Text
1 l
e
/
FORM NIS.] OWNERS' DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules l
Jersey Central Power & Light Company
- 1. Owner Madison Avenue & Punch Bowl Road, Morristown, N.J.
Oyster Creek Nuclea[d$n$rNhftk**$taNEon
- 2. Plant U.S. Route 9, Forked River, N.J. 08731 (Name and Address of Plant)
- 3. Plant Unit N/A
- 4. Owner Certificate of Authonzanc,n (if required) None
- 5. Commercial Service Date 12/23/69
- 6. National Board Number for Unit 14895
- 7. Components Inspected See attached Manufacturer Component or Manufacturer or installer State or Nation Appurtenance or Installer Serial No.
Province No.
Boar o.
/
7
/
/
/
/
/
/
r
/
/
/
/
/
/
/
/
/
Note: Supplemental sheets in form of lists, sketches, or drawings may be used provided (1) size is 8% in. x 11 in.,
(2) information in items 1 through 6 on this data report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
l
)
h I
This form (E00029) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y.
10017 l
9701290334 970123 ADOCK 05000219 gDR PDR l
FORM NIS 1 (back)
- 8. Examination Dates 12/16/94 to 10/22/96
- 9. Inspection Interval from 1/1 s/92 to 3/1 A /n2
- 10. Abstract of Exan$inations. Include a list of examinations and a statement concerning status of work required for current interval.
See attached
- 11. Abstract of Conditions Noted See attached
- 12. Abstract of Corrective Measures Recommended and Taken See attached We certify that the statements made in this report are correct and the examinations and corrective mea-sures taken conform to the rules of the ASME Code, S tio XI.
7 Signed Date M k/
19 W
@M By J.C.P.6L.
Owner Certificate of Authorization No. (if applicable)
N/A Expiration Date N/A CERTIFICATE OF INSERVICE INSPECTION i
s 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and/or the State or Province of New Jersey and employed by H. S. B. I. 61. Co.
of Unrtford Ct.
have inspected the compwents described in this Owners' Data Report during the period l')/16/34 to 10/22/96
. and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners' Data Report in accordance with the requirements of the ASME Code, Section AI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners' Data Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personalinjury or property damage or a loss of any kind arising from or connected with this inspection.
., /1tL_2 7 1997 Date
/
Commissions NB5478(I) (N) NJ442 In. ector's Signatur National Board, State, Province and No.
i r
i I
]
1 l
l
1 NIS-1 REPORT ABSTRACT 10.
This submittal is for ISI examinations performed during Oyster Creek's refueling outage 16R., These examinations completes the second period requirements for the " Third Inspection Interval." See the attached, " Ten Year Inspection Scope Statistical Report" for details.
The ISI scope initially scheduled nine category B-D examinations. Only seven were completed. Two Core Spray Nonle to Vessel Welds was determined inaccessible due to the bio-shield opening configuration. These welds have been re-scheduled for refueling outage 18R. During outsige 18R the Feed Water Nonles are scheduled for ISI examinations. At that time the bio-shield opening for the Feed Water Nonles would be open also providing a greater access to the Core Spray Nozzles Seven category B-F examinations were scheduled, and only five were completed. Two Isolation Condenser Nozzle to Safe-end welds were not performed because of material concerns with the calibration block. These welds were re-scheduled for examination durmg i
refueling outage 17R.
Sixteen IGSCC examinations were applied to ISI Section XI credit. Five for category B-F and eleven for category B-J. These sixteen examinations were perfonned utilizing PDI qualified procedures and technique. Although the examinations were performed by an
)
approved PDI technique, the examinations did not fully comply with Section XI Appendix 111 from the 1986 or 1992 Edition. Relief Request Ri1 Rev. I was applied for crediting j
these IGSCC exams toward Section XI. These exams are noted on the NIS-1 Report in the remarks colunm.
11.
Reactor Vessel: Six vessel internals components were reported to have indications. The Steam SEPARATOR, Lower Shroud Conical Support, Steam Dryer Lug, Shroud Vertical Weld, Top Guide, and the Feedwater Sparger Adjusting Nut / Bolt.
COMPONENT DEFICIENCY DISPOSITION STEAM SEPARATOR (1) mid support ring Use as is re-exam during stiffener cracked completely 17R from ring section at holt hole location #18 (2) one crack at bolt hole Use as is re-exam during Location #7 reported during 17R ISR, appears to have grown.
(3) one small linear Use as is re-exam during indication / crater at 0 deg.
17R on stiffener mid support ring weld (top).
i
LOWER SilROUD Base material top and side Use as is re-exam during CONICAL SUPPORT of conical support to shroud 17R weld has additional linear indications from reported in ISR STEAM DRYER LUG Damage to lug was done Use as is
@l35 deg. and 45 deg.
while removing steam separator during 16R SilROUD VERTICAL Weld V-9 has transverse Use as is. Future WELD and 4 small parallel cracks examination shall be conducted in accordance with VIP criteria TOP GUIDE Additional cracks detected Use as is using UT examinations at the intersections. No additional cracks that were located on the bottom surface of the top guide.
l ITEDWATER SPARGER Crack was reported in the Use as is ADJUSTING NUT /ROLT Tack weld.
j Piping: Seven components were noted as having minor deliciencies, five surface and two VT-3 exams See Table 2 for details.
12.
The corrective measures taken for the founded deficiencies are discussed in Table 2.
J s
TEN YEAR INIPECTION SCOPE CTATIOTICAL REPORT CATEGORY CYCLE
-___.-_-+--____--+------__+______-_+-_______+________.
FREQUENCYi PERIOD 1 IPERIOD 21 PERIOD 3 i
PERCENT I
1 1
I I
I I
I l
1 114R 815R 616R 117R 118R 1
TOTAL
__-___-__+_----___+--_-__--+-___-___+________+-_--_-__+
8-A I
O I 4 i O I O I 19 1 23 I
O.00 i O.26 i O.00 1 0.00 1 1
8 1.48
_________+________+-_______..
_____.+_.___-__+___-.22 i
B-D I
2 1 14 1 16 1 4 I 12 6 48 i
O.13 i O.90 1 1.03 i O.26 i O.77 4 3.08 s
4
________.+_-______+ ______.+-_______._--_-___,______-_+
B-E I
19 i O l O I 6 8 6 4 31 3
1 1.22 i O.00 i O.00 i O.39 i O.39 1 1.99 3
___-___-_+__.-____+________+_______.+_ --____+-_--____+
^
B-F i
3 1 20 t O I 9 1 11 1 43 I
O.19 8 1.29 I O.OO 1 0.58 i O.71 I 2.76
______-_-+___-____+--_-__-_+-__-____+_-___-__+___-____+
D-C-1 I
O I 6 1 5 I to i 16 1 37 s
J l
O.00 1 0.39 i O.32 i O.64 1 1.03 1 2.37 4
B-G-2 1
11 1 3 1 5 6 7 1 6 4 32 4
..s.
I O.71 I O.19 i O.32 i O.45 1 0.39 l 2.05 eg
>D-B_J l
58 1 121 1 110 1 97 1 141 1 527 1
3.72 1 7.77 I 7.06 I 6.23 1 9.05 1 33.83
_________+._______+_____.-_+________+---_____+________+
B-L-2 i
O I 2 I O I to i 10 1 22 j
i O.00 1 0.13 i O.00 l O.64 i O.64 1 1.41
_______--+_-_____-+________+______..,________+-_______+
B-N-1 1
O I O I O I 1 I O 1 1
l O.00 1 0.00 i O.00 1 0.06 i O.00 1 0.06
_ _ _... _ - _ _ _. _ _ _ _ _ _ _ _, - _ - - _ _ - _ + - _ _ _ _ _ _ _ + _ - - _ _ - _ _, _ - _ _ _ - _ _ +
i.
B-M-2 1
5 1 7 i O I O I 2 1 14 i
O.32 i O.45 i O.00 i O.00 I O.13 i O.90
____--_-_+__-_____+_-______+___ --_-+_-__.-__+______~_+
B-N-1 1
33 1 1 1 1 1 44 1 43 1 122 4
i i
2.12 i O.06 i O.06 1 2.82 1 2.76 1 7.83
_______--+________+___-____+--___---.--___-_-+__-___--+
B-N-2 1
15 1 5 1 21 1 22 1 22 1 85 t
0.96 i O.32 1 1.35 1 1.41 1
1.41 1
5.46
_________+_____--.._____ __+___---__+___-__--+__-_-___+
D-0 1
O I O t O
4 0 1 3 1 3
1 i
O.00 1 0.00 1 0.00 i O.no 1 0.19 i O.19 s
___._____.________+ _______+________.____...__+____.__.
B-P i
1 1 2 1 1 i 1 1 1 1 6
i O.06 i O.13 i O.06 1 0.06 i O.06 i O.39
_____.-__+_____-__+____--__+_ -----_,____-___.----_-_-+
C-A i
1 1 O I O I 2 1 3 1 6
l 1
0.06 i O.00 i O.00 t 0.13 i O.19 i O.39
---_-___-.___--___ ________.________+ ___----.--______.
C-B I
9 i O I 1 1 6 1 15 1 31 l
t 0.50 i O.00 i O.06 6 0.39 i O.96 4 1.99
-________+__-- ___._-____-_+________.______--.________+
C-C i
O I O I 2 1 21 1 18 1 41 4
i O.OO I O.00 i O.13 1 1.35 1 1.16 1 2.63 i
_________+._______+-___.___.________.________+_____-__+
- -D I
O t O I O '
2 '
O I 2
i O.00 1 0.00 #
0.00 i O.13 i O.00 i O.13 s
_________.________+ ____ __.________.________. _______+
4 C -F - 1 1
8 l
14 1 14 i 20 l 12 1 68 l
1 0.51 0.90 i O.90 1 1.28 i O.77 1 4.36 a
_________ ________...______+________.________+________+
j C-F-2 1
21 l 13 1 27 1 22 1 26 1 169 1
1.35 I O.83 1 1.73 1 1.41 1
I e
)
--_______+--______+________+___~____,________+____1.67 C-H I
O I 12 1 2 i O I O I 14 1
1 0.00 1 0.77 i O.13 s 0.00 i O
i O.90
-__._____+-__-____.________..._-____._..______+_____.00 i
D-B 3
11 1 12 1 9 i 14 8 14 4 60
___+
4 i
O.71 i
O.77 i O.58 0.90 i 1
3 H5
_________..---____+________+________.________+___O.00 3
D-C i
o f 5 4 1 1 3 8 2 1 11 1
0.00 1 0.32 i O.06 i O.19 i i
O.71
_________+________.._______. -______,__.._____+
__O.13
_____+
F-A I
28 1 32 1 56 6 60 1 46 1 222 i
1.80 1 2.05 1 3.59 t
3.85 1 2
1 14.25
_________.________+____ ___.________.________ _____.95 TOTst 225 273 271 361 428 1558 14.44 17.52 17.39 23.17 27.47 100.00
PAGE [ CF [
NIS-1 OWNERS DATA REPORT FOR INSERVICE INSPECTIONS JERSEY CENTRAL POWER AND LIGHT COMPANY 1.
OWNER: MADISON AVENUE AT PUNCHBOWL ROAD MORRISTOWN,N.J. 07960 1
3 OYSTER CREEK NUCLEAR GENERATING STATION 2.
PLANT: ON U.S.
