_

~_

Oregon State University TRIGA Reactor Annual Report To satisfy the requirements of:

A.

U.S. Nuclear Regulatory Commision, License No. R-106 (Docket No. 50-243),

Section 6.7(e) of the Technical Specifications, for the reporting period July 1,1984 through June 30, 1985.

B.

U.S. Department of Energy, University Reactor Fuel Assistance Contract No. DE-AC06-76-ER01953, for the reporting period July 1,1984 through June 30, 1985.

C.

Oregon Department of Energy, OD0E Rule No.30-010, for the reporting period July 1,1984 through June 30, 1985.

Written by:

T. V. Anderson, Reactor Supervisor B. Dodd, Assistant Reactor Administrator D. S. Pratt, Radiation Specialist A. G. Johnson, Assistant Director, Radiation Center Submitted by:

C. V. Smith, Jr.

Reactor Administrator & Director, Radiation Center Radiation Center Oregon State University Corvallis, Oregon 97331 1

Telephone: 503-754-2341 h(

September 15, 1985 h

h\\

,7

- - - _ - - - _. - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ^ ~ - - - - - - - ' ~ ~ - ' ~

^

l Table of Contents PART 1 -- INTRODUCTION AND SUMARY Page A.

INTRODUCTION TO THE OREGON STATE TRIGA REACTOR (OSTR) ANNUAL REPOR 1-1 B.

SUMMARY

OF OSTR USE DURING THE REPORTING PERIOD....................

1-1 C.

SUMMARY

OF RADIATION CENTER LAB PERI0D.........................

ORATORY USE DURING THE REPORTING 1-2 D.

SUMMARY

OF OSTR ENVIRONMENTAL AND RADI ATION PROTECTION DATA......

1-3 1.

L i q u i d Wa s t e Da t a...............................................1-3 2.

Gaseous Waste Data..............................................

1-4 3.

S o l i d Wa s t e Da t a................................................

1 - 4 4.

Radiation Exposure Received by Facility Personnel and Visitors

( i n m re m )......................................................

1 - 5 5.

Number of Area and Offsite Environmental Monitoring Samples Evaluated.......................................................

1-5 PART 2 -- GENERAL INFORMATION A.

RADIATION CENTER....................................................

2-1 B.

FACULTY MEMBERS RESIDING AT THE RADI ATION CENTER................

2-2 C.

RESEARCH PERSONNEL USING RADIATION CENTER FACILITIES............

2-3 1.

Post-Doctora te Resea rch Associa tes..............................

2-3 2.

S c i e n t i s t s a n d Tra i n ee s.........................................

2-3 3.

G ra d ua t e S t ude n t s...............................................

2-6 D.

CLASSIFIED STAFF AT THE RADIATION CENTER...........................

2-7 E.

REACTOR OPE RATI ONS STAFF.........................................

2-8 F.

REACTOR OPERATIONS COMMITTEE........................................

2-8 G.

RADI ATION SAFETY COMMITTEE........................................

2-9

PART 3 -- 05TR OPERATIONAL DATA A.

BRIEF CHRON0 LOGY OF THE OSTR OPERATING HIST 0RY......................

3-1 B.

OPE RATI NG STATIST I CS................................................

3-2 C.

EXPERIMENTS PERF0RMED...............................................

3-2 D.

UN P LA N N E D S HU T D 0WN S.................................................

3-3 E.

CHANGES TO THE FACILITY, TO FACILITY PROCEDURES, AND TO REACTOR EXPERIMENTS PURSUANT TO 10 CFR 50.59................................

3-4 1.

Introduction............................................

3-4 2.

10 CFR 50.59 Changes to the Facility............................

3-4 a.

Installation of an Annunciator on the Ventilation Fan for the Argon Venti la tion System............................

3-4 b.

Electronic Timing Device for Measuring Control Rod Drop Times..................................................

3-6 c.

Change in the Display locations for Data from the Instrumented Fuel Element The rmocouple s.....................

3-7 3.

10 CFR 50. 59 Changes to Facili ty Procedures.....................

3-7 Revisions to the OSTR and Radiation Center Emer a.

Response Plan..................................gency 3-8 4.

10 CFR 50.59 Changes to Reactor Experiments.....................

3-9 a.

Change to Experiment B-24-Revised to Add Subpart B-24F......

3-10 5.

Forthcoming Changes to Be Made Under 10 CFR 50.59...............

3-11 F.

SURVEILLANCE AND MAINTENANCE........................................

3-11 1.

Non-Routine Maintenance.........................................

3-11 2.

Routine Surveillance and Maintenance............................

3-12 G.

REPORTABLE OCCURRENC ES..............................................

3-12

PART 4 -- OSTR UTILIZATION DATA A.

TEACHING PROGRAMS THAT UTILIZED THE 0STR............................

4-1 B.

RESEARCH PROJECTS THAT UTILIZED THE 0STR............................

4-2 C.

PUBLICATIONS RESULTING FROM RESEARCH USING THE 0STR.................

4-2 1.

Publications in Print...........................................

4-2

2. Theses..........................................................

4-4 3.

Reports Submi tted for Publication............................... 4-4 D.

PRESENTATIONS AT PROFESSIONAL MEETINGS RESULTING FROM RESEARCH USING THE OSTP AND FROM OSTR OPERATIONS.............................

4-5 E.

P U B L I C RE LAT I O N S.................................................... 4 - 5 F.

PLANNED CHANGES IN OSTR UTI LI ZATION................................. 4-6 PART 5 -- OSTR ENVIR0lWENTAL AND RADIATION PROTECTION DATA A.

INTRODUCTION........................................................

5-1 B.

A

SUMMARY

OF THE NATURE AND AMOUNT OF RADI9 ACTIVE EFFLUENTS RELEASED OR DISCHARGED TO THE ENVIRONS BEYOND THE EFFECTIVE CONTROL OF THE LICENSEE, AS MEASURED AT OR PRIOR TO THE POINT OF SUCH RELEASE OR DISCHARGE........................................5-1 1.

Liquid Waste (Summa rized on a Monthly Basis )....................

5-1 The radioactivity discharged during the reporting period a.

based on the following:.....................................

5-1

1) The total estimated quantity of radioactivity released (to the sanitary sewer) (in curies).....................

5-1

2) The detectable radionuclides present in this waste......

5-1

3) An estimate of the specific activity for each detectable radionuclide present, if the specific activity of the released material after dilution was greater than 1 x 10-' microcuries/ cubic centimeter...................

5-2

1

4) A summary of the total release (in curies) for each radionuclide identified in 2) above for the reporting period, based on representative isotopic analysis.......

5-2

5) The estimated average concentration of the released radioactive material at the point of release for the reporting period (in terms of microcuries/ cubic centimeter) and the fraction of the a MPC value............................pplicable 5-2 b.

The total volume (in gallons) of effluent water (includin diluent) released during each period of release..........g 5-2 2.

Gaseous Waste (Summarized on a Monthly Ba si s)...................

5-2 The radioactivity discharged during the reporting period a.

based on the following:.....................................

5-2

1) The total estimated quantity of radioactivity released (in curies) determined by an ap counting method................propriate sampling and 5-2
2) The detectable radionuclides present in this waste......

5-2

3) The total estimated quantity of argon-41 released during the reporting period (in curies), based on data from an appropri a te moni tori r.g sys tem...........................

5-2

4) The estimatad averagc atmospheric diluted concentration of argon-41 released during the reporting period (in terms of microcuries/ cubic centimeter) and the fraction of the applicable MPC value.............................

5-2

5) The total estimated quantity of radioactivity in particulate form with half-lives greater than eight days released during the reporting period (in curies),

as determined by an appropriate particulate monitoring system..................................................5-2

6) The average concentration of radioactive particulates with half-lives greater than eight days released during the reporting period (in microcuries/ cubic centimeter)..

5-3

7) An estimate of the average concentration of other significant radionuclides present in the gaseous waste discharge (in terms of microcuries/ cubic centimeter) and the fraction of the applicable MPC value for the reporting period, if the estimated release was than 20% of the applicable MPC................. greater 5-3

3.

Solid Waste (Summarized on an Annual Basis).....................

5-3 a.

The radioactivity discharged during the reporting period based on the following:.....................................

5-3

1) The total amount of solid waste packaged (in cubic feet). 5-3
2) The detectable radionuclides present in this waste......

5-3

3) The total radioactivity in the solid waste (in curies)..

5-3 b.

The dates of shipment and the disposition of solid wastes

( i f s hi pped o f fsi te )........................................

5-3 C.

AN ANNUAL

SUMMARY

OF THE RADIATION EXPOSURE RECEIVED BY FACILITY PERSONNEL AND BY VISITORS, IN TERMS OF THE AVERAGE RADIATION EXPOSURE PER INDIVIDUAL AND THE GREATEST EXPOSURE PER INDIVIDUAL FO R E ACH O F TH E TWO G R0VP S..........................................

5-3 D.

AN ANNUAL

SUMMARY

OF THE RADIATION LEVELS AND THE LEVELS OF CONTAMINATION OBSERVED DURING ROUTINE SURVEYS PERFORMED AT THE FACILITY, IN TERMS OF THE AVERAGE AND THE HIGHEST LEVELS............

5-3 E.

THE LOCATION AND MAGNITUDE OF THE MAXIMUM MEASURED OR CALCULATED DIRECT RADIATION LEVEL IN UNRESTRICTED AREAS DUE TO DIRECT RADIATION FROM THE FACILITY, AND DIRECT RADIATION FROM FACILITY EFFLUENTS...........................................................

5-4 1.

The Maximum Direct Radiation Level in Unrestricted Areas Due to Direct Radiation From the Facili ty...........................

5-4 2.

The Maximum Direct Radiation Level in Unrestricted Areas Due to Direct Radia tion From the Facility Effluents.................

5-8 F.

A DESCRIPTION OF THE GENERAL METHODS USED AND AN ANNUAL

SUMMARY

OF THE RESULTS OF ENVIRONMENTAL SURVEYS PERFORMED OUTS I DE THE FAC I L I TY................................................

5-14 1.

The Onsite Environmental Radiation Monitoring Program...........

5-14 2.

The Offsite Environmental Radiation Monitoring Program..........

5-17 3.

An Annual Summary of Onsite and Offsite Environmental Radiation Mon i t o r i n g Re s u l t s..............................................

5-19 a.

Reactor Facility Stack Monitor (0nsite).....................

5-20 b.

Reactor Facility Area Monitoring Composite Dosimeters, Reactor Fence TLDs and Integrating Ionization Chambers, and Di rect Radiation Measurements (0nsi te)..................

5-20

Analysis of Reactor Contributed Radioactivity in Liquid c.

E f f l ue n t s ( 0n s i t e )..........................................

5-21 d.

Soil. Water, and Vegetation Moni toring (0ffsi te)............

5-22 e.

Ai rborne Gamma Moni to ri ng (0f fs i te).........................

5-23 G.

REFERENCES..........................................................

5-26

List of Tables Table Title Page 3.1 OSTR Operating Statistics (Using The FLIP Fuel Core).............

3-13 3.2 OSTR Operating Statistics with the Original (20% Enriched)

S ta nd a rd T R I GA Fu el Co re.........................................

3-14 3.3 Present OSTR Operati ng Sta tis tics................................

3-15 3.4A OSTR Use Time in Terms of Operational Functions..................

3-16 3.4B OSTR Use Time in Terms of Specific Use Categories................

3-17 3.5 OSTR Mul t i pl e U s e Ti me...........................................

3-18 3.6 Use of OSTR Reac to r Expe rimen ts..................................

3-19 3.7 Unpl anned Shu tdowns (Sc rams ).....................................

3-20 4.1 OST R Te a c hi n g Ho u rs..............................................

4-7 4.2 Other Educational Insti tutions Which Utilized the 0STR...........

4-8 4.3 Student Enrollment in Nuclear Engineering and Nuclear Science Courses..........................................................

4-9 4.4 Graduate Student Thesis Research Which Utilized the 0STR.........

4-10 4.5 OSTR Funded Research Hours.......................................

4-11 4.6 Summary of Research Projects Involving the OSTR, and the Fu n d i n g A g e n c i e s.................................................

4-12 4.7 Summary of Visitors to the OSTR, July 1, 1984 throu June 30, 1985......................................gh 4-19 5.1

~ Monthly Summary of Liquid Waste Discharges for the Year July 1,1984 through June 30, 1985...............................

5-27 5.2 Monthly Summary of Gaseous Waste Discharges for the Year July 1,1984 through June 3 0, 19 8 5...............................

5 - 2 8

Table Title Page 5.3 Annual Summary of Solid Waste Discharges for the Year July 1, 1984 through June 3 0, 198 5...............................

5 - 2 9 5.4 Annual Summary of Radiation Exposure Received by Facility Personnel and Visitors for the Year Jul June 30, 1985..........................y 1, 1984 through 5-30 5.5 Annual Summary of Radiation Levels and Contamination Levels Observed Within the Reactor Facility During Routine Radiation Surveys for the Year July 1,1984 through June 3 0, 198 5..........

5-31 5.6 Total Dose Equivalent Recorded on Operating Area Composite Dosimeters Located Inside the TRIGA Reactor Facility for the Year July 1, 1984 through June 30, 1985..........................

5-32 5.7 Total Dose Equivalent at the TRIGA Reactor Area Fence for the Year July 1,1984 through June 30, 1985..........................

5-34 5.8 Annual Average Concentration of the Total Net Beta Radioactivity (Minus 3 ) for Offsite Environmental Soil, Water, and Vegetation H

Samples for the Year July 1, 1984 through June 30, 1985..........

5-35 5.9 Total Dose Equivalent at the Offsite Airborne Gamma Monitoring Stations for the Year July 1, 1984 through June 30, 1985.........

5-38 8

List of Figures Figure Title Page 3.1 Monthly surveillance and Maintenance............................

3-21 3.2 Quarte iy Surveillance and Maintenance..........................

3-22 3.3 Semi.nnual Surveillance and Maintenance........................

3-23 3.4 Annual Surveillance and Maintenance.............................

3-24 3.5 OSTR Annual Energy Production Vs. Time (Fiscal Year)............

3-25 5.1 Operating Area Composite Dosimeter Locations for the TRIGA Reactor Building External Walls.................................

5-39 5.2 Area Radiation Monitor Locations for the TRIGA Reactor, and on the TRIGA Reactor Area Fence.................................

5-40 5.3 Monitoring Stations for the OSU TRIGA Reactor for the Year July 1, 1984 through June 30, 1985..............................

5-41

' ' - ^ -

~-

~

PART 1 INTRODUCTION AND SUPGMRY

1-1 PART 1 INTRODUCTION AND SU W RY A.

INTRODUCTION TO THE OREGON STATE TRIGA REACTOR (OSTR) ANNUAL REPORT The reporting period for this annual report is from July 1, 1984 through June 30, 1985.

Because this report satisfies the requirements of more than one organization, all of the information included may not be of equal concern to all recipients, but a comprehensive table of contents has been included to aid in selecting and locating information of specific interest to the reader.

This report does not include detailed data for the OSTR's original (20% enriched) standard TRIGA fuel core; however, a summary of the important operational statistics for that core's use period (1967-76) is included in Table 3.2.

For more information on the original fuel, the reader is referred to the 1976-77 OSTR annual report, which contains considerably more details on the history of the original (20% enriched) core.

This year's report uses statistics which reflect the operating history of the (70% enriched) FLIP fueled core.

This core has been in use at the OSTR since August of 1976 and remains in ur,e through the present time.

For reporting purposes, the FLIP core has been established as the basis for operational history in all OSTR annual reports beginning with the one issued for the 1976-77 reporting period.

B.

SU N RY OF OSTR USE DURING THE REPORTING PERIOD During the year July 1, 1984 through June 30, 1985:

1.

The OSTR generated 39.4 MWD of energy.

2.

The OSTR consumed 49.5 grams of 235 U 3.

The OSTR was pulsed 72 times.

4.

No fuel elements were added to the core.

1-2 5.

Eighteen academic courses were accommodated, which included seven OSU courses in nuclear engineering, seven OSU courses in chemistry, one OSU course in radiation protection, one OSU thesis project in physics, one OSU thesis project in geology, and one OSU thesis project in ocean-ography. Reactor use time for these programs totaled 81 hours9.375e-4 days <br />0.0225 hours <br />1.339286e-4 weeks <br />3.08205e-5 months <br />.

6.

One person, sponsored by a U.S. Department of Energy Grant administered by the University of Virginia, is being trained in reactor operations.

A total of 14 hours1.62037e-4 days <br />0.00389 hours <br />2.314815e-5 weeks <br />5.327e-6 months <br /> of reactor time was used exclusively for this training.

This time has been listed under teaching because of the nature of the training.

7.

Forty-eight funded research projects (a 23% increase over the previous reportir.g period) and four unfunded research (teaching) projects were accommodated by the reactor.

Reactor use time for funded research programs totaled 713 hours0.00825 days <br />0.198 hours <br />0.00118 weeks <br />2.712965e-4 months <br /> (a 27% increase over the previous reporting period), and totaled 18 hours2.083333e-4 days <br />0.005 hours <br />2.97619e-5 weeks <br />6.849e-6 months <br /> for unfunded research (teaching) projects.

8.

During the reporting period, 769 visitors (a 46% increase over the previous reporting period) viewed the reactor during scheduled tours and other university functions.

Reactor use time for visitor open-house (demonstration) events totaled 11 hours1.273148e-4 days <br />0.00306 hours <br />1.818783e-5 weeks <br />4.1855e-6 months <br />, while the remainder of the visitors viewed the reactor during times when it was being operated for regularly scheduled research and teaching.

9.

The reactor was in use an averege of 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> during a typical 45-hour work week. Hence, the reactor was used approximately 81% of the available time.

C.

SUfMARY OF RADIATION CENTER LABORATORY USE DURING THE REPORTING PERIOD The Radiation Center laboratories provided much support for reactor releted research and teaching, in addition to supporting numerous other academic projects not directly associated with the OSTR.

In the former category, the Center's diversified radiation counting instrumentation accom-modated work ranging from introductory undergraduate counting experiments through sophisticated analysis using gamma spectroscopy.

Likewise, the many laboratory facilities supported a wide range of nuclear and radio-chemical procedures for materials previously irradiated in the reactor.

1-3 Ranking high among the other research and teaching which the Center accomodated, were irradiations using the 300 kVp X-ray facility and ir-radiations using the Cobalt-60 gama irradiator.

Thirty different irradi-ations (a 58% increase over the previous reporting period) were conducted using the Cobalt-60 irradiator, and included such samples as fish eggs and fish cells, wheat seeds, blackberry plants, and other horticultural specimens.

D.

Sup0MRY OF OSTR ENVIRONMENTAL AND RADIATION PROTECTION DATA Year July 1,1984 1.

Liquid Waste Data (See Table 5.1)

Through June 30, 1985 a.

Total estimated quantity of radioactivity released (to the sanitary sewer)(in curies)(1) 6.50 x 10-5 3, 60C0, 152 u b.

Detectable radionuclides in the liquid waste H

E c.

Estimated average concentration of released radioactive material at the point of release (in microcuries per cubic centimeter) 7.26 x 10-6 d.

Percent of applicable MPC for released liquid radioactive material at the point of 0.25%(2) release (%)

0.0075%(3) e.

Total volume of liquid effluent released, including diluent (in gallons)(4) 2366 (1) The OSU operational policy is to subtract only detector background from our water analysis data and not background radioactivity in the Corvallis city water.

(2) Based on values listed in 10 CFR 20, Appendix B, Table 2, Column 2.

(3) Based on values listed in 10 CFR 20, Appendix B. Table 1. Column 2, applicable to sewer disposal.

(4) Total volume of effluent plus diluent does not take into consideration the additional mixing with approximately 95,000 to 115,000 gallons per year of liquids and sewage nonnally discharged by the Radiation Center complex into the same sanitary sewer system.

1-4 Year July 1, 1984 2.

Gaseous Waste Data (See Table 5.2)

Through June 30, 1985 Total estimated quantity of radioactivity a.

released (in curies)ll) 9 41 b.

Detectable radionucifdes in the gaseous waste (2) 41 r (T1/2= 1.83 hr)

A c.

Estimated average atmospheric diluted concentration of argon-41 at the point of release (in microcuries per cubic centimeter) 5.70 x 10-8 d.

Percent of applicable MPC for diluted concentration of argon-41 at the point of release (%)

1.43 Total estimated release of radioactivity e.

in particulate form with half-l greater than 8 days (in curies)jvqs t3; none Year July 1,1984 3.

Solid Waste Data (See Table 5.3)

Through June 30, 1985 Total amount of solid waste a.

disposed of (in cubic feet) packaged and 11.0 b.

Detectable radionuclides in the solid waste 24Na, 6 5Zn,

SICr, 75Se, seCo, 124Sb 59Fe, 140La soCo, 54Mn c.

Total radioactivity in the solid waste (in curies) 9.46 x 10-4 (1) The decrease in the total argon-41 released during the current reporting period is due to several modifications designed to reduce the argon-41 ef fluent to as-low-as-reasonably-achievable levels.

The total argon-41 output for the 1984-85 reporting period is approximately 74.3% of last year's value (a drop of 25.7%).

(2) koutine gamma spectroscopy analysis of the gaseous radioactivity in the stack discharge indicated that it was virtually all argon-41.

(3) Evaluation of the detectable particulate radioactivity in the stack discharge confirmed its origin as naturally occurring radon daughter products, pre-dominantly lead-214 and bismuth-214, which are not associated with reactor ope ra tions,

i

I-5 4.

Radiation Exposure Received by Facility Year July 1,1984 Personnel and Visitors (in mrem)(See Table 5.4)

Through June 30, 1985 Facility operating personnel (mrem) a.

1) Average whole body 64.00
2) Average extremities 111.00
3) Maximum whole body 380.00
4) Maximum extremities 1090.00 b.

Facility research personnel (mrem)

) Average whole body 1.00

23) Average extremities 2.00 Maximum whole body 25.00
4) Maximum extremities 70.00 c.

Visitors (mrem)

1) Average whole body

<1.00

2) Maximum whole body 10.00 5.

_ Number of Area and Offsite Environmental Year July 1,1984 Monitoring Samples Evaluated Through June 30, 1985 a.

Area composite dosimeters inside the TRIGA facility:

1) Beta-gamma-sensitive component in the dosimeter 96
2) Neutron-sensitive component in the dosimeter 32 b.

Vendor (I)- suppl.ed TLD monitors on the reactor facility fence 72 Ost' TLD monitors on the reactor facility fence 108 c.

d.

Readings ' rom integrating ionization chambers on the reactor facility fence 216 pR/hr measurements around the perimeter of e,

the reactor facility fence 108 f.

Offsite environmental soll samples 16 9

Offsite environmental water samples 12 (1)

Radiation Detection Company, Sunnyvale, California, was the vendor.

I-6 5.

Number of Area and Offsite Environmental Year July 1,1984 Monitoring Samples Evaluated (Continued)

Through June 30, 1985 h.

Offsite environmental vegetation samples 56 1.

Offsite vendor (l)-supplied TLD monitors 88 j.

Offsite OSU TLD monitors 231 k.

Readings from offsite integrating ionization chambers 264 1.

pR/hr measurements at the offsite airborne

(

gamma monitoring stations 2 28 (1) Radiation Detection Company, Sunnyvale, California, was the vendor.

l k

PART 2 U

I GENERAL INFORM TION

2-1 PART 2 GENERAL INFORMATION A.

