_ _. _ _ _

l 4

ArrACHMENT 1 i

1996 UNIT 2 REFUELING OUTAGE l

INSERVICE INSPECTION

SUMMARY

REPORT i

OWNER'S REPORT FOR INSERVICE INSPECTIONS i

l NORTH ANNA POWER STATION - UNIT 2 P.O. BOX 402 MINERAL, VA 23117 COMMERCIAL SERVICE DATE 12-14-80 i

VIRGINIA ELECTRIC AND POWER COMPANY 2

5000 DOMINION BOULEVARD GLEN ALLEN, VA 23060 97o1140054 970102 gDR ADOCK 05000339 PDR

Dockst Numbers 50-339 Serial Number: 96-629 l FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS age 1 of 20 As required by the Provisions of the ASME Code Rules

"" ^

1. Owner (Name and Address of Owner)

North Anna Power Station, P.O. Box 402, Mineral, VA 23117 p

(Name and Address of Plant)

Unit 2 N/A

3. Plant Um.t
4. Owner Certificate of Authorization (if required)
5. Commercial Service Date 12 14 80
6. National Board Number for Unit N/A
7. Components Inspected Manufacturer Component or Manufacturer or installer State or National Appurtenance or Installer Serial No.

Province No.

Board No, Class 1 Piping -

Southwest Fabricating 301 N/A N/A 109C weld 1 Class 1 Pipirg -

Southwest Fabricating 302 N/A N/A 100c weld &

Class 1 Piping -

Southwest Fabricating 301 N/A N/A 109C weld SW-11 Class 1 Pipirg -

Southwest Fabrication 291 N/A N/A 109E-1 weld 9 Class 1 Pipirg -

Southwest Fabricating 306 N/A N/A 109f 1 weld 20 Class 1 Piping -

Southwest Fabricating 2386 N/A N/A 1104 1 weld SW 13 Class 1 Pipire -

Southwest Fabricating 2993 N/A N/A 11un-1 mid u Class 1 Piping -

Southwest Fabricating 2993 N/A N/A 111AD-1 weld 6 Class 1 Piping -

Southwest Fabricating 2993 t!/A N/A 111AD 1 weld SW-35 Class 1 Pipirg -

Southwest Fabricating 2993 N/A N/A 111AD 1 weld SW-3f.

Class 1 Piping -

Southwest FebtIcating 4531 N/A N/A 113A 1 weld 2 Class 1 Piping -

Southwest Fabricating 2787 N/A N/A 11u-L mia1 Class 1 Pipirg Stone & Webster Eng. Corp.

N/A N/A N/A Nonseriall2ad Class 2 Piping Stone & Webster Eng. Corp.

N/A N/A N/A NonseriatIred Class 2 Cceponent Stone & Webster Eng. Corp.

N/A N/A N/A t-t Pressuriter Westinghouse 1291 VA 61434 68 104 Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in.,

(2) information in items 1 through 6 on this report isincluded on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

t12/88)

This form (E00029) may be obtained from the Order Dept., ASME,22 Law Drive, Box 2300, Fairfield, NJ 07007 2300.

i l

FORM NIS-1 (Back)

8. Examination Dates 5-30-95 10-6-%

to l

9. Inspection Period Identification
  • =ea wi Portari r12-14 12-14-971
10. Inspection Interval identification sacand Interval (12 14 12-14-2000)
11. Applicable Edition of Section XI N

Addenda

12. Date/ Revision ofInspection Plan amo + 16. 19e6 a.vtalan a. Interim c u _ w as octaher 23. 1996
13. Abstract of Examinations and Tests. Include a list of examinations and tests and a statement conceming status of work irquired for the inspection Plan. Pages 3 - 20
14. Abstract of Results of Examinations and Tests. Pages 3 - 20
15. Abstract of Corrective Measures. Pages 16 - 20 We certify that a) the statements made in this report are correct, b) the exammations and tests meet the Inspection Plan as required by the ASME Code,Section XI, and c) corrective measures taken conform to the rules of the ASME Code,Section XI.

Certificate of Authorization No. (if applicable)

"/"

"/A Expiration Date Date 'ACM;"2

/S 19 @

Signed 1*

b 7

Owner

/- By CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Prest. Vessel Inspectors and the State or Province of Virginia and employed by Hartford steen soller I & I Co. og Hartford, CT have inspected the components described in this Owner's Report during the period

  • hr/H" s c///R to

, and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described 'n this Owner's Report in accordance i

with the Inspection Plan and as required by the ASME Code Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, tests, and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

M cII M 4

Commissions VA-424, INA Inspector's signature Natonal Board state. Pmvince and Endonenwnts Date

  1. t's /8 19 24

Supplcantal Shsst Dock t Number: 50-339 Serial Number: 96-629 j

2 FORM NIS 1 OWNER 1i REPORT FOR INSERVICE INSPECTIONSPage 2 of 20

]

As required by the Provisions of the ASME Code Rules Virginia Electric & Powr Company, 5000 Dominian Blvd., Glen Allen, VA 23060 (Name and Address of Owner)

North Anna Power & cation, P.O. Som 402, Mineral, VA 23117 p

(Name and Address of Plant)

3. Plant Unit
4. Owner Certificate of Authorization (if required)
5. Commercial Service Date
6. National Board Number for Unit
7. Components inspected Manufacturer Component or Manufacturer or Installer State or National Appurtenance or Installer Serial No.

Province No.

Board No.

Reactor Vessel MM Rotterdam 30662 VA 61445 N/A Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x !I in.,

(2) information in items I through 6 on this report isincluded on each sheet,and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(124s)

This form (E00029) may be obtained from the Order Dept., ASME,22 Law Drive, Box 2300, Fairfield, NJ 07007 2300.

Docket Number: 50-339 Serial Number: 96-629 j

Page 3 of 20 4

Virginia Electric and Power Company North Anna Power Station Unit 2 1996 Refueling Outage 4

l 2nd Interval, 2nd Period Introduction This report includes the Interval 2 inservice examinations of Class 1 and Class 2, components, piping and component supports that were conducted at North Anna Power Station Unit 2 from May 30, 1995 to October 6, 1996.

The examinations during the second interval were performed to meet the requirements of ASME Section XI, 1986 Edition.

Examination procedures were approved prior to the examinations being performed.

Certification documents relative to personnel, equipment, and materials were reviewed and determined to be satisfactory.

Inspections, witnessing, and surveillance of the examinations and related activities were conducted by personnel from the Eartford Steam Boiler Inspection and Insurance Company, One State Street, Hartford, CT 06102 (M.

M. Grace and C.

Ireland), North Anna Power Station Quality Assurance Department, and the North Anna Power Station technical staff.

Examinations Examinations were conducted to review as much of the examination zones as was practical within geometric, metallurgical and physical limitations.

When the required ultrasonic examination volume or area could not be examined 100%, the examination method was evaluated and alternate beam angles or methods were considered in an attempt to achieve the maximum examination volume.

However, where 100% examination was not possible the examination was considered to be partial and so noted on the examination report.

Where the reduction in coverage was 10% or greater, per Code Case N-460, a subsequent relief request will be submitted.

Due to leakage identified during startup, some examinations were performed after the official end of the refueling outage, October 6, 1996.

These post-outage activities are included in this report rather than the next report to state the extent of completion of the second period second interval examinations.

The post-outage examinations contained in this report will not be reported in the next NIS-1 report.

Docket Number: 50-339 Serial Number: 96-629 Page 4 of 20 Besults Examinations of components and component supports resulted in no components being reported on the basis of procedure. reporting criteria.

Resolution of Previous NIS-1 commitments The following is a synopsis of open commitments made in previous NIS-1 submittals and their status:

l 1.

Letter Serial No.95-316 Attachment 1, page 7:

A commitment was made to examine spring hanger 2-SHP.-SH-46 on 12050-WMKS-l 0101B during the next period due to a loose jam nut and improper spring l

setting. The examination is scheduled for period 3 in revision 8 of the North Anna Power Station Unit 2 Inservice Inspection Plan for the Second l

Inspection Interval.

2.

Letter Serial No.95-316 Attachment 1, page 7:

A commitment was made to revise drawing 12050-PSSK-110C.06 to correct the spring can size shown for 2-RC-SH-26. The drawing was corrected under revision 2.

l 3.

Letter Serial No.95-316 Attachment 1, page 8:

}

A commitment was made to examine spring hanger 2-CH-R-1 on 12050-WMKS-l 0111W during the next period due to one hex and four washers found to be missing. The examination is scheduled for period 3 in revision 8 of the North Anna Power Station Unit 2 Ir. service Inspection Plan for the Second Inspection Interval.

j 4.

Letter Serial No.94-002 Attachment 1, page 8:

A commitment was made to examine the following welds in the second period.

12050-WMKS-0101A-1 10 12050-WMKS-0102A SW-41 12050-WMKS-0102B SW-27 12050-WMKS-0102C SW-36 Weld 10 on 12050-WMKS-0101A-1 was substituted with weld 27 on the same drawing and examined on 4/21/95.

The remaining three integral attachment welds were removed f rom the inspection plan. Relief req'lest NDE-21 reduced the number of integral attachments required to be examined to 10%. This relief request was approved by the NRC by letter dated 8/8/95, Virginia Power Letter Number 95-429.

4

_.. - ~

- -.. ~... -

Docket Number: 50-339 Serial Number: 96-629 Page 5 of 20 5.

Letter Serial No.95-316 Attachment 1, pages 11, 12, 14, and 15:

j A commitment was made to submit a relief request detailing the limitations for any exam not achieving 90% of the required coverage.

Attachment ~1 page 11 12050-WMKS-0103BV 26 UT NDE-23 page 11 12050-WMKS-0107D 52H PT NDE-29 page 11 12050-WMKS-0109F-2 SW-23 UT NDE-24 page 11 12050-WMKS-0109F-2 SW-43 UT NDE-24 page 11 12050-WMKS-0109F-2 SW-45 UT NDE-24

' page 12 12050-WMKS-0110A-1 SW-14 UT NDE-26 page 12 12050-WMKS-0110A-1 SW-16 UT/PT NDE-27 page 12 12050-WMKS-0110A-1 SW-19 UT/PT NDE-26 page 12 12050-WMKS-0110A-1 SW-24 UT/PT NDE-27 page 12 12050-WMKS-RC-E-2 11 UT NDE-28 page 12 12050-WMKS-RC-E-2 12 UT NDE-28 page 12 12050-WMKS-RH-E-1A 2

UT NDE Attachment 1 page 12 12050-WMKS-SI-TK-2 1

UT Relief Requests NDE 29 were submitted by Letter Serial No.95-327.

The relief requests have been approved by the NRC by Letter Serial No.96-549 dated October 10, 1996. A portion.of weld 1 on l'2050-WMKS-SI-TK-2 is examined each period. A relief request will be submitted, if necessary, after the entire weld has been examined in the third period.

6.-

Letter Serial No.95-316 Attachment 2, page 1 and 2:

A commitment was made to submit a relief request detailing the limitations-for any exam not achieving 90% of the required coverage. page 1 12050-WMKS-CH-P-1B WS-3 PT NDE-30 page 1 12050-WMKS-CH-P-1B WS-4 PT NDE-30 page 2 12050-WMKS-CH-P-1A WS-3 PT NDE-30 page 2 12050-WMKS-CH-P-1A WS-4 PT NDE-30 Relief Requests NDE-30 was submitted by Letter Serial No.95-417. This relief request has been approved by the NRC by Letter Serial No.96-549 dated October 10, 1996.

Analytical Evaluations No analytical evaluations were performed.

Ryaluation Analysag No evaluation analyses were performed for components found to be unacceptable for service as an alternative to repair.

All components found to be unacceptable were repaired or replaced.

l Docket Number: 50-339 Serial Number: 96-629 Page 6 of 20 j

Statement of Interval Status Virginia Electric and Power has completed 61% of Second 10-Year Interval Section XI requirements, i

Abstract of Examinations Performed IWB, IWC & IWF The following examinations were performed to satisfy the second period requirements. All examinations had no reportable indications.

I DRAWING MARK SECTION XI EXAM i

NUMBER NUMBER LINE NUMBER CLASS CATEGORY ITEM METHOD DATE REMARKS j

12050-WMKS-0101D 52 32"-SHP-403-601-Q2 2A C-F 2 C5.51 MT & UT 9/20/96 j

12050-WMKS 0103BK 46 2"-CH-408-1502-01 1A BJ B9.40 PT 9/12/96 12050-WMKS-0109C 1

8" RC-413-2501R-Q1 1A B-J B9.11 PT & UT 9/14/96 12050-WMKS 0109C 4

8"-RC-413 2501R-Q1 1A B-J 89.11 PT & UT 9/14/96 12050-WMKS-0109C SW-11 8" RC-413-2501R-Q1 1A

.BJ B9.32 PT 9/14/96 12050-WMKS-0109E-1 9.

27 1/2"-RC 403 2501R-Q1 1A B-J 89.11 PT & UT 9/23/96 Partial 12050-WMKS-0109F-1 20 31"-RC-405-2501R-Q1 1A B-J B9.11 PT & UT 9/16/96 Partial 12050-WMKS-0110A-1 1

6" RC-437-1502-Q1 1A BJ 89.11 PT & UT 9/18/96 12050-WMKS-0110A-1 SW 13 6" RC-437-1502-01 1A B-J B9.11 PT & UT 9/18/06 Partial 12050 WMKS-0111AAD 52 4"-CH-480-1502-02 2A C F-1 C5.21 PT & UT 9/24/96 12050-WMKS-0111AB 12 2"-CH-405-1502-01 1A B-J B9.21 PT 9/12/96 12050-WMKS 0111AB 9

3"-CH 800-1502-01 1A B-J B9.21 PT 9/12/96 12050-WMKS-0111AD-1 SA 2"-RC-445-1502 01 1A B-J B9.40 PT 9/12/96 12050-WMKS-0111AD-1 6-2" RC 445-1502-01 1A B-J 89.40 PT 9/12/96 12050-WMKS-0111AD 1 SW 33 2" RC-445-1502-Q1 1A B-J 99.40 PT 9/12/96 12050-WMKS-0111Au-1 SW-34 2"-RC 445-1502-Q1 1A B-J B9.40 PT 9/12/96 12050-WMKS-0111W 6A 3"-CH-814-1502-Q1 1A B-J B9.21 PT 9/19/96 12050-WMKS-0113A-1 2

14"-RH 401-1502-01 1A B-J 89.11 PT & UT 9/12/96 12050-WMKS-0113A 4 1 12"-RC-422-1502 01 1A B-J 89.11 PT & UT 9/12/96 12050 WMKS-RC-E 2 9

2-RC E-2 1A B-D B3.110 VT-2 9/08/96 Relief Request NDE-16 12050-WMKS-RC R-1.1 2-RC-INT 2 RC-R 1 1A B-N-1 B13.10 VT-3 9/16/96 12050-WMKS-RC-R 1.1 1 2-RC-R 1 1A B-A B1.30 UT 9/13/96 i

12050-WMKS RC R 1.2 1

'2 RC-R-1 1A BA B1.40 MT/UT 9/17/96 Partial 12050-WMKS-RC-R-1.2 MC-03 2-RC R-1 1A B G-2 87.80 VT-1 9/18/96 l

12050 WMKS RC-R-1.3 TIF-27 2 RC R-1 1A B-G-1 B6.40 UT 9/13/96 12050-WMKS RC-R-1.3 TIF-28 2-RC-R 1 1A B-G 1 86.40 UT 9/13/96 j

12050 WMKS-RC R-1,3 TIF-29 2 RC-R 1 1A B-G-1 B6.40 UT 9/13/96 12050-WMKS-RC-R 1.3 TIF-30 2-RC-N-1 1A B-G-1 B6.40 UT 9/13/96 12050-WMKS-RC R-1.3 TIF-31 2-RC-R 1 1A B G-1 86.40 UT 9/13/96 j

12050 WMKS-RC-R-1.3 TIF-32

-2 RC-R 1 1A B-G-1 B6.40 UT 9/13/96 REMARKS Partial -

Partial examination, (reduction in coverage is greater than 10% as allowed by Code Case N-460) relief request will be provided by separate correspondence).

System Pressure Tests The following system pressure tests were performed to satisfy the second period requirements. All system pressure test were l

ccesptable.

ASME XI Test No.

Test Zone Category item No. Examination Date 2-CA-002 INSTRUMENT AIR - PENETRATION 47 TEST DUR11G THIRD INTERVAL TESTING.

i 2-SPM-082F-2-1 C-H C7.30 09/18/96 2-SPM-082F 2-1 C-H C7.70 09/18/96 I

1 l

l l

Docket Number: 50-339 Serial Number: 96-629 Page 7 of 20 ASME XI Test No.

Test Zone Category item No. Examination Date 2-CC-006 COMPONENT COOLING TO RECIRCULATION AIR FANS 2-SPM 0798-3 1 CH C7.30 09/08/96 2-SPM-0798 3-1 C-H C7.70 09/08/96 2 CH 002 LETDOWN 2-SPM-095C-1-1 BP B15.40 10/11/96 2-SPM-095C-1-1 BP B15.50 10/11/96 2-SPM-095C-1-1 8-P B15.70 10/11/96 2-CH-004 EXCESS LETDOWN HEAT EXCHANGER 2 SPM-095C-2-6 BP B15.50 10/11/96 2 SPM 095C-2 6 8-P B15.60 10/11/96 2 CH-005 LOOP FILL HEADER 2-SPM-093A-1 3 B-P B15.50 09/29/96 2 SPM 093A-1-3 B-P B15.70 09/29/96 2 SPM 093A 2-3 BP B15.50 09/29/96 2 SPM-093A-2-3 B-P B15.70 09/29/96 2-SPM-093A-3-4 B-P B15.50 09/29/96 2-SPM-093A-3-4 B-P B15.70 09/29/96 2-SPM-095C-1 4 BP B15.50 09/29/96 2-SPM-095C-1 4 B-P B15.70 09/29/96 2-SPM-095C-1-4 C-H C7.30 09/29/96 2-SPM 095C-1-4 C-H C7.70 09/29/96 2 SPM-096A 3-6 C-H C7.30 09/29/96 2-SPM-096A-3-6 C-H C7.70 09/29/96 2-CH-006 SEAL INJECTION TO RCP'S 2-SPM-095C-2-3 B-P B15.50 10/11/96 2-SPM-095C 2 3 BP B15.70 10/11/96 2-SPM-095C-2-4 BP B15.50 10/11/96 2-SPM-095C-2-4 BP B15.70 10/11/96 2-SPM-095C-2-5 B-P B15.50 10/11/96 2-CH-007 NORMAL CHARGING HEADER 2-SPM-095A-1 1 C-H C7.10 09/08/96 2-SPM-095A-1-1 C-H C7.30 09/08/96 2-SPM-095A-1-1 C-H C7.70 09/03/96 2-SPM-095A-2-1 C-H C7.10 09/08/96 2 SPM-095A-2-1 C-H C7.30 09/03/96 2-SPM-095A-2-1 CH C7.70 09/08/96 2-SPM 095A 2-3 C-H C7.30 09/08/96 j

2-SPM-095A-2-3 C-H C7.70 09/08/96 2 SPM-095A-2-4 C-H C7.30 09/08/96 2-SPM-095A-2-4 C-H C7.70 09/08/96 1

2 SPM 095A-2->

C-H C7.30 09/08/96 2 SPM-095A 2-5 C-H C7.70 09/08/96 2-SPM-095B-1-1 C-H C7.30 09/08/96 2 SPM 095B 1-1 C-H C7.70 09/08/96 2-SPM 095B-1-2 C-H C7.10 09/08/96 2-SPM-095B-1 2 C-H C7.30 09/08/96 2-SPM 095B-1 2 C-H C7.70 09/08/96 2-SPM-0958-1-7 C-H C7.10 09/08/96 2-SPM-0958-1-7 CH C7.30 09/08/96 2 SPM-0958 1-7 C-H C7.70 09/08/96 2 SPM-095B 1-8 C-H C7.30 09/08/96 2-SPM-095B-1-8 C-H C7.70 09/08/96 2-SPM-095B-2 1 CH C7.30 09/08/96 2-SPM-095B-2-1 C-H C7.70 09/08/96 2-SPM-0958-2-10 C-H C7.30 09/08/96

)

2-SPM 0958 2-10 C-H C7.70 09/08/96 l

2-SPM-0958-2-2 C-H C7.30 09/08/96

(

2-SPM-095B 2 2 C-H C7.50 09/08/96 2-SPM-0958-2-2 C-H C7.70 09/08/96 2-SPM-095B-2-3 CH C7.30 09/08/96 l

2-SPM-095B-2-3 C-H C7.50 09/08/96 l

Docket Number: 50-339 Serial Number: 96-629 Page 8 of 20 ASME XI TQet No.

Test Zone Catenorv item No. Examination Date 2 CH 007 NORMAL CHARGING HEADER Continued 2 SPM-0958-2-3 C-H C7.70 09/08/96 1

2 SPM-095B 2-4 C-H C7.30 09/08/96 2-SPM 095B 2-4 C-H C7.50 09/08/96 2-SPM-095B-2-4 C-H C7.70 09/08/96

-2 SPM-095B-2-5 C-H C7.30 09/08/96 2 SPM-095B 2-5 C-H C7.70 09/08/96 2 SPM-095B-2-6 C-H C7.30 09/08/96 2-SPM-095B 2 6 C-H C7.70 09/08/96 2 SPM-095C-1-3 C-H C7.30 09/08/96 2-SPM 095C-1 3 C-H C7.70 09/08/96 2-SPM-095C-1-8 C-H C7.30 09/08/96 2-SPM-095C-1-8 CH C7.70 09/08/96 2-SPM-095C-2-1 CH C7.10 09/08/96 2 SPM-095C-2-1 C-H C7.30 09/08/96 2-SPM 095C-2-1 C-H C7.70 09/08/96 2-SPM-096A 3-4 C-H C7.30 09/08/96 2-SPM-096A-3 4 C-H C7.70 09/08/96 2-SPM-096A-3-5 CH C7.30 09/08/96 2-SPM-0964-3-5 C-H C7.70 09/08/96 2-CH 008 CHARGING CROSS-TIE UNIT 2 TO UNIT 1.

2-SPM-0958-2 9 CH C7.30 09/08/96 2-SPM-095B 2-9 C-H C7.70 09/08/96 2-DA-004 PRIMARY VENT POT (2-DA TK-1) DISCHARGE PEN. 54.

2 SPM-090A-3-3 C-H C7.30 09/08/96 2 SPM-090A 3 3 C-H C7.70 09/08/96 2 FP-001 FIRE PROTECTION PENETRATION 34 2-SPM-104A-1 1 C-H C7.70 09/09/96 2-QS-003 QUENCH SPRAY RECIRC TO RWST 2-SPM-091A-1-2 CH C7.30 07/12/96 2-SPM-091A-1-2 C-H C7.70 07/12/96 2*SPM 091A 1-3 C-H C7.30 07/12/96 2 SPM-091A-1-3 C-H C7.70 07/12/96 2-SPM-091A 1-4 C-H C7.30 07/12/96 2 SPM-091A-1-4 CH C7.70

-07/12/96 2-SPM-091A-1 5 C-H C7.30 07/12/96 2-SPM 091A-1-5 C-H C7.70 07/12/96 2 SPM 091A-1-7 C-H C7.30 07/12/96 2 SPM 091A-1-7 CH C7.50 07/12/96

-2 SPM-091A 1-7 CH C7.70 07/12/96 2-SPM 091A-2-1 C-H C7.30 07/12/96 2-SPM 091A-2-1 C-H C7.50 07/12/96 2 SPM-091A-2-1 C-H C7.70 07/12/96 2 SPM-091A-2 2 C-H C7.30 07/12/96 2-SPM-091A 2 2 CH C7.50 07/12/96 2-SPM-091A-2-2 C-H C7.70 07/12/96 2-SPM 091A-2-3 C-H C7.30 07/12/96 2-SPM 091A-2-3 C-H C7.70 07/12/96 D SPM-091A-2-6 CH C7.30 07/12/96 2-SPM-091A-2-6 C-H C7.70 07/12/96 2-RC-001 REACTOR COOLANT SYSTEM 2 SPM-0898+1-1 B-P B15.50 10/12/96 2-SPM-0898-1-1 B-P B15.70 10/12/96 2-SPM-089B-1-2 C-H C7.30 10/12/96 2-SPM-0898-1-2 CH C7.70 10/12/96 2-SPM-090A-3 4 BP B15.50 10/12/96 2-SPM 090A-3-4 BP B15.70 10/12/96 1

2 SPM-090A-3-5 B-P B15.50 10/12/96 2-SPM-090A 3-5 B-P B15.70 10/12/96 2-SPM 093A 1-1 BP B15.10 10/12/96

Docket Number: 50-339 l

Serial Number: 96-629 Page 9 of 20 i

ASME XI Test No.

Test Zone Category item No. Examination Date 2-RC-001 REACTOR COOLANT SYSTEM Continued 2-SPM 093A-1 1 B-P B15.30 10/12/96 2-SPM-093A-1-1 B-P B15.50 10/12/96 2-SPM 093A-1-1 BP B15.60 10/12/96

.2 SPM-093A-1-1 B-P B15.70 10/12/96 2-SPM-093A-1 2 B-P B15.50 10/12/96 2-SPM-093A-1-2 B-P B15.70 10/12/96 2-SPM-093A-2-1 B-P B15.10 10/12/96 2 SPM 093A 2-1 BP B15.30 10/12/96 2-SPM-093A-2-1 B-P B15.50 10/12/96 2-SPM-093A 2 1 B-P B15.60 10/12/96 2-SPM-093A-2 1 B-P B15.70 10/12/96 2 SPM-093A-2-2 B-P B15.50 10/12/96 2-SPM 093A-2-2 B-P B15.70 10/12/96 2-SPM 093A-3-1 B-P B15.10 10/12/96 2-SPM 093A-3-1 B-P B15.30 10/12/96 2-SPM-093A-3-1 B-P B15.50 10/12/96 2-SPM 093A 3-1 B-P B15.60 10/12/96 2-SPM 093A-3-1 B-P B15.70 10/12/96 2-SPM-093A-3-2 BP B15.50 10/12/96 2-SPM-093A-3 2 B-P B15.70 10/12/96 2-SPM 093A-3-3 B-P B15.50 10/12/96 2-SPM-093A 3-3 B-P B15.70 10/12/96 2-SPM-0938-1 1 BP B15.10 10/12/96 2 SPM-0938 1-1 B-P B15.20 10/12/96 2-SPM-0938-1-1 B-P B15.50 10/12/96 2-SPM-0938-1-1 B-P B15.70 10/12/96 2 SPM-093B-1 2 B-P B15.50 10/12/96 2-SPM-0938-1 2 BP B15.70 10/12/96 2 SPM 0938-1-3 B-P B15.50 10/12/96 2-SPM-093B-1-3 B-P B15.70 10/12/96 2 SPM-0938-1-4 B-P B15.50 10/12/96 2-SPM-093B-1-4 B-P B15.70 10/12/96 2-SPM-0930-1-1 B-P B15.10 10/12/96 2-SPM-0930-1-1 B-P B15.50 10/12/96 2 SPM-093D-1-1 BP B15.70 10/12/96 2-SPM-093D-2 1 BP B15.50 10/12/96 2-SPM-0930-2-1 B-P B15.70 10/12/96 2-SPM 094A-1-1 BP B15.50 10/12/96 2-SPM-094A-1-1 B-P B15.70 10/12/96 2-SPM-094A 2-1 B-P B15.50 10/12/96 2-SPM-094A-2-1 BP B15.70 10/12/96 2-SPM-094A 2 2 B-P B15.50 10/12/96 2-SPM-094A-2-2 B-P B15.70 10/12/96 2 SPM 095C-1 2 B-P B15.50 10/12/96 2-SPM-095C-1-2 B-P B15.70 10/12/?6 2-SPM-0968 1-1 B-P B15.50 10/12/96 2-SPM-0968 1-1 B-P B15.70 10/12/96 2-SPM-0968-1-3 BP B15.50 10/12/96 2-SPM 0968-1-3 B-P B15.70 10/12/96 2 SPM-0968-1-3 C-H C7.30 10/12/96 2-SPM 0968-1-3 C-H C7.70 10/12/96 2-SPM-096B-2 1 B-P B15.50 10/12/96 2-SPM-0968-2-1 B-P B15.70 10/12/96 2-SPM-0968-2-3 B-P B15.50 10/12/96 2-SPM-096B-2-3 B-P B15.70 10/12/96 2-SPM-0968-2-3 C-H C7.30 10/12/96 2-SPM-096B-2-3 C-H C7.70 10/12/96 2-SPM-0968-3-1 B-P B15.50 10/12/96 2-SPM-096B-3-1 B-P B15.70 10/12/96 2 SPM-096B 3-3 B-P B15.50 10/12/96 2-SPM-096B-3-3 BP B15.70 10/12/96 2-SPM 096B-3-3 C-H C7.30 10/12/96 2-SPM-0968-3-3 C-H C7.70 10/12/96 l

2-SPM-0968-4-1 B-P B15.10 10/12/96 2-SPM-096B 4-1 B-P B15.50 10/12/96

-- -,.~..- -...-.-_

4 Docket Number: 50-339 Serial Number: 96-629

}

Page 10 of 20 ASME XI T*st No.