RT.9, 2 MILES SOUTH OF FORKED RIVER.N.J. 08731 3.
UNIT: OYSTER CREEK NUCLEAR GENERATING STATION 4.
OWNER CERTIFICATE OF AUTHO TION (IF REQUIRED) NONE 5.
COMMERICAL SERVICE DATE 12 69 6.
NATIONAL BOARD NUMBER FOR RX VESSEL 14895
- e**********************************************************************************************
- SECTION XI COMPONENT TAG COMPONENT SYSTEM METHOD EXAM DATE REMARKS
- CATEGORY /ITEMNO EXAM NO.
DESCRIPTION CREDIT B-F B5.10 NR02/1-567A/ WELD N6A CORE SPRAY NOZZLE 221 SUR 17SEP1996 000001825 SAFE END ISI B-F B5.10 NR02/1-567A/ WELD N6A CORE SPRAY NOZZLE 221 UT 23SEP1996 RELIEF 000001826 SAFE END ISI R11 REV.1 B-F B5.10 NR02/1-567B/ WELD N6B CORE SPRAY NOZZLE 221 SUR 17SEP1996 000001830 SAFE END ISI B-F B5.10 NR02/1-567B/ WELD N6B CORE SPRAY NOZZLE 221 UT 22SEP1996 RELIEF 000001831 SAFE END ISI R11 REV.1 B-F B5.10 NR02/2-565C/ WELD N2C RECIRC INLET NOZZLE 221 SUR 13SEP1996 000001803 SAFE END ISI B-F B5.10 NR02/2-565C/ WELD N2C RECIRC INLET NOZZLE 221 UT 24SEP1996 RELIEF 000001804 SAFE END ISI R11 REV.1 B-F B5.10 NR02/2-565D/ WELD N2D RECIRC INLET NOZZLE 221 SUR 12SEP1996 000001807 SAFE END ISI B-F B5.10 NR02/2-565D/ WELD N2D RECIRC INLET NOZZLE 221 UT 17SEP1996 RELIEF 000001808 SAFE END ISI R11 REV.1 B-F B5.10 NR02/2-565E/ WELD N2E RECIRC INLET NOZZLE 221 UT 25SEP1996 RELIEF 000001812 SAFE END ISI R11 REV.1 B-F B5.10 NR02/2-565E/ WELD N2E RECIRC INLET NOZZLE 221 SUR 13SEP1996 000002990 SAFE END ISI B-F B5.10 NR02/2-565E/ WELD N2E RECIRC INLET NOZZLE 221 SUR 19SEP1996 000002990 SAFE END ISI B-J B9.11 NG-A-0001A// WELD SAFE END TO ELBOW 223 UT 20SEP1996 RELIEF 000000528 ISI R11 REV.1 B-J B9.11 NG-A-0001A// WELD SAFE END TO ELBOW 223 SUR 13SEP1996 000000529 ISI B-J B9.11 NG-A-0019// WELD VALVE TO PIPE 223 UT 17SEP1996 RELIEF 000000534 ISI R11 REV.1
~
e G
S
.~.
- OF p[
NIS-1 OWNERS DATA REPORT FOR INSERVICE INSPECTIONS PAGE #
JERSEY CENTRAL POWER AND LIGHT COMPANY h
1.
OWNER: MADISON AVENUE AT PUNCHBOWL ROAD MORRISTOWN,N.J. 07960 3
OYSTER CREEK NUCLEAR GENERATING STATION 2.
PLANT: ON U.S.
RT.9, 2 MILES SOUTH OF FORKED RIVER,N.J. 08731 3.
UNIT: OYSTER CREEK NUCLEAR GENERATING STATION 4
- 4. OWNER CERTIFICATE OF AUTHO I TION (IF REQUIRED) NONE 5.
COMMERICAL SERVICE DATE 12 23 69 6.
NATIONAL BOARD NUMBER FOR II RX VESSEL 14895
- SECTION XI COMPONENT TAG COMPONENT SYSTEM METHOD EXAM DATE REMARKS
- CATEGORY /ITEMNO EXAM NO.
DESCRIPTION CREDIT B-J B9.11 NG-A-0019// WELD VALVE TO PIPE 223 SUR 11SEP1996 000000535 ISI B-J B9.11 NG-B-0017// WELD VALVE TO PIPE 223 UT 15SEP1996 RELIEF 000000542 ISI R11 REV.1 B-J B9.11 NG-B-0017// WELD VALVE TO PIPE 223 SUR 11SEP1996 000000543 ISI B-J 89.11 NG-C-0023A// WELD PIPE TO SAFE END 223 SUR 14SEP1996 000001805 ISI B-J B9.11 NG-C-0023A// WELD PIPE TO SAFE END 223 UT 24SEP1996 RELIEF 000001806 ISI R11 REV.1 B-J B9.11 NG-D-0002// WELD ELBOW TO PIPE 223 UT 19SEP1996 RELIEF 000000555 ISI R11 REV.1 B-J B9.11 NG-D-0002// WELD ELBOW TO PIPE 223 SUR 14SEP1996 000000556 ISI B-J B9.11 NZ-3-0044A// WELD REDUCER TO SAFE END 212 UT 21SEP1996 RELIEF 000000329 ISI R11 REV.1 B-J B9.11 NZ-3-0044A// WELD REDUCER TO SAFE END 212 SUR 17SEP1996 000000332 ISI B-J B9.11 NZ-3-0044B// WELD SAFE END TO SAFE END 212 UT 21SEP1996 RELIEF 000000333 ISI R11 REV.1 B-J B9.11 NZ-3-0044B// WELD SAFE END TO SAFE END 212 SUR 17SEP1996 000000336 ISI B-J B9.11 NZ-3-0096// WELD REDUCER TO SAFE END 212 UT 21SEP1996 RELIEF 000000377 ISI R11 REV.1 B-J B9.11 NZ-3-0096// WELD REDUCER TO SAFE END 212 SUR 17SEP1996 000000378 ISI B-J B9.11 NZ-3-0096A// WELD SAFE END TO SAFE END 212 UT 21SEP1996 RELIEF 000000379 ISI R11 REV.1 4
o 4
h
-_-._-_-..-_______..-__--____-.---________,_---_.----__--,_---_-__.__---.---------____-----,__.--_-___-e w
~
NIS-1 OWNERS DATA REPORT FOR INSERVICE INSPECTIONS PAGE,/ OF[
JERSEY CENTRAL POWER AND LIGHT COMPANY 1.
OWNER: MADISON AVENUE AT PUNCHBOWL ROAD MORRISTOWN,N.J. 07960 3
'3 OYSTER CREEK NUCLEAR GENERATING $1TATION 2.
PLANT: ON U.S.
RT.9, 2 MILES SOUTH OF FORKED RIVER,N.J. 08731
- 3. UNIT: OYSTER CREEK NUCLEAR GENERATING STATION
- 4. OWNER CERTIFICATE OF AUTHO I TION (IF REQUIRED) NONE 5.
COMMERICAL SERVICE DATE 12 23 69
- 6. NATIONAL BOARD NUMBER FOR NI RX VESSEL 14895
- SECTION TI COMPONENT TAG COMPONENT SYSTEM METHOD EXAM DATE REMARKS
- CATEGORY /ITEMNO EXAM NO.
DESCRIPTION CREDIT B-J B9.11 NZ-3-0096A// WELD SAFE END TO SAFE END 212 SUR 17SEP1996 000000380 ISI B-J B9.12 NG-A-0019A// WELD LONGITUDINAL WELD ON PIPE 223 SUR 13SEP1996 000004184 ISI B-J B9.12 NG-A-0019A// WELD LONGITUDINAL WELD ON PIPE 223 UT 12SEP1996 RELIEF 000004217 ISI R11 REV.1 B-J B9.12 NG-B-0017A// WELD LONGITUDINAL WELD ON PIPE 223 UT 15SEP1996 RELIEF 000003211 ISI R11 REV.1 B-J B9.12 NG-B-0017A// WELD LONGITUDINAL WELD ON PIPE 223 SUR 11SEP1996 000003212 ISI e
4
NIS-1 OWNERS DATA REPORT FOR IWSERVICE INSPECTIOM DATE: 01/13/97 i
PAGE: 0001 i
- 1. OWMER: Jersey Central Power & Light Company, Madison Avenue &
Punch Bowl Road, Morristown,,New Jergey 2.
PLAMT: Oyster Creek Muclear Generating Station, U.S.
Route 9, Forked River, New Jersey 3.
PLANT UNIT: NA 4.
OWNER CERTIFICATION OF AUTH ZATION (if required) : None 5.
COMMERCIAL SERVICE DATE: 1
/69
- 6. NATIONAL BOARD NUMBER FOR
- Reactor Vessel 14895 3
OUTAGE 16R TABLE 1 i
1 i
IDENTIFICATION EXAM i
ASME ASME TAG NUMBER NDE DATE/
FROM DIAM./
4 CAT ITEM NO SUFFIX CODE DESCRIPTION SYST METH REASON TO DIAM.
REMARKS i
1-565A WELD A-LOOP ISI B-D B3.100-NR02 N2B RECIRC INLET NOZZLE RX UT 092496 26.000 1-565B WELD B-LOOP ISI a
B-D B3.100 NR02 N2C RECIRC INLET NOZZLE RX UT 092196 26.000 1
B-D B3.107 NR02 N2D RECIRC INLET NOZZLE RX UT 092396 26.000
' 1-565D WELD D-LOOP ISI B-D B3.100 NR02 N2E RECIRC INLET NOZZLE RX UT 092196 26.000 1
B-D B3.100 NR02 NSA ISOLATION COND NOZZLE RX UT 092196 228.000 i-566A WELD ISI 10.000 B-D B3.100 NRC2 NSB ISOLATION COND NOZZLE RX UT 091496 228.000 2 - S t. 6 B WELD ISI 10.000 B-D B3.100 NR02 N6B CORE SPRAY NOZZLE RX UT 092496 6.000 2-567B WELD ISI 228.000 B-D B3.90 NR02 N2A RECIRC INLET NOZZLE RX UT 091996 26.000 1-565A miELD A-LOOP ISI B-D B3.90 NR02 N2B RECIRC INLET NOZZLE RX UT 092496 26.000 1-565B WELD B-LOOP ISI l'
B-D B3.90 NR02 N2C RECIRC INLET NOZZLE RX UT 092196 26.000 1-565C WELD C-LOOP ISI B-D B3.90 NR02 N2D RECIRC INLET NOZZLE RX UT 092396 26.000 1-565D WELD D-LOOP ISI B-D B3.90 NR02 N2E RECIRC INLET NOZZLE RX UT 092196 26.000 1-565E WELD E-LOOP ISI B-D B3.90 NR02 NSA ISOLATION COND NOZZLE RX UT 092196 228.000 2-566A WELD ISI 10.000 i
B-D B3.90 NR02 NSB ISOLATION COND NOZZLE RX UT 092196 228.000 2-566B WELD ISI 10.000 B-D B3.90 NR02 N6B CORE SPRAY NOZZLE RX UT 092396 6.000 2-567B WELD ISI 228.000
]
B-G-1 B6.10 NR02 CLOSURE NUT (64)
RX SUR 091396 9.375 INSPECT NUTS 22-43 573-02 BOLT ISI B-G-1 B6.20 NR02 CLOSURE STUD (64)
RX UT 090896 6.000 INSPECT STUDS 23-44 573-01 BOLT ISI 6.000 B-G-1 B6.40 NR02 THREADS IN RX VESSEL FLAN RX UT 090896 229.000 INSPECT THREADS IN FLANG 23-44 563-02 BOLT GE ISI i
B-G-1 B6.50 NR02 CLOSURE WASHER BOTTOM (64 RX VT-1 091396 INSPECT 22-43 573-07 BOLT
)
ISI B-G-1 B6.50 NR02 CLOSURE WASHER UPPER (64)
RX VT-1 091396 INSPECT 22-43 573-08 BOLT ISI B-G-2 B7.50 216-BG-001 BOLTING ON 6" FLANGE RX RHC VT-1 092196
.875 BOLT SIDE REMOVABLE PEICE ISI i
i Y
4
B3IS-1 OWNERS DATA REPORT FOR INSERVICE INSPECTIOM DATE: 01/13/97 PAGE: 0002
- 1. OWNER: Jersey Central Power & Light Company, Madison Avenue &
Punch Bowl Road, Morristown, New Jergiey 2.