RADIATION CENTER The Oregon State TRIGA Reactor (OSTR) is located in the Radiation Center at Oregon State University.

The Radiation Center was designed and established to:

1.

Accommodate all types of internal and off-campus instructional programs involving nuclear science, nuclear engineering, radiation protection and related areas.

2.

Support research, deve!opment and service programs involving nuclear science and engineering.

3.

Provide a place especially designed for the use and handling of radio-isotopes and other sources of ionizing radiation.

4.

Provide a variety of ionizing radiation sources for fast and thermal neutrons, and X-ray and gamma radiation.

Construction of the Radiation Center was divided into two phases.

The first phase was completed in June of 1964 and consisted of 32,397 square feet of office and laboratory space.

The second phase was completed in March of 1967 and consisted of a nuclear research reactor housed in a 9,956 square foot building adjacent to the existing Radiation Center.

In 1975 temporary space totaling 1,600 square feet was added for interim accommodation of the rapidly expanding nuclear engineering program.

In 1977 additional temporary space equaling another 1,600 square feet was added. The Radiation Center complex at present totals 45,553 square feet.

The Radiation Center currently incorporates a variety of laboratories and equipment.

In particular, these facilities are designed to accommodate:

I.

Instructional programs in nuclear engineering, radiation biology, radiation protection, and nuclear and radiation chemistry.

2.

Instrumental and radiochemical neutron activation analysis.

3.

High-level and low-level radiochemical research.

4.

Neutron radiography and neutron diffraction.

5.

Irradiation experiments involving X-rays, gamma-rays, and neutrons.

2-2 6.

Measurement of various types of ionizing radiation.

7.

Calibration of a wide variety of nuclear instrumentation used in radiation protection.

8.

Bioassay procedures for various radionuclides.

9.

Radioactive waste management, packaging of radioactive materials for transportation and emergency response to accidents involving radionuclides.

10. Consultation in the application of radioisotopes and other radiation research.

11.

Exploratory programs involving the novel uses of radioisotopes and other radiation sources.

B.

FACULTY MEMBERS RESIDING AT THE RADIATION CENTER

  • Smith, Clifford V.,

Jr.

Director, OSU Radiation Center Director, OSU Institute of Nuclear Science and Engineering OSTR Reactor Administrator Head, Department of Nuclear Engineering Anghaie, Samim Assistant Professor of Nuclear Engineering

  • Binney, Stephen E.

Associate Professor of Nuclear Engineering Chairman, OSTR Reactor Operations Committee Daniels, Malcolm Professor of Chemistry

  • Dodd, Brian OSTR Assistant Reactor Administrator Associate Professor of Nuclear Engineering
  • Johnson, Arthur G.

Assistant Director for Radiation Protection and Regulatory Affairs, OSU Radiation Center Senior Health Physicist, OSU Radiation Center Professor of Nuclear Engineering and Radiation Health

  • Loveland, Walter D.

Professor of Chemistry Luo Shyr-Tung Instructor of Nuclear Engineering

  • Reactor users for research and/or teaching.

2-3 Mac Vicar, Robert President Emeritus, OSU

  • Pastorek, Christine Instructor of Chemistry Popovich, Milosh Vice President Emeritus, OSU
  • Ringle, John C.

Professor of Nuclear Engineering Associate Dean of the Graduate School, OSU

  • Robinson, Alan H.

Professor of Nuclear Engineering

  • Schmitt, Roman A.

Professor of Chemistry Sugihara, Thomas T.

Dean of Science, OSU Wang, Chih H.

Professor Emeritus. OSU

  • Woods, W. Kelley Professor of Nuclear Engineering C.

RESEARCH PERS010lEL USING RADIATION CENTER FACILITIES 1.

Post-Doctorate Research Associates Name Field Research Program Director

  • Collier, Robert W.

Oceanography J. Dymond

  • Dudek, Nan Oceanography P. A. Wheeler
  • Hughes, Scott S.

Chemistry R. A. Schmitt

  • LaTouche, Y. D.

General Science D. L. Willis 2.

Scientists and Trainees l

Advisor or Research l

Name Field (Affiliation)

Program Director i

  • Ahmed, Kamal Reactor Operations B. Dodd Training (IAEA, l

Bangladesh Atomic Energy l

Commission)

  • Reactor users for research and/or teaching

2-4 Advisor or Research Name Field (Affiliation)

_ Program Director

  • Alamgir, Mohammad Neutron Activation Analysis R. A. Schmitt (Bangladesh Atomic Energy Commission)

Al Hassan, Layla Nuclear Chemistry M. Daniels (Jeddah Colle e for Girls, Saudi, Arabia

  • Barry, Gene Neutron Activation Analysis R. A. Schmitt (University of Oregon)
  • Brandon, Alan D.

Neutron Activation Analysis R. A. Schmitt (University of Oregon)

  • Brodman, Bruce High Speed Neutron Radiography A. H. Robinson (U.S. Department of Defense)
  • Busamongkol, Reactor Operations (IAEA B. Dodd Yuthapong Fellowship, Thailand)
  • Clingman, William Neutron Activation Analysis R. A. Schmitt (University of Oregon)
  • Collier, Patricia Neutron Activation Analysis R. W. Collier (Oceanography /0SU)
  • Conard, Roberta A.

Neutron Activation Analysis R. W. Collier (Oceanography /0SU)

  • Dawydiak, Crysia Delayed Neutron Counting D. L. Willis (General Science, OSU)
  • Espenan, Gregory Neutron Activation Analysis R. A. Schmitt (Louisiana State University)
  • Fritz, Raimund High Speed Neutron Radiography A. H. Robinson j

(Federal Republic of Germany)

Gallagher, Jennifer Autoradiography C. H. Wang (Vet. Medicine /OSU)

  • Geist, Dennis Neutron Activation Analysis R. A. Schmitt (University of Oregon) l i

i Reactor users-for research and/or teachina l

2-5 Advisor or Research Name Field (Affiliation)

Program Directo_r

  • Goles, Gordon tieutron Activation Analysis R. A. Schmitt (University of Oregon)

Golightly, Vivian Autoradiography C. H. Wang (Chemistry /0SU)

  • Haines, Sara Neutron Activation Analysis R. A. Schmitt (University of Oregon)
  • Hu, Ziuzhen Neutron Activation Analysis R. A. Schmitt (People's Republic of China)
  • Knaus, Ronald Neutron Activation Analysis R. A. Schmitt (Louisiana State University)
  • Laul, J. C.

Neutron Activation Analysis R. A. Schmitt (Battelle Pacific Northwest Lab.)

Liu, Xueyu Radiation Biology C. H. Wang (Jiangsu Academy of Agricultural Science, People's Republic of China)

  • Murali, Ahobila Neutron Activation Analysis R. A. Schmitt Vajjula (NASA /JSC Houston)
  • Pham, Cecilia Reactor Operator Trainee-B. Dodd
  • Radosevich, Stephan Neutron Activation Analysis R. A. Schmitt (University of Oregon)
  • Redecker, Klaus H.

High Speed Neutron Radiography A. H. Robinson (Federal Republic of Gennany)

  • Reich, David Neutron Activation Analysis R. A. Schmitt (University of Oregon)
  • Ritchie, Beatrice Neutron Activation Analysis R. A. Schmitt (University of Oregon)
  • Schmitt, Joe Neutron Activation Analysis R. A. Schmitt (Battelle Pacific Northwest Lab.)
  • Smith, Monty Neutron Activation Analysis R. A. Schmitt (Battelle Pacific Northwest Lab.)
  • Reactor users for research and/or teaching.

2-6 Advisor or Research Name Field (Affiliation)

Program Director

  • Sonnenthal, Eric Neutron Activation Analysis R. A. Schmitt (University of Oregon)
  • Taffet. Michael Neutron Activation Analysis R. A. Sch'iitt (University cf Oregon)
  • Ungerer, Carl Neutron Activation Analysis J. Suess (Oceanography /0SU)
  • Vincenzi, Ed Neutron Activation Analysis R. A. Schmitt (University of Oregon)
  • Vogel, Allan Neutron Activation Analysis R. A. Schmitt (Portland State University)

Wang, Guoli Neutron Activation Analysis R. A. Schmitt (People's Republic of China)

Wang, Zhifen Neutron Activation Analysis R. A. Schmitt (People's Republic of China) 3.

Graduate Students Degree Name Program Field Advisor

  • Anellis, Lawrence MS Rad Health A. G. Johnson Bostick, Kent MS Nuclear Engr S. E. Binney Bukar, Kyari A.

MS Nuclear Engr S. E. Binney Butler, Hugh PhD Crop Science A. P. Appleby

  • Carter, Stephen MS Geology R. D. Lawrence
  • Casey, Coreen PhD Chemistry W. D. Loveland Cheng, Beato PhD Nuclear Engr S. E. Binney
  • Chidester, Stephen MS Nuclear Engr A. H. Robinson Cho, Byung-0H MS Nuclear Engr A. H. Robinson
  • Coe, Douglas H.

MS Nuclear Engr A. H. Robinson

  • Greek, Kevin MS Nuclear Engr A. H. Robinson Ha, Jae-Joo MS Nuclear Engr S. Anghaie
  • Harris, Richard MS Nuclear Engr S. E. Binney Humphries, Larry MS Nuclear Engr B. Dodd Johnson, Susan MS Nuclear Engr S. E. Binney Kaya, Sadi MS Nuclear Engr S. Anghafe
  • Reactor users for research and/or teaching

2-7 Name Program Field Advisor

  • Keizer, Philip MS Rad i;aalth D. L. Willis Lee, Chungchan PhD Nuclear Engr A. H. Robinson Lopez, Ricardo PhD Nuclear Engr S. E. Binney Luo, Shyr-tung PhD Nuclear Engr S. E. Binney
  • Newell, Daniel MS Nuclear Engr A. H. Robinson
  • Pyle, Douglas MS Geology J. Dasch Saamin, Shaharudin PhD Horticulture M. Thompson Salahuddin, Kamran MS Nuclear Engr J. C. Ringle Saleh, Hassan PhD Nuclear Engr S. E. Binney Samuels, Jeffrey PhD Nuclear Engr S. Anghaie Savidge, William MS Bio. Ocean D. A. Carey Sui, Yueh-Chun MS Nuclear Engr A. H. Robinson
  • Tenbrook, Warren MS General Sci S. E. Binney
  • Verplanck, Philip MS Geology R. A. Schmitt
  • Von Breymann, Marta PhD Oceanography R. W. Collier
  • Walker, Robert PhD Geology R. A. Schmitt
  • Walsh, Ian MS Oceanography J. Dymond Yilmaz, Tamer PhD Nuclear Engr S. Anghaie Youssefnia, Mohammad PhD Nuclear Engr J. C. Ringle D.

CLASSIFIED STAFF AT THE RADIATION CENTER Name Title Anderson, Terrance V.

Reactor Supervisor Busby, Harold L.

Scientific Instrument Technician Campbell, Ken Custodian (through April 30,1985)

Campbell, Shirley C.

Accounting Clerk I Conrady, Michael R.

Chemist Cramer, Dana L.

Secretary Cunningham, Patricia A.

Clerical Assistant Flickinger, Evelyn C.

Administrative Assistant Hall, Arthur D.

Custodian Johnson, Dean E.

Research Assistant Latham, Jennie Clerical Assistant Liedtke, James D.

Research Assistant Moeller, Wanda M.

Clerical Specialist Neyhart, Shirley N.

Business Manager Pratt, David S.

Radiation Specialist Woodrow, Doyle K.

Scientific Instrument Technician CReactor users for research and/or teaching.

m-

i 2-8 E.

REACTOROPERATIONSSTyF_

Title Name Reactor Administrator C. V. Smith, Jr.

Assistant Director, Radiation A. G. Johnson Center, and Principal Security Officer Assistant Reactor Administrator B. Dodd Reactor Supervisor T. V. Anderson Senior Reactor Operators T. V. Anderson S. E. Binney B. Dodd Reactor Operator W. T. Carpenter Senior Health Physicist A. G. Johnson Radiation Specialist D. S. Pratt Radiation Protection Student ' orkers Lane, Vincent T.

J Lewis, Bryan R.

Nelson, Lindsay A.

Pauley, Keith A.

Persinger, Richard W.

Scarbrough, Allen L.

F.

REACTOR OPERATIONS COMITTEE Name Affiliation S. E. Binney, Chai rman Nuclear Engineering T. V. Anderson Radiation Center B. Dodd Radiation Center and Nuclear Engineering A. G. Johnson Radiation Center and Nuclear Engineering J. C. Ringle Nuclear Engineering and Graduate School A. H. Robinson Nuclear Engineering i

R. A. Schmitt Chemistry l

S. A. Stone School of Engineering, Dean's Office i

D. L. Willis General Science (Radiation Biology &

Radiation Health) l l

[

r

2-9 6.

RADIATION SAFETY C0petITTEE Name Affiliation S.E. Binney Nuclear Engineering A.G. Johnson Radiation Center and Nuclear Engineering N.I. Kerkv11et Veterinary Medicine G.E. Little Radiation Safety Officer R.G. Senechal Geology (CurrentChairman)

H.W. Shaup Biochemistry R. Morita Microbiology T. Beasley Oceanography - Marine Science Center G. Beaudreau Agricultural Chemistry

,,-w

1 PART 3 OSTR OPERATIONAL DATA i

3-1 PART 3 i

OSTR OPERATIONAL DATA i

A.

BRIEF CHRONOLOGY OF THE OSTR OPERATING HISTORY 1.

The OSTR has operated for 18 years.

2.

From March of 1967 to August 1969 the maximum reactor power level was restricted to 250 kW.

3.

In August 1969 the reactor was licensed to operate at a maximum reactor power level of 1 MW.

From that date until June of 1971 the OSTR could operate at 1 MW for short periods of time only, due to the lack of sufficient cooling capacity.

1 4.

In June of 1971 the cooling capacity was upgraded to allow continuous operation at 1 MW.

5.

In July of 1976 the reactor was shut down for one month while a new FLIP fuel core (70% enriched fuel) was installed.(1)(2)(3)

This year's annual report will not attempt to review in detail the OSTR's operation over the past 18 years.

Only the operating statistics for the FLIP fueled core will be presented in detail since we have established the (70% enriched) FLIP fuel as the basis for operational history for this and subsequent annual reports. More detailed information concerning the original (20% enriched) standard fuel core can be obtained from the 1976-77 OSTR annual report, dated August 31, 1977.

(1) See Table 3.1 for a tabular review of the OSTR's operating statistics with the FLIP core.

(2) See Table 3.2 for a summary of the OSTR's operating statistics with the original (20% enriched) standard TRIGA fuel core.

(3) See Figure 3.5 for a graphic review of the OSTR's energy production with the FLIP core.

3-2 8.

OPERATING STATISTICS The utilization of the OSTR for the current reporting period showed a very slight increase (s0.2%) in the total number of operating hours when compared to the previous reporting period (see Table 3.1).

The thermal energy generated in the reactor during the reporting period was 39.4 MWD. The cumulative thermal energy generated by the FLIP core now totals 275 MWD from August 1,1976 through June 30, 1985. Reactor use time averaged approximately 81% of the normal nine-hour, five-day week schedule. See Table 3.1 and Tables 3.3 through 3.5 for operating statistics applicable to this reporting period.

Excess reactivity showed an increase (s30() during the current reporting period, which is mainly due to the rate of consumption of the burnable poison in the fuel.

This is consistent with' the fuel manufacturer's prediction that the FLIP fuel should initially decrease in reactivity until about 200 MWD, after which time it should begin a net gain in reactivity due to depletion of the burnable poison.

It is expected that the OSTR with its burnup of 275 MWD will continue to show an increase in excess reactivity during the coming years.

The excess reactivity is predicted to peak after about 4.5 MW years.

C.

EXPERIENTS PERFORED At the present time there are 12 approved reactor experiments on the active list which can be utilized in reactor related programs.

These experiments are listed below:

NOTE: Missing numbers identify reactor experiments which are in the inactive file and are not currently being used.

A-1 Reactor Operation in Any of its Modes With No Sample Irradiation.

B-3 Irradiation of Materials in Assorted Matrices for Elements H to Bi Inclusive, Plus Natural Th and U, for Neutron Activation Analysis.

B-8 Isotope Production for Elements 1 Through 83 (H to Bi) Excluding Cd.

.. ~.

3-3 B-11 Nuclear Reaction Studies Using the Irradiation of Stable Elements to Produce Any Nuclide Fonned During the Neutron Irradiation of Natural Uranium.

B-12 Exploratory Experiments to Investigate the TRIGA's Capability to Achieve Certain Experimental Goals.

(If the TRIGA can achieve the desired goals, a regular experiment is established.)

B-21 Advanced Neutron Radiography Using Beam Port #3.

(Radiography of all conventional items plus ordinance materials.)

B-23 Measurement of Neutron and Gamma Fluxes in the Thermal Column for Nuclear Engineering Laboratory Classes.

B-24 General Neutron Radiography Using Beam Port #1.

(Ordinance items are excluded from radiography in this experiment.)

B-25 Measurement of Relative Neutron Fluxes in the Reactor Core and Experimental Facilities Using Fission Probes and Self-Powered Detectors.

B-29 Fuel Element Reactivity Worth Measurements.

B-30 Irradiation of Jet Diesel, and Furnace Fuels.

(Irradiation of various fuel oils for neutron activation analysis.)

B-31 Detennination of Neutron Fluxes in the OSTR Core and Irradiation Facilities, Using Various Activation Foils or Wires.

Of the 12 currently approved experiments, six were used during the reporting period. A tabulation of infonnation relating to reactor experiment use is given in Table 3.6, and includes a listing of the experiments which were used, how often each was used, and the general purpose of the use.

Presently, 25 additional experiments are in the inactive file and could be reapproved for use as needed.

D.

UNPUUINED SHUTD0lelS There were no unplanned shutdowns (scrams) during the current reporting period. Table 3.7 will contain a tabulation of unplanned shutdowns when they occur.

3-4 E.

CHANGES TO THE FACILITY, TO FACILITY PROCEDURES, AND TO REACTOR EXPERIMENTS PURSUANT TO 10 CFR 50.59 1.

Introduction The information contained in this section of the report provides a summary of OSTR changes made during the reporting period under the provisions of 10 CFR 50.59. As applicable, changes have been grouped into three categories:

those dealing with the facility itself; those dealing with the facility's procedures; and those involving OSTR experiments.

For each change identified, a brief description of the change and a summary of the safety evaluation is included.

The infonnation presented in this section is also submitted annually to the USNRC in a separate report in order to meet the requirements of 10 CFR 50.59(b).

2.

10 CFR 50.59 Changes to the Facility There were three changes to the facility itself which were reviewed and perfonned under the provisions of 10 CFR 50.59 during the reporting period. A summary of each change and 1ts safety evaluation follows.

a.

Installation of an Annunciator on the Ventilation Fan for the Argon Ventilation System Description The ventilation system for the OSTR's experimental facilities (e.g., the rotating rack, the beam ports, the thennal column, etc.) is commonly called the argon ventilation system. This system is equipped with a fan to enhance air flow through the various experimental facilities, and ultimately the system discharges its ventilation air into the intake plenum for the main reactor building ventilation fan. Although the fan for the argon ventilation system definitely creates a higher air flow through the system when it is operating, the negative pressure in the main reactor building fan intake plenum (relative to the argon ventilation system) induces a reasonable air flow through the argon ventilation system without the argon fan operating.

3-5 Operation of the ventilation fan for the argon ventilation system is indicated by an "on" light on a control panel located on the west wall of the reactor control room.

However, this indicator light is not in a conspicuous location and is difficult to see from the reactor console.

Because of this situation, it was considered unlikely that the reactor operator would be immediately alerted if the argon ventilation system fan stopped.

As a result of the above, the OSTR operations staff recommended the installation of a visible and audible annunci-ator for the argon vent fan circuit which would immediately alert the reactor operator in the event that the fan stopped l

operating.

Safety Evaluation The installation of an annunciator on the argon vent system fan enhances safety and provides needed notification in the event the fan malfunctions.

However, failure of the vent fan poses no safety problem, as an acceptable air flow through the argon ventilation system is still maintained due to the pressure-induced flow mentioned previously. Ai r flow through the system is also an optional matter controlled by the reactor operations staff using flow regulating valves installed as part of the original reactor equipment and upgraded and supplemented within the last 2 years under the provisions of 10 CFR 50.59.

The above facility change was reviewed by a Reactor Operations Staff Subcommittee and approved by the Reactor Operations Committee (ROC) prior to being made.

It was concluded that this facility change did not require a change in the Technical Specifications, or constitute an unreviewed safety question as defined in 10 CFR 50.59(a)(2).

3-6 b.

Electronic Timing Device For Measuring Control Rod Drop Times Description During an NRC inspection of the OSTR in March of 1985, the NRC representative suggested that consideration be given to an alternative method for measuring the drop times for the reactor control rods. At that time, the semiannual measurements of control rod drop times were being performed manually with a stop watch.

NOTE: The stop watch method has been very adequate considering the two-second drop time limit in the OSTR Technical Specifications.

i In an effort to respond to the NRC's suggestion, the OSTR staff investigated possible ways of implementing an electronic timing device for the control rod drop time measurements.

The results of the study demonstrated that the control rod drop time could be measured electronically using a commercially available counter-timer, a relay, and a five-position selector switch. The process utilized existing but non-used contacts

1) the control rod drive foot switches, and 2) the console on:

CONT /0N switches. The CONT /0N switch starts the timer at the instant the control rod starts to drop, and the foot switch stops the timer when the rod reaches the bottom.

The selector switch determines which control rod drop time is being measured.

Safety Evaluation This addition does not compromise safety or affect any control circuitry. Spare contacts were used on existing control rod microswitches to make the rod drop measurements possible. The rod drop measurement apparatus is passive and responds to switch actuation only, and will not have an effect on the control rod drive circuits, even if the apparatus should malfunction.

i l

3-7 The above addition was reviewed by a Reactor Operations Staff Subcomittee and approved by the ROC prior to being made.

It was concluded that the addition did not require a change in the Technical Specifications or constitute an unreviewed safety question as defined in 10 CFR 50.59(a)(2).

c.

Change in the Display Locations for Data from the Instrumented Fuel Element Themocouples Description The display locations for fuel temperature data from the instrumented fuel element themocouples (TCs) were changed so that the TCs measuring the maximum and minimum fuel temperature now display their readings on the more accurate OMEGA digital instrument, and the middle TC displays its reading on the analog meter in the left-hand console drawer.

Safety Evaluation There are no adverse safety implications associated with this change. All of the TCs are routinely calibrated and were recalibrated after this change.

It is known that the newer 0MEGA digital instrumentation is more accurate, and therefore it increases safety to have the maximum and minimum fuel temperatures displayed on this new digital meter.

(Note: Only one TC reading is actually required by the Technical Specifications. )

The above change was reviewed by a Reactor Operations Staff Subcommittee and approved by the ROC prior to being made.

It was concluded that this change did not require a change in the Technical Specifications or constitute an unreviewed safety question as defined in 10 CFR 50.59(a)(2).

3.

10 CFR 50.59 Changes to Facility Procedures There was one 10 CFR 50.59 change to facility procedures made during the reporting period. A description of this change follows.

3-8 a.

