ML20134N039

From kanterella
Jump to navigation Jump to search
Feasibility of Detecting PWR Thermal Shield Support Degradation Using Ex-Core Neutron Noise, Informal Ltr Rept
ML20134N039
Person / Time
Site: Fort Calhoun 
Issue date: 07/30/1985
From: Fry D, Sweeney F
OAK RIDGE NATIONAL LABORATORY
To:
Office of Nuclear Reactor Regulation
Shared Package
ML20134N032 List:
References
CON-FIN-B-0793, CON-FIN-B-793 ORNL-NRC-LTR-85, ORNL-NRC-LTR-85-24, NUDOCS 8509040397
Download: ML20134N039 (60)


Text

.

ORNL/NRC/LTR-85/24 Subject of this Document:

Feasibility of Detecting PWR Thermal Shield Support Degradation Using Ex-Core Neutron Noise Type of Document:

Informal Letter Report Authors:

F. J. Sweeney D. N. Fry Date of Document:

July 1985 Prepared for U.S. Nuclear Regulatory Commission Office of Nuclear Reactor Regulation under DOE Interagency Agreement 40-551-75 NRC FIN NO. B0793 s, acceptence os in.. eriiese. the put>tiener or recipieni ocknowledges the U.S. Government's right to retsin a nonesclusive, royalty-free 1.cen.e in one to on, coevrien coverine ine articie.

Prepared by.

OAK RIDGE NATIONAL LABORATORY Oak Ridge, Tennessee 37831 operated by MARTIN MARIETTA ENERGY SYSTEMS, INC.

for the U.S. DEPARTMENT OF ENERGY under i

Contract No. DE-AC05-840R21400 l

l g9040397850823 ADOCK 05000285 l

p l

PDR L

-- - ^

-m..-,,,

.=

CONTENTS PAGE 1

EXECUTIVE

SUMMARY

2 1.

BACKGROUND.

2 1

2.

OBJECTIVES................

3

)

3 SCOPE...................

3 4.

DESCRIPTION OF PLANTS AND NEUTRON NOISE DATABASE 3

5.

DATA QUALITY..................

16 6.

MODELS OF THERMAL SHIELD VIBRATION AND NEUTRON NOISE 16 6.1 FINITE ELEMENT VIBRATION MODEL..

16 l

6.1.1 Description of Models..............

19 6.1.2 Results of Vibration Model 21 6.2 NEUTRONIC MODELS....

23 7.

DATA OBSERVATIONS...

23 7.1 REACTOR A 27 7.2 REACTOR B 31 i

73 REACTOR C 36-7.4 REACTOR D 44 7.5 INTERPLANT COMPARISON 50 7.6 INTERPRETATION OF DATA.................

52 8.

CONCLUSIONS AND RECOMMENDATIONS..

54 9.

ADDITIONAL WORK NEEDED........... _.........

55 REFERENCES 4

i 4

s t

iii

-~

r

-c.... ~,,

. LIST OF FIGURES PAGE FIGURE 4.1 Location of ex-core neutron detectors at Reactor A 5

4.2 Location of ex-core neutron detectors at Reactor B 6

4.3 Location'of ex-core neutron detectors at Reactor C 7

4.4 Location of ex-core neutron detectors at Reactor D 8

4.5 Location of ex-core neutron detectors at Calvert Cliffs-1 9

6.1 Finite element model of baseline (undegraded) 17 system with thermal shield 6.2 Schematic representation of finite element models of 18 degraded thermal shield supports 7.1 Normalized cross power spectral densities,(NCPSDs) of cross core detector pair Safety A and Safety C at Reactor A for beginning of fuel cycles (BOC) 2 and 5 i

(before thermal shield removal)...

24 7.2 Coherences for cross core detector pair Safety A and Safety C at Reactor A for BOC 2 and BOC 5.........

25 7.3 Frequency evolution of the 3-Hz resonance in the NCPSD of cross-core detector pair Safety A and Safety C at Reactor A.

26 7.4 Frequency evolution of the 6.5-Hz resonance in the NCPSD of cross-core detector pair Safety A and Safety C at Reactor C..

28 7.5 Frequency evolution of the 14.1-Hz resonance in the NCPSD of cross-core detector pair Safety A and Safety C at Reactor A..

29 7.6 Coherences between cross core detector pair Control X 30 and Control Y a,t Reactor B for BOC 1 and BOC 5 7.7 Frequency evolution in the 6.5-Hz resonance in the NCPSD of cross-core detector pair Safety A and 32 Safety D at Reactor B.

7.8 Frequency evolution in the 14-Hz resonance in the NCPSD of cross core detector pair Safety A and 33 Safety D at Reactor B..........

V

e r

LIST OF FIGURES (continued) 7.9 Coherences between-cross-core detector pair Control X and Control Y below 25-Hz at Reactor B for operation with thermal shield (EOCS) and without thermal shield (EOC6)....

34 7.10 Coherences between cross-core detector pair Control X and Control Y at Reactor B below 50-Hz for operation with thermal shield (EOCS) and without thermal 35 shield (E006).

7.11 Comparison between NCPSDs for cross core detector pair NI 5 and NI 7 at Reactor C on the MOC 7 and EOC 7 (before outage for thermal shield support repair).....

37 7.12 Comparison between NCPSDs for cross core detector pair NI 5 and NI 7 at Reactor C before (MOC 7) and after (BOC 8) repair of thermal shield supports......

38 7.13 Normalized root mean square (NRMS) over 3-9 Hz versus time for dete'ctor NI 5 at Reactor C 39 7.14 NRMS over 9-12 Hz versus time for detector NI 5 at Reactor C 40 7.15 NRMS over 3-9 Hz versus soluble boron concentration at Reactor C 41 7.16 NRMS over 9-12 Hz versus soluble boron concentration at Reactor C 42 7.17 NCPSDs for cross-core detector pair Safety B and-Safety C at Reactor D on the BOC 4 and MOC 4 43 7.18 NRMS over 5-10 Hz versus time for detector Control A at Reactor D 45 7.19 NRMS over 15-19 Hz versus time for detector Control A 46 at Reactor D 7.20 Comparison of cross core NCPSDs at Reactor A and Reactor B at BOC 5 (prior to the thermal shield removal) 47 vi

'e LIST OF FIGURES (continued) 7.21 Comparison of cross-core detector coherence from Reactor A and Reactor B at BOC 5 (prior to the 48 thermal shield removal)................

7.22 Comparison of cross-core detector coherences from Reactor B (thermal shield removed) and 49 Calvert Cliffs-1 (constructed without a thermal shield)..

I r

J 4

m E

vii

e

}

e s

r I

FEASIBILITY OF DETECTING PWR THERMAL SHIELD SUPPORT DEGRADATION USING EX-CORE NEUTRON NOISE 4

I F. J. Sweeney D. N. Fry EXECUTIVE

SUMMARY

I Utilities and reactor manufacturers supplied Oak Ridge National Laboratory (ORNL) with ex-core neutron noise data on four Combustion Engineering (CE) pressurized water reactors (PWRs). Of the four plants, two had experienced severe thermal shield support degradation, and one ORNL

' plant experienced loose or missing thermal shield support pins.

I reviewed and analyzed these data in search of systematic changes in the

]

neutron noise which could indicate degradation of the thermal' shield or Its support structures.