PLANT: Oyster Creek Nuclear Generating Station, U.S.
Route 9, Forked River, New Jersey 3.
PLANT UNIT: NA
- 4. OWNER CERTIFICATION OF AUTH RIZATION (if required): None
- 5. COMMERCIAL SERVICE DATE: 1 23/69
- 6. NATIONAL BOARD NUMBER FOR IT: Reactor Vessel 14895 OUTAGE 16R TABLE 1 IDENTIFICATION EXAM ASME ASME TAG NUMBER NDE
'DATE/
PROM DIAM./
CAT ITEM NO SUFFIX CODE DESCRIPTION SYST METH REASON TO DIAM.
REMARKS B-C-2 B7.70 V-1-0160 BONNET BOLTING MS VT-1 092096 REMOVED REPLACED WITH SPARE RX SAF BOLT PSI ETY VALDE. NEW BOLTS WERE INSTALLED B-G-2 B7.70 V-1-0163 BONNET BOLTING MS VT-1 092096 REMOVED REPLACED WITH SPARE RX SAF BOLT PSI ETY VALYE. NEW BOLTS WERE INSTALLED B-G-2 B7.70 V-14-0032 V-14-32 BONNET BOLTING NE VT-1 121295 10.000 BOLT ISI B-G-2 B7.70 NG-E-BG001 REACTOR RECIRCULATION NG VT-1 092296 2.000 BOLT DECON CONNECTION PSI B-G-2 B7.70 V-17-0207 BONNET BOLTING NU VT-1 121295 8.000 BOLT ISI l
B-G-2 B7.70 V-1-0173 BONNET BOLTING NZ VT-1 092096 REMOVED REPLACED WITH SPARE EMRV N 1
BOLT PSI EW BOLT 5 WERE INSTALLED B-G-2 B7.70 V-1-0174 BONNET BOLTING NZ VT-1 092096 REMOVED REPLACED WITH SPARE EMRV.
BOLT PSI NEW BOLIS WERE INSTALLED l
B-G-2 B7.70 V-1-0175 BONNET BOLTING NZ VT-1 091196 BOLT ISI B-G-2 B7.70 V-1-0177 BONNET BOLTING NZ VT-1 092096 REMOVED REPLACED WITH SPARE EMRV.
BOLT PSI NEW BOLIS WERE INSTALLED.
B-G-2 B7.70 V-20-0151 BONNET BOLTING NZ VT-1 091396 8.000 BOLT ISI B-J B9.11 MS-1-0033 ELBOW TO PIPE MS UT 091196 24.000 WELD ISI B-J B9.11 MS-1-0033 ELBOW TO PIPE MS SUR 091196 24.000 WELD ISI B-J B9.11 ND-10-0007 ELBOW TO PIPE ND UT 091796 6.000 WELD ISI B-J B9.11 ND-10-0007 ELBOW TO PIPE ND SUR 091796 6.000 WELD ISI B-J B9.11 ND-1-0001 NOZZLE TO PIPE ND UT 092096 6.000 WELD ISI B-J B9.11 ND-1-0001 NOZZLE TO PIPE ND SUR 091796 6.000 WELD ISI B-J B9.11 ND-1-0007 VALVE TO PIPE ND UT 091896 6.000 WELD ISI B-J B9.11 ND-1-0007 VALVE TO PIPE ND SUR 091796 6.000 WELD ISI B-J B9.11 ND-10-0200 ELBOW TO PIPE ND UT 091796 6.000 WELD ISI B-J B9.11 ND-10-0200 ELBOW TO PIPE ND SUR 091796 6.000 WELD ISI B-J B9.11 ND-1-0021 ELBOW TO PIPE ND UT 091896 6.000 WELD ISI B-J B9.11 ND-1-0021 ELBOW TO PIPE ND SUR 091796 6.000 WELD ISI W
O i
f
NIS-1 OWNERS DATA REPORT FOR INSERVICE INSPECTION DATE: 01/13/97 PAGE: 0003 1.
OWNER: Jersey Central Power 6 Light Company, Madison Avenue &
Punch Bowl Road, Morristown,,New Jergey 2.
PLAMT: Oyster Creek Nuclear Generating Station, U.S.
Route 9, Forked River, New Jersey 3.
PLANT UNIT: NA
- 4. OWNER CERTIFICATION OF AUTHORIZATION (if required): None
- 5. COMMERCIAL SERVICE DATE: 12/23/69
- 6. NATIONAL BOARD NUMBER FOR UNIT: Reactor Vessel 14895 OUTAGE 16R TABLE 1 IDENTIFICATION EXAM ASME ASME TAG NUMBER NDE DATE/
FROM DIAM./
CAT ITEM NO SUFFIX CODE DESCRIPTION SYST METH REASON TO DIAM.
REMARKS 52 ~7-~~5h'((~~hk252hhhh ~ ~"~~~~~~~~5kyk~hhb'Tb ULbbW hb bbk b95b96 5b$bbb WELD ISI 10.000 B-J B9.11 NE-5-0002 SAFE END TO ELBOW NE UT 091496 10 000 WELD ISI 10.000 B-J B9.11 NE-5-0022A SAFE END TO ELBOW NE SUR 091296 10.000 WELD ISI B-J B9.11 NE-5-0022A SAFE END TO ELBOW NE UT 091396 10.000 WELD ISI B-J B9.11 NU-1-0002 PIPE TO PIPE NU UT 091196 14.000 4
WELD ISI B-J B9.11 NU-1-0002 PIPE TO PIPE NU SUR 091196 14.000 WELD ISI 3
B-J B9.11 NU-1-0008 PIPE TO ELBOW NU UT 091196 14.000 WELD ISI i
B-J B9.11 NU-1-0008 PIPE TO ELBOW NU SUR 091196 14.000 WELD ISI B-J B9.11 NU-1-0032 ELBOW TO VALVE NU UT 082196 10.000 WELD ISI B-J B9.11 NU-1-0032 ELBOW TO VALVE NU SUR 082196 10.000 WELD ISI B-J B9.11 NU-1-0036 PIPE TO REDUCER TEE NU UT 082296 14.000 i
l WELD ISI B-J B9.11 NU-1-0036 PIPE TO REDUCER TEE NU SUR 082196
- 14. 000 WELD ISI B-J B9.11 NU-4-0002 TEE TO VALVE NU UT 10.000 WELD ISI B-J B9.11 NU-4-0002 TEE TO VALVE NU SUR 091596 10.000 WELD ISI B-J B9.11 NZ-3-0012 PIPE TO ELBOW NZ UT 082096 8.000 WELD ISI 4
B-J B9.11 NZ-3-0012 PIPE TO ELBOW NZ SUR 082096 8.000 WELD ISI B-J B9.11 NZ-3-0034 ELBOW TO ELBOW NZ UT 091296 r 100 WELD ISI t
B-J B9.11 NZ-3-0034 ELBOW TO ELBOW NZ SUR 091296 8.000 WELD ISI B-J B9.11 NZ-3-0060 PIPE TO TEE NZ UT 082396 8.000 WELD ISI B-J B9.11 NZ-3-0060 PIPE TO TEE NZ SUR 082396 8.000 WELD ISI B-J B9.11 NZ-3-0074 ELBOW TO PIPE NZ UT 091496 8.000 WELD ISI B-J B9.11 NZ-3-0074 ELBOW TO PIPE NZ SUR 091396 8.000 WELD ISI d
4 e
_v
=.%
--vw
-s y
.-,yw y
>-..,._m.,cy,,ip..
..--..,,m.*
t-
-w-
'*-W
+ +-
- -w rv-t m. w n *
- -*w
- -v
- T
'T
NIS-1 OWNERS DATA REPORT FOR INSERVICE INSPECTION DATE: 01/13/97 PAGE: 0004
- 1. OWNER: Jersey Central Power 6 Light Company, Madison Avenue &
Punch Bowl Road, Morristown New Jergey
- 2. PLANT: Oyster Creek Nuclear Generaf.ing Station, U.S.
Route 9,
Forked River, New Jersey 3.
PLANT UNIT: NA
- 4. OWNER CERTIFICATION OF AUTHORI TION (if required): None
- 5. COMMERCIAL SERVICE DATE: 12/23 69
- 6. NATIONAL BOARD NUMBER FOR UNIT Reactor Vessel 14895 OUTAGE 16R TABLE 1 IDENTIFICATION EXAM ASME ASME TAG NUMBER NDE DATE/
FROM DIAM./
CAT ITEM NO SUFFIX CODE DESCRIPTION SYST METH REASON TO DIAM.
