-02BM01 E-5 2 B 4"

GL A0 0 C

BT CS 10 BM-1 5 BM HV 0002 M-02BM01 E-5 2 B 4"

GL A0 0 C

FST CS BM-1 5 BM HV 0002 M-02BM01 E-5 2 B 4"

GL A0 0 C

PIT RR BM HV 0003 M-02BM01 C-5 2 B 4"

GL A0 0 C

BT CS 10 BM-1 BM HV 0003 M-02BM01 C-5 2 B 4"

GL A0 0 C

FST CS 5

BM HV 0003 M-02BM01 C-5 2 B 4"

GL A0 0 C

PIT RR BM HV 0004 M-02BM01 A-5 2 B 4"

GL A0 0 C

BT CS 10 BM-1.

BM HV 0004 M-02BM01 A-5 2 B 4"

GL A0 0 C

FST CS 5

BM HV 0004 M-02BM01 A-5 2 B 4"

GL A0 0 C

PIT RR BM HV 0019 M-02BM01 G-7 2 B 1"

GL SO C C.

BT OP 5 BM HV 0019 M-02BM01 G-7 2 B 1"

GL SO C C

FST OP BM HV 0019 M-02BM01 G-7 2 B 1"

GL SO C C

PIT NA BM-2 BM HV 0020 M-02BM01 E-7 2 B 1"

GL SO C C

BT OP 5 BM HV 0020 M-02BM01 E-7 2 B 1"

GL SO C C

FST OP BM HV 0020 M-02BM01 E-7 2 B 1"

GL SO C C

PIT NA BM-2 BM HV 0021 M-02BM01 D-7 2 B 1"

GL' SO C C

BT OP 5 BM HV 0021 M-02BM01 D-7 2 B 1"

GL SO C C

FST OP BM HV 0021 M-02BM01 D-7 2 B 1"

GL SO C C

PIT NA BM-2 BM HV 0022 M-02BM01 B-7 2 B 1"

GL SO C C

BT OP S

~BM HV 0022 M-02BM01 B-7 2 B 1"

GL SO C C

FST OP BM HV 0022 M-02BM01 B-7 2 B 1"

GL SO C C

PIT NA BM-2 BM HV 0035 M-02BM01 G-7 2 B 1"

GL SO O C

BT OP 5 BM HV 0035 M-02BM01 G-7 2 B 1"

GL SO O C

FST OP BM HV 0035 M-02BM01 G-7 2 B 1"

GL SO O C

PIT NA BM-2 BM HV 0036 M-02BM01 E-7 2 B 1"

GL SO O C

BT OP 5 HM HV 0036 M-02BM01 E-7 2 B 1"

GL SO O C

FST OP BM HV 0036 M-02BM01 E-7 2 B 1"

GL SO O C

PIT NA BM-2 BM HV 0037 M-02BM01 C-7 2 B 1"

GL SO O C

BT OP 5 BM HV 0037 M-02BM01 C-7 2 B 1"

GL SO O C

FST OP BM HV 0037 M-02BM01 C-7 2 B 1"

GL SO O C

PIT NA BM-2 l

BM HV 0038 M-02BM01 B-7 2 B 1"

GL SO O C

BT OP 5 BM HV 0038 M-02BM01 B-7 2 B 1"

GL SO O C

FST OP BM HV 0038 M-02BM01 B-7 2 B 1"

GL SO O C

PIT NA BM-2 BM HV 0065 M-02BM01 G-6 2 B 1"

GL SO O C

BT -OP 5 BM HV 0065 M-02BM01 G-6 2 B 1"

GL SO O C

FST OP HM HV 0065 M-02BM01 G-6 2 B 1"

GL SO O C

PIT NA BM-2 BM HV 0066 M-02BM01 E-6 2 B 1"

GL SO O C

BT OP 5 BM HV 0066 M-02BM01 E-6 2 B 1"

GL SO O C

FST OP i

l BM HV 0066 M-02BM01 E-6 2 B 1"

GL SO O C

PIT NA BM-2 i

BM HV 0067 M-02BM01 C-6 2 B 1"

GL SO O C

BT OP 5 l

BM HV 0067 M-02BM01 C-6 2 B 1"

GL SO O C

FST OP l

BM HV 0067 M-02BM01 C-6 2 B 1"

GL SO O C

PIT NA BM-2 l

BM HV 0068 M-02BM01 B-6 2 B 1"

GL SO O C

BT OP 5 l

BM HV 0068 M-02BM01 B-6 2 B 1"

GL SO O C

FST OP BM HV 0068 M-02BM01 B-6 2 B 1"

GL ' SO O C

PIT NA BM-2 l

BM V 0045 M-02BM01 A-4 2 A 3"

GA M C C

AT RR V04 1,9,11 1

BM V 0046 M-02BM01 A-3 2 A 3"

GA M C C

AT RR V04 1,9,11 i

Paga 17 INSERVICE TESTING PROGRAM SY VLV-NUMBER

  • -P+ID
  • SIZE TYP AT POS DIR TST TM MAX *R/R
  • NOTES
  • BN HCV8800A M-02BN01 E-5 2 B 3"

GL A0 C C

NA 3

BN HCV8800B M-02BN01 E-5 2 B 3"

GL A0 C C

NA 3

BN HV 0003 M-02BN01 C-3 2 B 12" GA MO O C

BT OP 65 6

BN HV 0003 M-02BN01 C-3 2 B 12" GA MO O C

PIT RR BN HV 0004 M-02BN01 A-3 2 B 12" GA MO O C

BT OP 65 6

BN HV 0004 M-02BN01 A-3 2 B 12" GA MO O C

PIT RR I

JN HV 8806A M-02BN01 B-5 2 B 8"

GA MO O C

BT OP 15 6

BN HV 8806A M-02BN01 B-5 2 B 8"

GA hu O C

PIT RR I

BN HV-8806B M-02BN01 E-3 2 B 8"

GA MO O C

BT OP 15 6

BN HV 8806B M-02BN01 E-3 2 B 8"

GA MO O C

PIT RR BN HV 8812A M-02BN01 B-3 2 B 14" GA MO O C

BT OP 17 6

BN HV 8812A M-02BN01 B-3 2 B 14" GA MO O C

PIT RR BN HV 8812B M-02BN01 D-3 2 B 14" GA MO O C

BT OP 17 6

BN HV 8812B M-02BN01 D-3 2 B 14" GA MO O C

PIT RR BN HV 8813 M-02BN01 B-7 2 B 2"

GL MO O C

BT CS 10 BN-2 6,5 BN HV 8813 M-02BN01 B-7 2 B 2"

GL MO O C

PIT RR BN LCV0112D M-02BN01 A-5 2 B 8"

GA M0 C O/C BT CS 10 BN-1 6,5 BN LCV0112D M-02BN01 A-5 2 B 8"

GA M0 C O/C PIT RR BN LCV0112E M-02BN01 E-3 2 B 8"

GA M0 C O/C BT CS 10 BN-1 6,5 BN LCV0112E M-02BN01 E-3 2 B 8"

GA M0 C O/C PIT RR l

l l _

l

Pago 19 INSERVICE TESTING PROGRAM SY VLV-NUMBER

  • -P+ID
  • SIZE TYP AT POS DIR TST TM MAX *R/R
  • NOTES
  • l EC V 0083 M-02EC02 C-6 2 A 6"

GA M C C

AT RR V04 1,9,11 l

EC V 0084 M-02EC02 C-5 2 A 6"

GA M.

C C

AT RR V04 1,9,11 l

EC V 0087 M-02EC02 D-7 2 A 6"

GA M.C C

AT RR V04 1,9,11 1

EC V 0088 M-02EC02 D-7 2 A 6"

GA M C C

AT RR V04 1,9,11 l

EC V 0095 M-02EC02 B-5 2 A 6"

GA M C C

AT RR V04 1,9,11 l

EC V 0096 M-02EC02 B-5 2 A 6"

GA M C C

AT RR V04 l',9,11 r

Paga 21 INSERVICE TESTING PROGRAM SY VLV-NUMBER

  • -P+ID
  • SIZE TYP AT POS DIR TST TM MAX *R/R
  • NOTES
  • l EF HV 0031 M-02EF02 G-7 2 A 14" BT MO O 0/C AT RR V04 10 1

EF HV 0031 M-02EF02 G-7 2 A 14" BT MO O 0/C BT OP 40 6

EF HV 0031 M-02EF02 G-7 2 A 14",

BT MO O 0/C PIT RR l

EF HV 0032

-M-02EF02 B-7 2 A 14" BT MO O 0/C AT RR V04 10 l

EF HV 0032 M-02EF02 B-7 2 A 14" BT MO O 0/C BT OP 40 6

EF HV 0032 M-02EF02 B-7 2 A 14" BT MO O 0/C PIT RR l

EF HV 0033

.M-02EF02 G-7 2 A 14" BT MO O 0/C AT RR V04 10 1

EF HV 0033 M-02EF02 G-7 2 A 14" BT MO O 0/C BT OP 40 6

EF HV 0033 M-02EF02 G-7 2 A 14" BT MO O 0/C PIT RR I

EF HV 0034 M-02EF02 B-7 2 A 14" BT MO 0.

