n 10CFR50, Appendix E VI.3.a 4

v PECO NUCLEAR nm %v a-v Nuclear Group hiadquarters A tlNIT Of PfCO TNacy 965 Chestertm k Boulevard Wayne, PA 19087-5691 March 26,1996 Docket No. 50452 License No. NPF-39 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 1

Subject:

Limerick Generating Station, Unit 1 Changes to Emergency Response Data System Data Set Library Gentlemen Attached are changes to the Limerick Generating Station (LGS), Unit 1, Emergency Response Data System (ERDS) data set library. The ERDS is a direct, near real-time, electronic data link between a licensee's onsite computer system and the NRC's Operations Center that provides for the automated transmiselon d a limited data set d selected plant parameters in the event d an emergency. 10CFR50, Appendix E, requires that any hardware or software changes that affect the transmitted data points identified in the ERDS data set library be submitted to the NRC within 30 days after the changes are completed. Accordingly, these ERDS data set changes for LGS, Unit 1, are being submitted within 30 days after their implementation as required by 10CFR50, Appendix E, VI.3.a.

If you have any questions or require additional information, please do not hesitate to contact us.

Very truly yours, b

O%,

s G. A. Hunger, J.

Director - Licensing Attachment cc:

T. T. Martin, Administrator, USNRC, Region I (w/ attachment)

N. S. Perry, USNRC Senior Resident inspector, LGS (w/ attachment) 9604010432 960326 l

hDR ADOCK 05000352 PDR O'p

l ATTACHMENT Umerick Generating Station Unit 1 Emergency Response Data System Data Set Ubrary Changes

o NRC DATA POINT LIBRARY REFERENCE FILE I

Date:

03/20/9642 / :8 / n!

Reactor Unit (LM1 or LM2):

LM1 Data Feeder:

N/A NRC ERDS Parameter 12 (char):

NI POWER RNG Point ID (12 char >:

El130 Plant Spec Point Desc(40 char):

APRM A FLUX Generic /Cond Desc(32 char):

NUCLEAR INSTRUMENTS. POWER RANGE Analog /D_ieital:

A Ener Units / Die States (12 char):

Ener Units Conversion (40 char):

LINEAR Minimum Icatr Range (10 char):

0.0 Maximum Instr Range (10 char):

125.0 Zero Point Reference (6 char):

N/A Reference Point Notes (40 char):

N/A PROC or SENS:

S Number of Sensors (3 char):

1 I

How Processed (40 char):

N/A Sensor Locations (40 char):

IN CORE l

Alarm / Trip Set Points (40 char):

TRIP @ 0-680.SfiW+fl259%. MAX @ 11131M-s%. RUN MODE NI Detector Power Supply Cut-off N/A i

Power Level (15 char):

NI Detector Power Supply Turn on N/A i

Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A Transmitters (Y or N, if No provide correction curve)):

Level Reference Lee (WET or DRY):

N/A Unique System Desc.(600 char):

AVERAGE POWER RANGE MONITOR. ONE OF SIX APRM'S. THIS APRM IS THE AVERAGE OF 21 LOCAL POWER RANGE MONITORS. CONTINUOUSLY MONITORS POWER PRODUCTION AND PROVIDES TRIP SIGNALS TO RPS. RRCS AND RMCS.

l l

i I

l DPLIM OF fdG5

NRC DATA POINT LIBRARY REFERENCE FILE Date:

03/20/9m 2 / ' o ' o!

Reactor Unit (LM1 or LM2):

LM1 Data Feeder:

N/A NRC ERDS Paran.eter (12 char):

NI POWER RNG I

)

Point ID (12 char):

El131 Plant Spec Point Desc(40 char):

APRM B FLUX Generic /Cond Dese(32 char):

NUCLEAR INSTRUMENTS. POWER RANGE Analog / Digital:

A Ener Units / Dig States (12 char):

Ener Units Conversion (40 char):

LINEAR Mimmum Instr Range (10 char):

0.0 Maximum Instr Range (10 char):

125.0 Zero Point Reference (6 char):

N/A f

Reference Point Notes (40 char):

N/A i

PROC or SENS:

S Number of Sensors (3 char):

1 How Processed (40 char):

N/A Sensor Locations (40 char):

IN CORE Alarm / Trip Set Points (40 char):

TRIP @ 03SM8W+fi259%. MAX @ 117_DMG-5%, RUN MODE NI Detector Power Supply Cut.off N/A Power Level (15 char):

NI Detector Power Supply Turn-on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A Transmitters (Y or N, if No provide correction curve)):

Level Reference Leg (WET or DRY):

N/A Unique System Desc.(600 char):

AVERAGE POWER RANGE MONITOR. ONE OF SIX APRM'S. THIS APRM IS THE AVERAGE OF 22 LOCAL POWER RANGE MONITORS. CONTINUOUSLY MONITORS POWER PRODUCTION AND PROVIDES TRIP SIGNALS TO RPS. RRCS AND RMCS.

1

)

DPL 2M OF fi&G5

NRC DATA POINT LIBRARY REFERENCE FILE l

i 1

Date:

03/20/9m 2 / 'o ""

Reactor Unit (LM1 or LM2):

LM1 Data Feeder:

N/A NRC ERDS Parameter (12 char):

Ni POWER RNG Point ID (12 char):

E1106 l

Plant Spec Point Desc(40 char):

APRM C FLUX l

Generic /Cond Desc(32 char):

NUCLEAR INSTRUMENTS. POWER RANGE l

Analoe/ Digital:

A Ener Units / Dig States (12 char):

l Ener Units Conversion (40 char):

LINEAR I

Minimum Instr Range (10 char):

0.0 Maximum Instr Range (10 char):

1210 Zero Point Reference (6 char):

N/A Reference Point Notes (40 char):

N/A PROC or SENS:

S t

l Number of Sensors (3 char):

1 How Processed (40 char):

N/A Sensor Locations (40 char):

IN CORE 1

Alarm / Trip Set Points (40 char):

TRIP @ 0 ffiO48W+ fig 59%. MAX @ ljl.(H4G4%, RUN MODE NI Detector Power Supply Cut-off N/A Power Level (15 char):

l NI Detector Power Supply Turn-on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A Transmitters (Y or N, if No provide correction curve)):

Level Reference Leg (WET or DRY):

N/A Unique System Desc.(600 char):

AVERAGE POWER RANGE MONITOR. ONE OF SIX APRM'S. THIS APRM IS THE AVERAGE OF 21 LOCAL POWER RANGE MONITORS. CONTINUOUSLY MONITORS POWER PRODUCTION AND PROVIDES TRIP SIGNALS TO RPS. RRCS AND RMCS.

