Amendment No. 83 License No. NPF-76 1.
The Nuclear Regulatory Comission (the Comission) has found that:
i A.
The application for amendment by Houston Lighting & Power Company
- l (HL&P) acting on behalf of itself and for the City Public Service i
Board of San Antonio (CPS), Central Power and Light Company (CPL),
and City of Austin, Texas (C0A) (the licensees), dated January 22, 1996, as supplemented April 4 and May 2, 1996, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Comission's rules and regulations set l
forth in 10 CFR Chapter I; B.
The facility will operate in conformity with the application, as l
amended, the provisions of the Act, and the rules and regulations of the Comission; C.
There is reasonable assurance:
(1) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be l
conducted in compliance with the Comission's regulationr; D.
The issuance of this license amendment will not be inimical to the common defense and security or to the health and safety of the l
public; and E.
The issuance of this amendment is in accordance with 10 CFR Part 51 of the Comission's regulations and all applicable requirements have been satisfied.
i
- Houston Lighting & Power Company is authorized to act for the City Public Service Board of San Antonio, Central Power end Light Company and City of Austin, Texas and has exclusive responsibility and control over the physical construction, operation and maintenance of the facility.
9605240181 960522 PDR ADOCK 05000498 P
PDR a
w 2.
Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment and Paragraph 2.C.(2) of Facility Operating License No. NPF-76 is hereby amended to read as follows:
2.
Technical Specifications The Technical Specifications contained in Appendix A, as revised l
through Amendment No. 83, and the Environmental Protection Plan l
contained in Appendix B, are hereby incorporated in the license.
The licensee shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.
3.
The license amendment is effective as of its date of issuance with full implementation within 10 days.
FOR THE NUCLEAR REGULATORY C0PtilSSION V
l Thomas W. Alexion, Project Manager Project Directorate IV-1 Division of Reactor Projects III/IV Office of Nuclear Reactor Regulation
Attachment:
Changes to the Technical Specifications Date of Issuance:
May 22, 1996 i
at;g
.t ATTACHMENT TO LICENSE AMENDMENT NO. 83 FACILITY OPERATING LICENSE NO. NPF-76 DOCKET NO. 50-498 Replace the following pages of the Appendix A Technical Specifications with the attached pages. The revised pages are identified by Amendment number and contain marginal lines indicating the areas of change. The corresponding overleaf pages are also provided to maintain document completenest.
REMOVE INSERT 3/4 4-13 3/4 4-13 3/4 4-13a 3/4 4-15 3/4 4-15 3/4 4-16 3/4 4-16 3/4 4-16a 3/4 4-16b l
l 3/4 4-20 3/4 4-20 B 3/4 4-2a B 3/4 4-2a l
B 3/4 4-3 B 3/4 4-3 B 3/4 4-3a l
l B 3/4 4-4 B 3/4 4-4 i
(
l
\\
f
.~...
ql t
4 STEAM GENERATORS SURVEILLANCE REQUIREMENTS (Continued) 3)
A tube inspection (pursuant to Specification 4.4.5.4a.8) shall be perfomed on each selected tube.
If any selected tube does not pemit the passage of the eddy current probe for a tube inspection, this shall be recorded and an adjacent tube shall l
be selected and subjected to a tube inspection, j
l 4)
Indications left in service as a result of application of the l
tube support plate voltage-based repair criteria shall be inspected by sobbin coil probe during all future refueling outages.
I c.
The tubes selected as the second and third samples (if required by i
Table 4.4-2) during each inservice inspection may be subjected to a partial tube inspection provided:
1)
The tubes selected for these samples include the tubes from those areas cf the tube sheet array where tubes with 1
imperfections were previously found, and l
l 2)
The inspections include those portions of the tubes where i
l imperfections were previously found.
d.
For Unit 1, any tube allowed to remain in service per Acceptance Criterion 10 (of Technical Specification 4.4.5.4) shall be inspected
)
via the rotating pancake coil (RPC) eddy current method over the F*
l distance.
Such tubes are exempt from eddy current inspection over the portion of the tube below the F* distance which is not structurally relevant.
