LIQUID WASTE DISCHARGE OF 1992
- mm o EE Reference Date:
10/1/90 J
Half Life (hrs) =
106872 0
Half Life (days) =
4453 M
Old Value 04 Year Quarter Date of Discharge Gross B/G H-3 Conc.
Co40 Garn. Spec. Volume Discharged Gross B/G H-3 Co40 H-3 Conc.
Micro Ci/cc Micro Ci/cc Micro Ci/cc Gallons Micro Ci Micro Ci Micro Ci pCi/cc 1op EEo 1992 1 st 1/15/92 2.74E-07 3.47E-05 4.89E-07 3400 3.526 446.685 6293 3.74E-05 1/15/92 3.18E-07 3.78E-05 4.66E-07 1600 1.926 228.777 2.822 4.07E-05 3/17/92 1.38E-07 2.56E-05 3.52E-07 3400 1.781 329.991 4.530 2.79E-05 3/17/92 4.94E-09 2.63E-05 5.24E-07 1300 0.024 129253 2.576 2.85E-05 2 nd 5/6/92 3.37E-08 5.52E-05 3.25E-07 3450 0.440 720.309 4244 6.04E-05 5/6/92 1.39E-08 4.51E-05 6.22E-07 1450 0.076 247.604 3.414 4.94E-05 6/12/92 1.19E-07 8.19E-05 5.36E-07 2900 1.306 899.014 5.883 9.02E-05 6/12/92 1.05E-07 9.02E-05 5.77E-07 1900 0.755 648.432 4.149 9.93E-05 6/24/92 4.62E-07 1.09E-04 5.48E-07 2500 4.367 1035.995 5.185 1.21E-04 6/24/92 1.57E-07 1.13E-04 5.41E-07 2000 1.185 854.181 4.095 1.25E-04 3 rd 7/16/92 1.50E-07 128E-04 3.27E-07 3850 2.186 1869.015 4.765 1.42E-04 7/16/92 3.39E-08 128E-04 5.31E-07 1450 0.186 703.915 2.914 1.42E-04 7/22/92 7.52E-08 4.86E-05 5.24E-07 3600 1.025 662.750
-7.140 5.39E-05 7/22/92 2.35E-08 5.55E-05 5.43E-07 1400 0.125 293.886 2.875 6.15E-05 8/6/92 6.03E-08 6.92E-05 5.48E-07 3600 0.822 943.351 7.467 7.69E-05 8/6/92 9.28E-08 6.60E-05 5.24E-07 1400 0.492 349.685 2.777 7.33E-05 8/28/92 1.18E-07 7.03E-05 5.65E-07 3750 1.668 997.127 8.019 7.83E-05 8/28/92 6.11 E-08 3.40E-04 4.99E-07 1350 0.312 1737.523 2.550 3.79E-04 9/16/92 5.79E-08 4.80E-04 5.43E-07 3700 0.811 6727.434 7.604 5.37E-04 9/16/92 6.27E-08 4.54E-04 5.10E-07 1300 0.309 2236.045 2.509 5.08E-04 4 th 10/5/92 1.10E-07 6.84E-05 4.74E-07 3600 1.499 932.153 6.459 7.67E-05 10/5/92 4.31E-08 9.01 E-05 5.42E-07 1300 0.212 443255 2.667 1.01 E-04 11/9/92 7.76E-08 2.08E-04 3.99E-07 3500 1.028 2761.593 5.286 2.35E-04 11/9/92 4.85E-09 4.77E-05 5.45E-07 1400 0.026 252.656 2.888 5.38E-05 I
LIQUID WASTE DISCHARGE OF 1992 Dilution factor (cctQtr) =
2.514E+11 Quarterly Average Release Total Activity Released / Quarter for 1992 -
Based on the Ga Tech Dilution factor Gross B/G H-3 Co-60 Gross B/G H-3 Co-60 Micro Ci Moro Ci Micro Ci Moro Ci/cc Moro Ci/cc Mero Ci/cc 1st QTR 7.2573 1134.7061 16.2208 1st QTR 2.8868E-11 4.5135E-09 6.4522E-11 2nd QTR 8.1294 4405.5348 26.9713 2nd QTR -
3.2336E-11 1.7524E-08 1.0728E-10 3rd QTR 7.9342 16520.7300 48.6210 3rd QTR 3.1560E-11 6.5715E-08 1.9340E-10 4th QTR 2.7646 4389.6570 17.2993 4th QTR 1.0997E-11 1.7461E-08 6.8812E-11 Yearly Total =
26.0855 26450.6279
'109.1125 Yearly Total (Ci) =
2.609E-05 2.645E-02 1.091E-04 AVG Yearly Conc.pCi!cc=
1.166E-07 l 1.182E-04 l 4.878E-07 l l Tech Spec l pCi/cc=
3.000E-06 l 1.000E-01 l 5.000E-05 l
% Tech Spec =l 3.89 l
0.12 l
0.98 l
Quarterly Average Release Based on the NNRC quartely volume discharged
. Quartelv Volume Disharned from NNRC for 1992 Gross B/G H-3 Co-60 Mero Ci/cc Micro Ci/cc Mcro Ci/cc Gals cc 1st OTR 9.7000E+03 3.6715E+07 1st QTR 1.9767E-07 3.0906E-05 4.4181 E-07 2nd QTR 1.4200E+04 5.3747E+07 2nd QTR 1.5125E-07 8.1968E-05 5.0182E-07 3rd QTR 2.5400E+04 9.6139E+07 3rd QTR 8.2528E-08 1.7184E-04 5.0574E-07 4th QTR 9.8000E+03 3.7093E+07 4th QTR 7.4033E-08 1.1834E-04 4.6638E-07 l
l Yearly Total = l 5.9100E+04 l 2.2369E+08 l Maximum ouarterly Concentration for 1992 Gross B/G H-3 Co-60 NOTE: Total Alpha radioactivity released and average '
Micro Ci/cc Micro Ci/cc Micro Ci/cc Concentration released is < MDA ist QTR 3.1800E-07 3.7777E-05 5.2350E-07 2nd QiR 4 6150E-07 1.1284E-04 6.2200E-07 3rd QTR 1.5000E-07 4.8038E-04 5.6500E-07 r
4th QTR 1.1000E-07 2.0846E-04 5.4500E-07