ML20132D285

From kanterella
Jump to navigation Jump to search

Requests Addl Info Re 960405 Application to Renew Matl License SNM-1097 within 30 Days
ML20132D285
Person / Time
Site: 07001113
Issue date: 12/17/1996
From: Lamastra M
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To: Reda R
GENERAL ELECTRIC CO.
References
TAC-L10079, NUDOCS 9612190297
Download: ML20132D285 (4)


Text

-

December 17, 1996 Dr. Ralph J. Reda Manager, Fuels and Facility Licensing General Electric Company P.O. Box 780, MC J26 Wilmington, NC 28402

SUBJECT:

LICENSE RENEWAL - REQUEST FOR ADDITIONAL INFORMATION (TAC NO. L10079)

Dear Dr. Reda:

This refers to your application dated April 5,1996, requesting renewal of Material License SNM-1097. Our review of Chapters 1, 2, and 3, has identified additional information that is needed before further action can be taken on your renewal.

The additional information should be provided in the form of responses to the individual comments, as appropriate, or as revised pages to the application, within 30 days of the date of this letter. Please reference the above TAC No.

in future correspondence related to the renewal request.

If you have any questions, please cal me at (301) 415-8134.

Sincerely, Original signed by:

Michael Lamastra Licensing Section 2 Licensing Branch Division of Fuel Cycle Safety and Safeguards, NMSS Docket 70-1113 License SNM-1097

Enclosure:

Additional Information i l

gn 05 i DISTRIBUTION: (Control No. 2700)

Docket 70-1113 PUBLIC NRC File Center Region II NMSS r/f FCSS r/f FCLB r/f CBassett, RII GTroup, RII

G:\geadd.ml]

0FC FCLB i.h L I FCLB [., FCl.B f.

5 p- . ,

,- u p , w NAME MLamastra/nt PShea d b> 'GPancjburn DATE 12/Tl /96 12//ld /96 12//7 /96 0FFICAL RECORD COPY 9612190297 961217 PDR ADOCK 07001113 me EE WE WY C PDR

s@ REQvg i UNITED STATES s* j NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555 4001

% , j ,, # December 17, 1996 Dr. Ralph J. Reda Manager, Fuels and Facility Licensing General Electric Company P.O. Box 780, MC J26 Wilmington, NC 28402

SUBJECT:

LICENSE RENEWAL - REQUEST FOR ADDITIONAL INFORMATION (TAC N0. L10079)

Dear Dr. Reda:

This refers to your application dated April 5,1996, requesting renewal of -

Material License SNM-1097. Our review of Chapters 1, 2, and 3, has identified I additional information that is needed before further action can be taken on your renewal.

The additional information should be provided in the form of responses to the I individual comments, as appropriate, or as revised pages to the application, within 30 days of the date of this letter. Please reference the above TAC No.

in future correspondence related to the renewal request.

If you have any questions, please cal me at (301) 415-8134.

Sincerely, p s ._ , =-

Michael Lamastra Licensing Section 2 l Licensing Branch Division of Fuel Cycle Safety 4 and Safeguards, NMSS Docket 70-1113 License SNM-1097

Enclosure:

Additional Information

s. ,

s l

5' i i i

J SPECIFIC COMMENTS AND ADDITIONAL INFORMATION REQUIRED GE-WILMINGTON RENEWAL APPLICATION l CHAPTER 1 GENERAL INFORMATION

1. Page 1.10, Section 1.3.1.2. This section should be expanded to include a commitment that accident scenarios are developed when any changes to the process are planned / implemented that may impact a structure, system, or component important to safety, even if does not involve a new technology.

2 .- Section 1.3.3, page(s) 1.11-1.13. Describe uses intended for this inaterial and provide the following:

a. Information_regarding amount (s) and concentration (s) of hydrofluoric acid transferred, if varied, because generation of the acid depends on production,'then provide range,
b. A pathway analysis that shows that this material does not enter any commodity designated for ingestion or inhalation nor is it released to the environment. Include secondary pathway analysis of residues.
c. A description of the shipping containers,- such as size, material, liners, etc.
d. A commitment to keep records for sampling and measurement of uranium concentrations prior to shipment.
e. GE has been transferring nitrate-bearing liquids and CaF2 to buyers in the paper and steel manufacturing business. However, ,

very little information is provide for these activities in the renewal application. Therefore, the same information requested .

above for the hydrofluoric acid should be provided for these 1 materials as well.

