May-7, 1985 Docket No. 50-285 DISTRIBUTION:

' N PMKreutzer NRC-PDR ACRS +10 Mr. R. L. Andrews.

ORB #3 RDG

. Gray' File Division Manager - Nuclear Production HThompson TBournia Omaha:Public Power District 0 ELD JKramer 1623.Harney Street EJordan Omaha, Nebraska 68102 BGrimes JPartlow

Dear Mr. Andrews:

EGTourigny

SUBJECT:

-DRAFT TECHNICAL EVALUATION REPORT (TER)-FOR-SALEM ATWS ITEM 1.2 (GENERIC LETTER 83-28)

Re:

Fort Calhoun Station, Unit 1 The staff has completed a~ preliminary review to assess the completeness and adequacy of licensee responses to Generic Letter 83-28 Item 1.2.

For the Fort Calhoun Station, your' response was found to be incomplete in two of the areas evaluated.

-The enc osed TER provides a technical evaluation representing the staff's l

initial judgment of the areas evaluated. Pen and ink changes have been made to the TER?by your project manager to make the wording consistent with our approach.

In~ order to preserve our present review schedule, we would appreciate your cooperation in obtaining additional information that will pennit us to complete our review..It would' appear that the needed information on your facility could be.obtained by telephone conference within one week of your receipt of the' DRAFT TER. Your project manager will be working with you to arrange an acceptable time to conduct the necessary conference calls.

~The reporting and/or recordkeeping requirements contained in this letter affect' fewer than 10: respondents; therefore, OMB clearance is not required under P.L.96-511.

Sincerely, i

e i

g 53g g g$ $ 85 James R. Miller, Chief PDR Operating Reactors Branch #3 p

Division of Licensing

Enclosure:

DRAFT TER on Salem

.ATWS Item 1.2 cc w/ enclosure See next page ORBf QL

- ORB #3: Dig 3r.r[

ORf#3:DL 4

.P ter EGTourigriy:c d gb1RMiller 5/

85 5/ 7 /85 (5/}/85

~

SAIC-85/1515 REVIEW OF LICENSEE AND APPLICANT RESPONSES TO NRC GENERIC LETTER 83-28 i

(Required Actions Based on Generic Implications of Salem ATWS Events). Item 1.2

" POST-TRIP REVIEW: DATA AND INFORMATION CAPABILITIES" FOR FORT CALHOUN STATION, UNIT 1 (50-285)

Technical Evaluation Report Prepared by Science Applications International Corporation 1710 Goodridge Drive McLean, Virginia 22102 Prepared for U.S. Nuclear Regulatory Commission Washington. D.C. 20555 Contract No. NRC-03-82-096

~

FOREWORD This report contains the technical evaluation of the Fort Calhoun Station, Unit I response to Generic Letter 83-28 (Required Actions Based on Generic Implications of Salem ATWS Events)

Item 1.2 " Post Trip Review:

Data and Information Capabilities."

For the purposes of this evaluation, the review criteria, presented in part 2 of this report, were divided into five separate categories. These are:

1.

The parameters monitored by the sequence of events and the time history recorders, 2.

The performance characteristics of the sequence of events recorders, 3.

The performance characteristics of the time history recorders, 4.

The data output format, and 5.

The long-term data retention capability for post-trip review material.

All available responses to Generic letter 83-28 were evaluated. The plant for which this report is applicable was found to have adequately responded to, and met, categories 2, 3 and 4.

,a The report describes the specific methods used to determine the cate6 gorization of the responses to Generic Letter 83-28.

Since this eva ation report was intended to apply to more than one nuclear power plant s cifics regarding how each plant met (or failed to meet) them are not presented.

Instead, the evaluation presents a categorization of the responses according to which categories of Maare satisfied and which are not.

The evaluations are based on specific criteria (Section 2) derived from the requirements as stated in the generic letter, w cd'h

TABLE OF CONTENTS Section Page Introduction.........................

I 1.

Background..........................

2 2.

Review Criteria.......................

3 3.

Evaluation................-..........

8 4.

C'onclusion..........................

9 5.

Re fe re nc e s..........................

10

4. So parsau roc.mr.u.T t%a TeLecoa II r

INTRODUCTION SAIC has reviewed the,rrerg'ssubmittals prepared in response to te 83-28, item 1.2 " Post-Trip Review:

Data and Information Capability".

