_ _ _ _ _ _ _ _ _ _ _ _
LIQUID WASTE DISCHARGE 3 OF 1991 Reference Date:
10/1/90 o
C Half Life (hrs) =
106872 U
Half Life (days) =
4453 80 Old Value Year Quarter Date of Discharge Gross B/G H-3 Conc.
Co-60 Gam. Spec. Volume Discharged Gross B/G H-3 Co-60 H-3 Conc.
Micro Ci/cc Micro Ci/cc Micro Ci/cc Gallons Micro Ci Micro Ci Micro Ci pCi/cc OO 1991 1 st 1/24/91 2.91E-08 5.36E-04 9.72E-07 2720 0.300 5521.472 10.007 5.46E-04 nh[
1/24/91 8.25E-08 5.05E-04 9.72E-07 1380 0.431 2639.720 5.077 5.15E-04
$3 2 nd 4/5/91 3.30E-08 7.07E-05 5.40E-07 3300 0.413 883.365 6.745 7.28E-05 0
4/5/91 2.30E-08 5.71 E-05 2.35E-06 1500 0.130 324.092 13.342 5.88E-05 4/29/91 2.82E-08 5.20E-05 3.88E-07 2800 0.299 550.609 4.112 5.37E-05 4/29/91 1.39E-07 4.54E-05 725E-07 2500 1.315 429.522 6.860 4.69E-05 5/29/91 3.16E-08 2.12E-05 5.67E-07 2000 0.240 160.653 4.292 2.20E-05 5/29/91 6.69E-07 1.48E-04 2.97E-07 2400 6.076 1343.274 2.698 1.54E-04 6/4/91 4.51 E-09 1.77E-05 8.11E-07 2700 0.046 181.173 8.288 1.84E-05 6/4/91 1.76E-07 5.80E-05 3.94E-07 2300 1.530 505.141 3.426 6.03E-05 6/21/91 4.62E-08 2.21 E-05 1.16E-06 3300 0.577 276.240 14.489 2.30E-05 6/21/91 2.31E-08 4.88E-05 2.24E-07 1700 0.149 314.196 1.441 5.09E-05 3 rd 7/5/91 7.90E-08 8.27E-05 1.03E-06 3360 1.004 1051.465 13.099 8.63E-05 7/5/91 1.12E-07 7.65E-05 8.50E-07 1620 0.684 468.782 5.212 7.98E-05 7/18/91 4.57E-09 3.40E-05 4.19E-07 3200 0.055 412.160 5.075 3.56E-05 7/18/91 1.83E-08 4.66E-05 2.74E-07 1600 0.111 282.086 1.659 4.87E-05 7/25/91 5.81 E-08 4.35E-05 4.78E-07 3400 0.748 560.197 6.151 4.56E-05 7/25/91 7.75E-08 5.08E-05 2.70E-07 1400 0.411 269.072 1.431 5.32E-05 8/5/91 2.38E-08 5.15E-05 6.61E-07 3000 0.270 584.472 7.506 5.40E-05 8/5/91 9.50E-09 5.68E-05 4.99E-07 1300 0.047 279.396 2.455 5.96E-05 8/20/91 1.32E-06 1.58E-04 4.29E-07 3600 17.959 2151.027 5.846 1.66E-04 8/20/91 327E-08 1.63E-04 3.62E-07 1400 0.173 862.210 1.918 1.71 E-04 8/W91 5.63E-07 1.80E-05 4.54E-07 2400 5.116 163.448 4.124 1.90E-05 8/30/91 4.69E-09 4.13E-05 2.56E-07 1800 0.032 281.398 1.744 4.35E-05 9/12/91 1.01 E-07 7.85E-05 1.09E-06 2400 0.915 712.984 9.902 8.2SE-05 9/12/91 1.39E-07 8.45E-05 6.10E-07 1200 0.632 383.779 2.771 8.92E-05 9/18/91 1.75E-07 4.12E-05 2.19E-06 3500 2.324 545.422 29.012 4.35E-05 9/18/91 1.90E-08 4.07E-05 4.28E-07 1400 0.100 215.661 2.268 4.30E-05 4 th 11/11/91 6.77E-07 9.28E-05 3.53E-07 2750 7.043 965.417 3.674 9.88E-05 11/11/91 5.05E-09 9.33E-05 4.57E-07 2200 0.042 777.024 3.805 9.94E-05 12/18/91 2.37E-08 6.63E-04 2.78E-07 1600 0.144 4013.140 1.684 7.11E-04 12/18/91 2.00E-08 8.15E-04 2.91 E-07 1900 0.144 5859.932 2.093 8.73E-04 12/18/91 3.51E-08 7.38E-04 2.99E-07 1300 0.173 3632.826 1.471 7.91 E-04
_ _ - _ _ _ ~..
i
' LIQUID WASTE DISCHARGES OF 1991 Dilution factor (cc/Qtr) =
2.371E+11 -
ChladEllLAM9tEge Release Total Activity ReleasedIQuarterfor1991 Based on the Ga Tech Dilution factor Gron]
H-3 Co-60 Gross B/G H-3 Co-60 Micro Ci Micro Ci Micro Cl Moro Ci/cc Mero Ci/cc Mero Ci/cc
' 1st QTR 0.7305 8161.1920 15.0840 1st QTR 3.0810E-12 3.4421E-08 6.3619E-11 2nd QTR 10.7750 4968.2640 65.6934 2nd QTR 4.5445E-11 2.0954E-08 2.7707E-10 3rd QTR 30.5795 9223.5589 100.1727 3rd QTR 1.2897E-10 3.8902E-08 4.2249E-10 4th QTR 7.5447 15251.3387 12.7273 4th QTR 3.1821E-11 6.4324E-08 5.3679E-11 Yearly Total =
49.6297 37604.3535 193.6773 Yearly Total (Cl) =
4.963E-05 3.760E-02 1.937E-04 AVG Yearly l
Conc.pCi/cc=
1.750E-07 l 1.326E-04 ' l 6.829E-07 l l Tech Spec l pCi/cc=
3.000E-06 l 1.000E-01 l 5.000E-05 l
% Tech Spec =l 5.83 l
0.13 l
1.37 l
Quarterly Average Release Based on the NNRC quartely volume discharged 1
Na 1elv Volume Disharoed from NNRC for 1991 Gross B/G H-3 Co-60 Mcro Ci/cc Moro Ci/cc Micro Ci/cc Gals cc 1st QTR 4.1000E+03 1.5519E+07 1st QTR 4.7074E 5.2590E-04 9.7200E-07
-i 2nd QTR 2.4500E+04 9.2733E+07 2nd QTR 1.1619E-07 5.3576E-05 7.0842E-07 I
3rd QTR 3.6580E+04 1.3846E+08 3rd QTR 2.2086E-07 6.6618E-05 7.2350E-07 4th QTR 9.7500E+03 3.6904E+07 4th QTR 2.0444E-07 4.1327E-04 3.4488E-07
[ Yearly Total = l 7.4930E+04 l 2.8361E+08 l Maximum quarterly Concentrabon for 1991 Gross B/G H-3 Co-60 Micro Ci/cc Micro Ci/cc Micro Ci/cc NOTE:
Total Alpha radioactivity released and average 1st QTR 8.2500E-08 5.3632E-04 9.7200E-07
.l Concentration released is < MDA 2nd QTR 6.6890E-07 1.4787E-04 2.3500E-06 3rd QTR.
1.3180E-06 1.6271E-04 2.1900E-06 4th QTR 6.7660E-07 8.1484E-04 4.5700E-07 I
.i
. -..... -