Test Zone Categorv Item No. Examination Date 4

2-RC-001 REACTOR COOLANT SYSTEM Continued i

2 SPM-0968-4-1 B-P B15.70 10/12/96 1

1 2 RP 001 RP TO REACTOR CAVITY, PEN. 103.

l 1-SPM-088A 3-1 CH C7.30 09/17/ %

1-SPM 088A-3-1 C-H C7.70 09/17/96 2-RP-002 RP TO REACTOR CAVITY, PEN. 104, 1-SPM 088A-3 2 C-H C7.30 09/17/96 1-SPM 088A 3-2 C-H C7.70 09/17/96 l-2-RS 005 2-RS-P-3A To 2 RS-P-2A SUCTION.

2-SPM 0918-1-2 C-H C7.30 08/19/96 j

j 2 SPM-0918-1-2 C-H C7.70 08/19/96 j

2-RS 006 2-RS P-3B TO 2-RS-P-2B SUCTION.

2-SPM 0918-1 1 C-H C7.30 09/30/ %

i i

2-SPM-0918-1 1 C-H C7.70 09/30/96 3

2-RS 009 2 RS P-2A SUCTION / DISCHARGE OR$.

Note 1

)

2-SPM 091A-4-4 C-H C7.30 10/03/96 2-SPM-091A-4 4 C-H C7.50 10/03/ %

2 SPM-091A-4-4 C-H C7.70 10/03/%

i 2 RS 012 2 RS-P 2B SUCTION / DISCHARGE ORS.

Note 1 i

2-SPM-091A 4 3 C-H C7.30 05/15/95 2-SPM-091A-4-3 C-H C7.50 05/15/95 2 SPM-091A-4-3 C-H C7.70 05/15/95 2 SI-004 ACCUMULATOR N2 VENT, PENETRATION 50 1

2-SPM-0968-1-4 C-H C7.30 09/08/96 2-SPM 0968-1-4 C-H C7.70 09/08/96 2-SI-011 CHARGING TO CL, PEN. 11.

f 2 DM 0968-4-5 BP B15.50 10/11/96

]

2-SPo-0968 4-5 B-P B15.70 10/11/96 2-$1-014 HHSI, L3ARGING TO HL, PEN. 114.

2-SPM-0968-4 7 B-P B15.50 10/11/96 2-SPM-0968-4 7 B-P B15.70 10/11/96 i

2-SS 001 SG SAMPLE TO PEN. 56.

2 SPM-089A-3 4 C-H C7.30 09/10/96 2 SPM-089A-3-4 C-H C7.70 09/10/96 1

2 SW 001 SW TO RECIRC. SPRAY HEAT EXCHANGER 1-SPM 0788-3 2 C-H C7.10 09/09/96 j

1-SPM-0788-3-2 C-H C7.30 09/09/96 1-SPM-078B 1 2 C-H C7.70 09/09/96 4

1-SPM-0788-3-3 C-H C7.10 09/09/96 1-SPM 0788-3-3 C-H C7.30 09/09/96 1-SPM 0788-3-3 C-H C7.70 09/09/96 2 SW-002 SW TO RECIRC SPRAY HEAT EXCHANGER 1-SPM-0788-3-1 CH C7.10 09/09/96 1-SPM 0788-3 1 C-H C7.30 09/09/96 1-SPM-0788-3 1 C-H C7.70 09/09/96 i

1-SPM 0788 3-4 C-H C7.10 09/09/96 1-SPM-0788-3 4 C-H C7.30 09/09/96 i

i Docket Number: 50-339 Serial Number: 96-629 Page 11 of 20 ASME XI i

Ttst No.

Test Zone Categorv Item No. Examination Date 2 SW-002 SW TO RECIRC SPRAY HEAT EXCHANGER Continued 1 SPM-0788-3-4 CH C7.70 09/09/96 2-VT-001 2 RC E-1A, SG WET LAY-UP, PEN 32.

2-SPM 1028-1 4 CH C7.30 09/08/96 2-SPM-1028 1-4 CH C7.70 09/08/96

+

2 WT-002 2-RC-E 18A, SG WET LAY-UP, PEN 100.

2 SPM-1028 1-5 CH C7.30 09/08/96 2-SPM-1028-1 5 CH C7.70 09/08/96 2-WT-003 2-RC E 1BA, SG WET LAY-UP, PEN 108.

2-SPM-1028-1-6 C-H C7.30 09/08/96 1

2-SPM-1028 1 6 CH C7.70 09/08/96 j

Note 1 The 10 minute hold time required by IWA 5213(b) was not achieved during the testing of the outside recire. spray pumps (2-RS P-2A pressure test 2-RS 009 and 2 RS-P-28 pressure test 2-RS-012), due to test loop configuration and pump seal design. A relief request will be submitted or the test will be repeated with a 10 minute hold time prior to the end of the second period, 1

12/14/97.

l The following items numbers were reported in the 1995 NIS-1 report as having been pressure tested. Subsequent to the 1995 NIS-1 report a review of the pressure test program was performed and determined that these item numbers did not exist for the specific test zone or the item is being tracked under the Inservice Inspection Plan for Components and Component Supports. These item numbers have been removed from the pressure test program.

ASME XI

Test No.

Test Zone Category item No.

2-80 001 2-SPM-098A 2-1 CB C2.33 2-SPM-098A-2 1 C-H C7.10 2 80-002 2-SrM 098A-3-1 C-B C2.33 2 SPM 098A 3-1 CH C7.10 2-B0 003 2-SPM 098A-4 1 C-B C2.33 2 SPM-098A-4 1 CH C7.10 2-FW 001 2 SPM-074A 1 1 C-B C2.33 2-SPM 089A-3-1 CB C2.33 2-SPM 102A-2-1 C-B C2.33 2 SPM-1028-1-1 CB C2.33 2 FW-002 2-SPM-074A-1-2 CB C2.33 2-SPM-089A-3-2 C-B C2.33 i

2-SPM-102A-2-2 C-B C2.33 l

2-SPM 102B-1-2 C-B C2.33 4

2-FW-003 2-SPM-074A 1-3 C-B C2.33 2-SPM-089A 3-3 C-B C2.33 2 SPM 102A-2-3 C-B C2.33 2-SPM 1028-1-3 CB C2.33 2-MS 001 2-SPM-070B 1-1 C-B C2.33 2-MS 002 2-SPM-0708 2 1 C-B C2.33 2-MS-003 2-SPM-0708-3 1 C-8 C2.33 2 MS-004 2 SPM-0708 2-3 CB C2.33

m._

'1 1

Docket Number: 50-339 Serial Number: 96-629 Page 12 of 20 i

ASME XI i

Test No.

Test Zone Catenory item No.

l 2-RC-001 4

2 SPM 094A*1*1 BP B15.10 2 SPM-095C-1 2 BP B15.10 2 SPM-0968-1-1 BP B15.10 2 SPM 0968 2-1 B-P

-B15.10

]

2-SPM-0968 3 1 BP B15.10 1

2 51-001 i

2-SPM-0968-1 2 C-B C2.33 I

2-SI-002 2 SPM 0968-2-2 C-B C2.33

]

2-SI-003

.2-SPM-0968 3 2 C-B C2.33 2-SI-010 j

2 SPM-096A-2-3 CH C7.30 2-51-011 j

2 SPM 096A 3-1 C-B C2.33 I

Nots Code Cases N 522 and N 498 that were referenced in the 1995 NIS 1 report were not applicable to the pressure test performed during that inspection period.

j-The following item numbers were not reported in the 1995 NIS-1 report as having been pressure tested. These item numbers were omitted from the i

pressure test reporting in error. These item numbers and test completion dates are reported in this NIS-1 report in order to document the completion

. status for Period 2 for the Class 1 and 2 pressure tests.

i I

ASME XI i

i T*St No.

Test Zone Catenorv Item No. Examination Date 2-BD-001

}

2-SPM 098A-2-1 C-H C7.30 03/25/95 2 SPM 098A-2-1 CH C7.70 03/25/95 2-B0-002 J

2-SPM 098A-3-1 CH C7.70 03/25/95 2 BD-003 e

i 2-SPM-098A 4-1 C-H C7.30 03/25/95 2 SPM-098A-4-1 C-H C7.70

'03/25/95 i

2 CA-001 2-SPM 082A-1-1 C-H C7.30 04/06/95 2 SPM 082A-1-1 CH C7.70 04/06/95 1

2-CA-003 4

2-SPM-0828-2-1 CH C7.70 03/27/95

)

l 2-CA-004 i

2-SFM-0828 2 2 C-H C7.70 03/27/95 2 CC 001 2-SPM-079A-1*2 C-H C7.70 03/30/95 1

2-SPM 079A-1-3 C-H C7.70 03/30/95 1

2-CC-003 j.

2-SPM-079A 2-3 C-H C7.70 03/25/95 2 CC-004 1

2 SPM-079A-3-3 C-H C7.70 03/25/95 4

2-CC-005 i

2-SPM 079A-4-3 C-H C7.70 03/25/95 2-CC-007 l

2-SPM-079A-1-4 C-H C7.70 03/25/95 2

2-CH 001 2 SPM-0958-1-3 C-H C7.70 03/25/95

}

2-CH-002 2-SPM-095A 2-2 CH C7.70 03/25/95 4

2-SPM 095C-1 1 BP B15.50 03/25/95 4

2 SPM 095C-1-1 BP B15.70 03/25/95 1

2-SPM 095C-1-1 C-H C7.30 03/25/95 2 SPM-095C-1-1 C-H C7.70' 03/25/95 2-SPM-095C-1-9 CH C7.70 03/25/95 1

1 I

Docket Number: 50-339 Serial Number: 96-629 Page 13 of 20 ASME XI 70st No.

Test Zone Category item No. Examination Date 2-CH-004 j

1 2-SPM 0958-1-6 CH C7.70 03/25/95 2-SPM 095C-1-10 C-H C7.70 03/25/95 2-SPM-095C-1-5 C-H C7.70 03/25/95 2 SPM-095C-2-2 C-H C7.70 03/25/95 2-SPM 095C 2-6 BP B15.60 03/25/95 2-SPM 095C 2-8 CH C7.70 03/25/95 2-CH 0US 2-SPM-093A 1-3 B-P B15.50 03/25/95 2-SPM-093A 1-3 B-P B15.70 03/25/95 2-SPM-093A-2-3 BP B15.50 03/25/95 2-SPM-093A-2-3 B-P B15.70 03/25/95 2-SPM 093A-3 4 B-P B15.50 03/25/95 2 SPM-093A-3-4 B-P B15.70 03/25/95 2-SPM 095C-1-4 BP B15.50 03/25/95 2-SPM 095C-1-4 B-P B15.70 03/25/95 2-CH 006 2-SPM 095C-2-3 BP B15.70 03/25/95 2-SPM-095C-2-4 BP B15.70 03/25/95 2 SPM-095C-2-7 C-H C7.70 03/25/95 2 CV-001 2-SPM 092A 2-1 C-H C7.70 03/28/95 2-SPM-106A-4-4 C-H C7.70 03/28/95 2-SPM-106A 4-5 C-H C7.70 03/28/95 2-CU 002 2-SPM-092A-2-2 CH C7.70 03/28/95 2 SPM-106A-4 3 C-H C7.70 03/28/95 2 SPM-106A-4-6 C-H C7.70 03/28/95 2 CV 003 g-SPM-092A-2-3 CH C7.70 03/28/95 2-DA-001 2-SPM-090A-3 1 C-H C7.70 03/28/95 2-SPM 0908-1-1 CH C7.7D 03/28/95 2 DA 002 2-SPM 090A-1-2 C-H C7.70 03/26/95 2-DA 003 2-SPM-090A-1-1 C-H C7.70 03/26/95 2 DA-005 2-SPM-090A-3-2 C-H C7.70 03/31/95 2-FB-001 2-SPM-074A-1-1 C-H C7.10 03/25/95 2-SPM 074A-1 1 C-H C7.30 03/25/95 2-SPM 074A-1 1 CH C7.70 03/25/95 1

2-SPM-089A-3-1 C-H C7.30 03/25/95 2-SPM-089A-3-1 CH C7.70 03/25/95 2-SPM-102A-2-1 C-H C7.30 03/25/95 2-SPM-102A 2-1 C-H C7.70 03/25/95 2-SPM-102A-2-4 C-H C7.70 03/25/95 2-SPM-1028-1 1 C-H C7.30 03/25/95 2-SPM 102B-1-1 C-H C7.70 03/25/95 2 FW-002 2-SPM-074A-1-2 C-H C7.10 03/25/95 2-SPM 074A-1-2 C-H C7.30 03/25/95 2-SPM 074A 1-2 CH C7.70 03/25/95 2-SPM 089A 3-2 CH C7.30 03/25/95 2-SPM-089A-3-2 C-H C7.70 03/25/95 2 SPM 102A 2-2 C-H C7.30 03/25/95 2-SPM-102A-2-2 C-H C7.70 03/25/95 2-SPM 102A-2 5 C-H C7.70 03/25/95 2-SPM-1028-1-2 C-H C7.30 03/25/95 2-SPM-102B-1-2 C-H C7.70 03/25/95 2-FW-003 2 SPM-074A-1-3 CH C7.10 03/25/95 2-SPM-074A-1-3 C-H C7.30 03/25/95 2-SPM-074A-1-3 C-H C7.70 03/25/95 2-SPM-089A-3 3 C-H C7.30 03/25/95

Docket Number: 50-339 Serial Number: 96-629 Page 14 of 20 ASME X1 Tes? No.

Test Zone Catenory item No. Examinat f on Date 2-FW-003 Continued 2 SPM 089A 3-3 CH-C7.70 03/25/95

.2 SPM 102A-2-3 C-H C7.30 03/25/95 2-SPM 102A 2 3 C-H C7.70 03/25/95-2-SPM-102A 2-6 C-H C7.70 03/25/95 2-SPM-1028-1 3. C-H C7.30 03/25/95 2 SPM-1028-1 3 CH C7.70 03/25/95 2-HC-001 2 SPM-106A-1 4 C-H C7.70 03/28/95 2 HC-002 2 SPM 106A 1 1 C-H C7.70 03/29/95 2 SPM-106A 1-5 C-H C7.70 03/29/95 2-HC-003 2-SPM-106A-2-4 C-H C7.70 03/29/95 2 HC-004 2-SPM-106A 2-1 CH C7.70 03/29/95 2-SPM-106A 2-3 C-H C7.70 03/29/95 2-HC-005 2 SPM-106A-3-2 C-H C7.70 03/29/95 2 HU-001 2 SPD 006A-2-1 C-H C7.70 03/25/95 2-HV-002 2 SPB 006A-2-2 CH C7.70 03/25/95 3-LM-001 2-SPM-092A-1-1 C-H C7.70 03/28/95 2 SPM-092A-1 2 CH C7.70 03/28/95 2-MS-001 i SPM-0708-1 1 C-H C7.70 03/25/95 l

2-SPM 0708-2-1 -C-H C7.70 03/25/95 l

2-SPM 0708 3-1 C-H C7.70 03/25/95 2-MS-002

)

2 SPM-0708-2-2 C-H C7.30 03/25/95 l

2-SPM-070s 2-2 C-H CT.70 03/25/95 l

2 MS-003

. 03/25/95 l

2 SPM-0708-3-2 CH C7.30 l

2-SPM 0708-3-2 C-H C7.70 03/25/95 1

2-MS-004' 2 SPM-0708 1 2 C-H C7.30 02/20/95 2-SPM 0708-1 2 C-H C7.70 02/20/95

'2 SPM-0708 2 3 C-H C7.30 02/20/95 2-SPM 0708-2-3. C-H C7.70 02/20/95 l

2 SPM 0708 3 3 C-H C7.30 02/20/95 l

2-SPM 0708-3-3 C-H C7.70 02/20/95 i

2-RC-001 2-SPM-0898 1-1 B-P B15.50 05/30/95 2-SPM-0898-1 2 B-P B15.50 05/30/95 2-SPM 090A 3 4 B-P B15.50 05/30/95 l

2-SPM-090A 3-5 BP B15.50 05/30/95 2 SPM 093A-1 1 B-P B15.30 05/30/95 2-SPM-093A 1-1 BP B15.50 05/30/95 2-SPM-093A-1 1 B-P B15.60 05/30/95 2-SPM-093A-1-1 8-P B15.70 05/30/95 2-SPM-093A-1-2 BP B15.70 05/30/95 2-SPM 093A-2-1 BP B15.30 05/30/95 2-SPM 093A-2-1 BP B15.50 05/30/95 2-SPM-093A-2-1 B-P B15.60 05/30/95 2 SPM-093A-2-1 B-P B15.70 05/30/95 2 SPM-093A 2-2 BP B15.70 05/30/95 2-SPM-093A 3-1 B-P B15.30 05/30/95 I

2 SPM 093A-3 1 BP B15.50 05/30/95 2-SPM 093A-3 1 B-P B15.60 05/30/95 2-SPM 093A-3-1 B-P B15.70 05/30/95 2-SPM-093A-3-2 B-P B15.70 05/30/95 2-SPM-093A-3-3 BP B15.70 05/30/95 2-SPM-0938-1-1 BP E15.20 05/30/95 2-SPM 0938-1 1 B-P B15.50 05/30/95 I

1

~.

I i

Docket Number:' 50-339 Serial Number: 96-629 Page 15 of 20 ASME XI fe*t No.

Test Zone Catenorv Item No. Examination Date 2-RC-001 Continued i

2 SPM 0938-1-1 B-P B15.70.05/30/95 2 SPM-0938 1-2 B-P B15.70' 05/30/95 2-SPM 0938-1-3 B-P B15.70 05/30/95 2-SPM-093B 1 4 BP B15.70 05/30/95 2-SPM-0930-1-1 B-P B15.50 05/30/95 2-SPM-0930-1-1 8-P B15.70 05/30/95 2 SPM 093D-2-1 B-P B15.70 05/30/95 2-SPM-094A-1-1 BP B15.50 05/30/95 2-SPM 094A-1 1 BP B15.70 05/30/95 2 SPM 094A-2-1 B-P B15.70 05/30/95 2 SPM 094A 2-2 BP 815.70 05/30/95 i

2-SPM-095C 1 2 BP B15.50 05/30/95 2-SPM-095C-1-2 B-P B15.70 05/30/95 3

2 SPM-0968-1-1 B-P B15.50 05/30/95 2-SPM 0968-1-1 BP B15.70 05/30/95 2 SPM-0968 1-3 B-P B15.70 05/30/95 2 SPM-0968-1-3 CH C7.30 05/30/95 2 SPM-0968-1-3 CH C7.70 05/30/95 2-SPM-0968 2-1 B-P B15.50 05/30/95 2-SPM 0968 2-1 B+P B15.70 05/30/95 2-SPM 0968-2-3 B-P B15.70 05/30/95 2 SPM-0968-2-3 C-H C7.30 05/30/95 2-SPM 0968-2-3 CH C7.70 05/30/95 2 SPM-0%B-3 1 BP B15.50 05/30/95

)

2-SPM 0968 3-1 BP B15.70 05/30/95 2-SPM-0968 3-3 BP B15.70 05/30/95 2 SPM 0968 3-3 CH C7.30 05/30/95 2-SPM-0968-3-3 C-H C7.70 05/30/95 2-SPM-0968-4-1 8-P B15.50 05/30/95 2-SPM 096B 4-1 B-P

'B15.70 05/30/95 2-RC-002 2-SPM 0938-2-1 CH C7.70 03/30/95 2 RH-001 2 SPM-0898 1-3 C-H C7.30 03/30/95 2 SPM 094A-1-2 C-H C7.30 03/30/95 2-SPM-094A 1-2 C-H C7.50 03/30/95 2-SPM 094A-1 2 C-H C7.70 03/30/95.

2-SPM-094A-1 3 C-H C7.70 03/30/95

'2 SPM-094A-1 4 CH C7.70 03/30/95 2-SPM-094A-2 4 C-H C7.70 03/30/95 2 SPM 094A-2 6 CH C7.70 03/30/95 2 SPM 095C-1 7 C-H C7.70 03/30/95 2-RH-002 2-SPM-094A-2-5 C-H C7.30 03/30/95 2-SPM-094A 2-5 C-H C7.70 03/30/95 2-RS-001 2-SPM-091A-3-3 CH C7.50 04/07/95 2 SPM-091A-3-3 C-H C7.70 04/07/95 2 RS-002 2 SPM 091A-3-2 C-H C7.70 04/07/95 2 RS-007 2 SPM 091A-4-5 CH C7.30 04/07/95 Changed item nunber from C7.40 2-SPM-091A-4 5 C-H C7.70 04/07/95 2 SPM-0918-1-6 C-H C7.70 04/07/95 2-51-001 2-SPM 0968 1-2 C-H C7.10 03/25/95 2 SPM-0968 1-2 C-H C7.30 03/25/95 2-SPM-0968-1 2 C-H C7.70 03/25/95 2-SI-002 2-SPM 0968-2-2 C-H C7.10 03/25/95 2 SPM 0968-2 2 CH C7.30 03/25/95 2 SPM-0968-2 2 C-H C7.70 03/25/95 i

Docket Number: 50-339 Serial Number: 96-629 Page 16 of 20 ASME XI-Ttst No.

Test Zone Category item No. Examination Date 2 SI 003 2 SPM-0968 3-2 C-H C7.30-03/25/95 2 SPM 0968-3 2~ C-H C7.70 03/25/95 2 SI-005 2-SPM-0968 1 5 C-H C7.70 03/30/95 2-SI-006 2-SPM-096A-1-4 C-H C7.30 04/07/95 2-SI 007 SPM 096A-1 5 C-H C7.70 03/26/95 I

2-SPM-0968-1 6 C-H C7.70 03/26/95 2-51-008 2-SPM-096A-2-9 C-H C7.70 03/26/95 2-SPM 0968-1-7 CH C7.70 03/26/95 2 $1-009 2-SPM-096A-1-1 C-H C7.50 05/24/95 2-SPM 096A-1-1 C-H CT.70 05/24/95 2-SPM 096A 2-1 CH C7.70 05/24/95 2-SPM-096A ^-4 CH

.CT.30 05/24/95 Changed item nunber from C7.40 2-SPM-096A 2-4 C-H C7.70 05/24/95 2-SPM 096A 2-5 C-H C7.70 05/24/95 2-S1-010' 2-SPM 088A-1-6 C-H C7.30 05/24/95 2 SPM 088A 1-6'C-H r7.70 05/24/95 2 SPM 091A-1-1 C-H C7.70 05/24/95 2 SPM 0958-2-7 C-H C7.70 05/24/95 2-SPM-0958 2 8 C-H C7.70 05/24/95 2-SPM-096A-1-2 C-H C7.50 05/24/95 2-SPM 096A-1-2 C-H C7.70 05/24/95 2-SPM-096A-1-3 CH C7.70 05/24/95 2-SPM-096A-2 10 C-H C7.70 05/24/95 2-SPM 096A-2-2 CH C7.70 05/24/95 2 SI-011 2-SPM-096A-3-1 C-H C7.10 05/24/95 i

2 SPM-096A 3-1 C-H C7.30 05/24/95 2-SPM-096A-3-1 C-H C7.70 05/24/95 2-SPM 0%8-4-5 8P 815.70 05/24/95 2 SPM 0968-4-5 C-H C7.30 05/24/95 2-SPM 0%B 4 5 C-H

-C7.70 05/24/95 2 SPM 0%8-4-8 C-H C7.70 05/24/95 2-SI 012 2 SPM 0968-4-6 CH C7.70 05/24/95 2 SI 013 2-SPM-0968-4-9 C-H C7.70 05/24/95 2 SI-014

{

2 SPM 096A-3-2 CH C7.70 05/24/95 2 SPM-0968 4-7 8P 815.70 05/24/95 1

2-SPM 0968 4 7 CH C7.30 05/24/95 l

2-SPM-0968 4-7' C-H C7.70 05/24/95 2 51-015 2-SPM 096A 2-6 C-H C7.70 05/24/95 2-SPM-096A-4 2 C-H C7.70 05/24/95 2-SI-016 L SPM 096A-2-7 C-H C7.70 05/24/95 2-SPM-0968-4-3 C-H C7.70 05/24/95 2 s! 017 2-SPM 096A-2-8 C-H C7.70 05/24/95 2 SPM 0968-4 4 C-H C7.70 05/24/95 2-VP-001 1

2-SPM-072A-2-1 C-H C7.70 03/30/95 l

i Docket Number: 50-339 Serial Number: 96-629 Page 17 of 20 2-PT-48 Visual Inspection of ASME Class 1 Pressure Boundary Components.

The examinations were completed on 9/10/96.

The following is a summary of the reportable indications and corrective actions.

2-RC-MOV-2593 Packing leak.

The packing was adjusted under. Work Order 350641-01.

2-RC-HCV-'2557A Packing leak.

The packing was adjusted under Work Order 350537-01.

2-RC-HCV-2556A Boric acid crystals at the body to bonnet interface.

The bonnet studs were examined and found to be acceptable. The body to bonnet gasket was replace under Work Order 350536-01.

2-RH-MOV-2720B Boric acid crystals at the body to bonnet interface. The. body.to bonnet gasket and fasteners were replaced under Repair / Replacement Program 96-359, Work Order 351033-01.

2-RH-MOV-2701 Packing leak. The packing was adjusted under Work Order 329184-02.

2-PT-48.1 Visual Inspection of ASME Class 2 Pressure Boundary Components Inside Reactor Containment. The examinations were completed on 9/10/96.

The following is a summary of the reportable indications and corrective actions.

2-RH-8 Boric acid crystals at the body to bonnet interface.

The studs and nuts were removed, i

cleaned, examined and found to be acceptable, and reinstalled with a new gasket under Work Order 350625-03.

2-RH-19 Boric acid crystals at the body to bonnet interface.

The studs and nuts were removed, i

cleaned, examined and found to be acceptable, and reinstalled with a new gasket under Work Order L

350625-04.

2-RH-24 Boric acid crystals at the body to bonnet interface.

The studs and nuts were removed, cleaned, examined and found to be acceptable, and reinstalled with a new gasket under Work Order 350625-01.

2-RH-30 Boric acid crystals at the body to bonnet e

interface.

The studs and nuts were removed, i

cleaned, examined and found to be acceptable, and j

reinstalled with a new gasket under Work Order 350625-02.

Docket Number: 50-339 Serial Number: 96-629 Page 18 of 20 2-PT-48.1 Continued 2-RH-31 Packing leak.

The packing was adjusted under Work Order 350542-03.

2-RH-HCV-2758 Packing leak.

The packing was replaced under Work Order 350849-01.

2-CH-RV-2382A Boric acid build up on the adjustment screw. The valve was rebuilt under Work Order WO 348503-02.

Snubber Replacements Small Bore Snubber Testing l

A total of 93 small bore snubbers were replaced as part of the Tech. Spec.

Functional test program. Out of the 93 small bore snubbers tested there i

were no functional test failures.

Due to functional test failures in previous refueling outages, two snubbers had to be removed for retest. Out of the two snubbers tested there were no functional test failures.

Due to a visual discrepancy on 2-FW-HSS-205 (the fluid reservoir was empty due to a crack), this small bore snubber was removed for functional testing to prove operability. This snubber successfully passed functional testing.

Small bore snubber removal and installation for the Tech. Spec. Functional testing and the visual inspection programs are considered maintenance activities and not ASME Section XI repairs and replacements. The ANII was not involved in the review of this work.

Large Bore Snubber Testing Large bore snubbers, 2-RC-HSS-1A and 2-RC-HSS-11A, were tested in-place using an API Machine as part of the Tech. Spec. Functional test program. A functional failure occurred on the first snubber tested, 2-RC-HSS-11A. The snubber failed to lock-up in either direction. Snubber 2-RC-HSS-1A was tested and failed due to no lock-up in compression. The snubber was tested again and did pass but would not maintain oil pressure after the test.

Snubber 2-RC-HSS-11A was removed and benched tested and failed to lockup in the tension direction. This snubber was classified as functional failure and it was conservatively assumed that the problem was a manufacturing or design defect, thus the remaining ten large bore snubbers and six spares were functionally tested. The results of the functional testing is summarized below in the order of testing. All testing was performed using the API Machine except were noted:

1.