4 l

t

NRC DATA POINT LIBRARY REFERENCE FILE Date:

03/22/9e!2 / 's ""

Reactor Unit (LM1 or LM2):

LM1 Data Feeder:

N/A NRC ERDS Parameter (12 char):

NI POWER RNG Point ID (12 char):

E1107 Plant Spec Point Desc(40 char):

APRM D FLUX Generic /Cond Desc(32 char):

NUCLEAR INSTRUMENTS. POWER RANGE Analog / Digital:

A Ener Units / Dig States (12 char):

Ener Units Conversion (40 char):

LINEAR Minimum Instr Range (10 char):

00 Maximum Instr Range (10 char):

125.0 Zero Point Reference (6 char):

N/A Reference Point Notes (40 char):

N/A PROC or s. ENS:

S 4

Number of Sensors (3 char):

1 How Processed (40 char):

N/A 1

Sensor Locations (40 char):

IN CORE Alarmffrip Set Points (40 char):

TRIP @ O_66M8W+6259%. MAX @ 111.0M%%. RUN MODE NI Dete.ctor Power Supply Cut-otT N/A Power Level (15 char):

NI Detector Power Supply Turn-on N/A Power Level (15 char):

Instrument Fail re Mode (30 char):

N/A 9

Temperature Compensation for DP N/A Transmitters (Y or N, if No provide correction curve)):

Level Reference Leg (WET,_or DRY):

N/A Unique System Desc.(600 char):

AVERAGE POWER RANGE MONITOR. ONE OF SIX APRM'S. THIS APRM IS THE AVERAGE OF 22 LOCAL POWER RANGE MONITORS. CONTINUOUSLY MONITORS POWER PRODUCTION AND PROVIDES i TRIP SIGNALS TO RPS. RRCS AND RMCS.

DPL 4M OF 65GG

NRC DATA POINT LIBRARY REFERENCE FILE I

Date:

03/20/96!2 / "' ""

Reactor Unit (LM1 or LM2):

LM1 Data Feeder:

N/A NRC ERDS Parameter (12 char):

NI POWER RNG Point ID (12 char):

El108 Plant Spec Point Desc(40 char):

APRM E FLUX Generic /Cond Desc(32 char):

NUCLEAR INSTRUMENTS. POWER RANGE Analog /D_igital:

A Ener Units / Dig States (12 char):

Ener Units Conversion (40 char):

LINEAR Minimum Instr Ranee (10 char):

0.0 Maximum Instr Rance(10 char):

125.0 Zero Point Reference (6 char):

N/A Reference Point Notes (40 char):

N/A PROC or SENS:

S Number of Sensors (3 char):

1 How Processed (40 char):

N/A Sensor Locations (40 char):

IN CORE l

Alarm / Trip Set Points (40 char):

TRIP @ LLthi%sW+figa%. AL\\X @ ljl44%%. RUN MODE NI Detector Power Supply Cut-off N/A Power Level (15 char):

NI Detector Power Supply Turn-on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A Transmitters (Y or N, if No provide correction curve)):

Level Reference Leg (WET or DRY):

N/A Unique System Desc.(600 char):

AVERAGE POWER RANGE MONITOR. ONE OF SIX APRM'S. THIS APRM IS THE AVERAGE OF 21 LOCAL POWER RANGE MONITORS. CONTINUOUSLY MONITORS POWER PRODUCTION AND PROVIDES TRIP SIGNALS TO RPS. RRCS AND RMCS.

l DPLLM OFfi3%

NRC DATA POINT LIBRARY REFERENCE FILE Date:

03/20/96 ! 2 ! "' ! O !

Reactor Unit (LM1 or LM2):

LM1 Data Feeder:

N/A NRC ERDS Parameter (12 char):

NI POWER RNG Point ID (12 char):

Ell 32 Plant Spec Point Desc(40 char):

APRM F FLUX Generic /Cond Desc(32 char):

NUCLEAR INSTRUMENTS. POWER RANGE Analog / Digital:

A Ener Units / Die States (12 char):

t Ener Units Conversion (40 char):

LINE.G Minimum Instr Range (10 char):

0.0 Maximum Instr Range (10 char):

125.0 Zero Point Reference (6 char):

N/A Reference Point Notes (40 char):

N/A PROC or SENS:

S Number of Sensors (3 char):

1 How Processed (40 char):

N/A Sensor Locations (40 char):

IN CORE Alarm / Trip Set Points (40 char):

TRIP @ QSiO48W+figG9%, MAX C 1.11.014G4%, RUN MODE NI Detector Power Supply Cut-off N/A Power Level (15 char):

NI Detector Power Supply Turn-on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A

{

Temperature Compensation for DP N/A j

Transmitters (Y or N, if No provide correction curve)):

Level Reference Leg (WET or DRY):

N/A Unique System Desc.(600 char):

AVERAGE POWER RANOE MONITOR. ONE OF SIX APRM'S. THIS APRM IS THE AVERAOE OF 22 LOCAL POWER RANGE MONITORS. CONTINUOUSLY MONITORS POWER PRODUCTION AND PROVIDES TRIP SIGNALS TO RPS. RRCS AND RMCS.

DPL fiM OF fi&G5

NRC DATA POINT LIBRARY REFERENCE FILE Date:

I 12 / 18 / 01 Reactor Unit (LM1 or LM2):

ILM1 Data Feeder:

lN/A NRC ERDS Parameter (12 char):

1 NI SOURC RNG Point ID (12 char):

lEl109 Plant Spec Point Desc(40 char):

l ASRM COUNT RATE Generic /Cond Desc(32 char):

NUCLEAR INSTRUMENTS SOURCE RANGE Analog / Digital:

A Ener Units / Die States (12 char):

ICPS Ener Units Conversion (40 char):

LOG BASE 10 Minimum Instr Range (10 char):

1.0E 1 Maximum Instr Range (10 char):

11.0E+6 Zero Point Reference (6 char):

I COMPLEX Reference Point Notes (40 char):

lN/A PROC or SENS:

IS Number of Sensors (3 char):

1 How Processed (40 char):

N/A Sensor Locations (40 char):

IN VESSEL Alarm / Trip Set Points (40 char):

l 2.0E5 NI Detector Power Supply Cut.off N/A Power Level (15 char):

NI Detector Power Supply Turn-on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A Transmitters (Y or N, if No provide correction curve)):

Level Reference Leg (WET or DRY): IN/A Unique System Desc.(600 char):

SOURCE RANGE MONITORS. ONE OF FOUR SRM'S.