0/C AT RR V04 10 6

1 EF HV 0034 M-02EF02 B-7 2 A 14" BT MO O 0/C BT OP 35 EF HV 0034 M-02EF02 B-7 2 A 14" BT MO O 0/C PIT RR EF HV 0037 M-02EF02 G-2 3 B 30" BT M0 C 0

BT OP 30 6

EF HV 0037 M-02EF02 G-2 3 B 30" BT M0 C 0

PIT RR EF HV 0038 M-02EF02 C-2 3 B 30" BT MO C 0

BT OP 30 6

EF HV 0038 M-02EF02 C-2 3 B 30" BT Mo C 0

PIT RR EF HV 0039 M-02EF02 F-2 3 B 30" BT MO O C

BT OP 30 6

EF HV 0039 M-02EF02 F-2 3 B 30" BT MO O C

PIT RR EF HV 0040 M-02EF02 D-2 3 B 30" BT MO O C

BT OP 30 6

EF HV 0040 M-02EF02 D-2 3 B 30" BT MO O C

PIT RR EF HV 0041 M-02EF02 E-2 3 B 30" BT MO O C

BT OP 30 6

EF HV 0041 M-02EF02 E-2 3 B 30" BT MO O C

PIT RR EF HV 0042 M-02EF02 D-2 3 B'

30"-

BT MO O C

BT OP 30 6

EF HV 0042 M-02EF02 D-2 3 B 30" BT MO O C

PIT RR l

EF HV 0043 M-02EF02 E-7 3 B 2"

GL A0 0 C

BT OP 8 EF HV 0043 M-02EF02 E-7 3 B 2"

GL A0 0 C

FST OP EF HV 0043 M-02EF02 E-7 3 B 2"

GL A0 0 C

PIT RR l

EF HV 0045 M-02EF02 G-6 2 A 14" BT M0 O 0/C AT RR V04 10

-l EF HV 0045 M-02EF02 G-6 2 A 14" BT MO O 0/C BT OP 40 6

EF HV 0045 M-02EF02 G-6 2 A 14" BT MO O 0/C PIT RR l

EF HV 0046 M-02EF02 B-6 2 A 14" BT M0 O 0/C AT RR V04 10 l

EF HV 0046 M-02EF02 B-6 2 A 14" BT MO O 0/C BT OP 35 6

EF HV 0046 M-02EF02 B-6 2 A 14" BT MO O 0/C PIT RR l

'l EF HV 0047 M-02EF02 G-6 2 A 10" BT MO O C

AT RR V04 10 EF HV 0047 M-02EF02 G-6 2 A 10" BT M0 O C

BT OF 30 6

EF HV 0047 M-02EF02 G-6 2 A 10" BT MO O C

PIT RR i

EF HV 0048 M-02EF02 C-6 2 A 10" BT M0 0 C

AT RR V04 10 EF HV 0048 M-02EF02 C-6 2 A 10" BT MO O C

BT OP 30 6

i EF HV 0048 M-02EF02 C-6 2 A 10" BT MO O C

PIT RR

[

l EF HV 0049 M-02EF02 G-6 2 A 14" BT M0 C O/C AT RR V04 10 EF HV 0049 M-02EF02 G-6 2 A.

14" BT M0 C O/C BT OP 30 6

EF HV 0049 M-02EF02 G-6 2 A 14" BT MO C O/C PIT RR

~

I EF HV 0050 M-02EF02 B-6 2 A 14" BT M0 C O/C AT RR V04 10 EF HV 0050 M-02EF02 B-6 2 A 14" BT M0 C O/C BT OP 30 6

EF HV 0050 M-02EF02 B-6 2 A 14" BT M0 C 0/C PIT RR l

l EF HV 0051 M-02EF02 G-4 3 B 24" BT MO O O

BT OP 65 6

EF HV 0051 M-02EF02 G-4 3 B 24" BT M0 0 0

PIT RR i

EF HV 0052 M-02EF02 C-4 3 B 24" BT MO O O

BT OP 60 6

l' EF HV 0052 M-02EF02 C-4 3 B 24" BT MO O O

PIT RR I

EF HV 0059 M-02EF02 G-3 3 B 24" BT MO O C

BT OP 65 6

EF HV 0059 M-02EF02 G-3 3 B 24" BT MO O C

PIT RR l

EF HV 0060 M-02EF02 C-3 3 B 24" BT MO O C

BT OP 65 6

l

Psgs 25 INSERVICE TESTING PROGRAM SY VLV-NUMBER

  • -P+ID
  • SIZE TYP AT POS DIR TST TM MAX *R/R
  • NOTES
  • l EG HV 0058 M-02EG03 H-5 2 A 12" GA MO O C

AT RR V04. 10 EG HV 0058 M-02EG03 H-5 2 A 12" GA MO O C

BT OP 30 6

EG HV 0058 M-02EG03 H-5 2 A 12" GA MO O C

PIT RR l

EG HV 0059 M-02EG03 C-5 2 A 12" GA MO O C

AT RR V04 10 EG HV 0059 M-02EG03 C-5 2 A 12" GA MO O C

BT OP 30 6

EG HV 0059 M-02EG03 C-5 2 A 12" GA MO O C

PIT RR l

EG HV 0060 M-02EG03 B-5 2 A 12" GA MO O C

AT RR V04 10 EG HV 0060 M-02EG03 B-5 2 A 12" GA MO O C

BT OP 30 6

EG HV 0060 M-02EG03 B-5 2 A 12" GA MO O C

PIT RR 3

EG HV 0061 M-02EG03 C-4 2 A 4"

GA MO O C

AT RR V04 10 EG HV 0061 M-02EG03 C-4 2 A 4"

GA MO O C

BT OP 30 6

EG HV 0061 M-02EG03 C-4 2 A 4"

GA MO O C

PIT RR I

EG HV 0062 M-02EG03 B-4 2 A 4"

GA MO O C

AT RR V04 10 EG HV 0062 M-02EG03 B-4 2 A 4"

GA MO O C

BT OP 30 6

EG HV 0062 M-02EG03 B-4 2 A 4"

GA MO O C

PIT RR l

EG HV 0069A M-02EG03 F-8 3 B 14" BT A0 0 C

BT OP 13 EG HV 0069A M-02EG03 F-8 3 B 14" BT A0 0 C

FST OP EG HV 0069A M-02EG03 F-8 3 B 14" BT A0 0 C

PIT RR l

EG HV 0069B M-02EG03 F-6 3 B 14" BT A0 0 C

BT OP 13 EG HV 0069B M-02EG03 F-6 3 B 14" BT A0 0 C

FST OP EG HV 0069B M-02EG03 F-6 3 B 14" BT A0 0 C

PIT RR l

EG HV 0070A M-02EG03 F-8 3 B 14" BT A0 0 C

BT OP 10 EG HV 0070A M-02EG03 F-8 3 B 14" BT A0 0 C

FST OP EG HV 0070A M-02EG03 F-8 3 B 14" BT A0 0 C

PIT RR l

EG HV 0070B M-02EG03 F-6 3 B 14" BT A0 0 C

BT OP 10 EG HV 0070B M-02EG03 F-6 3 B 14" BT A0 0 C

FST OP EG HV 0070B M-02EG03 F-6 3 B 14" BT A0 0 C

PIT RR EG HV 0071 M-02EG03 H-5 3 B 12" GA MO O C

BT OP 30 6

EG HV 0071 M-02EG03 H-5 3 B 12" GA MO O C

PIT RR EG HV 0126 M-02EG03 G-5 3 B 12" GA M0 C 0

BT OP 30 EG HV 0126 M-02EG03 G-5 3 B 12" GA MO C 0

PIT RR l

EG HV 0127 M-02EG03 G-5 2 A 12" GA M0 C 0

AT RR V04 10 EG HV 0127 M-02EG03 G-5 2 A 12" GA MO C 0

BT OP 30 EG HV 0127 M-02EG03 G-5 2 A 12" GA M0 C 0

PIT RR l

EG HV 0130 M-02EG03 B-5 2 A 12" GA MO C ~ 0 AT RR V04 10 EG HV 0130 M-02EG03 B-5 2 A 12" GA M0 C 0

BT OP 30 EG HV 0130 M-02EG03 B-5 2 A 12" GA M0 C 0

PIT RR l

EG HV 0131 M-02EG03 C-5 2 A 12" GA M0 C 0

AT RR V04 10 EG HV 0131 M-02EG03 C-5 2 A 12" GA M0 C 0

BT OP 30 EG HV 0131 M-02EG03 C-5 2 A 12" GA M0 C 0

PIT RR l

EG HV 0132 M-02EG03 B-4 2 A 4"

GA M0 C 0

AT RR V04 10 EG HV 0132 M-02EG03 B-4 2 A 4"

GA M0 C 0

BT OP 30 EG HV 0132 M-02EG03 B-4 2 A 4"

GA M0 C 0

PIT RR I

EG HV 0133 M-02EG03 C-5 2 A 4"

GA M0 C 0

AT RR V04 10 EG HV 0133 M-02EG03 C-5 2 A 4"

GA M0 C 0

BT OP 30 EG HV 0133 M-02EG03 C-5 2 A 4"

GA M0 C 0

PIT RR EG V 0124 M-02EG03 D-4 3 C 4"

CK SA 0 0

NA 3

EG V 0129 M-02EG03 D-5 3 C 12" CK SA 0 0

NA 3

l EG V 0204 M-02EG03 H-4 2 A,C 12" CK SA 0 0/C AT RR V04 10 EG V 0204 M-02EG03 H-4 2 A,C 12" CK SA 0 0/C CVT OP EG-1

Pcgs 26 INSERVICE TESTING PROGRAM SY VLV-NUMBER

  • -P+ID
  • SIZE TYP AT POS DIR TST TM MAX *R/R
  • NOTES
  • EJ 8708A M-02EJ01 F-7 2 C 3"

