ML20138J382

From kanterella
Jump to navigation Jump to search
Rev 2 to Standing Order 38, Reactor Low Level Alarm Response W/Yarways Out of Svc
ML20138J382
Person / Time
Site: Oyster Creek
Issue date: 10/22/1985
From:
GENERAL PUBLIC UTILITIES CORP.
To:
Shared Package
ML20138J356 List:
References
PROC-851022, NUDOCS 8510290327
Download: ML20138J382 (10)


Text

s Number OYSTER CREEK NUCLEAR GENERATING (UCIGar STATION PROCEDURE Standing Order 38 Revision No.

Reactor Low Level Alarm Response with Yarways Out-of-Service 2

Applicabdity/ Scope Responsible Office Plant ations Applies to work at Oyster Creek This document is important to safety B Yes O No Effective Date ThisRevision2incorpoYligEyggygg{p]gn Temporary Changes:

TC-10/21/85-2 Page Revision 1.0 2

2.0 0

3.0 2

4.0 I

5.0 0

6.0 0

7.0 1

8.0 1

El-1 1

E2-1 1

NON-CONTPOLLU.

Thg r,r;.cacnont Yv,. NOt a ;(opt Up To Date h,D $Ntot Ct00k Signature Concurring Organization Element Date Originator h h [ [ h 9 eve /-ss Operations Control

/o. 22 W Concurred by bh[L.

Plant Operations Director

/8[Il[g[

INM h

PRG Chairman

/0

  • 2Z 8[

(/ (;

~

v 5;:

=

B510290'3r 85 jg9 PDR ADOCK 0 PDR j

P Q

Approved by Vice President and Director, O.C. /

&[NI A00oloS1

~

84 2

(12048) 10

Number OYSTER CREEK NUCLEAR GENERATING NUCIGar STATION PROCEDURE Standing Order 38 Revision No.

Reactor Low Level Alarm Response with Yarways Out-of-Service o

1.0 APPLICAE,ILITY 1.1 This Standing Order provides direction for response to Reactor Vessel Low Level Alarms (H-7-e, H-8-e) and/or unexpected changes in reactor vessel water level greater than 10" during reactor shutdown with the Yarway reactor vessel water level instrumentation disabled.

1.2 This Standing Order provides for Standby Gas Treatment System Initiation, if normal Reactor Building ventilation becomes inoperable while the Yarway reactor water level instrumentation is disabled.

1.3 This Standing Order provides direction for assuring that the Core Spray System remains filled, if power to MCC IB21A, MCC 1821B or to the core spray fill pumps is lost.

CAUTION:

HHEN THE YARWAY LEVEL INSTRUMENTS ARE DISABLED, AUTOMATIC INITIATION OF THE SAFETY SYSTEMS AT THE 'LOH-LOW' LEVEL IS NOT OPERABLE.

BY THIS STANDING ORDER MANUAL INITIATION OF THE 'LOH-LOW' LEVEL SAFETY FUNCTIONS IS REQUIRED AT THE

' LOW' LEVEL AS AN ADDITIONAL MARGIN OF SAFETY.

S 5

o 3

2 i

a i

A i s ii.82 2.0

4MC.Sar OYSTER CREEK NUCLEAR GENERATING I

STATION PROCEDURE Standing Order 38 ReWsion No.

Reactor Low Level Alarm Response with Yarways Out-of-Service 2

2.0 PREREQUISITES 2.1 Reactor is in cold shutdown condition and primary containment integrity is no longer required, AND The requirements of note gg to Technical Specification Table 3.1.1 are met.

gg) "These functions.are not required to be operable when secondary containment is not required to be maintained or when the conditions of Section 3.5.B.I.a. b, c, and d are met, and reactor water level is closely monitored and logged hourly. The Standby Gas Treatment System will be manually initiated if reactor water level drops to the low level tr{p setpoint".

2.2 Both core spray systems must, as a minimum, meet the requirements for reduced availability as specified in Technical Specification 3.4.A.7, 3.4.A.8, or 3.4.A.10.

2.3 Annunciator H-8-e, "B GEMAC LO LVL", has been temporarily connected to the "B" GEMAC level instrument. The alarm setpoint 1 146" TAF.

1 5

2.4 Reactor level select switch is positioned to "A" GEMAC level instrument. Annunciator H-7-e, "RX LVL HI/LO", will alarm when 5

"A" GEMAC 1 146" TAF or 1 175" TAF.