Revisions to the OSTR and Radiation Center Emergency Response Plan Description Following an action drill and a number of training sessions held during the week of July 16-20, 1984, it was recognized that there were a number of minor corrections required to the Emergency Plan. These changes are listed below:

Change No.

Page Change 1

Cover page Change revision date to July 24, 1984 2

2-2 Add definition of ERIP 3

2-3 Retyped to include text carried over from page 2-2.

No revision of content.

4 3-4 Change Student Health Service to Student Health Center.

This is necessary due to a name change.

5 3-5 Change Student Health Service to Student Health Center.

This is necessary due~to a name change.

6 3-6 Correct the spelling of responsi-bilities 7

3-6 Reverse the order of the first two people in the line of succession for the Emergency Director.

This order is more consistent with personnel responsibilities.

8 3-8 Correct the spelling of responsi-biitties in two places on this page.

9 3-11 Change Radiation Center Clerical Specialist to Radiation Center Clerical Assistant. The original job title was in error.

10 7-1 Change OSU Student Health. Service to Center

l 3-9 Change No.

Page Change 11 7-2 Change Trojan nuclear plant to Trojan Nuclear Plant 12 7-3 Add an 's' to air sampler 13 7-8 Change shutdown to shut down 14 7-14 Change shutdown to shut down 15 8-5 Revise paragraph b) completely to allow for the new 911 Emergency Dispatch system now in use in the Corvallis area 16 8-6 Change Student Health Service to Center 17 8-7 Change Student Health Service to Center Safety Evaluation Most of the changes are typographical and English corrections and therefore do not have any safety implications.

One change reverses the order of two people who may fill the Emergency Director position.

The new sequence is more consistent with personnel responsibilities and will enhance safety.

The latter is true because the Assistant Director will now only ' fill the position of Senior Health Physicist, enabling him to concentrate on the radiological safety aspects of the emergency. Another change is required because, since the plan was written, the Corvallis area has instigated a 911 emergency dispatch system. This also enhances safety because there are now less telephone nurabers to call if there is need for assistance.

The above changes were reviewed by a Reactor Operations Staff Subcommittee and approved by the ROC prior to being made.

It was concluded that these changes did not require a change in the Technical Specifications or constitute an unreviewed safety question as defined in 10 CFR 50.59(a)(2).

4.

10 CFR 50.59 Changes to Reactor Experiments There was one 10 CFR 50.59 change to a reactor experiment during this reporting period. A description of this change follows.

3-10 a.

Change to Experiment B-24-Revised to Add Subpart B-24F Description A change to experiment B-24-Revised was made which added Subpart B-24F and thereby enabled zone plate encoded neutron holography to be perfonned in beamport #1.

The experiment change provided for the radiography of small (less than 3.0 cm3) objects and was designed so that only neutrons scattered approximately 90 degrees (toward the access plug for the beam port shield) would be recorded by the film.

The new subpart B-24F will allow the imaging of neutrons which are scattered from any cbject currently allowed to be radio-graphed by experiment B-24-Revised.

Before imaging on the film, the scattered neutrons will pass through a gadolinium or cadmium encoding aperture which will encode target spatial infonnation on the film. The film cassette will be placed at a 90* angle to the beam axis and will be surrounded by a lead " igloo" which will enclose the cassette except for one small imaging aperture which allows scattered neutrons to reach the film, and for one entire face (the surface facing the access plug) which allows the cassette to be removed easily. The cassette will be attached to a support that extends from the access plug, allowing it to be rolled into and out of the beam port with the access plug.

A barrier of aluminum, wood, and masonite will be placed above the lead igloo and will serve the personnel access barrier function usually provided by an aluminum plate connected to the end of the access plug's carriage. This carriage necessarily will be removed during this experiment. A cadmium sheet on the beam side of the igloo will help to reduce interfering neutron radiation.

When it is necessary to change the target and/or coding aperture during experimentation, all requirements of Experiment B-24-Revised will be met before entering the beam port blockhouse. This includes shutdown of the reactor and full coordination with health physics personnnel.

3-11 No modifications to the beam port #1 facility as stated above affect any existing shielding or alter any approved operating procedures, or reduce any safety margins now in use. All procedures, safety requirements, and facility descriptions of B-24-Revised, excluding the specific (not applicable) procedures and requirements for Sub-parts A through E, will apply to this experiment.

Safety Evaluation None of the new experimental apparatus will be in the direct beam and so from a safety viewpoint this experiment is very similar to standard neutron radiography experiments.

Other very minor modifications to the facility will provide radiation protection features which are equivalent to those for other approved neutron radiography experiments.

The above experiment change to B-24-Revised was reviewed by a Reactor Operations Staff Subcommittee and approved by the ROC prior to being made.

It was concluded that the change did not require a change in the Technical Specifications or constitute an unreviewed safety question as defined in 10 CFR 50.59(a)(2).

4 5.

Forthcoming Changes to Be Made Under 10 CFR 50.59 At some point in the future we expect to replace the rotating specimen rack in the TRIGA reactor under the provisions of 10 CFR 50.59.

F.

SURVEILLANCE AND MAINTENANCE 1.

Non-Routine Maintenance 15 AUG 84 The "Agastat" delay timer, which initiates the stack monitor filter failure alarm, was replaced.

~

24 AUG 84 The scram relay designated K-1 was replaced.

5 SEP 84 The rectifier in the control rod magnet circuit was replaced 21 NOV 84 New evacuation horn batteries were installed.

13 DEC 84 The calibration potentiometers on the stack monitor gas and particulate channels were replaced.

3-12 21 JAN 85 The primary coolant pump bearing was replaced.

25 JAN 85 A replacement blower motor was installed in the reactor top continuous air monitor and the old motor repaired.

27 MAR 85 Area Radiation Monitor #11 was repaired.

3 APR 85 A new DOWN switch for the regulating control rod was installed.

5 APR 85 A new UP switch for the shim control rod was installed.

24 APR 85 A new motor for cooling tower for #1 was installed.

~21 JUN 85 The argon ventilation system fan was repaired.

2.

Routine Surveillance and Maintenance The OSTR has a routine surveillance and maintenance (S&M) program.

Examples of typical S&M lists are presented in Figures 3.1 through 3.4.

Those items marke1 with an asterisk (*) are required by the OSTR Technical Specifications.

1 G.

REPORTABLE OCCURRENCES There was one reportable occurrence during the reporting period.

This involved an indication that the OSTR might have experienced a very small fuel cladding leak.

In keeping with the requirements of the OSTR Technical Specifications, a written report of the event was sent to the Region 5 Office of the USNRC.

The existence of the initially suspected fuel cladding leak has not to this date been established despite extensive efforts to confirm its presence or absence. An additional surveillance program designed to detect any changes in the current situation has been added to the OSTR's operational routine.

i Table 3.1 OSTR Operating Statistics (Using the FLIP Fuel Core)

Opermtional Date 1 AUG 76 1 JUL 77 I JUL 78 1 JUL 79 1 JUL 80 1 JUL 81 1 JUL 82 1 JUL 83 1 JUL 84 for through through through through through through through through.

through FLIP Core 30 JUN 77(1) 30 JUN 78 30 JUN 79 30 JUN 80 30 JUN 81 30 JUN 82 30 JUN 83 30 JUN 84 30 JUN 85 urs 875 819 458 875 1255 1192 1095 1205(2) 1208 g

Megawatt Hours 451 4%

255 571 1005 999 931 943(2) 946 Megawatt Days 19 20.6 10.6 23.8 41.9 41.6 38.8 39.3 39.4 Grams 235U Used 24 25.9 13.4 29.8 52.5 52.4 48.6 49.3 49.5 Hours at Full 401 481 218 552 998 973 890 929(2) 904 Power (IM)

Number of Fuel 85 0

2 0

0 1

0 0

0 Elements Added to Core Number of Irradt-443 375 329 372 348 408 3%

469 407 ation stequests (1) Reactor shutdown Ju'y 26, 1976 for one month in order to completely refuel the reactor with a new FLIP fuel core.

(2) These values have been changed in this report to correct errors detected in the 1983-84 report. All subsequent reports will show these new values.

t 4

C

.._m

_~

i l

i i

l l

Table 3.2' t

OSTR Operating Statistics with the Original (205 Enrieb d) Standard TRIGA Fuel Core I

Operational Data 8 MR 67 1 JUL 68 1 JUL 69 1 APR 70 1 APR 71 1 APR 72 1 APR 73 1 APR 74 1 APR 75 1 APR 76 TOTAL: MR 67

~

' for 20s Enriched through through through-through through through through through through through through JUL 76 Core 30 JUN 68 30 JUN 69 31 M R 70 31 MR 71 31 M R 72 31 MR 73 31 MR 74 31 MR 75 31 M R 76 26 JUL 76 (1)

(2)

(3)

. Operating Hours (4)

(critical) 904 610 567 855 598 954 705 563 794 353 6903 5

Meagawatt brs 117.24 102.47 138.05 223.77 195.11 497.82 335.94 321.45 408 213 2553 Megawatt Days 4.88 4.27 5.75 9.3 8.1 20.74 13.99 13.39 17 9

106.4 Grams 2350 Used 6.13 5.36 7.21 11.7 10.2 26.031 17.57 16.81 21.35 10.7 133 Hours at Full Power (250 KW) 429 369 58 856 Hours at Full Power (1 m) 20 23 100 401 200 291 460 205 1700 j

Number of Fuel Elements Added 70 2

13 1

1 1

2 2

2 0

1560 to Core (Initial)

Number of Irrad-lation Requests 429 433 391 528 347 550 452 396 357 217 4100 Neuber of Pulses 202 236

299, 102 98 249 109 183 43 39 1560 (1) Reactor Went critical on March 8. 1967 (70 element core; 250 m).

(3) Reactor shutdown June 1.1971 for one month for cooling system Note: This period leggth is 1.33 years as initial criticality upgradtr:g.

(2) Reactor shutdown August 22, 1969 for one month for upgrading to (4) Reactor shutdown July 26, 1976 for one month for refueling 1 #Gi (did not upgrade cooling system). Note: This period length reactor with a new full FLIP fuel core. Note: This period is only 0.75 years as there was a change in the reporting period length is 0.33 years.

from July-June to April-March.

Y E

D t

f,-pr. w..,-

.c v -.wwe F P v-- t.

--'t-'

=~'a

3-15 Table 3.3 Present OSTR Operating Statistics e

Annual Values Cumulative Values for for Operational Data 1 JUL 84 1 AUG 76 for through through FLIP Core 30 JUN 85 30 JUN 85 j

1.

MWH of energy produced 946 6597 2.

MWD of energy produced 39.4 275 3.

Grams 235U used 49.5 345.40 4.

Number of fuel elements added to core 0

85 + 3 FFCR(1) 5.

Number of pulses 72 1004 6.

Hours-reactor critical 1208 8982 7.

Hours at full power (1 MW) 904 6346 8.

Number of startup and shutdown checks 253 2255 9.

Number of irradiatjog reouests processedt2p 407 3547

10. Number of samples irradiated 4583 43996 (1) Fuel Follower Control Rod.

(2) Each irradiation request could authorize from 1 to 120 samples.

The number of samples per irradiation request averaged approximately 11 during the current reporting period.

3-16 Table 3.4A 4

OSTR Use Time in Terms of Operational Functions Annual Values Cumulative Values for for i

OSTR Operational Function 1.JUL 84 1 AUG 76 through through 30 JUN 85 30 JUN 85 (hours)

(hours) 1 1.

Checkout, core excess and shutdown 380 3284 1

2.

Load and unload samples 59 766 4

4 3.

Reactor in operation (l) 1467

.10817 4.

Total reactor use time 1906 14867 (1)

Includes preclude time.

(Preclude time is the time the reactor is not available for use due to performance of surveillance and maintenance items, such as fuel element inspections, transient rod lubrication, control rod calibration, power calibration, etc.)

3 i

l l

I 4

h i

e,,

+ - -

,n--

3-17 Table 3.4B OSTR Use Time in Terms of Specific Use Categories Annual Values Cumulative Values for for OSTR Use Category 1 JUL 84 1 AUG 76 through through 30 JUN 85 30 JUN 85 (hours)

(hours)

Teaching (d trpental 1.

and others)999r(2 ui 1

95 1653 2.

OSU Research(1)(3) 477 4073 3.

Off-campus research(1)(3) 236 953 4.

Forensic services (l) 0 101(4) 5.

Reactor preclude time 614 5214 6.

Facility time (5) 473 2723 7.

Visitor demonstration (6) 11 150 8.

Total reactor use time 1906 14867 (1)

Includes sample loading and unloading.

(2) See Tables 4.1 and 4.2 for teaching statistics.

(3) See Table 4.5 for research statistics (4) Prior to the 1981-1982 reporting period, forensic services were grouped under another use category.

Since then and for subsequent reports, it will be a separate category and the cumulative hours will be compiled beginning with the 1981-1982 report.

(5) The time OSTR spent operating to meet NRC facility license requirements.

Whenever possible, beneficial uses of the reactor were made, including irradiation of items requiring long irradiation times.

(6) Reactor use time for visitor open-house (demonstration) events was 11 hours1.273148e-4 days <br />0.00306 hours <br />1.818783e-5 weeks <br />4.1855e-6 months <br />.

The remainder of the visitors viewed the reactor during times when the reactor was being operated for regularly scheduled research and teaching.

3 - 18 Table 3.5 OSTR Multiple Use Time (l)

Annual Values Cumulative Values for for Number of Users 1 JUL 84 1 AUG 76 through through 30 JUN 85 30 JUN 85 (hours)

(hours) 4 1.

Two users 75 653 2.

Three users 26 89 3.'

Four users 7

12 4.

Total multiple use time 108(2) 754(3)

(1) Multiple use time is that time when two or more irradiation requests are being concurrently fulfilled by operation of the reactor.

(2) Represents 9% of the total hours the reactor was critical during this reporting period.

(3) Represents 8% of the total hours the reactor was critical since startup l

with FLIP fuel in August of 1976.

l

..-...__m Table 3.6 Use of OSTR Reactor Experiments (l)

)

Research Teaching Reactor Experiment) ~

Funded Other Unfundod Scheduled Unscheduled Facility TOTAL' Numbert2 Thesis Scholarly Thesis Classes Classes Use Work Research Work A-l' 0

.0 0

13 8

138 159 B-3 6

115 5

12 0

0 138 i

B-8 7

4 28 18 0

0 58 B-12 3

0 0

0 0

0 3

B-21 16 19 1

0 0

0 36 B-24 11 2

0 0

0 0

13 TOTAL 43 140 34 43 8

138 407 (1) This table displays the number of times each fonnal reactor experiment was used for a particular purpose.

(2) The following tabulation gives the reactor experiment number and its corresponding title:

4 A-1 Nonnal TRIGA Operation B-3 Neutron Activation Analysis B-8 Isotope Production i

B-12 Exploratory Experiments Y

B-21 Beam Port #3 Advanced Neutron Radiography G

B-24 Beam Port #1' Neutron Radiography y-

-7 w

rw

. _ - 3,.

t l 20 Table 3.7

{

Unplanned Shutdowns (Scrams) l Type of Scram Number of Occurrences Cause of Scram i

None during this reportin9 0

Not Applicable period 4

1 4

4 L

..N i

i 1

i 4

4 i

i J

t i.

l 4

r

.,- -..~..

.cijulU a.1 Monthly Surveillance and Mainhnance (Sample Form) 0STR0P 13 SURVEILLANCE & MAINTENANCE FOR MONTH OF SURVEILLANCE & MAINTENANCE TO BE PERFORMED LIMITS AS FOUND REMARKS & INITIALS COM TED MAXIMtM

  • 1 FUNCTIONA'. CHECK OF REACTOR WATER LEVEL ALARMS MOVEMENT t3 INCHES M

2 MEASUREMENT OF THE REACTOR PRIMARY WATER pH h

3 MEASUREMENT OF THE BULK SHIELD TANK WATER pH

  • [l.5
  • LIQUID:1 1" DN S.G. DISCS UP 4

EMERGENCY POWER SYSTEM BATTERY CHECKS aS 250 INVERTER

  • GENERATORA y

g 7T)RR: NONE LIQUID: FULL 5

EVACUATION HORN & P.A. EMERGENCY SYSTEM S.G.

>l.250 BATTERY CHECKS VOLTS 12VDC CORR NDNE l

6 INSPECTION OF THE BRUSHES ON THE PNEtNATIC CHANGE WHEN TRANSFER SYSTEM BLOWER MOTOR 1/4" LEFT 7

FUNCTIONAL CHECK OF EVACUATION ALARM ALL WORKING 8

This a.

tion in not cw'rvn t ly unad.

9 AVERAGE MONTHLY PRIMARY WATER CONDUCTIVITY 4 HICROMHOS/CM 10 GREEN LIGHT BULB REPLACEMENT HAX: 75 WATT 11 CHANGE LAZY SUSAN FILTER l

12 LUBRICATE THE TRIGA TUBE LOADING TOOL (REEL)

USE GUN OIL 13 REACTOR TOP CAM O!L LEVEL CHECK OSTROP 13.13 l

14 PROPANE TANK LIQUID LEVEL CHECK (% FULL)

>50%

2 15 ARM SYSTEM L.E.D. TESTS:

  1. 8
  1. 1 BEAM PORT 10 s100 mR/hr 2

l

  1. 9 FUEL STORAGE PIT 10 a100 mR/hr 2
  1. 10
  1. 3 BEAM PORT 10 s100 mR/hr 2
  1. 11 RX BAY TABLE 10 s 100 mR/hr 2
  1. 12 TOP OF RX 10 a 100 mR/hr 2
  1. 13 DEMINERALIZER ROOM 10 a150 mR/hr 2
  1. 14 RABBIT ROOM 10 s 9') mR/hr y

U

  • Techninal Specifications Requirement nevised c/S3

Quartarly Survnillance and Maintenanca (Sample Ferm)

~

-.. 0STR0P 14 SURVEILLANCE a MAINTENANCE FOR THE QUARTER OF

/

/

19

~

SURVEILLANCE & MAINTENANCE TO BE PERFORMED LIMITS AS FOUND DUE DATE CONTED REMARKS & INITIALS

  • 1 REACTOR OPERATIONS COMITTEE (ROC) AUDIT OF REACTOR QUARTERLY OPERATIONS FOR

/

/

QUARTER s

  • 2 QUARTERLY ROC MEETING QUARTERLY
  • 3 FUEL ELEMENT ftADIATION LEVEL MEASUREMENTS IN WATER y,2 N ATE 4

INSPECTION OF THE SOLEN 0ID VALVES IN THE PNELMATICFUNCTIONAL TRANSFER SYSTEM 5

PNEUMATIC TRANSFER SYSTEM INSERTION TIME CHECK s 6 SECONDS I

l 6

ROTATING RACK CHECK FOR UNKNOWN SAMPLES QUARTERLY i

7 FUNCTIONAL CHECK OF EMERGENCY LIGHTS FUNCTIONAL 8

WESTRONIC RECORDER SLIDE WIRE CLEANING QUARTERLY PART: 500 V i M 9

STACK MONITOR CHECKS (OIL DRIVE MOTORS H.V. SOURCE)

GAS: 900 V 250 10 TRACERLAB AREA RADIATION MONITOR (ARM) VOLTAGE 25 V SUPPLYi101 CHECKS H.V. 560 V *10%

l 11 ARM SYSTEM ALARM CHECKS CHAN 1

2 3

4 5

6 7

8' 9 10 11 12 13 14

=

AUD FUNCTIONAL LIGHT PANEL ANN 12 OPERATOR QUARTERLY CHECK DA NSE NAME DATE CHECKED p

QUARTERLY 13 CHECK FILTER TAPE SPEED ON STACK MONITOR 1"/HR t 0.2 Y

14 INCORPORATE 0!B & FCB INTO DOCUMENTATION QUARTERLY OSTROP 9.0 15 TRANSIENT R00 CALIBRATION p,pf,,d f/85

  • Technical Specifications Requirement

Semi-Annual Surveillance and Maint: nance (Sample Fonn) 0STR0P 15 SEMI-ANNUAL SURVEILLANCE & MAINTENANCE FOR SURVEILLANCE & MAINTENANCE TO BE PERFORMED LIMITS AS FOUND DUE DATE REMARKS & INITIALS CO TED

  • 1 FUNCTIONAL a) SOURCE INTERLOCK SETTING 22 cos a

0F fH b) SIMULTANEOUS WITHDRAWAL OF 2 RODS 1 only b

g INTERLOCKS c) PULSE INITIATION ABOVE 1 kW 51 kW e

$5 b d

I d) PULSE INTERLOCK ON RANGE SWITCH e) TRANSIENT ROD CYLINDER AIR INTERLOCK i5IN

(

e f) PULSE MODE ROD MOVEMENT INTERLOCK NO MOVE f

g) PREVENTS PULSING AB0VE $2.55 o INSERTION 5$2.55 q

  • 2 SAFETY a) PERCENT CHANNEL 5110%

a UITS b) SAFETY SCRAM 5110%

b c) PERIOD SCRAM 23 sec c

  • 3 CONTROL R00 TRANS SAFE SHIM REG hfE j

a) ROD DROP

<2 sec 4

SCRAM TIMES b) WITIORAWAL

$50 sec h

c) INSERTION

$50 sec c

  • 4 PULSE COMPARISON (PREVIOUS PULSE:

MW,

'C) 520%

+5 REACTOR BAY VENTILATION SYSTEM SHUT DOWN TEST hTROP

+6 CALIBRATION OF THE FUEL ELEMENT TEMPERATURE CHANNEL 2*C t

  • 7 MATERIALS BALANCE REPORT N
  • 8 CLEANING & LUBRICATION OF TRANSIENT R0D CARRIER INTERNAL BARREL ggy O L 9

LUBRICATION OF BALL-NUT DRIVE ON TRANSIENT R0D CARRIER GUN O L 10 LUBRICATION OF THE ROTATING RACK BEARINGS 10 W OIL P

11 CONSOLE CHECK LIST (OSTROP 15-11) 12 CONSTANT AIR MONITOR RECORDER MAINTENANCE 13 WESTRONICS RECORDER ZERO & CALIBRATION CHECKS 14 STANDARD CONTROL R00 MOTOR CHECKS 15 FLUKE FUEL TEMPERATURE INSTRUMENT "D" CELL CHANGE w

  • Technical Specification Requirements '

Revised 4/85 b

w

w Annual Surveillance and Maintenanca (Sample Form) 0STR0P 16 ANNUAL SURVEILLANCE & MAINTENANCE FOR THE YEAR SURVEILLANCE & MAINTENANCE TO BE PERFORMED LIMITS AS FOUND DUE DATE REMARKS & INITIALS CO TED OSTROP

  • 1 BI-ANNUAL INSPECTION OF ALL CONTROL RODS 12.0 ANNUAL REPORT (DUE JUNE 30 + 75 DAYS)

SEPT 13 0 GP

  • 3 STANDARD CONTROL R00 CALIBRATION O OP

'4 REACTOR POWER CALIBRATION OP

  • 5 CALIBRATION OF REACTOR TANK WATER TEMPERATURE METERS

'6 CONSTANT AIR MONITOR CAllBRATION P

  • 7 STACK MONITOR:

a) CALIBRATE PARTICULATE MONITOR l

b) CALIBRATE GAS MONITOR N

26 P

  • B AREA RADIATION MONITOR CAllBRATION P
  • 9 WATER MONITOR CAllBRATION 210 REACTOR OPERATOR REQUALIFICATION PROGRAM OP 11 SNM PHYSICAL INVENTORY.