RV SA C O/C RVT 2

s EJ 8708B M-02EJ01 C-7 2 C 3"

RV SA C O/C RVT 2

EJ 8730A M-02EJ01 G-4 2 C 10" CK SA C 0

CVT OP EJ 8730B M-02EJ01 C-4 2 C 10" CK SA C 0

CVT OP l

EJ 8841A M-02EJ01 E-2 1 A,C 6"

CK SA C C/0 AT -CS V05 5,7 EJ 8841A M-02EJ01 E-2 1 A,C 6"

CK SA C C/0 CVT CS,

EJ-1 l

EJ 8841B M-02EJ01 D-2 1 A,C 6"

CK SA C C/0 AT CS V05 5,7 EJ 8841B H-02EJ01 D-2 1 A,C 6"

CK SA C C/0 CVT CS EJ-1 EJ 8958A M-02EJ01 F-6 2 C 14" CK SA C 0

CVT OP EJ 8958B M-02EJ01 B-6 2 C 14" CK SA C 0

CVT OP EJ 8969A M-02EJ01 G-3 2 C 8"

CK SA C 0

CVT RR l'J-2 5 EJ 8969B M-02EJ01 A-4 2 C 8"

CK sA C 0

CVT RR EJ-2 5 l

EJ FCV0610 M-02EJ01 H-6 2 B 3"

GA MO O C

BT OP 13 6

1 EJ FCV0610 M-02EJ01 H-6 2 B 3"

GA MO O C

PIT RR EJ FCV0611 M-02EJ01 A-5 2 B 3"

GA MO O C

BT OP 10 6

l EJ FCV0611 M-02EJ01 A-5 2 B 3"

GA MO O C

PIT RR EJ FCV0618 M-02EJ01 F-5 2 B 8"

BT A0 C C

NA 3

EJ FCV0619 M-02EJ01 B-5 2 B 8"

BT A0 C C

NA 3

EJ HCV0606 M-02EJ01 G-4 2 B 10" BT A0 0 0

NA 3

EJ HCV0607 M-02EJ01 C-4 2 B 10" BT A0 0 0

NA 3

EJ HCV8825' M-02EJ01 E-2 2 B

.75" GL A0 C C

BT OP 10 EJ HCV8825~

M-02EJ01 E-2 2 B

.75" GL A0 C C

PIT RR EJ HCV8890A M-02EJ01 F-2 2 B

.75" GL A0 C C

BT OP 13 EJ HCV8890A M-02EJ01 F-2 2 B

.75" GL A0 C C

PIT RR EJ HCV8890B M-02EJ01 C-2 2 B

.75" GL A0 C C

BT OP 13 EJ HCV88908 M-02EJ01 C-2 2 B

.75" GL A0 C C

PIT RR i

EJ HV 0014 M-02EJ01 H-5 2 B 1"

GL SO C C

NA 3

EJ HV 0015 M-02EJ01 A-5 2 B 1"

GL SO C C

NA 3

EJ HV 0021 M-02EJ01 E-7 2 B 1"

GL SO C 0

BT OP 5 l

EJ HV 0022 M-02EJ01 D-7 2 B 1"

GL SO C 0

BT OP 5 l

EJ HV 0023 M-02EJ01 E-7 2 A 1"

GL SO C O/C AT RR V04 10 EJ HV 0023 M-02EJ01 E-7 2 A'

1" GL SO C O/C BT OP 5 l

EJ HV 0024 M-02EJ01 D-6 2 A 1"

GL SO C O/C AT RR V04 10 EJ HV 0024 M-02EJ01 D-6 2 A 1"

GL SO C O/C BT OP 5 l

EJ HV 0025 M-02EJ01 E-7 2 A 1"

GL SO C O/C AT RR V04 10 EJ HV 0025 M-02EJ01 E-7 2 A 1"

GL SO C O/C BT OP 5 l

EJ HV 0026 M-02EJ01 D-6 2 A 1"

GL SO C O/C AT RR V04 10 EJ HV 0026 M-02EJ01 D-6 2 A 1"

GL SO C O/C BT OP 5 l

EJ HV 8701A M-02EJ01 F-8 1 A 12" GA M0 C C

AT CS V05 7 EJ HV 8701A M-02EJ01 F-8 1 A 12" GA MO C C

BT CS 120 EJ-3 5,6 EJ HV 8701A M-02EJ01 F-8 1 A 12" GA M0 C C

PIT RR 1

EJ HV 8701B M-02EJ01 B-8 1 A 12" GA M0 C C

AT CS V05 7 EJ HV 8701B M-02EJ01 B-8 1 A 12" GA MO C C

BT CS 120 EJ-3 5,6 EJ HV 8701B M-02EJ01 B-8 1 A 12" GA M0 C C

PIT RR l

EJ HV 8716A M-02EJ01 E-4 2 B 10" GA MO O C

BT OP 15 6

EJ HV 8716A

'M-02EJ01 E-4 2 B 10" GA MO O C

PIT RR I

EJ HV 8716B M-02EJ01 D-4 2 B 10" GA MO O C

BT OP 15 6

EJ HV 8716B M-02EJ01 D-4 2 B 10" GA MO O C

PIT RR I

EJ HV 8804A M-02EJ01 G-4 2 B 8"

GA MO C 0

BT CS 15 EJ-4 6,5 EJ HV 8804A M-02EJ01 G-4 2 B 8"

GA MO C 0

PIT RR I

EJ HV 8804B M-02EJ01 A-4 2 3 8"

GA MO C 0

BT CS 15 EJ-4 6,5 EJ HV 8804B M-02EJ01 A-4 2 B 8"

GA M0 C 0

PIT RR

Paga 27 INSERVICE TESTING PROGRAM SY VLV-NUMBER

  • -P+ID
  • SIZE TYP AT POS DIR TST TM MAX *R/R
  • NOTES
  • l EJ HV 8809A M-02EJ01 G-3 2 B 10" GA MO O C

BT CS 15 EJ-5 6,5 EJ HV 8809A M-02EJ01 G-3 2 B 10" GA MO O C

PIT RR I

EJ HV 8809B M-02EJ01 C-3 2 B 10" GA MO O C

BT CS 15 EJ-5 6,5 EJ HV 8809B M-02EJ01 C-3 2 B 10" GA MO O C

PIT RR EJ HV 8811A M-02EJ01 E-7 2 B 14" GA M0 C O/C BT RR 18 EJ-6 6,5 EJ HV 8811A M-02EJ01 E-7 2 B 14" GA MO C O/C PIT RR EJ HV 8811B M-02EJ01 D-7 2 B 14" GA MO C O/C BT RR 18 EJ-6 6,5 EJ HV 8811B M-02EJ01 D-7 2 B 14" GA M0 C O/C PIT RR l

EJ HV 8840 M-02EJ01 E-3 2 B 10" GA M0 C 0

BT CS 15 6,5 EJ HV 8840 M-02EJ01 E-3 2 B 10" GA MO C 0

PIT RR EJ V 0084 M-02EJ01 H-5 3 C 1.5" RV SA C 0

RVT RR 2

EJ V 0085 M-02EJ01 E-5 3 C 1.5" RV SA C 0

RVT RR 2

EJ V 0156 M-02EJ01 G-5 3 C

.75" RV SA C 0

RVT RR 2

EJ V 0157 M-02EJ01 D-6 3 C

.75" RV SA C 0

RVT RR 2

d e

=

e

--my m

Pags 28

' INSERVICE TESTING PROGRAM SY VLV-NUMBER

  • -P+ID
  • SIZE TYP AT POS DIR TST TM MAX *R/R
  • NOTES
  • i EM 8922A M-02EM01 E-5 2 C 4"

CK SA C 0

CVT RR EM-1 5 EM 8922B M-02EM01 D-5 2 C 4"

CK SA C 0

CVT RR EM-1 5 EM 8926A M-02EM01 E-7 2 C 8"

CK SA C 0

CVP OP EM-5 EM 8926A M-02EM01 E-7 2 C 8"

CK SA C 0

CVT RR EM-5 EM 8926B-M-02EM01 D-7 2 C 8"

CK SA C 0

CVP OP EM-5 EM 8926B M-02EM01 D-7 2 C 8"

CK SA C 0

CVT RR EM-5 EM HV 8802A M-02EM01 E-4 2 B 4"

GA MO C 0-BT OP 10 6

EM HV 8802A M-02EM01 E-4 2 B 4"

GA M0 C 0

PIT RR EM HV 8802B M-02EM01 D-4 2 B 4"

GA MO C 0

BT OP 10 5,6 EM HV 8802B M-02EM01 D-4 2 B 4"

GA MO C 0

PIT RR EH HV 8807A M-02EM01 G-7 2 B 6"

GA MO C 0

BT OP 15 6

EM HV 8807A M-02EM01 G-7 2 B 6"

GA M0 C 0

PIT RR EM HV 8807B M-02EM01 F-7 2 B 6"

GA M0 C 0

BT OP 15 6

EM HV 88L7B M-02EM01 F-7 2 B 6"

GA M0 C 0

PIT RR EM HV 8814A' M-02EM01 B-6 2 B 1.5" 'GL MO O C

BT OP 10 6

EM HV 8814A M-02EM01 B-6 2 B 1.5" GL MO O C

PIT RR EM HV 8814B M-02EM01 B-5 2 B 1.5" GL MO O C

BT OP 10 6

EM HV 8814B M-02EM01 B-5 2 B 1.5" GL MO O C

PIT RR l

EM HV 8821A M-02EM01 E-4 2 B 4"