1 Our studies have shown that degradation of thermal shield supports I

can be detected by analyzing ex-core neutron noise signatures for i

changes in the frequency of beam-mode and shell-mode type vibrations below 50 Hz. However, observations in plants with degraded thermal' shield supports as well as results from vibrational models indicate that these frequency changes may be small (<3 Hz). We also concluded from these results that support degradation probably occurred early in plant life in the two plants with severe damage.

i.

The above results indicate that neutron noise measurements must be made with sufficient care, statistical precision, and frequency resolu-tion in order to detect degradation of core internals.

Because such f

degradation may occur over either short or long time periods, periodic measurements should be made, and the results should be reviewed by personnel experienced in neutron noise analysis and interpretation.

h

s c

1.

BACKGROUND Recently, the thermal shields of two Combustion Engineering (CE)

PWRs (Reactor A and Reactor B) were found to have sustained severe damage as a result of flow-induced vibrations.

In both plants, loose parts were generated in the primary system, and at Reactor A, damage to the core support barrel (CSB) also occurred. The thermal shields of these two plants have since been removed. At Reactor C, also a CE PWR, several pins used to support the thermal shield were found to be miss-ing, although-no damage occurred to the thermal shield or core barrel.

Loose thermal shields have also occurred in three Babcock and Wilcox (B&W) PWRs (Oconee-1, -2, and -3) due to loose lower support bolts, and in a Westinghouse PWR (Trino).

In some plants, reactor cperation without a thermal shield might not be allowed because of pressurized thermal shock (PTS) limitations.

i Because of the difficulty of inspection, a sensitive, on-line surveil-lance technique for assuring the integrity of the thermal shield, its supports, and other core internal structures would be valuable.

2.

OBJECTIVES The NRC Core Performance Branch (FIN B0793) and Office of Nuclear Regulatory Research (FIN B0191) have jointly sponsored a feasibility study at ORNL for PWR thermal shield vibration detection using ex-core neutron detector noise. The specific objectives of the study were a.

Obtain existing neutron noise data from PWRs that have expotuenced thermal shield degradation and from plants with similar thermal shield designs.

b.

Analyze the data and search for systematic changes in the neu-tron noise which would indicate degradation of the thermal shield or its support structures.

2

^

.o 3

3 SCOPE B

The study covered four CE plants:

Reactors A, B, C, and D.

Noise data from Calvert Cliffs-1 (a CE plant without a thermal shield) obtained through the Neutron Noise Baseline Program (FIN B0191) was also utilized for comparison. Previous studies on thermal shield vibration 8 were also utilized.

A finite detection' and Sequoyah-1 neutron noise element vibration analysis was performed on a model of a PWR in which degraded thermal shield support conditions were simulated.

4.

DESCRIPTION OF PLANTS AND NEUTRON NOISE DATABASE A short description of each plant is contained in Table 4.1.

Figures 4.1-4.5 show the locations of the ex-core neutron detectors.

Neutron noise data were obtained in two formats:

analog tape recordings and plots of spectral quantities (NPSD, NCPSD, phase, coherence) output from Internals Vibration Monitoring (IVM) systems.

Analog recordings were analyzed on ORNL's ndise analysis system. Since the plots obtained

~

from.IVM systeme varied in size and scale from plant to plant and within a plant (see Section on data quality), selected graphical data were digitized on a graphics tablet and replotted on consistent scale sizes for comparison. A description of the data provided by utilities and reactor manufacturers is given in Table 4.2.

5 DATA QUALITY The ability of noise analysts to interpret noise signatures is directly related to the quality of signal acquisition, conditioning, recording, analysis, and documentation practices.

In all cases, ORNL In had no control over one or more of these aspects of noise analysis.

the course of our interpretation efforts, deficiencies or discrepancies in the data were noted. Data discrepancies were discounted based on alternate information sources (open literature reports) or our These experience with typical neutron noise signature behavior.

discrepancies are listed by reactor type in Table 5.1.

I t

u_

.,4,

)-

e.

s Table 4.1.

Description of plants in study 1

Calvert Reactor A Reactor B Reactor C Reactor D Cliffs-1 Power [MW(e)]

810 830 790 478 845

- Coolant loops 2

2 3

2 2

Coolant pumps 4

4 3

4 4

Pump speed

-900 900 1200 1200 900 (rpm) t Thermal shield Removed

  • Removed
  • yes yes no

" Thermal shield removed after fuel cycle 5.

TThermal shield supports repaired after fuel cycle 7.

G@

4

-m.-

-.me-

---e-w,

~

5 ORNL-DWG 85-14023 O

0 NI-9 CONTROL A SAFETY 0

O O0 0

22 345 r

B S AFETY O 75 l

l O

o sum A

7 7

255o i

j

{

l i

O O

INl.ET N0ZZlf NI-10 CONTROL 0

C SAFETY 180 202 165o l

V OUTLET N0ZZLE Fig. 14.1.

Location of ex-core neutron detectors at Reactor A.

I

-,,,-,ne.,,,----,w--wr.,,,,,,,,-----,,m w-----,,,---,.-,n.----c.,-

m.en-

,,www.,,,

-c-, - - - ~~,,----s,w~-emy

^k 6

ORNL-DWG 85-14024

. j\\

~

l A SAFETY O

0 17 l

4 X CONTROL B SAFETY f

i 0 73 o

~

0 287 0

l 90 0

270 -

1 I

5 i

O O

C SAFETY l

Y CONTROL

]

[

0 107 253 i

J l

O hh LE D SAFETY 1800 l~

0 197 V

OUTLET N0ZZLE i

1 Location of ex-core neutron detectors at Reactor B.

l Fig. 4.2.

f l

i

.i

s 7

ORNL-DWG'85-14025$

LOOP 3 T C

\\

i O*

W3 357 t/Z' Ty 5

N"

~~

Conc Snovo-f.

/

~

62 1/2*

I

\\'

/

67 t/2' k

', /.

/

/

m LDOP 2

\\t A

,c.

TH 8

l*l E-~~f

~-

-h

'YP'

}

270 1

$l i

h\\

/ !/

1, 6

247 t/2'

__V 2421/2*

~

TatRMAL

$wicLD s

l 7

LOOP 2 TC I

C...

,3,,

bwrt.

I LDOPl TH 58 0*

DE TLCTOR LOC ATIONS

@ @ @ @- PCwER R At4GE EAF ETY CH A?4NELS gg

  • PCWER R ANGE Cor4T ROL CN ANNCLS Location or ex-core neutron detectors at Reactor c.

Fig, 16,3

i 8

ORNL-DWG 85-14026 D WIDC' RANGE l

D WIDE RANGE B CONTROL O O O

B SAFETY D SAFETY 90' O

O B WIDE itANGE 1.Jos 61 3 '

0 O

SPARE O

3

\\

180*

O'

=

13'

%. J '

f 0

0 O

SPARE C WIDE RANGE-0 N

O A SAFETY C SAFETY 270 i

l

)

O O

O-A WIDE RANGE 7

A WIDE RANGE A CONTROL i

Fig. 4.88.

Location of ex-core neutron detectors at Reactor D.

1 i

i

~

9 ORNL-DWG 83-11370 l

18 O OUTLET t

NOZZLE CORE SUPPORT BARREL 163 Wh\\\\

l INLET NOZZLE INLET l

NOZZLE

[

L l

@ 253'

% --27O' k

90 * -

k l

l CORE I

SHROUD 73* g

\\

INLET l

NOZZLE l

INLET f-NOZZLE

~

NN us

@ 343" I

i I

OUTLET I

NOZZLE i

O' t

Location of ex-cora neutron detectors at Calvert Cliffs-1.