2-RC-HSS-11A - Failed to lock-up in either direction on the API Machine. Lockup was achieved in the compression direction when bench tested but failed to achieve lock-up in the tension direction. Snubber was replaced with a spare under Repair / Replacement Program 96-374.

l

l Docket Number: 50-339 Serial Number: 96-629 Page 19 of 20 l

2, 2-RC-HSS-1A - Failed to lock-up in the compression direction. The snubber was retested one day later and the compression activation test achieved lock-up based on the ability to achieve bleed rate but flow l

drop-off was not evident in the trace. The piston seal leaked excessively when the snubber was repressurized. Snubber was replaced with a spare under Repair / Replacement Program 96-387.

3.

2-RC-HSS-3A - Failed to achieve an acceptable bleed rate in the compression direction until the third test. Snubber was replaced under Repair / Replacement Program 96-391.

4.

Spare 1000 Kip snubber serial number 4 - Failed to achieve an acceptable lock-up in compression.

5.

2-RC-HSS-10C - Passed all functional test criteria.

6.

Spare 1900 Kip snubber serial number 6 - Passed all functional test criteria. Snubber was installed in location 2-RC-HSS-1A under Repair / Replacement Program 96-387.

7.

Spare 1000 Kip snubber serial number 10 Passed all functional test criteria. Snubber was installed in location 2-RC-HSS-11A under Repair / Replacement Program 96-374.

8.

2-RC-HSS-3C - The snubber was found to be depressurized. The pressure loss was determined to be through the fittings since there was no fluid loss. The snubber passed all functional test criteria.

9.

2-RC-HSS-11C - Passed all functional test criteria.

10.

2-RC-HSS-1C - Failed to achieve lock-up in the compression direction.

Snubber was replaced under Repair / Replacement Program 96-421 Rev.

1.

11.

2-RC-HSS-10B - Passed all functional test criteria.

12.

2-RC-HSS-1B - Passed all functional test criteria.

13.

2-RC-HSS-11B - Passed all functional test criteria.

14, 2-RC-HSS-3B - Passed all functional test criteria.

15.

2-RC-HSS-10A - Passed all functional test criteria.

16.

Spare 1900 Kip snubber serial number 9 - Passed all functional test criteria. Snubber was installed in location 2-RC-HSS-3A under Repair / Replacement Program 96-391.

17.

Spare 1900 Kip snubber serial number 5 - Passed all functional test criteria. Snubber was installed in location 2-RC-HSS-1C under Repair / Replacement Program 96-421 Rev.

1, 18.

Spare 1000 Kip snubber serial number 9 - Failed to meet lock-up acceptance criteria in both directions.

The failed snubber from 2-RC-HSS-11A was removed and disassembled. Metal shavings were found under the valve, piston ports, and in 7 out of the 16 valve springs. The shavings were analyzed by a semi-quantitative elemental analysis (by energy dispersive spectroscopy, EDS). This analysis indicated that the shaving material was consistent with stainless 15-SPH, which is the same grade of stainless steel used in the snubber. The aluminum / bronze valve seating surface had indications where the valve attempted to close and crushed the stainless shavings into the seating surface. It is presumed that this material may have been trapped under the valve since construction based on the size and shape. The shavings most likely were left from drilling the tapped shallow holes for the 16 springs. It was also noted that the thermal compensator (made of Hytrel manufactured by DuPont) was loose fitting around the ring. The thermal compensator adjusts the valve

Docket Number: 50-339 Serial Number: 96-629 Page 20 of 20 setting for various temperatures such that the lock-up rate remains constant. A representative from Taylor Devices, Inc. contacted an engineer from DuPont who confirmed this material can swell 1% but the material reported stabilizes. The swelling is obviously caused by oil submersion due to the fact that a spare that has never been in service had the same condition.

The failed snubber from 2-RC-HSS-1A was removed and disassembled. A metal shaving was found in 1 of the 16 springs. The piston seals were found to be damaged which explains the leak when the snubber was repressurized. This type of seal damage most likely occurred during the in-place functional testing based on the fact that the snubber was found fully pressurized and did not begin to leak until after the testing.

The failed snubber from 2-RC-HSS-3A was removed and disassembled. A very small piece of metal was found adjacent to the tension side area of the piston, adjacent to the tension valve. The valve face had minor indications.

Spare 1000 Kip snubber serial number 4 was disassembled. A single fragment of stainless steel was found embedded in one of the valves. There was no l

other evidence of foreign material in this snubber although there were a l

couple of small indications in the valve face. A seal rebuild report on l

this snubber from October 1991 reported that " metal shavings and chips were l

found on the interior walls of the cylinder and the cap nut-to-cylinder interface" and that " red adhesive tape and small particles were found embedded in the guide ring wiper and metal guide ring on the front (rod end) cylinder cap". It is likely that the fragment embedded in the valve face occurred prior to the rebuild and not during this round of testing.

I l

The failed snubber from 2-RC-HSS-1C was removed and disassembled. No i

foreign material was found in this snubber.

Spare 1000 Kip snubber serial number 9 was disassembled. The tension face had two small indications in the valve and metal shavings were found stuck in three of the eight springs. The compression face had five indications in the valve face and no shavings were found in the springs or on this side of the piston. A small piece of metal was found embedded in the guide ring.

I The stainless steel shavings found in snubber 2-RC-HSS-11A were determined l

to be left from the manufacturing process. Other snubbers also had small l

metal shavings. All installed snubbers had an acceptable as-left functional test. Virginia Electric and Power Company is assessing plans to replace all large bore snubber during the next refueling outage with a different design.

i.

i i

j i

j ATTACHMENT 2 i

1 l

{

1996 UNIT 2 REFUEUNG OUTAGE i

i INSERVICE INSPECTION

SUMMARY

REPORT i

i i

OWNER'S REPORT OF REPAIRS AND REPLACEMENTS i

4 4

NORTH ANNA POWER STATION - UNIT 2 P.O. BOX 402 MINERAL, VA 23117 COMMERCIAL SERVICE DATE 12-14-80 VIRGINIA ELECTRIC AND POWER COMPANY 5000 DOMINION BOULEVARD GLEN ALLEN, VA 23060

Docket Number: 50-339 Serial Number: 96-629 Page 1 of 68 Renairs and Reolacements Repairs and replacements completed during this inservice inspection period were performed in accordance with Section XI of the ASME Boiler and Pressure Vessel Code, 1986 Edition.

1 The following paragraphs and the attached NIS-2 Forms (Attachment 2, pages 6 through 68) represent those repairs and replacements performed on Class 1 or Class 2 systems:

Replaced charging pump head assembly and associated bolting on 2-96-175 CH-P-1A in accordance with Design Change Package 95-216, Class 2 (Work Order 339337-01). The replacement was completed on 8/27/96.96-181 - Replaced one stud and two nuts on pressurizer safety valve 2-RC-SV-2551B inlet flange, Class 1 (Work Order 327415-01). The replacement was completed on 9/22/96.96-184 - Replaced four studs and eight nuts on the inlet flange bolting on 2-MS-SV-201B, Class 2, (Work Order 327374-02). The replacement was completed on 9/24/96.96-185 - Replaced three studs and six nuts on the inlet flange bolting on l

2-MS-SV-201C, Class 2, (Work Order 327375-02). The replacement l

was completed on 9/24/96.96-187 - Replaced two studs and four nuts on the inlet flange bolting on l

2-MS-SV-202B, Class 2, (Work Order 327377-02). The replacement was completed on 9/24/96.

l 96-188 - Replaced two studs and four nuts on the inlet flange bolting on j

2-MS-SV-202C, Class 2, (Work Order 327378-02). The replacement was completed on 9/23/96.

l I

96-191 - Replaced two studs and four nuts on the inlet flange bolting on 2-MS-SV-203C, Class 2, (Work Order 327381-02). The replacement was completed on 9/23/96.96-193 - Replaced one stud and two nuts on the inlet flange bolting on 2-MS-SV-204B, Class 2, (Work Order 327383-02). The replacement was l

completed on 9/24/96.96-196 - Replaced two studs and four nuts on the inlet flange bolting on 2-MS-SV-205B, Class 2, (Work Order 327386-02). The replacement was completed on 9/24/96.96-197 - Replaced four studs and eight nuts on the inlet flange bolting on 2-MS-SV-205C, Class 2, (Work Order 327387-02). The replacement was completed on 9/23/96.

i Docket Number: 50-339 Serial Number: 96-629 Page 2 of 68 96-205 - Replaced manway diaphragm and manway on refueling water' storage tank 2-QS-TK-1, Class 2, (Work Order 338814-01). The replacement was completed on 9/23/96.96-206 - Replaced manway diaphragm on recirc. spray tank 2-RS-TK-1, Class 2,

(Work Order 338814-02). The replacement was completed on 9/23/96.96-252 - Replace body to bonnet studs.and nuts on 2-SI-1, Class 2, (Work Order 340565-01). The replacement was completed on 9/19/96.96-282 - Replaced body to bonnet studs and nuts on 2-MS-PCV-201A, Class 2, (Work Order 345916-01). The replacement was completed on 8/8/96.96-288 - Replaced reducing couplings and pipe caps on 2-SI-LT-2920, 2992, l

2924, 2926, 2928, and 2930 in accordance with Design Change-Package 94-017, Class 2 (Work Orders 339831-01, 339833-01, and 339834-01). The replacement was completed on 9/22/96.96-289 - Replaced one handhole bolt on 2-RC-E-1A, Class 2, (Work Order j

339464-02). The replacement was completed on 9/12/96.

l 96-292 - Replaced two primary manway studs on 2-RC-E-1B, Class 1, (Work Order 339223-03). The replacement was completed on 9/16/96.96-294 - Modified existing pipe support for 2-SI-HSS-808 for 1/2" and 1".

leakoff lines in accordance with Design Change Package 94-102, Class 2, (Work Order 347464-01). The replacement was completed on 9/10/96.

l-96-295 - Modified existing pipe support for 2-RS-R-608 for 1/2" and 1" leakoff lines in accordance with Design Change Package 94-102, Class 2, (Work Order 347464-02). The replacement was completed on 9/10/96.

l 96-316 - Replaced bolting on 2-QS-TE-200B, Class 2, (Work Order 341174-l 19). The replacement was completed on 9/17/96.

i 96-321 - Replaced the body to bonnet studs and nuts on 2-RC-HCV-2556C, Class 1, (Work Order 350604-01). The replacement was completed on 9/20/96.96-330 - Replaced the body to bonnet studs and nuts on 2-QS-TE-200A, Class 2,

(Work Order 341174-18). The replacement was completed on 9/18/96.96-331 - Removed and reinstalled 2-FW-62 after seat repair, Class 2, (Work i

Rev. 2 Order 350519-04). The replacement was completed on 10/14/96.

t I

Docket Number: 50-339 Serial Number: 96-629 Page 3 of 68 96-336 - Repaired a 3/4" indication on 3/4" pipe connecting 2-RC-203 found during an augmented inspection, Class 1, (Work Order 350956-01).

The repair was complete on 9/16/96.96-337 - Replaced the body to bonnet bolting on 2-QS-43, Class 2, (Work Order 341174-13). The replacement was completed on 9/17/96,96-339 - Replaced the body to bonnet bolting on 2-QS-68, Class 2, (Work Order 341174-12). The replacement was completed on 9/17/96.96-352 - Replaced the body to bonnet bolting on 2-QS-37, Class 2, (Work Order 351036-01). The replacement was completed on 9/18/96.96-353 - Replaced valve body to bonnet bolting on 2-QS-40, Class 2, (Work Order 351037-01). The replacement was completed on 9/18/96.96-357 - Machined gasket seating surface on 2-FW-62 to allow proper seating of disk, Class 2, (Work Order 350519-01). The repair was completed on 9/18/96.96-358 - Repaired valve seat to restore design dimensions for 2-MS-SV-203B, Class 2, (Work Order 327380-01). The repair was completed on 9/17/96.96-359 - Replaced the body to bonnet bolting on 2-RH-MOV-2720B, Class 1, (Work Order 351033-01). The replacement was completed on 9/19/96.96-360 - Replaced the body to bonnet bolting on 2-CC-302, Class 2, (Work Order 350962-01). The replacement was completed on 9/23/96.96-361 - Replaced the body to bonnet bolting on 2-CC-289, Class 2, (Work Order 350963-01). The replacement was completed on 9/27/96.96-362 - Replaced the body to bonnet bolting on 2-CC-276, Class 2, (Work Order 350961-01). The replacement was completed on 9/27/96.96-363 - Machined gasket seating surface on 2-FW-94 to allow proper seating of disk, Class 2, (Work Order 350524-01). The repair was completed on 9/19/96.96-364 - Removed and reinstalled 2-FW-126 after seat repair, Class 2, j

Rev. 1 (Work Order 350824-01). The replacement was completed on 9/26/96.96-365 - Removed and reinstalled 2-FW-126 after seat repair, Class 2, Rev. 1 (Work Order 350824-01). The replacement was completed on 9/26/96,96-370 - Machined gasket seating surface on 2-FW-126 to allow proper I

seating of disk, Class 2, (Work Order 350824-01). The repair was l

completed on 9/19/96.

l

Docket Number: 50-339 Serial Number: 96-629 Page 4 of 68 96-372 - Replace body to bonnet nuts on 2-SI-MOV-2867D, Class 2, (Work Order 351217-02), The replacement was completed on 9/20/96.96-373 - Performed weld buildup on outside of valve body of 2-FW-62, Class Rev. 1 2,

(Work Order 350519-06). The repair was completed on 10/2/96.96-374 - Replace large bore snubber, 2-RC-HSS-011A, and one cap screw, Class 1, (Work Order 351094-01). The replacement was completed on 9/22/96.96-378 - Performed weld buildup on outside of valve body of 2-FW-94, Class Rev. 1 2,

(Work Order 350524-05). The repair was completed on 9/22/96.96-379 - Performed weld buildup on outside of valve body of 2-FW-126, Rev. 1 Class 2, (Work Order 350824-04). The repair was completed on 10/2/96.96-380 - Installed alignment lugs on adjacent piping, 16"-FW-424-601-Q2, Rev. 2 to aid in the installation of check valve, 2-FW-62, Class 2, (Work Order 350519-07). Lugs were removed ~after installation. The replacement was completed on 9/23/96.96-381 - Installed alignment lugs on adjacent piping, 16"-FW-423-601-02, Rev. 2 to aid in the installation of check valve, 2-FW-94, Class 2, (Work Order 350524-06). Lugs were removed after installation. The replacement was completed on 9/23/96.96-382 - Installed alignment lugs on adjacent piping, 16"-FW-422-601-Q2, Rev. 2 to aid in the installation of check valve, 2-FW-126, Class 2, (Work Order 350824-05). Lugs were removed after installation. The replacement was completed on 9/25/96,96-383 - Replaced the body to bonnet studs on 2-CH-MOV-2286B, Class 2, (Work Order 323638-02). The replacement was completed on 9/19/96.96-385 - Replaced valve, 2-CH-262, and repaired indications and gouges in Rev. 3 adjacent piping, Class 1, (Work Order 351260). The work was completed on 10/12/96,96-387 - Replace large bore snubber, 2-RC-HSS-001A, Class 1, (Work Order 338732-02). The replacement was completed on 9/21/96,96-391 - Replace large bore snubber, 2-RC-HSS-003A, Class 1, (Work Order 351110-03). The replacement was completed on 9/28/96.96-395 - Installed bushing on load stud for snubber 2-RC-HSS-639.01, found missing during reinstallation from functional testing, Class 1, (Work Order 351458-01). The replacement was completed on 9/26/96.

Docket Number: 50-339 Serial Number: 96-629 Page 5 of 68 96-396 - Installed bushing on load stud for snubber 2-RC-HSS-638.01, found missing during reinstallation from functional testing, Class 1, (Work Order 351459-01). The replacement was completed on 9/26/96.96-397 - Installed bushing on load stud for snubber 2-RC-HSS-637.06, found missing during reinstallation from functional testing, Class 1, (Work Order 351460-01). The replacement was completed on 9/26/96.96-398 - Installed bushing on load stud for snubber 2-RC-HSS-637.02, found missing during reinstallation from functional testing, Class 1, (Work Order 351461-01). The replacement was completed on 9/26/96.96-399 - Performed weld buildup on inside of valve 2-FW-94 to allow Rev. 1 machining without violating the minimum wall requirements, Class 2,

(Work Order 350524-05). The repair was completed on 9/25/96.96-421 - Replaced large bore snubber, 2-RC-HSS-001C, and one cap screw, Rev. 1 Class 1, (Work Order 351737-01). The replacement was completed on 9/25/96.96-423 - Replaced body to bonnet bolting on 2-SI-140, Class 2 (Work Order 350663-03). The replacement was completed on 9/28/96.96-424 - Cut, removed, and reinstalled pipe support 2-SI-R-5 on 12050-WMKS-104C-2, to remove 2-SI-MOV-2862B, Class 2, (Work Order 351779-03). The replacement was completed on 10/1/96.

I 96-428 - Replaced body to bonnet bolting on 2-QS-MOV-202A, Class 2 (Work Order 350813-01). The replacement was completed on 9/30/96.96-429 - Replaced body to bonnet bolting on 2-QS-MOV-202B, Class 2 (Work l

Order 350813-02). The replacement was completed on 9/26/96.96-435 - Replaced body to bonnet bolting on 2-CH-MOV-2287B, Class 2 (Work Order 351748-01). The replacement was completed on 9/28/96.96-445 - Removed excess metal from back and side of valve disc to prevent binding of 2-SI-119, Class 1, (Work Order 352438-01). The repair was completed on 10/4/96.96-448 - Rebuilt valve, 2-CH-RV-2382B, and replaced valve disc and nozzle, Class 2, (Work Order 352487-05). The replacement was completed on 10/6/95.

_ _ ~ -

Dockst Number: 50-339 Serial Number: 96-629 Page 6 of 68 FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1, Owner Y(AA bkte rk k cLA/ (emocW Date 9-30 'l0 a

nome i

cm'nion b\\V]. (-!m All<m \\lA tse4 e 1

Se CD

Shee, of 1

Address

/

2. Plant No b4A 8"l4 I b b 6"

Unit 1

uom.

P0. 6e v Wo t hiner \\

\\/A 1s n, Kit 9(-l'E w o. oeWl331-on oc.P W-2i(

Adhroes Repelr O/senization P.O. No., Job No., etc.

3. Work Performed by rah be nt k et.,t( (om T pe Code Symbol Stamp A

/

Authorization No.

FN icec bn W nta.m b V.

An A in A neto Expir. tion oste

'vA.

Address

/

rs H)

4. Identification of System (Mt d

0 U m e- (o w W & ASME P pet4 Wln. Co A c,

'I'9 6 ^t A c i A 3).7 is 4

Edition, 19 7o
Addenda,

{ IK Code Case

]

5. (a) Applicable Construction Code (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 R6 EA(hew
6. Identification of Components Repaired or Replaced and Replacement Components

)

ASME Code National

Repaired, Stamped Name of Name of Manufacturer Board Other Year
Replaced, (Yes Component Manufacturer Serial No.

No.

Identification Built or Replacement or No) l d/-

1-cH-P-I A l*l? 6 P<9lutmed'%

)

De s4<

(

L k NwI 4y M/A.,

1-(%-f-/A l9C( kp A/O l

g,mg

  1. p'Sb1 (ubn~l HDg d/4 2.-cH - P-I A 19 % ll kam<d Alo A

p N N'

^/4 1-c9 -P- / A 19 %

Pe / Aii Al A4G Lv.

fle tmed No k

7c

7. Descripr'.on of Woik

< r iaat e oto m c4 ov e-rs EN A'3 5 e u em

<AS5ct'iw e

,so kn a

1 0 Jl 1

J J

8. Tests Conducted: Hydrovstic 0 Pneumatic Nominal Operating Pressure Other O Pressure.1To C psi Test Temp.

I30

  • F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) Informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82)

This Form (E00030) may be obtained from the Order Dept., ASME,345 E.47th St., New York, N.Y,10017

1 FORM NIS-2 (Back)

SME dwss 2.,

9. Remarks Applicabla Manufacturer's Data Reports to be attached i

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this red cmh conforms to the rules of the ASME Code,Section XI.

repair or replacement

,/h Type Code Symbol Stamp Y

Certificate of Authorization No.

2 Expiration Date 7

E%E bu Mt I Date W

36 gg 9(

Signed e

Owner or owner's Desiensis, Title y

J CERTIFICATE OF INSERVICE INSPECTION I

1, tha undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Y/

  • E and employed by
  1. 182"I of N'MleN!. d7 have inspected the components described in this Own'er's Report during the period M?//h 8/27!#/

to

. and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

I By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinat.ons and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

N*

5-Commissions VAYAY LHA inspector's Signature National Board, State, Province, and E ndorsements l

8pt'M !

19 N Date i

t j

i l

Dockat Number: 50-339 Serial Number: 96-629 Page 7 of 68 i

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Virginia Electric & Power Company September 25,1996 Name 5000 Dominion Blvd., Glen Allen, VA 23060 1

1 3

g Address J

2. Plant North Anna Power Station 2

Unit Name P.O. Box 402, Mineral, VA 23117 R/R 96-181 W.O. 327415-01 Address Repelt Oreenization P.O. No., Job No., etc.

3. Work Performed by Virginia Electric & Power Company N/A Typ M SymW Step Name N/A Aut riz on No, 5000 Dominion Blvd., Glen Allen, VA 23060 nm i

Expiretion Date Address 4

eactor Coolant i

4. Identification of System
5. (a) Applicable Construction Code ANSI B31.7 69 Editisn,1970 Addenda, 78. 81,83W 11h Case gg 6

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19

6. Identification of Components Repaired or Replaced and Haplacement Components i

j ASME Cod.

National

Repaired, Stamped Nome of Name of Manufacturer Board Other Year
Replaced, (Yes 1

Component Manufacturer Serie: No.

No.

Identification Built or Replacement or No) i Stud Structural, Unknown Unk nown N/A 2 RG-5V-2 5 51 D Unk.

Replaced No 4

13/8" Dia.

Nut, Unknown Unknown N/A 2-RG-5V-2 b b l B Unk.

Neplaceo No 1 3/8" Dia.

Stud Structual, Mackson, Inc.

Heat No.

N/A 2-HC-bV-2 D D 1 t5 1UUU Meplacement no 13/8" Dia.

8098419

Nut, Mackson, Inc.

Heat No.

N/A 2-RESV-25518 1996 Replacement No 13/8" Dia.

29329MY f

7. Description of Work Replace one stud and two nuts - found to be unsat when relief valve was removed for testing.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other] Pressure psi Test Temp.

'F NOTE: Supplemental sheets m form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) Informs.

i tion in items 1 through 6 on this report is included on sech sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82)

This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017

FORM NIS.2 (Back)

9. Remarks ASME Class 1 Applicable Manufacturer's Data Reports to be etteched Performed ASME Section XI preservice VT.1 r

CERTIFICATE OF COMPLIANCE We certify that the statements made lo the report are correct and this reolacement conforms to the rules of the I

ASME Code.Section XI.

1 Type Code Symbol Stamp N/A N/A N/A Certificate of Authorization No.

Expiration Date Signed IC b'W SteINIsb 2f gg %

Dwner et owners'besiones, Titse Date CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State I

or Province of YMe s **

and employed by # '#'8'A *I-of

  1. eWo *.I 4

have n ted the components described in this Owner's Report during the period 3/zc/Pt 9 zz It and state that to l

to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shell be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions MY2 V

  1. MM er r

inspector s Signature National Board, $ tate! Province, and E ndorsements Date

]u Z.Y 1g fd a

i a

8 4

e e

DockOt Numbers 50-339 Serial Number: 96-629 Page 8 of 68 FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI i

I Virginia Electric & Power Company October 2.1996 Nome 5000 Dominion Blvd., Glen Allen, VA 23060 Sheet of Addreas

{

2. Plant North Anna Power Station Unit 2

Nome P.O. Box 402, Mineral, VA 23117 R/R 96-184 W.O. 327374-02 Addrous Repair Organization P.O. No., Job No., etc.

3. Work Performed by Virginia Electric & Power Company N/A Type Code SymW Sep Name N/A Aut rization No.

5000 Dominion Blvd., Glen Allen, VA 23060 nm Expiration Date ain Steam

4. Identification of System
5. (a) Applicable Construction Code ANSI B31.7 69 Edition]970 Addenda, 78, 81, 83(R),11 Q gg 6

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19

6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National
Repaired, Stamped Name of Name of Manufacturer Board Other Year
Replaced, (Yes Component Manufacturer Serial No.

No.

Identification Built or Replacement or No)

Stud Structural, aknown Unknown N/A 2-Ms-sV 2Dl p Unk.

Replaced No 1 3/8* Dia.

Nut, Unknown Unknown M/A 2-Ms-sv-2Dl p unk.

Neplaceo no 13/8' Dia.

I Stud Structual.

Mackson, Inc.

Heat No.

N/A 2-M5-bV-ZUl u luvo Neplacement no j

13/8" Dia.

8098419

Nut, Nova Machine Heat No.

N/A 2-MS-SV-2018 1993 Replacement No 1 3/8" Dia.

Products H2L 4

7. Description of Work Replaced four studs and eigM nuts on the inlet flange botting after testing. Good maintenance practice.
8. Tests Conducted: Hydrostatic Pneumatic 0 Nominal Operating Pressure O Other O Pressure psi Test Temp.

'F NOTE: Supplemental sheets in form of lists, sketches, or drawings rney be used, provided (1) size is 8% in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82)

This Form (E00030) may be obtained from the Order Dept., ASME,345 E,47th St., New York, N.Y.10017

._ _.. _ _. - _.. _ _. _ _.. _ _ _.. _.. _ _ _ _ ~ _. _ - - _. = _ _. _ _ _..... _...__

m FORM NIS 2 (Back)

9. Remarks ASME Class 2 Applicable Manufacturer's Data Reports to be attached l

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this roolecment conforms to the rules of the ASME Code, Section Xl.

'***i'**'***'"*"'

Type Code Symbol Stamp N/A N/A

'^

Certificate of Authorization No.

Expiration Date b

IN Ed*

Date de E

19 I(r Signed Owner or @rner's Des (nee. Title CERTIFICATE OF INSERVICE INAPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of VW. *d and employed by M J' # M of den /a */ CT have inspected the components described in this Owner's Report during the period MME MMA to and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Nd A*

Commissions VA V1V

.ZA A Inspector's Signature National poord,' St'ste, Province, and E ndorsements Date AIJ 19 Ps

Dockst Number: 50-339 Serial Number: 96-629 Page 9 of 68 FORM NIS.2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions t ' the ASME Code Section XI

=

Virginia Electric & Power Company October 2,1996 Name 5000 Dominion Bhrd., Glen Allen, VA 23060 1

1 3

Address

2. Plant North Anna Power Station 2

Unit Name P.O. Box 402, Mineral, VA 23117 R/R 96-185 W.O. 327375-02 Address Repair Organization P.O. No., Job No., etc.

3. hk Performd W rginia Electric & Power Company N/A TmMSWSW 5000 Dominion Blvd., Glen Allen, VA 23060 Authorization No.

Expiration Date 1

Address

4. Identification of System
6. (a) Applicable Construction Code ANSI B31.7 69 39
Edition, Addenda, Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19
6. Identification of Components Repelred or Replaced and Replacement Components ASME Code National
Repaired, Stamped Name of Name of Manufacturer Board Other Year
Replaced, (Yes Component Manufacturer Serial No.

No.

Identification Built or Replacement or No)

Stud Structural, Unknown Unknown N/A 4-M>D V 4U l b UnK.

ne plaGe g RD 13/8" Dia.

Nut, Unknown Unknown N/A 4-M >bV-4Ul6 un K.

nepiaveu i4v i

13/8" Dia.

~$tud Structual, Mackson, Inc.

neat No.

n/A 4-m>5vdUn.,

ii36

.% pia m i... n inv 13/8" Dia.

8098419 Nut.

Nova Machine Heat No.

N/A 2-MS-5V-201 L; 1UUJ Mapiacement no 13!8" Dia.

Producta H2L

7. Description of Work Replaced three studs and six nuts on the inlet flange botting af ter testing. Good maintenance practice.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure OtherO Pressure psi Test Temp.
  • F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in x 11 in., (2) Informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

M2/82)

This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017

- ~ ~. -

~..

I FORM NIS 2 (Back)

9. Remarks ASME Class 2 Applicable Manufacturer's Date Reports to be ettsched

+

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code,Section XI,

'*D*"**'*****"'

Type Code Symbol Stamp N/A N/A Certificate of Authorization No.

Expiration Date " ^

TM IaTe ate Date d'

k 1 D

Signed.