12 EMERGENCY RESPONSE PLAN DRILL 13 STANDARD CONTROL R00 DRIVE INSPECTION 14 SECURITY GUARD RETRAINING 15 50.59 REPORT SEPT b

16 INTRUSION ALARM RESPONSE DRILL (C.P.D. & OSU SECURITY)

ROP 17 EMERGENCY POWER INVERTER TEST O

18 REPLACE P.A. & EVAC SYSTEM LEAD-ACID BATTERIES f$

Y

  • Technical Spec 1fIcation Requirements.

p,pg,,j gfgg

3-25 Figure 3.5 OSTR Annual Energy Production Vs. Time (Fiscal Year) 40 1976-77:

19.0 MWD 1977-78: 20.6 MWD 1978-79:

10.6 MWD 1979-80:

23.8 MWD 1983-81:

41.9 MWD 35 1981-82:

41.6 MWD 1982-83: 38.8 MWD 1983-84: 39.3 MWD 1984-85:

39.4 MWD 30 - -

25 20 15 10 5

i i

i i

i l

I i

0 76-77 77-78 78-79 79-80 80-81 81-82 82-83 83-84 84-85 FISCAL YEAR

4 9

1 PART 4 OSTR UTILIZATION DATA L

J

..m

. ~, _.. _

4-1 PART 4 OSTR UTILIZATION DATA A.

TEACHING PROGRAMS THAT UTILIZED THE OSTR The OSTR accommodated 18 OSU academic courses and one special Radiation Center Reactor Operator Training Program. These programs utilized 95 hours0.0011 days <br />0.0264 hours <br />1.570767e-4 weeks <br />3.61475e-5 months <br /> of reactor time.

The academic courses are listed below:

Oregon State University Academic Courses NE 101 Nuclear Engineering Orientation NE 102 Nuclear Engineering Orientation NE 203 Nuclear Radiation Detection and Measurement NE 406 Projects (Nuclear Engineering)

NE 441 Nuclear Reactor Experiments NE 461 Radiation Protection Engineering NE 503 Thesis (Nuclear Engineering)

CH 107 General Chemistry Laboratory CH 206H General Chemistry Honors CH 207 General Chemistry Laboratory CH 316 Nuclear Reactor Chemistry CH 419 Radioactive Tracer Methods CH 505 Reading and Conference CH 528 Activation Analysis GS 405A/-

505A Field Practices in Radiation Protection G 503 Thesis (Geology)

OC 503 Thesis (Oceanography)

PH 503 Thesis (Physics)

Oregon State University Special Classes One person sponsored by a U.S. Department of Energy grant administered by the University of Virginia. participated in a special research reactor operator training program conducted at the Radiation Center.

This training program is one of five in the U.S. for disadvantaged I

citizens, particularly minorities and females.

The trainee has completed about 50% of the two year program, and will be taking the NRC reactor operator examination in September of 1985.

1

4-2 Part of the special reactor operator training program required exclusive use of the reactor. This time is reflected in Table 4.1 under the heading of "Special Classes." Most of the training program has been integrated into the regular operating schedule ard, therefore, the special class hours do not represent the total training time but only that used exclusively for training purposes.

Additional data regarding the use of the OSTR for teaching and academic programs are shown in Tables 4.1 through 4.4.

B.

RESEARCH PROJECTS THAT UTILIZED THE USTR During the reporting period, there were forty-eight funded research projects which utilized 713 hours0.00825 days <br />0.198 hours <br />0.00118 weeks <br />2.712965e-4 months <br /> of reactor time, and four unfunded research (teaching) projects which utilized 18 teaching hours of reactor time (see Table 4.1, footnote 1 and Table 4.5).

Of these research projects, twenty-eight were conducted by Oregon State University, fifteen by the University of Oregon, three by Lousiana State University, one by Portland State University, one by Western Washington University, and four by Battelle Pacific Northwest Laboratories (under DOE prime contract number DE-AC06-76RLO-1830) in Richland, Washington.

Table 4.5 gives statistics regarding OSTR-funded research hours, and Table 4.6 gives a summary of the different research projects.

C.

PUBLICATIONS RESULTING FROM RESEARCH USING THE OSTR 1.

Publications in Print Bogard, D.D., G.J. Taylor, X. Keil, M.R. Smith and R.A. Schmitt

" Impact melting of the Cachari eucrite 3 Gy ago."

Geochim.

Cosmochim. Acta, 49, 1985, 941-946.

Bogard, D., R.A. Schmitt, M.R. Smith and M. Rhodes (1984) " Petrology and shock age of the Palo Blanco Creek eucrite" Meteoritics 19, 219-220.

Budahn, J. R., and R. A. Schmitt, "Petrogenetic Modeling of Hawaiian Tholeiitic Basalts: A Geochemical Approach," Geochim. Cosmochim.

Acta, M, 1985, 67-88.

4-3 Davidson, G.R., G.P. Lahti, J.D. Ingle, Jr., J.C. Westall, C.W.

Bennett, E.I. Jolma, and D.M. Mcdonald, " Post Accident Systems for Monitoring of Primary Coolant for Fission Products, Boron, pH, and Chloride," EPRI Report NP-3513,1984.

Dickinson, T., G.J. Taylor, K. Keil, R.A. Schmitt, S.S. Hughes and M.R. Smith " Apollo 14 Aluminous Mare Basalts and Their Possible Relationship to KREEP."

J. Geophys.

Res., 90, 1985 C365-C374.

Hughes, S.S. and R.A. Schmitt "Whole-rock INAA Elemental Abundances and REE Variations in EH4, EH5 and EL6 Chondrites. Lunar and Planetary Science XVI, 1985, 372-373.

Hughes, S.S. and R.A. Schmitt "Zr/Hf Ratios in Lunar Mare Basalt Groups--Interim Report #2.

Lunar and Planetary Science XVI, 1985, 374-375.

Laul, J.C., M.R. Smith, J.J. Papike and S.B. Simon " Agglutinates as Recorders of Regolith Evolution: Application of the Apollo 17 Drill Core." Proceedings of the 15th Lunar and Planetary Science Conference, M, 1984, 161-170.

Laul, J.C., R.J. Walker, C.K. Shearer, J.J. Papike and S.B. Simon,

" Chemical Migration by Contact Metamorphism Between Pegmatite / Country Rocks: Natural Analogs for Radionuclide Migration." Scientific Basis for Radioactive Waste Management VII, Material Research Proceedings, 26, 1984, 951-958.

Laul, J.C., M.R. Smith, S.B. Simon and J.J. Papike, " Chemistry and Petrology of Apollo 12 Drive Tube 12027." Proceedings of the 15th Lunar and Planetary Science Conference, H,1985, 507-516.

Laul, J.C., C.K. Shearer, J.J. Papike, " Chemistry of Potassium Feldspars from Three Zoned Pegmatites, Black Hills, South Dakota:

Implications Concerning Pegmatite Evolution." Geochim.

Cosmochim Acta, M, 1985, 663-673.

Laul, J.C., T.D. Swindle, M.W. Caffee, C.M. Hohenberg, G.B. Hudson, S.B. Simon and J.J. Papike, " Noble Gas Organization in Apollo 14 Regolith Breccia 14318:

1291 and 244 u Regolith Chronology,"

P Proceedings of the 15th Lunar and Planetary Sciences Conference, 9_0, 1985, 517-540.

0 Laul, J.C., C.K. Shearer, J.J. Papike,' S.B. Simon and R. Christian,

" Pegmatite / Wall Rock Interactions, Black Hills, South Dakota:

Progressive Boron Metasomatism Adjacent to the Tip Top Pegmatite."

Geochim. Cosmochim Acta, 48, 1984, 2563-2580.

Laul, J.C., M.R. Smith, M.-S. Ma, T. Huston, R.M. Verkouteren, M.E. Lipschutz and R.A. Schmitt, "Petrogenesis of the SNC (Shergottites, Nakhalites, Chassignites) Meteorites; Implications for Their Origin From a Large Dynamic Planet, Possibly Mars."

Proceedings of the 14th Lunar and Planetary Science Conference, 1984, 612-630.

4-4 Laul, J.C., J.W. Shervais, L. A. Taylor and M.R. Smith, " Pristine Highland Clasts in Consortium Breccia 14305: Petrology and Geochemistry." Proceedings of the 15th Lunar and Planetary Science Conference, 81, 1984, 25-40.

Laul, J.C., N. Hubbard, R.W. Perkins, "The Use of Natural Radionuclides to Predict the Behavior of Radwaste Radionuclides in Far-Field Aquifers." Scientific Basis for Radioactive Waste Management VII, Material Research Society Proceedings, 26, 1984, 891-897.

2. Theses Espenan, G.D., " Determination of Aluminum in Fish Tissue by Instru-mental Neutron Activation Analysis." Master's Thesis, Louisiana State University, 1985.

Gastill, D. Kurt, "Peturbed Angular Correlation Measurements of Hyperfine Fields in Liquid and Amorphous Selenium-Tellurium Alloys." Ph.D. Thesis, OSU, 1984.

Greek, K.J., " Optimum Temporal and Contrast Consideration in Extremely High Speed Motion Neutron Radiography." Master's Thesis, Nuclear Engineering, OSU,1985.

Newell, D., "Real Time Neutron Radiography." Master's Thesis, Nuclear Engineering, OSU,1985.

3.

Reports Submitted for Publication l

Dickinson, T., K. Keil, L. Lapaz, D.D. Bogard, R. A. Schmitt, M.R.

Smith and J.M. Rhodes, " Petrology and shock age of the Palo Blanco Creek Eucrite." Chemie der Erde, 1985.

Hughes, S.S.,

R. A. Schmitt, Y.L. Wang and G.J. Wasserburg, Trace Element Characteristics and Sr-Nd Isotopic Constraints on the Magmatic Sources of Serra Geral Continental Flood Basalts, Southern Brazil." Contributions to Mineralogy and Petrology.

(submitted).

Jaeger, H., J. A. Gardner, J.C. Haygarth and P.L. Rasera, " Structural Characterization of Zirconia Ceramics by Perturbed Angular Correlation Spectroscopy." Submitted to J. American Ceramic Society.

Robinson, A.H., "High Speed Radiography of Solid Caseless Ammunition."

Submitted to U.S. Army,1985.

4-5 D.

PRESENTATIONS AT PROFESSIONAL MEETINGS nCULTING FROM RESEARCH USING THE OSTR AND FROM OSTR OPERATIONS Davidson, G.R., G.P. Lahti, J.D. Ingle, Jr., J.C. Westall, and M.D.

Naughton, " Post Accident Systems for Monitoring Primary Coolant Radioactivity and Chemistry." Trans. Am. Nucl. Soc.,,4_6, 1984 329.

Fukuoka, T., J. C. Laul, M.R. Smith, S.S. Hughes and R. A. Schmitt,

" Chemistry of Yamato-791197 Meteorite: Evidence for Lunar Highland Origin." Proceedings of Tenth Symposium on Antartic Meteorites (2 page abstract),1985.

Gardner, J.A., H. Jaeger, J. C. Haygarth, and R.L. Rasera, " Microscopic Structure and Phase Transformation of Zirconia-Based Ceramics Determined by PAC." American Ceramic Soc. Bulletin, August 1984,

p. 991, paper presented at the 1984 Pacific Coast meeting of American Ceramic Society.

Jaeger.

H., J.A. Gardner, J.C. Haygarth, and R.L. Rasera, " PAC Investigation of Oxygen-Defect Dynamics in Zirconia-Yttria." Bull. Am. Phys.

Soc. 30., 319 (1985), paper presented at the 1985 March meeting of the American Physical Society.

Jaeger, H., J.A. Gardner, J. C. Haygarth, and R.L. Rasera, " PAC Investigation of Oxygen-Defect Dynamics in Zirconia-Yttria," American Ceramic Society Bulletin, March 1985, p. 464.

Paper presented at the 1985 Annual Meeting of the American Ceramic Society.

Laul, J.C., " Rare Earth Elements Behavior in the Development of Energy Resources." Proceedings of the Fifth International Conference on Nuclear Methods in Environmental and Energy Research, CONF-840408, 425-437, 1985.

Schmitt, R.A., "The Relevance of Lunar Meteorites to Planetary Science" Suess Symposium (Dec 13-14, oral presentation at Univ. Calif.,

San Diego), 1984.

Willis, D.L., and Y.D. LaTouche, "Biokinetic Studies of Natural Uranium in Rats Following Oral Administration of Drinking Water." Oral w'

report during the International Workshop on Gastrointestinal Absorption of Actinides and other Metals at Seattle, Washington, June 24, 1985.

E.

PUBLIC RELATIONS The continued interest of the general public in the TRIGA reactor is evident by the number of people who have toured the facility.

In addition to many unscheduled visitors, and interested individuals who stopped in without appointments because they were in the vicinity,

4-6 a total of 769 people (a 45% increase over the previous reporting period) were given pre-planned and scheduled tours during this reporting pe ri od. See Table 4.7 for statistics on scheduled visitors.

F.

PLANNED CHANGES IN OSTR UTILIZATION A one-shift operation (45 hours5.208333e-4 days <br />0.0125 hours <br />7.440476e-5 weeks <br />1.71225e-5 months <br /> per week) is the current OSTR utilization schedule. At the present time there are no planned changes to this mode of reactor utilization.

4-7 4

Table 4.1 OSTR Teaching Hours 1

Annual Cumulative Values for Values for Description.

1 JUL 84 1 AUG 76 through through 30 JUN 85 30 JUN 85 (hours)

(hours) i Departmental (l) 81 1463 f

Chemistry 25 Nuclear Engineering 38 Geology 8

Oceanography 8

Special Classes (2) 14 190 Total Teaching Time (3,4,5) 95 1653 (1) Approximately 22% of the departmental use hours (18 hours2.083333e-4 days <br />0.005 hours <br />2.97619e-5 weeks <br />6.849e-6 months <br />) was used for unfunded thesis and research work, which we consider to be. teaching.

(2) Six special training classes were conducted for the Reactor Operator Training program.

(3) Includes sample loading and unloading (4) See Table 4.3 for classes and student enrollment.

(5) See Table 3.48.

4 i

f

.-,._...___x,__rm,,.

-_~v y

s

__-.s

.---7

4-8 Table 4.2 Other Educational Institutions Which Utilized the OSTR(1)

Number of Number of Number of Faculty Students Visits to Institution Involved Involved Facility Southern Oregon College 1

5 2

University of Oregon 6

8 2

Portland State University 1

1 2

Western Washington University 1

0 1

Louisiana State University 1

1 1

(1) Does not count community college, high school, and elementary school classes which came through for special tours.

These are listed under the section on "Public Relations."

4-9 Table 4.3 Student Enrollment in Nuclear Engineering and Nuclear Science Courses Number of Students Fall Winter Spring Course Credit Course Title 1984 1985 1985 Nuclear Engineering Courses

  • NE 101 2

Nuclear Engineering Orientation 29

  • NE 102 2-Nuclear Engineering Orientation 20 NE 103 3

Intro. Nuclear Engineering & Comp.

13 NE 201 3

Nuclear Energy Fundamentals 37 NE 202 3

Nuclear Radiation & Matter 28

  • NE 203 3

Nuclear Radiation Detection & Measurement 22 NE 405 1-15 Reading & Conference

  • NE 406 1-15 Projects 5

2 2

NE 407 1-Semina r 17 NE 415 4

Principles Radiation Safety 26 NE 417 4

Principles Radiation Safety 14 NE 419 4

Principles Radiation Safety 14 NE 421 3

Nuclear Reactor Analysis & Computation 26 NE 422 3.

Nuclear Reactor Analysis & Computation 21 NE 423 3

Nuclear Reactor Analysis & Computation 10 NE 430 3

Nuclear Fuel Cycle 16 NE 431 3

Reactor Thermal Hydraulics 22 NE 432 2

Reactor Design 14 NE 433 3

Reactor Design 4

NE 435 2

Nuclear Materials 13 "NE 441

-3 Nuclear Reactor Experiments 14

  • NE 461 3

Radiation Protection Engineering 22 NE 465 3

Nuclear Rules & Regulations 17 f.E 501 1-15 Resea rch 1

  • NE 503 1 15 Thesis 14 11 11 NE 505 1-15 Reading & Conference 4

1 1

NE 505A 1-15 R&C/ Neutron Transport 2

1

  • NE 5058 1-15 RAC/ Reactor Safety 1

NE 506 1-15 Projects 1

NE 507 1 15 Semina r 3

NE 511 2

Neutron Transport Theory 6

NE 512 2

Neutron Transport Theory NE 522 3

Reactor Environmental Problems 9

NE 523 2

Advanced Reactor Design 5

NE $24 3

Advanced Reactor Design 5

NE 531 3

Nuclear Reactor Kin.

B NE 541 3

Advanced Nuclear Fuel Cycle 3

NE 542 3

Advanced Thermal Hydraulics 2

NE 552 3

Cosetational Methods for Nuclear Reactors 10 NE 553 3

Computational Methods for Nuclear Reactors NE 581 3

ST/ Waste Management & Decomissioning 8

NE 583 3

Advanced Nuclear Weste Management 3

Chemistry Courses

  • CH 107 2

General Chemistry Lab 70

  • CH 206 H 2

General Chemistry Honors

  • CH 207 2 ' General Chemistry Lab 4
  • CH 316 4

Nuclear Chemistry 28

    • CH 419 4

Radioactive Tracer Methods 7

  • CH 505 1 15 Reading & Conference (Chemistry)
  • CH 528 4

Activation Analysis 7

Other Courses

    • G 503 1-15 Thesis (Geology) 1 1
    • GS 405A/

2-3. Field Practices in Radiation Detection 1

1 505A

    • PH 503 1-5 Thesis (physics)'
    • 0C 503 1-15 Thesis (Oceanography) 1 1
  • 0STR used occasionally for demonstration experiments
    • 0STR used heavily

Tabla 4.4 Graduate Student Thesis Research Which Utilized the OSTR Student's Name Program Academic Department Faculty Advisor Thesis Topic LOUSIANA STATE UNIVERSITY Espenen. G.

MS Nuclear Science Knaus Aluminum Concentration in Fish Gills OREGON STATE UNIVERSITY Coe D.H.

MS Nuclear Engineering Robinson Neutron Holography Greek, K.

MS Nuclear Engineering Robinson High Speed Neutron Radiography Harris, R.

MS Nuclear Engineering Binney Modeling of Gaasna Pulse Height Distributtons Hoover. A.

MS Geology Snee Idaho Batholiths Jaeger. H.

PhD Physics Ga rdner Petrubed Angular Correlations of Decay Gansnas Xefzer P.J.

MS General Science { Rad. H)

Willis Pharmacokinetics of Natural Uranium in Drinking Water Newell. D.

MS Nuclear Engineering Robinson Real Time Neutron Radiography Verplanck. P.L.

MS Geology Snee Pegmatite Geocheelstry Von Breymann. M.

PhD Oceanography Suess Mg/Nh4 Exchange PORTLAND STATE UNIVERSITY Vogel. A.H.

PhD 8tology Petersen Oregon Lake Sediments UNIVERSITY OF OREGON Brandon.

A.

MS Geology Goles Petrogenesis of Bear Creek Lavas Connelly. T.

PhD Geology / Anthropology Aikens Archaeological Horizon Markers Desonte. D.L.

MS Geology McBirney Geochemistry of the San Esteban Suite I

Geist. D.

PhD Geology Mc81rney Geology of San Cristobal Radosevich. S.

PhD Anthropology Lukacs/Dumond Trace Elements in Ancient Bones Ritchte. B.

MS Geology McBirney Geology of the Western Cascades f

Sonnenthal. E.L.

MS Geology Goles Pegnatoid Crystallfration in Basalts of North-Central l

Oregon Vicenzt. E.

MS Geology Mc8frney Geology and Geocheef stry of Marclena Island. Galapagas

4-11 Table 4.5 OSTR Funded Research Hours Annual Cumulative Values Values for for Types of Research 1 JUL 84 1 AUG 76 through through 30 JUN 85 30 JUN 85 (hours)

(hours)

OSU Research(1) 477 4073 Off-Campus Research(1) 236 953 Total Research(1) 713(2)(3)(4) 5026 (1) Includes sample loading and unloading time.

(2) 18% (130 hours0.0015 days <br />0.0361 hours <br />2.149471e-4 weeks <br />4.9465e-5 months <br />) of the total research hours were funded thesis research.

(3) Research hours, OSU funded:

249 (4) Research hours, others funded:

464

Table 4.6 Suunnery of Research Projects Involving the OSTR. and the Funding Agencies Listing Name of Person (s)

Department and Project Title Description Funding Agency thster Using Reector Institution 1

R. A. Schmitt Chemistry. OSU Tantalum /Ilmenites &

INAA For Ruttles and Ilmenites US Bureau of Mines Rutiles From Worldwide Locations.

S. Mughes

v. Golightly (These Minerals are Used in Ta Productions P. Verplanck as Well as Other Metals) 2 R. A. Schmitt Geology Pegnatite Geochemistry INAA for Trace Elements in Radiation Center. OSU P. Verplanck 05U Certain Geologic Samples to (Unfunded Research)

Determine Source Rock Signature L. W. Snee 3

R. A. Sclunitt Chemistry. OSU Lunar and Meteor 1 tic Chemical and Petrological NASA S. Hughes Actl*;ation Analysis Characterfration of Rock Clasts in Brecciated Meteorites 4

R. A. Schmitt Geology. OSU 16.% Batholiths INAA for Trace Element (REE)

Sigma XI to Investigate Source Rock A. Hoover Affinities. Crustal Contamination L. W. Snee and Mixing Relationships of Plutons of Idaho Batholith 5.

R. A. Schmitt Radiation Center. OSU INAA of Trace Elements Study Major and Minor Trace Radiation Center. OSU S. S. Hughes in Deep Sea Drilling Elements in Sedimentry Rock Riuzhen Hu Projects Samples Obtained in 1000 Meters Below Sea Floor at Site 530A. DSDP 6

R. A. Schmitt Radiation Center. OSU Seat Conductor Analysis INAA Determination of Mg Union Carbide Concentrations in Seat Conductor it. Conrady Samples 7

R. A. Schmitt Physics. OSU Metal Purities INAA of Purified and Unpurified Physics Samples of Te & Se for Na Content R. Walker M. Conrady

?

G

= _..

Table 4.6 (continued)

Listing.

Name of Person (s)

Department and Project Title Dese.iption Funding Agenct Num6er Institution 8'

R. A. Schmitt Radiation Center. 05U Ash Peak Rhyolites INAA of Rhyolitic Volcanics Cheelstry. 050 M. Conrady and Andesttic Volcanics to R. Walker

' Determine Possible Genetic Relationship to $n. m. Ag Mineralization 9

R. A. Schmitt Cheelstry. OSU Miscellaneous On-going Investigation NASA S. Hughes Geological Material of Various Geological Materials to Coincide with Extra Terrestrial Studies

't 10 R. A. Schmitt Radiation Center. OSU Exxon Sediments INAA of Ocean Sediments EXXON M. Conrady to Determine Barium Deposited During Drt111ng Operations i

11 R

A. Schmitt Battelle N.W. Lab Manganese Nodules Study of the Meteoritic BNWL J. C. Laul Fingerprints (That May Have Caused A. V. Murali the Extinction of Dinosaurs) In S. Hughes Manganese Nodule Layers 12 R. A. Schmitt Radiation Center. OSU La & Cr Analysis INAA of Mineral Samples for U.S. Bureau of Mines M. Conrady La and Cr 13 R. A. Schmitt Geology. Western Geology & Petrology INAA of Basaltic & Dacitic USDOE

5. Carter Washington University of Fifes Peak Formation Dike & Lava Flow Rocks
5. Hughes (Central Washington) 14 A. H. Robinson Nuclear Engineering.