J i

CHAPTER 2 ORGANIZATION AND ADMINISTRATION

1. General; comment - overall, most positions have the qualifications (especially experience) decreased from the existing license. You should-demonstrate or explain why such a decrease in the over-all experience of the staff does not adversely the safety of operations.

ENCLOSURE a -

e ,

2

2. Page 2.10, Section 2.3.1. Make the following commitments:
a. The facility Safety Review Committee (SRC) shall include experts on operations and all safety disciplines (criticality, radiological, chemical and fire). The members and alternate members of the SRC shall have an academic degree in an engineering or physical science field and shall be appointed by the Facility Manager,
b. The SRC shall have review meetings within 60 days after an incident which is reportable to the NRC. These meetings may be combined with regular meetings.
c. Following the reportable event, the Committee shall review the incident causes, responses, and both specific and generic corrective actions to ensure that resolution of the problem is implemented.
d. A written report of each SRC meeting and review shall be forwarded to the facility manager and appropriate function manager (s) within 30 days and be retained for the duration of the facility.
3. Define " area" and identify how many areas there are in the operations.

-4. Provide more detail.of-.the chain-of-command between " product:line management" and " area manager." Explain if one or more product line manager is responsible for one or more area managers. In addition to providing more detail in these functions, use diagrams as appropriate.

CHAPTER 3 CONDUCT OF OPERATIONS

1. General
a. Include description how they meet the Branch Technical Positions for Management Controls and Operations QA.
b. In Section 3.1, the you uses the terms "important to safety" and

" safety-related systems- and components" but neither term is

-defined. Section 3.3.2 uses a different term " Safety Structures, Systems and Components" which may or may not be the same as

" Safety-related" or "important to safety."

3.1.4. Clarify if Functional Test Instructions (IFIs) are included in Document Control.

3.2.1 Clarify if Scheduled-Preventive Maintenance applies to instruments or equipment designated as " Active Engineered- Controls"'are included.

3.2.2 Same comment as-3.2.1.

i l -

3 3.4 Clarify if training meets requirements of 10 CFR 19.12 for employees.

Define how the training meets ANSI 8.20 for nuclear criticality safety training.

3.4.2 Clarify what sort of refresher training or training following changes will be provided to operators.

3.6.3 Specify a minimum frequency for independent audits.

3.7 Clarify how the requirements of NRC Bulletin 9101 - are incorporated inte Incident Investigations.

3.9.2 Include a generic statement about the licensee's policy concerning mandatory compliance with the requirements of procedures.

Also, specify a minimum frequency for periodic review of operational procedures if they are not changed.

2. Page 3.6, Section 3.4. Add the following: (a) training in 10 CFR Part 19; (b) environmental protection and; c) risks involved in receiving chronic low level exposure to soluble uranium compounds and byproducts of reaction with ambient moisture, as well as other chemicals involved in processes under the NRC regulatory confines.
3. Page 3.8, Section 3.6.1.
a. QA personnel should be included in safety audits.
b. Audited organization will inform auditing organization of schedule for completion of corrective actions. Notification should be given within 30 days of the audit and tracked to completion by individual designated by the QA group. l
4. Page 3.9, Section 3.6.3, first paragraph.

GE is involved in activities handling radioactive material in chemical processes. Independent audits must be conducted for areas covered under j the ISA. The applicant's limitation of the independent audits to only l tm areas, the radiation and criticality safety programs, severely hinders the purpose of audits and ignores a_tivities significant to l plant safety. 1

5. Page 3.11, Section 3.8, second paragraph.

l If a list of records is to be provided, it should specifically identify retention periods and it should be a more comprehensive listing than provided in the application.