19 Owner af Owne sCosignes, Title r

CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Y#*mb and employed by I' 8 M of NMs */ C 7" have inspected the components described in this Owner's Report during the period NMft R

. and state that to to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

4 M

Commissions N YM Y

/NA inspector's Signature National Board, State, Province, and Endorsements Date 6e I

19 M l

I I

Dockst Number: 50-339 Serial Number: 96-629 Page 10 of 68 FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Virginia Electnc & Power Company October 2,1996 g,

Name 5000 Dominion Blvd., Glen Allen, VA 23060 1

1 3%

g Addrons

2. Plant North Anne Power Station Unit 2

Name s

P.O. Box 402, Mineraf, VA 23117 R/R 96187 W.O. 327377-02 Addreas Reoeir Orgenlastion P.O. No., Job No., etc.

3. Work Performed by Virginia Electric & Power Company N/A Tm M SmW SW 5000 Dominion Blvd., Glen Allen, VA 23060 A

Empiration Date Address Main Steam

4. Identification of System
6. (a) Applicable Construction Code ANSI B31.7 69 Edition,1970 Addenda, 78, 81, 83(R),11 Q Cm jg (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19
6. Identification of Components Repaired or Replaced and Replacement Components ASME Coda National
Repaired, Stamped Name of Name of Manufacturer Board Other Year
Replaced, (Yes Component Manufacturer Serial No.

No.

Identification Built or Replacement or No)

Stud Structural.

Unknown Unknown N/A 2.M S-SV-202 B Unk.

Replaced No 1 3/8" Dia.

Nut, Unknown Unknown N/A 2 MS-5V 202B Unk.

Heplaceo No 13/8" Dia.

Stud Structual.

Mackson. Inc.

Hest No.

N/A 2-MS-5V ZUZB 1Uvc Neplacement no 13/8" Dia.

8098419

Nut, Nova Machine Heat No.

N/A 2-MS SV 2028 1993 Replacement No 1 3/8" Dia.

Products H2L

7. Description of Work Replaced two studs and four nuts on the inlet flange botting after testing. Good maintenance practice.
8. Tests Conducted: Hydrostatic Pneumatic Nominst Operating Pressure O Other] Pressure psi Test Temp.

'F NOTE: Supplemental sheets in form of lists, sketches, or drawings rney be used, provided (1) size is 8% in. x 11 in., (2) informe-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82)

This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017

)

I I

l FORM NIS-2 (Back)

9. Remarks ASME Class 2 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this. replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A N/A Certificate of Authorization No.

Expiration Date " ^

Signed TT EMNL-Date O 1

19 74 Owner or #wner's DeGgr.se, Title CERTIFICATE OF INSERVICE INSPECTION f, the undersigned, holding a valid comminion issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of NN #* b and employed by U E 7I of i/ce/ A-/ th have inspected the components described in this Owner's Report during the period M#Nr

  1. I 5'dY to

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signin"g this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

N4 N

Commissions YN W V IM A inspector's Signature National Board, State,' Province, and Endorsements Date 8'[ J 19 N

Dockst Numbers 50-339 Serial Number: 96-629 Page 11 of 68 FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Virginia Electric & Power Company October 2,1996 1

r Name 5000 Dominion Blvd., Glen Allen, VA 23060 I

I Sheet of Addreas 2; Plant North Anna Power Station Unit 2

Name P.O. Box 402. Mineral VA 23117 R/R 96188 W.O. 327378-02 Address Repair Orsenization P.O. No., Job No., etc.

3. Work Performed by Virginia Electric & Power Company N/A Type Code Symbol Stamp Name N/A Authorization No.

5000 Domsnion Blvd., Glen Allen, VA 23060 Expiration Date Main Stem

4. Identification of System

)

5. (a) Applicable Construction Code ANSI B31.7 69 Edition;1970 Addenda;~ 78,81,83(R),11Q Case gg 86 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 l
6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National
Repaired, Stamped Name of Name of Manufacturer Board Other Year
Replaced, (Yes Component Manufacturer Serial No.

No.

Identification Built or Replacment or No)

Stud Structural.

Unknown Unknown N/A 2-M5-5V-202G Unk.

Replaced No 1 3/8" Dia.

Nut.

Unknown Unknown N/A 2-MS 5V-202G Unk.

Replaceo No 1 3/8" Dia.

stud Structual, Mackson, Inc.

Heat No.

N/A 2-M5-5V-4U4U 1UUO Meplacement No 13/8" Dia.

8098419 Nut.

Nova Machine Heat No.

N/A 2-MS-SV 202C 1993 Replacement No 13!8" Dia.

Products H2L 7, Description of Work Replaced two studs and four nuts on the inlet flange bolting efter testing. Good maintenance practice.

8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure O Other O Pressure psi Test Temp.

'F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) Informe-i tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82)

This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017

~.

1 FORM NIS-2 (Back)

9. Remarks ASME Class 2 Applicable Manufacturer's Data Reports to be attached l

CERTIFICATE OF COMPLlANCE We certify that the statements made in the report are correct and this roolacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A N/A Expiration Date Signed d

T S2 E Mh 9

Date 0

1 N

19 Owner or #wner's Disiones, Title l

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of V#* e ar *1 and employed by M f A Idf of M** A /s/k &

have inspected the components described in this Owner's Repok during the period TI

(

to M

fl

. and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Mn/ M Commluions V4 W V Ud inspector's Sienature National Board, State! Province, and Endorsements Date Ocf J 1g PC i

l i

i l

1

. ~.

Dockst Numbers 50-339 Serial Number: 96-629 Page 12 of 68 1

FORM NIS-2 OWNER'S REPORT FOR REPAlRS OR REPLACEMENTS g

As Required by the Provisions of the ASME Code Section XI Virginia Electric & Power Company October 2,1996 Name 5000 Dominion Blvd., Glen Allen, VA 23060 1

1 3

g Address

2. Plant North Anna Power Station 2

Unit Name P.O. Box 402, Mineral. VA 23117 R/R 96-191 W.O. 327381-02 Address Repair Oreentration P.O. No., Job No., etc.

3. Work Performed by Virginia Electric & Power Company N/A Type M WM Stg Name N/A Authorl2stion No.

5000 Dominion Blvd., Glen Allen, VA 23060 Address Main Steam

4. Identification of System
5. (a) Applicable Construction Code ANS! B31.7 69 Edition,1970
Addenda, 8, 81, 83W M Q Case 3g (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19
6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National
Repaired, Stamped j

Name of Name of Manufacturer Board Other Year

Replaced, (Yes i

Component Manufacturer Serial No.

No, identification Built or Replacement or No)

Stud Structural, Unknown Unknown N/A 2-Mb-bV-2VJU Unk.

Neplaceo No 13/8" Dia.

Nut, Unknown Unknown N/A 2-Mb-bV 4UJU UnK.

Meplaceu no 13/8* Dia.

~ Stud Structual.

Mack son, Inc.

Heat No.

N/A 2-Mb bV 4UJU 1550 nepleGemern nD 1 3/8" Dia.

8098419

Nut, Nova Machine Heat No.

N/A 2-MS-5V 203G 1933 Repte;ement No 13/8" Dia.

Products H2L

7. Description of Work Replaced two studs and four nuts on the inlet flange bolting after testing. Good maintenance practice.

)

8, Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other O Pressure psi Test Temp.

  • F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) informe-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82)

This Form (E00030) may be obtained f rom the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017

_~.-.. -

s.

i l

i l

l 1

l FORM NIS-2 (Beck)

9. Remarks ASME Class 2 l

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLlANCE We certify that the statements made in the report are correct and this reolacement conforms to the rules of the ASME Code,Section XI.

'***3''''''"*"*

j Type Code Symbol Stamp N/A-Certificate of Authorization No.

N/A N/A Expiration Date Signed O/

TN Mh Data O A

1 Owner orAwner's Odignes, Title

/

' 19 %

CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of YW/*

  • 1 and employed by
    • S 8 I*I of MV /la h C T have inspected the components described MUME in this Owner's Rsport during the period M

f(

to

_ and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Secsion XI.

By sig'ning this certificate neither t'he inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Ort d

Commissions VA D V ENA inspector's signature National Board, State, Province, and E ndorsements Date 8 ( I _f Ig ft"

Dockst Numbers 50-339 Serial Number: 96-629 Page 13 of 68 FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Virginia Electric & Power Company October 2,1996

1. Owner Date Name 5000 Dominion Blvd., Glen Allen, VA 23060 1

1 Addreas

2. Plant North Anna Power Station Unit Nome P.O. Box 402, Mineral, VA 23117 R/R 96193 W.O. 327383-02 Address Repelt Oreentzetion P.O. No., Job No., etc.
3. Work Performed by Virginia Electric & Power Company N/A Type Code Symbol Stamp Name nfg Authorization No.

5000 Dominion Blvd., Glen Allen, VA 23060 Expiration Date

4. Identification of System
6. (a) Applicable Construction Code ANSI B31.7 gg 9 _ Edition,19 0
Addenda, Code Case 6

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19

6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National
Repaired, Stemped Name of Name of Manufacturer Board Other Year
Replaced, (Yes Component Manufacturer Serial No.

No.

Identification Built or Replacement or No) l 5tud Structural, Unknown Unknown N/A 4-ML-DV 4U90 UnK.

Meplacea rio 13/8" Dia.

Nut.

Unknown Unknown N/A 4 M&bV-4V95 UnK.

rieplageo no 13/8" Dia.

-Stud Structual, Mackson, inc.

Heat No.

RWA 4 -MD-D V-4 V9 D EUhD nupis L umu m n' u 13/8" Dia.

8098419

Nut, Nova Machsne Heat No.

N/A 2-M S-5 V-2045 1UUJ Meplacement No 13/8" Dia.

Products H2L

7. Description of Work Replaced one stud and two nuts on the inlet flange botting after testing. Good maintenance practice.
8. Tests Conducted. Hydrostatic 0 Pneumatic Nominal Operating Pressure O Other Pressure psi Test Temo.

'F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in, a 11 in., (2) Inforrne.

tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82)

This Form (E00030) may be obtained f rom the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017

4 FORM NIS-2 (Back)

9. Remarks ASME Class 2 Applicable Manufacturer's Date Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made irt the report are correct and this replacement conforms to the rules of the ASME Code,Section XI.

N/A Type Code Symbol Stamp N/A

^

Certificate of Authorization No.

Expiration Date Signed -

Wd^

N EMENr Date de 1

19 94

' Owner /r Owner'stosynee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, hold,ing a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of M'ecmE and employed by

  1. 1RE&

of Nrr/ A / #

have inspected the components described in this Owner's 'Repok during the period MMUd pit'b to

. and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

M 6

u Commissions YA Y2 Y IM 4 anspector's Signature Nationel Board, Stet 6, Prov6nce, and Endorsernents Date 68/ 3 19 # 4 l

DockOt Numbers 50-339 Serial Number: 96-629 Page 14 of 68 FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Virginia E actric & Power Company October 2,1996 Name 5000 Dominion Blvd., Glen Allen, VA 23060 1

1 SW d

Address 2, Plant North Anna Power Station 2

Unit Name P.O. Box 402, Mineral, VA 23117 R/R 96-196 W.O. 327386-02 Address Repair Orpenizetion P.O. No., Job No., etc.

3. Work Performed by Virginia Electric & Power Company N/A Type Code Symbol Stamp g,,

Authorization No.

5000 Dominion Blvd., Glen Allen, VA 23060

~

on Date Address

4. Identification of System ANSI 831.7 69 O

b Case

5. (a) Applicable Construction Code gg
Edition, Addenda, (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 i

l

6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National
Repaired, Stamped Name of Name of Manufacturer Board Other Year
Replaced, (Yes Component Manufacturer Serial No.

No.

Identification Built or Replacement or No)

Stud Structural, Unknown Unknown N/A 4-Mb bV-ZUDU UnK.

Neplaceo no 13/8' Dia.

Nut, Unknown Unknown N/A 2 -Mb-b V-4 U D U UnK.

neplacco nu 13/8" Dia.

Stud Structual, Mackson, Inc.

Heat No.

N/A 4-MD bV 4VDD IUUD nepIa6vmum nu 13/8" Dia.

8098419

Nut, Nova Machine Heat No.

N/A 2-MS SV-205B 1993 Replacement No 13/8" Dia.

Products H2L

7. Description of Work Replaced two studs and four nuts on the inlet flange bolting after testing. Good maintenance practice.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure O Other O Pre >>ure pai Test Tema-

'F NOTE: Supplemental sheets in form of lists, sketches, or drewings mey be used, provided (1) size is 8% in. x 11 in., (2) Informa.

tion in items 1 through 6 on this report is included on sech sheet, and (3) each sheet is numbered and the number of sheets is recorded et the top of this form.

(12/82)

This Form (E00030) may be obtained f rom the Order Dept., ASME,345 E.47th St., New York, N.Y.10017

i I

FORM NIS 2 (Back)

9. Remarks ASME Class 2 Applicable Manufacturer's Date Reports to be attached CERTIFICATE OF COMPLlANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A

^

Expiration Date Signed IN b IM*L"-

J Date O b4L 1 19 IS Owner d owner'(Desiones, Title

{

I CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Med and employed by

  1. E 8 WI a

of Ver// /W have in ted the components described in this Owner's 'Repo't during the period r

M N MJ I

and state that to to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

8.

C M

Commissions V4 W 9 E A' d Inspector's 41snature National Board, State, Province, and Endorsements

~

Date CW3 19 } f

\\

4

DockOt Number: 50-339 Serial Number: 96-629 Page 15 of 68 FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Virginia Electric & Power Company October 2,1996 Name 5000 Dominion Blvd., Glen Allen, VA 23060 1

1 3,

g Addreas

2. Plant North Anna Power Station Unit 2

Name P.O. Box 402, Mineral, VA 23117 R/R 962197 W.O. 327387-02 Address Repelr Orsentzetion P.O. No., Job No., etc.

3. Work Performed by Virginia Electric & Power Company N/A Type Code Symbol Stamp Name N/A Authorization No.

5000 Dominion Blvd., Glen Allen, VA 23060 Address Main Steam

4. Identification of System
6. (a) Applicable Construction Code ANSI B31.7 69 Edition,1970
Addenda, 8, 81, 83 W,11 b Case 39 86 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19
6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National
Repaired, Stamped Name of Name of Manufacturer Board Other Year
Replaced, (Yes Component Manufacturer Serial No.

No.

Identification Built or Replacement or No)

Stud Structural, Unknown Unknown N/A 2 Ms sV-2UDL Unk.

Heplaceo no 1 3/8" Dia.

Nut, Unknown Unknov,n N/A 2 Ms-sV 2Ubb
Unx, Meplacea no 13/8" Dia.

Stud Structual.

Mackson, Inc.

Heat No.

N/A Z-Mb-bV ZUDV lupo neplacemo m nu 1 3/8" Dia.

8098419

Nut, Nova Machine Heat No.

N/A 2-MS-SV 205C 1993 Replacement No 1 3/8

  • Dia.

Products H2L

7. Description of Work Replaced four studs and eight nuts on the inlet flange botting after testing. Good maintenance practice.
8. Tests Conducted: Hydrostatic Pneumatic 0 Nominal Operating Pressure O Other Preuvre pal Test Temp.

'F NOTE: Supplemerrtal sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) Informe, tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82)

This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47tn St., New York, N.Y.10017 l

~. -. ~ - -

s FORM NIS 2 (Back)

9. Remarks AWE Ckss 2 Applicable Manufacturer's Date Reports to be attached I

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this '* PbC*'"*"I conforms to the rules of the ASME Code, Section Xl.

N/A Type Code Symbol Stamp

^

^

Certificate of Authorization No.

Expiration Date Signed IE b l48 k Date d A 1 NA 19 Owner oar)wner's DEstenes, Title CERTIFICATE OF INSERVICE INSPECTION f, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State i

or Province of YrrE**IA and employed by

  1. #< d Al of du/ /=

. //

have inspected the components described j

in this Owner's Report during the period If(

9//TITl to

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

.8v signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any menner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

MdM-Commissions W OV 2NA inspect'or's stoneture Nationel Board, State, Province, and Endorsements Date M.7 19 h i

DockC.t Number: 50-339 Serial Number: 96-629 4

Page 16 of 68 FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Virginia Electric & Power Company September 25,1996 9,

Name 5000 Dominion Blvd., Glen Allen, VA 23060 1

1 Addreen

2. Plant North Anna Power Station Unit Name j

P.O. Box 402, Mineral, VA 23117 R/R 96-205 W.O. 338814 01 Address Repair Orsentration P.O. No., Job No., etc.

3. Work Performed by Virginia Electric & Power Company N/A Type Code Symbol Stamp -

Name Authorization No.

5000 Dominion Blvd., Glen Allen, VA 23060 Date Address Quent:h Spray

4. Identification of System i
6. (a) Applicable Conttruction Code NAS-191, API 650 N/A gg
Edition, Addenda, Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19
6. Identification of Components Repaired or Replaced and Replacement Components 1

ASME Code l

l National

Repaired, Stamped i

Name of Name of Manufacturer Board Other Year

Replaced, (Yes Component Manufacturer Serial No.

No.

Identification Built or Replacement or No)

Diaphram, Unknown Unknown N/A Z Ud ih-i Un K.

6:pageu Nv 1/8" Sheet

Manway, Unknown Unknown N/A 4-Ub-I A-i vnn.

Napiowu Nw 3/4" Plate

Diaphram, Energy 5 teel &

Heat No.

N/A 4-ud-l M i i633 be pia i.w mu m Nw 1/8* Sheet '

Supply 1421661

Manway, Energy Steel &

Heat No.

N/A 2-05 1 K-1 1HWD Neplacement reo 3/4" Plate Supply V30462 1

7. Description of Work Replaced manway and diaphram
8. Tests Conducted: Hydrostatic Pneumatic 0 Nominal Operating Pressure @

a Other O Pressure b*4*wa<- pal Test Temp. 44 <d

'F

=

?

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% In. x 11 in., (2) inforrne-tion in items 1 through 6 on this report is included on each theet, and (3) each sheet is numbered and the number of snects is j

recorded at the top of this form.

(12/82)

Thl Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 4

m

. ~..

. ~.

i 1

i FORM NIS-2 (Back)

9. Remarks ASME Class 2 Applicable Manufacturer's Data Reports to be attached i

l CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this roolacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A N/A Expiration Date Signed d

N N6

  • SeoJ, bu
2. c owner or Owner's D5eisnee, Title Date 3, vs CERTIFICATE OF INSERVICE INSPECTION l, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of YMoN> E<

and employed by- # Je d I#

of Mee*//d*-[

M have inspected the components described in this Owr'wr's Report during the period Mb NYO to

. and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signin~g this certificate neither the inspector nor his. employer makes any warranty, expressed or implied, concerning the c;,.

examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer j

shall be liable in any menner for any personal injury or property damage or a loss of any kind arising from or connected with this Inspection.

4.

N Commissions V4 &

INJ inspector's signature National Board, State,'Prdvince, and Endorsements i

Date Jy/ 2/

19 /t I

Dockst Number 50-339 Serial Number: 96-629 Page 17 of 68 FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Virginia Electric & Power Company September 25,1996 3,

Name 5000 Dominion Blvd., Glen Allen, VA 23060 1

1 SWt M

Addreas

2. Plant North Anna Power Station 2

Urit Name P.O. Box 402, Mineral, VA 23117 R/R 96-206 W.O. 338814-02 Address Repair Orsentration P.O. No., Job No., etc.

3. Work Performed by Virginia Electric & Power Company Type Code Symbol Stamp Name N/A Authorization No.

5000 Dominion Blvd., Glen Allen, VA 23060 Expiration Dete Quench Spray.

4. Identification of System
6. (a) Applicable Construction Code NAS-191, API 650 N/A Edition,N/A Addenda, N/A g

gg 86 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19

6. Identification of Components Repaired or Replaced and Replacement Components ASME Code Nationsi
Repaired, Stamped Name of Name of Manufacturer Board Other Yosr
Replaced, (Yes Component Manufacturer Serial No.

No.

Identification Built or Replacement or No)

Diaphram, Unknown Unknown N/A 2-RS-TK-1 Unk.

Replaced No 1/8" Sheet

Diaphram, Energy Steel &

Heat No.

N/A 2-RS-TK 1 1995 Replacement No 1/8" Sheet Supply 1421661

7. Description of Work Replaced manway esddiaphram -leskage around manway
8. Tests Conducted: Hydrostatic @ Pneumatic Nominal Operating Pressure Other Pressur, AL.wn, psi Test Temp. AMM

'F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82)

This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017

_m m_._

FORM NIS-2 (Back)

9. Remarks ASME Class 2 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE i

We certify that the statements made in the report are correct and this roolacement conforms to the rules of the ASME Code,Section XI.

' * * * ' '"*D'*****"*

]

i Type Code Symbol Stamp N/A

)

i Certificate of Authorization No.

N/A N/A Expiration Date l

Signed N

Tdf 60"#

b'*k 2 S gg 4 Date Owner dr Owner's (festenee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of

//wE and employed by M 1 d M-of Mo-//&/

have inspected the components described in this Owner's Report during the period MN I/2 I 75 to.

_ and state that to the best of my knowledge and belief, the Owner has performed examinations and teken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI, i

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any permnal injury or property damage or a loss of any kind arising from or connected with this inspection.

4 N

Commissions V Y2 Y EM/

Inspector's Signature National Board, State,' Province, and Endorsements Date SU'Y L Y 19 70

Dockst Number: 50-339 Serial Number: 96-629 Page 18 of 68 FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Virginia Electric & Power Company September 26,1996 De Nome 5000 Dominion Blvd., Glen Allen, VA 23060 1

1 g%

Addreas

2. Plant North Anna Power Station Unit 2

Name P.O. Box 402, Msneral, VA 23117 R/R 96-252 W.O. 340565-01 Address Repelr Organization P.O. No., Job No., etc.

3. Work Performed by Virginia Electric & Power Company NA Type Code Symbol Stamp Authorization No.

5000 Dormnion Blvd., Glen Allen, VA 23060 Expiretion Date Addreas

4. Identification of System Safety injection
5. (a) Applicable Construction Code ANSI B31.7 69 Edition,1970 Addenda, 78,81,83(R),11Q %

gg 86 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19

6. Identification of Components Repaired or Replaced and Replacement Components ASME Code Nationet
Repaired, Stamped Name of Name of Manufacturer Board Other Year
Replaced, (Yes Component Manufacturer Serial No.

No.

Identification Built or Replacement orNo)

Stud Structural, Unknown Unknown N/A 2 St 1 Unk.

Replaced No 3!4* Dia.

Nut, Unknown Unknown N/A 2-SI-1 Unk.

Replaced No 3/4" Dia.

' Stud Structual.

Mackson, Inc.

Heat No.

N/A 2 56-1 1996 Replacement No 3/4" Dia.

56678

Nut, Mackson, Inc.

Heat No.

N/A 2.$l-1 1996 Replacement No 3/4' Dia.

16409J1

7. Description of Work Replace bolting
  • Seneral corrosion
8. Tests Conducted; Hydrostatic Pneumatic 0 Nominal Operating Pressure O Other O Pressure psi Test Temp.

'F NOTE: Supplemental sheets in form of lists, sketches, or drowings may be used, provided (1) size is 84 in. x 11 in., (2) informe-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number cf sheets is recorded at the top of this form.

(12/82)

This Form (E00030) may be obtained f rom the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017

FORM NIS 2 (Back)

9. Remarks ASME Class 2 Applicable Manufacturer's Data Reports to be attached l

I CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A N/A N/A Certificate of Authorization No.

Expiration Date Mb Tfl E w e86-Date N d m bes 26 Signed t

19 I4 Owner o(Owner's Ddsiones. Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of Ven<ed and employed by MI8DI of eve Mer/ b have inspected the components described in this Ow'ner's Report during the period 4/2 M YS9bt to

. and state that to the best of my knowledge and belief, the Owner has pertoimed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By sig'ning this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this inspection.

mci N Commissions W YlY lO inspector's Sleneture National Board, Stat 3, Province, and E ndorsements Date 8(M 2&

19 h r

Dock t Numbers 50-339 Serial Number: 96-629 Page 19 of 68 FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. OwnerVkabb buk(it. $c Pei - < rn-mu Da,e n-is-9c Q

Nome I

j como Omue nm Ov). CL der VA u0t e Sh.et 1

of I

' Address

/

i

2. Plant Ne< +

Amm. Pe im < oatsw Unit 1

nom.

@0. bag 407,. b4 (Al. VA m,

R/e W-ini.

Mo.RV M -oi i

Addred f

hoosir or'eenitation P.O. No., Job No., etc.

)

3. Work Perforrned byMfaIwh berkrtt k EnW( (shm Type Code Symbol Stamp 84 0

1 J

Authorization No.

8A Coon Onwhdow No).. b N 21Bla eu.

Expiration Date M

/ Address

/

/

4. Identification of System bk em 3
5. (a) Applicable Construction Code A AISl R319 19]a_ _ Edition, 1976 Addends,D Al 9Id fl 5 Code Case (b) Applicable Edition of Section XI Utillred for Repairs or Replacements 19 8 L 3dikiow
6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National
Repaired, Stamped Name of Name of Manufacturer Board Other Year
Replaced, (Yes Component Manufacturer Serial No.

No.

Identification Built or Replacement or No)

U S Tt/AsBe PMS-RN-2otA Id remd No g

bd

$UA5 bo y[

'y 4

1-hS-ftV-10}d )3*/N te m D

7. Description of Work to are bo ko a

ovi o i ta r.

T v*t' l

J J

8. Tests Conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure O Other Pressure psi Test Temp.
  • F l

l NOTE: Supplemental sheets in form of lists, sketches, or drowings mey be used, provided (1) size is 8% in. x 11 in., (2) informe-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded et the top of this form.

(12/82)

This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 l

l

i l

l l

l FORM NIS 2 (Back)

9. Remarks MS1 Applicable Manufacturer's Data Reports to be attached l

i i

CERTIFICATE OF COMPLlANCE 3 We certify that the statements made 10 the report are correct and tnis (GEAtt%h conforms to the rules of the ASME Code, Section Xl.

'**E''***"'*"'

Type Code Symbol Stamp

/

Certificate of Authorization No Expiration Date Nd

/

/

t ISI b NeM Date ucN 6.

Signed _ own.*r or o n.r. o g. tm.

19 %

d d

n CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of Y/NI"N and employed by #J8D7 of

  1. e Id dI have n ted the components described in this Owne#r's Rhrt during the period M

to

. and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this l

Owner's Report in accordance with the requirements of the ASME Code,Section XI.

l By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any menner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

8 M

Commissions I4 YJ Y 2" MA l

InsoectoPs siensture National Board, State, P'rowl6ce, and Endorsernents Date Av e. /f 1g Pd

/

1

Dock 0t Number: 50-339 Serial Number: 96-629 Page 20 of 68 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1, Owner Viroinia Elactne & Power Comoanv Date October 2.1996 Name Snnn ru~nn suva ni.n an.n VA 91 nan Sheet 1

of 1

Address

2. Plant North Anna Power Station Unit 2

Name W.O. 339834 01 W.O. 339833-01 P n Rnr 407. Mnaral VA 21117 fi!R 98.7am DEP 94-017 W.O. 319811.01 Address Repelr oreenization P.O. No., Job No., etc.

3. Work Perforrned by Vi'ginia Electric & Power Company Type Code Symbol Stamp N/A N/A Authorization No.

5000 Domenion Blvd.. Glen Allen. VA 23060 Empiration Date N/A Address

4. Identification of System c**-.o inar,>aa
5. (a) Applicable Construction Code ANSI B31.7 19 69 Edition 1970 Addende, 78, 81, 83(R),115 Code Caos (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 an
6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National
Repaired, Stemped Name of Name of Manufacturer Board Other Year
Replaced, (Yes Component Manufacturst Serial No.

N o.

Identification Built or Replacement or No)

S.S. Pipe.

Tioga Pipe Heat No.

N/A 2-SI-LT 2920, 2992, 1995 Replacement No 2* Dia.

Supply Co.

V20376 2924.2920,2928, 2930 2' x 1* Reducing.

Dubose National Heat Code. ASL N/A 2-SI-LT.2920, 2992 1996 Replacement No Coupling Energy Services Heat No.

2924.2926.2928, A19471 2930 S.S. Pipe Cap

  • Tioga Pipe Heat Codes N/A 2 SI-LT 2920,2992 1995 Replacement No 2" Dia.

Supply Co.

CW1. DBA, CM2 2924,2926.2928, oatn 7, Description of Work rs, im..

in +.n-d r +rino couolina and oion esos to sucoort installation of new level transmitters.