Fig. 4.5 l

..___.._____....__.,.r__-,.--_.,__,._.-

..,_,,,,,.-y

.,,my.

..,_..-,r

.___,.--.m.

10 e

Table 4.2.

Data provided to ORNL for thermal shield analysis Fuel Power Bandwidth cycle level (5)

(Hz)

' Reactor C Tape recordings:

7 100 0.1 - 100 7

100 0.1 200 7

100 7' - 2K 7

100

? - 200 7

100

? - 200 7

100

? - 200 8

30

? - 200 8

48

? - 200 8

100

? - 200 8

100

? - 200 Reactor D Tape recordings:

3 100 1

- 100 3

100 1

- 100 3

100 1

- 100 j

3 100 1

- 100 3

100 1

- 100 3

100 1

- 100 3

100 1

- 100 1

4 100 1

- 100 4

100 1

- 100 4

100 1

- 100 I

4 100 1

- 100 4

100 1

- 100 Reactor At Tape recordings:

5 100 0.1 - 100 IVM plots:

2 100 2

12 12 (cross core 2

100 2

only) 3 100 2

12 12 3

100 2

12 l

4 100 2

12 4

100 2

12 5

100 2

12 l

5 100 2

,5 100 0.1 - 15 f

b i.

.m m

.m

l 11 1

Table 4.2 (continued)

Fuel Power Bandwidth cycle level (5)

(Hz) l Reactor Bt 25 IVM plots:

1 100 0

25 l

(cross-core 1

100 0

25 detector 1

100 0

25 l

only) 1 100 0

25 1

100 0

25 1

100 0

25 1

100 0

25 1

100 0

25 1

100 0

25 1

100 0

25 1

100 0

25 1

100 0

25 1

100 0

25 1

100 0

25 1

100 0

25 1

100 0

l 25 1

100 0

25 1

100 0

25 1

100 0

25 1

100 0

25 1

100 0

25 1

100 0

25 1

100 0

25 2

50 0

25 i

2 100 0

25 l

2 100 0

25 2

100 0

25 2

100 0

i 25 2

100 0

25 2

100 0

2 100 0

25 25 2

100 0

25 l

2 100 0

l 2

100 0

25 25 i

i 2

100 0

2 100 0

25 25 2

100 0

25 2

100 0

25 l

2 100 0

25 t

2 99 0

i 3

50 0

a 25 l

3 100 0

l

12 o

Table 4.2 (continued)

Fuel Power Bandwidth cycle level (5)

(Hz) 25 3

100 0

25 3

100 0

25 3

100 0

25 3

100 0

25 3

100 0

25 3

100 0

25 3

100 0

25 3

100 0

25 3

100 0

25 3

100 0

25 3

100 0

25 3

100 0

25 3

100 0

25 3

100 0

25 3

4 50 0

25 4

100 0

25 4

100 0

25 4

100 0

25 4

100 0

25 4

100 0

25 4

100 0

25 4

100 0

25 4

100 0

25 4

100 0

25 4

100 0

25 4

100 0

25 4

100 0

25 4

100 0

25 4

100 0

25 5

100 0

25 5

100 0

25 5

100 0

25 5

100 0

25 5

100 0

25 5

100 0

25 5

100 0

25 5

100 0

25 5

100 0

50 i

5 100 0

50 5

96 0

u

r.

13 Table 4.2 (continued) s.

Fuel Power Bandwidth cycle level (5)

(Hz) 25 6

83 0

50 6

100 0

50 6

100 0

25 6

100 0

50 6

100 0

50 6

100 0

50 6

100 0

50 6

100 0

'7 indicates value unknown.

TIVM data analysis bandwidth only.

Amplifier and filter settings unknown.

.o e

8

s 14-E l

Table 5.1.

Data discrepancies and deficiencies Reactor Data format Discrepancy or deficiency Reactor A Tape Detectors Safety A or Safety C mislabeled IVM Cross-core detectors only Reactor B IVM Drawing of ex-core detector locations incorrect.

Inconsistent plot scales.

Mislabeled plot units.

Probable incorrect data normalization.

Possible low signal dynamic range.

Amplifier bandwidth unknown. Cross core detectors only.

1

-Reactor C Tape High pass filter setting not recorded on some runs.

Isolation amplifiers gain discrepancy on some runs.

Reactor D Tape Likely tape recorder speed variation during recording or copying process, i

4

s 15,

Data quality is also determined by the statistical uncertainty in e

analysis results. The IVM data provided by utilities and reactor manu-The facturers were typically analyzed using only 50 ensemble averages.

resulting statistical uncertainty in a single frequency estimate of a power spectral Jensity (PSD) is approximately 145 of the value at the 1 standard deviation confidence level. Statistical confidence in a

cross-spectral quantities (phase and cross power spectral densities) are not known at present since uncertainty in these values are dependent upon both the number of ensemble averages and the coherence between the For 50 ensemble averages, coherences must exceed 0.06' to be signals.

considered statistically significant.

Statistical confidence and frequency resolution also determine the uncertainty of resonant frequencies in the spectra.

In general, broader resonances with higher statistical uncertainty in their amplitude and frequency resolution will lead to lower confidence in determining the actual center frequency of the resonance.

I

l l-16 I

l

}

l 6.' MODELS OF THERMAL SHIELD VIBRATION AND NEUTRON NOISE 6.1 FINITE ELDENT VIBRATION MODEL 6.1.1 Description of Models i

r Five finite element models of the reactor core and core support structures for a typical PWR were studied.' Each of these models includes a half-syneetric representation of the core and core support structure systes as shown in Fig. 6.1.

The model shown in Fig. 6.1 represents the baseline case and includes the core barrel, core support shield, thermal shield, plenum and lower grid, a staulated fuel assembly representation, and a full complement of attachments between the core barrel and thereal shield.

The other four models represent variations on this baseline case, and are designed to simulate various forms of theres1 shield support degradations upper radial attachment missing over a 60' sector, no upper radial attachment, degraded lower attachment with no upper attachment, and no thermal shield. A schematto representation of these cases is presented in Fig. 6.2.

The PAFEC Qrogram for Automatto f,1 nite Element Calculations) compu-ter program was used to perfore the analysis for this study. PAFEC is a general purpose, three-dimensional linear and non linear finite element

~,

analysis progras.* The PAFEC program was used to determine natural frequenotes and normal mode shapes of the core internal structures in water for the five models presented.

'The analysis was performed on a h6W type plant because of avail-attlity of structural dotatis. While the theres1 shield supports assumed are different from those of a CE plant, we would espect the same prediated trends. Verifloation of this assumption is beyond the scope of this study.

l

17 t

ORNL-DWG 85-14027 K j k

k E

dNesar Stoca.er W

s To ELActed. W.1et.

b Nl

"'"i),$V

\\

, NW

\\%s-g

[

\\

N / )l d dott.4 S A,2241. 'N#

QL h/f s Y y'

ww l

k I

i

)'l l

"% u

.js i/

\\

/'

__ /

i rji Ing

,\\- )

~

,,h{$

\\

O AJ' W[!h i

I un ->

1x 4

Finite element model of baseline (undegraded) system Fig. 6.1.

With thermal shield.

(

l l

18 2

i ORNL-DWG 85-14028 I

1 Edesm.Tia

.I Mnse.u. ovea be Steiams do

RAsau, Sauwe W r' te omy

. R u v.a il gg, P

o r

t

.o (sea

[N l

Tiesuns h

jTm

," 3 f***

sman.