The submittals (see references) contained sufficient information to determine that the data and capabilities at this plant are acceptable in the following areas.

The sequence-of-events recorder (s) performance charac-e teristics, The time history recorder (s) performance characterfs-o tics.

The output format of the recorded data.

e However, the data and information capabilities, as described in the submittal, either fail to meet the review criteria or provide insufftetent information to allow determination of the adequacy of the data and information capabilities in the following areas.

The parameters monitored by both the sequence-of-events e

and time history recorders.

The long-term data retention, record keeping, capa-e bility.

l 1

1

===1.

Background===

On February 25, 1984, both of the scram circuit breakers at Unit 1 of

~

the Salem Nuclear Power Plant failed to open upon an automatic reactor trip signal from the reactor protection system.

This incident occurred during the plant startup and the reactor was tripped manually by the operator about 30 seconds after the initiation of the automatic trip signal.

The failure of the circuit breakers has been determined to be related to the sticking of the under voltage trip attachment.

Prior to this incident; on February 22, 1983; at Unit 1 of the Salem Nuclear Power Plant an automatic trip signal was generated based on steam generator low-low level during plant startup.

In this case the reactor was tripped manually by the operator almost coinci-4 dentally with the automatic trip. At that time, because the utility did not have a requirement for the systematic evaluation of the reactor trip, no investigation was performed to determine whether the reactor was tripped automatically as expected or manually. The utilities' written procedures required only that the cause of the trip be determined and identified the responsible personnel that could authorize a restart if the cause of the trip is known.

Following the second trip which clearly indicated the problem with the trip breakers, the question was raised on whether the circuit breakers had functioned properly during the earlier incident.

The most useful source of information in this case, namely the sequence of events printout which would have indicated whether the reactor was tripped automatically or manually during the February 22 incident, was not retained after the incident.

Thus, no ju.dgment on the proper functioning of the trip system during the earlier incident could be made.

Following these incidents; on February 28, 1983; the NRC Executive Director for Operations (EDO), directed the staff to investigate and repo.rt on the generic implications of these occurrences at Unit 1 of the Salem Nuclear Power Plant.' The results of the staff's inquiry into the generic implications.of the Salem Unit incidents is reported in NUREG-1000, " Generic Implications of ATWS Events at the Sales Nuclear Power Plant."

Based on the j

results of this study, a set of required actions were developed and included in Generic Letter 83-28 which was issued on July 8,1983 and sent to all i

. licensees of operating reactors, appif cants for operating license, and i

construction permit holders. The required actions in this generic letter consist of four categories. These are:

(1) Post-Trip Review, (2) Equipment 2

mv-.e-,

e

.wu.

...,-,er.

eg.

y 3

=. _, _,3y y.- - -

-m,

.w-,-my..p 3

,yys-g

-y.-

.g p


v-vw

---y---- - - -.mw

l Classification and Vender Interface. (3) Post Maintenance Testing, and (4)

Reactor Trip System Reliability Improvements.

The first required action of the generic letter, Post-Trip Reviiw, is the subject of this TER and consists of action item 1.1 " Program Description and Procedure" and action item 1.2 " Data and Information Capcbility." In the next section the review criteria used to assess the adequacy of the utilities' responses to the requirements of action item 1.2 will be discussed.

2.

- Review Criteria The intent of the Post Trip Review requirements of Generic Letter 83-28 is to ensure that the licensee has adequate procedures and data and information sources to understand the causbnd progression of a reactor trip. This understanding should go beyond a# simple identification of the

.o course of the event.

It should include the capability to determine the root cause of the reactor trip and to determine whether safety limits have been exceeded and if so to what extent. Sufficient information about the reactor trip event should be available so that a decision on the acceptability of a

~

reactor restart can be made.

The following are the review criteria developed for the requirements of Generic Letter 83-28, action item 1.2:

The equipment that provides the digital sequence of events (50E) record and the analog time history records of an unscheduled shutdown should pro-

' ' ~

vide a reliable source of the necessary information to be used in the post trip review.

Each plant variable which is necessary to determine the cause(s) and progression of the event (s) following a plant trip should be monitored by at least one recorder Quch as a sequence-of-events recorder or a plant process computer for digital parameters; and strip charts, a plant process computer or analog recorder for analog (time history) variables).