EACH DETECTOR EQUIPPED WITH MOTOR DRIVE MECH TO ALLOW INSERTION INTO/ RETRACTION FROM CORE. CAPABLE OF PRODUCING RPS TRIP WITH SHORTING LINKS REMOVED. SOURCE RANGE MONITOR POSITION JS VARIABLE BETWEEN 30 INCHES BELOW BO'ITOM OF ACTIVE FUEL TO 18 INCHES ABOVE CORE MIDPLANE.

l DPL UG OF fsG5

NRC DATA POINT LIBRARY REFERENCE FILE Date:

12 / 18/ 91 Reactor L~ nit (LM1 or I212):

LM1 Data Feeder:

N/A NRC ERDS Parameter (12 char):

NI SOURC RNG Point ID (12 char):

Ell 33 Plant Spec Point Desc(40 char):

B SRM COUNT RATE Generic /Cond Desc(32 char):

NUCLEAR INSTRUMENTS SOURCE RANGE Analog /D_ieital:

A Ener Units / Die States (12 char):

CPS Ener Units Conversion (40 char):

LOG BASE 10 Minimum Instr Rance(10 char):

1.0E 1 Maximum Instr Range (10 char):

1.0E+6 Zero Point Reference (6 char):

COMPLEX 1

Reference Point Notes (40 char):

N/A PROC or SENS:

S Number of Sensors (3 char):

1 How Processed (40 char):

N/A Sensor Locations (40 char):

IN VESSEL Alarm /frip Set Points (40 char):

2.0E5 NI Detector Power Supply Cut-off N/A Power Level (15 char):

NI Detector Power Supply Turn-on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A Transmitters (Y or N, if No provide correction curve)):

Level Reference Lee (WET or DRY):

N/A Unique System Desc.(600 char):

SOURCE RANGE MONITORS. ONE OF FOUR SRM'S.

EACH DETECTOR EQUIPPED WITH MOTOR DRIVE MECH TO ALLOW INSERTION INTO/ RETRACTION FROM CORE. CAPABLE OF PRODUCING RPS TRIP WITH SHORTING LINKS REMOVED. SOURCE RANGE MONITOR POSITION IS VARIABLE BETWEEN 30 INCHES BELOW BOTTOM OF ACTIVE FUEL TO 18 INCHES ABOVE CORE MIDPLANE.

DPL BW OF fiEGG

e e

NRC DATA POINT LIBRARY REFERENCE FILE Date:

12 / 18 / 91 Reactor Unit (LM1 or LM2):

LM1 Data Feeder:

N/A NRC ERDS Parameter (12 char):

NI SOURC RNG Point ID (12 char):

Ell 10 Plant Spec Point Desc(40 char):

C SRM COUNT RATE Generic /Cond Desc(32 char):

NUCLEAR INSTRUMENTS SOURCE RANGE Analog /D_igital:

A Ener Units / Die States (12 char):

CPS Ener Units Conversion (40 char):

LOG BASE 10 Minimum Instr Range (10 char):

1.0E 1 Maximum Instr Range (10 char):

1.0E+6 Zero Point Reference (6 char):

COMPLEX Reference Point Notes (40 char):

N/A PROC or SENS:

S Number of Sensors (3 char):

1 How Processed (40 char):

N/A Sensor Locations (40 char):

IN VESSEL Alarm / Trip Set Points (40 char):

2.0E5 NI Detector Power Supply Cut-off N/A Power Level (15 char):

NI Detector Power Supply Turn-on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A Transmitters (Y or N, if No provide correction curve)):

Level Reference Lee (WET or DRY):

N/A Unique System Desc.(600 char):

SOURCE RANGE MONITORS. ONE OF FOUR SRM'S, EACH DETECTOR EQUIPPED WITH MOTOR DRIVE MECH TO ALLOW INSERTION INTO/ RETRACTION FROM CORE. CAPABLE OF PRODUCING RPS TRIP WITH SHORTING LINKS REMOVED. SOURCE RANGE MONITOR POSITION IS VARIABLE BETWEEN 30 INCHES BELOW BOTTOM OF ACTIVE FUEL TO 18 INCHES ABOVE CORE MIDPLANE.

I J

NRC DATA POINT LIBRARY REFERENCE FILE Date:

12 / 18 / 91 Reactor Unit (LM1 or LM2):

LM1 Data Feeder:

N/A NRC ERDS Parameter (12 char):

NI SOURC RNG Point ID (12 char):

E1134 Plant Spec Point Desc(40 char):

D SRM COUNT RATE Generic /Cond Desc(32 char):

NUCLEAR INSTRUMENTS SOURCE RANGE Analog / Digital:

A i

Ener Units / Dig States (12 char):

CPS Ener Units Conversion (40 char):

LOG BASE 10 Minimum Instr Range (10 char):

1.0E.1 Maximum Instr Range (10 char):

1.0E+6 Zero Point Reference (6 char):

COMPLEX Reference Point Notes (40 char):

N/A PROC or SENS:

S Number of Sensors (3 char):

1 How Processed (40 char):

N/A Sensor Locations (40 char):

IN VESSEL Alarm / Trip Set Points (40 char):

2.0E5 NI Detector Power Supply Cut-off N/A Power Level (15 char):

NI Detector Power Supply Turn.on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A Transmitters (Y or N, if No provide correction curve)):

Level Reference Leg 6 VET or DRY):

N/A Unique System Desc.(600 char):

SOURCE RANGE MONITORS. ONE OF FOUR SRM'S.

EACH DETECTOR EQUIPPED WITH MOTOR DRIVE MECH TO ALLOW INSERTION INTO/ RETRACTION FROM CORE. CAPABLE OF PRODUCING RPS TRIP WITH SHORTING LINKS REMOVED. SOURCE RANGE MONITOR POSITION IS VARIABLE BETWEEN 30 INCHES BELOW BOTTOM OF ACTIVE FUEL TO 18 INCHES ABOVE CORE MIDPLLNE.