I For Unit 1, implementation of the steam generator tube / tube support e.
plate repair criteria requires a 100-percent bobbin coil inspection for hot-leg and cold leg tube support plate intersections down to the lowest cold-leg tube support plate with known outside diameter stress corrosion cracking (00 SCC) indications. The determination of j
the lowest cold-leg tube support plate intersections having 00 SCC l
indications shall be based on the performance of at least a 20-percent random sampling of tubes inspected over their full length.
The results of each sample inspection shall be classified into one of the following three categories.
Cateoorv Inspection Results C-1 Less than 5% of the total tubes inspected are i
degraded tubes and none of the inspected tubes are i
defective.
i i
SOUTH TEXAS - UNITS 1 & 2 3/4 4-13 Unit 1 - Amendment No. 84, s3
.tgj 3
REACTOR COOLANT SYSTEM STEAM GENERATORS SURVEILLANCE REOUIREMENTS (Continued)
C-2 One or more tubes, but not more than 1% of the total tubes inspected are defective, or between 5% and 10%
of the total tubes inspected are degraded tubes.
C-3 More than 10% of the total tubes inspected sre degraded tubes or more than 1% of the inspected tubes are defective.
Note:
In all inspections, previously degraded tubes must exhibit significant (greater than 10%) further wall penetrations to be included in the above percentage calculations.
SOUTH TEXAS - UNITS 1 & 2 3/4 4-13a Unit 1 - Amendment No. O
REACTOR COOLANT SYSTEM STEAM GENERATORS SURVEILLANCE REQUIREMENTS (Continued) 4.4.5.3 Inspection Frequencies - The above required inservice inspections of steam generator tubes shall be performed at. the following frequencies:
a.
The first inservice inspection shall be performed after 6 Effective Full Power Months but within 24 calendar months of initial criticality.
Subsequent inservice inspections shall be performed at intervals of not less than 12 nor more than 24 calendar months after the previous inspection.
If two consecutive inspections, not including the preser-vice inspection, result in all inspection results falling into the C-1 1
category or if two consecutive inspections demonstrate that previously observed degradation has not continued and no additional degradation has occurred, the inspection interval aay be extended to a maximum of once per 40 months; b.
If the results of the inservice inspection of a steam generator conducted in accordance with Table 4.4-2 at 40-month intervals fall in Category C-3, the inspection frequency shall be increased to at least once per 20 months.
The increase in inspection frequency shall apply until the subsequent inspections satisfy the criteria of Specification 4.4.5.3a.; the interval may then be extended to a maximum of once per 40 months; and c.
Additional, unscheduled inservice inspections shall be performed on each steam generator in accordance with the first sample inspection specified in Table 4.4-2 during the shutdown subsequent to any of the following conditions:
1)
Primary-to-secondary tube leaks (not including leaks originating from tube-to-tube sheet welds) in excess of the limits of Specification 3.4.6.2, or i
2)
A seismic occurrence greater than the Operating Basis Earthquake, or 3)
A loss-of-coolant accident requiring actuation of the Engineered Safety Features, or 4)
A main steam line or feedwater line break.
i I
SOUTH TEXAS - UNITS 1 & 2 3/4 4-14
\\
j SURVEILLANCE REQUIREMENTS (Continued) 1 2
4.4.5.4 Accentance Criteria a.
As used in this specification:
l j
1)
Imperfection means an exception to the dimensions, finish, or contour of a tube from that required by fabrication drawings or i
specifications. Eddy-current testing indications below 20% of l
the nominal tube wall thickness, if detectable, may be l
considered as imperfections; l
2)
Dearadation means a service-induced cracking,
wastage, wear, or i
general corrosion occurring on either inside or outside of a tube; s
3)
Dearaded Tube means a tube containing imperfections greitsi than or equal to 20% of the nominal wall thickness caused by degradation; 4)
% Dearadation means the percentage of the tube wall thickness affected or removed by degredation; 5)
Defect means an imperfection of such severity that it exceeds the plugging limit. A tube containing a defect is defective; 6)
Pluaaina Limit means the imperfection depth at or beyond which the tube shall be removed from service and is equal to 40% of the nominal tube wall thickness. For Unit 1, this definition does not apply to tube support plate intersections for which the voltage-based repair criteria are being applied. Refer to 4.4.5.4.a.11 for the repair limit applicable to these intersections.