Neutron Radiography High Speed Neutron Radiography USD00 K. Greek OSU Of Brief Events (s2 M1111see.onds)

D. New1?

15 A. H. Robinso.

Nuclear Engineering.

Neutron Holography Formation of Psuedo Holograms Radiation Center. OSU D. H. Coe OSU Using Scattered Neutrons From an Irradiated Target Passing i

Through a Coded Aperture

?

~

a i

I Table 4.6 (continued)

Listing Name of Person (s)

Department and Project Title Description Funding Agency Nusher Uslag Reactor institution j

f l

16 A. H. Robinson Nuclear Engineering.

Real-Time Neutron Modification of High Speed Nuclear Engineering, D. Newell OSU Radiography N.R. by Replacing a Ifman OSU l

Camera with a Vfdeo Camera For Real Time Events 17

5. E. Ofaney Muclear Engineering.

U-Tn Analysis of Solid Saaples Radiation Center. 05U

n. R. Conrady OSU For u & Th as a Pilot Project for Future Research C. W. Rennett 18 U. D. Loveland Chemistry. 05U Log P leassurement Measurement of M-Octanol / Water USDOE Partition Coefficient for C. Casey Selected Metal Chelates 19
5. E. Binney Nuclear Engineering.

U-Th INAA of Selected Solid Saagles Radiation Center. 050 M. Conrady 05U for U & Th (Pilot Project) 20

5. E. Binney Nuclear Engineering.

Modeling of Garena Study of Modeling Gassna Pulse Radiation Center.' 05U R. Harris 05U Pulse Height Distri-Height Distributions to Calculate (Unfunded Research) bution the Feasibility of Monitoring Key Nuclides as Indicators of Fuel Element Damage 21 D. L. W1111s General Science. OSU Urantum in Drinking Activation of Rat Blood Kidney.

USEPA D. LaTouche Water Liver in Freeze Dry Form, i

l D. Bergman Followed by Delayed Neutron Counting. to Determine Uranium Concentrations in Tissues (Rat Drinking Water Spiked with Uranium) j l

22 D. L. Willis General Science. OSU U Concentration in Study of the Feasibility of General Science. 05U D. Bergnen Selected Metal Detecting Uranium in Scrapings i

A. G. Johnson Scrapings From a Metal Pipe l

23 R. Collier Oceanography. 05U JDF Characterization of Particle NSF Flux in the Juan De Fuca J. Dymond Hydrotherinal Vent Area

?

l

'i:

-- =.

--~ -

Table 4.6 (continued)

Listing Name of Person (s)

Department and Project Title Description Funding Agency Number Using Reactor Institution 24 R. Collier Oceanography, OSU BETTIS INAA For Trace Elements of Sandia J. Dymond Sediment Trap Samples R. Conard 25 R. Collier Oceawgraphy, OSU Mg/Nh4 Exchange Investigatica of the Role of Radiation Center. OSU A. Ungerer Organic Matter During the (Unfunded Research)

M. Von 8reymann Formation of Marine Dolmites.

This Experiment Examines the Amonium Exchangeable Mg As-sociated with Humic Materials 26 R. Collier Oceanography, OSU MANOP Analysis of Sediment Trap NSF J. Dymond Samples to Determine Fluxes R. Conard of Elements to the Ocean Floor in Mid-Pacific Ocean.

27 T. Seasley Oceanography, OSU Marine Transuranic Study of Fate of Transurante USDOE j

D. McCullough Research and Other Long-Lived Radionucifdes Chi-An Huh in Columbia River Estuary and N.E. Pacific Ocean J

28 R. Buhler Agricultural Chemistry, Dimethylsulfone Explore Possibility of Using Radiation Center OSU R. Reed OSU Metabolism Reactcr to Prepare Na25 (Unfunded Research)

For Mammalian Metabolism Experiment i

29 K. Krane Physics, OSU Perturbed Angular Study Structure of Hf Compounds Physics Dept., OSU J

J. Gardner Correlation istHf Using Perturbed Angular (Wah Chang Grant)

H. Jaeger Perturbation Method l

30 J. C. Laul Battelle Pacific I,unar Chemical INAA for Chemical Study of DOE Prime Contract Northwest Lab.

Characterization Lunar and Meteorite Samples DE-AC06-76-RLO-1830, and Some Terrestrial Rock Special Agreement Separates B-73282-A-U 31 J. C. Laul Battelle Pacific Geological Samples Study of Chemical Migration of DOE Prime Contract t

Northwest Lab.

Various Elements in Geological DE-AC06-76-RLO-1830 Matrices Surrounding Nuclear Special Agreement Waste 8-73282-A-U a

i

Tab 124.6(con Table 4.6 'contfrued)

U sting Name of Person (s)

Department and Project Title Description Funding Agency Number Using Reactor Institution 32 J. C. Laul Battelle Pacific 011 Shale Analysis of Hg. As. Se in USDOE Prime Contract E. Lepel Northwest Lab.

Sagles Obtained From 011 DE-AC06-76-RLO-1830 Shale Retort Process Special Agreement B-73282-A U 33 J. C. Laul Battelle Pacific Polyethylene Determine Trace Elements USDOE Prime Contract E. Lepel Northwest Lab.

in Polyethylene DE-AC06-76-RLO-1830.

Special Agreement 8-73282-A-U 34 J. Lyngdal Tektronix Glass Analysis Characterization of Glass Tektronix M. Conrady Material Lab.

35 R. Petersen Biology. PSU Oregon Lake Sediments Measurement of the Distribution U5 DOE A. H. Vogel of 12 Physiological Important Metals in Lake Sediments 36 R. Knaus Nuclear Science. LSU Aluminum in Fish Gills Determination of Aluminum USDOE G. Espenan Concentrations in Gills of Fish Killed by Aluminum 37 R. Knaus Nuclear Science. LSU Insect Migration Characterization of Different USDOE Races of Moths 1

38 R. Knaus Nuclear Science. LSU A Cretion Study of A Study in Marking Marsh-Mud USDOE The Gulf Marsh Horizons with Rare Earths j

Equivalent to Soil Horizon Markers 39 G. Goles Anthropology U of 0 Trace Elements A Study of Trace Elements in U500E R. A. Schmitt in Ancient Bones Human Bone to Determine Diet

5. Radosevich Proportions in Ancient Populations J. R. Lukacs of People From South Asia D. E. Dumond i

E

Table 4.6 (continued)

Listing homeofperson(s)

Department and Project Title Description Funding Agency Auster Usfag Geoctor Institution 40 G. Geles Geology. U of 0 Trace Elements in INAA of Oregon Coast Intrusive U500E R. A. Schmitt Coast Range Intrusive Rock Samples From Cougar D. Arfch Rocks Mountain. Table Mountain.

Blodget Peak, and Cannibal Mountain 41 G. Geles Geology U of 0 A INemodynamic &

INAA of Selected Rocks to 0500E R. A. Schaftt Petrologic Study Determine REE Yields Which E. L. Sonnenthat in the Picture Gorge Will Be Used to Model Processes Basalt of North-Central That May Have Occurred During Oregon Cooltag of These Flows 42 E. Goles Geology / Anthropology.

Archaeological Analysts of Pumice Collected From U500E R. A. Schaftt U of 0 Nortron Merkers From Two Archaeological stes in a

T. Connelly Western Oregon to Establish Tentative Identiffcation as Merama C. M. Aftens Tephra 43 G. Geies Geology. U of 0 Bear Creek laves INAA Determination of the U500E R. A. Schmitt Petrogenests of Laves in The l

A. Brandon Bear Creek Drafnage in Central Oregon 44 G. Goles Geology. U of 0 Geochemical Features A Study to Reconstruct the USDCC R. A. Schmitt of The San Esteban Suite History of the Isla San Esteban A. R. McGirney and its Relationship to the D. L. Desente Tectonic Development of the Northern Gulf of California 45 G. Goles Geology. U of 0 San Cristobal Geology INAA of Selected Geological USDOE A. R. McGirney Specimens from the Galapagos D. Geist Islands in an Attesyt to Identify the Mantle Sources for the Laves & Detemine Tectonic Origfn of the Islands

?

t;

Tatie 4.6 (continued)

Listing Rame of Person (s)

Department and mueer Ustag Reactor Institution.

Project Title Description Funding Agency 46 G. Goles Geology. U of 0 Geochemistry of Domes INAA of Selected Geological U500E R. A. Schmitt Near Crater Lake Samples for Geochemical Analysts W. W. C11agmen 47 E. Geles Geology. U of 0 Tuffaceous Palaev INAA of Tuffaceous Sediments From U500E R. A. Schaftt Sediments The Midland Valley gf Scotland G. J. Reta11ack and From the Fort Ternen Area of Kenya to Estabitsh Whether Carbonatttic Volcanism of Palaeozofc Age Occurred in The Northern British Isles.

48 E. Goles Geology U of 0 Calapocya Thesis INAA of Volcanic Samples From U500E The Western Cascades in Order to R. A. Schaftt Document a Tholeifttc Suite of A. R. Metfrney S. Ritchie

'ertfary Laves and Determine

~ heir Genetic Relationship to he Orogenic Rocks of the Cascade Wolcanic Series og G. Geles Geology U of 0 Geology & Geochemistry INAA of Geological Samples From U500E R. A. Schaftt of Marchena Island.

rehena Island to Analyze Each

. A. R. Mctfreey Galapagos D.;;ernable Stratigraphic Horizon E. Vicenzt in Addition to Xeno11ths Trans-ported to the Surface by Pyro-clastic Eruptions.

50 G. Geles Geology. U of 0 Colueta Rtver Basalt Continuation of Studies of U500E R. A. Schmitt Stratigraphy and Stratigraphic Succession and Petrogenests Petrogenetic Origins of Columbia i

I River Basalt Flows l'

SI G. Goles Geology. U of 0 Geochemistry Of INAA of the Samples From the U500E R. A. Schmitt Paracutta Volcano Paracutta Volcano in Mexico to E. Vicenzt

  • (Mexico)

Determine the Causes of the Abrupt Shifts in Lava Type and Compost-tion 52 E. Goles Geology. U of 0 Highmoods Analysis INAA of Sulk Rocks & Mineral U500E R. A. Schmitt Separates From Pseudo-Leccite-R. Barry Bearing Intrusive Rocks From The Highmood Mountains. MT e

5

4-19 Table 4.7 Summary of Visitors to the OSTR July 1,1984 through June 30, 1985 l

No. of Date Visitors Name 07-26-84 15 Adventures in Learning 07-31 10 English Language Institute 10-16-84 10 OSU Chemistry Dept. (Chem. 419) i 11-01-84 40 OSU Chemistry Dept. (Chem 107/207) 1 11-08-84 40 OSU Chemistry Dept. (Chem 107/207) 11-26-84 7

Sichuan University, PRC 01-29-85 22 Tigard High School Science Students 01-30-85 12 English Language Institute 02-02-85 40 Beaver Open House 01-11-85 12 English Language Institute 02-16-85 82 Dad's Weekend Open House 02-20-85 15 Coquille High School Physics Class 03-01-85 6

Oregon Episcopal School 03-11-85 12 Problems in Safety Health 482 03-22-85 10 Community College Science Advisors 04-11-85 20 LBCC Physical Science Class 04-20-85 10 Albany High School Science Students 04-25-85 7

University of Oregon (Geol. 420) 04-25-85 S105 E-Spree Day High School Students 04-30-85 24 OSU Chemistry Dept. (Chem 206) 05-04-85 45 Moms' Weekend Open House 05-29-85 18 Westernview Intermediate School 06-04-85 12 Fujan Higher Ed. Delegation 06-13-85 25 Up With People 769

PART 5 OSTR ENVIRONMENTAL AND RADIATION PROTECTION DATA

\\

Table of Contents PART 5 OSTR ENVIRONMENTAL AND RADIATION PROTECTION DATA (July 1, 1984 through June 30,1985)

A.

INTRODUCTION........................................................

5-1 B.

A

SUMMARY

OF THE NATURE AND AMOUNT OF RADI0 ACTIVE EFFLUENTS RELEASED OR DISCHARGED TO THE ENVIRONS BEYOND THE EFFECTIVE CONTROL OF THE LICENSEE, AS MEASURED AT OR PRIOR TO THE POINT OF SUCH RELEASE OR DISCHA RGE........................................

5-1 1.

Liquid Waste (Summarized on a Monthly Basis)....................

5-1 a.

The radioactivity discharged during the reporting period based on the following:.....................................

5-1

1) The total estimated quantity of radioactivity released

( to the sani tary sewer) (in curies ).....................

5-1

2) The detectable radionuclides present in this waste......

5-1

3) An estimate of the specific activity for each detectable radionuclide present, if the specific activity of the released material after dilution was greater than 1 x 10-7 microcuries/ cubic centimeter...................

5-2

4) A summary of the total release (in curies) for each radionuclide identified in 2) above for the reporting period, based on representative isotopic analysis.......

5-2

5) The estimated average concentration of the released radioactive material at the point of release for the reporting period (in terms of microcuries/ cubic centimeter) and the fraction of the applicable MPCvalue...............................................5-2 b.

The total volume (in gallons) of effluent water (including diluent) released during each period of release.............

5-2 2.

Gaseous Waste (Summarized on a Monthly Basis)...................

5-2 a.

The radioactivity discharged during the reporting period based on the following:.....................................

5-2

1) The total estimated quantity of radioactivity released (in curies) determined by an appropriate sampling and c o u n t i n g me t h od.........................................

5-2 l

2) -The detectable radionuclides present in this waste......

5-2

3) The total estimated quantity of argon-41 released during the reporting period (in curies), based on data from an appropriate monitoring system...........................

5-2

4) The estimated average atmospheric diluted concentration of argon-41 released during the reporting period (in terms of microcuries/ cubic centimeter) and the fraction of the applicable MPC va1 ue.............................

5-2

5) The total estimated quantity of radioactivity in particulate form with half-lives greater than eight days released during the reporting period (in curies),

as determined by an appropriate particulate monitoring system..................................................5-2

6) The average concentration of radioactive particulates with half-lives greater than eight days released during the reporting period (in microcuries/ cubic centimeter)..

5-3

7) An estimate of the average concentration of other significant radionuclides present in the gaseous waste discharge (in terms of microcuries/ cubic centimeter) and the fraction of the applicable MPC value for the reporting period, if the estimated release was greater than 20% of the applicable MPC..........................

5-3 3.

Solid Waste (Summarized on an Annual Basis).....................

5-3 a.

The radioactivjty discharged during the reporting period based on the following:.....................................

5-3

1) The total amount of solid waste packaged (in cubic feet). 5-3
2) The detectable radionuclides present in this waste......

5-3

3) The total radioactivity in the solid waste (in curies)..

5-3 b.

The dates of shipment and the disposition of solid wastes

( i f shi pped o f f si te )........................................

5-3 C.

AN ANNUAL

SUMMARY

OF THE RADIATION EXPOSURE RECEIVED BY FACILITY PERSONNEL AND BY VISITORS IN TERMS OF THE AVERAGE RADIATION EXPOSURE PER INDIVIDUAL AND THE GREATEST EXPOSURE PER INDIVIDUAL FO R E AC H OF THE TWO GR0VP S..........................................

5-3 D.

AN ANNUAL

SUMMARY

OF THE RADIATION LEVELS AND THE LEVELS OF CONTAMINATION OBSERVED DURING ROUTINE SURVEYS PERFORMED AT THE FACILITY, IN TERMS OF THE AVERAGE AND THE HIGHEST LEVELS............

5-3

E.

THE LOCATION AND MAGNITUDE OF THE MAXIMUM MEASURED OR CALCULATED DIRECT RADIATION LEVEL IN UNRESTRICTED AREAS DUE TO DIRECT RADIATION FROM THE FACILITY, AND DIRECT RADIATION FROM FACILITY EFFLUENTS...........................................................

5-4 1.

The Maximum Direct Radiation Level in Unrestricted Areas Due to Direct Radiation From the Facility...........................

5-4 2.

The Maximum Direct Radiation Level in Unrestricted Areas Due to Direct Radiation From the Facility Effluents.................

5-8 F.

A DESCRIPTION OF THE GENERAL METHODS USED AND AN ANNUAL

SUMMARY

OF THE RESULTS OF ENVIRONMENTAL SURVEYS PERFORMED OUTSIDE THE FACILITY................................................

5-14 1.

The Onsite Environmental Radiation Monitoring Program...........

5-14 2.

The Offsite Environmental Radiation Monitoring Program..........

5-17 3.

An Annual Summary of Onsite and Offsite Environmental Radiation Monitoring Results..............................................

5-19 a.

Reactor Facili ty Stack Moni tor (0nsi te).....................

5-20 b.

Reactor Facility Area Monitoring Composite Dosimeters, Reactor Fence TLDs and Integrating Ionization Chambers.

and Direct Radiation Measurements (0nsite)..................

5-20 c.

Analysis of Reactor Contributed Radioactivity in Liquid Effluents (0nsite)..........................................

5-21 d.

Soil, Water, and Vegetation Monitoring (0ffsite)............

5-22 e.

Ai rborne Gamma Moni tori ng (0f fsi te).........................

5-23 G.

REFERENCES..........................................................

5-26

List of Tables Table Page 5.1 Monthly Summary of Liquid Waste Discharges for the Year July 1, 1984 Through June 30, 1985..........................

5-27 5.2 Monthly Summary of Gaseous Waste Discharges for the Year July 1, 1984 Through June 30, 1985..........................

5-28 5.3 Annual Sumary of Solid Waste Discharges for the Year July 1, 1984 Through June 30, 1985..........................

5-29 5.4 Annual Sumary of Radiation Exposure Received by Facility Personnel and Visitors for the Year July 1, 1984 Through J u n e 3 0, 19 8 5...............................................

5 - 3 0 5.5 Annual Sumary of Radiation Levels and Contamination Levels Observed Within the Reactor Facility During Routine Radiation Surveys for the Year July 1, 1984 Through June 30, 1985.....

5-31 5.6 Total Dose Equivalent Recorded on Operating Area Composite Dosimeters Located Inside the TRIGA Reactor Facility for the Year July 1, 1984 Through June 30, 1985.....................

5-32 5.7 Total Dose Equivalent at the TRIGA Reactor Area Fence for the Year July 1, 1984 Through June 30, 1985.................

5-34 5.8 Annual Average Concentration of the Total Net Beta Radio-activity (Minus 3 ) for Offsite Environmental Soil, Water, ii and Vegetation Samples for the Year July 1, 1984 Through June 30, 1985...............................................

5-35 5.9 Total Dose Equivalent at the Offsite Airborne Gama Monitoring Stations for the Year July 1, 1984 Through June 30, 1985...............................................

5-38 i

List of Figures Figure Page 5.1 Operating Area Composite Dosimeter Locations for the TRIGA Reactor Building External Wal l s......................

5-39 j

5.2 Area Radiation Monitor Locations for the TRIGA Reactor, and on the TRIGA Reactor Aiea Fence........................

5-40 5.3 Monitoring Stations for the OSU TRIGA Reactor for the Year July 1, 1984 Through June 30, 1985.........................

5-41 e

I r

a v

5-1 PART 5 OSTR ENVIRONMENTAL AND RADIATION PROTECTION DATA (July 1, 1984 through June 30,1985)

A.

INTRODUCTION The data contained in this section have been prepared to comply with the current requirements of Nuclear Regulatory Commission (NRC)

Facility License No. R-106 (Docket No. 50-243) and the Technical Speci-fications contained in Appendix A to that license. The material has also been prepared in compliance with Oregon Department of Energy Rule No. 345-30-010, which requires an annual report of environmental effects due to research reactor operations.

Within the scope of Oregon State University's radiation protection program, it is standard operating policy to maintain all releases of radioactivity to the unrestricted environment and all occupational exposures to radiation and radioactive materials at levels which are consistently "as low as reasonably achievable" (ALARA).

B.

A SU MARY OF THE NATURE AND AMOUNT OF RADI0 ACTIVE EFFLUENTS RELEASED OR DISCHARGED TO THE ENVIRONS BEYOND THE EFFECTIVE CONTROL OF THE LICENSEE, AS MEASURED AT OR PRIOR TO THE POINT OF SUCH RELEASE OR DISCHARGE.

1.

Liquid Waste (Summarized on a Monthly Basis) a.

The radioactivity in liquid waste discharged during the applicable reporting period has been summarized according to the following items. All liquid waste data pertaining to these items are contained in Table 5.1.

1) The total estimated quantity of radioactivity released (to the sanitary sewer) (in curies).
2) The detectable radionuclides present in this waste.

i

5-2

3) An estimate of the specific activity for each detectable radionuclide present, if the specific activity of the released material after dilution was greater than 1 x 10-7 microcuries/ cubic centimeter.
4) A summary of the total release (in curies) for each radionuclide identified in 2) above for the reporting period, based on representative isotopic analysis.
5) The estimated average concentration of the released radioactive material at the point of release for the reporting period (in terms of microcuries/ cubic centimeter) and the fraction of the applicable MPC value.

b.

The total volume in gallons of effluent water (including diluent) released during each period when liquid waste was released also has been summarized in Table 5.1.

2.

Gaseous Waste (Sumarized on a Monthly Basis) a.

The radioactivity in gaseous waste discharged during the applicable reporting period has been summarized according to the following items. All gaseous waste data pertaining to these items are contained in Table 5.2.

1) The total estimated quantity of radioactivity released (in curies) determined by an appropriate sampling and counting method.
2) The detectable radionuclides present in this waste.
3) The total estimated quantity of argon-41 released during the reporting perfod (in curies), based on data from an appropriate monitoring system.
4) The estimated average atmospheric diluted concentration of argon-41 released during the reporting period (in terms of microcuries/ cubic centimeter) and the fraction of the applicable MPC value.
5) The total estimated quantity of radioactivity in particulate form with half-lives greater than eight days relused during the reporting period (in curies), as determined by an appropriate particulate monitoring system.

i 5-3

6) The average concentration of radioactive particulates with half-lives greater than eight days released during the reporting period (in microcuries/ cubic centimeter).
7) An estimate of the avc-rage concentration of other signifi-cant radionuclides present in the gaseous waste discharge (in terms of microcuries/ cubic centimeter) and the fraction of the applicable MPC value for the reporting period, if the estimated release was greater than 20% of the appli-cable MPC.

3.

Solid Waste (Summarized on an Annual Basis) a.

The radioactivity in solid waste discharged during the applicable reporting period has been summarized according to the following items. All solid waste data pertaining to these items are contained in Table 5.3.

1) The total amount of sclid waste packaged (in cubic feet).
2) The detectable radionuclides present in this waste.
3) The total radioactivity in the solid waste (in curies).

b.

The dates of shipment and the disposition of solid wastes (if shipped offsite) also have been listed in Table 5.3.

C.

