Text
-.
f.
O i
CONSUMERS POWER COMPAWT DOCKET No. 50-155 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 8 License 50 DPR-6 1.
h Atomic Energy Commission (the e - fasion) has fond thats A.
h filings by the Consumers Four Company (the licensee) dtted June 29, 1973, and February 7,1974, cociply with the atmJctrds and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regnistions set forth in 10 CFR Chapter I; B.
The facility will operate in conformity with the application, the provisions of the Act, and the rules and rigulations of the Commission; C.
hre is reasonable assurance (i) that the er,tivities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be j
conducted in complisace with the Commission's regulations; l
l D.
N issuance of this amendment will not be in1= teal to the common defense and security or to the health and safety of the public; and E.
bre vers no requests for a hearing or petition for leave to intervene filed following notice of the proposed action.
2.
Accordingly, the license is amended by a change to the Technical Specifications as indicated ife the attachment to this license amendernat and paragraph 3.B cf Facility License No. DPR-6 is hereby amended to read as follows:
EIv) fk orrice >
suuwt >
OnE>
ror. Atc-3ie inev. s.ss3 ncx ono
.-i._.i i
.n ew
-,-.m-.
-r. yes.
r-
,c
...r,,.
y#.-,-e,m.,v
..e_.,m-.,
.....,i-+.,..w
.--1w,.-,%.
.w w -
w-+ w i
t 2
"B.
Technical Specifications The Technical Specifications contained in Appendix A, as revised, are hereby incorporated in the license.
The licensee shall operate the facility in accordance with the Technical Specifications, as revised by issued changes thereto through Change No. 45."
3.
This license amendment is effective as of the date of its issuance.
FOR THE ATONIC EIERGY f;0MMISSIDE Original signed by:
Earl R. Goller Karl 1. Coller, Assistant Director for Operating Reactors Directorate of Licensing Attachment Change No. 45 to the Technical Specifications Date of Issuancea g,,
-g, y omet >
suawe >
our>
Form AIC-St B (Rev. 9-$3) AECM 0240 e4Ho-s14aa 64H7s 4
- eg
,. ~ _.,
-_,,_._,,.,,,..m
ATTACIDENT A TO LICENSE AMLMDMDrf NO. 8_
CHANGE No. 45 TO THE TECHNICAI,SPECIFICATIONg LICENSE NO. DPR-4 CONSUMERS POWER COHPANY DOCKET NO. 50-155 1.
Add a new item 3 to Paragraph 4.1.2(c) to read as follows:
"3.
The high energy line sections identified in Table 9-3b shall be maintained free of visually observable through-wall leaks.
(a) If a leak is detected by the surveillance program of 4.6 k., efforts to idantify the source of the leak shall be started immediately.
(b) If the source of leakage cannot be identified within eight hours of detection or if the leak is found to be from a break in the sections identified in Table 9-3b, the reactor shall be in a cold abutdown within 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br />."
2.
Change item 9.1 to read as follows:
9.1 APPLICABILITY Applies to in-service structural surveillance of primary system components and high energy piping (outside containment).
3.
Add the following item a to Paragraph 9.3 "e.
The structural integrity of the high energy line sections identified in Table 9.3(b) shall be maintained at the level required by Section XI of the ASME Boiler and Pressure Vessel i
u:6, 1974, Article IWB 3000."
4.
Add to 9.4 Basis the following paragraphs Intensive analysis and review has shown that there are distinct areas of concern where failure of high energy piping systems could preclude the possibility of a safe cold shutdown using safeguards equipment.
t This conclusion is based on utilising the basic AEC high energy line pipe break criteria. In the interim period, while the plant is operating, OFTICE >
SURNAME >
DATE >
form AEC-Sts (Rev.9 53) AFCM 0240
.ee
.es-se-si4es-s.s.-s7s
--,m.e
,.---...,.r.i-c.. -.
.,..,-.~..,-..-,..-...--x-
-.c--_w...
,-*w v
e 2
it therefore becomes necessary to apply additional naasures to enhance the detection of piping system weaknesses in order to mitigate the effects of a pipe rupture. The inservice examination and the frequency of inspection will provide a means for titxily dstection and need only be in effect until required modifications are complete.
5.
Add the attached Table 9.3(b) to the end of Section 9.
i I
omcc >
l su%we>
cart >
Form AEC-SIS (Rev. 9 53) AECM 0240 ees--ts-sitas-44s-47s g 'e ag
.,.se e.v.
+<n e,
-.m-
~
fr 1
Table 9.3(b) 2 i
I Initial Periodic f
Item No.
High Energy Area Examination Method Leakage Check **.
Frequency 1
Main steam line from Volumetric visual Monthly l
containment-penetration to turbine stop valve f.
2 Feedwater line from Volumetric Visual.
Monthly f
containment penetration to place of exit from main steam tunnel 4
L i
The areas to be examined shall include the longitudinal and circumferential welds and base metal
~
I, for one wall thickness beyond the edge of the welds. The : inspections. shall be completed within 6
3 a6nths of issuance of this change.