7)
Unserviceable describes the condition of a tube if it leaks or contains a defect large enough to affect its structural integrity in the event of an Operating Basis Earthquake, a loss-of-coolant accident, or a steam line or feedwater line break as specified in Specification 4.4.5.3c., above; 8)
Tube Insoection means an inspection of the steam generator tube from the point of entry (hot leg side) completely around the U-bend to the top support of the cold leg; and 9)
Preservice Insoection means an inspection of the full length of each tube in each steam generator perfonned by eddy current techniques prior to service to' establish a baseline condition of the tubing. This inspection shall be performed prior to initial POWER OPERATION using the equipment and techniques expected to be used during subsequent inservice inspections.
SOUTH TEXAS - UNITS 1 & 2 3/4 4-15 Unit 1 - Amendment No. 83
T I
REACTOR COOLANT SYSTEM STEAM GENERATORS SURVEILLANCE REQUIREMENTS (Continued)
(10) F* criteria IFor Unit 1 on1v1 Tube degradation below a specified distance from the hard roll contact point at or near the top-of-tubesheet (the F* distance) can be excluded from consideration to the acceptance criteria stated in this section (i.e., plugging of such tubes is not required). The methodology for determination for the F* distance as well as the list of tubes to which the F* criteria is not applicable is described in detail in Topical Report - BAW 10203P, Revision 0.
(11) For Unit 1, Tube Suonort Plate Pluaaina Limit is used for the disposition of an alloy 600 steam generator tube for continued service that is experiencing predominately axially oriented outside diameter stress corrosion cracking confined within the thickness of the tube support plates. At tube support plate intersections, the plugging (repair) limit is based on maintaining steam generator tube serviceability as described below:
a)
Steam generator tubes, whose degradation is attributed to outside diameter stress corre: ion cracking within the bounds of the tube support plate with bobbin voltage less than or equal to the lower voltage repair limit (Note 1),
will be allowed to remain in service.
b)
Steam generator tubes, whose degradation is attributed to outside diameter stress corrosion cracking within the bounds of the tube support plate with a bobbin voltage greater than the lower voltage repair limit (Note 1), will be repaired or plugged, except as noted in 4.4.5.4.a.ll.c below.
c)
Steam generator tubes, with indications of potential degradation attributed to outside diameter stress corrosion cracking within the bounds of the tube support plate with a bobbin voltage greater than the lower voltage repair limit (Note 1) but less than or equal to the upper repair voltage limit (Note 2), may remain in service if a rotating pancake coil inspection does not detect degradation. Steam generator tubes, with indications outside diameter stress corrosion cracking degradation with bobbin voltage greater than the upper voltage repair limit (Note 2) will be plugged or repaired.
SOUTH TEXAS - UNITS 1 & 2 3/4 4-16 Unit 1 - Amendment No. 80, 83
STEAM GENERATORS SURVEILLANCE REQUIREMENTS (Continued) d)
Certain intersections as identified in Framatome l
Technologies, Inc. Topical Report BAW-10204P, " South Texas l
Project Tube Repair Criteria for ODSCC At Tube Support Plates" will be excluded from application of the l
l voltage-based repair criteria as it is determined that these intersections may collapse or deform following a postulated LOCA + SSE event.
e)
If an unscheduled mid-cycle inspection is performed, the mid-cycle repair limits apply instead of the limits identified in 4.4.5.4.a.11.a. 4.4.5.4.a.ll.b, and 4.4.5.4.a.ll.c.
The mid-cycle repair limits will be determined from the equations for mid-cycle repair limits of NRC Generic Letter 95-05, Attachment 2, page 3 of 7.
Implementation of these mid-cycle repair limits should follow the same approach as in TS 4.4.5.4.a.11.a, 4.4.5.4.a.11.b, and 4.4.5.4.a.11.c.