AN ANNUAL SUMARY OF THE RADIATION EXPOSURE RECEIVED BY FACILITY PERSONNEL AND BY VISITORS, IN TERMS OF THE AVERAGE RADIATION EXPOSURE PER INDIVIDUAL AND THE GREATEST EXPOSURE PER INDIVIDUAL FOR EACH OF THE TWO GROUPS.

The annual summary of the radiation exposure received by facility personnel and by visitors for the applicable reporting period has been included in Table 5.4.

D.

AN ANNUAL SUMARY OF THE RADIATION LEVELS AND THE LEVELS OF CONTAMINATION OBSERVED DURING ROUTINE SURVEYS PERFORMED AT THE FACILITY, IN TERMS OF IHE AVERAGE AND THE HIGHEST LEVELS.

The annual summary of radiation and contamination levels observed during routine facility surveys for the applicable reporting period has been included in Table 5.5.

5-4 E.

THE LOCATION AND MAGNITUDE OF THE MAXIMUM MEASURED OR CALCULATED DIRECT RADIATION LEVEL IN UNRESTRICTED AREAS DUE TO DIRECT RADIATION FROM THE FACILITY AND DIRECT RADIATION FROM FACILITY EFFLUENTS 1.

The Maximum Direct Radiation Level in Unrestricted Areas Due to Direct Radiation from the Facility The location and magnitude of the maximum (measured and calculated) direct radiation level in an unrestricted area due to direct radiation from the facility can best be understood by referencing Figures S.1 and 5.2, and Tables 5.6 and 5.7.

Early in the operating history of the OSU TRIGA reactor, two potential sources of direct radiation from the TRIGA facility were identified.

These were the demineralizer tank for the reactor primary water system and the graphite-natural uranium subcritical pile located in the main reactor room (see Figure 5.1).

On January 3, 1972, the demineralizer tank was removed from its original position, shown in Figure 5.1, and was moved to location "A" in Figure 5.1.

Henceforth, it ceased to be a major contributor to the direct radiation from the facility.

On February 23, 1972, the east side (the exterior wall side) of the subcritical pile and the entire demineralizer tank were conservatively shielded with concrete and lead, further limiting any small direct radiation contribution from the demineralizer tank and effectively reducing the direct radiation to unrestricted areas from both the subcritical pile and the demineralizer tank to essentially zero millirem per year.

With the elimination of the preceding two sources of direct radiation from the facility, two additional sources of lesser magnitude became apparent. One of '.hese was the particulate filter for the reactor primary water system, which is located on the demineralizer platform (see Figure 5.1), while the second is best collectively termed " normal use of reactor experimental facilities and operating areas for research and teaching."

5-5 The particulate filter was completely shielded by July 10, 1972, and the new shield eliminated any further radiation contribution in unrestricted areas from this source.

The second source, relating to normal use of the OSU research reactor, takes into consideration the routine handling of radioactive materials within the entire facility, and the need for relatively frequent access into reactor experimental and irradiation facilities.

Both of these latter activities create a small potential for very low level direct radiation exposure (of reactor facility origin) in immediately adjacent unrestricted areas.

Surveillance over direct radiation levels in unrestricted areas (which potentially may arise from inside the TRIGA facility) is maintained by utilizing four different types of routine area radiation measurements.

These measurements include data from t

a continuously operating 14-channel area radiation monitoring system inside the facility, with remote detector stations located throughout the TRIGA operating area, plus results obtained by numerous (and in many cases, daily) on-the-spot direct radiation measurements made inside and outside the facility by members of the radiation protection staff during TRIGA operations.

In addition, data from integrating area monitoring composite dosimeters installed at strategic locations within the TRIGA reactor operating area are routinely documented and are used to indicate locations where direct radiation from the facility might be entering unrestricted areas. The composite dosimeter data can be corrected, as needed, to reflect radiation attenuation in the reactor facility walls.

Finally, assessment of direct radiation levels in unrestricted areas is conducted on the basis of area monitoring data collected through our thermoluminescent dosimetry (TLD) program. Most of the TLDs in this program are actually located in unrestricted areas, or are located on the TRIGA reactor area fence which surrounds the accessible sides of the TRIGA reactor building (see Figure 5.2).

Therefore, these monitors are a valuable source of information for assessing the likelihood of radiation doses in unrestricted areas due to direct radiation from the TRIGA facility.

5-6 The specific locations of pertinent vendor supplied area monitoring composite dosimeters (consisting of a beta-gamma film plus a CR-39 polycarbonate plastic track-etch neutron dosimeter) inside the restricted operating area at the OSU TRIGA facility are shown in detail in Figure 5.1, and are again shown as part of an overall area diagram in Figure 5.2.

For the period involved in this year's report, there was one vendor for the composite dosimeters, namely Radiation Detection Company (R.D. Co.), Sunnyvale, California.

Figure 5.2 also identifies the area monitoring stations on the reactor arca fence.

For the 1984-85 reporting period, each of these fence stations utilized OSU supplied and processed TLD area monitors (normally three Harshaw 7LiF TLD-700 chips per monitor) and Radiation Detection Company (R.D. Co.) CaSO4 TLD area monitors (2 CaSO4 TLDs per monitoring packet).

The R.D. Co. TLDs were started during the 1977-78 reporting period to replace R.D. Co.

beta-gamma-neutron film packs, which were used previously at the reactor fence monitoring stations.

R.S. Landauer Co. TLD monitors were started July 1,1981 and were used throughout the 1981-82 reporting period along with the R.D. Co. TLD monitors.

Because

{

the results from the two vendors werc very similar, in July of 1982 we returned to R.D. Co. as our only vendor of TLD monitors for the-fence and other offsite environmental monitoring stations.

OSU will also continue to supply and process TLD area monitors as we have in the past.

With the addition of the fence around the reactor area (in September of 1972), area monitoring data from inside the TRIGA facility (contained in Table 5.6) no longer have a high degree of correlation to direct radiation levels in surrounding unrestricted areas. Nevertheless, we believe the data from inside the facility reflect the general character of our operation and therefore we plan to continue including it in all reports of this type.

In Figures 5.1 and 5.2 composite dosimeter area monitoring locations within the TRIGA reactor facility are abbreviated to indicate their position on a north, south, east, or west wall of the main reactor bay, or their locations in the reactor's adjacent heat exchanger room.

For example, MRCTSE is interpreted as M_onitor

-.-.- =. - - -

1 5-7

' Radiation Center _TRIGA, South dosimeter, East wall of the main

]

reactor bay building.

Similarly, MRCTHXS is the dosimeter for the adjacent Heat Exchanger room, S_outh wall. Monitoring locations on the reactor area fence are simply designated MRCFE-1 through l

MRCFE-9, and imply fjonitor R_adiation Center F_ence E_nvironmental, followed by the monitoring station number.

After the addition of the previously described shielding inside the reactor facility and the addition of the reactor area fence, direct radiation levels in unrestricted areas due to the j

TRIGA facility dropped to essentially background radiation levels.

Data presented in Table 5.6 show the generally low annual doses i

recorded inside the reactor facility's operating area.

Likewise, Table 5.7 provides information regarding the low annual doses at the reactor area fence, based on three different groups of

~

radiation measurements.

Specifically, Table 5.7 includes results from the two different groups of area monitoring TLDs which were located on the reactor area fence, plus data from the direct micro-roentgen-per-hour exposure rate. measurements collected at each fence area monitoring station. See footnote (6) of Table 5.7 for a further explanation of the pR/hr data and its application.

Most importantly, however, use of the data in Tables 5.6 and 5.7 demonstrates that the total annual radiation dose in the unrestricted areas adjacent to the reactor area fence generally. falls within the rather broad dose range-typically expected for natural back-ground radiation in Oregon.

As a final note on the fence monitoring stations, it should

-be pointed out that throughout the full year period covered by this report there was no continuous occupancy, and little or no i

occupancy of any. duration, in the unrestricted area along the entire perimeter of the reactor facility fence.

In addition, there was only very intermittant, short duration occupancy in the area-between the reactor fence and the reactor building.

OSU has. continued its efforts to achieve close agreement between R.D. Co. '(our regular vendor for area monitoring and envi-ronmental TLDs) and OSU TLD data.

Present control and QA procedures used by OSU for its outside dosimetry vendor will continue to

~be carefully reviewed, and will be modified as deemed necessary.

5-8 In line with our commitment to maintain surveillance over vendor-supplied TLD results, for the 1981-82 reporting year OSU tried an additional TLD vendor (R.S. Landauer, Jr. and Co.) for area and environmental monitoring.

To facilitate comparison of TLD results between vendors and to prevent loss of data from the monitoring locations currently being reported, it was considered necessary to use TLDs from the new vendor along with those from R.D. Co.

As indicated earlier, TLD results from the two vendors appeared to be very similar and were normally within the statistical range of values obtained by OSU. Because of this, OSU continued to use only one outside TLD vendor (Radiation Detection Co.) for the 1984-85 reporting period.

2.

The Maximum Direct Radiation Level in Unrestricted Areas Due to Direct Radiation from the Facility Effluents.

The location and magnitude of the maximum (measured and calcu-lated) direct radiation level in unrestricted areas due to direct radiation from facility effluents will be reviewed in light of both liquid and gaseous releases.

As reported in Table 5.1, the total annual quantity of radio-activity released in liquid effluents has been quite small.

The microcurie quantity for the reporting period in even a few hundred cubic centimeters of solution would not normally present a significant direct radiation potential, particularly when the radionuclide composition of the radioactivity is examined.

In our particular operation, the majority of the liquid radioactive effluent is now normally associated with a single annual demineralizer resin change. When released from the reactor facility, potentially radioactive liquid is mixed in a holdup tank on a batch basis with up to 3,000 gallons of waste water from the Radiation Center laboratories before final discharge into the unrestricteed area (the sanitary sewer system).

The annual average concentration for total reactor facility radioactivity in liquid effluents entering the unrestricted area equaled 7.26 x 10-6 pCi/cc for the year of July 1, 1984 through J

5-9 June 30, 1985. With respect to this value and the total radioacti-vity released in the liquid effluent, recall that no city water background radioactivity has been substracted. Also, note that the main contributor to the total microcuries released was tritium (65.0 pCi of tritium out of a total of 65.03 pCi released). Even though nearly all of the liquid effluent volume from the reactor facility originated during the annual changing of the demineralizer resins, it appears that little of the tritium was of reactor origin.

Our routine analysis of Corvallis city water over the past four years indicates a normal variation in tritium background concen-tration within a range of 1.70 x 10-5 pCi/cc to 1.92 x 10-6 pCi/cc for the years July 1, 1981 through June 30, 1985.

Our annual average concentration for tritium based on all liquids released to the unrestricted area from the reactor facility was within this range at 7.26 x 10-6 pCi/cc for the year July 1,1984 through June 30, 1985.

If the tritium is omitted from the total radioactivity released in the reactor's liquid effluent and a calculation performed using the remaining radioactivity (s0.03 pCi), some of which was also possibly city water background, the annual average concentration l

for reactor facility radioactivity entering the unrestricted area becomes 3.35 x 10-9 pCi/cc for the year July 1,1984 through June 30, 1985.

In view of the radionuclides present, and the relative abundance of each, it can be easily determined (as shown in Table 5.1) that the annual average concentration of total reactor facility radio-activity in reactor related liquid effluents represents but a small fraction (0.25% or 0.0075%--see Table 5.1) of the applicable unrestricted area concentration limits.

In addition, the average pCi/cc concentrations stated above DO NOT take into consideration the additional mixing of these liquid discharges with approximately 95,000 to 115,000 gallons per year of liquids and sewage normally_

discharged by the Radiation Center complex into the same sanitary sewer system.

For these reasons, we have concluded that the direct radiation to unrestricted areas due to radioactivity in reactor liquid effluents has been negligible.

5-10 On pages 4-53 through 4-58 of the Safety Analysis Report (SAR) for the OSU TRIGA Research Reactor, dated August 1968, consideration is given to the routine discharge and atmospheric dilution of gaseous effluents from the reactor facility.

In this particular analysis in the 1968 SAR, the evaluations were conducted using the original TRIGA facility stack height of 55 feet above ground level.

Furthermore, on pages 4-53 and 4-57 of the 1968 SAR it is specified that the continuous radioactivity discharge rate assumed for the purpose of evaluating effluent dilution and for dose calculations was 100 MPC, meaning 100 times the normal 4 x 10-8 pCi/cc argon-41 unrestricted area maximum permissible concentration, or a continuously released concentration of argon-41 equaling 4 x 10-6 pCi/cc. On page 4-58 (Table 4.11 of the 1968 Safety Analysis Report), it is concluded that under the most unfavorable atmospheric conditions (with the SS-foot stack) a person standing on the ground for a full year at the point of maximum argon-41 concentration would be exposed to less than 9% (8.53%) of the normal unrestricted area MPC for argon-41. As a result, a person could stand on the ground at that point continuously for one year (year after year) under the most unfavorable atmospheric conditions, while the reactor operated continuously at 1000 kW, (and continuously discharged an assumed worst case concentration of 4 x 10-6 pCi/cc of argon-41) and receive a whole body gamma dose from argon-41 of less than 45 mrem (42.6 mrem) integrated over an entire year's occupancy.

Since the OSU TRIGA does not operate on a 24-hour per day basis, does not operate continuously at 1000 kW while it is operating, and does not discharge argon-41 at 4 x 10-6 Ci/cc while operating at 1000 kW, the annual average argon-41 concentration, as measured by the facility stack monitor, has always been much less than the assumed calculational value of 4 x 10-6 pCi/cc. Consequently, the maximum annual dose in the unrostricted area due to direct c

radiation from gaseous effluents has also been significantly less than the nominal 45 mrem per year value conservatively projected in the 1968 Safety Analysis Report.

As indicated in OSU's May 16, 1973 report of 10 CFR 50.59 ftems to the former USAEC Division of Reactor Licensing, (a copy of which also went to the former Oregon Nuclear and Thermal Energy

5-11 Council) on February 23, 1972, the TRIGA facility stack height was increased from its original 55 feet above the ground to 65 feet, 10 inches above ground level. As a result of the new stack height, new atmospheric dispersion calculations were necessary in order to evaluate the atmospheric dilution of gaseous effluents from the reactor facility and to predict the curresponding radiation doses in the unrestricted area from these diluted effluents. The results of the original 1968 atmospheric dilution and dose calcu-1 lations and the first such evaluation following the stack height change were included in Table 2 of OSU's May 16, 1973 10 CFR 50.59 report to the USAEC.

The data in this report indicated a slightly lower concentration at the point of maximum concentration on the ground because of the higher stack. Additional plume dispersion studies during 1973 and 1974, and again during 1978 using USNRC Regulatory Guide 1.111, evaluated the influence of the new stack height on gaseous effluent dispersion and corresponding dose, and essentially confirmed earlier data.

Only a slight change is intro-duced if the most unfavorable values from the expanded 1973-74 study and the newer 1978 study are used.

Using the same basic assumptions employed for the shorter stack and, in particular, a continuous argon-41 discharge rate of 100 MPC, the 1973-74 results indicated that for atmospheric conditions giving the highest ground concentration of argon-41 (i.e., the worst atmospheric conditions) a person standing at the point of maximum concentration on the' ground would encounter approximately 3.018% (as opposed to 2.85% in the 1972 report) of the unrestricted area MPC for argon-41.

Furthermore, the 1978 study produced a nearly identical value of 3.005% of the unrestricted area argon-41 MPC. As a result, a person could stand at this point of maximum concentration on the ground (currn.ly projected to be 130 meters from the stack as opposed to 150 meters in the 1973-74 calculation, and 135 meters in the 1972 report) continuously for one year under the worst atmospheric conditions, while the reactor continuously discharged 100 times the argon-41 MPC, (i.e.,

4 x 10-6 pCi/cc) and receive a whole body gamma dose from argon-41 of15(15.03) mrem integrated over an entire year's occupancy.

5-12 As we have indicated, the OSU TRIGA does not operate on a 24-hour per day basis nor does it operate continuously at 1,000 kW. Also, the facility's annual average argon-41 concentration is always much lower than the 4 x 10-6 pCi/cc value used for purposes of calculation. As a result, the maximum annual dose in the unrestricted area due to direct radiation from gaseous effluents of reactor origin consistently remains much less than the nominal 15 mrem per year dose projected by using the new stack height and the 1978 plume dispersion data.

In order to arrive at the most conservative estimate of the maximum dose in the unrestricted area due to direct radiation from OSTR gaseous effluents dG ing the reporting period, one should assume continuous annual occupancy at the point of maximum argon-41 concentration or, the ground. Furthermore, it will be necessary to assume the existence of the most unfavorable meteorological conditions for a full year in order to achieve the maximum concen-tration at the specified point for one entire year.

If these highly conservative (and, for all practical purposes, impossible) assumptions are applied in conjunction with the reported annual average argon-41 concentration (5.70 x 10-8 pCi/cc),asderived from actual measurements at the point of release with the facility's continuous stack monitor (see Table 5.2), then the maximum annual dose in the unrestricted area (at 130 meters from the stack under the most unfavorable atmospheric conditions) would be approximately 0.21 mrem for the year July 1, 1984 through June 30, 1985.

Even in the presence of an essentially negligible argon-41 dose contribution in the unrestricted area, which has been repeatedly verified by using the most conservative assumptions in dose cal;u-lations and by a longstanding environmental monitoring program in the unrestricted area, OSU chose to implement several actions during the 1981-1982 reporting period (and during later periods) designed to minimize argon-41 release even further, and to clearly demonstrate our continuing commitment to the as-low-as-reasonably-achievable (ALARA) concept relative to argon-41 discharge. As expected, these measures, and others implemented later, proved effective in reducing even further the barely detectable concen-

5-13 tration of argon-41 from the OSTR, but had no measurable impact on detectable dose in the environment since this was already well below detection thresholds.

Nevertheless, during the current reporting period the argon-41 released and the corresponding theo-retical dose commitment in the unrestricted area was lower. As, noted in Table 5.2, Footnote 3, the total argon-41 released during this reporting period decreased by about 25.7% with respect to last year's value, although the megawatt-days of operation during both reporting periods were nearly the same (1984-85 showed a 0.3% increase in megawatt-days).

The observed reduction in argon-41 released during this reporting period was due to a full year's use of several 1981-82, 1982-83 and 1983-84 modifications in the reactor's experimental facilities ventilation system (usually termed the argon ventilation system).

The two changes which had the greatest impact on minimizing argon-41 releases were the addition of a nitrogen purging system to the ventilation scheme for the rotating rack facilty and the reduction of room air flow through the thermal column.

In the first situation, nitrogen gas from a liquid nitrogen tank flows through the rotating rack in place of normal room air; while in the case of the thermal column, ventilation flow valve adjustments were made which resulted in much less room air being passed through this facility. Also, during the 1983-84 reporting period, much more sensitive devices for indicating and adjusting air flow were installed on the ventila-tion lines for the thermal column and oeam ports 1 and 3, which allowed much better adjustment of the (room) air flow through these facilities and a further reduction in argon-41 release.

Since the rotating rack, the thermal column and the two beam ports currently in use represent the major potential sources of argon-41 generation due to neutron activation of argon-40 in normal atmo-spheric-air in these facilities, the elimination or reduction of this target argon isotope significantly reduces the already vey low argon-41 producticn and release from the OSTR.

Another modification to the entire argon ventilation system (during the 1982-83 interval) added a positive exhaust-isolation valve into the system's discharge line.

This valve was installed

5-14 at a point just before the argon vent line joins the main reactor building exhaust stream, and the valve is normally closed at the end of the operiting day when the argon ventilation system is shut off.

Closure of this valve eliminates any further escape of argon-41 from this system, and since argon-41 has a 1.83 hour9.606481e-4 days <br />0.0231 hours <br />1.372354e-4 weeks <br />3.15815e-5 months <br /> half-life, it decays overnight while the argon ventilation system is shut off and secured.

A similar exhaust-isolation valve was also added to the pneumatic-transfer system discharge line (in the 1982-83 interval) just before it joins the main reactor building exhaust stream.

This valve will also be kept closed, except during times when the pneumatic-transfer system is in use.

Keeping the valve closed eliminates a small induced air flow through the system caused by a lower pressure in the reactor building exhaust stream.

Elimination of this air flow through the pneumatic-transfer system's in-core region eliminates any possible argon-41 production during periods of non-use, and thereby contributes even further to the reduction in total argon-41 released.

F.

A DESCRIPTION OF THE GENERAL METHODS USED AND AN f.NNUAL SulMARY OF ThE RESULTS OF ENVIRONMENTAL SURVEYS PERFORMED OUTSIDE THE FACILTIY The overall environmental radiation monitoring effort will be categorized according to "onsite" and "offsite" environmental radiation monitoring programs. A description of the two environmental monitoring program categories follows.

1.

The Onsite Environmental Radiation Monitoring Program The onsite environmental radiation monitoring program currently incorporates the TRIGA facility radioactivity stack monitor, the onsite area monitoring composite dosimeters (consisting of a film badge and a CR-39 plastic track-etch neutron detector), the onsite area monitoring TLDs, the onsite 0-200 mrem gamma-sensitive inte-grating ionization chambers (self-reading pocket dosimeter type),

and the monitoring procedures associated with the analysis of radioactivity in liquid effluents from the reactor facility.

Also, routine (daily, weekly, and monthly) radiation surveys con-

5-15 ducted by the OSU TRIGA radiation protection staff provide a wealth of essential information on existing radiation conditions throughout the various onsite areas.

The reactor facility dual channel radioactivity stack monitoring system consists of a continuously-moving-filter-paper particulate monitoring channel, followed by a separate chamber and detector which function together as the gas monitoring channel.

The system is consistently placed in' operation before the reactor is started up, remains in operation at all times while the reactor is in use, and is kept operable after reactor shutdown until both detection channels reach normal background or it is determined by other means that no significant radioactivity is being discharged from the stack. The system is equipped with an isokinetic sampling head which draws its sample near the point of discharge in the reactor building stack.

The particulate channel is calibrated at least annually with standardized particulate samples containing NBS traceable radioactivity of an appropriate type and energy, and the gas channel is calibrated at the same frequency with known quantities of argon-41 gas.

The system reaas out continuously in both the particulate and gaseous channels, with each channel having its own count rate meter and recorder.

A count integrating scaler is also attached to the gas channel to increase the accuracy in determining the argon-41 released.

The system is equipped with alarm circuits which will automatically shut off the facility ventilation system fans and close dampers on the intake and exhaust ventilation lines in the event preset airborne radioactivity concentration limits are reached. One of the most valuable applications of this system from the standpoint of environmental monitoring is the data derived from its operation which can be applied to determining potential exposures in unrestricted areas from gaseous radioactive effluents, namely argon-41.

Onsite area-monitoring composite dosimeters each consist of a standard personnel-type beta-ga.ama film pack and a CR-39 plastic track-etch neutron detector, located at strategic positions inside the reactor facility operating area (see Figures 5.1 and 5.2).

The composite dosimecers within the facility are changed onco per month.

5-16 During the 1984-85 reporting period, onsite area monitoring using TLDs consisted of two different types of dosimeters, both located at identical positions on the reactor area fence (see Figure 5.2).

One type of TLD monitor was supplied and interpreted by Radiation Detection Company (R.D. Co.), Sunnyvale, California.