4-4 Hydrostatic i (g 46

8. Tests Conducted:

Pneumatic Nominal Operating Pressure Other Pressure aan psi Test Temp. A mhi.nt

'F S s on. leskeyc y

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) Informs.

tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82)

This Form (EOL

' nay be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017

- ~. -.

.. _ ~ -

.+......

i FORM NIS 2 (Back)

9. Remarks ASME Class 2 Applicable Manufacturer's Data Reports to be attached Performed PT examinations on replacement welds.

This R/R Program invokes the use of Code Case N-4161.

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repbcoment conforms 'o the rules of the ASME Code, Section X1,

'*****P'***"""'

N/A Type Code Symbol Stamp Certificate of Authorization No.

Expiration Date Signed

/

D E 44*t" Date Ock E

Owrdr or Ow6ers Des 6gnee, Title "

19N CERTIFICATE OF INSERVICE INSPECTION I, the undersigned holding a valid commission issued by the National Board of goiler and Prgssure Vessel Inspectors and the Sta

'0 **

or Province of and employed by of Hartford, CT have inspected the components described in this Owner's Report during the period I* //EI to N

and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any menner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

N N-Commissions W DV fM4 inspectors signature Nat6onal Board, State,'Prov6nce, and Endorsements Date Ce 7 &

19 N

Dockst Numbers 50-339 Serial Ntunber: 96-629 Page 21 of 68 FORM NIS 2 OWNER'S REPORT FOR REPAlRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Virginia Electnc & Power Company October 2,1996 Nome 6000 Dominion Blvd., Glen Allen, VA 23060 1

1 Addream

2. Plant North Anna Power Station 2

Unit Name 2

P.O. Box 402, Mineral, VA 23117 R/R 96 289 W.O. 339464-02 Address Repair Oreenization P.O. No., Job No., etc.

3. Work Performed by Virginia Electric & Power Company N/A Type Code Symbol Stomp Name N/A 6000 Dominion Blvd., Glen Allen, VA 23060 Authorization No.

Expiration Date

4. Identification of System
6. (a) Applicable Construction Code ASME 111 68 gg Edition,W68 Addenda-Code Caos (b) Applicat !e Edition of Section XI Utilized for Repairs or Replacements 19
6. Identification of Components Repaired or Replaced and Replacement Components ASME Code i

National

Repaired, Stamped Name of Name of Manufacturer Board Other Year
Replaced, (Yes Component Manufacturer Serial No.

N o.

identification Built or Replacement or No)

Handhole Bolt, Vitco Nuclear Heat No, N/A 4 nU-t;-1 A 1vui neplacea two 1

  • Dia.

Products M38507 Handhole Bolt, Vitco Nuclear Heat No.

N/A 4-ML-L-1 A IUUI neplacemens ng 1 " Dia.

Products M38507 i

i

7. Description of Work Replaced one handhole bolt - damadged during removal of handhole cover.
8. Tests Conducted: Hydrostatic Pneumatic O Nominal Operating Pressure O OtherO Pressure psi Test Temp.

'F NOTE: Supplemental sheets in form of lists, sketches, or drawings rney be used, provided (1) size is 8% in. x 11 in., (2) Informe-tion in it6ms 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded et the top of this form.

(12/82)

This Form (E00030) me ' be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017

l I

FORM NIS-2 (Back)

9. Remarks ASME Class 2 Applicable Manufacturer's Date Reports to be etteched CERTlFICATE OF COMPLlANCE We certify that the statements made in the report are correct and this reo;acement conforms to the rules of the ASME Code,Section XI.
      1. *D'*****"'

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A N/A Expiration Oate Signed SY T2T FM M e" Date O' M0!

$~

Owner 6r Ownef s Designee, Tide 19 CERTIFICATE OF INSERVICE INSPECTION I, the unoersigned, hol, ding a valid commission issued by the National Board of Boiler and Pressure Vesset vspectora v it the State or Province of hE*4 and employed by N' T B I'2 of

  1. eda-/ (T have inspected the components described in this Owner's Report during the period f

h to 9 1

. and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

. By signing this certificate neither the inspector nor his employer makes any warranty, expr'ssed or implied, concerning the e

examinations and corrective measures described in this Owner's Report, Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

No N.

Commissions YA W Y ZNA inspector's Signature National Board, State,' Province, and E ndorsements Date or / 2 19 P(

Dock 0t Number: 50-339 Serial Number: 96-629 Page 22 of 68 FORM NIS 2 OWNER'S REPORT FOR REPAlRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Virginia Electric & Power Company September 27,1996 Name 5000 Dominion Blvd., Glen Allen, VA 23060 1

1 g

g Addreas

2. Plant North Anna Power Station 2

Unit Name s

'.O. Box 402, Mineral, VA 23117 R/R 96 292 W.O. 339223 03 Addreas Repair orpentzetion P.O. No., Job No., etc.

3. Work Performed by Vi'9'nis Doctne & Power Company N/A Type Code Symbol Stamp,

Name NM Authorization No.

5000 Dominion Blvd., Glen Allen, VA 23060 Expiration Date Address net r tant

4. Identification of System
5. (a) Appiscable Construction Code ANSI B31.7 69 Edition,1970
Addenda, 8, 81, 83W.1 he Caes gg (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19
6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National
Repaired, Stemped Name of Name of Manufacturer Board Other Year
Replaced, (Yes Component Manufacturer Serial No.

No.

Identification Built or Replacement or No) i l

Manway Stud.

Unknown Unknown N/A 2-NU-L-l u Unk.

Neplaceo no j

1 7/8" Dia.

Cold Leg

]

Manway Stud.

Nova Machine Heat No.

N/A 1 NU-L-15 1UU4 neplacement no 17/8" Dia.

Products 89559 Cold Leg

7. Description of Work Replaced two pnmary manway studs - damadged dunng removal of manway.
8. Tests Conducted: Hydrostatic Pneumatic 0 Nominal Operating Pressure O Other O Pressure psi Test Temp.
  • F NOTE: Supplemental sheets in form of lists, tketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) informe.

tion in items 1 through 6 on this report is included on sech sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

i (12/82)

This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017

l 1

FORM NIS 2 (Back)

9. Remarks ASME Class 1 Applicable Manufacturer's Data Maports to be attached Performed ASME Section XI VT 1 preservice examination d

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this rantacament conforms to the rules of the ASME Code,Section XI.

'***i'**'***'"*"'

i I

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A N/A Expiration Date Signed

[M TII E9 * * *?

Date 34*I' d d' U

19 F4 Owner or #wner's Dedense, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of dro ns # 4 and employed by M J U7f of

/ed/* */ (f have inspected the components described in this Ow'ner's' Report during the period IIf!N M/L MO to

_ and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any menner for any personal injury or property damage or a loss of any kind erising from or connected with this inspection, kdI N. -

Commissions V8VJV 2MA i

~

inspector s S6gnature National Board, Stete,' Province, and Endorsements Date Sr's / 27 19-W i

1

Docket Numbers 50-339 Serial Number: 96-629 Page 23 of 68 FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 9, %,

Virginia Electric & Power Company September 27,1996 Date Name 5000 Dominio. Blvd., Glen Allen, VA 23060 sheet 1

of 1

Address

2. Plant North Anna Power Station Unit 2

Name P.O. Box 402, Mineral, VA 23117 R/R 96-294 W.O. 347464-01 DCP 94-102 Adorses Repear oreenization P.O. No., Job No., etc.

3. Mrk Pedormed by Virginia Electric & Power Company Type Code Symbol Stamp N/A Authorization No.

6000 Dominion Blvd., Glen Allen, VA 23060

"#^

Expiration Date Address l

4. Identification of System Safety injection
6. (a) Applicable Construct 6on Code ANSI B31.7 jg 69 Edition,1970 Addenda, 78. 81, 83(R),11 tode Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 86
6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National
Repaired, Stamped j

Name of Name of Manufacturer Board Other Year

Replaced, (Yes I

Component Manufacturer Serial No.

No.

Identification Built or Replacement or Mo)

Pipe Support, N/A N/A N/A 2 SI-HSS-608 Unk.

Replacement No

7. Description of Work Modified existing support for 1/2" and 1" leakoff lines.
8. Tests Conducted; Hydrostatic Pneumatic Nominal Operating Pressure O OtherO Pressure psi Test Temp.

'F NOTE: Supplemental sheets in form of lists, sketches, or drowings may be used, provided (1) size is 8% in. x 11 in., (2) informs.

t!on in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82)

This Form (E00030) may be obtained f rom the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017

FORM NIS-2 (Back)

9. Remarks ASME Class 2 Applicable Manufacturer's Date Reports to be etteched Performed ASME Section XI preservice VT-3 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this r=l= ^ = nt conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A I

U N

Signed TU M ah" Date 19 Owner or Odner's Desdnee Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, hpiding a valid comminion issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province ofdyl*I and employed by M A d AI of her //c *./ 6 have inspected the components described in this Own'er's R'oport during the period

  • IMN f/A /*

to

. and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI, By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report, Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection, gggmlggggng MW/

1gJ d

Inspector's Stoneture Nationel Board, $tefe, Province, and Endorsements Date 87// Je 19 P(

r l

Dockst Number: 50-339 Serial Number: 96-629 Page 24 of 68 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 4

g, g, Virgine Electric & Power Company September 27,1996 Date Name 5000 Dominion Blvd., Glen Allen, VA 23060 1

1 gg, Addreas

2. Plant North Anna Power Station Unit 2

Name P.O. Box 402. Mineral, VA 23117 R/R 96 295 W.O. 347464-02 DCP 94102 Address Repair orpenization P.O. No., Job No., etc.

3. Work Performed by Virginia Electric & Power Company N/A Type Code Symbol Stamp Authorization No.

5000 Dominion Blvd., Glen Allen, VA 23060 N/A Expiration Date Address

4. Identification of System Recire. Spray 4
5. (a) Applicable Construction Code ANSI B31.7 9969 Edition,1970 Addenda, 78, 81, 83tR),11 Q g 4

(b) Applicable Edition of Section XI Utillred for Repairs or Replacements 19 86

6. Identification of Components Repaired or Replaced and Replacement Components 4

ASME j

Code National

Repaired, Stamped Name of Name of Manufacturer Board Other Year
Replaced, (Yes Component Manufacturer Serial No.

No, identification Bullt or Replacement or No)

Pipe Support.

N/A N/A N/A 2-RS-R-608 Unk.

Replacement No i

i i

7. Description of Work Modified existing support for 1/2" and 1" leakoff lines.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure psi Test Temp.
  • F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used provided (1) size is 8% in. x 11 in., (2) informe-tion in items 1 through 6 on this report i. Included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82)

This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 i

~_.

I l

FORM NIS 2 (Back)

9. Remarks ASME Class 2 Applicable Manufacturer's Date Reports to be attached Pcrformed ASME Section XI preservice VT 3 l

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this _ replacement conforms to the rules of the ASME Code, Section Xl.

'****P'***""'

N/A Type Code Symbol Stamp

^

Certificate of Authorization No.

Expiration Date Signed

/M T 'I NMC k

@vner o/ Owner's Designee, Title -

Date A

2.7 1g M CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holping a, valid commission issued by the National Board of Boiler and fressure Vessel inspectors and the State or Province of VMa'a>L and employed by # 8,8 M of N*/ AM

,have inspected the components described in this Owner's ileport during the period AIll"AT 8!N to_

and state that to the best of my knowledge and belief, the Owner has performed examinati'sns and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Sr.tlon XI, By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection, 4

Commissions VA h e' 4W Inspector's signature National Board, Stati, Province, and Endorsements j

M JJ 19 T(

Date l

l i

1 l

DockOt Numbers 50-339 Serial Number: 96-629 Page 25 of 68 i

FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Vergmia Electric & Power Company September 24,1996 g, %,

]

Name 5000 Dominion Blvd., Glen Allen. VA 23060 Sheet of Addreas 2

2. Plant North Anna Power Station Unit Name P.O. Box 402, Mineral, VA 23117 R/R 96-316 W.O. 34117419 Address Hepair Oreenlaation P.O. No., Job No., etc.

L Work Performed by VirQinia Electric & Power Company N/A Type M SymW SW Nam

  • N/A

^"

'I#8*I " **

5000 Dominion Blvd., Glen Allen, VA 23060 nua Expiration Date

4. Identification of System Quench Spray
5. (a) Applicable Construction Code ANSI B31.7 69 Edition,1970 Addenda 8,81,83W, M b Caes gg (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 j

i

6. Identification of Components Repaired or Replaced and Replacement Components ASME

+

Com National

Repaired, Stamped Name of Name of Manufacturer Board Other Year
Replaced, (Yes Component Manufacturer Serial No.

N o.

Identification Built or Replacement or No)

]

Stud Structural.

Unknown Unknown N/A 2-OS-TE 2005 Unk.

Nep:aceo rio 1/2" Die, j

Nut, Unknown Unknown N/A 2-05 TE-2005 Unk.

Neplaceo no 1/2" Dia.

Stud Structual, Mackson, Inc.

Heat No.

N/A 2-GS-I L-2 00t3 Ivvo rieplacement rw 1/2" Dia.

60451

Nut, Mackson, Inc.

Heat No.

N/A 2-OS-TE-200B 1996 Replacement No 1/2" Dia.

97364

7. Description of Work Replace botting. programatic work
8. Tests Conducted: Hydrostatic 0 eneumatic 0 Nominal Operat:ng Pressure Other Pressure psl Test Temp.

'F NOTE: Supplemental sheets in form of lists, sketches, or drawings rney be used, provided (1) size is 8% in. x 11 in., (2) Informa.

tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82)

This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017

. -... ~..

- -. ~ _... -...

4

}'

FORM NIS 2 (Back)

9. Romerks ASME Class 2 4

Applicable Manufacturer's Data Reports to be attached 4

3 2

CERTIFICATE OF COMPLIANCE

}

We certify that the statements made in the report are correct and this reDleComent conforms to the rules of the ASME Code,Section XI.

'***3'***'***'"'"'

,1 i

Type Code Symbol Stamp N/A

)

Certificate of Authorization No.

N/A N/A Expiration Date I

EM 'd N Signed Date 19

@vner or 06vner's Designee, Title '

3 1

4 CERTIFICATE OF INSERVICE INSPECTION l, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State j

or Province of M/dd and employed by # J' 8 Idf of i

Are M la"

/ ?-

have inspected the components described in this Owner's Rohrt during the period M

N MMM to

. and state that j

to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any menner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Nn N ~

Comminions VA W W 2WA Inspector's Signature National Board, S' tete, Province, and Endorsements

~

i Dets '

Ju/ 24' 19 fl

)

I i

4 i

i

Dock 0t Numbers 50-339 Serial Number: 96-629 Page 26 of 68 FORM NIS 2 OWNER'S REPORT FOR REPAlR$ OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI i

Virginia Electric & Power Company September 25,1996 4

1. Owner Date Name 5000 Dominion Blvd., Glen A!!en, VA 23060 1

1 3

Addrene

2. Plant North Anna Power Stat 6on Unit Name P.O. Box 402, Menerat, VA 23117 R/R 96 321 W.O. 350604-01 Address Repair oreenization P.O. No., Job No., etc.
3. Work Performed by Vi'0'"'a Electric & Power CompanV N/A Type Code Symbol Stamp-Name mg 5000 Dominion Blvd., Glen Allen. VA 23060 Authorization No.

Addreas

4. Identification of System
6. (a) Applicable Construction Code ANSI 831.7 69 O

b Case gg

Edition, Addenda (b) Applicable Edition of Section XI Utilized for Repairs or Reptocements 19
6. Identification of Components Repaired or Replaced and Replacement Components l

ASME t

Code Netional

Repaired, Stamped i

Name of Name of Manufacturer Board Other Year

Replaced, (Yes Component Manufacturer Serial No.

No.

Identification Built or Replacement or No)

Stud Structural.

Unknown Unknown N/A 4-r16-riLv escou una.

nep;acco nu 7/8" Dia.

Stud Structual, Mackson, Inc.

Heat No.

N/A 4-ML-r1Lv-4DDov inuo napsse mm hv 7/8" Dia.

38287

7. Description of work Replaced body to bonnet studs boric acid on studs from a packing leak.
8. Tests Conducted: Hydrostatic Pneumatle O Nominal Operating Pressure Other] Pressure psi Test Temp.

'F NOTE: Supplemental sheets in form of lists, sketches, or drowings mey be used, provided (1) size is 8% in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

)

(12/82)

This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017

)

l I

1 FORM NIS 2 (Back)

)

9. Remarks ASME Class 1 Applicable Manufacturer's Date Reports to be etteched i

CERTIFICATE OF COMPLIANCE We certify that the stetements made in the report are correct and this re n ta rement conforms to the rules of the ASME Code, Section Xl.

A*'P"*"'

Type Code Symbol Stamp N/A Certificate of Authortration No, N/A N/A Expiration Date Signed O

TC 8"4 d**r Date I* '

W 2S 19 N

/

Owner or Oder's Designe( Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, hol, ding a valid commission issued by the National Board of Bo!!ar and Pressure Vessel Inspectors and the State or Province of V"ee *e 5 and employed by # I #' I#1 of McM/uM. (f have inspected the components described in this Owner's Report during the period

  • M 9 * !N to

. and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI, By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any perso,1al injury or property damage or a loss of any kind arising from or connected with this inspection.

N 8/

Commissions W WY I#A inapoctor's Signature National Board, Stefe, frovince, and E ndorsements 5fl W 19 N Date f

l l

Dock t Numbers 50-339 Serial Number: 96-629 Page 27 of 68 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Virginia Electne & Power Company September 23,1996 Name 5000 Dominion Blvd., Glen Allen, VA 23060 Sheet of Addreen

2. Plant North Anna Power Station Unit 2

Name

]

P.O. Box 402, Mineral, VA 23117 R/R 96-330 W.O. 34117418 Address Repair Organization P.O. No., Job No., etc.

3. Work Performed by Virgini2 Electric & Power Company N/A Type Code SymW Sep Name N/A Authoriretion No.

5000 Dominion Blvd.4 Glen Allen, VA 23060 Mmh h

4. Identification of System Quench Spray i
6. (a) Applicable Construction Code ANSI B31.7 69 Edition,1970 Addende 8, 81, 8M,1 be Case gg (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19
6. Identification of Components Repaired or Replaced and Replacement Components ASME Code j

fu.unal

Repaired, Stamped Name of Name of Manufacturer Board Other Year
Replaced, (Yes Component Manufacturer Serial No.

No.

Identification Built or Replacement or No)

Stud. Structural Unknown Unknown N/A 4-us it evva un a,

r eplacco hv 1/2" Dia.

Nut, Heavy Hex Unknown Unk nown N/A 4 ud-i t-evva

una, nesieveu iev 1/2 Dia.

~5tud, structural Mackson, inc.

Neat no, n/a e-us-i t 2vva ih56 n= view m-m i4v 1/2" Dia.

60451 Nut, Heavy Hex Mackson, Inc.

Heat No.

N/A 2-Gs-I t;-Z UVA 1vv0 Heplacement no 1/2" Dia.

97364

7. Description of Work Replace botting due to corrosion
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure O Other O Pressure psl Test Temp.

'F NOTE: Supplemental sheets in form of lists, sketches, or drawings rney be used, provided (1) size is 8% in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each shee' t, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82)

This Form (E00030) may be obtair'ed from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017

FORM NIS-2 (Back)

9. Remarks ASME Class 2 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the ru'a of the ASME Code, Section Xl.

'***I'*P'***'"*"'

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A

^

Expiration Date Signed Date 19 b Ower or Owner's Des 6snee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Prnvince of SNerE and employed by ##A EI of M eMc-have inspected the components described in this Owner's Rs' ort during the period F H/M F/MAI p

to

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI,

.By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor h;s employer shall be llable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Wu/ 8 Commissions VWJ/

IN4 Inspictor's signature National Board,5t' ate,~ Province, and Endorsements Date Ae/ 2/ 19 Il r

Dockst Number 50-339 Serial Number: 96-629 Page 28 of 68 r

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner V'rgania Electric & Power Company Date October 4.1996 Name 5000 Dominion Blvd., Glen Allen. VA 23060 Sheet 1

of 1

Address

2. Plant Ncrth Anna Power Station Unit 2

Name je Q P.O. Box 402, Mineral. VA 23117 R/R 96-331 W.O. 3505199f 4 b

Addreas Receir Oreenfistion P.O. No., Job No., etc.

3. Work Performed by Virainia Electric & Power comoany Type Code Symbol Stamp N!A Authorization No.

N/A cnnn nntnininn niva ni.n Ait.n VA 7inan Expiration Date mA Address

4. Identification of System Feedwater
5. (a) Applicable Construction Code NA41MR 19 71 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacem6nts 19 86
6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National
Repaired, Stamped Name of Name of Manufacturer Board Other Year
Replaced, (Yes I

Component Manufacturer Serial No.

No.

Identification Built or Replacement or No)

Check Valve Crane CV07002 N/A 2-FW-62 1971 Repaired No 0.1.3 l

7. Description of Work n.mm, a o.u.. em,..m..

.ma..in...n.a

8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure 13 o psi Test Temp. 3M r

NOTE: Supplemental sheets in form of lists, sketches, or drawings rney be used, provided (1) size is 8% in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82)

This Form (E00030) may be obtained f rom the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017

m..

.. __. _.m

_..____..____.__m

~

l l

)

i i

FORM NIS 2 (Back)

9. Remarks -

ASME Class 2 Applicable Manufacturer's Date Reports to be attached Performed construction code MT and RT examination after installation.

l I

Performed ASME Section XI preservice MT and UT exainination.

i Code Case N41641 was invoked.

Performed in-process repairs of weld 14B, pipe-to-valve weld, under this program.

1 4

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this reosir conforms to the rules of the ASME Code,Section XI.

j Type Code Symbol Stamp N/A 1

Certificate of uthorization NoS N/A Expiration Date Signed I5I '

WI 1

Date 8 d 19 Owner or Owner's Desiones, Title

/

CERTIFICATE OF INSERVICE INSPECTION

)

j I, the undersigned, h,olding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of /WES and employed by #J8M of

  1. w A/w*/ Lh have inspected the components described in this Owner's Report during the period MfbA

/*NVbl to

. and state that to the best of my knowledge and belief, the Owner has perforrned examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing"this certificate neither the inspector not his employer makes any warranty, expressed or implied, concerning the l

examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer i

shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this I

l Inspection, d

8 Commissions WW E#A Insoector's signature National Board [St(te, Province, and Endorsements Date MV I 19 f8

~,

i i

Dock 0,t Numbers 50-339 Serial Number: 96-629 Page 29 of 68 FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Wrginia Electric & Power Company September 20.1996 Name 5000 Dominion Blvd., Glen Allen. VA 23060 sheet of Address i

2. Plant North Anna Power Station 2

Unit Name P.O. Box 402, Mmeral, VA 23117, R/R 96-336 W.O. 350956-01 Address Repelr Orgenlaation P.O. No., Job No., etc.

3. Mrk Performed W Virginia Electric & Power Company N/A Type Ce SW SW j

^"

na 5000 Dominion Blvd., Glen Allen, VA 230 0 Expiration Date Address

4. Identification of System
5. (a) Applicable Construction Code ANSI B31.7 69 Edition,19 0 Addenda, 8,81,83(R),11Q Case 39 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19
6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National
Repaired, Stamped Name of Name of Manufacturer Board Other Year
Replaced, (Yes Component Manufacturer Serial No.

No, identification Built or Replacement of No)

Pipe 3/4" NPS Grinnel None NA 2-RC-203 Unk.

Repaired No l

7. Description of Work Repaired 3/4" indication found during augmented liquid penetrant exam.
8. Tests Conducted: Hydrostatic 0 Pneumatic Nominal Operating Pressure OtherO Pressure psi Test Temp.

'F NOTE: Supplemental sheets in form of lists, sketches, or drawings rney be used, provided (1) size is 8% in. x 11 in., (2) informa.

tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82)

This Form (E00030) may be obtained f rom the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017

FORM NIS 2 (Back)

9. Remarks ASME Class 1 Applicable Manufacturer's Date Reports to be etteched i

l CERTIFICATE OF COMPLIANCE We certify thet the statements made in the report are correct and this mpair conforms to the rules of the ASME Code, Section X1.

Type Code Symbol Stamp. N/A N/A Expiration Date "##

Certificate of Authorization No.

Signed -

1 M

IN b"#"

Date 19 Qwner orgwner's DEsignes, Title LERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State 1

or Province ofj d2 and employed by # In E 2 #1 of Mo+/IM fI have inspected the components described in this Owker's Report during the period 9IF FI d

I to and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI, By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions W YJ Y ANE Insoector's Signature Nationet soord, stati, Province, and Endorsements Date SuY 21 19 98 r

s

..-, ~ _ _ - ~

DockGt Numbers 50-339 Serial Number: 96-629 Page 30 of 68 FORM Nis-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Virginia Electnc & Power Company September 25,1996 Nome 5000 Dominion Blvd., Glen Allen, VA 23060 1

1 3

M Address

2. Plant North Anna Power Station 2

Unit Name P.O. Box 402, Mineral, VA 23117 R/R 96-337 W.O' 341174-13 Address Repair Orsenization P.O. No., Job No., etc.

}

3. Work Performed by Virginia Electne & Power Company.

N/A Type Code Symbol Stamp Name N#^

Authorization No.

5000 Dominion Blvd., Glen Allen, VA 23060 Expiration Date Adow Quench Spray

4. Identification of System S. (a) Applicable Construction Code ANSI B31.7 69 gg Edition,WO Addenda b Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19
6. Identification of Oomponents Repaired or Replaced and Replacement Components ASME Code National
Repaired, Stamped Name of Name of Manufacturer Board Other Year
Replaced, (Yes Component Manufacturer Serial No.

No.

Identification Built or Replacement or No)

Cap Screw, Unknown Unknown N/A 2-ud-4.;

Ur' K.

nepl3Ceu 14 0 3/8" Dia.

Nut, Unknown Unknown N/A 2-Ub-4J UnK.

neplacog no 3/8' Dia.

~Ca~p Screw, Aihed Nut & Bolt Heat No.

N/A 4 -ud-9 J 1550 riepia vsment nu 3/8" Dia.

36746

Nut, Mack son, Inc.

Heat No.

N/A 2-05-43 1932 Replacement No 3/8" Dia.

31742

7. Description of Work Replace body to bonnet botting - programatic work
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure psi Test Temp.

'F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) informe-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82)

This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017

..m.

_ _. _ _ _.... _. _ _ _ _ _ _ _ -..... -... _. _. ~..

_...__..__.__s FORM NIS 2 (Beck)

9. Remuks ASME Ckss 2 Applicable Manufacturer's Data Reports to be attac l

1 l

1 CERTIFICAYE OF COMPLIANCE We certify that the statements made in the report are correct and this foolacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A N/A Expiration Date Signed M

Tie 7 64Ah Ownerpr Owner's Designee, Title Date 8

2#

1996

'1 CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province ofd*% Aa/r and employed by MlMAZ of

  1. NA/
  1. F have inspected the components described in this Owners Rohrt during the period M/MN F! d'

/7 and state that to to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described 1n this Owner's Report in accordance with the requirements of the ASME Code Section XI.

By signing this certificate neither the inspector nor his employer makes any warrenty, expressed or imphed, concerning the examinations and corrective rnessures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any menner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection, d

8 Commissions VA W V 2#>

Inspector's Signature National Board, State, Pfavince, and Endorsements Date Je/Y 21' 19 N

l

)

Dock;t Number: 50-339 Serial Number: 96-629 1

i Page 31 of 68 FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1, hr Virginia Electric & Power Company September 25,1996 Name 5000 Dominion Blvd., Glen Allen, VA 23060 Sheet of Address

2. Plant North Anna Power Station Unit 2

Nome P.O. Box 402, Mineral. VA 23117 R/R 96 339 W.O. 34117412 Address Repair Oreanization P.O. No., Job No., etc,

3. Work Performed by Virginia Electric & Power Company N/A Type Code Sym Step

^"*

Na 5000 Dominion Blvd., Glen Allen, VA 230 0 Expiretion Date Address

4. Identification of System Quench Spray
5. (a) Applicable Construction Code ANSI B31.7 gg 69 Edition,1970

.-- Addende, 8, 81, 83W,11 Q Case 86 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19

6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National
Repaired, Stamped Name of Name of Manufacturer Bosrd Other Year
Replaced, (Yes Component Manufacturer Serial No.

N r.,

identification Built or Replacement or No)

Cap Screw, Unknown Unknown N/A 2-05-68 Unk.

Replaced NO

^3/8" Dia.

Cap Screw, Unknown Unknown N/A 2 05-65 Unk.

Heplaceo No 3/8" Dia.

Cap Screw, Allied Nut &

Heat No.

N/A 2-05 'JU lWUZ Heplacement No 3 /8 ". Dia.

