ML20137A500

From kanterella
Jump to navigation Jump to search
Forwards Enhanced Team Operational Insp Rept 50-528/85-12 on 850523-0605 & 0716.No Violations Noted
Date released: 05/30/2020 Download: ML20137A500


Observations & Comments,Initial Reactor Startup & Low Power Reactor Physics Tests,Palo Verde Nuclear Generating Station,Unit 1,NRC Region V Enhanced Insp.
ML20137A669
Person / Time
Site: Palo Verde 
Issue date: 06/21/1985
From: Peterson L
LAWRENCE LIVERMORE NATIONAL LABORATORY
To:
References
Download: ML20137A669 (5)
Forwards Observations & Comments,Initial Reactor Startup & Low Power Reactor Physics Tests,Palo Verde Nuclear Generating Station,Unit 1,NRC Region V Enhanced Insp.
ML20137A641
Person / Time
Site: Palo Verde 
Issue date: 06/28/1985
From: Peterson L
LAWRENCE LIVERMORE NATIONAL LABORATORY
To: CREWS J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
References
Download: ML20137A641 (1)
Advises That Operating Crews Observed During 850526-31 on-shift Special Insp Performed Duties in Prof Manner. Specific Items Noted During Startup & Low Power Physics Tests Encl
ML20137A617
Person / Time
Site: Palo Verde 
Issue date: 06/18/1985
From: Boegel J
Battelle Memorial Institute, PACIFIC NORTHWEST NATION
To: CREWS J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
References
Download: ML20137A617 (3)
Advises That Operating Crews Monitored During 850522-28 on-shift Special Insp Performed Duties Responsibly & Professionally.Specific Items Noted During Startup & Low Power Physics Tests Encl
ML20137A592
Person / Time
Site: Palo Verde 
Issue date: 06/06/1985
From: Gore B
Battelle Memorial Institute, PACIFIC NORTHWEST NATION
To: CREWS J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
References
Download: ML20137A592 (2)
Advises That Operating Crews Monitored During 850529-0605 on-shift Special Insp Performed Duties Correctly & in Prof Manner.Sufficient Caution & Thoroughness in Handling of Initial Power Ascension Operations Exhibited
ML20137A569
Person / Time
Site: Palo Verde 
Issue date: 06/14/1985
From: Upton J
Battelle Memorial Institute, PACIFIC NORTHWEST NATION
To: CREWS J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
References
Download: ML20137A569 (2)
Enhanced Team Insp Rept 50-528/85-12 on 850522-0605 & 0716. No Violations Noted.Major Areas Inspected:Operating Crews & Operational Support Activities During Initial Startup & Low Power Testing
ML20137A530
Person / Time
Site: Palo Verde 
Issue date: 08/06/1985
From: Bosted C, Bryan S, Crews J, Eckhardt J, Fiorelli G, Huey R, Miller L, Pate R, Polich T
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
To:
References
Download: ML20137A530 (8)
Forwards Enhanced Team Operational Insp Rept 50-528/85-12 on 850523-0605 & 0716.No Violations Noted
ML20137A493
Person / Time
Site: Palo Verde 
Issue date: 08/06/1985
From: Kirsch D
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
To: VAN BRUNT E E
ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
References
Download: ML20137A493 (1)