DPL10M OF fiEG5

NRC DATA POINT LIBRARY REFERENCE FILE Date:

12/ 18 / 91 Reactor Unit (LM1 or LM2):

Lall Data Feeder:

IN/A NRC ERDS Parameter (12 char):

NI SOURC RNG Point ID (12 char):

E1114 Plant Spec Point Desc(40 char):

A SRh1 POSITION Generic /Cond Desc(32 char):

NUCLEAR INSTRUh1ENTS SOURCE RANGE Analog /D_igital:

D Ener Units / Dig States (12 char):

IN/NOT IN Ener Units Conversion (40 char):

0= FULL IN / l=NOT IN Minimum Instr Range (10 char):

N/A Maximum Instr Ranee (10 char):

N/A Zero Point Reference (6 char):

N/A Reference Point Notes (40 char):

N/A PROC or SENS:

S Number of Sensors (3 char):

1 How Processed (40 char):

N/A Sensor Locations (40 char):

SHUTTLE TUBE Alarm / Trip Set Points (40 char):

N/A NI Detector Power Supply Cut-off N/A Power Level (15 char):

NI Detector Power Supply Turn-on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A Transmitters (Y or N, if No provide correction curve)):

Level Reference Leg 6 VET or DRY):

N/A Unique System Desc.(600 char):

NI SOURCE RANGE hlONITOR POSITION IS VARIABLE BETWEEN 30" BELOW BOTI'Oh! OF ACTIVE FUEL TO 18" ABOVE hilDPLLNE TULL IN).

(

l l

DPL 11M OF SFA

NRC DATA POINT LIBRARY REFERENCE FILE Date:

12 / 18 / 01 Reactor Unit (LM1 or LM2):

LM1 Data Feeder:

N/A NRC ERDS Parameter (12 char):

NI SOURC RNG Point ID (12 char):

E1138 Plant Spec Point Desc(40 char):

B SRM POSITION Generic /Cond Desc(32 char):

NUCLEAR INSTRUMENYS SOURCE RANGE Analog / Digital:

D Ener Units / Die States (12 char):

IN/NOT IN Ener Units Conversion (40 char):

0= FULL IN / !=NOT IN Minimum Instr Range (10 char):

N/A Maximum Instr Range (10 char):

N/A Zero Point Reference (G char):

N/A Reference Point Notes (40 char):

N/A PROC or SENS:

S Number of Sensors (3 char):

1 How Processed (40 char):

N/A Sensor Locations (40 char):

SHUTTLE TUBE Alarm / Trip Set Points (40 char):

N/A NI Detector Power Supply Cuteoff N/A Power Level (15 char):

NI Detector Po er Supply Turn on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A Transmitters (Y or N, if No provide correction curve)):

Level Reference Lee (WET or DRY):

N/A Unique System Desc.(600 char):

NI SOURCE RANGE MONITOR POSITION IS VARL\\BLE BETWEEN 30" BELOW BOTTOM OF ACTIVE FUEL TO 18" ABOVE MIDPLANE (FULL INK i

e 4 Geeee eeee e we speeeeeeeeee sees e e e DPL12M OF flirA

NRC DATA POINT LIBRARY REFERENCE FILE Date:

I 12 / 18 / 01 Reactor Unit (LM1 or LM2):

LM1 Data Feeder:

N/A NRC ERDS Parameter (12 char):

NI SOURC RNG Point ID (12 char):

Ell 15 Plant Spec Point Desc(40 char):

C SP.M POSITION Generic /Cond Desc(32 char):

l NUCLEAR INSTRUMENTS SOURCE RANGE Analog / Digital:

lD Ener Units / Die States (12 char):

IN/NOT IN Ener Units Conversion (40 char):

0= FULL IN / !=NOT IN Minimum Instr Range (10 char):

N/A Maximum Instr Ranee (10 char):

N/A Zero Point Reference (6 char):

lN/A Reference Point Notes (40 char):

lN/A PROC or SENS:

IS Number of Sensors (3 char):

1 How Processed (40 char):

N/A Sensor Locations (40 char):

SHUTTLE TUBE Alarm / Trip Set Points (40 char):

N/A NI Detector Power Supply Cut-off N/A Power Level (15 char):

NI Detector Power Supply Turn-on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A Transmitters (Y or N, if No provide correction curve)):

Level Reference Lee 6 VET or DRY):

N/A Unique System Desc.(600 char):

NI SOURCE RANGE MONITOR POSITION IS VARLABLE BETWEEN 30" BELOW BOTTOM OF ACTIVE FUEL TO 18" ABOVE MIDPLANE FULL Ih1.

l DPLlaM OF 654

~

NRC DATA POINT LIBRARY REFERENCE FILE Date:

12/18/ 91 Reactor Unit (LM1 or LM2):

LMi Data Feeder:

N/A NRC ERDS Parameter (12 char):

NI SOURC RNG Point ID (12 char):

El130 Plant Spec Point Desc(40 char):

D SRM POSITION Generic /Cond Desc(32 char):

NUCLEAR INSTRUMENTS SOURCE RANGE Analog /D_ieital:

D Ener Units / Die States (12 char):

IN/NOT IN Ener Units Conversion (40 char):

0= FULL IN / !=NOT IN Minimum Instr Range (10 char):

N/A Maximum Instr Range (10 char):

N/A Zero Point Reference (6 char):

N/A Reference Point Notes (40 char):

N/A l PROC or SENS:

S Number of Sensors (3 char):

1 How Processed (40 char):

N/A Sensor Locations (40 char):

SHUTTLE TUBE Alarm / Trip Set Points (40 char):

N/A NI Detector Power Supply Cut-off N/A Power Level (15 char):

NI Detector Power Supply Turn-on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A Transmitters (Y or N, if No provide correction curve)):

Level Reference Leg (WET or DRY):

N/A Unique System Desc.(600 char):

NI SOURCE RANGE MONITOR POSITION IS VARIABLE BETWEEN 30" BELOW BO'ITOM OF ACTIVE FUEL TO 18" ABOVE MIDPLANE (FULL INL l

l

.......w........................

