9 August 5, 1994 Docket No. 50-335 Distribution We J. Norris PDII-2 RF OGC S. Varga ACRS (10)
Mr. J. H. Goldberg G. Lainas D. Verrelli, RII President - Nuclear Division H. Berkow Florida Power and Light Company E. Tana Post Office Box 14000 Juno Beach, Florida 33408-0420 4
Dear Mr. Goldberg:
SUBJECT:
INSERVICE TESTING PROGRAM RELIEF REQUEST PR ST. LUCIE PLANT, 3
UNIT 1 - TAC NO. M88783 By letter dated January 7, 1994, Florida Power & Light Company (FPL) submitted modified Relief Request PR-12. FPL also informed the staff that Relief Request PR-13 was deleted following further evaluation by the licensee. PR-12 had been previously granted in NRC's Safety Evaluation (SE) dated January 29, 1993, on an interim tasis to allow FPL to further review the basis for relief.
The revised relief request containing additional information to support the FPL's proposed alternate method of testing is granted. Pursuant to 10 CFR 50.55a(3)(ii) the staff has authorized the proposed alternate testing based on a finding that compliance with the code would result in hardship or unusual difficulty ~without a compensatory increase in the level of quality and safety.
j Our evaluation is contained in the enclosed SE.
Sincerely, (Original Signed By)
Jan A. Norris, Sr. Project Manager i
l Project Directorate II-2 Division of Reactor Projects - I/II j
Office of Nuclear Reactor Regulation
Enclosure:
As stated cc w/ enclosure:
See next page
- Previously Concurred 0FC LA:POII-2 PMMd Mh-2 OGC*
NAME DunningtM JNirNsk bcNek MYoung DATE 08/6/94 08 /Y/94 k 08 / 6 94 08/03/94 0FFICIAL RECORD COPY FILENAME: G:\\88783.JAN Y ~97 ggggg q, *SlQ / 4 73c gg '
.i l <.
Mr. J. H. Goldberg Florida Power and Light Company St. Lucie Plant 1
cc:
Jack Shreve, Public Counsel Mr. Bill Passetti Office of the Public Counsel Office of Radiation Control c/o The Florida Legislature Department of Health and 111 West Madison Avenue, Room 812 Rehabilitative Services-Tallahassee, Florida 32399-1400 1317 Winewood Blvd.
Tallahassee, Florida 32399-0700 Senior Resident Inspector St. Lucie Plant Regional Administrator, RII U.S. Nuclear Regulatory Commission U.S. Nuclear Regulatory Commission 7585 S. Hwy AIA 101 Marietta Street N.W., Suite 2900 o nsen Beach, Florida 34957 Atlanta, Georgia 30323
~
Mr. Joe Myers, Director Mr. H.' N. Paduano, Manager Div. of Emergency Preparedness Licensing & Special Programs Department of Community Affairs Florida Power and Light Company a
j 2740 Centerview Drive P.O. Box 14000 j
Tallahassee, Florida 32399-2100 Juno Beach, Florida 33408-0420 Harold F. Reis, Esq.
D. A. Sager, Vice President Newman & Holtzinger St. Lucie Nuclear Plant 1615 L Street, N.W.
P.O. Box 128 Washington, DC 20036 ft. Pierce, Florida 34954-0128 1
John T. Butler, Esq.
C. L. Burton Steel, Hector and Davis Plant General Manager 4000 Southeast Financial Center St. Lucie Nuclear Plant 1
Miami, Florida 33131-2398 P.O. Box 128 ft. Pierce, Florida 34954-0128 Mr. Thomas R.L. Kindred i
County Administrator i
St. Lucie County 2300 Virginia Avenue l
Fort Pierce, Florida 34982 i
Mr. Charles B. Brinkman, Manager Washington Nuclear Operations i
ABB Combustion Engineering, Nuclear Power 4
12300 Twinbrook Parkway, Suite 330 l
Rockville, Maryland 20852 4
4 I
t 4
-,,.y
--