ML20136G680

From kanterella
Jump to navigation Jump to search
Forwards Safety Evaluation Granting Relief from ASME Boiler & Pressure Vessel Code,Section XI Requirement Re Pressure Testing of Class 2 Piping Associated W/Rcs,Per 850828 Request
ML20136G680
Person / Time
Site: Calvert Cliffs  Constellation icon.png
Issue date: 11/14/1985
From: Harold Denton
Office of Nuclear Reactor Regulation
To: Lundvall A
BALTIMORE GAS & ELECTRIC CO.
Shared Package
ML20136G686 List:
References
NUDOCS 8511220414
Download: ML20136G680 (2)


Text

. _ _ _ _ _ . _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

November 14, 1985 DISTRIBUTION:

l Docket Nos. 50-317 Docket J U es i ray G File ,

( and 50-318 NRC'PDR'~ AThadani

, L PDR '

ORB #3 Rdg l

HThompson Mr. A. E. Lundvall , Jr. OELD l

Vice President - Supply EJordan Baltimore Gas & Electric Company BGrimes P. O. Box 1475 JPartlow Baltimore, Maryland 21203 DJaffe PMKreutzer

Dear Mr. Lundvall:

ACRS +10 The NRC has provided relief from a requirement of the ASME Boiler and Pressure Vessel Code,Section XI, which BG&E has determined to be impractical in accordance with your application dated August 28, 1985.

The code relief, granted in accordance with 10 CFR Part 50, Section 50.55a(g)(6)(1),

relates to the requirement for pressure testin with the High Pressure Safety Injection (HPSI)g , Auxiliary of Class HPSI,2 and piping Lowassociated Pres-sure Safety Injection (LPSI) Loop Isolation MOVs to the Reactor Coolant System.

You have proposed acceptable, alternate testing as described in the enclosed Safety Evaluation.

We have detemined that the testing for which relief has been requested and approved is impractical and pursuant to 10 CFR 50.55a(g)(6)(1), that the granting of this relief is authorized by law and will not endanger life or property or the comon defense and security and is othersise in the public interest. In making this determination, we have given due consideration to the burden that could result if these requirements were imposed on your facility.

Sincerely, Sit ud 85 lL R.owtm Harold R. Denton, Director Office of Nuclear Reactor Regulation

Enclosure:

Safety Evaluation cc w/ enclosure See next page b h nn TW %y g

) ORB # :DL DL 0 .L :0R DD:NRR PK

[V g / /85 ttB DJa fe:dd Elfut fher @as hompson DEisenhut

$$/ /85 $/S /85 1}/J7J85 {/p85 1$/ /85 8511220414 851114 PDR ADOCK 05000317 P PDR

l Mr. A. E. Lundvall, Jr. l Baltimore Gas & Electric Company Calvert Cliffs Nuclear Power Plant cc:

Mr. William T. Bowen, President Regional Administrator, Region I Calvert County Board of U.S. Nuclear Regulatory Comission Comissioners Office of Executive Director Prince Frederick, Maryland 20768 for Operations 631 Park Avenue D. A. Brune, Esq. King of Prussia, Pennysivania 19406 General Counsel Baltimore Gas and Electric Company Mr. Charles B. Brinkman P. O. Box 1475 Manager - Washington Nuclear Operations Baltimore, Maryland 21203 Combustion Engineering, Inc.

7910 Woodmont Avenue George F. Trowbridge, Esq. Bethesda, Maryland 20814 Shaw, Pittman, Potts and Trowbridge

, 1800 M Street, NW Mr. J. A. Tiernan, Manager Washington, DC 20036 Nuclear Power Department Calvert Cliffs Nuclear Power Plant Mr. R. C. L. Olson, Principal Engineer Maryland Routes 2 and 4 Nuclear Licensing Analysis Unit Lusby, Maryland 20657 Baltimore Gas and Electric Company Room 720 - G&E Building Mr. R. E. Denton, General Supervisor P. O. Box 1475 ' Training and Technical Services Baltimore, Maryland 21203 Calvert Cliffs Nuclear Power Plant 4

Maryland Routes 2 and 4 Resident Inspector c/o U.S. Nuclear Regulatory Commission Combustion Engineering, Inc.

4 P. O. Box 437 ATTN: Mr. R. R. Mills, Manager Lusby, Maryland 20657 Engineering Services P. O. Box 500 Mr. Leon B. Russell Windsor, Connecticut 06095 Plant Superintendent Calvert Cliffs Nuclear Power Plant Department of Natural Resources Maryland Routes 2 and 4 Energy Administration, Power Plant Lusby, Maryland 20657 Siting Program ATTN: Mr. T. Magette Bechtel Power Corporation Tawes State Office Building ATTN: Mr. D. E. Stewart Annapolis, Maryland 21204 Calvert Cliffs Project Engineer 15740 Shady Grove Road Gaithersburg, Maryland 20760 Mr. R. M. Douglass, Manager Quality Assurance Department Baltimore Gas and Electric Company

, Fort Smallwood Road Complex P. O. Box 1475 Baltimore, Maryland 21203