Note 1:
The lower voltage repair limit is 1.0 volt for 3/4-inch diameter tubing or 2.0 volts for 7/8-inch diameter tubing.
The upper voltage repair limit (V is calculated according to the methodology in Generic Letter 95 $)as supplemented. V, may Note 2:
differ at the TSPs and flow distribution baffle.
b.
The steam generator shall be determined OPERABLE after completing the corresponding actions (plug all tubes exceeding the plugging limit and all tubes containing through-wall cracks) required by Table 4.4-2.
l 4.4.5.5 Reports a.
Within 15 days following the completion of each inservice inspection of steam genera br tubes, the number of tubes plugged in each steam generator shall be reported to the Commission in a Special Report pursuant to Specification 6.9.2; f
b.
The complete results of the steam generator tube inservice i
inspection shall be submitted to the Commission in a Special Report pursuant to Specification 6.9.2 within 12 months following the completion of the inspection. This Special Report shall include:
1)
Number and extent of tubes inspected, 2)
Location and percent of wall-thickness penetration for each
]
indication of an imperfection, and 3)
Identification of tubes plugged.
SOUTH TEXAS - UNITS 1 & 2 3/4 4-16a Unit 1 - Amendment No. 83
pq REACTOR COOLANT SYSTEM STEAM GENERATORS SURVEILLANCE REQUIREMENTS (Continued) c.
Results of steam generator tube inspections which fall into Category C-3 shall be reported in a Special Report to the Commission pursuant to Specification 6.9.2 within 30 days and prior to resumption of plant operation. This report shall provide a description of investigations conducted to determine cause of the tube degradation and corrective measures taken to prevent recurrence.
d.
For Unit 1, implementation of the voltage-based repair criteria to tube support plate intersections, notify the Staff prior to returning the steam generators to service should any of the fc110 wing conditions arise:
t 1.
If estimated leakage based on the projected end-of-cycle (or if not practical, using the actual measured end-of-cycle) voltage i
distribution exceeds the leak limit (determined from the licensing basis dose calculation for the postulated main steam line break) for the next operating cycle.
2.
If circumferential crack-like indications are detected at the i
tube support plate intersections.
3.
If indications are identified that extend beyond the confines of the tube support plate.
4.
If indications are identified at the tube support plate elevations that are attributable to primary water stress corrosion cracking.
5.
If the calculated conditional burst probability based on the measured end-of-cycle) voltage distribution exceeds 1 x 10',a1 projected end-of-cycle (or if not practical, using the actu notify the NRC and provide an assessment of the safety significance of the occurrence.
i i
SOUTH TEXAS - UNITS 1 & 2 3/4 4-16b Unit 1 - Amendment No. "
q:
REACTOR COOLANT SYSTEM 3/4.4.6 REACTOR COOLANT SYSTEM LEAKAGE LEAKAGE DETECTION SYSTEMS LIMITING CONDITION FOR OPERATION 3.4.6.1 The following Reactor Coolant System Leakage Detection Systems shall be OPERABLE:
The Containment Atmosphere Gaseous Radioactivity Monitoring System, a.
b.
The Containment Normal Sump Level and Flow Monitoring System, and The Containment Atmosphere Particulate Radioactivity Monitoring c.
System.
APPLICABILITY:
MODES 1, 2, 3, and 4.
ACTION:
With a. or c. of the above required Leakage Detection Systems in-a.
operable, operation may continue for up to 30 days provided grab samples of the containment atmosphere are obtained and analyzed for gaseous and particulate radioactivity at least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> when the required Gaseous or Particulate Radioactive Monitoring System is inoperable; otherwise, be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />, b.
With b. of the above required Leakage Detection Systems inoperable, be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUT-DOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.
With a. and c. of the above required Leakage Detection Systems c.
inoperable:
1)
Restore either Monitoring System (a. or c.) to OPERABLE status within 72 hou s and 2)
Obtain and analyze a grab sample of the containment atmosphere for gaseous and particulate radioactivity at least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />, and 3)
Perform a Reactor Coolant System water inventory balance at least once per 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />.
Otherwise, be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.
