ML20138Q925

From kanterella
Jump to navigation Jump to search

Forwards Technical Analyses of Electray Hanger Rods in Unit 1 Mechanical Pipe Chase & Unit 2 Auxiliary Feedwater Pump Room,In Response to NRC Re Violations Noted in Insp Repts 50-369/84-28 & 50-370/84-25
ML20138Q925
Person / Time
Site: McGuire, Mcguire  Duke Energy icon.png
Issue date: 11/04/1985
From: Tucker H
DUKE POWER CO.
To: Grace J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML20138Q927 List:
References
TAC-60320, TAC-60321, NUDOCS 8511180337
Download: ML20138Q925 (1)


Text

-

y

.,?

,2.*-

DUKE POWER GOMPANY NUGLEAR PRODUGTION DEPARTMENT P.O. nox 33180,422 MOUT I CIEUltCII STfEET

.0.2883 5

CIIA H (704) 373-4011 November 4, 1985

' Dr. J. Nelson Grace, Regional Administrator U. S. Nuclear Regulatory Commission Region II 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323

Subject:

McGuire Nuclear Station Docket Nos. 50-269 and 50-370

Reference:

RII:MDH NRC/01E Inspection Report 50-369/84-28 and 50-370/84-25

Dear Dr. Grace:

Please find attached two technical analyses to further support Duke Power Company's denial of Violation IV of the subject report. This information is in response to the NRC's letter of August 8, 1985, to Duke Power Company and as committed to in a letter of August 20, 1985, by H. B. Tucker.

Based on an October 25, 1985 telephone conversation between Mr. P. Madden, NRC/ Region II and Mr. H. D. Brandes, Duke Power, an extension until November 4, 1985, was granted for submittal of this information.

If there are any further questions regarding this matter, please advise.

H. B. Tucker, Vice President Nuclear Production Department WHM/hrp Attachments cc:

Mr. W. T. Orders NRC Resident Inspector McGuire Nuclear Station 8511180337 851104 i

PDR ADOCK 05000369

}1 G

PM g

l Z$0]

3