Confirms Telcon Between T Greene & B Sheron,Re Nov 1994 Plug Cracking Experience at Plant
ML20134B549
Person / Time
Site: Saint Lucie  
Issue date: 01/24/1995
From: Thadani A
Office of Nuclear Reactor Regulation
To: Newton R
WESTINGHOUSE OPERATING PLANTS OWNERS GROUP
Shared Package
ML20134B255 List:
References
FOIA-96-485 NUDOCS 9502060079
Download: ML20134B549 (5)


Text

.

n:9 E

y i

UNITED STATES 7

E NUCLEAR REGULATORY COMMISSION f

WASHINGTON. D.C. 2056tH)o01

\\

/

January 24, 1995 Roger Newton, Chairman Westinghouse Owners Group Wisconsin Electric Power Co.

231 West Michigan Street P.O. Box 2046 Milwaukee, Wisconsin 53021

Dear Mr. Newton:

This is to confirm the telephone conversatiron that Mr. Thomas Greene of the Westinghouse Owners, Group had with Dr. Brian Sheron of my staff on January 6, 1995, regarding the November 1994 plug cracking experience at the St. Lucie plant.

In particular, Mr. Greene discussed the position of licensees that are members of the Westinghouse Owners Group concerning Westinghouse Alloy 600 steam generator mechanical tube plugs and the impact of the St. Lucie event upon the Westinghouse tube plug life algorithm (ref. WCAP-12244).

The NRC staff understands that the Westinghouse Owners Group has recommended in a letter to its members the following 4 point course of action.

These items are to be pursued by the individual plants and communicated to the NRC staff by letter, no later than January 31, 1995:

1)

Identify the number of )( mechanical plugs manufactured from alloy 600 thermally treated material present in the members steam generators that have not been either changed out or repaired.

2)

Reaffirm that operation of the affected units with tha identified plugs does not represent a safety issue.

This would be based upon the members previous response to NRC Bulletin 89-01 and its supplements.

3)

Commit to evaluate and assess the impact of Addendum 3 to WCAP-12244, to be issued by Westinghouse by January 31, 1995, on the existing unit action plan for addressing mechanical plug corrosion previously provided to the NRC in response to NRC Bulletin 89-01 and its supplements.

4)

Commit to provide to the NRC a schedule and revised action plan for each affected unit to address this issue 30 days prior to the next scheduled outage.

l Y

6 O C) -(> C)D

,T U,'yp 0

\\

'""' "'~6f

...~ :,.,&' E g,,

b'(Ckh D

d

/r erso**^

{\\

s

~ _

January 24, 1995 Roger Newton l The staff also understands that the affected owners have agreed to support the above outlined approach.

l The staff finds the industry response, as detailed, is appropriately pro-active in addressing and initiating resolution of this issue. We would encourage individual licensees to inform the NRC of their plah Tf action as soon as practical in order to provide ample time for staff review and comment. Should you have any different knowledge regarding the staff understanding of the industry response, please contact Dr. Sheron of my staff at (301) 504-2722.

Sincerely, GR:CINAL SIGNED BY A.C.THADANI Ashok C. Thadani, Associate Director for Technical Assessment cc: Thomas V. Greene, Vice Chairman, W Owners Group John Selva, Chairman, B&W Owners Group John Hutchinson, Chairman, CE Owners Group Clive Callaway, NEI l

EMCB RF DOCUMENT NAME: G:\\Hornseth\\wog.ltr

  • See previous concurrence To recalve a copy of this docunent, indicate in the box CaCopy w/o attachment / enclosure EmCopy with attachment / enclosure N = No copy 0FFICE DE:EMCB*

E DE:EMCB*

N DE:EMCB*

N DdDE d h NAME GPHornseth:adl RHermann JRStrosnider knas Bhon DATE 01/12/95:jb 01/12/95 01/18/95 l/N/95

/ / /h5

$b % \\Q

/

f 0FFICE ADT:NR g

NAME AThadani y

DATE

//M/95 OFFICIAL RECORD COPY j

/

j

(,-7

'\\

l Roger Newton,

The staff also understands that the affected owners have agreed to support the above outlined approach.