REMARKS B-J B9.11 RF-2-0025 PIPE TO ELBOW RF UT 091796 18.000 WELD ISI B-J B9.11 RF-2-0025 PIPE TO ELBOW RF SUR 091796 18.000 WELD ISI B-J B9.11 RF-2-0040 ELBOW TO PIPE RF UT 091296 10.000 WELD ISI B-J B9.11 RF-2-0040 ELBOW TO PIPE RF SUR 091196 10.000 WELD ISI B-J B9.11 RF-2-0041 PIPE TO ELBOW RF UT 091196 10.000 WELD ISI B-J B9.11 RF-2-0041 PIPE TO ELBOW RF SUR 091196 10.000 WELD ISI B-J B9.11 RHC-2-0041 REDUCER TO ELBOW RHC UT 090996 6.000 WELD ISI B-J B9.11 RHC-2-0041 REDUCER TO ELBOW RHC SUR 090796 6.000 WELD ISI B-J B9.12 MS-1-0032A LONGITUDINAL WELD ON EXTR MS UT 091196 24.000 WELD ADOS OF ELBOW ISI B-J B9.12 MS-1-0032A LONGITUDINAL WELD ON EXTR MS SUR 091196 24.000 WELD ADOS OF ELBOW ISI B-J B9.12 MS-1-0032B LONGITUDINAL WELD ON INTR MS UT 091196 26.000 WELD ADOS OF ELBOW ISI B-J B9.12 MS-1-0032B LONGITUDINAL WELD ON INTR MS SUR 091196 26.000 WELD ADOS OF ELBOW ISI B-J B9.12 ND-10-0007B LONGITUDINNAL WELD ON EXT ND SUR 091796 6.000 WELD RADOS OF ELBOW ISI B-J B9.12 ND-10-0007B LONGITUDINNAL WELD ON EXT ND UT 091796 6.000 WELD RADOS OF ELBOW ISI B-J B9.12 ND-10-0007C LONGITUDINNAL WELD ON INT ND UT 091796 6.000 WELD RADOS OF ELBOW ISI B-J B9.12 ND-10-0007C LONGITUDINNAL WELD ON INT ND SUR 091796 6.000 WELD RADOS OF ELBOW ISI B-J B9.12 ND-1-0020A LONGITUDINNAL WELD ON EXT ND UT 091896 6.000 WELD RADOS OF ELBOW ISI B-J B9.12 ND-1-0020A LONGITUDINNAL WELD ON EXT ND SUR 091796 6.000 WELD RADOS OF ELBOW ISI B-J B9.12 ND-1-0020B LONGITUDINNAL WELD ON INT ND UT 091896 6.000 WELD RADOS OF ELBOW ISI B-J B9.12 ND-1-0020B LONGITUDINNAL WELD ON INT ND SUR 091796 6.000 WELD RADOS OF ELBOW ISI B-J B9.12 NE-5-0002A LONGITUDINAL WELD ON EXTR NE UT 091596 10.000 WELD ADOS OF ELBOW ISI B-J 89.12 NE-5-0002A LONGITUDINAL WELD ON EXTR NE SUR 091296 10.000 WELD ADOS OF ELBOW ISI Y
e 4
NIS-1 OWNERS DATA REPORT FOR INSERVICE INSPECTION DATE: 01/13/97 PAGE: 0005
- 1. OWNER: Jersey Central Power & Light Company, Madison Avenue &
Punch Bowl Road, Morristown, New Jergey 2.
PLANT: Oyster Creek Nuclear G nerating Station, 9
U.S.
Route 9, Forked River, New Jersey 3.
PLANT UNIT: NA
- 4. OWNER CERTIFICATION OF AUTH RI ION (if required): None 5.
COMMERCIAL SERVICE DATE: 12 23 69
- 6. NATIONAL BOARD NUMBER FOR IT Reactor Vessel 14895 OUTAGE 16R TABLE 1 IDENTIFICATION EXAM ASME ASME TAG NUMBER NDE DATE/
FROM DIAM./
CAT ITEM NO SUFFIX CODE DESCRIPTION SYST METH REASON TO DIAM.
REMARKS bb b9$55 b5 Sbbbbb
~bbhbiTbbihEL'EbLb b 'khhR hb bh b95b96 Eb$bbb 5
WELD ADOS OF ELBOW 1SI B-J B9.12 NE-5-0002B LONGITUDINAL WELD ON INTR NE SUR 091296 10.000 t
WELD ADOS OF ELBOW ISI B-J B9.12 NE-5-0022B LONGITUDINAL WELD ON INTR NE UT 091296 10.000 WELD ADOS OF ELBOW ISI B-J B9.12 NE-5-0022B LONGITUDINAL WELD ON INTR NE SUR 091296 10.000 WELD ADOS OF ELBOW ISI B-J B9.12 NE-5-0022C LONGITUDINAL WELD ON EXTR NE UT 091296 10.000 WELD ADOS OF ELBOW ISI B-J B9.12 NE-5-0022C LONGITUDINAL WELD ON EXTR NE SUR 091296 10.000 i
WELD ADOS OF ELBOW ISI B-J B9.12 NG-A-0001B LONGITUDINAL WELD ON EXTR NG UT 091396 26.000 1
B-J B9.12 NG-A-0001B LONGITUDINAL WELD ON EXTR NG SUR 091396 26.000 WELD ADOS OF ELBOW ISI B-J B9.12 NG-A-0001C LONGITUDINAL WELD ON INTR NG UT 091396 26.000 WELD ADOS OF ELBOW ISI B-J B9.12 NG-A-0001C LONGITUDINAL WELD ON INTR NG SUR 091396 26.000 WELD ADOS OF ELBOW ISI B-J B9.12 NG-C-0023B LONGITUDINAL WELD ON PIPE NG UT 091496 26.000 WELD ISI B-J B9.12 NG-C-0023B LONGITUDINAL WELD ON PIPE NG SUR 091496 26.000 WELD ISI B-J B9.12 NG-D-0001B LONGITUDINAL WELD ON EXTR NG UT 091696 26.000 i
B-J B9.12 NG-D-0001B LONGITUDINAL WELD ON EXTR NG SUR 091696 26.000 WELD ADOS OF ELBOW ISI j
B-J B9.12 NG-D-0001C LONGITUDINAL WELD ON INTR NG UT 091696 26.000 WELD ADOS OF ELBOW ISI B-J B9.12 NG-D-0001C LONGITUDINAL WELD ON INTR NG SUR 091696 26.000 WELD ADOS OF ELBOW ISI B-J B9.12 NG-D-0002B LONGITUDINAL WELD ON PIPE NG UT 26.000 4
WELD ISI B-J B9.12 NG-D-0002B LONGITUDINAL WELD ON PIPE NG SUR 091696 26.000 WELD ISI I
B-J B9.12 NZ-3-0010A LONGITUDINAL WELD ON PIPE NZ SUR 082096 8.000 WELD ISI B-J B9.12 NZ-3-0010A LONGITUDINAL WELD ON PIPE NZ UT 082096 8.000 WELD ISI B-J B9.12 NZ-3-0012A LONGITUDINAL WELD ON INTR NZ UT 082096 8.000 WELD ADOS OF ELBOW ISI B-J B9.12 NZ-3-0012A LONGITUDINAL WELD ON INTR NZ SUR 082096 8.000 WELD ADOS OF ELBOW ISI 9
e 1
4
- - - - - _ _ - _ - - - _ - _ - -, --, - - =.
<r
+
+ -, ~ -
r
2 NIS-1 OWNERS DATA REPORT FOR INSERVICE INSPECTION DATE: 01/13/97 PAGE: 0006
- 1. OWNER: Jersey Central Power & Light Company, Madison Avenue &
i Punch Bowl Road, Morristown.New Jersey
- 2. PLANT: Oyster Creek Nuclear Generabing Station, U.S.
Route 9,
Forked River, New Jersey 3.
PLANT UNIT: NA 4.
OWNER CERTIFICATION OF AUTH RIZATION (if required) - None
- 5. COMMERCIAL SERVICE DATE: 1 23/69
- 6. NATIONAL BOARD NUMBER FOR IT: Reactor Vessel 14895 OUTAGE 16R TABLE 1 i
IDENTIFICATION EXAM j
ASME ASME TAG NUMBER NDE DATE/
FROM DIAM./
CAT ITEM NO SUFFIX CODE DESCRIPTION SYST METH REASON TO DIAM.
REMARKS bU bb$52 bb 5 bb5bb bbhbkTbbkbkb kbLb bh bETk hb bT bbbbb6 b$bbb WELD ADOS OF ELBOW ISI i
B-J 39.12 NZ-3-0012B LONGITUDINAL WELD ON EXTR NZ SUR 082096 8.000 t
B-J B9.12 NZ-3-0033A LONGITUDINAL WELD ON EXTR NZ UT 091296 8.000 WELD ADOS OF ELBOW ISI B-J B9.12 NZ-3-0033A LONGITUDINAL WELD ON EXTR NZ SUR 091296 8.000 WELD ADOS OF ELBOW ISI i~
B-J B9.12 NZ-3-0033B LONGITUDINAL WELD ON INTR NZ UT 091296 8.000 WELD ADOS OF ELBOW ISI 3
B-J B9.12 NZ-3-0033B LONGITUDINAL WELD ON INTR NZ SUR 091296 8.000 4
WELD ADOS OF ELBOW ISI B-J B9.12 NZ-3-0034A LONGITUDINAL WELD ON EXTR NZ UT 091296 8.000 WELD ADOS OF ELBOW ISI B-J B9.12 NZ-3-0034A LONGITUDINAL WELD ON EXTR NZ SUR 091296 8.000 l
(
B-J B9.12 NZ-3-0034B LONGITUDINAL WELD ON INTR NZ UT 091296 8.000 WELD ADOS OF ELBOW ISI B-J B9.12 NZ-3-0034B LONGITUDINAL WELD ON INTR NZ SUR 091296 8.000 WELD ADOS OF ELBOW ISI B-J B9.12 NZ-3-0058 LONGITUDINAL WELD ON PIPE NZ UT 082396 8.000 j
WELD ISI B-J B9.12 NZ-3-0058 LONGITUDINAL WELD ON PIPE NZ SUR 082396 8.000 WELD ISI B-J B9.12 NZ-3-0073A LONGITUDINAL WELD ON THE NZ UT 091496 8.000 1
^
B-J B9.12 NZ-3-0073A LONGITUDINAL WELD ON THE NZ SUR 091396 8.000 WELD EXTRADOS OF ELBOW ISI 4
B-J B9.12 NZ-3-0073B LONGITUDINAL WELD ON INTR NZ UT 091496 8.000 WELD ADOS OF ELBOW ISI B-J B9.12 NZ-3-0073B LONGITUDINAL WELD ON INTR NZ SUR 091396 8.000 WELD ADOS OF ELBOW ISI B-J B9.12 NZ-3-0093A LONGITUDINAL WELD ON PIPE NZ UT 092096 WELD ISI B-J B9.12 NZ-3-0093A LONGITUDINAL WELD ON PIPE NZ SUR 091796 WELD ISI i
B-J B9.21 NC-2-0003 VALVE TO PIPE NC SUR 091896 3.000 WELD ISI B-J B9.32 NG-A-0009 ELBOW TO BRANCH NG SUR 091396 2.000 TEN SURFACE INDICATIONS WERE DETECT B-J B9.40 MS-9-0015 ELBOW TO PIPE MS SUR 196 2.000 WELD ISI B-J B9.40 MS-9-0015B COUPLING TO PIPE SOCKT MS SUR 091196 2.000 WELD ISI i
i 9
i 1
l
16IS-1 OWNERS DATA REPORT FOR INSERVICE INSPECTION DATE: 01/13/97 i
PAGE: 0007 1
- 1. OWNER: Jersey Central Power 6 Light Company, Madison Avenue &
Punch Bowl Road, Morristown, New Jergey 2.
PLAI+3T : Oyster Creek Nuclear Generating Station, U.S.
Route 9, Forked River. New Jersey 3.
PLANT UNIT: NA
- 4. OWNER CERTIFICATION OF AUTH TION (if required): None 5.
COMMERCIAL SERVICE DATE: 1 69
- 6. NATIONAL BOARD NUMBER FOR Reactor Vessel 14895 OUTAGE 16R TABLE 1 1
IDENTIFICATION EXAM ASME ASME TAG NUMBER NDE DATE/
FROM DIAM./
]
CAT ITEM NO SUFFIX CODE DESCRIPTION SYST METH REASON TO DIAM.
REMARKS l
b 7 bhI4b kb2h'bb57' '
h dhb'hb'P Pb bbbKh kb bbR bh5kh6 bbbb WELD ISI B-J B9.40 MV-5-0007 ELBOW TO PIPE SOCKT MV SUR 091896 2.000 WELD ISI B-J B9.40 MV-5-0021 TEE TO PIPE SOCKT MV SUR 091996 WELD ISI i
?