GA M0'O C

BT OP 15 6

EM HV 8821A M-02EM01 E-4 2 B 4"

GA M0 O C

PIT RR l

EM HV 8821B M-02EM01 D-4 2 B 4"

GA MO O C

BT OP 15 6

EM HV 8821B M-02EM01 D-4 2 B 4"

GA MO O C

PIT RR EM HV 8823 M-02EM01 C-4 2 B

.75" GL A0 C C

BT OP 10 EM HV 8823 M-02EM01 C-4 2 B

.75" GL A0 C C

FST OP EM HV 8823 M-02EM01 C-4 2 B

.75" GL A0 C C

PIT RR EM HV 8824 M-02EM01 D-3 2 B

.75" GL A0 C C

BT OP 10 EM HV 8824 M-02EM01 D-3 2 B

.75" GL A0 C C

FST OP EM HV 8824 M-02EM01 D-3 2 B

.75" GL A0 C C

PIT RR EM HV 8835 M-02EM01 B-4 2 B 4"

GA MO O C

BT CS 10 6,5 EM HV 8835 M-02EM01 B-4 2 B 4"

. GA MO O C

PIT RR I

EM HV 8871 M-02EM01 G-5 2 A

.75" GL A0 C C

AT RR V04 10 EM HV 8871 M-02EM01 G-5 2 A

.75" GL A0 C C

BT OP 10 EM HV 8871 M-02EM01 G-5 2 A

.75" GL A0 C C

FST OP I

EM HV 8871 M-02EM01 G-5 2 A

.75" GL A0 C C

PIT RR EM HV 8881 M-02EM01 G-4 2 B

.75" GL A0 C C

BT OP 10 l

EM HV 8881 M-02EM01 G-4 2 B

.75" GL A0 C C

FST OP EM HV 8881 M-02EM01 G-4 2 B

.75" GL A0 C C

PIT RR l

l EM HV 8888 M-02EM01 F-6 2 A 1"

GL A0 C C

AT RR

'V04 9,10 EM HV 8889A M-02EM01 G-2 1 B

.75" GL A0 C C

NA 3

EM HV 8889B M-02EM01 G-3 1 B

.75" GL A0 C C

NA 3

EM HV 8889C M-02EM01 G-2 1 B

.75" GL A0 C C

NA 3

EM HV 8889D M-02EM01 G-2 1 B

.75" GL A0 C C

NA 3

EM HV 8923A M-02EM01 E-7 2 B 6"

GA MO O O

NA 3

EM HV 8923B M-02EM01 D-7 2 B 6"

GA MO O O

NA 3

EM HV 8924 M-02EM01 G-8 2 B 6"

GA M0 O O

NA 3

.l EM HV 8964 M-02EM01 G-6 2 A

.75" GL A0 C C

AT RR V04 10 EM HV 8964 M-02EM01 G-6 2 A

.75" GL A0 C C

BT OP 10 EM HV 8964 M-02EM01 G-6 2 A

.75" GL A0 C C

FST OP EM HV 8964 M-02EM01 G-6 2 A

.75" GL A0 C C

PIT RR l

EM V 0001 M-02EM01 F-3 1 A,C 2"

CK SA C O/C AT CS V05 7 EM V 0001 M-02EM01 F-3 1 A.C.

2" CK SA C O/C CVT RR EM-2 5 l

EM V 0002 M-02EM01 E-3 1 A,C 2"

CK SA C O/C AT CS V05 7 l

l l

1 i

Psgs 29 INSERVICE TESTING PROGRAM SY VLV-NUMBER

  • -P+ID
  • SIZE TYP AT POS DIR TST TM MAX *R/R
  • NOTES
  • EM V 0002 M-02EM01 E-3 1 A,C 2"

CK. SA C O/C CVT RR EM-2 5 l

EM V 0003 M-02EM01 D-3 1 A,C 2"

CK SA C O/C AT CS V05 7 EM V 0003 M-02EM01 D-3 1 A,C 2"

CK SA C O/C CVT RR EM-2 5 l

EM V 0004 M-02EM01 C-3 1 A,C 2"

CK SA C O/C AT CS V05 7 EM V 0004 M-02EM01 C-3 1 A,C 2"

CK SA C O/C CVT RR EM-2 5 EM V 0005 M-02EM01 A-6 2 C 1.5" CK SA C 0

CVT OP l

EM V 0006 M-02EM01 F-6 2 A,C 1"

CK SA C C

AT RR V04 9,10 EM V 0007 M-02EM01 A-5 2 C 1.5" CK SA C 0

CVT OP EM V 0188 M-02EM01 D-6 3 C

.75" RV SA C 0

RVT RR 2

EM V 0189 M-02EM01 F-6 3 C

.75" RV SA C 0

RVT RR 2

4 4

Pago 30 INSERVICE TESTING PROGRAM SY VLV-NUMBER

  • -P+ID
  • SIZE TYP AT POS DIR TST TM MAX *R/R
  • NOTES
  • l EM 8815 M-02EM02 D-3 1 A,C 3"

CK SA C O/C AT CS V05 7 EM 8815 M-02EM02 D-3 1 A,C 3"

CK SA C O/C CVT RR EM-3 5 EM 8852 M-02EM02 E-5 3 C

.75" RV SA C 0

RVT RR 2

l EM HV 8801A M-02EM02 D-4 2' B 4"

GA M0 C 0

BT OP 15 6

EM HV 8801A M-02EM02 D-4 2 B 4"

GA MO C 0

PIT RR I

EM HV 8801B M-02EM02 D-4 2 B 4"

GA MO C 0

BT. OP 15 6

EM HV 8801B M-02EM02 D-4 2 B 4"

GA M0 C 0

PIT RR l

EM HV 8803A M-02EM02 C-7 2 B 4"

GA MO C 0

BT OP 15 6

EM HV 8803A M-02EM02 C-7 2 B 4"

GA M0 C 0

PIT RR I

EM HV 8803B M-02EM02 A-7 2 B 4"

GA M0 C 0

BT OP 15 6

EM HV 8803B M-02EM02 A-7 2 B 4"

GA MO C 0

PIT RR EN HV 8837A M-02EM02 C-7 2 B 1"

GL SO C 0

BT OP 10 EM HV 8837A M-02EM02 C-7 2 B 1"

GL SO C 0

FST OP EM HV 8837A M-02EM02 C-7 2 B 1"

GL SO C 0

PIT RR EM-4 EM HV 8837B M-02EM02 B-7 2 B 1"

GL S0 C 0

BT OP 10 EM HV 8837B M-02EM02 B-7 2 B 1"

GL SO C 0

FST OP EM HV 8837B M-02EM02 B-7 2 B 1"

GL SO C 0

PIT RR EM-4 EM HV 8843 M-02EM02 C-4 2 B

.75" GL A0 C C

BT OP 10

-EM HV 8843 M-02EM02 C-4 2 B

.75" GL A0 C C

FST OP EM HV 8843 M-02EM02 C-4 2 B

.75" GL A0 C C

PIT RR EM HV 8870A M-02EM02 E-5 2 B 1"

GL A0 0 C

FST OP EM HV 8870A M-02EM02 E-5 2 B

_ 1" GL A0 0 C

PIT RR EM HV 8870A M-02EM02 E-5 2 B 1"

GL A0 0 C

BT OP 5 EM HV 8870B M-02EM02 E-5 2 B 1"

GL A0 0

.C BT OP 5 EM HV 8870B M-02EM02 E-5 2 B 1"

GL A0 0 C

FST OP EM HV 8870B M-02EM02 E-5 2 B 1"

GL A0 0 C

PIT RR EM HV 8882 M-02EM02 C-3 2 B

.75" GL A0 C C

NA 3

EM HV 8883 M-02EM02 D-6 2 B 1"

GL A0 0 C

BT OP 5 EM HV 8883 M-02EM02 D-6 2 B 1"

GL A0 0 C

FST OP EM HV 8883 M-02EM02 D-6 2 B 1"

GL A0 0

,C PIT RR EM V C014 M-02EM02 E-6 2 C 1"

CK SA C C

NA 12 EM V 0017 M-02EM02 D-6 2 C 1"

CK SA C C

NA 12 EM V 02L0 M-02EM02 C-7 2 C 1"

CK SA C 0

CVT RR EM-3 5 EM V 0241 M-02EM02 B-7 2 C 1"

CK SA C 0

CVT RR EM-3 5

Pegs 31 INSERVICE TESTING PROGRAM SY VLV-NUMBER

  • -P+ID
  • SIZE TYP AT POS DIR TST TM MAX *R/R
  • NOTES
  • EN HV 0001 M-02EN01 G-7 2 B 12" GA M0 C C/0 BT RR 30 EN-4 6,5 EN HV 0001, M-02EN01 G-7 2 B 12" GA MO C C/0 PIT RR EN HV 0006 M-02EN01 G-4 2 B 10" GA MO C 0

BT OP 15 6

EN HV 0006 M-02EN01 G-4 2 B 10" GA M0 C 0

PIT RR EN HV.0007 M-02EN01 B-7 2 B 12" GA MO C C/0 BT RR 30 EN-4 6,5 EN HV 0007 M-02EN01 B-7 2 B 12" GA MO C C/0 PIT RR EN HV 0012 M-02EN01 B-4 2 B 10" GA MO C 0

BT OP 15 6

EN HV 0012 M-02EN01 B-4 2 B 10" GA MO C 0

PIT RR l

EN HV 0015 M-02EN01 E-6 2 B 3"