Bolt 36746 i

Cap Screw, A & G Eng.

Heat No.

N/A 2 05-68 1989 Replacement No 3/8" Dia.

9M977

7. Description of Work Replace body to bonnet botting - programatic work
8. Tests Conducted: Hydrostatic 0 Pneumatic Nominal Operating Pressure Other Pressure psi Test Temp.

'F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on sech sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82)

This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017

1 l

FORM NIS-2 (Back)

9. Remarks ASME Class 2 Applicable Manufacturer's Data Reports to be atteched 1

l CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this reolacement conforms to the rules of the ASME Code,Section XI,

*3''***"'*"*

l Type Code Symbol Stamp N/A l

Certificate of Authorization No, N/A N/A Expiration Date Signed Date SMm 2f to M Owner # Owner's Designee, Title i

CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holging a valid coamission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of Y'r*>EsA and employed by M J e ###

of

  1. < r/./o * / Ch h

in ted the components described in this Owner's Report during the period MNI to I

and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection, N

Commissions VMV INJ 6

Inspector's Signature National Board, S'teti, Province, and E ndorsements Date J

d 19 h

Dockst Numbers 50-339 Serial Number: 96-629 Page 32 of 68 FORM Nis-2 OWNER'S REPORT FOR REPAlRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Virginia Electric & Power Company October 3,1996 Name 6000 Dominion Blvd., Glen Allen, VA 23060 1

1 Sheet of Addreas

2. Plant North Anna Power Station Unit Name P.O. Box 402, Mineral, VA 23117 R/R 96-352 W.O. 351036 01 Address Repair Orsenization P.O. No., Job No., etc.
3. Work Performed by Virginia Electric & Power Company N/A Type Code Symbol Stamp g,,,

5000 Dominion Blvd., Glen Allen, VA 23060 Authorization No.

~

Expiretion Dete_

Address E#

4. Identification of System
6. (a) Applicable Construction Code ANSI B31.7 69 O

39

Edition, Addenda; Code Cass (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19
6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National
Repaired, Stamped Name of Name of Manufacturer Board Other Year
Replaced, (Yes Component Manufacturer Serial No.

No.

Identification Built or Replacement or No)

Stud S:ructural, unknown unknown n/A e-us a s Un n.

Aspiavad Nv 1/2" Dia.

Nut, Unknown unknown nia 4-us-as
Unn, n=p;auwd Nw 1/2" Dia.

Etud structuai.

Mackson,inc.

neat no, nia 4 05-H ieoo n v;-w-m.m N.

1/2" Dia.

60451

Nut, Mackson, Inc.

Heat No.

N/A FU:>-J I 1Uu0 neplacement oso 1/2" Dia.

97364

7. Description of Work Replaced bolting during repair of valve seat for leakby.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure OtherO Pressure pel Test Temp.

'F NOTE: Supplemental sheets in form of lists, sketches, or drowings may be used, provided (1) size is 8% in, x 11 in., (2) Informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82)

This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017

=

~..

-. ~ _

l l

l l

1 l

I l

i FORM NIS-2 (Back) f

9. Remarks ASME Class 2 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this reDlecement Conforms to the rules of the ASME Code,Section XI.

'*"*D'***'"*"'

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A N/A Expiration Date Signed fAben

%$Z LA Mer Date 0c I

19 N Owner or 0%ner's Dedienee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of d,N,E and employed by

  1. f 81/J of de/A-U have inspected the components described in this Own'er's Report during the period M8Ns FMR to

. and stets that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

M Commissions VA W F M4 inspector's Signature National Board, State, Province, and Endorsements Date Os N f 19 N

~

DockOt Numbers 50-339 Serial Number: 96-629 Page 33 of 68 l

FORM Nis.2 OWNER'S REPORT FOR REPAIRS OR REPt.ACEMENTS As Required by the Provisions of the ASME Code Section XI

1. OwnerY,roNw bbdric k kewer [.

o,mu pote

/ o,2 R. 9 L J

Name 1

J fccoheWwisabV. be a b (H VA 1sexo Sheet 1

1 o,

/ Addrous

2. Plant Nu d we beJt f bhb e4 Unit 1

Name i

P.O. P> e x 4o1. Mire <x. l/A 1 sin e/a 9(-H3 %.o. t s l o n-o l

/

Aderses

'~

Moosir ordenlaation P.O. No., Job No., etc.

3. Work Performed byb r<iwL Type Code Symbol Stamp d!

e rio de f b~w d

I Authorization No.

M sce r_ bM ni ew bud. k w Ah<

VA s.s et o Espir. tion oeie

  1. /A

/ Address

/

bVt%e b

4. Identification of System DfAu l

J

5. (a) Applicable Construction Code N3l bil.9 19dEdition, M0 Addende,M W # 6 Code Coos (b) Applicable Edition of Section XI Utill ed for Repairs or Replacements 19 N(

l

6. Identification of Components Repaired or Replaced and Replacement Components I

ASME Code National

Repaired, Stamped Name of Name of Manufacturer Board Other Year
Replaced, (Yes Component Manufacturer Serial No.

No.

Identification Built or Replacement or No)

)

SWA3

%M

%D d/A 2-Qs-Yo IWI P4pL.J No

&b h3 BJt 8'(dij d/4 2-Q.s -4o ms $~~t No 3

7 Description of Work keO bwi.

M L.

Va e_

oe I

J

8. Tests Conducted: Hydrostatic Pneumatic 0 Nominal Operating Pressure O Other Pressure psi Test Temp.

'F NOTE: Supplemental sheets in form of lists, sketches, or drowings may be used, provided (1) size is 8% in. x 11 in., (2) Informe.

tion in items 1 through 6 on this report is included on each sheet, and (3) wh sheet is numbered and the number of sheets is recorded et the top of this form.

(12/82)

This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 REPRINT 12/91

l j

i i

FORM NIS 2 (Seck)

9. Romerks 9S 1 appmat,i. uenutectu,.re om peoo,,s to t,e ette.e.

\\

~

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report ere correct and this r at m h conforms to the rules of the ASME Code,Section XI.

U''***'"*"'

Type Code Symbol Stamp

/

Certificate of Authorize 'on No Empiretion Date e

/

, f b

n1 I 1b 9b Signed W

IbI iW /

Date 19 Owner or Owners Deseessee, Title j

CERTIFICATE OF INSERVICE INSPECTION t, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Provmce of / Ed end employed by # # 8 I 'I of 1

A'e r//' e*/

67 h

inspected the components described in this Owner's Report during the period IIMN MN to

. end state that to the best of my knowledge end belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinettons and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liebre in any menner for any personel injury or property damage or a loss of any kind arising from or connected with this inspection.

N-f/h to

. and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

M M.

Cornmissions VA &

MA Inspector's Signature National Board, State,' Province, and Endorsements Date Os N /

19 El

1 Dockst Numbers 50-339 Serial Number: 96-629 Page 37 of 68 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

%rginia Electric & Power Company October 1,1996 j

Name 5000 Dominion Blvd., Glen Allen, VA 23060 1

1 3

Addreas

~

2. Plant North Anna Power Station Unit 2

Name P.O. Box 402, Mineral, VA 23117 R/R 96-360 W.O. 350962-01 Address Repelt Orgenlaation P.O. No., Job No., etc.

3. Work Performed by Virginia Electric & Power Company N/A Type Code Symbol Stamp Authorization No.

5000 Dominion Blvd., Glen Allen, VA 23060 rCA Expiration Date Address

4. Identification of System Component Coohng
5. (a) Applicable Construction Code ANSI B31.7 69 Edition,1970 Addenda, 78, 81, 8M,11 b Case gg 86 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 1
6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National Repaired.

Stamped

{

Name of Name of Manufacturer Board Other Year

Replaced, (Yes Component Manufacturer Serial No.

No.

Identification Built or Replacement or No) l Stud Structural, Unknown Unknown N/A 2-CC 302 Unk.

Replaced No 3/4" Dia.

Nut, Unknown Unknown N/A 2-CC-302 Unk.

Replaced No 3/4" Dia.

l Stud Structual, Mackson, Inc.

Heat No.

N/A 2-CG-302 1UUb Heplacement No 3/4" Dia.

M51482

Nut, Mackson, Inc.

Heat No.

N/A 2-CC-302 1996 Replacement No 3/4" Dia.

16409)I 7, Description of Work Replace bolting during repair for failed Type C test.

8. Tests Conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure Other Pressure psi Test Temp.

'F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) informe.

tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82)

This Form (E00030) may be obtained from the Order Oept., ASME,345 E. 47th St., New York, N.Y.10017

l l

I l

FORM NIS 2 (Back)

9. Remarks ASME Class 2 Applicable Manufacturer's Oate Reports to be attached r

1 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and thit. replacement con 8orms to the rules of the ASME Code,Section XI.

'*P'"'*****"*

Type Code Symbol Stamp N/A N/A Certificate of Authorization No.

Expiration Date " ^

Signed

$AlfL"

  • 3 3% B'4 ***2 Date Owner or CWuner's D(signee Title A Oe! E I

19 CERTIFICATE OF INSERVICE INSPECTION i, the undersigned, holding a valid comminion issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of SN=2 and employed by M' J 8 l#I of der M e# I have inspected the components described in this Own'er's Report during the period N/6/N N/NN to

. and state that to the best of my knowledge and belief, the Owner has performed examinations and teken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

b Commissions N 92 V 2M/

snapactofs signature National Board, State, Province, and E ndorsements Date 80

/

19 N

DockOt Numbers 50-339 h.

Serial Number: 96-629 Page 38 of 68 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS i

As Required by the Provisions of the ASME Code Section XI Virginia Electric & Power Company October 1,1996 N.me 5000 Dominion Blvd., Glen Allen. VA 23060 1

I SW of Address

2. Plant North Anna Power Station 2

Unit Name P.O. Box 402, Mineral, VA 23117 R/R 96 361 W.O. 35096341 Address Rooelr Organization P.O. No., Job No., etc.

3. Work Performed by Virginia Electric & Power Company N/A Type Coe Symbol Step Name N/A Authorization No.

5000 Dominion Blvd., Glen Allen, VA 23060 Empiration Date j

Ad dress

4. Identification of System Cornponent CooGng
5. (a) Applicable Construction Code ANSI B31.7 69_ Edition,1970 Addenda 78,81,83W, H Q Caos gg 86 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 a
6. Identification of Components Repaired or Replaced and Replacement Components ASME Code j

National

Repaired, Stamped Name of Name of Mcnufacturer Board Other Year
Replaced, (Yes Component Manufacturer Serial No.

No.

Identification Built or Replacement or No) i Stud Structural.

Unknown Unknown N/A 2-GG ZUS Unk.

Heplaceo No i

3/4" Dia.

1 e

Nut, Unknown Unknown N/A 2 GG-ZUU Unk.

Heplaceo no 1

3/4" Dia, 1

Stud Structual, Mackson, Inc.

Heat No.

N/A 2 GG-45U luvo rteplacement sig 3/4" Dia.

A151482 Nut.

Mackson, Inc.

Heat No.

N/A 2-CC-2 89 1996 Replacement No s

3/4" Dia.

16409JI 4

7. Description of Work Replace botting dunng repair for failed Type C test.
8. Tests Conducted: Hydrostatic 0 Pneumatic Nominal Operating Pressure Other O Pressure psi Test Temp.

'F i*

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) Informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82)

This Form (E00030) may be obtained from the Order Dept., ASME,345 E 47th St., New York, N.Y.10017

- -.. _.. - ~. - -

~... ~ - _. _ ~. _.. _ ~ ~.. _ _ -

1 i

l l

l l

i FORM NIS 2 (Back)

9. Remarks ASME Class 2 Applicable Manufacturer's Date Reports to be etteched CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement confoims to the rules of the ASME Code, Section Xl.

'**P'***"'*"'

N/A Type Code Symbol Stamp N/A N/A Certificate of Authorization No, Expiration Date 1

A '"

752 O=tmeer-Date och I

_Ig f4 Signed a

=

Owner orCwner's'beeignee Title

\\

CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a, valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State I

or Province of Y/N"#

  • and employed by M J 8 I#I-of Mu//es *2 &

have inspected the components described I

in this Owker's Report during the period M6M 9/27/95 to

, and state that 4

to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this f

Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer r"nakes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

h N

~

Commluions VA Y2 V PMJ inspector's Signature National Board, Stat ( Province, and Endorsements Date N /

19 N i

i

Dockit Numbers 50-339 Serial Number: 96-629 Page 39 of 68 FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Proeisions of the ASME Code Section XI Virginia Electric & Power Company October 1,1996 Nome 5000 Dominion Blvd., Glen Allen, VA 23060 Sheet of Addreas

2. Plant North Anna Power Station 2

Unit Nome P.O. Box 402, Mineral, VA 23117 R/R 96 362 W.O. 350961-01 Address Repelt Oreentration P.O. No., Job No., etc.

3. Work Performed by Virginia Electric & Power Company N/A Type Code Symbol Stamp 5000 Dominion Blvd., Glen Allen, VA 23060 Authorization No.

Address

'"E

"*"I

""U

4. Identification of System
5. (e) Applicable Construction CodeANSI B31.7 69 39 Edition,1 Addende.

Code Case 0

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19

6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National
Repaired, Stamped Name of Name of Manufacturer Board Other Year
Replaced, (Yes Component Manufacturer Serial No.

No.

Identification Built or Replacement or No)

Stud Structural, Unknown Unknown N/A Z-LL-4/o unA.

Psapacaa rm 3/4" Dia.

Nut, Unknown Unknown N/A 2-LL-4 / D UnK.

rteplaceu ng 3/4" Dia.

Stud Structual, Mackson, Inc.

Heat NO.

N/A 4-LL-4/o lupo neplacumum no 3/4* Dia.

M51482

Nut, Mackson, Inc.

Heat No.

N/A 2-CG-276 1UUU Meplacement NO 3/4" Dia.

16409JI

7. Description of Work Replace botting during repair for failed Type C test.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure OtherO Pressure psi Test Temp.

'F NOTE: Supplemental sheets in form of lists, sketches, or drawings rney be used, provided (1) size is 8% in. x 11 in., (2) Inforrne.

tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

l t

(12/82)

This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 i

t l

~

I 1

FORM NIS 2 (Back) i

9. Remarks ASME Class 2 Applicable Manufacturer's Data Reports to be attached s

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacernent conforms to the rules of tne ASME Code,Section XI,

'*A'***"'*"*

N/A Type Code Symbol Stamp N/A N/A Certificate of Authorization No.

Exp.iration Date Signed 2 C E'AM Date O I

19N Owner # owner'stesignee, Title V

CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid comminion issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of M"N and employed by

  1. ' / 8 hf of O/AM bf have inspected the components described in this Owner's Report during the period NdN(

HAE to

. and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning k

examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his empic, Air shall be liable in any manner for any personal injury or property damage or a foss of any kind arising from or connected with this inspection.

k 4

Commissions V4 W V 2#4 Inspector's signature National Soard,'Sta'te, Province, and Endorsements Date 8c / /

19 J's

DockOt Numbers 50-339 Serial Number: 96-629 Page 40 of 68 FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS l

As Required by the Provisions of the ASME Code Section XI

1. Owner Virginia Electric & Power Company Date October 4,1996 Nome 5000 Dominion Blvd., Gien Allen, VA 23060 Sheet i

of 1

Addreen

2. Plant North Anna Power Station 2

Unit Name P.O. Box 402, Mineral, VA 23117 R/R 96-363 W.O. 350524-01 Address Repair Organization P.O. No., Job No., etc.

3. Work Performed by Crane Valves Nuclear Operations Type Code Symbol Stamp N/A Authorization No.

N/A RSO Reminntinn Blvd Bolinnbronk. tL 60440 Expiration Date N/A 4

Address t

4. Identification of System Feedwater 4
5. (a) Applicable Construction Code NAS-163B 19 71 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 86 i
6. Identification of Components Repaired or Replaced and Replacement Components ASME l

Code National

Repaired, Ftamped i

Name of Name of Manufacturer Board Other Year

Raniaced, (Yes i

Component Manufacturer Serial No.

No.

Identification Built or Replacement or No) j Check Valve Crane CV07002 2 N/A 2-FW-94 1971 Repaired No 0.1.2 3

4 e

9

7. Description of Work norsn.a n.a., en,# r. n n97 en annw f nr nrnn., n ting of dme
8. Tests Conducted: Hydrostatic Pneumatic 0 Nominal Operating Pressure Other O Pressure psi Test Temp.

'F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) Informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is eumbered and the number of sheets is i

recorded at the top of this form.

i (12/82)

This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017

=.

...___.___..m.

. ~.... _.. _ _ -. _ _ _ _.. _ _.. _.__

4 4

f t

1 3

i, 4

4 i

FORM NIS-2 (Back)

9. Remarks AWE Ns 2 Applicebte Menutecturer's Data Reports to be attached l

- Performed construction code LP examination after machining.

I I

i I

2 CERTIFICATE OF COMPLIANCE j

We certify that the statements made in the report are correct and this repak conforms to the rules of the ASME Code,Section XI.

repair or replacement 4

l N/A Type Code Symbol Stamp 3

N/A N/A Certificate of Authorization No.

Empiration Date AY TSZ GM k!**

'}

Owner or Owner's treelenee. Title Date DC U

V' 19 Yd Sened 3

]j CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of V#u"N and employed by

  1. I 8 T'f of ide//o.-d <f have in ted the components described j.

in this Owners Re' port during the period M/a///

'to PIS

(

and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this l

Owner's Report in accordance with the requirements of the ASME Code,Section XI.

3 j

By signing this certificate neitt.or the inspector not his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer f

shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

{

inspection.

N6I N Commissions YM UF

  1. N/

Inspector's Sienature National Board, St'ete,' Province, and E ndorsements Date M8 v 9 19 #4 i

i

,m,

Dockst Numbers 50-339 Serial Number: 96-629 i

Page 41 of 68 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Virginia Electric & Power Company Date October 4.1996 Nome i

5000 Dominion Blvd., Glen Allen, VA 23060 Sheet 1

of 1

Addrome

2. Plant North Anna Power Station 2

Unit Name g

P.O. Box 402, Mineral, VA 23117 R/R 96 364.W.O. 350524 01 Address Repair Organiistion P.O. No., Job No., etc.

3. Work Performed by Viroinia Electric & Power Company Type Code Symbol Stamp N/A Authorization No.

N/A Moon nomininn Blvd-Glan Allan VA 230so Expiration Date N/A Address

4. Identification of System Feed water l
5. (a) Applicable Construction Code NAS-183B 19 71 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 86 l
6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National
Repaired, Stamped Name of Name of Manufactu er Board Other Year
Replaced, (Yes Component Manufer +urer Serial No.

No.

Identification Built or Replac9 ment or No)

Check Valve Crane CV07002 2-N/A 2-FW-94 1971 riepaired No 0.1.2

7. Description of Work narnnu.a v iv, en, r.n ;r ana r.;ne.li.a B. Tests Conducted: Hydrostatic 0 Pneumatic Nominal Operating Pressure Other @ Pressure MD psi Test Temp.

3)b

'F NOTE: Supplemental sheets in form of lists, sketches, of drawings may be used, provided (1) size is 8% in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82)

This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017

__m.

FORM NIS-2 (Back) i ASW Class 2

9. Remarks Applicable Manufacturer's Data Reports to be etteched Performed construction code MT and FIT examination after installation.

Performed ASME Section XI preservice MT and UT examination.

Code Case N-4161 was invoked.

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair conforms to the rules of the ASME Code,Section XI.

repair or repiecement a

N/A Type Code Symbol Stamp

"^

^

Certificate of Authorizat' n No-Expiration Date i

Signed Isr Em mete Makv-II i9 M 6 oate Owner or Owner's Desighes, Title d

CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of V'N Sr E-and employed by U M Ed of Mr/1 -

C f" have inspectop#&

the components described in this Owner's'Repob during the period FMIN f

' 0N Y/

to and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

~

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

M.

Commissions W Y2 Y ZNA a

inspector's signature National Board, State Province, and Endorsements Date M*'

V 19 N

Dock"t Numbers 50-339 Serial Number: 96-629 Page 42 of 68 FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. % ner Virginia Electric & Power Company October 4,1996 Date Name 5000 Dominion Blvd., Glen Allen VA 23060 Sheet I

of 1

Address North Anna Power Station

2. Plant Unit Name gg P.O. Box 402, Mineral, VA 23117 R/R 96-365,W.O. 350824-01 Address Repelr Orgenlietion P.O. No., Job No., etc.
3. Work Performed byVirginia Electric & Power Company Type Code Symbol Stamp N/A Authorization No.

N/A 5000 Dominion Blvd., Glen Allen, VA 23060 Expiration Date N/A Address

4. Identification of System Feedwater
5. (a) Applicable Construction Code NAS-1638 19 71 Edition, N/A Addenda, N/A Code Case j

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 86

6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National
Repaired, Stamped Name of Name of Menufacturer Board Other Year
Replaced, (Yes Component Manufacturer Serial No.

N o, Identification Built or Replacement or No)

Check Valve Crane CV11009 N/A 2-FW-126 1971 Repaired No 0.1.1

7. Description of Work Removed va!ve for reesir and reinstalled
8. Tests Conducted; Hydrostatic Pneumatic 0 Nominal Operating Pressure O Other ressure 90O psi Test Temp. 3K
  • p NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) Informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

i I

(12/82)

This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017

_ _ __~,

1 i

i 1

1 l

FORM NIS 2 (Back)

9. Remarks ASME Class 2 Applicable Manufacturer's Data Reports to be attached Performed construction code MT and RT examination after installation.

Performed ASME Section XI preservice MT and UT examination.

Code Case N-4161 was invoked.

l 1

l CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this recair conforms to the rules of the ASME Code,Section XI.

D*I''*****"'

)

Type Code Symbol Stamp N/A l

N/A N/A Certificate of Authoriration No, j Expiration Date Signed I5I Date 19 Owner or Owner's Designee,dTitle V

CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, hold,ing a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of b *f and employed by # # B WI of Ar <d/s. / 6 have i spected the components described in this Owner's beport during the period MN 9 I '

and state that to to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI, By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations ared corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

4d N Commissions V4 W V L M4 Inspector's Sipneture National Board, State, Province, and Endorsements Date M4 J' [

19 26

Dockst Number: 50-339 Serial Number: 96-629 Page 43 of 68 FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Viroitua Electric & Power Company Date October 4,1996 Name 5000 Dominion Blvd.., Glen Allen, VA 23060 Sheet I

of 1

Address

2. Plant North Anna Power Station 2

Unit 1

Name P.O. Box 402, Mineral, VA 23117 R/R 96-370 W.0,350824-01 Address Repair Oreenisetion P.O. No., Job No., etc.

3. Work Performed by Crane Valves Nuclear Operations Type Code Symbol Stamp N/A Narne Authorization No.

N/A RGO Rarninntinn Blvd.. Bolinabrook. tt 60440 Expiration Date N/A Address

4. Identification of System Feedwater
5. (a) Applicable Construction Code NAS-1638 19 71 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 86 l
6. Identification of Components Repelred or Replaced and Replacement Components ASME Code National
Repaired, Stamped

[

Name of Name of Manufacturer Board Other Year

Replaced, (Yes Component Manufacturer Serial No.

No.

Identification Built or Replacement or No) l Check Valve Crane CV110091 N/A 2-FW-126 1971 Repaired No l

0.1.1 1

I 1

7. Description of Work u.rs;n a n.

6., enrfar o n1r en miln for ornner samtic a of dine,

8. Tests Conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure O Other Pressure psi Test Temp.

'F l

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) Informs.

tion in items 1 through 6 on this report is included on sech sheet, and (3) each sheet is numbered and the number of sheets is

]

recorded at the top of this form.

i e

f (12/82)

This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 i

l

.m._

_ _ _ _ _,_ - - ~ ~ _ --

.m m._

J 4

FORM NIS-2 (Back)

ASME Class 2

9. Remarks Applicable Manufacturer's Date Reports to be attached Performed construction code LP examination after machining.

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code,Section XI.

''''*8'*****"*

  1. ^

Type Code Symbol Stamp

^

Certificate of Authorization No.

Expiration Dete Signed Lk TS2 N,'*

Date d k

19 U Ownfor Owner's Destense, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State i

or Province of VM /* S and employed by MJ# M of

/A-Me -#

f have inspected the components described in this Ownor's Report during the period FIIM PI b to

. and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.'

d By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions VJ W V EMA C

Inspector's signature Nationef Board, (tate, Province, and Endorsements Date Nc e'

/

19 N l.i s

f

..~ - - -, -, -

Dock t Numbers 50-339 Serial Number: 96-629 Page 44 of 68 FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Virginia Electric & Power Company Date September 30,1996 Nome 5000 Dominion Blvd., Glen Allen, VA 23060 Sheet 1

of 1

Addreas

2. Plant Nnrth Anna Power Station Unit 2

Name l

P.O. Box 402. Mineral. VA 23117 R/R 96-372 W.O. 351217-02 Address Repair oreenlastion P.O. No., Job No., etc.

3. Work Performed by Viroinia Electric & Power Company Type Code Symbol Stamp N/A j

Name A

Authorization No.

N/A 5000 Dominion Blvd.. Glen Allen. VA 23060 Expiration Date Addraes

4. Identification of System Safety injection
5. (a) Applicable Construction Code ANSI B31.7 1969 Edition 1970 Addenda. 78, 81. 83(RL 115 ode Case C

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1986

6. Identification of Components Repaired or Replaced and Replacement Components ASME Code i

National Repaired.

Stemped Name of Name of Manufacturer Board Other Year

Replaced, (Yes 4

Component Manufseturer Serial No.

No.

Identification Built or Replacement or No) d

Nut, Unknown Unknown N/A 2 SI-MOV-2867D Unk.

Heplaced No 3/4" Dia.

Nut, Mackson. Inc.

Heat No.

N/A 2-SI-MOV 2867D 1996 Replacement No 3/4" Dia.

16409JI

)

7. Description of Work Reclaced nuts - body to bonnet leak.
8. Tests Conducted: Hydrostatic 0 Pneumatic Nominal Operating Pressure Other Pressure psi Test Temp.

'F NOTE: Supplemental sheets in form of lists, sketches, or drawings rney be used, provided (1) size is 8% in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) sech sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82)

This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017

FORM NIS 2 (Back)

9. Remarks ASME Class 2

% sticable Manufacturer's Data Reports to be attached i

l CERYlFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code,Section XI.

l N/A Type Code Symbol Stamp j

"#^

Certificate of Authorization No.

Expiration Date "'^

Signed 7 2 Ee **"

Date Sedw 6A 20 19,,f4 Owner of0wner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Prr>vince ofd1y rE and employed by W f O bI of du//w*/ #

have inspected the components described in this Owner's Report during the period A

NS and state that to to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI, By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

M Commissions YA W V 2dA inspector's signat' re National Board, S' tete, Province, and Endorsements u

Date d JC 19 fl

-. =.

i DockSt Numbers 50-339 Serial Number: 96-629 i

Page 45 of 68 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS j

As Required by the Provisions of the ASME Code Section XI 1

Virginia Electric & Power Company October 3,1996

1. Owner Date Name 5000 Dominion Blvd., Glen Allen, VA 23060 1

1 Sheet of

2. Plant North Anna Power Station Unit Name P.O. Box 402, Mineral, VA 23117 R/R 961373 Rev.1 W.O. 35051946 Addreen Repelr Organization P.O. No., Job No., etc.
3. Work Performed by Virgin a Electnc & Power Company N/A 3

Authorization No.

5000 Dominion Blvd., Glen Allen, VA 23060

"'^

Expiretion Date j

Address i

4. Identification of System s
6. (a) Applicable Construction Code 19 Edition.

Addenda.

Code Case

^S' O O (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19

]

6. Identification of Components Repaired or Replaced and Replacement Components 1

i i

1 ASME Code National

Repaired, Stamped Name of Name of Manufacturer Board Other Year
Replaced, (Yes Component Manufacturer Serial No.

No.

Identification Built or Replacement or No)

Check Valve.

Grane Lvvivue e-ma 2 +11 -6 2 1572 Lv r rJ L

i 0.1.3

)

J l

i i

t

7. Description of Work Performed weld buildup on outside of volve to meet minimum wall requirements.

f

8. Tests Conducted: Hydrostr.c !ij Pneumatic Nominal Operating Pressure 2

Other C r'ressure psi Test Temp.

'F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) Informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

4 (12/82)

This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 l

FORM Nis 2 (Back)

9. Remarks ASME Class 2 Applicable Manufacturer's Data Reports to be ottsched Performed construction code MT and RT examination after repair.