2.5 "A"

GEMAC, "B" GEMAC and the wide range GEMAC level instrument h

readings are logged every 30 2 10 minutes.

i!

m m n 82 3.0

<,2o..>

Number Nuclear YSTER CREEK NUCLEAR GENERATING STATION PROCEDURE Standing Order 38 Revision No.

Reactor Low Level Alarm Response with Yarways Out-of-Service 1

2.6 All licensed Control Room personnel shall have read this Standing Order prior to assuming shift responsibilities under the plant conditions to which the Standing Order applies.

2.7 At least one SGTS Train must be available at all times.

2.8 The Emergency Diesel (s) providing power to the Core Spray Pumps and the SGTS Train used to meet the requirements of this Standing Order must be operable and available.

2.9 Any Primary Containment Isolation Valve defined in Table 38-1 that y

is irioperable must be listed in Table 38-2 with a backup isolation valve listed.

s 2

5 1

8 A

i s n 82 4.0

<izo.,>

Number

-gIII lIIIII OYSTER CREEK NUCLEAR GENERATING STATION PROCEDURE Standing Order 38 d'

Reactor Low Level Alarm Response Revision No.

with Yarways Out-of-Service o

3.0 INSTRUCTIONS FOR REACTOR RATER LOH LEVEL Upon receiving a reactor low level alarm, or if an unexpected change in vessel level of 10" or greater is observed on cny narrow or wide range GEMAC level instrument, then take the following actions.

3.1 Confirmatory Action Check the narrow and wide range GEMAC level instruments for rea.ctor water level below 146" TAF.

CAUTION:

AUTOMATIC INITIATION OF SAFETY FUNCTIONS AT THE 'LOH-LOH' LEVEL IS DISABLED HITH YARHAY LEVEL INSTRUMENTS INOPERABLE.

THE FOLLOHING ACTIONS MUST BE PERFORHED MANUALLY.

3.2 Manual Corrective Actions 3.2.1 For Reactor Hater Level Less Than 146" TAF on Any One Level Instrument (Low Hater Alarm Setpoint) or For Unexpected Changes in Vessel Level of 10" or Greater 3.2.1.1 Notify Rad Con to evacuate the drywell.

3. 2.1. 2 Check drywell equipment drain tank and sump for indications of leakage.

If leakage is indicated and if conditions permit, dispatch an operator 5

to the drywell to visually identify leakage.

?

3.2.1.3 Restore reactor water level to the normal range.

5*

3.2.1.4 Continuously monitor water level until it stabilizes in normal range.

a

^**" 5 ".82 tiaa.,>

5.0

Number OYSTER CREEK NUCLEAR GENERATING (UCIGar STATION PROCEDURE Standing Order 38 Revision No.

Reactor Low Level Alarm Response with Yarways Out-of-Service o

3.2.2 For Reactor Water Level Less Than 138" TAF on Any One Level Instrument (Low Hater Scram Setpoint)

_ NOTE:

Reactor level less than 138" TAF constitutes an entry condition for EMG-3200.01, "RPV Control". The below steps should be followed concurrently with EMG-3200.01.

However, EMG-3200.01 takes precedence, if conflicts arise.

CAUTION:

j AUTOMATIC INITIATION OF THE AB0VE SAFETY FUNCTI0flS IS DISABLED HITH YARWAY LEVEL INSTRUMENTATION INOPEP.ABLE.

THE ABOVE ACTIONS MUST BE PERFORMED MANUALLY.

3.2.2.1 Isolate the reactor vessel (MSIV's Isolation Condenser Vent Valves, MSIV drain line valves, V-24-30, Instrument and Nitrogen Supply to Drywell).

3.2.2.2 Start core spray pumps and begin injection into the RPV until it can be determined that RPV level is > 146" TAF.

3.2.2.3 Start diesel generators.

S 3.2.2.4 Initiate Standby Gas Treatment System and 5g confirm Rx Building isolation.

?

O 3.2.2.5 Trip the recirc pump breakers.

T 3.2.2.6 Isolate the Reactor Cleanup System.

O i

3.2.2.7 Isolate the Shutdown Cooling System.

'5

".82 6.0 c i zou,

e GUClear OYSTER CREEK NUCLEAR GENERATING STATION PROCEDURE Standing Order 38 ReWsion No.