DPL.L446 OF (1564

f i

NRC DATA POINT LIBRARY REFERENCE FILE l

Date:

12 / 18 / 01 Reactor Unit (LM1 or LM2):

LM1 Data Feeder:

N/A NRC ERDS Parameter (12 char):

REAC VES LVL Point ID (12 char):

E1240 Plant Spec Point Desc(40 char):

SHUTDOWN RANGE REACTOR LEVEL Generic /Cond Desc(32 char):

REACTOR VESSEL WATER LEVEL Analog /Dieital:

A Ener Units / Dig States (12 char):

INH 2O Ener Units Conversion (40 char):

LINEAR Minimum Instr Range (10 char):

0.0 Maximum Instr Range (10 char):

370.0 Zero Point Reference (6 char):

MSSKRT Reference Point Notes (40 char):

N/A PROC or SENS:

S Number of Sensors (3 char):

1 How Processed (40 char):

N/A Sensor Locations (40 char):

N/A Alarm / Trip Set Points (40 char):

1 NI Detector Power Supply Cut.off N/A Power Level (15 char):

NI Detector Power Supply Turn-on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N

Transmitters (Y or N, if No provide correction curve)):

Level Reference Leg (WET or DRY):

WET Unique System Desc.(600 char):

SHUTDOWN RANGE REACTOR LEVEL IS CALIBRATED FOR 120 DEGF WATER AT 0 PSIG IN VESSEL AND 80 DEGF IN THE DRYWELL.

INSTRUMENT ZERO IS AT THE BOTI'OM OF THE 1

STEAM DRYER ASSEMBLY SKIRT WHICH IS 527.5 INCHES ABOVE VESSEL ZERO (VESSEL BOTTOM HEAD). TOP OF ACTIVE FUELIS AT 161 INCHES.

l l

DPL1546 OF fd65 l

NRC DATA POINT LIBRARY REFERENCE FILE Date:

03/20/9m 2 / 'o ""

Reactor Unit (LM1 or LM2):

LM1 Data Feeder:

N/A NRC ERDS Parameter (12 char):

REAC VES LVL Point ID (12 char):

E1239 Plant Spec Point Desc(40 char):

UPSET RANGE REACTOR LEVEL Generic /Cond Desc(32 char):

REACTOR VESSEL WATER LEVEL Analog /D_igital:

A Engr Units / Die States (12 char):

INH 2O Ener Units Conversion (40 char):

LINEAR Minimum Instr Range (10 char):

0.0 Maximum Instr Range (10 char):

180.0 Zero Point Reference (6 char):

MSSKRT Reference Point Notes (40 char):

N/A PROC or SENS:

S Number of Sensors (3 char):

1 How Processed (40 char):

N/A Sensor Locations (40 char):

N/A Alarm / Trip Set Points (40 char):

N/A NI Detector Power Supply Cut off N/A Power Level (15 char):

NI Detector Power Supply Turn-on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N

Transmitters (Y or N, if No provide correction curve)):

Level Reference Lee (WET or DRY):

WET Unique System Desc.(600 char):

UPSET RANGE LEVEL IS CALIBRATED FOR SATURATED WATER STEAM CONDITIONS AT 10DM00 PISG IN THE VESSEL AND 135 DEGF IN THE DRYWELL. INSTRUMENT ZERO IS AT THE BOTTOM OF THE STEAM DRYER ASSEMBLY SKIRT WHICH IS 527.5 INCHES ABOVE VESSEL ZERO (VESSEL BOTTOM HEAD). TOP OF ACTIVE FUEL IS AT.161 INCHES.

DPL1GM OF fsGG

O NRC DATA POINT LIBRARY REFERENCE FILE Date:

12 / 18 / 91 Reactor Unit (LM1 or LM2):

LM1 Data Feeder:

N/A NRC ERDS Parameter (12 char):

REAC VES LVL Point ID (12 char):

E1419 Plant Spec Point Desc(40 char):

FUEL ZONE RANGE REACTOR LEVEL B Generic /Cond Desc(32 char):

REACTOR VESSEL WATER LEVEL Analog /D_igital:

A Ener Units / Die States (12 char):

INH 2O Ener Units Conversion (40 char):

LINEAR Minimum Instr Ranee (10 char):

-350 Maximum Instr Ranee (10 char):

100 Zero Point Reference (6 char):

MSSKRT Reference Point Notes (40 char):

N/A PROC or SENS:

S Number of Sensors (3 char):

1 How Processed (40 char):

N/A Sensor Locations (40 char):

N/A Alarm / Trip Set Points (40 char):

N/A NI Detector Power Supply Cut-off N/A Power Level (15 char):

NI Detector Power Supply Turn-on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N

Transmitters (Y or N, if No provide correction curve)):

Level Reference Lee 6 VET or DRY):

WET Unique System Desc.(600 char):

FUEL ZONE RANGE REACTOR LEVEL IS CALIBRATED FOR SATURATED WATER STEAM CONDITIONS AT 0 PSIG IN THE VESSEL AND DRYWELL WITH NO JET PUMP FLOW. INSTRUMENT ZERO IS AT THE BO'ITOM OF THE STEAM DRYER ASSEMBLY SKIRT WHICH IS 527.5 INCHES ABOVE VESSEL ZERO (VESSEL BO'ITOM HEAD). TOP OF ACTIVE FUEL IS AT.161 INCHES.

l DPL EM OF fi&G5

NRC DATA POINT LIBRARY REFERENCE FILE i

l Date:

12 / 18 / 91 Reactor Unit (LM1 or LM2):

Lhil i

Data Feeder:

N/A NRC ERDS Parameter (12 char):

REAC VES LYL Point ID (12 char):

E1339 l

Plant Spec Point Desc(40 char):

FUEL ZONE RANGE REACTOR LEVEL A Generic /Cond Desc(32 char):

REACTOR VESSEL WATER LEVEL Analog / Digital:

A Ener Units / Dig States (12 char):

INH 2O Ener Units Conversion (40 char):

LINEAR Minimum Instr Range (10 char):

e350 Maximum Instr Range (10 char):

e100 Zero Point Reference (6 char):

htSSKRT Reference Point Notes (40 char):

N/A l

PROC or SENS:

S Number of Sensors (3 char):

1 How Processed (40 char):

N/A Sensor Locations (40 char):

N/A Alarm / Trip Set Points (40 char):

N/A NI Detector Power Supply Cut off N/A l

Power Level (15 char):

NI Detector Power Supply Turnoon N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N

l Transmitters (Y or N, if No provide correction curve)):

Level Reference Leg (WET or DRY):

WET Unique System Desc.(600 char):

FUEL ZONE lb\\NOE REACTOR LEVEL IS CALIBRATED FOR SATURATED WATER STEAh!