GA MO C 0

BT OP 8 EN HV 0015 M-02EN01 E-6 2 B 3"

GA MO C 0

PIT RR l

EN HV 0016 M-02EN01 D-6 2 B 3"

GA M0 C 0

BT OP 8 EN HV 0016 M-02EN01 D-6 2 B 3"

GA MO C 0

PIT RR EN V 0002 M-02EN01 G-7 2 C 12" CK SA C 0

CVT RR EN-1 5 EN V 0003 M-02EN01 G-7 2 C 12" CK SA C 0

CVP OP EN-2 EN V 0004 M-02EN01 G-5 2 C 10" CK SA C 0

CVP OP EN-2 EN V 0008 M-02EN01 B-7 2 C 12" CK SA C 0

CVT RR EN-1 5 EN V 0009 M-02EN01 B-7 2 C 12" CK SA C 0

CVP OF EN-2 EN V 0010 M-02EN01 B-5 2 C 10" CK SA C 0

CVP OP EN-2 EN V 0013 M-02EN01 G-4 2 C 10" CK SA C 0

CVT RR EN-3 5 EN V 0017 M-02EN01 B-4 2 C 10" CK SA C 0

CVT RR EN-3 5 EN V 0057 M-02EN01 F-5 2 C

.75" RV SA C C

RVT 2

EN V 0058 M-02EN01 F-5 2 C 1"

RV SA C 0

RVT 2

EN V 0099 M-02EN01 F-6 2 C 3"

CK SA C 0

CVT OP EN V 0101 M-02EN01 C-6 2 C 3"

CK SA C 0

CVT OP EN V 0106 M-02EN01 F-5 2 C 1"

RV SA C 0

RVT 2

l l

r i

y

.,__.~.,

,.._y

Paga 32 s

INSERVICE TESTING PROGRAM SY VLV-NUMBER

  • -P+ID
  • SIZE TYP AT POS DIR TST TM MAX *R/R
  • NOTES
  • l-EP 8818A M-02EP01 G-3 1 A,C 6"

CK SA C O/C AT CS V05 7 EP 8818A M-02EP01 G-3 1 A,C 6"

CK SA C O/C CVT CS EP-1 5 l

EP 8818B M-02EP01 F-3 1 A,C 6"

CK SA C O/C AT CS V05 7 EP 8818B M-02EP01 F-3 1 A,C 6"

CK SA C O/C CVT CS E?-1 5 l

EP 8818C M-02EP01 D-3 1 A.C. 6" CK SA C O/C AT CS V05 7 EP 8818C M-02EP01 D-3 1 A,C 6"

CK SA C O/C CVT CS EP-1 5 i

EP 8818D M-02EP01 C-3 1 A,C 6"

CK SA C O/C AT CS V05 7 EP 8818D M-02EP01 C-3 1 A,C 6"

CK SA C O/C CVT CS EP-1 5 EP 8855A M-02EP01 H-7 2 C 1"

RV SA C 0

RVT 2

EP 8855B M-02EP01 F-7 2 C 1"

RV SA C 0

RVT 2

.EP 8855C M-02EP01 D-7 2 C 1"

RV SA C 0

RVT 2

EP 8855D M-02EP01 C'-7 2 C 1"

RV SA C 0

RVT 2

i EP 8956A M-02EP01 G-4 1 A,C 10" CK SA C 0

AT CS V05 7 EP 8956A M-02EP01 G-4 1 A,C 10" CK SA C 0

CVP RR EP-2 5 i

EP 8956B M-02EP01 E-4 1 A,C 10" CK SA C 0

AT CS VOS 7 EP 8956B M-02EP01 E-4 1 A,C 10" CK SA C 0

CVP RR EP-2 5 l

EP 8956C M-02EP01 C-4 1 A,C 10" CK SA C 0

AT CS V05 7 EP 8956C M-02EP01 C-4 1 A,C 10" CK SA C 0

CVP RR EP-2 5 l

EP 8956D M-02EP01 B-4 1 A,C 10" CK SA C 0

AT CS V05 7 EP 8956D M-02EP01 B-4 1 A,C 10" CK SA C 0

CVP RR EP-2 5 EP HV 8808A M-02EP01 G-5 2 B 10" GA MO O O

NA 1,3 EP HV 8808B M-02EP01 E-5 2 B 10" GA MO O O

NA~

1,3 EP HV 8808C M-02EP01 C-5 2 B 10" GA MO O O

NA 1,3 EP HV 8808D M-02EP01 B-5 2 B 10" GA MO O O

NA 1,3 EP HV 8875A M-02EP01 H-6 2 B 1"

GL A0 C C

NA 3

EP HV 8875B M-02EP01 F-6 2 B 1"

GL A0 C C

NA 3

EP HV 8875C M-02EP01 D-6 2 B 1"

GL A0 C C

NA 3

EP HV 8875D M-02EP01 C-6 2 B 1"

GL A0 C C

NA 3

EP HV 8877A M-02EP01 F-4 2 B

.75" GL A0 C C

NA 3

EP HV.8877B M-02EP01 E-4 2 B

.75" GL A0 C C

NA 3

EP HV 8877C M-02EP01 C-4 2 B

.75" GL A0 C C

NA 3

EP HV 8877D M-02EP01 A-4 2 B

.75" GL A0 C C

NA 3

EP HV 8878A M-02EP01 G-5 2 B 1"

GL A0 C C

NA 3

EP HV.8878B M-02EP01 E-5 2 B 1"

GL A0 C C

NA 3

EP HV 8878C M-02EP01 D-5 2 B 1"

GL A0 C C

NA 3

EP HV 8878D M-02EP01 B-5 2 B 1"

GL A0 C NA 3

C EP HV 8879A M-02EP01 G-4 2 B

.75" GL A0 C C

NA 3

EP HV 8879B M-02EP01 E-4 2 B

.75" GL A0 C C

NA 3

EP HV 8879C M-02EP01 D-4 2 B

.75" GL A0 C C

NA 3

EP HV 8879D M-02EP01 C-2 2 B

.75" GL A0 C C

NA 3

l EP HV 8880 M-02EP01 A-4 2 A 1"

GL A0 C C

AT RR V04 9,10 EP HV 8950A M-02EP01 H-7 2 B 1"

GL S0 C 0

BT RR 10 EP-4 5 EP RV 8950A M-02EP01 H-7 2 B 1"

GL SO C 0

PIT RR EP HV 8950B M-02EP01 F-8 2 B 1"

GL SO C 0

BT RR 10 EP-4 5 EP HV 8950B M-02EP01 F-8 2 B 1"

GL S0 C 0

PIT RR EP HV 8950C M-02EP01 F-7 2 B 1"

GL S0 C 0

BT RR 10 EP-4 5 EP HV 8950C M-02EP01 F-7 2 B 1"

GL S0 C 0

PIT RR EP HV 8950D M-02EP01 0-8 2 B 1"

GL SO C 0

BT RR 10 EP-4 5 EP HV 8950D M-02EP01 D-8 2 B 1"

GL SO C 0

PIT RR EP HV 8950E M-02EP01 D-7 2 B 1"

GL S0 C 0

BT RR 10 EP-4 5

.EP HV 8950E M-02EP01 D-7 2 B

-1" GL SO C 0

PIT RR EP HV 8950F M-02EP01 C-8 2 B 1"

GL SO C 0

BT RR 10 EP-4 5

Peg:n 33 INSERVICE TESTING PROGRAM SY VLV-NUMBER

  • -P+ID
  • SIZE TYP AT POS DIR TST TM MAX *R/R
  • NOTES
  • EP HV 8950F M-02EP01 C-8 2 B 1"

GL SO C 0

PIT RR l

EP V 0010 M-02EP01 G-3 1 A,C 2"

CK SA C O/C AT CS V05 7 EP V 0010 M-02EP01 G-3 1 A,C 2"

CK SA C O/C CVT RR EP-3 5 i

EP V 0020

'M-02EP01 F-3 1 A,C 2"

CK SA C 0/C AT CS V05 7 EP V 0020 M-02EP01 F-3 1 A,C 2"

CK SA C O/C CVT RR EP-3 5 l

EP V 0030 M-02EP01 D-3 1 A,C 2"

CK SA C O/C AT CS V05 7 EP V 0030 M-02EP01 D-3 1 A,C 2"

CK SA C O/C CVT RR EP-3 5 i

EP V 0040 M-02EP01 C-3 1 A,C 2"

CK SA C O/C AT CS VOS 7 EP V 0040 M-02EP01 C-3 1 A,C 2"

CK SA C O/C CVT RR EP-3 5 l

EP V 0046 M-02EP01 A-5 2 A,C 1"

CK SA C C

AT RR V04 9,10 O

Pega 35 l

INSERVICE TESTING PROGRAM SY VLV-NUMBER

  • -P+ID
  • SIZE TYP AT POS DIR TST TM MAX *R/R
  • NOTES
  • l GS HV 0003 M-02GS01 E-6 2 A 1"

GA SO C O/C AT ~ OP 5 RR V04 10 GS HV 0003 M-02GS01 E-6 2 A 1"

GA SO C O/C BT GS HV 0003 M-02GS01 E-6 2 A 1"

GA SO C O/C FST OP GS HV 0003 M-02GS01 E-6 2 A 1"

GA SO C O/C PIT RR VO-3 l

GS HV 0004 M-02GS01 E-6 2 A 1"

GA SO C O/C AT RR V04 10 GS HV 0004 M-02GS01 E-6 2 A 1"

GA SO C O/C BT OP 5 GS HV 0004 M-02GS01 E-6 2 A 1"