Each device used to record an analog or digital plant variable should be described in sufficient detail so that a determination can be made as to whether the following performance characteristics are met:

3

,-,.r

....-~.,. _. - _ - _ _

._.m..

._._,-...,_,,,,.,,-....-,,.__.,._,_,m,.

.--m-

\\

Each sequence-of-events recorder should be capable of detecting e

i and recording the sequence of events with a sufficient time discrimination capability to ensure that the time responses..asso-clated with each monitored safety-related system can be ascer-i tained, and that a determination can be made as to whether the time response is within acceptable Ifmits based on

- FSAR Chapter 15 Accident Analyses.

The I

recommended guideline for the SOE time discrimination is approxi-mately 100 usec.

If current SOE recorders do not have this time

{

discrimination capability the licensee or applicant should show that the current time discrimination capability is sufficient.for an adequate reconstruction of the course of the reactor trip.

As a minimum this should include the ability to adequately recon-

~

struct the accident scenarios presented in Chapter 15 of the plant FSAR.

Each analog time history data recorder should have a sample inter-e

)

val small enough so that the incident can be accurately reconstructed following a reactor trip.

As a minimum., the licensee or applicant should be able to reconstruct the course of i

the accident sequences evaluated in the accident analysis of the plant FSAR (Chapter 15). The recommended guideline for the sample interval is 10 sec.

If the time history equipment does not meet this guideline, the licensee or applicant should show that the current time history capability is sufficient to accurately recon-

~

struct the accident sequences presented in Chapter 15 of the FSAR.

To support the post trip analysis of the cause of the trip and the o

~

proper functioning of involved safety related equipment, each analog time history data recorder should be capable of upda~ ting and retaining information from approximately five minutes prior to the trip until at least ten minutes after the trip.

The information gathered by the sequence-of-events and time o

history data collectors should be stored in a manner that will allow for retrieval and analysis.

The data may be retained

~ in either hardcopy (computer printout, strip chart output, etc.)

or in an accessible memory (magnetic disc or tape).

This i

4 1

. r.

r

__.,.. _.,.. _.. ~ ~.. _,

_.____y_,..

j) information should be presented in a readable and meaningful

[

format, taking into consideration good human factors practices (such as those outlined in NUREG-0700).

t All equipment used to record sequence of events and time history e

information should be powered from a reliable and non-interruptible power source. The power source used need not be safety related.

i The sequence of events and time history recording equipment should

)

monitor sufficient digital and analog parameters, respectively, to assure that the course of the reactor trip can be reconstructed.

The parameters monitored should provide sufficient information to determine the root cause of the reactor trip, the progression of the reactor trip, and the response of the plant parameters and systems to the reactor trip.

Specifically, all input parameters associated with reactor trips, safety injections and other 3

safety-related systems as well as output parameters sufficient to record the proper functioning of these systems should be recorded for use in the post trip review.

The parameters deemed necessary, as a minimum, to perform a j

post-trip review (one that would determine if the plant remained within its design envelope) are presented on Tables 1.2-1 and 1.2-2.

If the appli-cants' or Itcensees' SOE recorders and time history recorders do not monitor all of the parameters suggested in these tables the appitcant or Itcensee i

should show that the existing set of monitored parameters are sufficient to 4

establish that the plant remained within the design envelope for the appro-priate accident conditions; such as those analyzed in Chapter 15 of the plant Safety Analysis Report.

Information gathered during the post trip review is required input for future post trip reviews.

Data from all unscheduled shutdowns provides a valuable reference source for the determination of the acceptability of the plant vital parameter and equipment response to future unscheduled shut-downs.

It is therefore N that information gathered during all post g

tr.ip reviews be maintained in an accessible manner for the 1tfe of the plant.

4 5

J v

e--

a,

,+.-..-n.,.

, -..,,. ~. - -..... -... ~.., - -

Table 1.2-1.