SURVEILLANCE REDUIREMENTS 4.4.6.1 The Leakage Detection Systems shall be demonstrated OPERABLE by:
Containment Atmosphere Gaseous and Particulate Monitoring Systems a.
performance of CHANNEL CHECK, CHANNEL CALIBRATION, and DIGITAL CHANNEL
{
OPERATIONAL TEST at the frequencies specified in Table 4.3-3, and b.
Containment Normal Sump Level and Flow Monitoring System performance of CHANNEL CALIBRATION at least once per 18 months.
f SOUTH TEXAS - UNITS 1 & 2 3/4 4-19 l
l lL.
_~
k REACTOR COOLANT SYSTEM OPERATIONAL LEAKAGE LIMITING CONDITION FOR OPERATION 3.4.6.2 Reactor Coolant System leakage shall be limited to:
a.
No PRESSURE BOUNDARY LEAKAGE, b.
I gpm UNIDENTIFIED LEAKAGE, c.
For Unit 1,150 gallons per day of primary-to-secondary leakage through any one steam generator, and for Unit 2, 1 gpa total reactor-to-secondary leakage through all steam generators and 500 gallons per day through any one steam generator, d.
10 gpm IDENTIFIED LEAKAGE from the Reactor Coolant System, and e.
0.5 gpm leakage per nominal inch of valve size up to a maximum of 5 gpm at a Reactor Coolant System pressure of 2235 1 20 psig from any Reactor Coolant System Pressure Isolation Valve specified in Table 3.4-1.*
APPLICABILITY: MODES 1, 2, 3, and 4.
ACTION:
a.
With any PRESSURE BOUNDARY LEAKAGE, be in at least HOT STANDBY within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />, b.
With any Reactor Coolant System leakage greater than any one of the above limits, excluding PRESSURE B0UNDARY LEAKAGE and leakage from Reactor Coolant System Pressure Isolation Valves, reduce the leakage rate to within limits within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.
c.
With any Reactor Coolant System Pressure Isolation Valve leakage greater than the above limit, isolate the high pressure portion of the affected system from the low pressure portion within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> by use of at least two closed manual or deactivated automatic valves, or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.
- Test pressures less than 2235 psig but greater than 150 psig are allowed.
Observed leakage shall be adjusted for the actual test pressure up to 2235 psig assuming the leakage to be directly proportional to pressure differential to the one-half power.
SOUTH TEXAS - UNITS 1 & 2 3/4 4-20 Unit 1 - Amendment No. 83
REACTOR COOLANT SYSTEM BASES RELIEF VALVES (Continued)
C.
Manual control of the block valve to:
(1) unblock an isolated PORV to allow it to be used for manual control of reactor coolant system pressure (Item A), and (2) isolate the PORV with excessive seat leakage (Item B).
D.
Manual control allows a block valve to isolate a stuck-open PORV.
3/4.4.5 STEAM GENERATORS The Surveillance Requirements for inspection of the steam generator tubes ensure that the structural integrity of this portion of the RCS will be maintained. The program for inservice inspection of steam generator tubes is based on a modification of Regulatory Guide 1.83, Revision 1.
Inservice inspection of steam generator tubing is essential in order to maintain surveillance of the conditions of the tubes in the event that there is evidence of mechanical damage or progressive degradation due to design, manufacturing errors, or inservice conditions that lead to corrosion.
Inservice inspection of steam generator tubing also provides a means of characterizing the nature and cause of any tube degradation so that corrective measures can be taken.
The plant is expected to be operated in a manner such that the secondary coolant will be maintained within those chemistry limits found to minimize l
corrosion of the steam generator tubes.
If the secondary coolant chemistry is not maintained within these limits, localized corrosion may likely result in stress corrosion cracking. The extent of cracking during plant operation would be limited by the 3.4.6.2.c limitation of steam generator tube leakage between the Reactor Coolant System and the Secondary Coolant System. Cracks having a primary-to-secondary leakage less than this limit during operation will have an adequate margin of safety to withstand the loads imposed during normal operation and by postulated accidents. Operating plants have demonstrated that primary-to-secondary leakage as low as 150 gallons per day per steam generator can readily be detected.