B-J B9.40 MV-5-0024 PIPE TO VALVE SOCKT MV SUR 091896 WELD ISI a
B-J B9.40 ND-1-0100 REDUCER TO REDUCER SOCKT ND SUR 091796 1.500 WELD ISI B-J B9.40 NG-B-0036A PIPE TO PIPE NG SUR 091296 2.000 WELD ISI 1
B-J B9.40 NG-C-0036 PIPE TO PIPE NG SUR 091096 2.000 4
WELD ISI B-J B9.40 NG-D-0024 PIPE TO ELBOW NG SUR 091396 2.000 WELD ISI B-J B9.40 NG-E-0032 TEE TO PIPE SOCKT NG SUR 091696 2,000 WELD ISI B-J B9.40 NP-2-0010 PIPE TO REDUCER TEE SOCKT NP SUR 091496 1.500 WELD ISI 2
B-N-1 B13.10 NR02 RX VESSEL INTERIOR SURFAC RX VT-3 091196 INTERNAL VESSEL ES ISI B-N-2 B13.20 NR02 SURV SPECIMEN HOLDER BRAC RX VT-1 091196 1
B-M-2 B13.20 NR02 SURV SPECIMEN HOLDER BRAC RX VT-1 091196 i
B-N-2 B13.20 NR02 SURV SPECIMEN HOLDER BRAC RX VT-1 091196 5-587C WELD KET UPPER ISI B-N-2 B13.20 NR02 SURV SPECIMEN HOLDER BRAC RX VT-1 091196 6-587A WELD KET LOWER ISI i
'(
B-N-2 B13.20 NR02 SURV SPECIMEN HOLDER BRAC RX VT-1 091196 6-587B WELD KET LOWER ISI B-N-2 B13.20 NR02 SURV SPECIMEN HOLDER BRAC RX VT-1 091196 6-587C WELD KET LOWER ISI B-N-2 B13.30 NR02 STEAM DRYER LUG RX VT-3 091196 l
B-N-2 B13.30 NR02 STEAM DRYER LUG RX VT-3 091196 1-587B WELD ISI B-N-2 B13.30 NR02 STEAM DRYER LUG RX VT-3 091196 1-587C WELD ISI B-N-2 B13.30 NR02 STEAM DRYER LUG RX VT-3 091196 1-587D WELD ISI i
B-N-2 B13.30 NR02 TRACK GUIDE BRACKET RX VT-3 091196 3-587A WELD ISI t
i l
t i
4 4
MIS-1 OWNERS DATA REPORT FOR INSERVICE INSPECTION DATE: 01/13/97 PAGE: 0008 1 OWWER: Jersey Central Power & Light Company, Madison Avenue &
1 Punch Bowl. Road, Morristown New Jergey
- 2. PLANT: Oyster Creek Nuclear G9nerabing Station, U.S.
Route 9, Forked River, New Jersey 3.
PLANT UNIT: NA 4.
OWNER CERTIFICATION OF AUTH ZATION (if required): None 5.
COMMERCIAL SERVICE DATE: 1
/69
- 6. NATIONAL BOARD NUMBER FOR
FROM DIAM./
i l
CAT ITEM NO SUFFIX CODE DESCRIPTION SYST METH REASON TO DIAM.
REMARKS B-E-2 B13.30 NR02 TRACK GUIDE BRACKET RX VT-3 091196 3-587B WELD ISI B-N-2 B13.30 NR02 FEEDWATER SPARGER BRACKET RX VT-3 091196 4-587A WELD ISI B-N-2 B13.30 NR02 FEEDWATER SPARGER BRACKET RX VT-3 091196 4-587B WELD ISI B-N-2 B13.30 NR02 FEEDWATER SPARGER BRACKET RX VT-3 061196 4-587C WELD ISI 4
B-N-2 B13.30 NR02 FEEDWATER SPARGER BRACKET RX VT-3 091196 1
4-587D WELD ISI B-N-2 B13.30 NR02 FEEDWATER SPARGER BRACKET RX VT-3 091196 4-587E WELD ISI B-E-2 B13.30 NR02 FEEDWATER SPARGER BRACKET RX VT-3 091196 4-587F WELD ISI B-M-2 B13.30 NR02 FEEDWATER SPARGER BRACKET RX VT-3 091196 4-587G WELD ISI i
l B-M-2 B13.30 NR02 FEEDWATER SPARGER BRACKET RX VT-3 091196 4-587H WELD ISI a
B-N-2 B13.40 NR02 CORE SUPPORT ASSEMBLY CON RX VT-3 091196 4-564 WELD ICAL SUPPORT TO VESSEL H-ISI B-P B15.10 NR02 REACTOR VESSEL RX VT-2 100696 VESSEL ISI C-B C2.31 H-21-001D CONTAINMENT SPRAY HEAT NQ SUR 090396 N-4-D WELD EXCHANGER 1-4 SHELL SIDE ISI C-C C3.20 241-BR-NQ-2-H26B-0031 ABANDON IN PLACE FRAME NQ SUR 091696 SUPORT (NO-2-H26B)
ISI C-C C3.20 NQZ-1-0060 SADDLE TO HEADER NQZ SUR 081696 RC ORD THE THICKNESS OF THE INTEGRA WELD ISI L1" VELDED ATTACHMENT IF THE THIC C-F-1 C5.11 NE-1-204 PIPE TO WYE NE SUR 090796 16.000 4
WELD ISI C-F-1 C5.11 NE-1-204 PIPE TO WYE NE UT 090996 16.000 FELD ISI C-F-1 C5.11 NE-1-229 PIPE TO NOZZLE B CONDENSR NE UT 091896 12.000 SOUTH END OF COND. B WELD ISI C-F-1 C5.11 NE-1-229 PIPE TO NOZZLE B CONDENSR NE SUR 091896 12.000 SOUTH END OF COND. B WELD ISI C-F-1 C5.11 NE-2-213 PIPE TO PIPE NE SUR 090996 8.000 WELD ISI C-F-1 C5.11 NE-2-213 PIPE TO PIPE NE UT 090996 8.000 l
WELD ISI C-F-1 C5.11 NE-2-214 PIPE TO PIPE NE SUR 090996 8.000 i
WELD ISI C-F-1 C5.11 NE-2-214 PIPE TO PIPE NE UT 090996 8.000 WELD ISI l
l 8
e
-,y
,-,y_..,
i NIS-1 OWNERS DATA REPORT FOR INSERVICE INSPECTION DATE: 01/13/97 t
PAGE: 0009
- 1. OWNER: Jersey Central Power & Light Company, Madison Avenue &
Punch Bowl Road, Morristown,,New Jersey 2.
PLANT: Oyster Creek Nuclear G nerating Station, 9
U.S.
Route 9,
Forked River, New Jersey 3.
PLANT UNIT: NA
- 4. OWNER CERTIFICATION OF AUTH RIZATION (if required): None
- 5. COMMERCIAL SERVICE DATE: 1 23/69 i
j
- 6. NATIONAL BOARD NUMBER FOR IT: Reactor Vessel 14895 OUTAGE 16R 1
TABLE 1 i
IDENTIFICATION EXAM REASO.[i FROM DIAM./
ASME ASME TAG NUMBER NDE DATE CAT ITEM NO SUFFIX CODE DESCRIPTION SYST METH TO DIAM.
REMARKS C-F-1 C5.11 NE-2-232 NOZZLE TO PIPE NE UT 091996 8.000 SOUTH END OF COND. B WELD ISI i
C-F-1 C5.11 NE-2-232 NOZZLE TO PIPE NE SUR 091996 8.000 SOUTH END OF COND. B WELD ISI C-F-1 C5.11 NZ-3-0002 TEE TO PIPE NZ SUR 083096 8.000 1" LINEAR IN BASE METAL. REPORTED O 4
WELD ISI N MNCE 96-45. DETERMINED NOT TO BE C-F-1 C5.11 NZ-3-0002 TEE TO PIPE NZ UT 8.000 WELD ISI C-F-1 C5.12 NZ-3-0002A LONGITUDINAL WELD ON PIPE NZ UT 082096 8.000 j
C-F-1 C5.12 NZ-3-0002A LONGITUDINAL WELD ON PIPE NZ SUR 082096 8.000 WELD ISI C-F-2 C5.51 NCS-2-0023 ELBOW TO PIPE NCS UT 082196 10.000 WELD ISI C-F-2 C5.51 NCL.-2-0023 ELBOW TO PIPE NCS SUR 081696 10.000 i
WELD ISI C-F-2 C5.51 NCS-2-0035 REDUCER TO ELBOW NCS SUR 081596 10.000 WELD ISI C-F-2 C5.51 NCS-2-0035 REDUCER TO ELBOW NCS UT 081696 10.000
)
WELD ISI C-F-2 C5.51 NCS-2-0049 TEE TO PIPE NCS UT 082096 10.000 WELD ISI C-F-2 C5.51 NCS-2-0049 TEE TO PIPE NCS SUR 082096 10.000 WELD ISI i4 C-F-2 C5.51 NQ-1-0018 ELBOW TO PIPE NQ UT 081696 12.000 I
WELD ISI C-F-2 C5.51 NQ-1-0018 ELBOW TO PIPE NQ SUR 081696 12.000 WELD ISI 1
C-F-2 C5.51 NO-1-0049 PIPE TO ELBOW NQ UT 081696 12.000 i
WELD ISI C-F-2 C5,51 NQ-1-0049 PIPE TO ELBOW NQ SUR 081696 12.000 WELD ISI 3
C-F-2 C5.51 NQ-2-0034 ELBOW TO PIPE NQ UT 081496 14.000 WELD ISI C-F-2 C5.51 NO-2-0034 ELBOW TO PIPE NQ SUR 081396 14.000 WELD ISI C-F-2 C5.51 NQ-2-0085 ELBOW TO PIPE NQ UT 081496 14.000 WELD ISI C-F-2 C5.51 NO-2-0085 ELBOW TO PIPE NQ SUR 081396 14.000 WELD ISI C-F-2 C5.51 NQ-2-0098 TEE TO PIPE NQ UT 081596 14.000 WELD ISI C-F-2 C5.51 NQ-2-0098 TEE TO PIPE NQ SUR 081596 14.000 WELD ISI O
9 9
-+s--,e-3-m+
i~
MIS-1 OWNERS DATA REPORT FOR INSERVICE INSPECTION DATE: 01/13/97 PAGE: 0010 1.
OWMER: Jersey Central, Power S Light Company, Madison Avenue &
Punch Bowl Road, Morristown, New Jersiley 2.
PLANT: Oyster Creek Nuclear Generating Station, U.S.
Route 9, Forked River, New Jersey 3.
PLANT UNIT: NA i
4.
OWNER CERTIFICATION OF AUTH ZATION (if required): None 5.
COMMERCIAL SERVICE DATE: 1
/69
- 6. NATIONAL BOARD NUMBER FOR
- Reactor Vessel 14895 d
OUTAGE 16R TABLE 1 IDENTIFICATION EXAM ASME ASME TAG NUMBER NDE DATE/
FROM DIAM./
CAT ITEM NO SUFFIX CODE DESCRIPTION SYST METH REASON TO DIAM.