GA SO C O/C FST OP GS HV 0004 M-02GS01 E-6 2 A 1"

GA SO C O/C PIT RR VO-3 l

GS HV 0005 M-02GS01 D-5 2 A 1"

GA SO C O/C AT RR V04 10 GS HV 0005 M-02GS01 D-5 2 A 1"

GA SO C O/C'BT OP 5 GS HV 0005 M-02GS01 D-5 2 A 1"

GA SO C O/C FST OP GS HV 0005 M-02GS01 D-5 2 A 1"

GA SO C O/C PIT RR VO-3 l

GS HV 0008 M-02GS01 B-6 2 A 1"

GA SO C O/C AT RR V04 10 GS HV 0008 M-02GS01 B-6 2 A 1"

GA SO C O/C BT OP 5 GS HV 0008 M-02GS01 B-6 2 A 1"

GA SO C O/C FST OP GS HV 0008 M-02GS01 B-6 2 A 1"

GA SO C O/C PIT RR VO-3 l

GS HV 0009 M-02GS01 B-6 2 A 1"

GA SO C O/C AT RR V04 10 GS HV 0009 M-02GS01 B-6 2 A 1"

GA SO C O/C BT OP 5 GS HV 0009 M-02GS01 B-6 2 A 1"

GA SO C O/C FST OP GS HV 0009 M-02GS01 B-6 2 A 1"

GA SO C O/C PIT RR VO-3 i

GS HV 0012 M-02GS01 E-4 2 A 1"

GA SO C O/C AT RR V04 10 GS HV 0012 M-02GS01 E-4 2 A 1"

GA S0. C O/C BT OP 5 GS HV 0012 M-02GS01 E-4 2 A 1"

GA SO C O/C FST OF GS HV 0012 M-02GS01 E-4 2 A 1"

GA SO C O/C PIT RR VO-3 I

GS HV 0013 M-02GS01 E-5 2 A 1"

GA SO C O/C AT RR V04 10 GS HV 0013 M-02GS01 E-5 2 A 1"

GA SO C O/C BT OP 5 GS HV 0013 M-02GS01 E-5 2 A 1"

GA SO C O/C FST OP GS HV 0013 M-02GS01 E-5 2 A 1"

GA SO C O/C PIT RR VO-3 l

GS HV 0014 M-02GS01 D-5 2 A 1"

GA SO C O/C AT RR V04 10 GS HV 0014 M-02GS01 D-5 2 A 1"

GA SO C O/C BT OP 5 GS HV 0014 M-02GS01 D-5 2 A 1"

GA SO C O/C FST OP GS HV 0014 M-02GS01 D-5 2 A 1"

GA SO C O/C PIT RR VO-3 i

GS HV 0017 M-02GS01 B-4 2 A 1"

GA SO C O/C AT RR V04 10 GS HV 0017 M-02GS01 B-4 2 A 1"

GA SO C O/C BT OP 5 GS HV 0017 M-02GS01 B-4 2 A 1"

GA SO C O/C FST OP GS HV 0017 M-02GS01 B-4 2 A 1"

GA SO C O/C PIT RR-VO-3 l

GS HV 0018 M-02GS01 B-5 2 A 1"

GA SO C O/C AT RR V04 10 GS HV 0018 M-02GS01 B-5 2 A 1"

GA SO C O/C BT OP 5 GS HV 0018 M-02GS01 B-5 2 A 1"

GA SO C O/C FST OP GS HV 0018 M-02GS01 B-5 2 A 1"

GA SO C O/C PIT RR VO-3 l

GS HV 0020 M-02GS01 F-5 2 A 6"

BT M0 C O/C AT RR V04 10 GS HV 0020 M-02GS01 F-5 2 A 6"

BT MO C O/C BT OP 5 6

GS HV 0020 M-02GS01 F-5 2 A 6"

BT M0 C O/C PIT RR l

GS HV 0021 M-02GS01 F-4 2 A 6"

BT MO C O/C AT RR V04 10 GS HV 0021 M-02GS01 F-4 2 A 6"

BT M0 C O/C BT OP 5 6

GS HV 0021 M-02GS01 F-4 2 A 6"

BT M0 C O/C PIT RR l

GS HV 0031 M-02GS01 D-4 2 A 1"

GA SO O C

AT RR V04 10 GS HV 0031 M-02GS01 D-4 2 A 1"

GA SO O C

BT OP 5 GS HV 0031 M-02GS01 D-4 2 A 1"

GA SO O C

FST OP GS HV 0031 M-02GS01 D-4 2 A 1"

GA SO O C

PIT RR VO-3 l

GS HV 0032 M-02GS01 D-3 2 A 1"

GA SO O C

AT RR V04 10 GS HV 0032 M-02GS01 D-3 2 A 1"

GA SO O C

BT OP 5

Paga 36 INSERVICE TESTING PROGRAM SY VLV-NUMBE2

  • -P+ID
  • SIZE TYP AT POS DIR TST TM MAX *R/R
  • NOTES
  • GS HV 0032 M-02GS01 D-3 2 A 1"

GA SO O C

FST OP GS HV 0032 M-02GS01 D-3 2 A 1"

GA SO O C

PIT RR VO-3 l

GS HV 0033 M-02GS01 C-4 2 A 1"

GA SO O C

AT RR V04 10 GS HV 0033 M-02GS01 C-4 2 A 1"

GA SO O C

BT OP 5 GS HV 0033 M-02GS01 C-4 2 A 1"

GA SO O C

FST OP GS HV 0033 M-02GS01 C-4 2 A 1"

GA SO O C

PIT RR VO-3 l

GS HV 0034 M-02GS01 C-4 2 A 1"

GA SO O C

AT RR V04 10 GS HV 0034 M-02GS01 C-4 2 A 1"

GA SO O C

BT OP 5 GS HV 0034 M-02GS01 C-4 2 A 1"

GA SO O C

FST OP GS HV 0034 M-02GS01 C-4 2 A 1"

GA SO O C

PIT RR V0-3 l

GS HV 0036 M-02GS01 D-6 2 A 1"

GA SO O C

AT RR V04 10 GS UV 0036 M-02GS01 D-6 2 A 1"

GA SO O C

BT OP 5 GS HV 0036 M-02GS01 D-6 2 A 1"

GA SO O C

FST OP GS HV 0036 M-02GS01 D-6 2 A 1"

GA SO O

.C PIT RR VO-3 i

GS HV 0037 M-02GS01 D-7 2 A 1"

GA SO O C

AT RR V04 10 GS HV 0037 M-02GS01 D-7 2 A 1"

GA SO O C

BT OP 5 GS HV 0037 M-02GS01 D-7 2 A 1"

GA SO O C

FST OP GS HV 0037 M-02GS01 D-7 2 A 1"

GA SO O C

PIT RR VO-3 l

GS HV 0038 M-02GS01 C-6 2 A 1"

GA SO O C

AT RR V04 10 GS HV 0038 M-02GS01 C-6 2 A 1"

GA SO O C

BT OP 5 GS HV 0038 M-02GS01 C-6 2 A 1"

GA SO O C

FST OP GS HV 0038 M-02GS01 C-6 2 A 1"

GA SO O C

PIT RR VO-3 l

GS HV'0039 M-02GS01 C-6 2 A 1"

GA SO O C

AT RR V04 10-GS HV 0039 M-02GS01 C-6 2 A 1"

GA SO O C

BT OP 5 GS HV 0039 M-02GS01 C-6 2 A 1"

GA SO O C

FST OP GS HV 0039 M-02GS01 C-6 2 A 1"

GA SO O C

PIT RR V0-3

Paga 37 INSERVICE TESTING PROGRAM SY VLV-NUMBER

  • -P+ID
  • SIZE TYP AT POS DIR TST TM MAX *R/R
  • NOTES
  • l GT HZ 0004 M-02GT01 D-4 2 A 18" BT A0 0 C

AT RR V04 10 GT HZ 0004 M-02GT01 D-4 2 A 18" BT A0 0 -

C BT OP 3 GT HZ 0004 M-02GT01 D-4 2 A 18" BT A0 0 C

FST OP GT HZ 0004 M-02GT01 D-4 2 A 18" BT A0 0 C

PIT RR l

GT HZ 0005 M-02GT01 A-5 2 A 18" BT A0 0 C

AT RR V04 10 GT HZ 0005 M-02GT01 A-5 2 A 18" BT A0 0 C

BT OP 3 GT HZ 0005 M-02GT01 A-5 2 A 18" BT A0 0 C

FST OP GT HZ 0005 M-02GT01 A-5 2 A 18" BT A0 0 C

PIT RR l

GT HZ 0006 M-02GT01 C-4 2 A 36" BT A0 C C

AT RR V04 9,10 l

GT HZ 0007 M-02GT01 C-5 2 A 36" BT A0 C C

AT RR V04 9,10 1

GT HZ 0008 M-02GT01 C-6 2 A 36" BT A0 C C

AT RR V04 9,10 l

GT HZ 0009 M-02GT01 C-7 2 A 36" BT A0 C C

AT RR V04 9,10 i

GT HZ 0011 M-02GT01 A-6 2 A 18" BT A0 0 C

AT RR V04 10 GT HZ 0011 M-02GT01 A-6 2 A 18" BT A0 0 C

BT OP 3 GT HZ 0011 M-02GT01 A-6 2 A 18" BT A0 0 C

FST OP GT HZ 0011 M-02GT01 A-6 2 A 18" BT A0 0 C

PIT RR l

GT HZ 0012 M-02GT01 A-7 2 A 18" BT A0 0 C

AT RR V04 10 GT HZ 0012 M-02GT01 A-7 2 A 18" BT A0 0 C

BT OP 3 GT HZ 0012 M-02GT01 A-7 2 A 18" BT A0 0 C

FST OP GT HZ 0012 M-02GT01 A-7 2 A 18" BT A0 0 C

PIT RR 9

Paga 38 INSERVICE TESTING PROGRAM SY VLV-NUMBER

  • -P+ID
  • SIZE TYP AT POS DIR TST TM MAX *R/R
  • NOTES
  • l HB HV 7126 M-02HB01 G-6 2 A

.75" DI A0 0 C

AT RR V04 10 HB HV 7126 M-02HB01 G-6 2 A

.75" DI A0 0 C

BT OP 10 HB HV 7126 M-02HB01 G-6 2 A

.75" DI A0 0 C

FST OP HB HV 7126 M-02HB01 G-6 2 A

.75" DI A0 0 C

PIT RR l

HB HV 7136 M-02HB01 F-3 2 A 3"

