Text

j' E(ci$

\\

FEB 111996 Carolina Power and Light Company -

W TN: Mr. E. E. Utley.

Senior Executive Vice President Power Supply and Engineering and Construction P. 0. Box 1551 Raleigh, NC 27602 Gentlemen:

I

SUBJECT:

CONFIRMATORY MEASUREMENT RESULTS, DOCKET NOS. 50-325 AND 50-324 As part of the NRC Confirmatory Measurements Program, spiked liquid samples were sent on July 22, 1985,- to your Brunswick facility for selected radiochemical analyses. We are in receipt of your analytical results transmitted to us by.your

~

letter dated September 11, 1985. Comparison of your results to the known values are presented in Enclosure I for your information. The acceptance criteria for the comparisons are listed in~ Enclosure 2.

In our review of these data all comparative results were in agreement.

These data should be reviewed in greater detail by cognizant staff members for any significant trends in the data among successive analyses. Any biases noted may be -indicative of a programmatic weakness and attention should be given to determine reasons for such biases.

.These results and any results from previous years pertaining to these analyses will be discussed at future NRC inspections.

Sincerely, Vincent W. Pan:1 era, Chief Reactor Projects Branch 2 Division of Reactor Projects

Enclosures:

1.

Confirmatory Measurement Comparisons 2.

Criteria for Comparing Analytical Measurements j w/ encl:

c W. W. Howe, Vice President

. Brunswick Nuclear Project W. R. Dietz, Plant General Manager t

bec w/ encl:

I ptRC Resident Inspector 8602180122 860211 Document Control Desk gDR ADOCK 0 324 State of North Carolina RII I

RII NA-

]S! moi SAdamovitz e

Collins rec.F Fredrickson Ot/4/86

/86 02/[/86 Ot/II/86 01/ /86 c2

.e l

l

\\

\\

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 25pt

= _,. _., _

4 1

~

ENCLOSURE 1 CONFIRMATORY MEASUREMENT COMPAR! SONS OF H-3, FE-55.~ SR-89, AND SR-90 ANALYSIS FCR THE BRUWNSWICK NUCLEAR. PLANT ON SEPTEMBER 11, 1985 Isatope

  • Licensee NRC ResoIution Ratio Comparison (uCi/ unit)

(uCi/unitl' (Licensee /NRC)

H-3 3.12 E-5

.2.8310.06 E-5 47 1.10 Ag reement Fe-55 9.05 E-6 9.9010.20 E-6 50 0.91 Agreement '

S r-89 1.22 E-4 1.1910.04 E-4 30 1.03 Agreement -

Sr-90 1.31 E-5 1.3110.05 E-5 26

~1.00 Ag reement 8 Average of duplicate results i

i l

l l

l l

l

'e ENCLOSURE 2 CRITERIA FOR COMPARING ANALYTICAL MEASUREMENTS This enclosure provides criteria for comparing results of capability tests and verification measurements. The criteria are based on an empirical relationship which combines prior experience and the accuracy needs of this program.

In this criteria, the judgement limits denoting agreement or disagreement between licensee and NRC results are variable. This variability is a function of the NRC's value relative to its associated uncertainty. As the ratio of the NRC value to its associated uncertainty, referred to in this program as " Resolution"1 increases, the range of acceptable differences between the NRC and licensee -

values should be more restrictive. Conversely, poorer agreement between NRC and licensee values must be considered acceptable as the resolution decreases.

2 For comparison purposes, a ratio of the licensee value to the NRC value for each individual nuclide is computed. This ratio is then evaluated for agreement based on the calculated resolution. The corresponding resolution and calculated ratios which denote agreement are listed in Table 1 below.

Values outside of the agreement ratios for a selected nuclides are considered in disagreement.

.NRC Reference Value'for a Particular Nuclide 2 Resolution = Associated Uncertainty for the Value Licensee Value 2 Comparison Ratio = NRC Reference Value TABLE 1 - Confirmatory Measurements Acceptance Criteria Resolutions vs. Comparison Ratio Comparison Ratio for Resolution Agreement

<4 0.4. - 2.5 4-7 0.5. - 2.0 8 - 15 0.6 - 1.66 16 - 50 0.75 - 1.33 51 - 200 0.80 - 1.25

>200 0.85 - 1.18