Leakage in excess of this limit will require plant shutdown and an unscheduled inspection, during which the leaking tubes will be located and plugged.
Wastage-type defects are unlikely with proper chemistry treatment of the secondary coolant. However, even if a defect should develop in service, it will be found during scheduled inservice steam generator tube examinations.
Except as discussed below, plugging will be required for all tubes with l
imperfections exceeding the plugging limit of 40% of the tube nominal wall thickness. Steam generator tube inspections of operating plants have demonstrated the capability to reliably detect degradation that has penetrated 20% of the original tube wall thickness.
Exclusion of certain areas of Unit I tubes from consideration has been analyzed using an F* criteria. The criteria allows service induced degradation deep within the tubesheet to remain in service. The analysis SOUTH TEXAS - UNITS 1 & 2 B 3/4 4-2a Unit 1 - Amendment No. 6b H. "
Unit 2 - Amendment No. 44
N REACTOR COOLANT SYSTEM BASES STEAM GENERATORS (Continued) methodolofly determines the length of sound fully rolled expanded tubing required ' n the uppemost area within the tubesheet to preserve needed structural margins for all service conditions. The remainder of the tube, below the F* distance, is considered not structurally relevant and is excluded from consideration to the customary plugging criteria of 40% throughwall.
The amount of primary to secondary leakage from tubes left in service by application of the F* criterion has been determined by verification testing.
This leakage has been considered in the calculation of postulated primary to secondary leakage under accident conditions. Primary to secondary leakage during accident conditions is limited such that the associated radiological consequences as a result of this leakage is less than the 10 CFR 100 limits.
For Unit 1, the voltage-based repair limits of SR 4.4.5 implement the guidance in GL 95-05 and are applicable only to Westinghouse-designed steam generators (SGs) with outside diameter stress corrosion cracking (00 SCC) located at the tube-to-tube support plate intersections. The voltage-based repair limits are not applicable to other forms of SG tube degradation nor are they applicable to 00 SCC that occurs at other locations within the SG.
Additionally, the repair criteria apply only to indications where the degradation mechanism is dominantly axial ODSCC with no significant cracks extending outside the thickness of the support plate.
Refer to GL 95-05 for additional description of the degradation morphology.
Implementation of SR 4.4.5 requires a derivation of the voltage structural limit from the burst versus voltage empirical correlation and then the subsequent derivation of the voltage repair limit from the structural limit (which is then implemented by this surveillance).
The voltage structural limit is the voltage from the burst pressure / bobbin voltage correlation, at the 95-percent prediction interval curve reduced to account for the lower 95/95-percent tolerance bound for tubing material properties at 650*F (i.e., the 95-percent LTL curve). The voltage structural limit must be adjusted downward to account for potential flaw growth during an operating interval and to account for NDE uncertainty.
The upper voltage repair limit; V is determined from the structural voltage limit by applying the fo1Dw,ing equation:
V
-V
-V,-V n
a where V represent the allowance for flaw growth between inspections ann V represeSn s the allowance for potential sources of error in the measuremem.a
- , i the bobbin coil voltage.
Further discussion of the assumptions necessary to determine the voltage repair limit are discussed in GL 95-05.
SOUTH TEXAS - UNITS 1 & 2 B 3/4 4-3 Unit 1 - Amendment No. E,83
REACTOR COOLANT SYSTEM BASES STEAM GENERATORS (Continued)
The mid-cycle equation in SR 4.4.5.4.a.11.e should only be used during unplanned inspections in which eddy current data is acquired for indications at the tube support plates.
SR 4.4.5.5 implements several reporting requirements recommended by GL 95-05 for situations which the NRC wants to be notified prior to returning the SGs to service. For the purpose of this reporting requirement, leakage and conditional burst probability can be calculated based on the as-found voltage distribution rather than the projected end-of-cycle voltage distribution (refer to GL g5-05 for more information) when it is not practical to complete these calculations using the projected E0C voltage distributions prior to returning the SGs to service. Note that if leakage and conditional burst probability were calculated using the E0C voltage distribution for the purposes of addressing the GL section 6.a.1 and 6.a.3 reporting criteria, then the results of the projected EOC voltage distribution should be provided per the GL section 6.b.(c) criteria.