Repair performed in accordance with ASME Section 1111983 Edition.

i CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this *

conforms to the rules of the ASME Code,Section XI.

repent or repiscement N/A Type Code Symbol Stamp N/A N/A Certificate of Authorization No.

Expiration Date i

Signed -

M T J2 fm AM" Date Owner pf Owneri Designee, Title OC O *' 3 19 M CERTIFICATE OF INSERVICE INSPECTION f

1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State I

or Province of ' / W deE and employed by

  1. #* # Of of M/ul ([

have inspected the components described in this Owner's Report during the period I/7/b

/6/M95

. and stete that -

to to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection, kY N-Commissions VA W Y LMA inspector's signature National poord, State,' Province, and Endorsements Date 6# f 19 N i

.. ~-.

Dockst Numbers 50-339 Serial Number: 96-629 Page 46 of 68 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Virginia Electric & Power Company October 1,1996 1.

r Name 6000 Dominion Blvd., Glen Allen, VA 23060 1

1 Address

2. Plant North Anna Power Station 2

Unit Nome P.O. Box 402, Mineral, VA 23117 R/R 96-374 Rev.1 W.O. 351094-01 Address Repair Organization P.O. No., Job No., etc.

3. Work Performed by Virginia Electric & Power Company N/A Type Code Symbol Starnp Name

"#^

Authorization No.

5000 Dominion Blvd., Glen Allen, VA 23060

~

Expiration Date Ad dreas 0* "I

4. Identification of System
5. (a) Applicable Construction Code NAS-2064 86 Edition,N A
Addenda, Code Case gg (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19
6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National
Repaired, Stamped Name of Name of Manufacturer Board Other Year
Replaced, (Yes Component Manufacturer Serial No.

No.

Identification Built or Replacement or No)

Snubber.

Taylor 011 N/A 2-RG-H55-011 A lWU/

Replaceo Inv 10 Kip Snubber.

Taylor 010 N/A 2-RC4155-011 A lWUI Meplacement rio 10 Kip Cap Screw.

T.R. Goldsmith Heat No.

N/A 2-RG-Hb5-Ul l A lyu/

Meplacement no 1 1/2" Dia.

8089294

7. Description of Work __. Replaced large bore snubber and one cap screw after functional test f ailure.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other] Pressure psi Test Temp.

'F NOTE: Supplemental sheets in form of lists, sketches, or drawings rney be used, provided (1) size is 8% in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form, f

4 (12/82)

This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017

i FORM NIS 2 (Back)

9. Remarks ASME Class 1 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code,Section XI, Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A N/A Expiration Date S

T2f b TE**

Owner or 6wner's designee, Title Date

  1. <b8-Y Signed A

19 T (-

CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission inued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of de ede$

and employed by # f, # Uf of Ete//s. / Cf have inspected the components described in this Ow'ner's Report during the period I//IM

  • L /F&

to and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any menner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection, NM M Commissions UA W Y EN4 inspector's Signature National Board, State, Province, and E ndorsements Date Of Y Y 19 N i

1 DockCt Numbers 50-339 Serial Number: 96-629 Page 47 of 68 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Virginia Electric & Power Company October 4,1996 Name 5000 Dominion Blvd., Glen Allen, VA 23060 1

1 SW M

Addreas

2. Plant North Anna Power Station 2

Unit Name P.O. Box 402, Mineral VA 23117 R/R 96-378 Rev.1 W.O. 350524 05 Addrene Fiepair Organization P.O. No., Job No., etc.

3. Work Performed by Virginia Electric & Power Company N/A g

Authorization No.

5000 Dominion Blvd., Glen Allen, VA 23060 N/A Expiration Date Address Feedwater

4. Identification of System
5. (a) Applicable Construction Code NAS-163B 71 jg Edition,##

Addenda, ##

Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19

6. Identification of Components Repelred or Replaced and Replacement Components ASME Code National
Repaired, Stamped Name of Name of Manufacturer Board Other Year
Replaced, (Yes Component Manufacturer Serial No.

No.

Identification Built or Replacement or No)

Checa Valve, Crane CV07002 2-N/A 2-FW-84 1872 Hepaired No 0.1.2 l

7. Description of Work Performed weld buildup on outside of valve to meet minimum wall requirements.

l

8. Tests Conducted: Hydrostatic Pneumatic 0 Nominal Operating Pressure O Other Pressure psi Test Temp.

'F NOTE: Supplemental f,heets in form of lists, sketches, or drowings rney be used, provided (1) size is 3% in. x 11 in., (2) Informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form, e

(12/82)

This Form (E00030) may be obtained f rom the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 I

I

... --. _~._.

I FORM NIS 2 (Back)

9. Remarks ASME Class 2 Applicable Manufacturer's Data Reports to be attached Performed construction code MT and RT examination after repair.

I CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this reDair conforms to the rules of the

' ASME Code,Section XI.

Type Code Symbol Stamp N/A N/A N/A Certificate of Authorization No.

Expiration Date ON*b os Y gg N A

T#f 6m A He Date S6gned owner / ownerYDesignee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of VEME* E and employed by W' J' A I'E of dom 4 ! C F have inspected the components described In this Owner's Repont during the period M*b N2NI to

. and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

)

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this 1

inspection.

U Commissions VA W Y Z#4 Inspector's Signature National Board, Stafe, Frovince, and Endorsements Date ofI V 19 M 1

l 1

i 1

1 1

l

4 DockSt Numbers 50-339 Serial Number: 96-629 Page 48 of 68 FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Vircinia Electric & Power Company Date October 4,1996 Name Snnn nnmininn Blvd.. Glen Allen. VA 23060 Sheet i

of 1

Address

2. Plant North Anna Pawer Station 2

Unit Nome i

P.O. Box 402. Mineral, VA 23117 R/R 96-379 Rev.1 W.O. 350824-04

]

Address Repelr Organization P.O. No., Job No., etc.

3. Work Performed by Virninia Flactric & Power Comoany Type Code Symbol Stamp N/A Authorization No.

N/A 4

5^^^ 0:W:n 9 ed. ?-- ^"- va mn Expiration Date N/A i

Address d

4. Identification of System Feedwater
6. (e) Applicable Construction Cnde satinn 19 71 Edition,N!A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 86 j
6. Identification of Components Repaired or Replaced and Replacement Components g

ASME Code

)<

National

Repaired, Stamped Name of Name of Manufacturer Board Other Year
Replaced, (Yes 4

Component Manufacturer Serial No.

No.

Identification Built or Replacement or No) f Check Valve.

Crane CV11009 N/A 2-FW 126 1971 Repaired No 0.1.1 1

i 4

b i

7. Description of Work o.,_.g

.u m.u m m n n.,.. ;a. n, u.iu.,n m..,

minimi,m wall reauirements.

e

8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other] Pressure psl Test Temp.
  • F d

NOTE: Supplemental sheets in form of lists, sketches, or drawings rney be used, provided (1) size is 8% in x 11 in., (2) Informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

I (12/82)

This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 I

i

- ~.. - - -. -

~.

i FORM NIS 2 (Back) 4

9. Remarks ASME Class 2 Applicable Manufacturer's Data Reports to be attached Performed construction code MT and RT examination after repair.

U

}

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this reoair conforms to the rules of the j

ASME Code,Section XI.

'''''D'*****"'

1 1

Type Code Symbol Stamp N/A i

Certificate of Authorization No.

N/A N/A Expiration Date Signed r 2 C E*** *k '

DM'b e" 4 Date 19 %

Ownegbr Ownefs Des 6gnee, Title

f CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission inued by the National Board of Boiler and Pressure Vessel inspectors and the State i

ha A and employed by M 8' 8 h T or Province of of EMS */ - (T have inspected the components described in this Owner's Report during the period FI'#NI to

  1. 5' N

and state that to the best of rny knowledge and belief, the Owner has performed examinations and taken corrective measures described in this I

Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

T.

M[c-[ M 4

Commissions VA W Z At A Inspector's Signature National Board, State, Province, and E ndorsements Date tid V

19 74 1

a J.

,=

-.1J.

4 4-.___,

+2__

a,h-=

_W_

+

-.;,___14__

J

,.4.1 m-a+*a e.

A qE 4

u__

=

a

,44._=_....

1 Dock 0t Number 50-339 Serial Number: 96-629 Page 49 of 68 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI t

Virginia Electric & Power Company September 30.1996 9, g, Name l

5000 Dominion Blvd., Glen Allen, VA 23060 1

1 SW M

Addreas

2. Plant North Anna Power Station 2

Unit l

Name i

P.O. Box 402, Mineral, VA 23117 R/R 96 380 Rev. 2 W.O. 35051947 Address Repair Orgentastion P.O. No., Job No., etc.

3. Work Performed by Virginia Electric & Power Company N/A Type Code Symbol Stamp Name Authorization No.

5000 Dominion Blvd., Glen Allen. VA 23060

~

Expiration Date Address

4. Identification of System Component Cooling
5. (a) Applicable Construction Code ANSI B31.7 69 Edition,1970 Addenda.

Case 99 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 l

6. Identification of Components Repaired or Replaced and Replacement Components i

ASME Code National

Repaired, Stamped Name of Name of Manufacturei Board Other Year
Replaced, (Yes Component Manufacturer Serial No.

No.

Identification Built or Replacement or No) l Pipe Stone & Webster N/A N/A l b + W-4 2 4 Tv/w Maplacement rvo l

Eng. Corp.

601-02 l

l i

l

7. Description of Work Installed elignment lugs on adjacent piping to aid in the installation of check valve,2-FW-62. Lugs were removed after installation.

N

8. Tests Conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure Other P4ssure psi Test Temp.

'F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in,, (2) informs-tion in items 1 through 6 on this report is incicded on each sheet, and (3) each sheet is numbered and the number of sheets is j

recorded at the top of this form.

i l

(12/82)

This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017

-~

FORM NIS-2 (Back)

9. Remarks ASME Class 2 Applicable Manufacturer's Date Reports to be attached Replacement performed in accordance with ASME Section 1111986 Edition.

i i

l CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this rantacement conforms to the rules of the l

l ASME Code, Section Xl.

l

\\

l Type Code Symbol Stamp N/A j

Certificate of Authorization No.

N/A N/A Expiration Date by bh 3#

19 D Signed 2

TS 6 64'*

Owner of Owner'(Designee, Title Date 1

i CERTIFICATE OF INSERVICE INSPECTION l, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vesset inspectors and the State

(

or Province of b8E and employed by-- #* 8' 8* 7'I of

  1. r M./u' CT have inspected the components described in this Owne 's Report during the period YAdh 9b/N to

. and state that to,the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

N 6' N

~

Commissions VA W Y EMA inspector's signature National Board, State.' Province, and Endorsements Date C<

/

19 h l

l i

s f

a

DockOt Numbers 50-339 j

Serial Number: 96-C?9 j

Page 50 of 68 FORM NIS 2 OWNER'S REPORT FOR REPAlRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI I

s Virginia Electric & Power Company September 30,1996

1. Owner Date j

Name 5000 Dominion Blvd., Glen Allen, VA 23060 1

1 Address

2. Plant North Anna Power Station Unit 4

N.

P.O. Box 402, Mineral, VA 23117 R/R 96 381 Rev. 2 W.O. 350524-06 Address Repair Oreentration P.O. No., Job No., etc.

j

3. Work Performed by Virginia Electric & Power Company N/A TmMSW %

AueoriMon No.

5000 Dominion Blvd., Glen Allen, VA 230 0 Expiration Date Address

""E

4. Identification of System
5. (e) Applicable Construction Code ANSI B31.7 69 O

jg

Edition, Addenda:

Code Case (b) Applicable Edition of Section XI Utillied for Repairs or Replacement 19

6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National
Repaired, Stamped Name of Name of Manufacturer Board Other Year
Replaced, (Yes Component Manufacturer Serial No.

No, identification Built or Replacement or No)

P!pe Stone & Webster N/A N/A I V+ W 4U-TU/U r'.eplacement no -

Eng. Corp.

601-02

7. Description of Work Installed abonment lugs on adjacent piping to aid in the instellation of check valve,2-FW-94. Lugs were removed after installation.

B. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other O Pressure psi Test Temp.

'F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) sire is 8% in. x 11 in., (2) Informs, tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

1 (12/82)

This Form (E00030) may be obtained f rom the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 I

i

. - _ - _.._. _ _ ~ _

FORM NIS 2 (Back)

ASME Class 2

9. Remarks Applicable Manufacturer's Data Reports to be attached Replacement performed in accordance with ASME Section ill 1986 Edition.

i CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this rep cornent conforms to the rules of the ASME Code, Section Xl.

N/A Type Code Symbol Stamp N/A N/A Certificate of Authorization No.

Expiration Date Signed I

TU N'bW Sede~ha 50 Date 199' /o Ownarfr Owner ( Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of V/N""2 and employed by #<f#Ed of Afe//.

ff have inspected the components described in this Owner's Report during the period FIF/SC i/ 2 3/%

. and state that to to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI, By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

i I

da[ N Commissions VA M INA inspictor's Signature National Board, $ tele, Province, and Endorsements Date 8c T /

19 M

Dockst Numbers 50-339 Serial Number: 96-629 Page 51 of 68 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Prr* visions of the ASME Code Section XI Virginia f actric & Power Company September 30,1996 i

r Name 5000 Dominion Blvd., Glen Allen, VA 23060 1

1 3g, g

Addr aos

2. Plant North Anna Power Station Unit __ 2 Nerne P.O. Box 402, Mineral, VA 23117 R/R 96 382 Rev. 2 W.O. 350824-05 Address Repelr Organization P.O. No., Job No., etc.
3. Work Performed by Virginia Electric & Power Company N/A f

Type Code SymMI Step Nome N/A Authorization No.

5000 Dominion Blvd.. Glen Allen, VA 23060 re h Deu Address

4. Identification of System Component Cooling
5. (a) Applicable Construction Code ANSI B31.7 69 Edition,1970 Addenda.

8, 81, 83W, M h Case

{

gg 86 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19

)

l

\\

6. Identification of Components Repaired or Replaced and Replacement Components l

l ASME Code National

Repaired, Stamped Name of Name of Manufacturer Board Other Year
Replaced, (Yes Component Manufacturer Serial No.

No.

Identification Built or Replacement or No) heAacement Pipe Stone & Webster N/A N/A 16" FW-422-1979 No Eng. Corp.

601-02

7. Description of Work installed ahgnment lugs on adjacent piping to aid in the installation of check valve, 2-FW 126. Lugs were remc1ved after l

installation.

I B. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure psi Test Temp.

  • F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) informs.

tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is j

recorded at the top of this form.

J (12/82)

This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 1

FORM NIS-2 (Back)

9. Remarks ASME Class 2 Applicable Manufacturer's Data Reports to be attached Replacement performed in accordance wnh ASME Section ill 1986 Edition.

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this reDlacement Conforms to the rules of the ASME Code,Section XI.

'*A**D'***'"*"'

Type Code Symbol Stamp N/A Certificate of Authorization No, N/A N/A Expiration Date Signed Y

TIT 66-20w Date Idf1 "Ed 19 Fl=

' Owner or Aws,er's Ds44 nee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, hol, ding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State Verf atei and employed by M 1. # D7 or Province of of Mu/A / #

have insp ted the components described in this Owner's Report during the period MAbf MF N to

. and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI, By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective r9easures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions YA W V EEd inspector's Signatur9 National Board, Stat 0, Province, and Endorsements

~

Date Cr N /

19 N

Dock t Numbers 50-339 Serial Number: 96-629 Page 52 of 68 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS I

As Required by the Provisions of the ASME Code Section XI Virginia Electric & Power Company October 2,1996 Name 5000 Dominion Blvd., Glen Allen, VA 23060 1

1 Sheet of Address

2. Plant North Anna Power Station 2

Unit Name i

P.O. Box 402, Mineral VA 23117 R/R 96 383 W.O. 323638-02 Addreen i

Repelr Organization P.O. No., Job No., etc.

)

3. Work Performed by Virginia Electnc & Power Company N/A j

^"

5000 Dominion Blvd., Glen Allen, VA 23060 Expiration Date Address

4. Identification of System
5. (a) Applicable Construction Code ANSI B31.7 69 gg Edition.

Addenda:

Code Case i

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 "

6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National
Repaired, Stamped Name of Name of Manufacturer Board Other Year
Replaced, (Yes Component Manufacturer Serial No, No.

Identification Built or Replacement or No)

Stud structural, unknown unknown n/a e wrwOv 2266o Um, R p; 5.u i4v 3/4' Dia.

5tud Structural, Mackson, Inc.

neat no, nia 4.vrv onO v-22666 i666 Es p; w.....m

,4v

^

3/4" Dia.

M51482

7. Description of Work Replace body to bonnet studs dunng disassembly for NDE.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure psi Test Temp.

'F NOTE: Supplemental sheets in form of lhts, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) informe.

tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/L'2)

This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017

~ _.

.~ ~

. ~.

FORM NIS 2 (Back)

9. Remarks ASME Class 2 Applicable Manufacturer's Date Reports to be attached l

CERTIFICATE OF COMPLIANCE i

We certify that the ristements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A N/A

  1. ^

Certificate of Authorization No.

Expiration Date Signed 1M TO E ti& M.-

Date ocMe 2.

tg 96 Owner /r owner's Feewnee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Y' nee E and employed by //, J. /?M of d u / /=.'l ff have inspected the components described in this Owner s Report during the period FI M N M /h to

. and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirement sithe ASME Code,Section XI.

. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector not his employer j

shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this l

inspection.

8 M

Commissions VA W V I A' A inspector's signature National Board,' State, Province, er d Endorsements Date 8'/ 3 19)T

Dock;t Numbers 50-339 Serial Number: 96-629 Page 53 of 68 FORM NIS 2 OWNER'S REPOR FOR REPAIRS OR REPLACEMENTS As Required by the Prc.ssons of the ASME Code Section XI

1. Owner bon be no c uoi b OA"a Date 10 - 1 P 9 6 Q

Name i

)

We hedin en

. bar en_

Yd 2 4060 Sheet __ I of I

Address

2. Plant $/er A n m,s Pemec 9A.-

unit 1

Nome 4

80. &_r 4c2 0 cer

- VA atii',

d 94-%5 Rev. s v 0. 3512 L o

/ Address Repelt drganiset4n P.O. No., Job No., etc.

2 P. ~,r L ~~.

3. Work Performed by Yhnin be Typ. Code Symboi Stamp JA r;,

Narne iJ Authorization No, d[A bWcm MJ1 N AIL VA 2-3oto Expir. tion o.te Ms) cce e Addreas

/'

4. Identification of System b:e d

cvec r6

5. (a) Applicable Construction Code M SI M l.7 19 O Edition, blo Addenda?P N. N f 8i Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 R C
6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National
Repaired, Stamped Name of Name of Manufacturer Board Other Yeer
Replaced, (Yes Component Manufacturer Serial No.

N o.

Identification Built or Replacement or No) test a.vh. LLal Ms g,

2.c a. u2 U.k. bil No N/A 2-c H-2h 1988 Phkad A/o iYn cue $. BhJl c0 -f 8 9 fp g

g 4

(CW4bsci-c y,k, Rp un Me s

f~

t.

s aw : rfeJ<.4s '

evIia r oinin.

7. Description of Work Mt J:. u t a H nMf e s-in im 1

l

'J J

4 IJ J

8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure 2706 psi Test Temp.

7/O

  • p NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) inforrne, tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82)

This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 REPRINT 12/91

FORM NIS 2 (Back)

Abbe CkSS I

9. Homerks Applic ble Manufacturer's Data Reports to be ett ed Df 3J Mr4 b AM's w [N e f fn Mr e Nw

$U(IIe ut I

RJe<~A m L< +1 RT

.w. [ reod e Wh, hw Re rs udd osNs c.h fe

-H6-/

I

/

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this' ^ *** O Iconforms to the rules tsf the ASME Code, Section Xl.

'*d* M*Ch*"'

Type Code Symbol Stamp

/

Certificate of Authorizat n No $ 8 Empiration Date Signed t

N b

/

Date 2-19 3

Owner or Owner's Des 4ones, Title

/

CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler end Pressure Vessel inspectors and the State or Province of bM and employed by M 5' Il WE of 4/re//c./ b have inspected the components described in this Owner's' Report during the period fd*Tb

/0/14 bl to

. and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the j

examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer f

shall be liable in any menner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

M ee 4*L Commissions MM YMA Inspector's Signature National Board, St(te, Province, and Endorsernents Date Of f Eb 19 Yd

i Docky,t Numbers 50-339 Serial Number: 96-629 4

Page 54 of 68 4

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Virginia Electric & Power Company October 1,1996 Name

-1 5000 Dominion Blvd., Glen Allen, VA 23060 sheet of

~

Addreas 1 Plant North Anna Power Station Unit 2

Name P.O. Box 402, Mineral, VA 23117 R/R 96-387 W.O'. 338732-02 Addreas Repelr Organization P.O. No., Job No., etc.

3. Work Performed by Virginia Electric & Power Company Type Code Symbol Stamp 5000 Dominion Blvd., Glen Allen, VA 23060 Authorization No.

j Expiration Date n/a i

Address s

'* "I j

4. Identification of System i
5. (e) Applicable Construction Code NAS 2064 86 Edition,N/A
Addenda, Code Case 39 A

(b) Applicable Edition of Section XI Utillred for Repairs or Replacements 19 a

6. Identification of Components Repaired or Replaced and Replacement Components 1

4 ASME Code s

National

Repaired, Stamped Name of Name of Manufacturer Board Other Year
Replaced, (Yes Component Manufacturer Serial No.

No.

Identification Built or Replacement or No) i Snubber Taylor 010 N/A 2-EG HL-UGl A las/

Heplacec No M st e r d

ubber Taylor 005 N/A 2-RG-H55-UU1 A TUU/

Heplacement No i

i

7. Description of Work Replaced large bore snubber after functional test f ailure.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure i

Other C Pressure psi Test Temp.

'F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) Informe-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is i

recorded at the top of this form.

4 (12/82)

This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 a

{

m. _

i l

l FORM NIS 2 (Back)

9. Remarks ASME Class 1 Applicable Manufacturer's Date Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl.

'*A*i'**D'*C'**"'

N/A Type Code Symbol Stamp N/A

^

Certificate of Authorization No.

Expiration Date Signed l

N F++=C Date d l

19N Owndr or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, ho,lding a valid commission issued by the Nat'onal Board of Boiler and Pressure Vessel inspectors and the State I

or Province of_Ylff and employed by

  1. e f e # E'I of

//d/8. 2 fT have inspected the components described in this Owner's Report during the period 9/MUI Mb&

to

. and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code.Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

N M

Commissions Y4 W V

  1. MA inspector's Signature National Board, State! Province, and F ndorsements Date Ce Y Y 19 78

i Dockst Number: 50-339 Serial Number: 96-629 Page 55 of 68 FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Vir9 inia Electric & Power Company October 1,1996

1. Owner Date Name 5000 Dominion Blvd., Glen Allen, VA 23060 1

1 Sheet of Address

2. Plant North Anna Power Station Unit Name P.O. Box 402, Mineral. VA 23117 R/R 96-391 W.O. 351110-03 Addrese Repair Oreenizatiori P.O. No., Job No., etc.

p Virginia Electric & Power Company N/A 5000 Dominion Blvd., Glen Allen. VA 23000 Authorization No.

b))

Expiration Date Address

4. Identification of System NAS-2064 86
5. (a) Applicable Construction Code g
Edition, Addenda, Code Case (b) Applicable Edition of See* inn XI Utilized for Repairs or Replacements 19
6. Identification of Components Repaired oi Replaced and Replacement Cornaonents ASME Code National
Repaired, Stamped Name of Name of Manufacturer Board Other Year
Replaced, (Yes Component Manufacturer Serial No.

No.

Identification Built or Replacement or No) snubber s avior via ms 2-nC+i33 GG3 A

^387 Lv;md L

1% kap snubber l ayior vvu im 2-nC+i33 GG3A

^3G7

^.,,;.;;...e...

5 14 Kap

7. Description of Work Replaced large bore snubber af ter functional test failure.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure O Other Pressure psl Test Temp.

'F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on sech sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82)

This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017

FORM NIS 2 (Back)

9. Remarks ASME Class 1 Applicable Manufacturer's Data Reports to be attached i

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacernent conforms to the rules of the ASME Code,Section XI.

repair or replacement N/A Type Code Symbol Stamp

  1. ^

Certifu: ate of Authorizstion No.

Expiration Date Signed -

I T

I M 'A M

  • Date &
  • k 19 N Ownefor OwnePs Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of V"*WA and employed by # d' A #M of Mr//** /

have inspected the components described in this Owner's Report during the period

  • /# f FIJ/U to

. and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificato neither the inspector nor his employer makes any warranty, expressed or implied, concerning the f

examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

M N-Commissions - VA W V EN4 inspector's Signature National Doord, St'ati, Province, and Endorsements Date OcI F 19 F8

Dockst Numbers 50-339 1

Serial Number: 96-629 Page 56 of 68 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 9, g, Virginia Electric & Power Company September 30,1996 Name j

5000 Dominion Blvd., Glen Allen, VA 23060 1

1 g

g Address

2. Plant North Anna Power Station 2

]

Unit l

N.m.

1 P.O. Box 402, Mineral, VA 23117 R/R 96 395 W.0,351458-01 Address Repelr Orgenlaation P.O. No., Job No., etc.

3. Work Performed by Virginia Electric & Power Company N/A Type C@ SW1 SW

"'^

Authorization No, 5000 Dominion Blvd., Glen Allen. VA 23060 ma Expiration Date Address Reactor Coolant

4. Identification of System
5. (a) Applicable Construction Code ANSI B31.7 gg 69 Edition,1970 Addenda. 78, 81, 83W,1 he Case 86 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 1
6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National
Repaired, Stamped Name of Name of Manufacturer Board Other Year
Replaced, (Yes Component Manufacturer Serial No.

No.

Identification Built or Replacement or No)

Snubber Gnnnell 27460 N/A 2-RC-HSS-6 39.01 Unk.

flepiacement No i

I i

l

7. Description of Work Installed bushing on load stud found missing during reinstallation from functional testing.
8. Tests Conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure OtherO Pressure psi Test Temp.

'F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in x 11 in., (2) Informs.

tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is 4

recorded at the top of this form.

4 (12/82)

This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 l

l l

l l

~,

l l

l FORM NIS-2 (Back)

9. Remarks ASME Class 1 Applicable Manufacturer's Data Reports to be attached Replacement performed in accordance with ASME Section ill 1983 Edition.

CERTIFICATE OF COMPLIANCE l

We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Coda, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A

^

Expiration Date Signed

/

T32 &Md/

Date 88r Ab8' 30 19 U Owner o@wner's Cos6enee. Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of VuIdid and employed by MfaI@

of

  1. u//r d

haveinsp!fd ected the components described in this Owner's Report during the period M48/f4 9//l to and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Ud M Commissions VA VJ V EN4 f nspector's Signature National Board, State [ Province, and E ndorsements Date Og 7._

/

19 FI

Dockst Numbers 50-339 Serial Number: 96-629 Page 57 of 68 i

i FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 9, g, Virginia Electric & Power Company d

Date Name 5000 Dominion Blvd., Glen Allen, VA 23060 I

I SWt of l

Address 2 Plant North Anna Power Station Unit 2

1 1

Name l

P.O. Box 402. Mineral, VA 23117 R/R 96'396 W.O. 351459-01 Address Repelt Organitetion P.O. No., Job No., etc.

k

3. Work Performed by Virginia Electric & Power Company N/A Type Code Symbol Stamp

^

Authorization No.

6000 Dominion 81vd., Glen Allen, VA 23060 r#A Expiration Date Address

4. Identification of System Reactor Coolant
5. (a) Applicable Construction Code ANSI B31.7 69 Edition,1970 Addenda, 78, 81, 83(R),11 Q Case gg (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 86
6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National
Repaired, Stamped Name of Name of Manufacturer Board Other Year
Replaced, (Yes Component Manufacturer Serial No.

No.

Identification Built or Replacement or No)

Snubser Gnnnell 16492 N/A 2 RC-HSS-638.01 Unk.

Replacement No

7. Description of Work Installed bushing on load stud found missing during reinstallation from functional testing.
8. Tests Conducted: Hydrostatic Pneumatic 0 Nominal Operating Pressure Other Pressure psi Test Temp.

'F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82)

This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017

FORM NIS 2 (Back)

9. Remarks ASME Class 1 Applicable Manufacturer's Data Meports to be etteched Replacement performed in acen"tance with ASME Section til 1983 Edition.

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this roolacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A

  1. ^

Empiration Date Signed II -

IM EtO'0*

S e.4.k gg h owner orewner's SeeNnee, Title Date CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, hol(ing a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of

/#5'a and employed by # J.#. A l of

  1. er //a * / h have inspected the components described in this Owner's Report during the period FI' */h bat to

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

-]

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damege or a loss of any kind arising from or connected with this inspection.