REMARKS C-F-2 C5.51 NQZ-1-0033 REDUCING TEE TO PIPE NQZ UT 081496 20.000 WELD ISI C-F-2 C5.51 NQZ-1-0033 REDUCING TEE TO PIPE NQZ SUR 080996 20.000 WELD ISI C-F-2 C5.51 NZ-1-0034 PIPE TO ELBOW NZ UT 081396 12.000 WELD ISI C-F-2 C5.51 NZ-1-0034 PIPE TO ELBOW NZ SUR 080996 12.000 WELD ISI C-F-2 C5.51 NZ-1-0089 PIPE TO ELBOW NZ UT 081496 12.000 WELD ISI 1
C-F-2 C5.51 NZ-1-0089 PIPE TO ELBOW NZ SUR 080996 12.000 WELD ISI C-F-2 C5.51 NZ-2-0274 PIPE TO ELBOW NZ MT 082696 6.000 WELD AUG C-F-2 C5.51 NZ-2-0274 PIPE TO ELBOW NZ UT 082696 6.000 WELD AUG C-F-2 C5.51 NZ-2-0275 ELBOW TO PIPE NZ SUR 082696 6.000 WELD AUG C-F-2 C5.51 NZ-2-0275 ELBOW TO PIPE NZ UT 082696 6.000 WELD AUG C-F-2 C5.51 NZ-2-0288 PIPE TO ELBOW NZ SUR 082896 6.000 WELD AUG C-F-2 C5.51 NZ-2-0288 PIPE TO ELBOW NZ UT 082896 6.000 WELD AUG C-F-2 C5.51 RF-2-0093 PIPE TO ELBOW RF SUR 100196 18.000 WELD ISI C-F-2 C5.51 RF-2-0093 PIPE TO ELBOW RF UT 100196 18.000 WELD ISI C-F-2 C5.51 RF-2-0103 PIPE TO REDUCER RF SUR 091996 24.000 WELD ISI C-F-2 C5.51 RF-2-0103 PIPE TO REDUCER RF UT 092696 24.000 WELD ISI C-F-2 C5.81 RF-2-0086 PIPE TO BRANCH RF SUR 092296 24.000 i
WELD ISI C-F-2 C5.90 NZ-2-0276 PIPE TO ELBOW NZ UT 082696 6.000 WELD AUG 4
C-F-2 C5.90 NZ-2-0276 PIPE TO ELBOW NZ SUR 092596 6.000 ONE LINEAR INDICATION 1.2" LOCATED WELD AUG AT TOE OF WELD.
REPORTED ON C-F-2 C5.90 NZ-2-0277 ELBOW TO PIPE NZ UT 082696 6.000 WELD AUG C-F-2 C5.90 NZ-2-0277 ELBOW TO PIPE NZ SUR 082696 6.000 WELD AUG C-H C7.30 411 MAIN STEAM SYSTEM-PIPING MS VT-2 102396 PIPE ISI s
O
NIS-1 OWIEERS DATA REPORT FOR INSERVICE INSPECTION DATE: 01/13/97 PAGE: 0011 1.
OWEEER: Jersey Central Power & Light Company, Madison Avenue &
Punch Bowl Road, Morristown,,New Jersey 2.
PLANT: Oyster Creek Nuclear G nerating Station, 9
U.S.
Route 9, Forked River, New Jersey 3.
PLANT UNIT: NA I
4.
OWNER CERTIFICATION OF AUTHORIZATION (if required): None
- 5. COMMERCIAL SERVICE DATE: 12/23/69
- 6. NATIONAL BOARD NUMBER FOR UNIT: Reactor Vessel 14895 OUTAGE 16R TABLE 1 IDENTIFICATION EXAM ASME ASME TAG NUMBER NDE DATE/
FROM DIAM./
CAT ITEM NO SUFFIX CODE DESCRIPTION SYST METH REASON TO DIAM.
REMARKS l
C-H C7.30 422 FEEDWATER SYSTEM - PIPING RF VT-2 102396 PIPE ISI 1
C-H C7.40 214 CLASS 2 PORTION OF THE SH NU VT-2 090596 A-LOOP SYSTEM UTDOWN COOLING SYS AUG C-H C7.40 214 CLASS 2 PORTION OF THE SH NU VT-2 090596 B-LOOP SYSTEM UTDOWN COOLING SYS AUG C-H C7.40 214 CLASS 2 PORTION OF THE SH NU VT-2 090596 C. LOOP SYSTEM UTDOWN COOLING SYS AUG D-B D2.20 H-5-002 RB CLOSED COOLING WATER CC VT-3 082296 s
H-1 SUPORT HEAT EXCHANGER 1-2 ISI 4
j D-B D2.20 H-5-002 RB CLOSED COOLING WATER CC VT-3 082796 H-2 SUPORT HEAT EXCHANGER 1-2 ISI D-B D2.20 541-1035 ROD HANGER CC VT-3 082296 SUPORT (CC-3-H7)
ISI D-B D2.20 541 ".036 ROD HANGER CC VT-3 082296 1
SUPORT (CC-3-H8)
ISI D-B D2.20 541-1037 ROD HANGER CC VT-3 082296 SUPORT (CC-4-H11)
ISI D-B D2.20 541-1044 ROD HANGER CC VT-3 082296 SUPORT (CC-4-H18)
ISI D-B D2.20 541-1052 ROD HANGER CC VT-3 082296 SUPORT (CC-4-H26)
ISI l
D-B D2.40 541-1056 VARIABLE SPRING HANGER CC VT-3 082896 SUPORT (CC-4-H30)
ISI D-B D2.40 541-1057 VARIABLE SPRING HANGER CC VT-3 082896 SUPORT (CC-4-H31)
ISI D-C D3.20 P-18-001A 2 WELDED 1SUPORT ON SKID NN VT-3 082196 d
H-1 SUPORT PUMP (NN01-A)
ISI F-A F1.10 411-BP-X-2A-SS-1-0009 MECHANICAL SNUBBER S-1-1 MS VT-3 091796 LACK OF FULL THREAD ENGAGEMENT BACK A
SUPORT (MS-1-S13)
ISI END BOLT. REPORTED ON ER 96-31 USE F-A F1.10 411-BP-X-2A-SS-1-0009 MECHANICAL SNUBBEI! S-1-2 MS VT-3 091796 LACK OF FULL THREAD ENGAGEMENT. REP B
SUPORT (MS-1-S14)
ISI ORTED ON ER 96-32 USE AS IS F-A F1.10 411-1000 NEED DETAILED DWG.
MS VT-3 090796 SUPORT (MS-1-H12)
ISI F-A F1.10 225-BP-NC-4-R2-0003 CLAMP NC VT-3 091896 SUPORT (NC-4-H3)
ISI F-A F1.10 215-BP-ND-1-H2A-0015 VARIABLE SPRING HANGER ND VT-3 100296 SUPORT (ND-1-H4)
ISI F-A F1.10 223-GR-H3 (C) -0 02 7 l CONSTANT NG VT-3 091396 PIN READING AT END OF SCALE, LACK O A
SUPORT (NG-C-H1)
ISI F FULL THREAD ENGAGEMENT. AND DENTE F-A F1.10 223-GR-H3 (C) -0 02 7 CONSTANT NG VT-3 091396 B
SUPORT (NG-C-H2)
ISI F-A F1.10 213-BR-NP-2-H3-0011 VARIABLE SPRING HANGER NP VT-3 082896 SUPORT (NP-2-H8)
ISI 0
--_'e
WIS-1 OWNERS DATA REPORT FOR INSERVICE INSPECTIOE4 DATE: 01/13/97 i
PAGE: 0012
- 1. OWNER: Jersey Central Power & Light Company, Madison Avenue &
Punch Bowl Road, Morristown,,New Jersey 2.
PLANT: Oyster Creek Nuclear G9nerating Station, U.S.
Route 9, Forked River, New Jersey 3.
PLANT UNIT: NA
- 4. OWNER CERTIFICATION OF AUTH RIZATION (if required): None
- 5. COMMERCIAL SERVICE DATE: 1 23/69 6.
NATIONAL BOARD NUMBER FOR IT: Reactor Vessel 14895 OUTAGE 16R TABLE 1 l
IDENTIFICATION EXAM ASME ASME TAG NUMBER NDE DATE/
FROM DIAM./
CAT ITEM NO SUFFIX CODE DESCRIPTION SYST METH REASON TO DIAM.
REMARKS F-A F1.10 214-BP-X-7-SS-1-0006 MECHANICAL SNU3BER NU VT-3 091796 s
A SUPORT (NU-1-S3)
ISI F-A F1.10 214-BP-557-R11-0035 HYDRAULIC SNUBBER NU VT-3 121295 SUPORT (NU-2-S10)
ISI i
F-A F1.10 214-BP-557-R5-0025 HYDRAULIC ENUBBER NU VT-3 121295 SUPORT (NU-2-SS)
ISI F-A F1.10 212-BP-NZ-3-H1(B)-0003 VARIABLE SPRING HANGER NZ VT-3 091396 BENT I BEAM ON THE OUTER EDGES. THI SUPORT (NZ-3-H4)
ISI S WAS REPORTED ON ER 96-019 AND REV 4
F-A F1.10 212-BP-461-R3-0002 MECHANICAL SNUBBER NZ VT-3 091996 SUPORT (NZ-3-S3)
ISI i
F-A F1.10 212-BP-461-R4-0001 MECHANICAL SNUBBER N-20-4 NZ VT-3 091996 SUPORT (NZ-3-S4)
ISI F-A F1.10 422-BP-RF-R1-0020 MECHANICAL SNUBBER RF VT-3 091996 SUPORT (RF-2-S3)
ISI F-A F1.10 216-1000 VARIABLE SPRING CAN RHC VT-3 100696 SUPORT (RHC-2-H1)
ISI F-A F1.10 216-1002 NEED DETAILED DWG.
RHC VT-3 091796 SUPORT (RHC-2-H3)
VER F-A F1.20 225-SN-PSR-032-2-0028 GUIDE NC VT-3 082296 SUPORT (NCS-2-H21)
ISI F-A F1.20 211-BP-632-R4-0048 NE-1-12" HYDRAULIC PIPE NE VT-3 090796 SUPORT SNUBBER (NE-1-S12)
ISI F-A F1.20 241-BP-NQZ-T-H1(M-0108 SLIDE NQ VT-3 081696 1
SUPORT (NOZ-1-H11)
ISI F-A F1.20 241-BP-NQ-2-H3-0003 BPACKET NQ VT-3 091896 A
SUPORT (NQ-2-H65)
ISI F-A F1.20 241-BP-NQ-2-R4-0071 SWAYBAR NQ VT-3 081996 BENT ROD AND LOOSE NUT. REPORTED ON i
SUPORT (NQ-2-H32)
PSI ER 96-2 AND MNCR 96-57 ROD WAS REP F-A F1.20 241-BP-227-R1-0028 RIoED STRUT (SNUBBER REPLA NQ VT-3 100196 SUPORT CED WITH STRUT)
ISI F-A F1.20 241-BP-487-RS-0032 HYDRAULIC SNUBBER - 23/3 NQ VT-3 082296 SUPORT (NQ-2-S14)
ISI F-A F1.20 212-BP-NZ-2-H10-0008 VARIABLE SPRING HANGER (N NZ VT-3 SUPORT Z-3-H1)
ISI F-A F1.20 212-BP-368-R5-0021 HYDRAULIC SNUBBER NZ VT-3 081996 SUPORT (NZ-2-S3)
ISI F-A F1.20 212-BP-411-R2-0058 HYDRAULIC SNUBBER NZ VT-3 112895 hbbE ILED DWG.