(see

  1. w.o,

saeam g tanam.g

-Em

., Fum.

fg Le es, w

l w

      • J VheoTih 48'/
l ese7 4

%es T's L N.,T;e l

i i

i ffstaus wiW Mdocep UWei TietAMAL Tdl@ 4rsoludsdf1 4

l

'R45&Li46 91sw (Lawed. 474sdadedf Este)

~

I i

l J'

  • bue.4 l

h ad o

M i

i deae Tm b

4 eus l

i i

chL l

6 1

n

?

[

i l

L

% 3nA W D4 de I W W h 4 4_

f

$ $1 tid wipe b ett0 lowed,_

im gemo wur_

l (ueuma,4tmedadeur) i Schematto representation of. finite element models of 4

Fig. 6.2.

l degraded thermal shield supports.

r 4

,.,-,.._.--,,.-g..-..-,-.,_-,----,--...,--,_-..-,,,-.,-,,n

-.,',__,---,,,,p

,~e,..,-.-..,-

m _ -_

4 19 i

I 6:12 Results of. Vibration Model

?:

r Table 6.1 presents a summary of the natural frequencies and mode

(

i i

l.

shapes of the core barrel _and thermal shield.' The fuel assembly l

The results l

I

- bending mode frequency was fixed in the model at 3.47 Ns.

predict the following behaylor of oore internals vibrations:

In the baseline (undesraded) case, the core barrel and thermal 1.

shield do not act independently (i.e., they vibrate as a unit).

As thermal shield support degradation occurs, we postulate that 2.

two processes lead to changes in the core barrel / thermal shield boas mode frequency: changes in stiffness and changes in effec-tive mass (the true mass and the added mass resulting from I

resistance of motion of a structure in water) of the combined I

system.

sach process leads to changes in the beam mode reso-nant frequency in, opposite directions.

As the thermal shield i

becomes decoupled from the core barrel due to upper attachment degradation, the core barrel / thermal shield system beooses less stiff, and the resonant frequency of the systes decreases.

When both upper and lower attschments are @ graded, the thermal shield is increasingly deocupled from the systes, reducing its l

effective mass. Tne reduction in effective mass leads to an l

increase in the beam mode resonant frequency.

3.

When both the upper and lowe attachments are degraded, indepen-dont thermal shield shell mode vibrations appear. These vibra-tions ooour at a lower frequency than the combined oore barrel /

tnerest shield systes shell mode.

'No attempt was ande to adjust the model parameters (other than the fuel assembly bending mode frequency) to produce frequenotes estohing neutron noise results. The intent of these studies was to determine, j

I qualitatively, changes in core internals vibration frequenotes resulting from thermal shield support degradation.

i i

l

r l

Summary of calculated natural frequencies and mode shapes for finite Table 6.1.

l element models of degraded thermal shield supports in a B&W reactor No upper 60* Degraded attachments, l

upper No upper Degraded lower No thermal Mode of Baseline attachments attachments attachments shield vibration (Hz)

(Hz)

(Hz)

(Hz)

(Hz) l Fuel assembly 3.47 3 47 3.47 3.47 3.47 bending

  • Core barrel and 15.17 15.12 15.03 16.28 16.30 thermal shield wo beam mode core barrel and 31.2 31.05 36.43 33 54 34.25 thermal shield l

(3 node)

Theresi shield shell modes:

3.66 1 node (oval) 22.67 10.88 2 node 24.00 22.03 3 node 1-

'This frequency was held constant for all cases considered.

t em

s 21 1

4.

Changes in the core / barrel / thermal shield beam mode frequency are small (<1.5 Hz) even for severely degraded thermal shield attachments (including the case in which the thermal shield was removed entirely).

+

It was also observed that vibrational amplitudes and mode shapes are axially dependent upon how the thermal shield is supported and where the support degradation occurs.

i 6.2 NEUTROFIC MODELS 1

Neutronic models have been developed to infer amplitudes of thermal

{.

shield or CSB vibrations from ex-core neutron noise. We reviewed

  • these models with the following results:

1.

Thermal shield and CSB scale factor

  • calculations assume that fuel vibrations do not contribute to the ex-core neutron noise.

j Experimental results do not support this assumption.

2.

Thermal shield scale factor calculations assume that the struc-ture vibrates independently of the CSB. Experimental and calcu-i lational results (see Sect. 6.1) do not support this assump-tion.

3 Scale factor calculations indicate that independent vibrations of the thermal shield produce 5005 less ex-core neutron noise than CSB motion for a given amplitude of vibration.

We conclude from these results that commonly utilized neutronic models and calculational techniques are inadequate for determining the amplitude of internals vibrations. Because of the difficulty in interpreting amplitude changes in the peutron noise we recommend' that

'The ' scale factor" is a number, usually obtained through shielding-type calculations,.which converts neutron noise amplitude to f

vibrational amplitude of a core internal structure (i.e., percentage of neutron noise per mil of vibration).

ik g

22 2

surveillance of core internals be performed by dbserving 155g tirm changes in the neutr55 ndise', combin5d with a5551drom5ter a55sdremE5ts.

Such accelerometer measurements may require optimal sensor location, mounting, and signal conditioning (which is likely beyond the capa-Other workers' have bilities of many loose parts monitoring systems).

also reached the same conclusions and have therefore installed vibration sensors on the pressure vessel upper head to supplement neutron noise measurcsents.

l i

8 f

l i

1 f

e 99 i

d.

23 7.

DATA OBSERVATIONS 71 REACTOR A At the beginning of fuel cycle 2 (BOC2), normalized power spectral densities (NPSDs) and normalized cross power spectral densities (NCPSDs) 8 three broad reso-of cross-core detectors Safety A and Safety C exhibit nances at 3 1, 6.5, and 14.1 Hz as shown in Fig. 7.1.

Coherences between cross-core detectors are high (approximately 0.8) over the 3-to 8-Hz region as shown in Fig. 7.2 and have a 180* phase relationship, which is typical of pendular (beam-mode) structural vibrations. The 14.1-Hz resonance also exhibits high cross-core i

detector coherence (0.6-0.8) but the phase is -0*, which is typical of 1

shell-mode type vibrations. The cross core coherence also displays a resonance at approximately 20 Hz, which is not clearly evident in the NCPSDat and which has -O' phases typical of shell mode vibrations.

At the BOC5 (the last fuel cycle before thermal shield damage was

' discovered), the 31-and 6.5-Hz resonances had both become sharper and had shifted to 1.5 and 7.5 dz respectively, as shown in Fig. 7.1.

Phases remained at 180* while coherences were no longer uniformly high i

over the 3-to 8-Hz range.

In this range, isolated resonances became i

visible in the coherence at 1.5, 4, and 7.6 Hz as shown in Fig. 7.2.

The evolution of changes in the frequency of the 3-Hz resonance is o

displayed in Fig. 7 3 versus the fuel cycle. Untti EOC3, this resonance

'IVM data from Reactor A is bandpassed in the 2-to 14-Hz range.

Some information in the spectra may be present at frequencies outside this range (since the analysis range was 0.3-25 Hz). This information.

however, will be heavily influenced by the signal conditioning filter characteristics. These observations are true for the analog tape data which was conditioned and analyzed over the 0.1-to 40-Hz range.

iThe resonance is more clearly visible in the tape data.

