MONTHYEARML20100P0701984-11-26026 November 1984 Forwards Rev 1 to Work Plan for Public Svc Co of Colorado for Mgt Consulting Svc, for Review & Comment.Schedule Being Implemented by NUS Listed Project stage: Other ML20100P0741984-11-27027 November 1984 Rev 1 to Work Plan for Public Svc Co of Colorado for Mgt Consulting Svcs Project stage: Other ML20099G6371985-01-30030 January 1985 Analysis & Evaluation of Mgt of Nuclear-Related Activities of Public Svc Co of Colorado Project stage: Other ML20128N3931985-02-12012 February 1985 Issue 2 to Policy 18, Fitness for Duty Policy. Guideline 18-1 Also Encl Project stage: Request ML20099G5981985-02-28028 February 1985 Forwards NUS 850130 Analysis & Evaluation of Mgt of Nuclear-Related Activities of Public Svc Co of Colorado & Resultant 850228 Action Plan Addressing Rept Recommendations Project stage: Other ML20099G6181985-02-28028 February 1985 Action Plan to Address Recommendation of NUS Rept Entitiled, Analysis & Evaluation of Mgt of Nuclear-Related Activities of Public Svc Co of Colorado Project stage: Other ML20113B7581985-03-29029 March 1985 Forwards Performance Enhancement Program,Project Details & Summary Schedule, Encompassing Recommendations of Mgt Assessment Rept,Nrc Concerns,Areas Needing Improvement & Corrective Actions Project stage: Other ML20113B7791985-03-29029 March 1985 Performance Enhancement Program,Project Details & Summary Schedule Project stage: Other ML20128N7411985-05-22022 May 1985 Responds to 850419 Request for Addl Info Re Util Performance Enhancement Program.Formal Shift Turnover Procedure Written & in Place.Review of in-place Control Room Tags Completed. Illegible Tags Replaced W/New Tags Project stage: Request ML20129C2791985-06-25025 June 1985 Performance Enhancement Program for Fort St Vrain Nuclear Generating Station Project stage: Other ML20129C2201985-06-25025 June 1985 Responds to SALP Rept for Oct 1984 - Feb 1985.Nuclear Performance Enhancement Program Provided at 850529 SALP Meeting Encl.Program Includes Organizational Changes & Activities in Progress Project stage: Meeting ML20133N9931985-07-31031 July 1985 Discusses Action Plan Detailed by Performance Enhancement Program (Pep) Outlining Preventive Maint Program.Pep Sub-Project III-3 Predicts Resources Necessary to Develop Program Project stage: Other ML20133D4841985-10-0303 October 1985 Staff Evaluation of State of Co PSC Plans to Enhance Mgt of Fort St Vrain Activities Project stage: Other ML20133D4671985-10-0303 October 1985 Forwards Staff Evaluation Re Response to Oct 1984 Assessment Rept,Nus Mgt Audit & Systematic Evaluation of Licensee Performance Rept for 1984.Info Should Be Provided in Third Quarterly Status Rept on Performance Enhancement Program Project stage: Other ML20138H6851985-10-21021 October 1985 Forwards Status Rept for Performance Enhancement Program for 850603-0930,per SALP 850529 Meeting Commitment Project stage: Meeting ML20137M1251985-12-20020 December 1985 Vol 1 to Audit of Fort St Vrain Performance Enhancement Program Project stage: Other ML20137M0961986-01-15015 January 1986 Forwards Performance Enhancement Programs Status Rept for 851001-860103, Per Commitment from 850529 SALP Meeting. Audit of Program ENG-3, Control of Design Document Encl Project stage: Meeting ML20137M1031986-01-15015 January 1986 Performance Enhancement Program Status Rept - as of 860103 Project stage: Other ML20142A0661986-03-14014 March 1986 Summary of 860116 Meeting W/Util,Training Co,Inc & SM Stoller Corp Re Performance Enhancement Program. Viewgraphs Encl Project stage: Meeting ML20237G4471986-04-30030 April 1986 Notification of 860509 Meeting W/Util & Training Co,Inc in Arlington,Tx to Discuss Util Performance Enhancement Program Project stage: Meeting ML20197J5451986-05-0909 May 1986 Forwards Performance Enhancement Program Status Rept for Jan-Mar 1986,per 850529 SALP Meeting Commitment Project stage: Meeting 1985-02-28
[Table View] |
Text
.
PublicService em s..
Company of Colorado 16805 WCR 19 1/2, Platteville, Colorado 80651 July 31, 1985 Fort St. Vrain Unit No. 1 P-85270 l
El Regional Administrator
.i I
Region IV AUG - 51985 U. S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 1000 Arlington, Texas 76011 Attn:
Mr. E. H. Johnson Docket No. 50-267
SUBJECT:
PREVENTIVE MAINTENANCE PLANNING AND SCHEDULING
REFERENCE:
PSC letter, 0. R. Lee to R. D. Martin, dated March 29, 1985 (P-85107)
Dear Mr. Johnson:
Public Service Company of Colorado has submitted an action plan detailed by the Performance Enhancement Program (PEP) which outlined a phased program for improvement of the Fort St. Vrain Preventive Maintenance Program (P-85107).
The objective of PEP Sub-Project III.3; " Develop Preventive Maintenance Engineering, Part 1 - Initial Definition" was to define the scope of the preventive / predictive (PM) maintenance program and predict the resources necessary to develop the program.
A significant component list has been developed which lists all components whose failure has the potential to cause significant moisture ingress into the core or restrict the plant capacity factor to a value below 100%.
This list is composed of two sublists, components wh.ose failure alone could potentially cause the above consequences (single failure components), and components whose failure accompanied by a failure of another component could potentially cause one of the above consequences (multiple failure components).
r, pP 8508140093 850731
((b gDR ADOCK 0500 7
jf
\\)
E i
k The significant component list for mechanical and electrical components was reviewed by the Plant Engineering staff to determine which of the listed significant components have historically been maintenance problems or have otherwise resulted in operational problems.
A sublist was created containing these components called the Critical Significant Component list. The components in this list will be considered priority items in establishing the preventive / predictive maintenance program.
With respect to mechanical and electrical components, an estimated one hundred and forty (140) unique " critical significant components" were identified as not being addressed by the current preventive maintenance program.
In addition, an extensive review of the existing three hundred and ten (310) preventive and corrective maintenance procedures (which are being revised per Part 2 of this sub project) has revealed the potential need for approximately two hundred and twenty (220) more procedures to provide completeness.
The existing preventive and corrective maintenance procedures are scheduled to be revised by January 3, 1986, as stated in the referenced letter.
Based on a start date of January 6,1986, the additional one hundred and forty (140) new and two hundred and twenty (220) supplemental procedure's identified above should be completed by December 31, 1986.
The performance of the remaining components on the Significant Component List will be reviewed periodically using failure trend analysis to identify additional preventive maintenance requirements as the program progresses.
If you have any questions, please contact Mr. M. H. Holmes at (303) 571-8409.
Sincerely, bM* by @ &iSt J. W. Gahm Manager, Nuclear Production Fort St. Vrain Nuclear Generating Station JWG:PJH/dr E--