This system utilized CaSO4 TLDs (2 CaSO4 TLDs per monitoring pack) prepackaged by R.D. Co. and exchanged on a quarterly basis. The R.D. Co. TLDs were placed in thin sheet metal boxes located on the reactor area fence, and were accompanied at each location by the second TLD monitoring package which was prepared and inter -

preted by OSU.

Each OSU TLD monitoring device normally consisted of three lithium fluoride chios, presently Harshaw ILD-700s, ex-changed on a quarterly basis.

Prior to April 1976, each OSU supplied onsite TLD monitoring device was first packaged in a plastic mount which was tnen placed inside an outer container made out of thin-walled copper tubing.

The copper tube was subsequently taped to the reactor area fence.

The plastic mount and copper container were essentially identical to those being used at the time by the Oregon Radiation Control Section in their TLD monitoring program.

In April of 1976, the copper tube outer containers were dis-continued for the OSU-supplied TLDs on the reactor area fence.

As an alternative, the original inner plastic mounts were placed inside the thin sheet metal boxes (mentioned above) which are located at each of the reactor area fence monitoring stations.

This was done to reduce data-loss due to increasino theft of the small copper tube TLD packs. OSU and R.D. Co. TLD packs were located at each of the nine reactor area fence monitoring positions (identified in Figure 5.2) during the current reporting period.

In addition to the above radiation monitoring devices, each of the nine reactor area fence monitoring positions is presently (and will continue to be) equipped with two 0-200 mrem gamma-sensitive integrating ionization chambers (self-reading pocket dosimeter type). These dosimeters are located inside the thin sheet metal box at each fence monitoring station which also contains the pre-i

5-17 viously mentioned TLD monitoring packets.

The ionizatio:. chamber dosimeters are read every month and are used as backup monitors for each station.

For the July 1, 1984 through June 30, 1985 reporting period, an additional onsite envire.nmental radiation monitoring effort was continued.

This effort involved the monthly measurement of the direct gamma radiation exposure rate in terms of microroentgens per hour (pR/hr) at each reactor fence monitoring station. Measure-ments were taken with an Eberline Instrument Company micro-R per hour rate meter containing a 1" x 1" Nal detector.

The monthly readings (normally 12 annually) were then averaged and ultimately converted to an expected (calculated) annual gamma dose equivalent (in mrem) for each location.

(See footnote 6 to Table 5.7).

In terms of environmental radiation monitoring, the onsite area monitoring composite dosimeters, the reactor fence (onsite)

TLDs and integrating ionization chambers, and the direct radiation exposure rate measurements at appropriate locations around the reactor fence can be used to estimate maximum potential radiation doses in nearby unrestricted areas.

Normally, these estimates are made to reflect the annual radiation dose equivalent which could be delivered in the unrestricted area assuming continuous occupancy, although occupancy of unrestricted areas adjacent to the reactor facility is virtually zero throughout the year.

The routine onsite determination of the total radioactivity in liquid effluents (with isotopic identification as appropriate) prior to discharging the liquids into the unrestricted area (the sanitary sewer system) allows a conservative estimate to be made of the magnitude of the reactor facility contribution to potential environmental radiation exposures to the general public from this source.

2.

The Offsite Environmental Radiation Monitoring Program The of fsite environmental radiation monitoring program col-lectively includes a routine soil, water, and vegetation monitoring program, and an airborne gamma radiation monitoring program.

g

5-18 The soil, water, and vegetation monitoring effort centers around the collection of a limited number of samples in each category on a quarterly basis.

It is conducted to monitor both the TRIGA reactor facility and the OSU Radiation Center, and is considered useful for indicating the general trend of the radioactivity coacen-tration in each of the various substances sampled.

See Figure 5.3 for the locations of the sampling stations for grass (G),

soil (S), water (W), and rainwater (RW) samples.

The airborne gamma radiation environmental monitoring program is generally described on pages 4-59 and 4-60 of the August 1968 Safety Analysis Report for the OSU TRIGA Reactor. As of January 1, 1975, nine additional offsite airborne gamma monitoring stations were put into service, to increase the total number of these stations now in use to 19.

See Figure 5.3 for the locations of the 19 airborne gamma radiation monitoring stations, each designated as a TE location on the figure.

As of January 1, 1975, the coding technique used to designate each specific offsite airborne gamma radiation monitoring station was modified slightly to indicate the radiation monitoring devices present at a particular station.

Under the new coding system, stations which contain only a standard OSU TLD monitoring pack (described previously in this report) will have an "L" after the station number.

For example, MRCTE-2L is interpreted as M_onitor Radiation Center TRIGA Environmental Station Number 2, with a standard OSU TLD pack in a copper tube being the only monitoring device at this station.

(NOTE:

The copper tube outer container is still used for all OSU TLD packs employed in the offsite environmental monitoring program.

They were discontinued only for the OSU TLDs used on the reactor area fence). At offsite stations where only an OSU TLD monitor is used, the copper tube containing the TLDs is taped directly onto a mounting post or other permanent object used to identify the monitoring station.

Stations which have n_o_ "L" after the station number consist of a thin weather-tight aluminum box mounted on a post about four feet off the ground.

For the 1984-85 reporting period, each of these stations contained one R.D. Co. TLD pack, one standard OSU copper tube TLD monitoring

i 5-19 pack identical to those previously described, and two 0-200 mrem gamma-sensitive integrating ionization chambers (self-reading pocket dosimeter type) as backup monitors. At these stations, the OSU TLDs were not enclosed inside the aluminum box, but instead the copper tube was taped directly onto the box mounting post at the station. All TLD monitors in the offsite airborne gamma radiation environmental monitoring program were exchanged on a quarterly interval.

The ionization chambers (dosimeters) were read once every month throughout the year.

For the July 1, 1984 through June 30, 1985 reporting period, the previously described effort involving monthly onsite measurements of the direct gamma radiation exposure rate in pR/hr at each reactor fence monitoring station was extended for another year to include each of the 19 offsite airborne gamma radiation monitoring stations.

The data were handled as described in Footnote (7) to Table 5.9, and the objective was to derive an expected (calculated) annual gamma dose equivalent (in mrem) for each monitoring location, based on an annual average pR/hr exposure rate.

3.

An Annual Summary of Onsite and Offsite Environmental Radiation Monitoring Results A summary of the environmental radiation monitoring results for the year July 1, 1984 through June 30, 1985 is given below.

As appropriate for the measurement under consideration, the results include:

a.

The number of sampling locations; b.

The total number of samples per year; c.

The annual average concentration of total radioactivity, and in some cases, concentrations of specific radionuclides in the substance being assayed; and d.

The total annual millirem of external radiation dose for a particular location, as well as a general description of that location.

The data from the onsite and offsite environmental radiation monitoring programs will be presented under headings which correspond to the specific individual program components. These components were identified previously in conjunction with a description of the onsite and offsite environmental radiation monitoring programs.

5-20 a.

Reactor Facility Stack Monitor (0nsite)

1) The system has one sampling location as indicated previously.
2) Samples are continuous (i.e., prior to, during, and af ter reactor operation).

It is normal for the stack monitor to begin operation as one of the first systems in the morning and to cease operation as one of the last systems at the end of a normal operating day.

3) The annual average concentration of gross radioactivity based on the facility stack monitor is given in Table 5.2.

As indicated in this table, the only gaseous component identified has been argon-41, and only naturally occurring particulate radioactivity (radon daughter products) has been detected by the particulate channel.

During the reporting period, the normal concentration for the naturally occurring particulate daughters of radon remained about the same as in previous years, and was within a range of 1.38 x 10-9 pCi/cc to 3.22 x 10-11 pCi/cc.

b.

Reactor Facility Area Monitoring Composite Dosimeters, Reactor Fence TLDs and Integrating Ionization Chambers, and Direct Radiation Measurements (0nsite)

1) There were eight applicable area monitoring composite dosimeters within the TRIGA reactor facility operating area.

There were also nine R.D. Co. supplied CaSO4 TLD monitoring packs, nine standard OSU TLD monitoring packs, and 18 (two per station) 0-200 mrem gamma-sensitive integrating ionization chambers on the reactor area fence. There were also nine specific locations (the fence monitoring stations) where routine monthly pR/hr measurements were made. All of these have application as onsite environmental radiation monitors.

2) Since the beta-gamma sensitive component (i.e., film) in each composite dosimeter within the TRIGA facility was changed once per month, there was a total of 96 different samples of this type during the reporting period.

Since the neutron sensitive component in this dosimeter package was changed quarterly, there was a total of 32 different

5-21 samples of this type.

Quarterly changes of the fence TLD monitors resulted in another 72 R.D. Co. supplied TLD samples (9 stations x 2 CaSO4 TLD monitors per station x 4 changes per year = 72 samples), and 108 OSU TLD samples (9 stations x 3 TLD chips per station x 4 changes per year = 108 samples) for these locations for the reporting period.

The 18 integrating ionization chambers were read once every month and thus resulted in approximately 216 samples (readings) for the reporting period.

There are normally a total of 12 R/hr measurements made at each of the nine fence monitoring stations during the year for a total of approximately 108 such measurements in the reporting period.

3) TRIGA operating area sampling locations are identified in Figure 5.1, with composite dosimeters being located on the inside of the indicated walls at approximately head height above the floor.

Locations of the dosimeter packets are coded Monitor Radiation Center TRIGA North badge, E_ast wall (MRCTNE) and so on.

Locations for the TRIGA operating area composite dosimeters plus locations of the radiation monitors on the reactor area fence are shown in Figure 5.2.

Fence monitoring locations are coded Monitor Radiation Center Fence Environmental, location

_1_ (MRCFE-1) and so on thrcugh MRCFE-9.

TLD monitors on the fence are in sealed moisture-resistant packages inside thin sheet metal mailboxes about four feet off the ground.

The integrating ionization chambers are also contained in the metal boxes. Annual radiation dose equivalent totals for the onsite area monitoring locations are given in Tables 5.6 and 5.7.

c.

Analysis of Reactor Contributed Radioactivity in Liquid Effluents (0nsite)

1) TRIGA liquid effluent is analyzed at the time it is releascJ to a collection point (a holdup tank), and is analyzed again in conjunction with other radioactivity from the

5-22 Radiation Center, which also may be present in the holdup tank prior to discharge from this collection point into the unrestricted area (the sanitary sewer system).

2) The total number of samples were as follows:

two reactor liquid effluent samples for the period July 1,1984 through June 30, 1985, in conjunction with two separate releases of reactor liquid effluent into the holdup tank collection point; and one liquid effluent sample from the holdup tank for the period July 1,1984 through June 30, 1985 before the single release of the liquid effluent in the holdup tank collection point to the unrestricted area (the sanitary sewer).

3) The liquid effluent data for environmental assessment have been summarized for the reporting period in Table 5.1.

Section 5.E.2 of this report also addresses the virtually undetectable level of direct radiation from this liquid and the negligible potential dose commitment in the unrestricted area from the radioactivity in this liquid effluent.

d.

Soil, Water, and Vegetation Monitoring (Offsite)

1) For this environmental manitoring effort there are now a total of 22 sampling locations; four soil locations, four water locations (when water is available), and 14 vegetation locations.
2) Samples (as available) are taken at each location on a quarterly basis. Samples have been collected as follows for the period July 1, 1984 through June 30, 1985:

Total number of samples 84 Total number of soil samples 16 Total number of water samples 12*

Total number of vegetation samples 56

  • (Durii.g the reporting period there were four instan:es when a collection point was dry).
3) The annual average concentration of total net beta radioactivity (minus 3 ) for samples collected at each offsite environmental H

soil, water, and vegetation sampling location (sampling l

l l

5-23 station) is given in Table 5.8.

Identification of specific radionuclides is not routinely carried out as part of this program, but would be conducted if unusual radioactivity levels above natural background were evident.

Locations of sampling points relative to the reactor facility are given in Figure 5.3, and as shown in this figure, most locations are within a 1,000-foot radius of the reactor building and the Radiation Center.

In general, samples are collected over a local area having a radius of about ten feet at the positions indicated in Figure 5.3.

e.

Airborne Gamma Radiation Monitoring (Offsite)

1) The offsite airborne gamma environmental radiation monitoring program currently utilizes 19 stations, and each station is considered a sampling location.

For the 1984-85 reporting period, 11 stations had an R.D. Co. supplied CaSO4 TLD monitoring packet, a standard OSU TLD monitoring pack, and two 0-200 mrem gamma pocket dosimeters. Eight stations had only a standard OSU TLD monitoring pack.

In addition, each of the 19 monitoring stations were included in the ongoing program for measurement of the pR/hr exposure rate.

2) The TLDs at each airborne gamma monitoring station were changed once every calendar quarter resulting in a total of 88 R.D. Co. TLD samples during the 1984-85 reporting year (11 stations x 2 CaSO4 monitors per station x 4 changes per year = 88 samples), and a total of 231 OSU TLD samples during the same period (18 stations x 3 TLD chips per station x 4 changes per year = 216 samples [minus 1 TLD dosimeter containing 3 chips for a one quarter interval, due to theft during the current reporting period], plus 1 station with 6 TLD chips x 4 changes per year = 24 samples [minus 1 TLD dosimeter containing 6 chips for a one quarter interval due to theft during the current reporting period] for a final total of 231 OSU samples for the

5-24 current year). The two backup monitors (integrating ionization chamber dosimeters) were read every month, which resulted in approximately 264 individual dosimeter readings for the reporting period.

There are normally a total of 12 pR/hr measurements made at each of the 19 airborne gamma radiation monitoring stations each year for a total of approximately 228 individual measure-ments of this type annually.

3) locations of the 19 airborne gamma radiation monitoring stations are shown in Figure 5.3.

Like the soil, water, and vegetation sampling locations, most of the airborne gamma monitoring stations are within a 1,000-foot radius of the reactor building.

These locations generally correspond to distances of interest with respect to the atmospheric (plume) dispersion results mentioned earlier in this report.

The dosimetry data from the airborne gamma radiation monitoring stations are summarized in Table 5.9,. and are based on the vendor-supplied TLD data, the OSU TLD data, and results obtained from the pR/hr measurements.

See Footnote (7) of Table 5.9 for a further explanation of the pR/hr data and its application.

The OSU in-house TLD program was started in 1974, and we believe a number of improvements have been made in the program since that time. There are, however, a few aspects which we continue to work on and some which may still require added refinement.

In particular, we are continuing to study our background for the airborne gamma monitoring stations, because we feel that our reported average natural background value is occasionally lower than the natural background some stations are actually experiencing.

We increased the number of background stations during 1976, and between July 1, 1984 and June 30, 1985 we continued to make a series of direct background measurements with our pR/hr monitoring equipment (started July 1, 1977) in order to obtain a better profile of the background variation. We plan to continue our surveillance of this variable.

1 5-25 From our viewpoint, the major purpose of the airborne gamma radiation monitoring stations is to give an indication of general increases or trends in unrestricted area radiation levels which might be linked to argon-41 released from the OSU TRIGA reactor.

Past experience (over the last 15 years) has shown that annual results per location vary slightly from year to year. Although the data have not been included in this report, by following the mrem per year history for any single station and comparing the annual mrem total for that station to the curies of argon-41 i

emitted for the corresponding year, it becomes evident that there is no consistent correlation or pattern to the results and that other factors must be responsible for the minor mrem per year variations at the stations.

For example, such variations may be the result of small, annual differences in cosmic or terrestrial background radiation, fallout, etc.

In any event, the amount of argon-41 released annually (particularly in view of the very low concentrations involved and the significant decreases registered over the past three to four years) does not seem to be a significant factor which effects the total mrem per year measured (or predicted from pR/hr readings) for any particular monitoring station. A comparison of the data contained in Table 5.9 to past results from these monitoring stations, and a comparison to the values in Footnote (7) of Table 5.9, leads us to the firm conclusion that there has been no detectable or meaningful increase in the unrestricted area gamma radiation levels due to the very low concentrations of short-lived argon-41 released i

by the OSU TRIGA reactor during the defineo reporting period.

t g

5

5-26 6.

REFERENCES ~

'1.

Eisenbud, Merril, Environmental Radioactivity, Second Edition,

p. 190, Academic Press, New York, NY (1973).

2.

U.S. Environmental Protection Agency, " Estimates of, Ionizing Radiation Doses in the United States, 1960-2000," ORP/CSD 72-1, Office of Radiation Programs, Rockville, Maryland (1972).

3.

U.S. Environmental Protection Agency " Radiological Quality of the Environment in the United States,1977," EPA 520/1-77-009, Office of Radiation Programs; Washington, D.C. 20460 (1977).

Table 5.1 j

Monthly Summary cf Liquid Waste Discharges For the Y1ar July 1.1984 through June 30,1985(I)

Date of Total Quantity of Detectable Specific Activity for Total Curies of Average Concentration Percent of Total Volume of Discharge Ratioactivity Radionuclides Each Detectable Radio-Each Detectable of Released Applicable Liquid Effluent.

(Month Released in the Waste nuclide in the Waste Radionucifde Radioactive Material MPC for Including Diluent,

& Year)

(To Sanitary Sewer)

-Discharged. Where the Released in the at the Point of Release Released Released (Curles)

Released Concentration Waste (To the Sanitary Sewer)

Radioactive (To Sanftary Sewer)

AfterDilujionWas (Curies)

(pC1/cc)

Material (Gallons)

>1.0 x 10- pC1/cc (1)

(pC1/cc)

JUL 84 Mone None Not Applicable None Not Appitcable Not Applicable None AUG 84 None None Not Applicable None Not Applicable Not Applicable None SEP 84 None None Not Applicable None Not Applicable Not Appitcable None OCT 84 None None Not Applicable None Not Applicable Not Applicable None l

NOV 84 None None Not Applicable None Not Applicable Not Applicable None DEC 84 None None Not Applicable None Not Applicable Not Applicable None JAN 85 None None Not Applicable None Not Applicable Not App 1fcable None FEB 85 6.50x10-5 3H 7.26x10-6 6.50x10-5 7.26x10-6 0.25% (2) 2366 E

1.76x10-8 0.0075%(3) 15? u 1.42x10-8 60 o C

NAR 85 None None Not Applicable None Not Applicable Not Applicable None APR 85 None None Not Applicable Hone Not Applicable Not Applicable None MAY 85 None None Not Applicable None Not Applicable Not Applicable None JUN 85

.None None Not Applicable None Not Appifcable Not Applicable None ANNUAL 0.25% (2)

TOTAL 6.50x10-5 See Above Not Applicable 6.50x10-5 7.26x10-6 0.0075%(3) 2366(4)

(1) The OSU operational policy is to subtract only detector background from our water analysis data and not background radioactivity in the Corvallis city water.

(2) Based on values listed in 10 CFR 20. Appendix 2. Table 2. Column 2.

(3) Based on values listed in 10 CFR 20. Appendix 8. Table 1. Column 2, which are applicable to sewer disposal.

(4) The total volume of ifquid effluent plus diluent does not take into consideration the additional mixing with approximately 95,000 to 115,000 gallons per year of liquids and sewage nonna11y discharged by the Radiation Center complex f nto the same sanitary sewer system.

Y ts

Table 5.2 Monthly Summary if Gassous Wasta Discharges for the Y4ar July 1. 1984 through Jt.13 30, 1985 i

Date of Total Total Estimated Average Percent of the Total Estimated Average Estimated Average Percent of Discharge Estimated Estimated Atmospheric Applicable Quantity of Concentration Concentration of MPC if the (Month & Year)

Radioactivity Quantity of Diluted MPC for D11utes!

Radioactivity in of Ra(ioactive Other Significant Estimated Released Argon-4 Concentra tion Concentration Particulate Form Particulates Radionuclices in Release was (Curles)

Released 1)

Argon-41 a of Argon-41 at withHalf-gives Released With Discharge if

>20% of the (Curles)

Point of Release Point of Release

>8 Dayst )

Half-Lives >8 Days

>20% of the Applicable (Reactor Stack)

(Reactor Stack)

(Curies)

(Curies) fpp11 cable MPC MPC (pC1/cc)

(1)

(pC1/cc)

JUL 84 0.63 0.68 4.85 x 10-8 1.21 None Not Applicable Not Appilcable Not Applicable AUG 84 81.83 0.83 5.92 x 10-8 1.48 None Not Applicable Not Applicable Not Applicable SEP 84 0.98 0.98 7.20 x 10-8 1.80 None Not Applicable Not Applicable Not Applicable OCT 84 0.94 0.94 6.68 x 10-8 1.67 None Not Applicatie Not Applicable Not Applicable NOV 84 0.96 0.96 7.09 x 10-8 1.77 None Not Applicable Not Applicable Not Applicable DEC 84 0.87 0.87 6.22 x 10-8 1.56 None Not Applicable Not applicable Not Applicable JAN 85 1.06 1.06 7.57 x 10-8 1.89 None Not Applicable Not Applicable Not Applicable FE8 85 0.57 0.57 4.52 x 10-8 1.13 None Not Applicable Not Applicable Not Applicable MAR 85 0.58 0.58 4.16 x 10-8 1.04 None Not Applicable Not Applicable Not Applicable APR 85 0.63 0.63 4.66 x 10-8 1.17 None Not Applicable Not Applicable Not Applicable MAY 85 0.53 0.53 3.86 x 10-8 0.97 None Not Applicable Not Applicable Not Applicable JUN 85 0.78 0.78 5.71 x 10-8 1.43 None Not Applicable Not Applicable Not Applicable ANNUAL VALUE 9.41(3) 9.41(3) 5.70 x 10-6 1.43 None Not Applicable Not Applicable Not Applicable 4

(1) Routine gama spectroscopy analysis of the gaseous radioactivity in the stack discharge indicated that it was virtually all argon-41.

(2) Evaluation of the detectable particulate radioactivity in the stack discharge confirmed its origin as naturally-occurring radon daughter products, predominantly lead-214 and bismuth-214. which are not associated with reactor operations.

(3) The 25.7% decrease in total argon-41 released during the current reporting period is due to several modifications designed to reduce the argon-41 effluent to as-low-as-reasonably-achievable levels. We anticipate that our argon-41 releases will remain at about the 1984-85 level.

4 M

t

i 5-29 Table 5.3 Annual Summary of Solid Waste Discharges For the Year July 1, 1984 through June 30, 1985 Total Amount Detectable Total Quantity Dates of Shipment of Solid Waste Radionuclides of Radioactivity and Disposition (1)(2)

Packaged in the Waste in Solid Waste (Cubic Feet)

(Curies) 24 Sodium 51 Chromium 54 Manganese 58 obalt C

59 ron 9.46x10-4 December 5, 1984 11.0 I

60 obalt C

65 Zinc 75 elenium S

124 ntimony A

140 anthanum L

(1) 0STR solid radioactive waste is routinely transferred onsite (within the Radiation Center building) to the OSU Radiation Safety Committee, where it is held on the University's State of Oregon radioactive materials license, along with other campus waste, prior to shipment to U.S. Ecology.

(2) All solid radioactive waste is transferred by the University Radiation Safety Committee to our radioactive waste disposal service vendor, the U.S. Ecology Company, for burial at their installation located near Richland, Washington.

\\

~

Table 5.4 Annual Summary of Radiation Exposure Received By Facility Personnel and Visitors for the Year July 1, 1984 through June 30, 1985 Average Annual Exposure Greatest Individual for Each Personnel Group Exposure per Personnel Group Personnel Group Whole Body Extremities Whole Body Extremities (mrem)

(mrem)

(mrem)

(mrem)

Facility Operating Personnel 64.00(1) 111.00 380.00(1) 1090.00 Kay Facility Research Personnel 1.00 2.00 25.00 70.00 Facility Visitors:

Film Badges /TLDs (2)

(2)

(2)

(2)

Pocket Dosimeters

<1.00 N/A(3) 10.00 N/A(3)

(1) The increased whole body exposure for the facility operating personnel during the 1984-85 reporting period can be j

attributed to the one-time search for a possible leaking TRIGA fuel element in January and February of 1985.