The resonance may be difficult to resolve in the IVM data due to the filter roll-off.

l

ORNL-DWG 85-14029

-6 n

1v

=

REACTO.R A

-7

=

n iy SAFETY A-C:

=

ler8 :-

/

\\,

BOC 2

=

E v

=

', / gQr 5 n

u

?

]

k 1n

~9

~

e e

v O

-10 '; l lR

,f m

u g,-

a.

',v U

T p '.

Z

-11 n

2 1v

.s,

=

r i

=

-12 n

t 'e

,.:.r.

lv r_

.. s t

E i g:.1'i

),u,13 n

~

O 5

10 15 20 25 i

4 FREQUENCY CHz)

Normalized cross power spectral densities (NCPSDs) of Fig. 7.1.

cross-core detector pair Safety A and Safety C at Reactor A for j

beginning of fuel cycles (BOC) 2 and 5 (before thermal shield removal).

1 ORNL-DWG 85-14030 i

1 REACTOR A SAFETY A-C:

.s.

, l\\

8OC2 l '

0.8 BOC 5

.j i '*l\\ :.. :

~,

/

\\

iA m

(\\

N 0.6 i m

i m

mm at j

O OA i

., l;

(

U

.? v

\\

\\

r.

l 0.2 4

'i' i

d Q ':. ?; ;~'.;'. :

\\

k u'

i 0

t 0

5 10 15 20 25 FREQUENCY CHz)

Coherences for cross-core detector pair Safety A and l

Fig. 7.2.

Safety C at Reactor A for BOC 2 and BOC 5

ORNL-DWG 85-14031 1

3.5 i

i 3.0 -

2 x

v z

REACTOR A o

SAftlY A-C i

w 2.5 -

O m

N M

a.

SA.

1 eZ 2.0 -

i Z

O i

w W

M u

s s.s -

l'l g

1.0 i

BOC2 EOC2 BOC3 EOC3 BOC4 EOC4 BOC5 MOC5 t

FUEL CYCLE Fig. 7.3 I'requency evolution of the 3-Hz resonance in the NCPSD i

of cross-core detector pair Safety A and Safety C at Reactor A.

e 4

4 1

i 27 l

decrease behaved in a manner similar to that experienced in other PWRs:

in frequehey over the fuel cycle due to fuel assembly grid spacer relax-ation and increase in frequency at the beginning of the next cycle due to new fuel being loaded. Af ter EOC3, however, the resonance continued to decrease in frequency to 1.5 Hz. This frequency is lower than that normally experienced in other PWRs.

The 6.5-Hz resonance, which is normally associated with beam mode core barrel motion and the second mode of fuel assembly vibration, was observed to increase in frequency over the first three fuel cycles (Fig. 7.4).

The largest frequency changes (6.5 to 7.7 Hz) occurred over This increase in frequency is significant since it is cycles 2 and 3 in the opposite direction expected for fuel assembly resonant frequency Changes in frequency of this resonance between the end and changes.

beginning of a fuel cycle are indicative of.either changes in fuel assen-bly vibrations excited by CSB motion (as has been observed in other PWRs) or change.s in the CSB/ thermal shield structural dynamics during refueling (as might be cadsed by thermal cycling or changes in CSB hold-down forces).

The 14.1-Hz resonance (Fig. 7.5) also showed a decrease in frequency (14.1 to 13 3 Hz), occurring primarily during the second and third fuel cycles. Unlike the 3-and 6.5-Hz resonances there was no frequency change between fuel cycles. Cross core detector phases were O' for all measurements.

7.2 REACTOR B Because the data provided ORNL were plotted on non-uniform scales (see Sect. 5), it is not possible to show evolution of NPSDs or NCPSDs.

Coherences and phases were, however, usable since gains and normaliza-tions generally do not affect these quantities. Cross-core detector coherence at BOC1 displayed high (0.8) coherence over the 3-to 8 At the region, as shown in Fig. 7.6 and had a 180' phase relationship.

i

4 ORNL-DWG 85-14032 1

7..

7.6 -

i 2

5 7.4-U Zua 8

REACTOR A El SAFtiY A-C i

u.

g 7.0 -

-z AC Z

O, 6.s -

y m

6.6 -

~

'^

BdC2 EdC2 BdC3 EdC3 BdC4 EdC4 BOC5 MdC5 FUEL CYCLE Fig. 7.4 Frequency evolution of the 6.5-Hz resonance in the NCPSD of cross core detector pair Safety A and Safety C at Reactor C.

2 0

3 t

ORNL-DWG 85-14033 14.2 14.0 -

2 i

I REACTOR A l

is.. -

SAFETY A-C y

1 W

1 3O i

W 13.6 -

}

E g

1 p

Z4 Z 13,4 -

t O

m a

m at 1

13.2 -

u u

i i

13.0 BOC2 EOC2 BOC3 EOC3 BOC4 EOC4 BOC5 MOC5 l

FUEL CYCLE i

i Fig. 7.5 Frequency evolution of the 14.1-Hz resonance in the NCPSD cf cross-core detector pair Safety A and Safety C at Reactor A.

s

,e i

l I

ORNL-DWG 85-14034 1

i REACTOR B CONTROL X-Y:

BOc1 0'8 f *:

N BOC 5

/

,5

,s

)

.., l l,,,.::-/

W

/

U i

0.6 z

,1 W

J Q

N 1)

V s

r w

i j::

w l

Ig I

j

( 3:;;l

n O

OA i

U J:s.'

i i : '.

i 0.2 P

i i.:

u

l !!, '.

t,.

1

, b I[;j'k;k,,f; k.',

f

' ' - ^ ' '

O 0

5 10 15 20 25 FREQUENCY CHz)

Fig. 7.6.

Coherences between cross-core detector pair Control X I

and Control Y at Reactor B for BOC 1 and BOC 5.

I

s e

31 BOC1, resonarces were barely visible at 14.1 or 20 Hz in the NPSDs or NCPSDs, and coherences at these frequencies were <0.4.

At the BOC5 (last fuel cycle before thermal shield support degrada-tion was discovered), the coherence in the 14-Hz region had increased to The coher-0.7 and to 0.5 in the 20-Hz region, as shown in Fig. 7.6.

ences in the 7-Hz region increased to nearly 1 and a distinct resonance could be resolved in the coherence at 3 Hz.

The resonances in these frequency ranges were always broad so that it is difficult to determine In general, the 14-Hz resonance decreased to their exact frequency.

-13 Hz and the 6.3-Hz resonance increased to -7.0 Hz as shown in Figs. 7.7 and 7.8 respectively. Phases in the 7.0-Hz range for cross-core detectors were always 180' and O' in the 14-Hz and 20-Hz regions, respectively.

4 After cycle 5, damage to the thermal shield supports was discovered.

During the outage following cycle 5, the thermal shield and its supports were removed.

During fuel cycle 6, the reactor was operated without a l

thermal shield. Significant differences can be seen in the cross-core f

detector coherences, particularly in the 10- to 25-Hz range, as shown in During fuel cycles 5 and 6, signal conditioning and analysis Fig. 7.9.

These were expanded to include the 25-to 50-Hz frequency range.

results, presented in Fig. 7.10, show that significant changes occurred 4

in the cross-core detector coherences above 25 Hz (note that the high

)

l coherence appearing at 40 Hz is most likely due to 60-Hz electrical

~~

noise aliased by the 100-Hz sampling rate employed in the analysis).

l' 7.3 REACTOR C During a refueling outage at the EOC6, two upper thermal shield positioning pins were found to be dislodged, and a third pin was found j

These pins, along with others, were either replaced or tightened loose.