CONDITIONS AT 0 PSIG IN THE VESSEL AND DRYWELL WITH NO JET PUh1P FLOW. INSTRUh1ENT ZERO IS AT THE BOTTOh! OF THE STEAhl DRYER ASSEh1BLY SKIRT WHICH IS 527.5 INCHES ABOVE VESSEL ZERO (VESSEL BOTTOh! HEAD). TOP OF ACTIVE FUEL IS AT e161 INCHES.

ee eeeeeeee eee eeee eee ee e e eeeeee e e e DPLJ316OFfd65

__m_+-

i NRC DATA POINT LIBRARY REFERENCE FILE i

l Date:

l 03/20/9e12 / 'e ""

Reactor Unit (LM1 or LM2):

ILM1 Data Feeder:

l N/A NRC ERDS Parameter (12 char):

I REAC VES LVL Point ID (12 char):

IE1418 Plant Spec Point Desc(40 char):

I WIDE RANGE REACTOR LEVEL B l

Generic /Cond Desc(32 char):

i REACTOR VESSEL WATER LEVEL l

Analog / Digital:

lA l

Ener Units / Dig States (12 char):

I INH 2O i

Ener Units Conversion (40 char):

\\ LINEAR l

Minimum Instr Range (10 char):

I-150 Maximum Instr Range (10 char):

l 60 Zero Point Reference (6 char):

1 MSSKRT l

Reference Point Notes (40 char):

IN/A j

PROC or SENS:

IS 1

l Number of Sensors (3 char):

1 How Processed (40 char):

N/A Sensor Locations (40 char):

N/A Alarm / Trip Set Points (40 char):

LOW LEVEL ISOLATIONS AT -38" & 120" NI Detector Power Supply Cut off N/A i

Power Level (15 char):

NI Detector Power Supply Turn on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N

Transmitters (Y or N, if No provide correction curve)):

Level Reference Lee (WET or DRY): IWET Unique System Desc.(600 char):

WIDE RANGE REACTOR LEVEL IS CALIBRATED FOR l

.lD:19000 PSIG IN THE VESSEL,135 DEGP IN THE DRYWELL AND 20 BTU /LB SUBCOOLING BELOW THE MIDDLE WATER LEVEL NOZZLE AND SATURATED CONDITIONS ABOVE THE MIDDLE WATER LEVEL NOZZLE WITH NO JET PUMP FLOW. INSTRUMENT ZERO IS AT THE BOTTOM OF THE STEAM DRYER ASSEMBLY SKIRT WHICH IS 527.5 INCHES ABOVE VESSEL ZERO (VESSEL BOTTOM HEAD). TOP OF ACTIVE FUEL IS AT 161" l

l l

eseeee eee e eeeeee e..... e e ee e ee ee s e l

DPL L9M OF fi36G

NRC DATA POINT LIBRARY REFERENCE FILE Date:

03/20/96'2 / !9 m' Reactor Unit (LM1 or LM2):

LM1 Data Feeder:

N/A NRC ERDS Parameter (12 char):

REAC VES LVL Point ID (12 char):

E1338 Plant Spec Point Desc(40 char):

WIDE RANGE REACTOR LEVEL A Generic /Cond Desc(32 char):

REACTOR VESSEL WATER LEVEL Analog /D_igital:

A Engr Units / Die States (12 char):

INH 2O Ener Units Conversion (40 char):

LINEAR Minimum Instr Range (10 char):

150 Maximum Instr Range (10 char):

60 Zero Point Reference (6 char):

MSSKRT Reference Point Notes (40 char):

N/A PROC or SENS:

S Number of Sensors (3 char):

1 How Processed (40 char):

N/A Sensor Locations (40 char):

N/A Alarm / Trip Set Points (40 char):

LOW LEVEL ISOLATIONS AT.38" &.120" NI Detector Power Supply Cut-off N/A Power Level (15 char):

NI Detector Power Supply Turn-on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N

Transmitters (Y or N, if No provide correction curve)):

Level Reference Leg (WET or DRY):

WET Unique System Desc.(600 char):

WIDE RANOE REACTOR LEVEL IS CALIBRATED FOR Ifl454000 PSIG IN THE VESSEL.135 DEGF IN THE DRYWELL AND 20 BTU /LB SUBCOOLING BELOW THE MIDDLE WATER LEVEL NOZZLE AND SATURATED CONDITIONS ABOVE THE MIDDLE WATER LEVEL NOZZLE WITH NO JET PUMP FLOW. INSTRUMENT ZERO IS AT THE BO'ITOM OF THE STEAM DRYER ASSEMBLY SKIRT WHICH IS 527.5 INCHES ABOVE VESSEL ZERO (VESSEL BO'ITOM HEAD). TOP OF ACTIVE FUEL IS AT 161" I

DPL 2fRG OF fd65

(

9 0

NRC DATA POINT LIBRARY REFERENCE FILE l

Date:

03/20/9e12 ! 19 ""

Reactor Unit (LM1 or LM2):

LM1 Data Feeder:

N/A NRC ERDS Parameter (12 char):

REAC VES LVL Point ID (12 char):

E1238 Plant Spec Point Desc(40 char):

NARROW RANGE REACTOR LEVEL C Generic /Cond Desc(32 char):

REACTOR VESSEL WATER LEVEL Analog / Digital:

A Ener Units / Die States (12 char):

INH 2O Ener Units Conversion (40 char):

LINEAR Minimum Instr Range (10 char):

0 Maximum Instr Range (10 char):

60 Zero Point Reference (G char):

MSSKRT Reference Point Notes (40 char):

N/A

)

PROC or SENS:

S i

Number of Sensors (3 char):

1 How Processed (40 char):

N/A Sensor Locations (40 char):

N/A Alarm / Trip Set Points (40 char):

SCRAM AT 12.5". LOW @30", HIGH @39" NI Detector Power Supply Cut-off N/A Power Level (15 char):