DI A0 0 C

AT RR V04 10 HB HV 7136 M-02HB01 F-3 2 A 3"

DI A0 0 C

BT OP 10 HB HV 7136 M-02HB01 F-3 2 A 3"

DI A0 0 C-FST OP HB HV 7136 M-02HB01 F-3 2 A 3"

DI A0 0 C

PIT RR l

HB HV 7150 M-02HB01 G-5 2 A

.75" DI A0 0 C

AT RR V04 10 HB HV 7150 M-02HB01 G-5 2 A

.75" DI A0 0 C

BT OP 10 HB HV 7150 M-02HB01 G-5 2 A

.75" DI A0 0 C

FST OP HB HV 7150 M-02HB01 G-5 2 A

.75" DI A0 0 C

PIT RR l

HB HV 7176 M-02HB01 F-3 2 A 3"

DI A0 0 C

AT RR V04 10 HB HV 7176 M-02HB01 F-3 2 A 3"

DI A0 0 C

BT OP 10 HB HV 7176 M-02HB01 F-3 2 A 3"

DI A0 0 C

FST OP HB HV 7176 M-02HB01 F-3 2 A 3"

DI A0 0 C

PIT RR HB V 0036 M-02HB01 C-3 3 C

.75" RV SA C 0

RVT RR 2

i

Paga 39 INSERVICE TESTING PROGRAM SY VLV-NUMBER

  • -P+ID
  • SIZE TYP AT POS DIR TST TM MAX *R/R
  • NOTES
  • l HD V 0016 M-02HD01 B-7 2 A

'2" GL M C C

AT. RR V04 1,9,11 l

HD V 0017 M-02HD01 B-7 2 A 2"

GL M C C

AT RR V04 1,9,11 i

I i

4 4

-s 4

e s--

v--,,--.v.-,, - - -, - - - - - - < -,,- -

-,m

--v.,-

-,,,,..------e..,,-~,-.--.-w----

Paga 40 INSERVICE TESTING PROGRAM SY VLV-NUMBER

  • -P+ID
  • SIZE TYP AT POS DIR TST TM MAX *R/R
  • NOTES
  • l KA FV 0029 M-02KA01 D-2 2 A 2"

GL A0 0 C

AT RR V04 10 KA FV 0029 M-02KA01 D-2 2 A 2"

GL A0 0 C

BT CS 5 KA-1 5 KA FV 0029 M-02KA01 D-2 2 A 2"

GL A0 0 C

FST CS KA-1 KA FV 0029 M-02KA01 D-2 2 A 2"

GL A0 0 C

PIT RR KA HV 0030 M-02KA01 C-1 2 B 1.5" GA M0 C 0

BT CS 12 KA-1 5 KA HV 0030 M-02KA01 C-1 2 B 1.5" GA M0 C 0

PIT RR KA V 0204 M-02KA01 C-2 2 A,C 1.5" CK SA 0 C

AT RR V04 5,11 l

KA V 0204 M-02KA01 C-2 2 A,C 1.5" CK SA 0 C

CVT RR KA-2 4

b

p i

~'

Pcg3 41 INSERVICE TESTING PROGRAM SY VLV-NUMBER

  • -P+ID
  • SIZE TYP AT POS DIR TST TM MAX *R/R
  • NOTES
  • l KA V 0039 M-02KA02 D-6 2 A,C 4"

C1 FA C C

AT T5 V04 9,11 l

KA V 0118 M-02KA02 D-6 2 A

- 4" GL M C C

AT KR V04 1,9,11 4

j.

/

e w e

'l

-4

/

s W

k 4

f

.a o

4

(

t i

i i

t-i e

t

?

J i

m

Pag 3 43 INSERVICE TESTING PROGRAM SY VLV-NUMBER

  • -P+ID
  • SIZE TYP AT POS DIR TST TM MAX *R/R
  • NOTES
  • l KC HV 0253 M-02KC02 B-6 2 A 4"

GA MO C C

AT RR V04 9,11 i

KC V 0478 M-02KCO2 B-6 2 A,C 4" ~

CK SA C C

AT RR V04 9,11

Peg 2 48 INSERVICE TESTING PROGRAM SY VLV-NUMBER

  • -P+ID
  • CRD I CAT ~* SIZE TYP AT POS DIR TST TM MAX *R/R
  • NOTES
  • l LF FV 0095 M-02LF09 F-2 2 A 6"

GA MO O C

AT RR V04 10 LF FV 0095 M-02LF09 F-2 2 A 6"

GA MO O C

BT OP 30 6

LF FV 0095 M-02LF09 F-2 2 A 6"

GA MO O C

PIT RR l

LF FV 0096 M-02LF09 F-2 2 A 6"

GL A0 C C

AT RR V04 10 LF FV 0096 M-02LF09 F-2 2 A 6"

GL A0 C C

BT OP 4 LF FV 0096 M-02LF09 F-2 2 A 6"

GL A0 C C

FST OP LF FV 0096 M-02LF09 F-2 2 A 6"

GL AO C C

PIT RR 4

Pags 49 INSERVICE TESTING PROGRAM SY VLV-NUMBER

  • -P+ID
  • SIZE TYP AT POS DIR TST TM MAX *R/R
  • NOTES
  • 1 SJ HV 0012 M-02SJ01 F-7 2 A 1"

GL S0 C C

AT RR V04 10 SJ HV 0012 M-02SJ01 F-7 2 A 1"

GL SO C C

BT OP 5 SJ HV 0012 M-02SJ01 F-7 2 A 1"

GL S0 C C

FST OP SJ HV 0012 M-02SJ01 F-7 2 A 1"

GL SO C C

PIT RR VO-3 l

SJ HV 0013 M-02SJ01 E-7 2 A 1"

GL' SO C C

AT RR V04 10 SJ HV 0013 M-02SJ01 E-7 2 A 1"

GL S0 C C

BT OP 5 SJ HV 0013

'M-02SJ01 E-7 2 A 1"

GL SO C C

FST OP SJ HV 0013 M-02SJ01 E-7 2 A 1"

GL SO C C

PIT RR VO-3 l

SJ HV 0018 M-02SJ01 F-3 2 A 1"

GL SO C C

AT RR V04 10 SJ HV 0018 M-02SJ01 F-3 2 A 1"

GL SO C C

BT OP 5 SJ HV 0018 M-02SJ01 F-3 2 A 1"

GL SO C C

FST OP SJ HV 0018 M-02SJ01 F-3 2 A 1"

GL S0 C C

PIT RR V0-3 l

SJ HV 0019 M-02SJ01 E-3 2 A 1"

GL SO C C-AT RR V04 10 SJ HV 0019 M-02SJ01 E-3 2 A 1"

GL S0 C C

BT OP 5 SJ HV 0019 M-02SJ01 E-3 2 A 1"

GL S0 C C

FST OP SJ HV 0019 M-02SJ01 E-3 2 A 1"

GL SO C C

PIT RR VO-3 e

d

Pagt 50 INSERVICE TESTING PROGRAM SY VLV-NUMBER

  • -P+ID
  • SIZE TYP AT POS DIR TST TM MAX *R/R
  • NOTES
  • SJ HV 0003 M-02SJ04 F-7 2 B 1"

GL SO C C

NA 3

SJ HV 0004 M-02SJ04 H-7 2 B 1"

GL S0 C C

NA 3

l SJ HV 0005 M-02SJ04 F-7 2 A 1"

GL SO O C

AT RR V04 10 SJ HV 0005 M-02SJ04 F-7 2 A 1"

GL SO O C

BT OP 5 SJ HV 0005 M-02SJ04 F-7 2 A 1"

GL SO O C

FST OP SJ HV 0005 M-02SJ04 F-7 2 A 1"

GL SO O C

PIT RR VO-3 l

SJ HV 0006 M-02SJ04 F-6 2 A 1"

GL SO O C

AT RR V04 10 SJ HV 0006 M-02SJ04 F-6 2 A 1"

GL SO O C

BT OP 5 SJ HV 0006 M-02SJ04 F-6 2 A 1"

GL SO O C

FST OP SJ HV 0006 M-02SJ04 F-6 2 A 1"

GL SO O - C PIT RR VO-3 SJ HV 0020 M-02SJ04 G-7 2 B 1"

GL SO C C

NA 3

l SJ HV 0127 M-02SJ04 F-6 2 A 1"

, GL SO C C

AT RR V04 10 SJ HV 0127 M-02SJ04 F-6 2 A 1"