We received neutron noise tape recordings at the EOC7 refueling outage.

made on 6 occasions previous to the refueling outage and on 5 occasions following repairs.

l

)

t

.y.--

y

.r-,

w

.---y-,m,

--y

.I

~.

ORNL-DWG 85-14035 s.o Nr v

7.5 -

y y

Z m

a 3

O W

7.0 -

m REACTOR B g

SAH-TY A-D z

Z O

6.5-u>

us i

=

i d Nodo@godoD d OokOd g

g g

g gO gO g

%O FUEL CYCLE Fig. 7.7'.

Frequency evolution in the 6.5-Hz resonance in the NCPSD

.~

of cross-core detector pair Safety A and Safety D at Reactor B.

l

ORNL-DWG 85-14036 15.0 9

x

%J

~

REACTOR B 14 5 -

U SAFETY A-D Z

L1J D

O W

14.0 -

m O

LA.

Z Z

O 13.5 -

M LLJ N

i I

13 0 h

h h

i FUEL CYCLE Fig. 7.8. ' Frequency evolution in the 14-Hz resona, ce in the NCPSD n

i' of cross-core detector pair Safety A and Safety D at Reactor B.

j

ORNL-DWG 85-14037 1

i b..

REACTOR B CONTROL X-Y:

\\ ;(

0.8 l-[ THERMAL SHIELD 1.l', )

1:

NO SHIELD w

U l

')

l i

0.6 i

z w

ae m

w l

h.-

3-N O

0.4 l

v r

1

~i i

l 1 i

\\\\ (

{

'j j

. (

c O

0 5

10 15 20 25 FREQUENCY CHz)

Fig. 7.9.

Coherence between cross-core detector pair Contral X and Control Y below 25 Hz at Reactor B for operation with thermal shield 3'

(EOC5) and without thermal shield (EOC6).

s ORNL-DWG. 85-14038 1

i i

i REACTOR B

.).. i CONTROL X-Y:

O.8 THERMAL SHIELD

! '9 ;',

l! NO THERMAL SHIELD m

l u

0.6 i

i z

m cw m

V t,

m o

0.4

',j I

z i

l U

,u,,, : :

i,,:

=,,,,,,

l 02 r

)

,, p,,

, t,.,,,,:

. g

.l.',,::,,,_h

' E/W

,i if y!i' l

0 10 20 30 40 50 4

FREQUENCY CHz)

Fig. 7.'10.

Coherences between cross-core detector pair Control X and Control Y at Reactor B below 50 Hz for operation with thermal shield.'

(EOC5) and without thermal shield (EOC6).

j

.t 36 Figure 7'.11 shows a comparison between cross-core detector NCPSDs taken at MOC7 and EOC7 (immediately prior to the refueling outage).

Only slight differences in NCPSD and NPSD magnitudes were observed between these two measurements, but no differences were observed in the A comparison between pre-and post-repair (MOC7 phases or coherences.

and BOC8 respectively) measurements shows some differences in NCPSD mag-nitudes in the 3-to 9-Hz, 9-to 12-Hz, and 30- to 35-Hz frequency ranges as shown in Fig. 7.12.

The normalized root-mean squared (NRMS) values over the 3-to 9-and 9-to 12'Hz frequency ranges are plotted against time and shown in Figs. 7.13 and 7.14 respectively. These plots show a large decrease in the NRMS after repairs to the thermal shield supports were performed When these data are plotted against soluble l

during the EOC7 outage.

boron concentration, however, the NRMS are shown to decrease monotonically with increasing soluble boron concentration as shown in Figs. 7.15 and 7.16.

No changes in phase or coherence were cbserved before and after repair of'the thermal shield.

7.4 REACTOR D In Fig. 7.17, cross core detector NCPSDs from tape recordings made on BOC4 and MOC4 are compared. Below 25 Hz, changes can be observed in The resonance both the amplitudes and the frequencies of resonances.

i centered at about 7.5 Hz displays a beam-mode type behavior, while a These resonances, large resonance at -17 Hz shows an in phase behavior.

including a low-amplitude sharp resonance at 20 Hz (which corresponds to the pump rotation speed of 1200 rpm), show decreases in frequency of

-0.5 Hz during cycle 4.

Because pump speeds are usually constant, we suspected that the observed frequency shifts we_re more likely the result To of speed degradation in the tape recording or copying operations.

confirm this hypothesis, we analyzed 60-Hz contamination on the tape The 60-Hz noise.was found to decrease to 59.5 Hz, thus recordings.

confirming our hypothesis.

l i

ORNL-DWC 85-14039 f..

-6 n

=

,V i

i i

i I

y

-7 REACTOR C

-[

Ti -

l lQ

=

NI5-N17 E t y PRE-REPAIR (MOC 7)

-a 2

C 7) lv i

.,yy PRE-OUTAGE (EO n

l

-E ln.,

i N

u a

i V

=

m O

-io

~

(n In 5

O.

Iu E

r !,'. :

u E

l R

Iv,n u,

i z

i.

r y< g<,

k

-12 4

10 r

e

=

=

s l

,, {l t

i.

l

-13 c

m i

i jy 0

10 20 30 40 50 FREQUENCY CHz)

Comparison between NCPSDs for cross-core detector pair

  • ~,,

Fig. 7.11.

NI 5 and NI 7 at Reactor C on the MCC 7 and EOC 7 (before outage for thermal shield support repair).

w

/

ORNL-DWG 85-14040

-6 10 e

E a

-7 k

]Q s,

,.' e,

REACTOR C F...

N15-N17 E':

PRE-REPAIR (MOC 7)

-8

'.'. y

/y POST-REPAIR (BOC 8) --g n

lv 7

N r

I-9 h lh l

s!

r v

2 l

m.

i O

-10 us in

')

E 1,

CL IV E

,.i,',.,,

E qi,.,.4 u

E 1

J.;

s.

,(,* :

z

-n l

e 10 t

=

e

=

5

[

I' 3 y E

u i

-12

'4 Ai 10 r

,$E s

s

',f fj I

i

-13 10 0

10 20 30 40 50 1

FREQUENCY CHz)

Fig. 7.12.

Comparison between NCPSDs for er va core detector pair NI 5 and NI 7 at Reactor C before (MOC 7) and after

8) repair of thermal shield supports, i

i

I 1

/

ORNL-DWG 85-14041 i

10 i

1 l

I

^

8-REACTOR C v

~

NI-5 I

o 3.0-9.0 Hz

-J 5

w l

k i

aZ 6-l s

i

)

4 i... i.... e... s...,.... e,,,,,,,,,,,,,,,,,,,,,,,,

N D

J F

M A

M J

J A

S l

i Fig. 7.13. Normalized root mean square (NRMS) over 3-9 Hz versus i

time for detector NI 5 at Reactor C.

[

t b

-._- =

l e

ORNL-DWG 85-14042 i

1.2 i

i i

1.0 -

^v i

Io l

M v

1 us(

. REACTOR C i

j Z

0.8 -

NI-5 9.0-12.0 Hz 0.6 i,

N D

J F

M A

M J

J A

S f

f i

I Fig. 7.14.

NRMS over 9-12 Hz versus time for detector NI 5 at

)

Reactor C.

l ORNL-DWG 85-14043 i

i 10 i

4 f

s-REACTOR C p

i i

NI-5 1

o 3.0-9.0 Hz l

3

(

1 1

m

(

cx i

l 2

6-i

?

