ML20138E214

From kanterella
Jump to navigation Jump to search

Forwards Safety Evaluation Granting Relief from ASME Code Section XI Requirements Re Repair of ASME Class 1,2 or 3 Structures,Per 10CFR50.55a(g)(6)(i).SALP Input Encl
ML20138E214
Person / Time
Site: Saint Lucie 
Issue date: 10/04/1993
From: Strosnider J
Office of Nuclear Reactor Regulation
To: Berkow H
Office of Nuclear Reactor Regulation
Shared Package
ML20136C539 List: ... further results
References
FOIA-96-485 TAC-M87217, NUDOCS 9310130445
Download: ML20138E214 (3)


Text

. _ _ _ _

r<

.fAug g'*$

e a

UNITED STATES NUCLEAR REGULATORY COMMISSION wasuiucion o.c. 2osusmoi W E4 19m MEMORANDUM FOR:

Herbert N. Berkow, Project Director 4

Project Directorate 11-2 Division of Reactor Projects I and II FROM:

Jack R. Strosnider, Chief Materials and Chemical Engineering Branch Division of Engineering

]

i

SUBJECT:

SAFETY EVALUATION REPORT OF THE FLORIDA POWER AND LIGH REQUEST FOR RELIEF TO ALLOW A NON-CODE REPAIR OF THE SAINT LUCIE 1 REFUELING WATER TANK t

Plant Name:

Saint Lucie Unit 1 Utility:

Florida Power and Light Company Docket No.:

50-335 t

TAC No.:

M87217

)

License Status:

Operating i

Responsible PD:

PD II-2 Review Branch:

Materials and Chemical Engineering Branch Review Status:

Complete On July 30, 1993 the staff of the Florida Power and Light Coepany (FPL, the licensee), submitted a request for relief from the American Society of Mechanical Engineers (ASME) Code,Section XI requirements regarding repair of ASME Class 1, 2, or 3 structures.

The licensee seeks to perform a temporary non-ASME Section XI repair of the Saint Lucie Unit I refueling water tank (RWT), an ASME Code Class 2 structure. The FPL staff discovered a few weeks earlier that the bottom plate of the tank contained a small pinhole leak.

As detailed in the attached safety evaluation the staff has determined that code repair requirements in this case are impractical, as defined under the provisions of 10 CFR 50.55a(g)(6)(1), and that granting of the requested relief is authorized by law and will not endanger 1tfe or property or the common defense or security and is otherwise in the public interest, given due consideration to the burden upon the licensee and facility that could result if the code requirements were imposed on the facility.

Therefore, pursuant to 10 CFR 50.55a(g)(6)(1), relief is granted until the next schelduled refueling outage for the St. Lucie Unit I factitty, upon which the leaking portion of the RWT is required to be repaired or replaced in accordance with the appropriate provisions of the ASME Code,Section XI.

fe9 ggo ns w NBC HLE CENTER COPY nr x

A

i l

o

'4 H. N. Berkow L Our evaluation is submitted as Enclosure 1 and our input to SALP as.

We consider our efforts on this TAC to be complete.

Jack Strosnider, Chief Materials and Chemical Engineering Branch' Division of Engineering

(

l

Enclosures:

l As stated L

cc:

J. A. Norris l

DISTRIBUTION:

Central files EMCB RF l

GHornseth LBanic JMedoff i

i RAHermann

  • SEE PREVIOUSE CONCURRENCE DE:EMCB DE:EMCB DE:EMC l

l-

  • JMedoff:ja
  • RAHermann JRStros ider 9/15/93 9/21/93 l0/4/93 0FFICIAL RECORD COPY WP FILENAME: G:\\MED0FF\\STLUCIE2.RW1 l

I Ii l

s.

d t

4

. s H. N. Berkow t Our evaluation is submitted as Enclosure 1 and our input to SALP.as j.

We consider our efforts on this TAC to be completf.

4 4

Jack Strosnider, Chief.'

l Materials and Chemical Engineering Branch Division of Enginee' ring

Enclosures:

As stated cc:

J. A. Norris I

DISTRIBUTION:

s Central files EMCB RF GHornseth j

LBanic 2

JMedoff j

RAHermann

. }I CONCURRENCE DET:EMC

/ET:EM j<

EMCB:C PR JHedoff RAHermann JRS" osnider L

n ham f/4/9 pl/93

/93

/ /93 0FFICIAL RECORD COPY WP FILENAME: G:\\MED0FF\\STLUCIE2.RWT

/

.