Whenever the results of any steam generator tubing inservice inspection fall into Category C-3, these results will be promptly reported to the Connission in a Special Report pursuant to Specification 6.9.2 within 30 days and prior to resumption of plant operation. Such cases will be considered by the Commission on a case-by-case basis and may result in a requirement for analysis, laboratory examinations, tests, additional eddy-current inspection, and revision of the Technical Specifications, if necessary.
3/4.4.6 REACTOR COOLANT SYSTEM LEAKAGE 3/4.4.6.1 LEAKAGE DETECTION SYSTEMS The RCS Leakage Detection Systems required by this specification are provided to monitor and detect leakage from the reactor coolant pressure boundary. These Detection Systems are consistent with the reconnendations of Regulatory Guide 1.45, " Reactor Coolant Pressure Boundary Leakage Detection Systems," May 1973.
3/4.4.6.2 OPERATIONAL LEAKAGE PRESSURE BOUNDARY LEAKAGE of any magnitude is unacceptable since it may be indicative of an impending gross failure of the pressure boundary. Therefore, the presence of any PRESSURE BOUNDARY LEAKAGE requires the unit to be promptly placed in COLD SHUTDOWN.
Industry experience has shown that while a limited amount of leakage is expected from the RCS, the unidentified portion of this leakage can be reduced to a threshold value of less than 1 gpm. This threshold vale is sufficiently low to ensure early detection of additional leakage.
SOUTH TEXAS - UNITS 1 & 2 B 3/4 4-3a Unit 1 - Amendment No. 83
"4 REACTOR COOLANT SYSTEM BASES OPERATIONAL LEAKAGE (Continued)
For Unit 1, the leakage limits incorporated into SR 4.4.6 are more restrictive than the standard operating leakage limits and are intended to provide an additional margin to accommodate a crack which might grow at a greater than expected rate or unexpectedly extend outside the thickness of the tube support plate. Hence, the reduced leakage limit, when combined with an effective leak rate monitoring program, provides additional assurance that should a significant leak be experienced in service, it will be detected, and the plant shut down in a timely manner.
For Unit 2, the total steam generator tube leakage limit of I gpm for all steam generators not isolated from the RCS ensures that the dosage contribution from the tube leakage will be limited to a small fraction of 10 CFR Part 100 dose guideline valves in the event of either a steam generator tube rupture or steam line break. The 1 gpm limit is consistent with the assumptions used in the analysis of these accidents. The 500 gpd leakage limit per steam generator ensures that steam generator tube integrity is maintained in the event of a main steam line rupture or under LOCA conditions.
The 10 gpm IDENTIFIED LEAKAGE limitation provides allowance for a limited amount of leakage from known sources whose presence will not interfere with the detection of UNIDENTIFIED LEAKAGE by the Leakage Detection Systems.
The specified allowed leakage from any RCS pressure isolation valve is sufficiently low to ensure early detection of possible in-series check valve failure.
It is apparent that when pressure isolation is provided by two in-series check valves and when failure of one valve in the pair can go undetected for a substantial length of time, verification of valve integrity is required. Since these valves are important in preventing overpressurization and rupture of the ECCS low pressure piping which could result in a LOCA that bypasses containment, these valves should be tested periodically to ensure low probability of gross failure.
The Surveillance Requirements for RCS pressure isolation valves provide added assurance of valve integrity thereby reducing the probability of gross valve failure and consequent intersystem LOCA.
Leakage from the RCS pressure isolation valve is IDENTIFIED LEAKAGE and will be considered as a portion of the allowed limit.
3/4.4.7 CHEMISTRY The limitations on Reactor Coolant System chemistry ensure that corrosion of the Reactor Coolant System is minimized and reduces the potential for Reactor Coolant System leakage or failure due to stress corrosion. Maintaining SOUTH TEXAS - UNITS 1 & 2 B 3/4 4-4 Unit 1 - Amendment No.
.