1

.~

i I

i i

i i

i 4

0 100 200 300 400 500 600 700 l

SOLUBLE BORON (PPN0 J

Fig. 7.15.

NRMS over 3-9 Hz versus soluble boron concentration at I

Reactor C.

l

r ORNL-DWG 85-14044 1.2 i

F i

l

^

10-w no i

I M

V

(/)

~

(

REACTOR C Z

08-NI-5 9.0-12.0 Hz I

{

i L

i 0.6 i

i i

i 0

100 200 300 400 500 600 700 l

1 i

SOLUBLE BORON (PPN0 r

t i

l I

i l

Fig. 7.16.

NRMS over 9-12 Hz versus soluble boron concentration at e

[

Reactor C.

j l

(

4 I

~

ORNL-DWG 85-14045

-6 e

10 5

REACTOR D

-7 i SAFETY B-C:

s mlV r

BOC4 5

E A 2

MOC4

-a

[

i n

IV s

i 5

3 w

I

-9 f:.

1mJ s

s V

5 5

Hr/$:k O

10' i

r 4

4 u

5 L,

4 z

-ii r

i, y

10 r

10

j-g

-13 10 i

0 10 20 30 40 50 FREQUENCY CHz)

NCPSDs for cross-core detector pair Safety B and

  • ~

Fig. 7.17.

Safety C at Reactor D on the BOC 4 and MOC 4 l

i i

~

r '.

i 44 i

1 and 15' t519-Hz friquidiy raMis e

NRMS values over the 5-to 10 (Figs. 718 and 7.19 respectively) showed generally dicisai1M trindi

,l i

Without additional data, it is not possible to determine if i

with time.

4 these trends are related to burnup.

I I

I 75 INTERPLANT COMPARISON E

t f

Because of structural similarities (especially size) and the exis-

[

i l

tence of thersal shield daange, we compared the results of Reactor A i

with Reactor B.

We also compared Reactor B noise data obtained after

}

removal of the thermal ahteld with data from Calvert C11ffs-1, an The Calvert f

830 MW(e), 2-loop, CE plant without a thermal shield.

C11ffs-1 data were obtained through the NRC's baseline noise prograa f

(FIN B0191).

i l

l Figure 7.20 compares cross-core detector NCPSDs from Reactors A and j

As was j

B at the 80C5 which preceded discovery of thermal shield damage.

I discussed in Sect. 5, we postulate that the two orders of sagnitude difference between the two spectra is due to incorrect normalization of

)

From this comparison, however, it can be seen that the Reactor 5 data.

j f

the resonant frequency associated with pendular CSB motion is higher for Reactor A (7 5 Hz) than for Reactor B (7 Hz). The resonance associated l

with shell-mode vibrations is lower in frequency for Reactor A (13 Hz) i l

and sharper compared to Reactor 8 (14.5 Hz). A low-frequency resonance i

l occurs in the Reactor A data at 1.5 Hs which is not visible in the j

Reactor B data. Comparison of the coherences from the two plants f

f (Fig. 7 21) also shows this behavior. In addition, ocherences >0.4 can f

As was shown in the l

be seen in the 12-to 16-and 17-to 21-Hs ranges.

l Reactor B data, cross-core detector coherences changed significantly in t

j the 10- to 20-Hs range when the theresi shield was removed. Figure 7.22 l

l shows a eosparison of the cross-oore detector ocherences between Calvert l

l C11rfs-1 and Reactor B without its therest shield. The coherences are Limilar below 25 Hs, although the Reactor 5 and Calvert Cliffs data i

l exhibit slight differences in the 12-to 15-Hs range.

i f

r f

I I

i

ORNL-DWC 85-14046

~

2.6,

e i

2.6 -

REACTOR D

^

CONTROL A

'o 5.0-10.0 Hz i

e m

v 2.4 -

j l

vi m

j l

M Z

2.2-2.0

.........r...

M J

J A

S O

N D

J FM A

M J

J Fig. 7.18.

NRMS over 5-10 Hz versus time for detector Control A at i

Reactor D.

l

Om-M 85-14047 1.2 1.0 -

l REACTOR D

^wi CONTROL A 15.0-19.0 Hz 0.8 -

i v

m

.t

=

i z

0.6 -

t m

i l

t i

[

i 0.4

....,....r...i........,...

.....................,...i..........

M J

J A

S O

N D

J F

M A

M J

J l

i

-i l

Fig. 7.19., NRMS over 15-19 Hz versus time for detector Control A J

l at Reacter D.

l o

1 m

I

,.-m.

m

ORNL-DWG 85-14048

-6 n

lu

=

FUEL CYCLE 5:

-7 REACTOR A

]

nlV I

"/ REACTORB l

=:

-s 10 i

r

=

n

=

N

?.

I

  • m), .,,

N g

ly g-

-v O

-jo

-=

lI')

(n

~

u a.

v l'

-1 lv,1 Z

3 2

r

=.

s

.=

.n

-12 10 1

r

=_

-13 10 O

5 10 15 20 25 i

FREQUENCY CHz)

Fig.'7.20.

Comparison of cross-core NCPSDs at Reactor A and Reactor B at BOC 5 (prior to the thermal shield removal).

i

ORNL-DWG 85-14049 1

i.

. ~ ~

BEGINNING OF CYCLE 5

'A REACTOR B. CONT X-Y

,.- REACTOR A SAFETY A-C 0.8

. / .

i

)

m i

l 0.6 -] i.

l $ h t

m

@: d )!

s s

O cx n

r l.r,.

m aI 1 i

I i

O DA -i (i lI

l v

t

. e,

....),,...,..

. /

.i 0.2

)::::

x:

.l '.

1 q.

0 0

5 10 15 20 25 FREQUENCY CHz)

Fig.i.21.

Comparison of cross core detector coherer.ce from Reactor A and Reactor B at BOC 5 (prior to the thermal shield removal).

ORNL-DWG 85-14050 1

i i

i l

NO THERMAL SHIELD

.i);l l, 0.8 SAFETY A-C:

I N CALVERT CLIFFS-1 i d:'i REACTOR B tu M

0.6 -l I

w

)

cw m

l:

.?

I f:

j I

i O

0.4 -i; i,:

U

)

: 1..:

)

,a 0.2 r.l h<:

h.
:

.l l,::,

,si i

l l

..,.,; d:.i: :

:s u

5.,

s 4,

.s

=

3)"'

.M,ji:j,,' :,.j;,,

'..I 's !;;,Lpf( t j

0 10 20 30 40 50 FREQUENCY CHz)

Fig. 7.22.

Comparison of cross-core detector coherences from Reactor B (thermal shield removed) and Calvert Cliffs-1 (constructed without a thermal shield).

'i

s 50 7.6. INTERPRETATION OF DATA Based on the previously discussed observations and calculations, and our experience with the behavior of neutron noise in other plants, wt made the following interpretations:

1.

Reactor A and Reactor B neutron noise data exhibit frequency shifts in the resonances associated with CSB, thermal shield, and fuel assembly structures.

2.

These changes are abnormal when compared to other plants, with or without thermal shields over a fuel cycle; specifically, Sequoyah* and Calvert Cliffs.'

3.

The observed trends in the experimental data (increasing CSB beam mode frequency and decreasing shell mode frequencies) are predicted by finite element model calculations when degraded thermal shield supports are assumed.

4 Reactor A exhibited larger changes in resonant frequencies than Reactor B indicating a greater change in structural dynamics prior to discovery of thermal shield damage.