PWR Parameter List

~

SOE Time History

' Recorder Recorder Parameter / Signal (il x Reactor Trip 3

i (1) x Safety Injection x

Containment Isolation (1) x Turbine Trip x

Control Rod Position (1) x x

Neutron Flux, Power x

K Containment Pressure (2)

Containment Radiation x

Containment Sump Level (1) x x

Primary System Pressure (1)x x

Primary System Temperature (1) x Pressurizer Level (1) x Reactor Coolant Pump Status (1) x x

Primary System Flow (3)

Safety Inj.; Flow. Pump / Valve Status x

MSIV Position x

x Steam Generator Pressure (1) x x

Steam Generator Level (1) x x

Feedwater Flow (1) x x

Steam' Flow (3)

Auxiliary Feedwater System; Flow, Pump /Value Status AC and DC System Status (Bus Voltage) x Diesel Generator Status (Start /Stop, x

On/Off) x PORY Position (1.): Trip parameters

.(2): Parameter may be monitored by either an SOE or time history recorder.

.(3): Acceptable recorder options are: (a) system flow recorded on an SOE recorder, (b) system flow recorded on a time history recorder, or (c) equipment status recorded on an SOE recorder.

6

Table 1.2-2.

BWR Parameter List SOE Time History Recorder Recorder Parameter / Signal

.l x

Reactor Trip x

Safety Injection x

Containment Isolation x

Turbine Trip x

Control Rod Position x (1) x Neutron Flux, Power x (1)

Main Steam Radiation

~

'(2)

Containment (DryWell) Radiation x (1) x Drywell Pressure (Containment Pressure)

(2)

Suppression Pool Temperature x (1) x Primary System Pressure x(1) x Primary System Level x

MSIV Position x (1)

Turbine Stop Valve / Control Valve Position x

Turbine Bypass Valve Position x

Feedwater Flow x-Steam Flow (3)

Recirculation; Flow. Pump Status x(1)

Scram Discharge Level x (1)

Condenser Vacuum AC and DC System Status (Bus Voltage) x (3)(4)

Safety Injection; Flow. Pump / Valve Status x

Diesel Generator Status (On/Off, Start /Stop)

(1): Trip parameters.

(2): Parameter may be recorded by either an SOE or time history recorder.

(3): Acceptable recorder options are: (a) system flow recorded on an SOE recorder (b) system flow recorded on a time history recorder, or (c) equipment status recorded on an SOE recorder.

(4): Includes recording of parameters for all applicable systems from the following: HPCI, LPCI, LPCS, IC, RCIC.

7

3.

Evaluation M

The parameters identified in part 2 of this report as a part of the review criteria are those deemed gMo perform an adequate post-trip review.

The recording of these parameters on equipment that meets the guidelines of the review criteria will result in a source of information that can be used to determine the cause of the reactor trip and the plant response to the trip, including the responses of important plant systems.

The parameters identified in this submittal as being recorded by the

~

sequence of events and time history recorders do not correspond to the parameters specified in part 2 of thi:: report.

~

The information provided in the submittal indicates that the equipment used to monitor the digital and analog parameters meets the minimal requirements set forth in part 2 of this report. The sequence of events and analog time history recorders are powered from a non-interruptable power supply. The monitoring characteristics are all within the guidelines of the review criteria.

The data and information recorded for use in the post-trip review should be output in a format that allows for ease of identification and use of the data to meet the review criterion that calls for information in a readable and meaningful format. The information contained in this submittal indicates that this 6 is met.

M

_A The data and information used during a post-trip revi tw should be retained as part of the plant files. This information could prove useful during future ' post-trip reviews. Therefore one 6' presented in part 2 of this report is that information used during a post-trip review be maintained in an accessible manner for the life of the plant.

Information contained within this submittal does not indicate that this criterion will be met.

l 8

1

-- l

4.

Conclusion The information supplied in response to Generic Letter 83-28 indicates that the current post-trip review data and information capabilities are adequate in the following areas:

1.

The SOE recorders meet the minimum performance characteristics.

2.

The time history recorders meet the minimum performance character-istics.

The recorded data is output in a readable and meaningful fomt.

~

3 The information supplied in response to Generic Letter 83-28 does not indicate that the post-trip review data and information capabilities are adequate in the following areas:

1.

As described in the submittal, sufficient analog and digital parameters are not recorded for use in the post-trip review.

2.

The data retention procedures, as desrribed in the submittal, may not ensure that the information recorded for the post-trip review is maintained in an accessible manner for the, life of the plant.

Ma rk It is possible that the current data and information capabilbes at this nuclear power plant are adequate to meet the intent of these 6, P

'~~

but were not completely described.