NI Detector Power Supply Turn-on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N

Transmitters (Y or N, if No provide correction curve)):

Level Reference Lee (WET or DRY):

WET Unique System Desc.(600 char):

NARROW RANGE REACTOR LEVEL IS CALIBRATED FOR SATURATED WATER STEAM CONDITIONS AT I

10_45M00 PSIG IN THE VESSEL AND 135 DEGF IN THE DRYWELL. INSTRUMENT ZERO IS AT THE BO'ITOM OF THE STEAM DRYER ASSEMBLY SKIRT WHICH IS 527.5 INCHES ABOVE VESSEL ZERO (VESSEL BO"ITOM HEAD). TOP OF ACTIVE FUEL IS AT.161 INCHES. RPS SCRAM AT +12.5 INCHES, TURBINE I

TRIP AT +54 INCHES. NORMNAL LEVEL AT +35 INCHES.

l DPL 21M OF fi5G5

NRC DATA POINT LIBRARY REFERENCE FILE Date:

03/20/9e!2 / 's > 91 Reactor Unit (LM1 or LM2):

LM1 Data Feeder:

N/A NRC ERDS Parameter (12 char):

REAC VES LVL Point ID (12 char):

E1237 Plant Spec Point Desc(40 char):

NARROW RANGE REACTOR LEVEL B Generic /Cond Desc(32 char):

REACTOR VESSEL WATER LEVEL Analog / Digital:

A Ener Units / Die States (12 char):

INH 2O Ener Units Conversion (40 char):

LINEAR Minimum Instr Range (10 char):

0 Maximum Instr Range (10 char):

so Zero Point Reference (6 char):

MSSKRT Reference Point Notes (40 char):

N/A PROC or SENS:

S Number of Sensors (3 char):

1 How Processed (40 char):

N/A Sensor Locations (40 char):

N/A Alarm / Trip Set Points (40 char):

SCRAM AT 12.5", LOW @30". HIGH @39" NI Detector Power Supply Cut-off N/A j

Power Level (15 char):

NI Detector Power Supply Turn-on N/A Power Level (15 char).

Instrument Failure Mode (30 char):

N/A j

Temperature Compensation for DP N

Transmitters (Y or N, if No provide correction curve)):

Level Reference Leg (WET or DRY):

WET Unique System Desc.(600 char):

NARROW RANGE REACTOR LEVEL IS CALIBRATED FOR SATURATED WATER STEAM CONDITIONS AT

.LO_45M00 PSIG IN THE VESSEL AND 135 DEGF IN THE DRYWELL. INSTRUMENT ZERO IS AT THE BO'ITOM OF THE STEAM DRYER ASSEMBLY SKIRT WHICH IS 527.5 INCHES ABOVE VESSEL ZERO (VESSEL BOTTOM HEAD). TOP OF ACTIVE FUEL IS AT.161 INCHES. RPS SCRAM AT +12.5 INCHES, TURBINE TRIP AT +54 INCHES. NORhlNAL LEVEL AT +35

[NCHES.

DPL 22M OF fi365

NRC DATA POINT LIBRARY REFERENCE FILE I

Date:

03/20/9612 / '

Reactor Unit (LM1 or LM2):

LM1 Data Feeder:

N/A NRC ERDS Parameter (12 char):

REAC VES IXL Point ID (12 char):

E123G Plant Spec Point Desc(40 char):

NARROW RANGE REACTOR LEVEL A Generic /Cond Desc(32 char):

REACTOR VESSEL WATER LEVEL Analoc/ Digital:

A Ener Units / Die States (12 char):

INH 2O Ener Units Conversion (40 char):

LINEAR Minimum Instr Range (10 char):

0 Maximum Instr Range (10 char):

60 Zero Point Reference (G char):

MSSKRT Reference Point Notes (40 char):

N/A PROC or SENS:

IS Number of Sensors (3 char):

l1 How Processed (40 char):

lN/A Sensor Locations (40 char):

N/A Alarm / Trip Set Points (40 char):

SCRAM AT 12.5", LOW @30", HIGH Ca 39" NI Detector Power Supply Cut.off N/A Power Level (15 char):

NI Detector Power Supply Turn-on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N

Transmitters (Y or N, if No provide correction curve)):

Level Reference Leg (WET or DRY):

WET Unique System Desc.(600 char):

NARROW RANGE REACTOR LEVEL IS CALIBRATED FOR SATURATED WATER STEAM CONDITIONS AT l

1Q04000 PSIG IN THE VESSEL AND 135 DEGF IN THE DRYWELL. INSTRUMENT ZERO IS AT THE BOTTOM OF THE STEAM DRYER ASSEMBLY SKIRT WHICH IS 527.5 INCHES ABOVE VESSEL ZERO (VESSEL BOTTOM HEAD). TOP OF ACTIVE FUEL IS AT.161 INCHES. RPS SCRAM AT +12.5 INCHES. TURBINE I

TRIP AT +54 INCHES. NORh1NAL LEVEL.4T +35 INCHES.

l DPL Z146 OF 65G4

l NRC DATA POINT LIBRARY REFERENCE FILE 1

l Date:

03/20/942/'S ""

Reactor Unit (LM1 or LM2h LM1 Data Feeder:

N/A NRC ERDS Parameter (12 char):

htAIN FD FLOW Point ID (12 char):

E1241 Plant Spec Point Desc(40 char):

TOTAL FEEDWATER FLOW Generic /Cond Desc(32 char):

FEEDWATER FLOW INTO REACTOR Analog / Digital:

A Ener Units / Die States (12 char):

MLB/HR Ener Units Conversion (40 char):

LINEAR Minimum Instr Range (10 char):

0 Maximum Instr Range (10 chark 21 Zero Point Reference (6 charh N/A Reference Point Notes (40 char):

N/A PROC or SENS:

S Number of SensotM3 3ar):

1 How Processed (40 char):

LINEAR Sensor Locations (40 charh AritR 6TH FW HEATERS

{

Alarm / Trip Set Points (40 cham:

N/A NI Detector Power Supply Cut-off N/A Power Level (15 charh NI Detector Power Supply Turn-on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A Transmitters (Y or N, if No provide correction curve)k Level Reference Lee (WET or DRYh N/A Unique System Desc.(600 char):

MAIN FEED FLOW IS THE SUMMATION OF THE GTH FEEDWATER HEATER OUTLET FLOWS FOR THE THREE FEEDWATER LOOPS. RATED FEEDWATER FLOW IS 1544 MLB/HR.