GL SO C C

BT OP 5 SJ HV 0127 M-02SJ04 F-6 2 A 1"

GL SO C C

FST OP SJ HV 0127 M-02SJ04 F-6 2 A 1"

GL S0 C C

PIT RR VO-3 l

SJ HV 0128 M-02SJ04 H-6 2 A 1"

GL SO O C

AT RR V04 10 SJ HV 0128 M-02SJ04 H-6 2 A 1"

GL SO O C

BT OP 5 SJ HV 0128 M-02SJ04 H-6 2 A 1"

GL SO O C

FST OP SJ HV 0128 M-02SJ04 H-6 2 A 1"

GL SO O C

PIT RR VO-3 l

SJ HV 0129 M-02SJ04 H-5 2 A 1"

GL SO O C

AT RR V04 10 SJ HV 0129 M-02SJ04 H-5 2 A 1"

GL SO 0~

C BT OP 5 SJ HV 0129 M-02SJ04 H-5 2 A 1"

GL SO O C

FST OP SJ HV 0129

~ M-02SJ04 H-5 2 A 1"

GL SO O C

PIT RR VO-3 l

SJ HV 0130 M-02SJ04 G-E 2 A 1"

GL SO C' C

AT RR V04 10 SJ HV 0130 M-02SJ04 G-5 2 A 1"

GL SO C C

BT OP 5 SJ HV 0130 M-02SJ04 G-5 2 A 1"

GL SO C C

FST OP SJ HV 0130 M-02SJ04 G-5 2 A 1"

GL SO C C

PIT RR VO-3 l

SJ HV 0131 M-02SJ04 B-6 2 A 1"

GL SO C C

AT RR V04 10 SJ HV 0131 M-02SJ04 B-6 2 A 1"

GL SO C C

BT OP 5 SJ HV 0131 M-02SJ04 B-6 2 A 1"

GL SO C C

FST OP SJ HV 0131 M-02SJ04 B-6 2 A 1"

GL SO C C

PIT RR VO-3 i

SJ HV 0132 M-02SJ04 A-6 2 A 1"

GL SO C C

AT RR V04 10 SJ HV 0132 M-02SJ04 A-6 2 A 1"

GL SO C C

BT OP 5 SJ HV 0132 M-02SJ04 A-6 2 A 1"

GL SO C C

FST OP SJ HV 0132 M-02SJ04 A-6 2 A 1"

GL SO C C

PIT RR VO-3 SJ V 0101 M-02SJ04 G-7 2 C 1"

CK SA C C

NA 3

l SJ V 0111 M-02SJ04 A-7 2 A,C 1"

CK SA C C

AT RR V04 9,11

RELIEF REQUEST #P08 SYSTEM:

Safety Related COMPONENT:

All pumps listed in the program.

CLASS:

2&3 FUNCTION:

To provide flow to safety related systems.

TEST REQUIREMENT: The direction of displacement shall be measured in a plane approximately perpendicular to the rotating shaft, and in the horizontal or vertical direction that has the largest deflection for the particular pump installation.

BASIS FOR RELIEF: Some bearing housings have obstructions such as oil fill caps, sight glasses, bolts, rigid supports, etc., which prevent obtaining valid vibration data in the perfectly horizontal or vertical direction.

ALTERNATE TESTING:

The direction of displacement shall be measured in a plane approximately perpendicular to the rotating shaft, and in approximately the horizontal or vertical direction that has the largest deflection for the particular_ pump installation.

DE LE TE RELIEF REQUEST #V01 VALVE: BB 118, V148, V178, v208 BG-V 5, BG-8381 BL-804 BM-V045, V046 EC-V083, 84, V087, V088, V095, V096 EG-V204, E 006, EP-V046 HD-V016, V017 KA-V039, V118, 04 KC-V478, SJ-Vill CATEGORY:

A, C CLASS:

2 FUNCTION: Provides contains t isolatio TEST REQUIRENENT: Exer se check valve (ful stroke) to the position r

ired to fulfill its fun ion every 3 months.

BASIS FOR RELIEF System design does not provide a indication for verifying valve closure upon flow versal.

ALTERNA STING: Verify valve closure during performanc of leak rate test during refueling.

l I

e,

,,,w-

---,r-v -

- ~

L

(

RELIEF REQUEST #V04 VALVE:

All Containment Isolation Valves CATEGORY:

A CLASS:

2 FUNCTION:

Provides containment isolation.

TEST REQUIREMENT:

Perform valve leak rate test per section IWV-3420 BASIS FOR RELIEF:

10 CFR 50, Appendix J Primary Reactor Containment Leakage Testing for Water-Cooled Power Reactors, provides leakage test requirements for containment isolation valves. Technical Specifications provide ACTION statements to be adhered to in the event of test failure.

ALTERNATE TESTING:

Valve leak rate testing for containment isolation valves will be performed to the leak test require-ments of 10 CFR 50, Appendix J, and Technical Specifications. This includes requirements for test frequency, differential test pressure, seat leakge measurement, test medium, analysis of leak-age rates and corrective action.

1 l

i e,

~,

r--

,-.e,-a.


,r,,

~-~ ~

RELIEF REQUEST #V05 VALVE:

BB-8948A, B, C, D BB-8949A, B, C, D BB-V-0001, 0022, 0040, 0059 BB-PV-8702A, B EJ-8841A, B EJ-HV-8701A, B EM-V-0001, 0002, 0003, 0004 EM-8815 EP-V-0010, 0020, 0030, 0040 EP-8818A, B, C, D EP-8956A, B, C. D CATEGORY:

A CLASS:

1 FUNCTION:

Provide Reactor Coolant System Pressure Isolation.

TEST REQUIREMENT:

Perform valve leak rate test per sections IWV-3421 thru IWV-3427.

BASIS FOR RELIEF:

Reactor Coolant System Pressure Isolation Valves are sufficiently leak tested per Callaway Plant Technical Specification 4.4.6.2.2.

ALTERNATE TESTING:

Reactor Coolant System Pressure Isolation Valves will be leak tested in accordance with Technical Specifi-cation 4.4.6.2.2.

RELIEF REQUEST #KA 2 VALVE:

KA-V-204 CATEGORY:

A, C CLASS:

2 FUNCTION:

- Provides containment isolation.

TEST. REQUIREMENT: Exercise check valve (full stroke) to the position required to fulfill its function every 3 months.

BASIS FOR RELIEF:

System design does not provide any indication for verifying valve closure upon flow reversal.

ALTERNATE TESTING:

Verify valve closure during performance of leak rate test required to be performed during re-fuel ing.

1 0

aeI UNION ELECTRIC COMPANY 1901 Grotiot Street St. Louis Donald F. Schnell Vice President June 28, 1985 Mr. Harold R. Denton, Director

. Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, DC 20555 ULNRC-ll27

Dear Mr. Denton:

DOCKET NUMBER 50-483 CALLAWAY PLANT, UNIT 1 CALLAWAY PUMP AND VALVE INSERVICE TESTING PROGRAM

References:

1) ULNRC-738 dated January 31, 1984
2) ULNRC-833 dated May 29, 1984
3) ULNRC-1039 dated February 11, 1985 References 1, 2, and 3 transmitted the Callaway Pump and Valve Inservice Testing Program and an update to the program.

Included as attachments to this letter are further updates to the Callaway testing program. is a brief description of the changes, and Attachment 2 contains revised replacement pages.

If there are any questions, please contact us.

Very truly yours, Donald F. Schnell WEK/WAW/kc Attachments

/

9 Mailing Address PO Box 149, St. Louis, MO 63166

STATE OF MISSOURI )

)

SS CITY OF ST. LOUIS-)

Donald F. Schnell, of lawful age, being first duly sworn upon oath says that he is Vice President-Nuclear and an officer of Union Electric Company; that he has read the foregoing document and knows the content thereof; that he has executed the same for and on behalf of said company with full power and authority to do so; and that the facts therein stated are true and correct to the best of his knowledge, information and belief.

)

J By Donald F. Schnell Vice President Nuclear SUBSCRIBED and sworn to before me this M [ h day of 1985' dwD Pg BARGARA@. FFA NOTARY PUCLIO. STATE OF MISSOUR1 MY COMM:SSION EXP!RES APRIL 22, 1933 ST. LOUIS COUNTY

cc:

Gerald Charnoff, Esq.

Shaw, Pittman, Potts & Trowbridge 1800 M. Street, N.W.

Washington, D.C.

20036 Nicholas A. Petrick Executive Director SNUPPS 5 Choke Cherry Road Rockville, Maryland 20850 G. C. Wright Division of Projects and Resident Programs, Chief, Section lA U.S. Nuclear Regulatory Commission Region III 799 Roosevelt Road Glen Ellyn, Illinois 60137 Bruce Little Callaway Resident Office U.S. Nuclear Regulatory Commission RR51 Steedman, Missouri 65077 Tom Alexion Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Mail Stop P-316 7920 Norfolk Avenue Bethesda, MD 20014

t bec:

3456-0021.6 w//A Nuclear Date DFS/ Chrono D.

F.

Schnell J. F. McLaughlin J. E. Birk W. H. Weber F.

D. Field R. J. Schukai M. A. Stiller S. E. Miltenberger a'l*

H. Wuertenbaecher D. W. Capone A. C. Passwater T. H. McFarland R.

P. Wendling D.

E.

Shafer D. J. Walker G. P.

Rathbun (KG&E)_

J. H. Smith (Bechtel)

G56.37 (CA-460)

Compliance (J. E. Davis)

NSRB (Laura Robertson)

W. A. Witt (CA-460) u/la