Reactor Low Level Alarm Response with Yarways Out-of-Service 1

3.2.2.8 Isolate each Primary Containment Penetration listed in Table 38-1 by closing at least 1

one (1) valve in each penetration.

Refer to Table 38-2 when any isolation valve in Table 38-1, or any valve specified in 1

Steps 3.2.2.1, 3.2.2.4, 3.2.2.6, and 3.2.2.7, is inoperable.

3.2.2.9 Clear the OW of all personnel and shut at least (1) one drywell airlock door.

3.2.2.10 Ensure all penetrations to Primary Containment are closed, including manways and penetration flanges.

5 n

5 N

5 i

k e

7.0 cizo.,,

Number OYSTER CREEK NUCLEAR GENERATING NUCIGar STATION PROCEDURE Standing Order 38 Revision No.

Reactor Low Level Alarm Response with Yarways Out-of-Service 1

4.0 INSTRUCTIONS FOR LOSS OF REACTOR BUILDING VENTILATION Upon loss of Reactor Building ventilation (L-4-c, L-5-c), then:

4.1 Confirmatory Actions a.

4.1.1 Check for trip of Reactor Building ventilation.

4.1.2 Check for auto-initiation of Standby Gas Treatment System.

4.2 Manual Corrective Actions 4.2.1 Attempt restart of Reactor Building vedtllation system.

4.2.2 If Reactor Building ventilation cannot be restored, initiate Standby Gas Treatment System.

4.2.3 If Standby Gas Treatment cannot be initiated, comply with Technical Specification 3.5.b.la, b, c, d, and e.

5.0 INSTRUCTIONS FOR LOSS OF POWER TO MCC IB21A, 1821B or CORE SPRAY FILL PUMPS Upon loss of power to motor control centers IB21A, 1821B or loss of any Core Spray Fill Pump, then:

5.1 Manual Corrective Actions 5.1.1 If the Core Spray fill Pump (s) is not restarted within 5 minutes, start a Core Spray Main Pump in any system that does not have a fill pump operating. DO NOT INJECT INTO THE RPV UNLESS REQUIRED BY THIS STANDING ORDER OR g

EMERGENCY OPERATING PROCEDURES.

5.1.2 Continue to operate the Core Spray Main Pump until power 5

is restored to the Core Spray Fill Pump.

=

2 k,

A i s n 82 8.0 c,2 a u )

(UCl88r YSTER CREEK NUCLEAR GENERATING STATION PROCEDURE Standing Order 38 ReWsi n No.

Reactor Low Level Alarm Response with Yarways Out-of-Service 1

TABLE 38-1 CONTAINMENT PENETRATIONS AND ISOLATION VALVES Penetration Isolation Valve (s)

RBCCH Inlet V-5-147 RBCCH Outlet V-5-166, -167 Reacto.- Head Cooling V-31-2 V-22-1, -2 DHEDT PASS Liquid Poison Sample Valve V-40-6 DH Sump V-22-28 -29 Torus to Reactor Building V-26-16, V-26-15' Vacuum Breakers V-26-18, V-26-17' TIP System TIP Machine Ball Valves TIP N Purge V-23-70 2

H Sensing Line V-38-37, -38, -39, -40, -44, -46 2

Recirc Loop Sample Line V-24-29, -30 Torus 02 Sample Line V-38-22. -23 DH 02 Sample Line V-38-9, -10 DH Vent V-27-1,

-2, V-23-21, -22 DH Purge V-27-3,

-4, V-23-13, -14, -17. -18 2_

Torus Vent V-28-17, -18, -47 g

Torus Purge V-23-15, -16. 20 9

g Torus Particulate Monitor V-38-16 -17 h

' NOTE:

Tied open for ventilation. Untie and close if V-26-16 (-18) cannot be isolated, if required.

A000105011 82 (120*P>

El-1

""*D" Nuclear OYSTER CREEK NUCLEAR GENERATING STATION PROCEDURE Standing Order 38 Revision No.

Reactor Low Level Alarm Response with Yarways Out-of-Service 1

TABLE 38-2 CONTAINMENT ISOLATION VALVES NOT IN SERVICE AND RESPECTIVE REDUNDANT ISOLATION VALVE VALVE 005 PENETRATION REDUNDANT VALVE DATE/ TIME RETURNED

s 5

l A

i s n.82 cizo E2-j

.