(2) OSU TRIGA reactor policy does not normally allow people in the visitor category to become actively involved in the 4

use or handling of radioactive materials.

Therefore, visitor whole-body film badges and extremity TLDs are not normally necessary, and no visitor data are available in these categories.

T (3) Not applicable.

8 4

i i

5-31 Table 5.5 Annual Summary of Radiation Levels and Contamination Levels Observed Within the Reactor Facility During Routine Radiation Surveys For the Year July 1, 1984 through June 30, 1985 Accessible Whole Body Radiation Levels Contamination Levels locations (nrem/hr)(sy+ neutrons)

(dpm/100 cm2)(6Y)(l)

Average Maximum Average Maximm R

or cility Reactor Top 5.70 160.00

<500(2) 3600(2)

General Reactor

<1.00 10.00

<500

<500 Room Area Beam Port Facilities (Reactor Room,

<1.00 22.00

<500

<500 First Floor)

Sample Handling Area (Reactor Room,

<1.00 12.00

<500

<500 First Floor)

Demineralizer Tank-Outside Shield

<1.00 8.00

<500

<500 (Reactor Room, First Floor)

Class Experiments 1.50 37.00

<500

<500 (1) No contamination equal to or above the specified 500 dpm/100 cm2 reporting limit was found during the entire reporting period at locations designated <500.

The <500 dpm/100 cm2 value used in this table was based on a consideration of the radionuclides likely to be present in any contamination detected, on the normal beta counting efficiency for such radionuclides when using the radiation survey instruments routinely employed at the OSTR to measure contamination in the field, and on a radiation survey result which showed the net counting rate to be less than the background counting rate, provided the background counting rate was <100 cpm (i.e., field contamination measurements would normally have to show a gross counting rate equal to at least twice the background counting rate, but generally never greater than 200 gross cpm, before contamination would be considered present).

However, in addition to normal field screening for contamination by direct surveys and smear samples, smears of particular importance or interest and any smears otherwise suspected of containing removable radioactive contamination were routinely counted in a more sensitive radiation detection system.

Based on usual counting times, a normal instrument counting efficiency, and a typical background counting rate, such a detection system generally showed a lower limit of detection (LLD) at 95% confidence of approximately 15 dpm for the radionuclides normally expected to be on smears if contamination was present.

As a matter of initial conservatism, smearing efficiency for radioactivity removal is routinely assumed to be <100%.

If warranted, after assessing each situation, nositive smear results are multiplied by a factor to correct for smearing efficiency before final conversion to dpm/100 cm2, (2) The contamination shown for this location was a unique one-time situation and was removed immediately. As a result, during the reporting period the average contamination level on the reactor top was, for all practical purposes, <500 dpm per 100 cm2,

5-32 Table 5.6 Total Dose Equivalent Recorded on Operating Area Composite Dosimeters Located Inside the TRIGA Reactor Facility for the Year July 1, 1984 through June 30, 1985 Total Recorded mrem for the Year Location (l)

July 1, 1984 through June 30,1985(2)(3)(4)

MRCTNE 15(7)

MRCTSE

<10(5)

MRCTSW 15 MRCTNW

<10 MRCTWN

<10 MRCTEN 30(7)

MRCTHXS

<10(6)

MRCTHXW

<10 (1) These locations do not represent radiation exposure through an exterior wall directly into an unrestricted area.

(2) Totals do not include natural background contribution.

(3) The beta-gamma dosimeter in each of the above composite dosimeters was exchanged on a monthly basis, while the neutron dosimetry packet was exchanged on a quarterly frequency.

(4) The total millirem values. listed above are entirely due to gamma radiation, and reflect the summation ~of results from 12 different beta-gamma dosimeters for each location.

Those listed at <10 mrem showed twelve separate readings below the vendor's gamma dose reporting threshold of 10 mrem. All July 1984 through June 1985 quarterly fast neutron doses were below R.D. Co.'s fast neutron detection threshold of 30 mrem.

(5) This is the composite dosimeter opposite the subcritical pile.

This dosimeter primarily monitors the subcritical pile and the effectiveness of the subcritical pile shield.

It is, therefore, somewhat shielded from other reactor room activities.

The shield for the subcritical pile was completed February 23, 1972. The total mrem reported for this location reflects an annual total below the neutron and gamma dose detection thresholds listed in footnoteL(4).

~,-

w

5-33 Table 5.6 (continued)

(6) This is the composite _ dosimeter opposite the particulate filter for the reactor primary water cleanup system. A shield around this filter was completed July 10, 1972, and the annual dose equivalent totals from this operating area composite dosimeter are below the neutron and gamma dose detection thresholds listed in footnote (4).

(7) These dose equivalent totals are attributed to the short term use of small gamma-emitting sealed sources inside the reactor bay for laboratory classes in nuclear engineering and radiation protection.

3 9-

Tabla 5.7 Total Dosa Equivaltnt at the TRIGA Reacttr Arsa Ftnce For ths VIar July 1,1984 thrcugh Juna 30, 1985 Total Calculated erem Total Recorded mrem Total Recorded mrem

. for the Year for the Year for the Year July 1, 1984 July 1. 1984 July 1. 1984 through Fence Locstion

-through

. through June 30. 1985 (1)

June 30. 1985 June 30. 1985 Based on the Annual Average Based on R.D. Co. TLDs Based on OSU TLDs R/hr Exposure Rate

.(2)(3)

(3)(4)(5)

Measured at Each Location (5)(6)

MRCFE-1 113.8 75.8 2 10.6 71.8 2 35.3 MRCFE-2 118.5 64.0 1 31.3 79.5 2 28.3 62.9 2 8.6 71.9

  • 31.3 MRCFE-3 118.5(7) 100.4 t 30.4(7) 79.5240.4 MRCFE-4 128.l MRCFE-5 112.8 76.3 1 10.9 69.0 1 33.1 MRCFE-6 113.8 76.3 2 13.8 71.5 2 44.0 MRCFE-7 113.8 69.3 2 15.7 68.0 1 24.7 MRCFE-8 110.9 69.8 2 8.6 64.2 2 25.7 MRCFE-9 112.8 70.8 1 9.2 63.5 2 31.6 (1) The TRIGA reactor area fence was installed September 15, 1972.

(2) Radiation Detection Company (R.D. Co.). Sunnyvale, California. TLD totals include their annual natural background 4

contribution of 91.8 mrem for the reporting period. Average Corvallis area natural background using R.D. Co.

TLDs totals 100.4 mrem for the same period.

}

(3) TLD monitoring packets are exchanged on a quarterly interval.

(4) OSU fen g)TLD totals include a measured annual natural background contribution of 63.4 2 6.0 mrem for the reporting period. P (5) i values represent the standard deviation of the total value at the 95% confidence level.

(6) The annual average microroentgen (pR) per hour exposure rate for each location is normally determined by averaging 12 separate pR/hr measurements taken at monthly intervals throughout the year. The total mrem for the period is then calculated by multiplying this average pR/hr value by 8760 hours0.101 days <br />2.433 hours <br />0.0145 weeks <br />0.00333 months <br /> per year and then by converting micro-roentgens to millirem. Normal pR/hr values for the U.S. (terrestrial plus cosmic radiation) range between about 7.0 and 11.0 pR/hr (Ref.1) (excluding areas of unusually high natural radioactivity). These exposure rates correspond i

to annual dose equivalent totals of about 59 to 93 mres per year. The U.S. EPA (Ref. 2,3) estimates the total annual terrestrial plus cosmic dose equivalent for Oregon to be about 110 arem per year.

(7) A possible slight increase in the dose equivalent recorded by this station is not believed to be related to reactor operations, but instead is attributed to the same short tenu use of seaTT gamma-emitting sealed sources

. Inside the reactor bay for laboratory classes in nuclear engineering and radiation protection as mentioned in footnote (7) of Table 5.6.

Monitoring station FE-4 views that portion of the reactor building which includes the steel equipment access doors, and as expected, the attenuation provided by these doors is not quite equal to that provided by the building's concrete walls.

Y w

4' 6

~

. ~. --

5-35 Table 5.8 Annual Average Concer.tration of the Total Net Beta Radioactivity (Minus 3 )

H For Offsite Environmental Soil, Water, and Vegetation Samples For the. Year July 1, 1984 through June 30, 1985 Sample Location Identification Annual Average Concentration of Total Net Number, Type & Reporting Units Beta Radioactivity (Minus 3 )(1)(2)(3)(4)

H 1-water (pCi/cc) 3.40 x 10-8 5.19 x 10-10 (5) 4-water (pCi/cc) 3.41 x 10-8 2 5.54 x 10-10 (6) 11-water (pCi/cc)-

3.39 x 10-8 1 1.85 x 10-9 19-rainwater (pCi/cc) 3.42 x 10-8 1 1.74 x 10-9 (5) 3-soil pCi 4.98 x 10-5 3.60 x 10-5 j

(gram of dry soil) 5-soil pCi 4.55 x 10-5 3.07 x 10-5 1

(gram of dry soil) pCi 7.31 x 10-5 1 1.30 x 10-5 i

20-soil (gram of dry soil) 21-soil pCi 7.18 x 10-5 1 1.52 x 10-5 l

(gram of dry soil) pCi 3.09 x 10-4 2.71 x 10-4 2-grass (gram of dry ash-)

uCi 2.73 x 10-4 2.33 x 10-4 6-grass (gram of dry ash )

pCi 3.21 x-10-4

  • 5.21 x 10 7-grass (gram of dry ash )

pCi 2.81 x 10-4 2 2.30 x 10-4 8-grass (gram of dry ash )

pCi 2.76 x 10-4 1 3.64 x 10-4 9-grass (gram of dry ash )

pCi 2.71 x 10-4 1.94 x 10-4 10-grass (gram of dry ash )

pCi 3.37 x 10-4 1 2.27 x 10-4 12-grass (gram of dry ash )

uC1 3.78 x 10-4 1 9.46 x 10-5 13-grass-(gram or cry asn. )

5-36 Table 5.8 (continued)

Sample Location Identification Annual Average Concentration of Total Net Number, Type & Reporting Units Beta Radioactivity (Minus 3 )(1)(2)(3)(4)

H pCi 2.33 x 10-4 2.50 x 10-4 14-grass (gram of dry ash) pCi 2.43,x 10-4 1.52 x 10-4 15-grass

(_ gram of dry ash) pCi 3.09 x 10-4 1 1.90 x 10-4 16-grass

(_ gram of dr;' ash) pCi 3.25 x 10-4 2.34 x 10-4 17-grass (gram of dry ash) pCi 3.47 x 10-4 2.47 x 10-4 18-grass (gram of dry ash) pCi 3.67 x 10-4 2.29 x 10-4 22-grass f' gram of dry ash)

(1) " " values represent the standard deviation of the average value at the 95% confidence level.

(2) Annual average concentrations were calculated using sample results whk.h exceeded the lower limit of detection (LLD), except that sample results which were f_ the LLD were averaged in at the corresponding LLD concentration.

(3) For this report, the lower limit of detection (LLD) has been defined as the smallest amount or concentration of radioactive material (in terms of pCi per unit volume or unit mass) in a representative sample, which has a 95% probability of being detected.

It is equivalent to 4.66 times the standard deviation of the detection system's background counting rate obtained with a blank sample (provided the relative standard deviation of the background rate, the coefficient of variation, is less than 25%) and is expressed in pCi divided by the typical volume or mass of the sample type involved.

For the year July 1, 1984 through June 30 1985, the LLD for total net 8 in water samples averaged 3.39 x 10-8,pCi/cc and ranged between 3.52 x 10-8 pC1/cc and 3.29 x 10-8 pCi/cc.

For total net 8 in vegetation samples, the LLD averaged 2.00 x 10-5 pCi/gm of dry ash, and ranged between 2.39 x 10-5 pCi/gm of dry ash and 1.88 x 10-b pCi/gm of dry ash.

For total net 8 in soil samples, the LLD averaged 1.34 x 10-5 Ci/gm of dry soil, and ranged between 1.54 x 10-5 pCi/gm of dry soil and 1.26 x 10-5 Ci/gm of dry soil.

The preceding LLD values for net activity in water, vegetation, and soil samples exclude 3.B radio-H

5-37 Table 5.8 (continued)

(4) The total net beta radioactivity is based on the total net beta dis-3 Calculation of the total integration rate per sample, excluding H

net beta disintegration rate incorporates subtraction of only the counting system background from the gross beta counting rate, followed This value (the total net beta radioactivity)g system yield (or efficiency).

by application of an appropriate beta countin is also sometimes implied (but not in this report) by use of the term gross beta radioactivity, usually when the beta' background is a small fraction of the gross beta counting rate.

(5) Results are based on three quarterly samples. The indicated collection point was dry during one collection period.

(6) Results are based on two quarterly samples. The indicated collection point was dry during two collection periods.

l l

2 i

l i

1

~..

~

.~

5-38 Table 5.9 Total Dose Equivalent at the Offsite Airborne Gama Monitoring Stations For the Year July 1.1984 through June 30, 1985 Total Calculated mrem Total Recorded mrem Total Recorded mrem for the Year for the Year for the Year July 1. 1984 i

Monitoring July 1. 1984 July 1.1984 through Station through through June 30. 1985 (1)(2)

June 30, 1985 June 30, 1985 Based on the Annual Average Based on R.D. Co. TLDs 8ased on Standard OSU TL0s pR/hr Exposure Rate (3) (4)

(4)(5)(6)(8)

Measured at Each Location (6) (7) 57.0 t 14.4 51.6 t 19.8 MRCTE-2L MRCTE-3 120.5 68.6 2 6.8 77.5 2 33.3 MRCTE-4 116.6 61.2 2 5.3 71.1 2 27.7 60.6

  • 5.7 71.1 2 24.5 MRCTE-5L MRCTE-6 119.5 75.3 t 36.2 81.3 2 25.5 59.6
  • 13.5 72.9
  • 23.9 l

MRCTE-7L NRCTE-8 131.0 66.5 2 18.2 83.3 t 35.7 i

MRCTE-9 125.2 68.7 2 17.4 81.3 2 38.4 MRCTE-10 110.9 65.2 12.1 62.8

  • 28.4 i

MRCTE-11 105.2 68.4 2 8.3(8) 60.0

  • 16.9 MRCTE-12 126.2 69.6 2 8.3 80.9 2 32.3 MRCTE-13L 59.5 2 6.4 74.6 2 23.4 l

MRCTE-14L 62.8 2 14.7 57.9 2 22.6 i

MRCTE-15 111.9

'57.6 2 12.1 77.5 2 54.5 I

MRCTE-16L 58.6 i 9.0 (8) 73.9 2 34.8 MRCTE-17 113.8 63.9 2 20.6 66.9 2 31.6 67.7 2 14.9 71.1 2 27.5 MRCTE-18L 4

MRCTE-19 124.3 62.0 2 21.0 81.3 2 21.4 MRCTE-20L 71.7 2 10.2 66.9 2 30.7 (1) Monitoring stations coded with an "L" contained one standard OSU TLD monitoring pack only (no R.D. Co. TLD pack).

(2) Monitoring stations not coded with an "L" contained one R.D. Co. TLD mor.:*oring pack, two 0-200 mrem gamma pocket dosimeters, ard one standard OSU TLD monitoring pack.

4 (3) Radiation Detection Coogany (R.D. Co.). Sunnyvale. California. TLD totals include their annual natural background i

contribution of 96.6 mrem for the reporting period. Average Corvallis area natural background using R.D. Co.

TLDs totals 100.4 mree for the same period.

(4) TLD monitoring packets are exchanged on a quarterly interval.

(5) OSUoffsiteairbornegammaTLD(gqtalsincludeameasuredannualnaturalbackgroundcontributionof64.3*8.3 4 -

mrem for the reporting period. i (6)

"1" values represent the standard deviation of the total value at the 951 confidence level, i

(7) The annual average microroentgen (pR) per hour exposure rate for each location is normally determined by averaging 12 separate pR/hr measurements taken at monthly intervals throughout the year. The total mrem for the period 4

is then calculated by multiplying this average pR/hr value by 8760 hours0.101 days <br />2.433 hours <br />0.0145 weeks <br />0.00333 months <br /> per year and then by converting micro-roentgens to millf rem. ' Normal pR/hr values for the U.S. (terrestrial plus cosmic radiation) range between about i

7.0 and 11.0 pR/hr (Ref.1) (excluding areas of unusually high natural radioactivity). These exaosure rates correspond to annual dose equivalent totals of about 59 to 93 mrem per year. The U.S. EPA (Ref. 2.3) estimates the total annual terrestrial plus cosmic dose equivalent for Oregon to be about 110 mrem per year.

(8) Total arem for the reporting period is based on three calendar quarters of measured data, plus a fourth quarter j

of data derived from averaging the three quarters of measured data. These calculations to supplement the measured results were necessary due to lost or stolen TLD monitors in one quarter.

4 4

5-39 Figure 5.1 Operating Area Composite Dosimeter Locations for the TRIGA Reactor Building External Walls I I f~l M

1 3i N,

x MRCTNE MRCTSE N

SUBCRITICAL P!LE REACTOR MRCTEN

.(FIRST FLOOR) i 60' i

TRIGA Reactor l

t

\\

/

MRCTWN

( MRCTNW g MRCTSW

'q

%e

\\

g L.J 3 J'l y

Demin.

L. T A

tank 6 Heat Exchanger O MRCTHIS

  • N-HEAT

/,20 Demineraliser

\\. '

EXCHANGER Pump Platform

goa, MRCTHXW 30'

5-40 Figure 5.2 Area Radiation Monitor Locations for the TRIGA Reactor, and on the TRIGA Reactor Area Fence N=

PERIMETER FENCE 1

MRC FE3 MRC FE2 0FFICE BUILDING

$ MRC FE4 MRC FE19 CC 3

(

MRCTNE MRC TSE

[-

e e

R A DI ATION MR6 TEN g TRIGA REACTOR C E NTER l

BAY l

BUILDIN G I,

MRCTWN S MRCTSW l

9 8

l HX $ MRC THXS j

j MRC TNW/

ROOM l

g MRC THXW

$ MRC FE5 '

]

[

L10UID gps-R. A.WA ST E

(

HOLD UP 1

TANK

)\\

l MRC FE6 k

S l

TRANSFORMER MRCFE96 l

STATION MRCFE7 MRC FE8 l

_a a

koft 0

5_41 a

I II l!

Figure 5.3 l!

L L_

MONITORING STATIONS FOR THE

!1 l_

Orchard C (I] CD OSU TRIGA REACTOR FOR THE YEAR

, Court 0

q" l

I July 1, 1984 TEt3L through

,N i {

p,.

f c; '

C June 30, 1985

, hI 8

,a P

ca,-

.nu u_

7 0

to aono-a.

  • i.

J 0

l!

9 M ' [i n

1 I

-l cr -n 1 m

ol

) f, mt o,. -< E E E Fo.c.. a P, ' rs r i

=esea t_

t is.

6n.,nain ur m

. a,

! iSatt tuscal an._

.r

- _J_Ieu l I,c y y

i c%_

j j l

m TI3 aciuty.

i I *>.'"

$'$:1(

} :'

0 t.-

[1

.i..a,.

]

170 6

[

j

-[$$If

~l> EQ w.m._

82 0s as h ff

',,',[

s Q

t; caa m l

ic. r-r,A m.e!

'~i bl l

'*0'JR r

ny' E

a,,

i 0 "

[

l

] TE5L

-35 a6

_-. y __-_ ___-.......--

e,,

6G 6G FE4

]

l ati res h

sas.Ja.ej/

.,J J

i l

H i

l

,,m a

^ktR TE1Sg

-4.

FT)e ji hr

=n"f./

J

(== r

, i e

a a

DFEB 8

PI(L0$

< t s tess a.

n 2

I ay g=e T

..._____.._________37

- 4 %_a,G __/

F0etst y F0#fS f SCI h"

i AUW$0 aJ

,ta y NALL s'

i g

. {(

r eats TE$9 l

1

\\

[

Y~

)

1d.:3 C FE 2 P

r iso a

k' 8

813G J

[

8 22 3

  • li

{st-g g-I i

enococa 1

u{.,

p n u se tis i

mi n

..gi N

I laf g,C C

~.o;!g (

[

eao.o.en I

P" u

u

,e u

g g'* '

l

,,m' s

PMT$rCab DiaNT U

J 4 nr.c j

eToaar.c anca

' l nti t. tocates at en.

Inbo b

'I(~~'~l U'

\\

Corvallis Airp<,rt, 5 miles

(

..G.aem %

.5 6[

.l I

south of the paliation Center

_ p !. j v (y c

i l

'u==>

gt w

a,,rg,5",=::=,_. -

iWan'!".r' i

car (N10he0LO41

\\

GAsiseART

.f 'l

Catta 0 100 200 300 f't. i/

eia t

i a

resou a

e

_.;,, RECEIVED

(

!!RC Ogn 88J EP 25 FM I: 05 Radiation Center University Corvanis, Oregon 97331

< sos) mmt v

i REGION V's September 15,1985 U.S.. Nuclear Regulatory Commission 3,@3Q Q1498;Marfa' Lane, Suite 210 Walnut Creek, CA 94596-5368 Attention: Regional Administrator Gentlemen:

Reference:

Oregon State University TRIGA Reactor (OSTR), Docket No. 50-243, License No. R-106 In accordance with the requirements specified in the Technical Specifications for the_ Oregon State University TRIGA Reactor, we are submitting to you five copies of the OREGON STATE UNIVERSITY TRIGA REACTOR ANNUAL REPORT for the reporting period July 1,1984 through June 30,1985. In addition, please note that we are using this letter of transmittal to send two copies of the report to the Director of the Office of Inspection and Enforcement in Washington, D.C., plus one copy of the report to Mr. Robert Carter, Division of Licensing, Washington, D.C., and one copy to the USNRC Document Control Desk, Washington, D.C.

As you will observe, the OSTR annua 1 report contains information required by the U.S. Nuclear Regulatory Commission, the U.S. Department of Energy, and the Oregon Department of Energy. Ilowever,if there is any additional information that you desire, we will be most happy to provide it.

Sincerely, r

Cliffor

. Smith, Jr.

Reactor Administrator Director, Radiation Center CVS/ef Enclosure cc w/ enclosure:

Document Control Desk, USNRC, Washington,' D.C. (1 copy)

Standardization and Special Projects Branch, Division of Licensing, USNRC, Washington, D.C., ATTN: Mr. Robert Carter (1 copy)

' Director, Office of Inspection & Enforcement, USNRC, Washington, D.C. (2 copies) g [)

Oregon State University is an Affirmative Action / Equal Opportunity Ernployer

?A

o cc w/out enclosure:

Director, Oregon Department of Energy T.D. Parsons, Vice President for Administration, OSU A.G.' Johnson, Assistant Director, Radiation Center, OSU B. Dodd, OSTR Assistant Reactor Administrator, OSU T.V. Anderson, OSTR Reactor Supervisor, OSUfor the reporting period d

.f

._'