5.

Reactor A data exhibit a low frequency resonance which may be the result of decoupled CSB and thermal shield motions. Since thermal shield vibrations are unlikely to directly increase neutron noise, this resonance might be the result of thermal shield impacting on the CSB.

6.

Reactor B data exhibit growth in cross-core detector coherences at two shell mode frequencies indicating increased stimulation of. CSB/ thermal shield resonances or a significant change in their preferential direction of vibration.

7.

The greatest changes in resonant frequencies or detector coher-ences occurred during the first or second fuel cycle of both Reactor A and Reactor B.

Therefore, we hypothesize that loosening of the thermal shield supports occurred early in plant life in both cases.

i l

i l

I

. s o

51 8.

When the thermal shield was removed from Reactor B, the noise

~

signatures became similar to those from Calvert Cliffs-1, a plant constructed without a thermal shield.

We believe that the small amount of data (<1 fuel cycle) from 9.

Reactor C and Reactor D is inadequate to confirm or deny problems in the CSB or thermal shield supports at these plants.

Comparison would have to be made with data taken early in plant life. Furthermore, we believe there is insufficient evidence from Reactor C to indicate that the changes in neutron noise observed after thermal shield support repair are solely attributable to that repair.

4 9

De a

h i

~

52.

,e t

8.' CONCLUSIONS AND RECOMMENDATIONS I

As a result of this study, the following conclusions are drawn:

1.

Thermal shield support degradation at Reactors A and B manifested itself in the ex-core neutron noise spectra.

2.

The degradation was apparent from changes in frequency of struc-tural vibration resonances or changes in cross core detector i

coherence.

3 The observed frequency changes in the neutron noise resonances of Reactors A and B were similar to those predicted b'y finite element structural models of degraded thermal shield supports.

4.

Degradation of thermal shield supports at Reactors A and B probably started early in plant life, i

As a result of this study we make the following recommendations for early detection of thermal shield support degradation:

l-1.

Surveillance of the ex core neutron noise should cover the j

0- to 50-Hz frequency range.

l 2.

Four ex-core detectors, positioned approximately 90' apart, should be analyzed, including NCPSDs for all combinations of detector pairs (both cross-core and adjacent).

3 Upper and lower half detectors should be analyzed separately, since both experimental and calculated data show an axial i

dependence of internal vibrations.

4.

Interpretation of neutron noise should emphasize the frequency of resonances, and surveillance _should be performed for changes in these frequencies.

5.

Statistically significant changes or trends in the ex-core neutron noise, particularly changes in the frequency of a rescr-nance, should be considered abnormal until the cause of the change has been identified.

I-

s 53 f,

  • Ex core neutron noise should be supplemented with accelerometer j

2 6.'

measurements since chan'ges in the neutron noise amplitude may i-l be difficult to interpret. Such measurements would ideally be independent of a loose parts monitoring system (LPMS) and may require optimal sensor location (i.e., the pressure vessel head flange).

l 7.

Surveillance of the ex-core neutron noise should be performed I

periodically:

a minimum of once every three months with monthly surveillance being preferred.

8.

Plants should have a calibrated and operating LPMS. Changes in the neutron noise, preceding or existing with impacts detected by the LPMS, indicate the need for immediate diagnostic action.

A LPMS alone may not be adequate for core internals survall-lance, since significant structural degradation may have i

already occurred by the time impacts cause an LPMS alarm.

As a consequence of the data deficiencies observed in this study, we also make the followirig recommendations for a noise surveillance program:

1.

Data acquisition, analysis, and interpretation should be i

performed by personnel trained and experienced in neutron noise analysis.

2.

QA procedures should be developed to ensure that data acquisi-l tion and analysis activities are performed correctly and ade-quately documented.

j 3.

Noise analysis results should be displayed using consistent j

i plot size and scales.

4.

Preferred units for NPSD or NCPSD are volts */(unit volt de)*/

l (unit gain)/Hz (i.e.,1/Hz). -

~

i 5.

Enough data should be acquired to ensure a high degree of sta-tistical confidence in the noise analysis results. Typically, this would require,a minimum of 100 ' data block averages (no overlap processing) with a minimum sample blocksize of 1024 and spanning the 0- to 50-Hz frequency range (a minimum of 18 min of data with 30 min of data preferred).

s 54 i

9." ADDITIONAL WORK NEEDED As a result of this study, the following areas were identiffed for additional work that would improve the application and interpretation of neutron noise analysis for monitoring the condition of core intervals:

- In-core neutron noise:

Fuel assembly vibrations have been found i

to contribute to ex-core neutron noise at frequencies below 50 Hz. This contribution complicates interpretation of changes in ex-core neutron noise. The long term behavior of in-core neutron noise and its contribu-tion to ex core neutron noise should be studied from both experimental and theoretical aspects.

- Interns 1s aging and structural interactions: Postulated degrada-tion of reactor internals due to aging knd the resulting effects on the neutron noise should be studied. Such studies would include experimen-tal measurements of how structural vibrations interact to produce neu-tron noise.

- Operational and Reactor Physics Effects: Ex core neutron noise is depen' dent on thermal-hydraulic and reactor physics (burnup, soluole boron, etc.) conditions in the reactor. The dependence of the neutron noise on these factors should be studied in order to improve interpreta-tion of changes in noise asplitude.

3

- Reactor 4:

Neutron noise data should be acquired after removal of the thermal shield and compared with other plants operating without thermal shields.

- Reactor C Ndutron noise data acquisition should be continued.

Sources of changes in noise amplitude should be determined.

- Reactor D: Source of Hz resonance in the neutron noise I

should be identified.

l l

t 55 i,

N REFERENCES 1.

P. Bernard, et al., " Quantitative Monitoring and Diagnosis of French.

I PWRa' Internal Structures Vibrations by Ex-Core Neutron Noise and t

Accelerometers Analysis," Prog. Nucl. Energy 9, 465-492 (1982).-

i.

t 2.

F. J. Sweeney, J. March-Leuba, C. M. Smith, " Contribution of Fuel Vibrations to Ex-Core Neutron Noise During the First and Second Fuel Cycles of the Sequoyah-1 Pressurized Water Reactor," Proc. Fourth Specialists' Meeting on Reactor Noise (SMORN-IV), October 15-19, 1984, Dijon France.

4 4

i 3

D. N. Fry, J. March-Leuba, F. J. Sweeney, Use of Neutron Noise for j

Diagnosis of In-Vessel Anomalies in Light-Water Reactors, J.

NUREG/CR-3303 (ORNL/TM-8774), Oak Ridge National Laboratory (1984).

i i

4.

PAFEC 75 Data Preparation, PAFEC, Ltd., Nottingham, England,

-November 1978.

5.

F. J. Sweeney, "Interia Report:

Detection of Core-Barrel Motion and

[

Thermal-Shield V;4 rations Using Ex-Core Neutron Noise," letter I

report to N. N. Kondic (NRC Division of Facility Operations, l

FIN B0191) and L. L. Lois (NRC Division of Systems Integration, FIN B0777) October 1983 6.

W. Basti and D. Wach, "Expertences with Noise Surveillance Systems in German LWRs," Prog. Nucl. Energy 9, 505-516 (1982).

7.

J. P. Steelman and B. T. Lubin, " Analysis of Changes with Operating Time in the Calvert Cliffs Unit 1 Noise Signals," Prog. Nucl. Energy 1, 379-391 (1977).

i 1

I l

h

~

-