RF VT-3 0 0796 SPRING CAN SETTINGS VERIFICATION. R F-A F1.20 422-1000 SUPORT (RF-2-H13)
VER EPORTED ON ER 96-003 SETTINGS ARE W F-A F1.20 422-1010 NEED DETAILED DWG.
RF VT-3 090796 SPRING CAN SETTING VERIFICATIONS. R SUPORT (RF-2-H21)
VER EPORTED ON ER 96-004 THE SETTINGS A 1
F-A F1.20 422-1013 NEED DETAILED DWG.
RF VT-3 090796 SUPORT (RF-2-H23)
ISI P
W w
e w
a yy t
- W r
- me *
-'-'er-
---g.-
v
-gMw-P
'-ee*
mm-'%e
PAGE: 0013
- 1. OWNER: Jersey Central Power & Light company, Madison Avenue &
Punch Bowl Road, Morristown,,New Jerpey 2.
PLANT: Oyster Creek Nuclear Generating Station, U.S.
Route 9, Forked River, New Jersey 3.
PLANT UNIT: NA
- 4. OWNER CERTIFICATION OF AUTH RIZATION (if required): None
- 5. COMMERCIAL SERVICE DATE: 12 23/69 6.
NATIONAL BOARD NUMBER FOR IT: Reactor Vessel 14895 OUTAGE 16R j
TABLE 1 IDENTIFICATION EXAM I
ASME ASME TAG NUMBER NDE DATE/
FROM DIAM./
CAT ITEM NO SUFFIX CODE DESCRIPTION SYST METH REASON TO DIAM.
REMARKS
[CE""pi[36" '555-5b5b
~~~
UbiUE
"~~
UU~~Vi25~bb2996~
~~
~~
~
SUPORT (CC-4-H4D)
ISI F-A Pl.30 541-1044 ROD HANGER CC VT-3 082296 i
SUPORT (CC-4-H19)
ISI F-A F1.30 424-1015 STANCHION CH VT-3 090796 SUPORT (CH-5-H14)
ISI F-A F1.30 251-0029 ROD HANGER NN VT-3 082196 SUPORT (NN-1-H1)
ISI i
F-A F1.30 531-1009 ROD HANGER SW VT-3 081696 SUPORT ISI F-A F1.30 531-1011 ROD HANGER SW VT-3 082996 i
SUPORT VER 1
F-A F1.30 531-1012 ROD HANGER SW VT-3 082996 SUPORT VER F-A F1.30 531-1022 NEED DETAILED DWG.
SW VT-3 081696 THIS COMPONENT SHALL BE RE-SCHEDULE i
SUPORT VER D FOR 17R F-A F1.30 532-BR-SW-2-H14A-0058 SLIDE SWE VT-3 090796 i
l SUPORT (SW-2-H35)
ISI F-A F1.40 H-5-002 RB CLOSED COOLING WATER CC VT-3 082196
+
H-1 SUPORT HEAT EXCHANGER 1-2 ISI F-A F1.40 H-5-002 RB CLOSED COOLING WATER CC VT-3 082296 H-2 SUPORT HEAT EXCFANGER 1-2 ISI F-A F1.40 22 3 -GR-H1 (C) - 0 0 3 0 CONSTANT NG VT-3 091096 A
SUPORT (NG-C-H4)
ISI F-A F1.40 2 23 -GR-H1 (C) - 0 03 0 QNSTANT NG VT-3 091096 B
SUPORT (NG-C-H5)
ISI F-A F1.40 22 3 -GR-H1 ( C) - 0 03 0 CONSTANT NG VT-3 091096 C
SUPORT (NG-C-H6)
ISI t
F-A F1.40 223 -GR-H1 (C) - 0 03 0 CONSTANT NG VT-3 091096 D
SUPORT (NG-C-H7)
ISI F-A F1.40 P-18-001A 2 WELDED 1SUPORT ON SKID NN VT-3 032196 1
H-1 SUPORT PUMP (NN01-A)
ISI F-A F1.40 P-18-001C AUG SPENT FUEL POOL PUMP NN VT-3 082196 i
H-1 SUPORT SUPORT ISI i
F-A F1.40 D:G-001C AUG SPENT FUEL POOL PUMP NN VT-3 082196 l
.a-2 SUPORT SUPPORT (NN01-C)
ISI F-A F1.40 P-20-002B CORE SPRAY BOOSTER PUMP 2 NZ VT-3 082296 H-1 SUPORT WELEED 1 SUPPORT ON SKID ISI i
F-A F1.40 221-0500 RX HOZ STABILIZER RX VT-3 091796 A
SUPORT ISI F-A F1.40 221-0500 RX HOZ STABILIZER RX VT-3 091796 B
SUPORT ISI F-A F1.40 221-0501 RX HOZ STABILIZER RX VT-3 091796 A
SUPORT ISI s
T
---,w.,4-
-3, 9-4y- -..,.,-e-
- t" 7---'*-T-ammW
-t ww---
ww'-
e v ve -
's4'-
a
---t
- * * - '-M-'--m*
-Vm'-
T-'--T-1 T
"-'VP~7*s
NIS-1 OWNERS DATA REPORT FOR INSERVICE INSPECTION DATE: 01/13/97 PAGE: 0014
- 1. OWNER: Jersey Central Power & Light Company, Madison Avenue &
Punch Bowl Road, Morristown, New Jergey 2.
PLANT: Oyster Creek Nuclear Generating Station, U.S.
Route 9, Forked River, New Jersey 3.
PLANT UNIT: NA
- 4. OWNER CERTIFICATION OF AUTH RI TION (if required): None 5.
COMMERCIAL SERVICE DATE: 1 23 69
- 6. NATIONAL BOARD NUMBER FOR IT Reactor Vessel 14895 OUTAGE 16R TABLE 1 i
IDENTIFICATION EXAM ASME ASME TAG NUMBER NDE DATE/
FROM DIAM./
CAT ITEM NO SUFFIX CODE DESCRIPTION SYST METH REASON TO DIAM.
REMARKS F-A F1.40 221-0501 RX HOZ STABILIZER RX VT-3 091796 i
B SUPORT ISI F-A F1.40 221-0502 RX HOZ STABILIZER RX VT-3 091796 A
SUPORT ISI F-A F1.40 221-0502 RX HOZ STABILIZER RX VT-3 0917 %
1 B
SUPORT ISI F-A F1.40 221-0503 RX HOZ STABILIZER RX VT-3 091796 A
SUPORT ISI F-A F1.40 221-0503 RX HOZ STABILIZER RX VT-3 091796 I
B SUPORT ISI 4,e-tra.1d.
= ICCCC 00.11
!TJ 1 0001 V."J VC TO PIPC
!PJ L7 gy400 14.000 NW 1
^'~
ht/2 //is/97 a
i r
a 4
NIS-1 TABLE 2 REFUELING OUTAGE 16R EXAM CATEG ITEM COMPONENT SYSTEM METHOD REMARKS NO.
ORY NO.
DESCRIPTION 2990 B-F B5.10 NR02 2-565E WELD 221 SUR Two indications were detected by dye penetrant. Indication (1) was NOZZLE TO SAFE END rounded,7/16 inch. ans indication (2) was hnear,5/8/ inch. The indications were determined to be caused by presious mechanical work on the OD. Both indications were removed by light filing. A re-examination was performed and accepted.
3113 B-J B9.12 t'-Z-3-0034B WELD 212 SUR An indication 1.75 inches in length was recorded by dye penetrant. The INTRADOS OF ELBOW indication had the appearance of having been blended. The indication was in the bade material of the elbow. In accordance with Section XI paragraph IWB-3514.3(b), a ut examination was performed and determined the indication acceptable per Table IWB-3514-2. This weld was re-scheduled for examination during the next refueling outage 17R.
658 B-J B9.32 NG-A-000A WELD 223 SUR Ten surface indications were detected by dye penetrant. Seven ELBOW TO BRANCli indications were classified as linear, and three were rounded. The 2*OD acceptance criteria from Section XI Table IWB-3514-2 is 0.25 inches in length for u all thickness between 1.00 inche to less than 2.00 inches.
The seven knear were all within the allowable for base material 1.219 inches. The rounded indications were also determined to be acceptable.
This weld was re-scheduled for examination during the next refueling outage 17R.
1779 C-F-1 C5.11 NZ-3-0002 WELD 212 SUR A shallow indication 1.00 inches knear was detected by dye penetrant in TEE TO PIPE the base metal on the tee. This indication was determined to be nim service induced. In 10 mils increments the indication was removed by grindmg and IFT exams. A UT thickness was performed to venfy remaining walt 4122 C-F-2 C5.90 NZ-2-0276 WELD 212 SUR A shallow indication 1.2 inches linear was detected by magnetic particle PIPE TO ELBOW at the toe of the weld. This indication was removed by hand filing.
I13 F-A F1.10 212-BP-NZ-3-lil(B)-0003 212 VT-3 (1) Lock nut loose against top of sprmg can. (2) i Beam is bent do* n on VARIABLE SPRING upper outer edges both sides of beam. Item (1) loose lock nut was hand FLANGER tighten. Item (2) was determined to be cause by use of chain fall to hfe valve v-2(M)017. Review of the support calculations, C-1302-212-5320-025 Rev. 3 Sheets 27 to 36, determined that the maximum stress in the support is approx. 20% of the allowable stress. By review of the support drawing it was determined that the location of the bent flanges was not the entical stress hication. The stresses are much lower at the interior h> cation. Since the bends occurred at the outer edges only a porti m of the flange was determined to be effective to resist bendmg. The support was determined to be acceptable for service. This support was re-scheduled for exanunation during the next refuelmg 17R.
'2291 F-A Fl.20 241-BP-NQ-2-R4-0071 241 VT-3 Bent threaded rmi. The rod is oriented in the honzontal. Root cause SWAY BAR evaluated was deternuned to be externalinfluence. The rmt was replaced.
I
6730-97-2038 ATTACIIMENT II i
i I
NIS-2 FORMS OYSTER CREEK NUCLEAR GENERATING STATION REFUELING OUTAGE 16R
FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. owner Jersey Central Power & Light
- oog, January 19, 1997 Madison Ave. & PunchtfW1 Rd.
Morrist.own, N.J.
07960 Sheet of Address
- 2. Plant 0vster Creek Nuclear Generating Station unit Oyster Creek Name U.S. Hwy.9 Forked River, N.J.
08731
_Sec_auached job numher._
Address Repair organiz ation P.O. No., Job No.. etc.
- 3. Work Performed by CPU Nuclear Corp. oration Type Code symbol Stamp N/A Authorization No.
N/A One_Uppcr_Psnd_Rd. a_Earsippany LJ _Q]054 Expiration Date N/A Address
- 4. Identification of System See attached
- 5. (a) Applicable Construction Code B31.1 19 55 go,t;on, N/A
- Addenda, N/A code case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 86
- 6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National
- epaired, Stamped Name of Name of Manufacturer Board Other
- Replaced, (Yes Component Manufacturer Serial No.
