Part 21 & Final Deficiency Rept,Item 221 Re Loose Parts on Anchor Darling Check Valves.Initially Reported on 851025.Set Screws Inspected & Tack Welded to Prevent Loosening in 12 Valves
ML20137Z967
Person / Time
Site: Harris 
Issue date: 11/22/1985
From: Watson R
CAROLINA POWER & LIGHT CO.
To: Grace J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
CON-NRC-401, REF-PT21-85, REF-PT21-85-479-000 221, NCR-401, PT21-85-479, PT21-85-479-000, NUDOCS 8512110464
Download: ML20137Z967 (4)


Text

-

g s 1

~

CP$L Caro,ligPoNAf & Light Company

@s-SHEARON HARRIS NUCLEAR PROJECT P. O. Box 165 New Hill, North Carolina 27562 NOV 2 21985 File Number: SliF/10-13510E NRC-401 Letter Number: HO-850473 (0)

Dr. J. Nelson Grace United States Nuclear Regulatory Commission Region II 101 Marietta Street, Northwest (Suite 2900)

Atlanta, Georgia 30323 CAROLINA POWER & LIGHT COMPANY SHEARON HARRIS NUCLEAR POWER PLANT 1986 - 900,000 KW - UNIT 1 ANCHOR DARLING CHECK VALVES - LOOSE PARTS, ITEM 221

Dear Dr. Grace:

1 Attached is our final report on the subject item which was deemed j

reportable per the provisions of 10CFR50.55(e) and 10CFR, Part 21 I

on October 25, 1985. With this report, Carolina Power & Light Company considers this matter closed.

j i

If you have any questions concerning this matter, please do not hesitate to contact me.

i Yours very truly, y RJ A. W)

~

' Vice President Shearon Harris Nuclear Power Plant MW:cci Attachment cc: Messrs. C. Maxwell (NRC-SHNPP)

J. M. Taylor (NRC) hhh kD

[

K S

NBI-OS1 g

1 617 j

s CAROLINA POWER & LIGHT COMPANY SHEARON HARRIS NUCLEAR POWER PLANT UNIT 1 FINAL REPORT ANCHOR DARLING CHECK VALVES - LOOSE PARTS ITEM 221 NOVEMBER 20, 1985 REPORTABLE UNDER 10CFR50.55(e) and 10CFR21 i

i i

IBMD-WKCB01-OS4

i

Subject:

Shearon Harris Nuclear Power Plant, Unit No. 1, 10CFR50.55(e) and 10CFR, Part 21, reportable deficiency. Check valves supplied with internal parts which may come loose and cause loss of operability.

Item:

ASME Code Class 2 and 3 and non-nuclear check valves supplied under Purchase Order NY-435013.

Surplied By:

Anchor Darling Valve Co., 701 First Street, Williamsport, PA 17701 Nature of Deficiency:

Site Nonconformance Report-85-2003 documents that 150 and 300 pound pressure class swing check valves utilize a set screw in the hinge support for the purpose of keeping the hinge pin from rotating.

Also, this set screw limits lateral movement of the pin which, if loose, could allow the hinge support and disc to become separated from the valve bonnet.

Date Problem Occurred:

Site Nonconformance Report-85-2003 was written October 9, 1985 documenting the condition.

Date Problem Reported:

On October 25, 1985, Mr. K.V. Hate' notified the NRC (Mr. F. Cantrell) that the item was reportable per the provisions of 10CFR50.55(e) and 10CFR, Part 21.

Scope of Problem:

Twelve (12) ASME Code Class 2 and 3 check valves and twenty-seven (27) non-nuclear check valves.

Safety Implication:

There are one (1) each of these valves upstream of the A and B safety train containment spray pumps.

Ingestion of the loose parts into the pumps could cause loss of both containment spray pumps.

Reason Deficiency is Reportable:

Same as " Safety Implication" above:

IBMD-WKCB01-0S4 1

,.)

Corrective Action:

The set screws have been inspected and tack welded as required to prevent loosening in the twelv-)

(12) ASME Code Class 2 and 3 valves. The twenty-seven (27) non-nuclear valves have also been inspected and corrected with the exception of one

' (1). The remaining valve is located in a system where loose parts and operability are not a safety consideration. Repair of this valve is scheduled for a window in pre-op testing. With the actions completed as stated above, this item is considered resolved.

IBMD-WKCB01-OS4 2