U The staff finds the industry response, as detailed, is appropriately pro-active in addressing and initiating resolution of this issue. We would i

encourage individual licensees to inform the NRC of their plan of action as j

soon as practical in order to provide ample time for staff review and j

comment.

Should you have any different knowledge regarding the staff i

understanding of the industry response, please contact Dr. Sheron of my staff 1

at (301) 504-2722.

Ashol C. Thadani, Associate Director for Technical Assessment cc:

Thomas V. Greene, Vice Chairman, W Owners Group

-John Selva, Chairman, B&W Owners Group John Hutchinson, Chairman, CE Owners Group Clive Callaway, NEI I

Distribution Central File EMCB RF

.. /'

DOCUMENT NAME: G:\\Hornseth\\wog.ltr a/

  • See previous concurrence To rocsive a copy of this document, indicate in the bon CaCopy w/o attachment /en:losure E= Copy with attachment / enclosure N = No copy 1

0FFICE DE:EMcB*

E DE:EMCB*

N DE:EHCB*

N DkDE ADT:NRR 7

NAME GPHornseth:adl RHermann JRStrosnider bSheron AThadani DATE 01/12/95:jb 01/12/95 01/18/95

/ /95

/ /95 OFFICIAL RECORD COPYgc,.

5

,,4

Roger Newton The staff also. understands that the affected owners have agreed to support the above out1 ned approach.

The staff finds he industry response, as detailed, is appropriately pro-active in addresstqg and initiating resolution of this ispue. We would encourage individual licensees to inform the NRC of their plan of action as soon as practical in order to provide ample time for sfaff review and comment.

S;iould you have any different knowledge re rding the staff understanding of the industry response, please cont ct Dr. Sheron of my staff at (301) 504-2722.

I

\\shok.Thadani,AssociateDirector A

for Technical Assessment

/

/

(

Distribution Central File EMCB RF DOCUMENT NAME: G:\\Hornseth\\wog.ltr To receive a copy of this doctment, indicate in the box C= Copy w/o attacha m enclosure E= Copy with attachment / enclosure N s No copy 0FFICE DE:EMCB E

DE:EMCB N

DE:EMCBh M DD:DE NAME GPHornseth:adl RHermann M b JRStrosh BSheron DATE I /[2-/95NM l /12 95 N

I /l0 b

\\

/ /95

/ /95

/

/

OffICIALRECORD(

\\

+5'

/

January 24, 1995 Roger Newton The staff also understands that the affected owners have agreed to support the above outlined approach.

The staff finds the industry response, as detailed, is appropriately pro-active in addressing and initiating resolution of this issue. We would encourage individual licensees to inform the NRC of their plan of action as soon as practical in order to provide ample time for staff review and comment. Should you have any different knowledge regarding the staff understanding of the industry response, please contact Dr. Sheron of my staff 4

at (301) 504-2722.

t Sincerely, WCiNAL SIG ED BY A.C.THADANI Ashok C. Thadani, Associate Director l

for Technical Assessment cc: Thomas V. Greene, Vice Chairman, W Owners Group John Selva, Chairman, B&W Owners Group John Hutchinson, Chairman, CE Owners Group Clive Callaway, NEI l

Distribution Central File l

EMC8 RF l

DOCUMENT NAME: G:\\Hornseth\\wog.ltr

  • Ste previous concurrence To receive a copy of this document, indicate in the box C= Copy w/o attachment / enclosure E= Copy with attachment / enclosure N = No copy 0FFICE DE:EMCB*

E DE:EMCB*

N DE:EMCB*

N D$2DE

d. d[

NAME GPHornseth:adi RHermann JRStrosnider (ibiknas B5hon DATE 01/12/95:jb 01/12/95 01/18/95

/ /N95

/ / /h5 OFFICE ADT:NRy[-

Msg

/

a p,/p

.p g

NAME AThadani by

/ M'/95 DATE

/

0FFICIAL RECORD COPY 7

g, p

.