No.
Identification Built or Replacement or No) 1 i
/
r Replacemens
- 7. Description of Work
- 8. Tests Conducted: Hydrostatic Pneumatic 0 Nominal Operating Pressure @
Other O Pressure psi Test Temp.
'F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of shee+s is recorded at the top of this form.
(12/82)
This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017
=
o.
FORM NIS 2 (Back)
- 9. Remarks.The n t enchmon t ia n 14ar nf TsT cnmnnnonra ehne ronnirod n PRT ovnminneinn Applicable Manufacturer's Data Fieports to be attached after replacement.
CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this N/A conforms to the rules of the
P*i'*PC'**"*
ASME Code,Section XI.
Type Code Symbol StampdQRe None Certificate of Authorization No.
Expiration Date N/A Signed M
' /b/
M Date 19 wne or Owner's signes, Title y
v CERTIFICATE OF INSERVICE INSPECTION t, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province ofjew Jersey and employed by H.S.B.I.&I Company of Hartford d t.
have inspected the components described in this Owner's Report during the period 12/lb/94 10/22/96
. and state that to to the best of my knowiedge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property dama0e or a loss of any kind arising from or connected with this inspection.
Commissions NB5478(I) (NINJ442 inspector's Signathe National Board, State, Province, and Endorsements Date df SI 19 (12/82) l I
l 1
l
NIS-2 OWNER'S REPORT FOR REPAIRS AND REPLACEMENT
~
2 OYSTER CREEK'S REFUELING 16R
. r CONTROL COMPONENT CATEGORY SYSTEM RESIARKS DOCUMENT ITEMNO NO.
J.O.501725 V-1-0160 6"
B-G-2 411 Removed, and replaced with new bolts. A PSI VT-1 BONNET BOLTING
^
- * * * " " " *** P*
J.O.501725 V-1-0163 6"
B-G-2 411 Removed, and replaced with new bolts. A PSI VT-1 BONNET BOLTING
- * * * " " "*** F' '*
3.0.501725 V-1-0173 6"
B-G-2 411 Removed, and replaced with new bolts. A PSI VT-1 B7.70 examination was performed. Maintenance BONNET BOLTING J.O.501725 V-t-0174 6"
B-G-2 411 Removed, and replaced with new bolts. A PSI VT-1 B7.70 examination was performed. Maintenance BONNET BOLTING J.O. 501725 V-1-0177 6"
B-G-2 411 Removed, and replaced with new bolts. A PSI VT-1 B7.70 examination was performed. Maintenance BONNET BOLTING J.O. 510073 NG-E-BG001 2" B-G-2 223 after video examination through the 2" Decon
" F*"S#'
'.f reign intrusion within the BONNET BOLTING Reactor Recirculation pipmg. Studs and nuts were replaced and VT-1 examined MNCR 96-57 241-BP-NQ-2-R4-0071 F-A 241 Rod was reported bent during an ISI examination, Fl.20 The rod was replaced and VT-3 examined l
SWAYBAR SUPPORT I
=
t
\\
l
[
s 3
4 1
1 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner _JpIggy_Gentral P.pwer & Light oate _ January _lh 1997 Madison Ave. & PunEt h i Rd.
Morristowna_N.d._D196D Sheet of Address
- 2. Plant Oyster Creek Nuclear Generating Stationunit Oyster Creek Name U.S. Hwy. 9 Forked River, N.J. 08731 See attached job number Ad dress Repair Organization P,o, No., Job No., etc.
N/A i
- 3. Work Performed by GPU Nuclear Corporation Type Code symbol Stamp Authoriistion No.
N/A One Upper Pond Rd., Parsippany. N.J. 07054 Expiration oste N/A Ad dress
- 4. Identification of System _._,See attached
- 6. (a) Applicable Construction Code R 'll_.1 19 55
- Edition, N/A Addenda, N/A code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19.. 86 i
- 6. Identification of Components Repaired or Replaced and Replacement Components d
Code National
- epaired, Stamped Name of Name of Manufacturer Board Other
- Replaced, (Yes Component Manufacturer Serial No.
No.
Identification Built or Replacement or No)
I
- 7. Description of Work Replacements
- 8. Tests Conducted: Hydrostatic 0 eneumatic 0 Nominal Operating Pressure h Other Pressure psi Test Temp.
- F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82)
This Form (E00030) may be obtained from the Order Dept., ASME,345 E 47th St., New York, N.Y.10017
e a
l FORM NIS 2 (Back)
- 9. Remarks The attachment is a list of maintenance activities that were performed Applicable Manufacturer's Data Reports to be attached on ISI components. This work was controlled by our job order tracking system.
1 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code, Section Xl.
P*P'***'"*"*
None Type Code Symbol Stamp Certificate Authorization No.
None Expiration Oate N/A 199 7 signed M
Date dwner or owner's D ignes, Titie Q
l
]
U CERTIFICATE OF INSERVICE INSPECTION i, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of New Jersev and employed by H.S.B.I.&.T. Comnnny of Hartford. Ch have inspected the components described in this Owner's Report during the periodM/_16 /95 to IO/79/05
. and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASVE Code,Section XI.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising f rom or connected with this inspection.
J Commissions NR9A7R(T) (N)NTAA7 in pector's Sig ture National Board, State, Province, and E ndorsements Date 4h
- Il 1997 (12/82)
. - _.. ~. - -
NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT 2
OYSTER CREEK REFUELING OUTAGE 16R JOB COMPONENT SYSTEM CODE REMARKS ORDER CLASS 57358 V-1-0144, 411 2
Vale was replaced with a new % inch handcock globe valve. This work was considered VALVE corrective maintenance 59778 V-1-0289, 1*
411 2
Valve was replaced along with piping. Maintenance VALVE j
62679 V-20-0072, 1'
212 2
Valve was replaced. Maintenance VALVE 57752 V-19-0022, l'
213 2
Valve V-19-22 was replace and relocated V-19-49 was rotated, VALVE V-190049, 213 1
VALVE 64209 V-3-0133, 2'
532 3
Valve was replaced with new. Maintenance 505280 VALVE 507942 64227 V-3-0131, 2-532 3
Valve was replaced with new. Maintenacne l
500905 VALVE 508048 64013 V-20-0159, 212 2
Weld repair leaking % line on up stream of vlave. Leak was located where instrument line VALVE enter weldolet. maintenance 63562 V-18-0012, 251 3
Valve was replaced by welding with new. Valve is the drain from fuel pool heat exchanger VALVE H-18-001 A Maintenance 62740 V-20-0073, 1"
212 2
Valves were replaced by welding. Configuration changed VALVE V-20-0102, 1'
212 2
i VALVE 62302 V-18-0113, 251 3
Valve was replaced by welding with new.
VALVE i
500461 UNDER GROUND PIPING 424 3
Under ground piping was replaced by welding with new. Corrective maintenance 500463 6" AND 10* ALUMINUM 502406 422-BP-X-4A-SS-1-0027 A 422 1
Forty-three mechanical snubbers were replaced Maintenance l
422-BP-X-4A-SS-1-0027 B 422 1
422-BP-RF-R6-0024 422 1
422-BP-RF-R4-0021 422 1
422-BP-RF-R1-0020 422 1
t 422-BP-RF-R2-0017 422 1
422-BP-RF-R3-0018 422 1
422-BP-RF-R6A-0009 422 1
4C BP-RF-R4A-0006 422 1
422-BP-R F-R1 A-0005 422 1
422-BP-RF-R2A-0002 422 1
422-BP-RF-R3A-0003 422 1
211-BP-634-R16-0002 211 1
211-BP-634-R15-0004 211 1
(
211-BP-X-58-SS-1-0005 211 1
211-BP-634-R14-0022 211 1
I f
= - -
I NIS-2 CWNER'S REPORT FOR REPAIRS CR REPLACEMENT OYSTER CREEK REFUELING OUTAGE 16R JOB COMPONENT SYSTEM CODE REMARKS ORDER CLASS 502406 211-BP-634-R13-0023 211 1
Forty-three mechanical snubbers were replaced. Maintenance, 211-BP-X-SA-SS-1-0025 A 211 1
211-BP-X-5A-SS-1-0025 B 211 1
211-BP-X-38-SS-1-0039 8 211 1
215-BP-X-10-SS-1-0014 A 215 1
214-BP-X-8-SS-1-0019 A 214 1
214-BP-556-R2-0002 214 1
214-BP-556-R1-0004 214 1
214-BP-X-7-SS-1-0006 A 214 1
214-BP-X-7-SS-1-0006 B 214 1
251-0053 251 1
212-MP-N1-0163 212 1
212-MP-N2-0105 212 1
212-MP-S2-0158 212 1
223-GR-SS-1(A)-0009 B 223 1
223-GR-SS-2(A)-0010 A 223 1
223-GR-SS-1(B)-0020 B 233 1
223-GR-SS-2(B)-0021 A 233 1
223-GR-SS-1(C)-0031 B 233 1
223-GR-SS-2(C)-0032 A 233 1
223-GR-SS-2(C)-0032 B 233 1
223-GR-SS-1(D)-0042 A 233 1
223-GR-SS-1(D)-0042 8 233 1
223-GR-SS-2(D)-0043 A 233 1
223-GR-SS-2(D)-0043 B 233 1
223-GR-SS-1(E)-0053 A 233 1
-223GR-SS-1(E)-0053 8 233 1
508644 S0-305-0120, %'
225 2
Solenoid Valve for 30-11 HCU was replaced VALVE 508188 V-3-0082, 532 3
Relief valves for containments heat exchanger 1-1, and 1-2 were replaced This work was VALVE considered corrective maintenance V-3-0083, 532 3
VALVE V-21-0021, 241 2
VALVE V-21-0022, 241 2
VALVE 63534 V-20-0006, 212 2
Valve was replaces by welding. This work was considered corrective maintenance. Valve VALVE is drain for Pump NZO1-A 507355 V-1-0188, l'
411 2
Valve was replaced by welding This work was considered corrective maintenance VALVE 506745 V-20-0166, 212 2
Valve was replaced by welding Maintenance VALVE 63974 V-20-0262, 6"
212 2
Installed new vacuum breaker assembly by welding. This work was considered VALVE configuration change 2
t NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT OYSTER CREEK REFUELING OUTAGE 16R JOB COMPONENT SYSTEM CODE REMARKS
~ ORDER CLASS 509769 V-305-0107, 225 2
Valve was replaced due to leakage.
VALVE 501450 V-2-0071, 18" 422 1
Weided repair was performed VALVE 508863 V-20-0028, 4-212 2
Insta!! support for this valve by welding.
VALVE 506699 V-19-0023, 1 %-
213 2
Valve was replaced with new by welding.
VALVE 506359 V-11-0226, 424 3
Valve was replaced by welding VALVE 501449 V-21-0020, 1*
241 2
Valve was replaced VALVE 509049 V-21-0023, 241 2
Valves were replaced Maintenance VALVE V-21-0024 241 2
VALVE 503522 411-0182 6-411 2
A section of the deaerating steam piping was abandoned in place. This was a new weld WELD added to the system 505502 V-1-0350, 411 2
Valve was replaced by welding This work was considered configuration change VALVE 3
- -