Under these circumstances, the licensee should provide an updated, more complete, description to show in more detail the data and information capabilities at this nuclear power plant. If the information provided accurately represents all current data and information capabilties, then the licensee should either show that the current post trip review data and information capabilities are adequate to meet the intent of the criteria in part 2 of this report, or detail future modifications that would enable the licensee to meet the intent of the evaluation criteria.

9

j i

REFERENCES NRC Generic Letter 83-28.

Letter to all licensees of operating reactors, applicants for operating license, and holders of construction permits regarding Required Actions Based on Generic Implications of i'

Salem ATWS Events." July 8, 1983.

NUREG-1000. Generic Implications of ATWS Events at the Salem Nuclear Power Pht April 1983.

Letter from W.C. Jones Omaha Public Power District, to D.G. Eisenhut, NRC, dated November 4,1983, Accession Number 8311080428 in response to

~

Generic Letter 83-28 of July 8,1983, with attachment.

Omaha Public Power District Response to Generic Letter 83-28 dated November 4, 1983.

Letter from R.L. Andrews. Omaha Public Power District, to J.R. Miller, NRC, dated November 16, 1984 Accession Number 8411260365 providing additional information in response to Generic Letter 83-28, with e

attachments.

4 e e ee 1

10 9

+

,,----=--------,.--.w.v--m,,,.e,.,

,,p,_

y-

--%,.g.m-,--,-,g.-,%-.-

,y-

+-

.w,-

%y

,9.,,..

7,--,. -,-s&

e---,m--

+,,

v>--

SCff*C2M> peremsser % wou Fort Calhoun

~

1.

Parameters recorded: Unsatisfactory See attached table for discrepancies.

2.

SOE recorder' performance characteristics:

Satisfactory Plant process computer:

interruptible power supply 16.6 msec time discrimination with a non-

3.. Time history recorders performance characteristics:Satisfactory Strip charts:

monitoring of parameters meets intent of perfor tics requirements 4.

Data output format: Satisfactory 1

SOE data output includes time event descriptor and sensor chann Analog data output in strip chart forms meets requirements 5.

Data retention capability: Unsatisfactory Data is retained but for an unspecified period of time.

0 4

\\\\

/) M M PWR Parameters for Post Trip Review (circled parameters are not recorded)

SOE Time History

~

Recorder Recorder

_ Parameter / Signal

6) x Reactor Trip (1) x Safety Injection x

Containment Isolation (1) x Turbine Trip x

Control Rod Position (1) x Neutron Flux, Power x

K Containment Pressure Containment Radiation x

Containment Sump Level (1)(3)

Primary System Pressure (Vessel Pressure, (1)x Pressurizer Pressure) x Primary System Temperature (1)x Pressurtzer Level (1)x Reactor Coolant Pump Status (1) x Primary System Flow 8x 4

Safety Inj.; Flow. Pump / Valve Status MSIV Position x

x Steam Generator Pressure (1)

Steam Generator Level (1)

Feedwater Flow (1) x Steam Flow Auxiliary Feedwater System; Flow.

Pump /Value Status 8x x

AC and DC System Status Diesel Generator Status x

POW Position (1): Trip parameters; pressurizer or primary pressure is a trip parameter (depending on plant).

(2): Acceptable recorder options are: Parameter may be monitored by eith (3):

(a) reactor vessel pressure recorded on both an SOE and time history recorder, or (b) pressurizer pressure recorded on both an SOE and time history recorder.

(4): Acceptable recorder options are: (a) system flow recorded on an SOE equipment status recorded on an SOE recorder. recorder, (b) syst Ib

Ft. Calhoun Harry H. Voigt, Esquire LeBoeuf, Lamb, Leiby & MacRae 1333 New Hampshire Avenue, NW Washington, DC 20036 Mr. Jack Jensen, Chairman Washington County Board of Supervisors Blair, Nebraska 68023 Metropolitan Planning Agency ATTN: Dagnia Prieditis 7000 West Center Road Omaha, Nebraska 68107 Mr. Larry Yandell U.S. NRC Resident Inspector Post Office Box 309 Fort Calhoun, Nebraska 68023 Mr. Charles B. Brinkman, Manager Washington Nuclear Operations C-E Power Systems 7910 Woodmont Avenue Bethesda, Maryland 20814 Regional Administrator USNRC, Region IV Office of Executive Director for Operations 611 Ryan Plaza Drive, Suite 1000 Arlington, Texas 76011 P