8 8

Commissions M WV 2D inspector's Sienature National Board, State, Province, and Endorsements Date CC/ /

19 N

Dockst Numbers 50-339

)

Serial Number: 96-629 i

I Page 58 of 68 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI V'rginia Electric & Power Company September 30,1996

1. Owner Name 6000 Dominion Blvd., Glen Allen, VA 23060 1

1 Sheet of Address

2. Plant North Anna Power Station 2

Unit Name

~

P.O. Box 402, Mineral. VA 23117 R/R 96-397 W.O. 351460-01 Address Repair Orgentzstion P.O. No., Job No., etc.

l

3. Work Performed by Virginia Electric & Power Company N/A i

3

^"*

n 5000 Dominion Blvd., Glen Allen, VA 23060 Expiration Date Addrses "I

4. Identification of System
6. (a) Applicable Construction Code ANSI B31.7 69 3g Edition,19 0
Addenda, e Case l

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19

6. Identification of Components Repaired or Replaced and Replacement Components l

a l

ASME l

Code National

Repaired, Stamped l

Name of Name of Manufacturer Board Other Year

Replaced, (Yes Component Manufacturer Serial No.

No.

Identification Built or Replacement or No) l Snubber Gnnnell 27442 N/A 2-MC4'L>uJ /.vu Un k.

neplacement rw 7 Description of Work installed bushing on load stud found missing during reinstallation from functional testing.

8. Tests Conducted: Hydrostatic Pneumatic 0 Nominal Operating Pressure

(

Other O Pressure psi Test Temp.

'F i

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form, (12/82)

This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 a

t

4-A

+,m.

aA^r A

&J 1+M A4 h

---M-4

-#"+

8-4-*

6 b

A

=**

1 l

l i

FORM NIS 2 (Back)

9. Remarks ASME Class 1 Applicable Manufacturer's Dete Reports to be attached Replacement performed in accordance with ASME Section til 1983 Edition.

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this rantm emment conforms to the rules of the ASME Code, Section Xl.

'*i'"*P'*****"'

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed I

TS7 Bath Mr Date I 3d 19 U Owner crewner's Oseignee, Title CERTIFICATE OF INSERVICE INSPECTION f, the undersigned, holding a valid comminion issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of bE"2 and employed by

  1. ,J if fe#.

of ded/aad,&

have inspec the components described in this Owner's Report during the period 9N'Mt PN ' N to

. and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI,

. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

MuI N Commissions W WV LM4 Inspector's signature National Board, S' tete, Province, and Endorsements Date 6<M /

19 M l

Dock:,t Numbers 50-339 Serial Number: 96-629 Page 59 of 68 l

FORM NIS-2 OWNER'S REPORT FOR REPAlRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI J

9, Virginia Electric & Power Company September 30,1996 Nome 5000 Dominion Blvd., Glen Allen, VA 23060 I

I She of Address 2/ Plant North Anna Power Station Unit 2

Name P.O. Box 402, Mineral, VA 23117 R/R 96-398 W.O. 351461-01 Address Repair Oreenization P.O. No., Job No., etc.

3. Work Performed by Virginia Electric & Power Company N/A Type Code Symbol Stamp Authorization No.

5000 Dominion Blvd., Glen Allen, VA 23060 Expiration Date Address

4. Identification of System Reactor Coolant S. (a) Applicable Construction Code ANSI B31.7 gg 69 Edition,1970 Addenda, 78. 81,83(R),11Q g

)

(b) Applicable Edition of Section XI Utilized for Eepairs or Replacements 19 86

6. Identificat6on of Components Repaired or Replaced and Replacement Components ASME Code National
Repaired, Stamped j

Name of Name of Manufacturer Board Other Year

Replaced, (Yes Component Manufacturer Serial No.

No, identification Built or Replacement or No)

Snubber Gnnnell 90089 N/A 2-RC-HSS-63 7.02 Uni.

Replacement No

7. Description of Work Installed bushing on load stud found missing during reinstallation from functional testing.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other O Presrure psi Test Temp.

'F NOTE: Supplemental sheets in form of lists, sketches, or drowings may be used, provided (1) size is 8% in. x 11 in., (2) Informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82)

This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017

1 FORM NIS 2 (Back)

9. Remarks ASME Class 1 Appilcable Manufacturer's Data Reports to be attached Replacement performed in accordance with ASME Section ill 1983 Edition.

I i

1 l

1 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this roolacement conforms to the rules of the ASME Code,Section XI.

'*o*i' or replacement 1

l Type Code Symbol Stamp N/A l

Certificate of Abchorization No.

N/A N/A Expiration Date Signed

/>b^

26 MM8E' hb*b D 19 N Date Owner or@wner's Desidwe, Title I

CERTIFICATE OF INSERVICE INSPECTION i, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of 14Mel and employed by MidEd of

  1. dA*/

t'f have inspected the components described in this Owner's Report during the period M * /M M4MN to

. and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

l By signirig this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the J

examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer i

shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection, N

Commissions W WF M4 Inspectors Signature National Board, State l Province, and E ndorsements Date 6*f

/

1978

DockCt Numbers 50-339 Serial Number: 96-629 1

Page 60 of 68 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1, Owner Viroinia Electric & Power Company Date Octobor 4,1996 Name 5000 onminion mvd.. Glen Allen. VA 23060 Sheet 1

of 1

Address

2. Plant North Anna Power Station 2

Unit Name P.O. Box 402. Mineral, VA 23117 R/R 96-399 Rev.1 W.O. 350524-05 Addreen Repair Organtastion P.O. No., Job No., etc.

3. Work Performed by Virninia Aertric & Power Comoany Type Code Symbol Stamp N/A Authorization No.

N/A SW "r-- b ; *E'd

^""""A "n#'n Expiration Date N'A Address

4. Identification of System Feedwater
5. (a) Applicable Construction Code NAcann 19 71 Edition,N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 86
6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National
Repaired, Stamped Name of Name of Manufacturer Board Other Year
Replaced, (Yes Component Manubeturer Serial No.

No, identification Built or Replacement or No)

Check Valve, Crane CV07002 2 N/A 2-FW-94 1972 Repaired No 0.1.2 i

l 4

)

7. Description of Work n.a mm..a m..g s mamm em in.;a. ne u tv. en onnm m chininn withnut vin!atinct the minimum wall recuirErnefitt.
8. Tests Conducted: Hydrostatic 0 Pneumatic Nominal Operating Pressure O Other O Pressure psi Test Temp.
  • F NOTE: Supplemental sheets in form of lists, sketches, or drawings rney be used, provided (1) stre is 8% in. x 11 in., (2) Informe-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

1 (12/82)

This Form (EOOO30) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017

FORM NIS-2 (Back)

9. Remarks ASME Class 2 t

Applicable Manufacturer's Data Reports to be attached

- Performed construction code MT examination after repair.

CERTIFICATE OF COMPLIANCE l

We certify that the statements made in the report are correct and this reomir conforms to the rules of the ASME Code, Section Xl.

l Type Code Symbol Stamp N/A

{

Certificate of Authorization No.

N/A N/A Expiration Date Signed IM 3"ST Ea t M ee.-

O Y

E5 Date 19 owned r owner's DesWnee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersign 4, holding a valid commission issued by the National Board of Boller and Pressure Vessel inspectors and the State or Province ofaAMrf15 and employed by Ml8Id of

  1. cM/TI/ ef have in acted the components described in this Owner's Report during the period 9A*//M

>I and state that to to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions V4 4W

~LNA Inspector's Signature National Board, State! Province, and Endorsements Date 6'( N V 19 N

Dock 2t Numbers 50-339 Serial Number: 96-629 Page 61 of 68 FORM NIS-2 OWiJER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI I

Virginia Electric & Power Company October 1,1996

1. Owner Date Name 5000 Dominion Blvd., Glen Allen, VA 23060 1

1 Sheet of Addreas

2. Plant North Anna Power Station 2

Unit Name P.O. Box 402, Minerol, VA 23117 R/R 96-421 Rev.1 W.O. 351737-01 Address Repair Oreenization P.O. No., Job No., etc.

3. Work Performed by Virginia Electric & Power Company N/A g

Auth rizati n No.

5000 Dominion Blvd., Glen Allen, VA 230 Expiretion Date l

ea t r lant

4. Identification of System
5. (a) Applicable Construction CodeNAS-2064 86 gg
Edition, Addenda.

Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 I

6. Identification of Components Repaired or Replaced and Replacement Components ASME l

Code National

Repaired, Stamped Name of Name of Manufacturer Board Other Year
Replaced, (Yes Component Manufacturer Serial No.

No.

Identification Built or Replacement or No) i Snubber Taylor 005 N/A 2-ML-Mdd-UU16 Ivct neplacec nu 19 Kip Snubber Taylor 005 N/A Z-ML-Mdd UU I L IUDI neplacement ng 19 Kip Cap Screw, T.R. Goldsmith Heat No.

N/A 4-ML-Mdd-UU I L IUDS ne p6a va mc m iw 1 1/2" Dia.

8089294

7. Description of work Replaced large bore snubber and cap screw after functional test failure.
8. Tests Conducted: Hydrostatic Pneumatic 0 Nominal Operating Pressure Other Pressure psi Test Temp.

'F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) Informe.

tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82)

This Form (tE00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017

FORM NIS 2 (Back)

9. Remarks ASME Class 1 Applicable Manufacturer's Data Reports to be attached 4

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this reolacement conforms to the rules of the ASME Code, Section Xl.

'***'D'***'"*"'

i Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A N/A Expiration Date Signed DT h bear Date d'

b Y 19 Owner or owner'fDes6pnee, Title r

CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holping a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of VM*

E and e nployed by

  1. '# A ##1 of Ncdb / ff have i ed the components described in this Owner's Report during the period d M M' F

to and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection, d*

N Commissions NYM 2M4 inspector's S6enature National Scard,~ State, Province, and Endorsements l

Date 667 F 19 N l

f I

I I

l I

Dock",t Number: 50-339 Serial Number: 96-629 Page 62 of 68 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Virginia Electric & Power Company October 1,1996 r

Name 5000 Dominion Blvd., Glen Allen, VA 23060 1

1 t

3 g

Addreas j

2. Plant North Anna Power Station Unit 2

j Name P.O. Box 402, Mineral, VA 23117 R/R 96 423 W.O. 350663-03 Address Repair Organization P.O. No., Job No., etc.

3. Work Performed by Virginia Electric & Puwer Company N/A Type Code Symbol Stamp Name

"'^

A"Ih*'I#8'30" NO-j 5000 Dominion Blvd., Glen Allen. VA 23060 on Date l

Address

4. Identification of System Quench Spray
5. (a) Applicable Construction Code ANSI B31.7 69 Edition,1970
Addenda,
8. 81, 83W,1 be Case jg (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19
6. Identification of Components Repaired or Replaced and Replacement Components j

ASME Code National

Repaired, Stamped Name of Name of Manufacturer Board Other Year
Replaced, (Yes Component Manufacturer Serial No.

No.

Identification Built or Replacement or No)

Stud Structural, Unknown Unknown N/A 2-51140 Unk.

Meplaceo No 5/8" Dia.

Nut, Unknown Unknown N/A 2-b1-14U Unn.

Heplaceo no i

5/8" Dia.

Stud Structual, Mackson, Inc.

Heat No.

N/A 4 bi-14U IUUD Meplacement tva 5/8" Dia.

639196

Nut, Mackson. Inc.

Heat No.

N/A 251140 1996 Replacement No 5/8" Dia.

05662GJ j

i

7. Description of Work Replaced body to bonnet bolting during replacement of flange gasket.
8. Tests Conducted: Hydrostatic Pneumatic C Nominal Operating Pressure O Other Pressure psi Test Temp.
  • F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82)

This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 l

FORM NIS 2 (Back)

9. Remarks ASME Class 2 Applicable Manufacturer's Date Reports to be ettsched i

l CERTIFICATE OF COMPLlANCE We certify that the statements made in the report are correct and this roolacement conforms to the rules of the ASME Code, Section Xl.

i Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A N/A Expi.etion Date Signed I T FadA#e-Date O

A I 19 N Owner ordwner's tree 6snee, Title 1

i CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Ye ese E and employed by #< d A DE -

of

  1. w//n* /-

have inspected the components described in thl Owner's Report during the period M2FIP4 PI*

I to and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI, By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report, Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

A Commissions J A Y,t y L A6 4 anspector's sienature Nationel Board, State,' Province, and Endorsements Date OCI 4 19 #4

4 DockOt Ntnab., s 50-339 i

Serial Number: 96-629 i

Page 63 of 68 FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner %ginia Electnc & Power Company October 3.1996 Date 1

Name 5000 Dominion Blvd. Glen Allen, VA 23060 sheet I

of 1

Address

2. Plant North Anna Power Station Unit 2

Nome P.O. Box 402, Mineral. VA 23117 R/R 96-424 W.O. 331779-03 Address Repelt Oreenization P.O. No., Job No., etc.

3. Work Performed by Virginia Electric & Power Company Type Code Symbol Stomp N/A Authorization No.

l 5000 Dominion Blvd., Glen A!!sn, VA 23060

"^

Expiration Date Address

4. Identification of System Safety injection 2
5. (a) Applicable Construction Code ANSI B31.7 jg69 Edition,1970 Addenda. 78. 81. 83(R) 11h Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1986 4
6. Identification of Components Repaired or Replaced and Replacement Components l

ASME Code j

National

Repaired, Stamped j

Name of Name of Manufacturer Board Other Year

Replaced, (Yes j

Component Manufacturer Serial No.

No.

Identification Built or Replacement or No) r Support Stone & Webster N/A N/A 2 SI-R-5 Unk.

Replaced No

)

]

Eng. Corp Support Stone & Webster N/A N/A 2-SI-R-5 1996 Replacement No Eng. C >rp

7. Description of Work Cut, removed, and reinstall pipe support 2-St-R-5 on 12050-WMKS-104C 2 to remove 2-SI-MOV-28628.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure psi Test Temp.

'F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used,'provided (1) size is 8% in. x 11 in., (2) informe-tion in itema 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recordM % tt e top of this form.

r (12/82)

This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017

l i

l r

l l

\\

FORM NIS-2 (Esck) i 9, Remarks ASME Class 2 Applicable Manufacturer's Data Foports to be attached

\\

Pa n,....

A w,e seL tr v r-3 7,e4.neJ CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of tne ASME Code,Section XI,

''''*8'***"'*"*

N/A Type Cd Symbol Stamp MA

^

Certificate of Authorization No.

Expiration Date Signed TT M ***

Date d

  • b 3

_19 N Owner or QGvner's De6pnee, Title i

i CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, hol, ding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of Y'yM and employed by h Ja # IM of Mu/A.-/ CT have inspected the components described in this Owner's Report during the period AMh to W

fl

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI, By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective meesures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

  1. o Ms Commissions W VJ V EN4 inspector's s6gnature National Board, State, Province, and Endorsements Date C< f 3 19 N

t Dockst Numbers 50-339 Serial Number: 96-629 i

Page 64 of 68 FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

[

As Required by the Provisions of the ASME Code Section XI Virgirua Electric & Power Company October 3,1996 N.m.

5000 Dominion Blvd., Glen Allen, VA 23060 1

1 Address

2. Plant North Anna Power Station 2

l g;,

Name a

P.O. Box 402. Mineral, VA 23117 R/R 96-428 W.O. 350813-01 Addreas Hopelt Oreenization P.O. No., Job No., etc.

3. Work Performed by Virginia Electric & Power Company N/A

)

Type Code Symbol Stamp Name nf3 5000 Dominion Blvd., Glen Allen, VA 23060 Authorization No.

a Deu j

4 Address

4. Identification of System i

j S. (a) Applicable Construction Code ANSI B31.7 69 39 Edition]9 0 Addenda; Code Case

}

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 J

i

6. Identification of Components Repaired or Replaced and Replacement Components i

1 ASME 4

Code National

Repaired, Stamped Name of Name of Manufacturer Board Other Year
Replaced, (Yes Component Manufacturer Serial No.

No.

Identification Built or Replacement or No)

J

~

1 Stud Structural.

Unknown Unknown N/A 4-Ub MU V-4U4 A UnK.

Me;;3acea rug 1/2" Dia.

Nut, Unknown Unknown N/A 4.UFMUV-4U4A Unn.

neptacca nu 1/2" Dia.

5tud Structual.

Energy steel Neat No, rCA 4-U:>-MU V-4V4 A 1U07 nc pa -s m hv 1/2" Dia.

6051609

Nut, Mackson, Inc.

Heat No.

N/A 2 05-MUV-202A 1 W Wt>

Heplacement No 1/2" Dia.

97364 i

i

7. Description of Work Replaced bolting during repair of valve seat for leakby.
8. Tests Conducted: Hydrostatic 0 Pneumatic Nominal Operating Pressure 3

4 Other Pressure psi Test Temp.

'F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

1 j

(12/82)

This Form (E00030) may be obtained from tne Order Dept., ASME,345 E,47th St., New York, N.Y.10017

-- --.. - ~ -

j 4

FORM NIS 2 (Back)

9. Remarks ASME Class 2 i

Applicable Manufacturer's Data Reports to be attached i

l CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this rantacament conforms to the rules of the i

ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed

/MEh N b,'aece Ownef or Own4Ps Designee, Title Date d

  1. +

3 19 N

]

CERTIFICATE OF INSERVICE INSPECTION 1, the undersig9ed, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State Ah_

and employed by #9

  • d I/a
  • 8 1 lafe
  • P"*WS or Province of m

of N M i-/ ff have nspected the components described l

in this Owner's Report during the period MuhY

? RM6 to

. and state that to the best of my knowledge ced belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordanct ntth the requirements of the ASME Code,Section XI.

. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and correctbe measures described in this Owr.tr's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or propers / damage or a loss of any kind arising from or connected with this inspection, N4 N

Commissions VA W V ZNA Inspector's signature National Board, State, Province, and E ndorsements i

Date 6(/ 3 19 h 4

j 4

)

Dockst Numbers 50-339 Serial Number: 96-629 Page 65 of 68 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Virginia Electric & Power Company October $.

996

1. Owner Date Name 5000 Dominion Blvd., Glen Allen, VA 23060 1

1 Sheet of Address

2. Plant North Anna Power Station Unit Name P.O. Box 402, Mineral. VA 23117 R/R 96-429 W.O. 350813-02 Address Repair Oreenization P.O. No, Job No., etc.
3. Work Performed by Virginia Electric & Power Company N/A Type Code Symbot Stamp Name Authorization No.

5000 Dominion Blvd., Glen AIIen, VA 23060 pe ate Address O"*"*h SP#

4. Identification of System ANSI B31.7 69 O
5. (a) Applicable Construction Code gg
Edition, Addenda, Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacement 19 "
6. Identification of Components Repaired or Replaced and Replacement Components l

ASMC Code National

Repaired, Stamped Name of Name of Manufacturer Board Other Year
Replaced, (Yes Component Manufacturer Serial No.

No.

Identification Built or Rep acement or No) stud structural, unknown unnnown mm 2-G5-iviGv 2026 Uni.

Gow;.wed N-1/2" Dia.

Nut, Unknown unnnown nm 2-G54.dGV 2G26 Uni.

E v;.w J N.

1/2* Dia.

5tua structual, energy stees ricat no.

iwA 2-G3-ieGV-2G26 IGG 7 C-v; a.. -

N.

1/2" Dia.

6051609

Nut, Mackson. Inc.

Heat No.

N/A 4-UFMuv 4v4u i536 nupiausmwn6 isu 1/2* Dia.

97364

7. Description of Work Replaced bolting dunng repair of volve seat for leekby.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure psi Test Temp.

'F NOTE: Supplemental sheets in form of lists, sketches, or drewings may be used, provided (1) size is 8% in x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82)

This Form (E00030) may be obtained f rom the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 j

I l

i i

i FORM NIS 2 (Back)

9. Remarks ASME Class 2 Applicable Manufacturer's Data Reports to be atteched CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this roolacement conforms to the rules of the ASME Code,Section XI.

'#*D***"'

Type Code Symbol Stamp __ N/A Certificate of Authorization No.

N/A N/A Expiration Date Signed

//

.T 1T E'ese Date oc4 k 3 gg N Ownepbr Own#s Designes, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of V"*A E and employed by */ J 8 bl of NuM I have inspected the components described in this Owner's Report during the period fdfb ON to

_ and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

N Ns Commissions V4 YJ V IM A inspector's signature National Board, State, Province, and E ndorsements

~

Date Oc Y 7 19 M

Dockst Numbers 50-339 Serial Number: 96-629 Page 66 of 68 FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Virginia Electric & Power Company October 1,1996 g,

Name 5000 Dominion Blvd., Glen Allen, VA 23060 1

1 3

g Address

2. Plant North Anna Power Station 2

Unit Name P.O. Box 402, Mineral, VA 23117 R/R 96435 W.O. 35174841 Ad dreen Repelf Organization P.O. No., Job No., etc,

3. Work Performed by Virginia Electric & Power Company N/A Type Code Symbol Stamp Name 5000 Dominion Blvd., Glen Allen, VA 23060 Authorization No.

a ete Addreas Chemical and Volume Control

4. Identification of System
5. (a) Applicable Constrr.ction Code ANSI B31.7 69 Edition,1970 Addends-

,81,83W. M b Case gg 86 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19

6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National
Repaired, Stamped Name of Name of Manufacturer Board Other Year
Replaced, (Yes Component Manufseturer Serial No.

No.

Identification Built or Replacement or No)

Stud Structural, Unknown Uriknown N/A 2-CH-MUV Z45 /p Unk.

Heplaceo No 3/4" Dia.

[

Not, Unknown Unknown N/A

.H-MUV-225/p UnK.

Neplaceo no

~

3/4" Dia.

Stud Structual, Mackson, Inc.

Heat No.

N/A 4-(,N-MV V-4 4 5 / D 1UUD Meplacement ng 3/4" Dia.

56678 Nut.

Mackson. Inc.

Heat No.

~

N/A 2-CH-MOV-225 7 B 1886 Replacement No 3/4" Dia.

16409Ji 7,' Description of Work Replaced botting during disassembly to NDE valve seats.

8. Tests Conducted: Hydrostatic 0 eaeumatic 0 Nominal Operating Pressure Other O Pressure
si Test Temp.

'F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) informs-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82)

This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 i

)

. _... - - - - = -.. - _ - -

FORM NIS 2 (Back)

9. Remarks ASME Class 2 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code,Section XI.

'*D'***"'*"'

N/A Type Code Symbol Stamp N/A Certificate of Authorization No.

Expiration Date " ^

Signed N

b/*N Date Oc A

/

19 N Owner # Ownerd Designee, T6tle CERTIFICATE OF INSERVICE INSPECTION f, the undersigned, holding a valid comminion issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of V"%*d and employed by

  1. ' I # M of
  1. re//o.-/- d have inspected the components described in this Owner's Report during the period Mub PI*

I and state that to to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI, By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

)

1 Um 8

Commissions - VA YJ V

_$ M 4 Inspector's signature National Board, State,}rovince, and Endorsements Date 6tY Z 19 N 1

Dockst Numbers 50-339 Serial Number: 96-629 Page 67 of 68 FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner 6 Ehk< & fLtc G,,o-O,te io-2 4-9 c a

N arn.

1 s

9t f MM 04 bt GLA k T5d O Sheet I

69 of I

/ Addreas

/

2. Pir r.t er Ann Peute SJ,n-
uni, 1

Narne f/t % m M 0, 3= M 39-eI P.c 6 40 hr~l VA un7

/

Address' Repelt Oreenlaation P.O. No., ~ ob No., etc.

I J

3. Work Performed by Yifma Ele < n s k E wtf (emau Type Code Symbol Stamp - YI

)

I d

Authorization No.

MA C h r bo m u,.., F>l<1 Clu, M leu. VA 12 eL o Empiration osie

  1. 4 i

/ Address I

/

Tw 'i + c-

4. Identification of System o sa mW a

~

t mtg.% s c.s-c% ui

5. (a) Applicable Construction Code 461 DO 19 O Edition, f I7D Addenda,79 61, &@) 0 5 Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 N j
6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National
Repaired, Stamped Name of Name of Manufacturer Board Other Yeer
Replaced, (Yes Component Manufacturer Serial No.

No.

Identification Built or Replacement or No) f (kd VM. Vde d/+

p-sI-In u, t 94FW No

7. Description of Work bd JMtsS mt c hm S?

o e

i'L o OftVt I

No I

J

8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other O Pressure psi Test Temp.

'F NOTE: Supplemental sheets in form of lists, sketches, or drowings may be used, provided (1) size is 8% in. x 11 in., (2) Informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82)

This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 REPRINT 12/91

~.

FORM NIS 2 (Back)

AME Cl%3 1

e. R.merus
  • oon ie uenotecto,e, s osta neoort to t,e e,tecned LP w%kh,'e w ht< mckw: u k1st)< l 1 < c f or ~.

J e

A99fcy. O 016 11 CERTIFICATE OF COMPLIANCE I

We certify that the statements made in the report are correct and this f*-DM I conforms to the rules of the ASME Code, Section X1,

"'d'***'"*"'

Type Code Symbol Stamp

/

Certificate of A thorize ' n No 0 Expiration Date I

/

/'

/

Signed N ' bW(

Date 8

+(

b 7b owner or OJvner's Deseente, Title G

~ 19 i

I CERTIFICATE OF INSERVICE INEPECTION 4

1, the undersigned, holding a valid commission issued by th6 hetional Board of Boiler and Pressure Vessel inspectors and the State or Province of Y"b W employed by M I E l'1 of

/A'Y r-6 7-have inspected the componente doecribed in this Owbr's R rt during the period

/ C/*'Nb V!PI to

/

. and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI, By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shell be lieble in any menner for any personal injury or property damage or a loss of any kind arising from or connected with this Inspection.

$r.

/h* -

Commissions A'A WN P MA N Y2Y Inspector's Signature Net 60nel Board, State, Province, and Endorsements Date A42

  • W 19 J' C

l DockOt Numbert 50-339 Serial Number: 96-629 Page 68 of 68 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Ownerkrh be riu We( (om e u Date

/63.S

(

a Nome j

sm Dr.,4, Al. Gk AIL VA 2se6 e 1

Sh.et of 1

/ Addreas

2. Plant de Am Po,< Shb unit 1

Name P.o.Sc1 vo2. M;w,c,j. VA 2 ui7

.R/R %-W 8. W. e ets.2 %7 - o s Address Repair Oreenlastion P.O. No., Job No., etc.

3. Work Performed byYrobia Elehric k how (m-Type Code Symbol Stamp dd Authorization No.

h2L fecc bemiMm bv __htwA.Ilm VA 2seLo Empi,etion Date

,WA 4

/ Address

/

4. Identification of System (hea (a

H) i e m e.

r.

5. (e) Applicable Construction Code N E 3IO 19 $9 Edition, IDO AddendeOf bl EYP1 IIS Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 M a
6. Identification of Components Repaired or Replaced and Replacement Components i

ASME I

Code National

Repaired, Stamped Name of Nome of Manufacturer Board Other Year
Replaced, (Yes 4

Component Manufacturer Serial No.

No.

Identification Built or Replacement or No) b,ck C. h 5 L (45

$404B-150e? h 1-CH-RV 2%8 M')9

<md ho Bld \\/.Je Alml Cred M155-sisc A/[4 2-c H-RV ne:S nh hs,{ No 3

4 f

7. Description of Work ft hk 0

ut w f e is e es V Vt i n. c.' S h 6 7 r.

l a

8. Tests Conducted: Hydrostatic Pneumatic 0 Nominal Operating Pressure Other Pressure l6 psi Test Temp.

fVO

  • P NOTE: Supplemental sheets in form of lists, sketches, or drawings rney be used, provided (1) size is 8% in. x 11 in., (2) informe-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82)

This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 REPRINT 12/91

i bob (

b$ 1

9. Remarks Applicebte Manufacturer's Date Reports to be attached l

CERTIFICATE OF COMPLIANCE I

We certify that the statements made in the report are correct and this (8 9 WW2 conforms to the rules of the ASME Code,Section XI.

'***I'"*88***'"*"*

l Type Code Symbol Stamp Certificate f Autho ization Empiration Date r

/

/

Signed 1 d be bNI Date r ~~a

-f I tg )

Owne(dr Owner's Deelenes, Title J

CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of

- 12 and employed by # l.# l'O of A4M/o a / #

have inspected the components described In this Ow'ner's Report during the period

> C/i YEd hJ' and state that to to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither tM Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

mci @f,

Commissions VA W V MA s

Inspector's Strature National Board, State, Province, and Endorsements Date Nw 7'

19 M