DPL 214G OF fdGG

NRC DATA POINT LIBRARY REFERENCE FILE Date:

12/ 18/91 Reactor Unit (D11 or D12):

LM1 Data Feeder:

N/A NRC ERDS Parameter (12 char):

RCIC FLOW Point ID (12 char):

E1340 Plant Spec Point Desc(40 char):

RCIC SYSTEM FLOW Generic /Cond Desc(32 char):

REACTOR CORE ISOLATION COOLING FLOW Analog /D_igital:

A Ener Units / Dig States (12 char):

GPM Ener Units Conversion (40 char):

LINEAR Minimum Instr Range (10 char):

0 Maximum Instr Range (10 char):

700 Zero Point Reference (6 char):

N/A Reference Point Notes (40 char):

N/A PROC or SENS:

S

_ Number of Sensors (3 char):

1 How Processed (40 char):

N/A Sensor Locations (40 char):

RCIC PUMP DISCHARGE Alarm / Trip Set Points (40 char):

LOW FLOW AT 95 GPM NI Detector Power Supply Cut-off N/A Power Level (15 char):

NI Detector Power Supply Turn-on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A Transmitters (Y or N, if No provide correction curve)):

Level Reference LegGVET or DRY):

N/A Unique System Desc.(600 char):

RCIC AUTOMATICALLY STARTS ON LOW. LOW REACTOR LEVEL AT.38. RCIC STEAM ADMISSION VALVE CLOSES @ +54 INCHES RX WATER LEVEL.

RCIC ISOLATES AT 64.5 PSIG RX PRESSURE. RATED FLOW IS 616 GPM.

i l

DPL 25M OF fsG5

9 NRC DATA POINT LIBRARY REFERENCE FILE i

l Date:

03/20/9612 / IS / "'

Reactor Unit (LM1 or LM2):

LM1 Data Feeder:

N/A l

NRC ERDS Parameter (12 chari:

RCS PRESSURE Point ID (12 char):

E1234 Plant Spec Point Desc(40 char):

NARROW RANGE REACTOR PRESS Generic /Cond Desc(32 char):

RX COOLANT SYSTEM PRESSURE Analog / Digital:

A Ener Units / Die States (12 char):

PSIG Ener Units Conversion (40 char):

LINEAR l

Minimum Instr Range (10 char):

200850 Maximum Instr Range (10 char):

1100M50 Zero Point Reference (6 char):

N/A Reference Point Notes (40 char):

N/A PROC or SENS:

S Number of Sensors (3 char):

1 How Processed (40 char):

N/A Sensor Locations (40 char):

N/A Alarm / Trip Set Points (40 char):

HIGH @ 1Q534020, SCRAM HI @l0DfMO:W. SCRAM LOW

@756 i

NI Detector Power Supply Cut.off N/A Power Level (15 char):

NI Detector Power Supply Turn-on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A Transmitters (Y or N, if No provide correction curve)):

Level Reference Leg (WET or DRY):

N/A Unique System Desc.(600 char):

REACTOR VESSEL PRESSURE IS SENSED IN STEAM DOME AREA.

DPL 2fRG OF fi565

l NRC DATA POINT LIBRARY REFERENCE FILE l

l Date:

l 03/20/9cg2 : 'e 'u Reactor Unit (LM1 or LM2):

ILM1 Data Feeder:

I N/A NRC ERDS Parameter (12 char):

l RCS PRESSURE Point ID (12 char):

lE1430 Plant Spec Point Desc(40 char):

I UPSET RANGE REACTOR PRESSURE B Generic /Cond Desc(32 char):

I RX COOLANT SYSTEM PRESSURE Analog /D_igital:

IA Ener Units / Die States (12 char):

lPSIG Ener Units Conversion (40 char):

LINEAR Minimum Instr Range (10 char):

0 Maximum Instr Range (10 char):

1500 Zero Point Reference (6 char):

N/A Reference Point Notes (40 char):

lN/A PROC or SENS:

S Number of Sensors (3 char):

11 How Processed (40 char):

N/A Sensor Locations (40 char):

N/A l

Alarm / Trip Set Points (40 char):

HICH @ 19334420. SCRAM HI @l0Df40KSCRAM LOW

@756 NI Detector Power Supply Cut off N/A Power Level (15 char):

NI Detector Power Supply Turn-on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A Transmitters (Y or N, if No provide correction curve)):

Level Reference Lee (WET or DRY):

N/A Unique System Desc.(600 char):

REACTOR VESSEL PRESSURE IS SENSED IN STEAM DOME AREA.

l l

l l

1 l

l 1~

i l

DPL 2BG OF (1564 i

)

l l

I l

NRC DATA POINT LIBRARY REFERENCE FILE Date:

l 03/20/9e 12 ! ! = ' m Reactor Unit (LM1 or LM2):

LM1 l

Data Feeder:

N/A NRC ERDS Parameter (12 char):

RCS PRESSURE Point ID (12 char):

E1353 Plant Spec Point Desc(40 char):

UPSET RANGE REACTOR PRESSURE A Generic /Cond Desc(32 char):

RX COOLANT SYSTEM PRESSURE Analog / Digital:

A Ener Units / Dig States (12 char):

PSIG Ener Units Conversion (40 char):

LINEAR Minimum Instr Range (10 char):

0 Maximum Instr Range (10 char):

1500 Zero Point Reference (6 char):

N/A Reference Point Notes (40 char):

N/A PROC or SENS:

S Number of Sensors (3 char):

1 How Processed (40 char):

N/A Sensor Locations (40 char):

N/A Alarm / Trip Set Points (40 char):

HIGH @ l0fd4MO. SCRAM HI @p. SCRAM LOW

@ 756 NI Detector Power Supply Cut-off N/A Power Level (15 char):

NI Detector Power Supply Turn-on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A Transmitters (Y or N, if No provide correction curve)):

Level Reference Leg (WET or DRY):

N/A Unique System Desc.(600 char):

REACTOR VESSEL PRESSURE IS SENSED IN STEAM DOME AREA.

DPL 2fR6 OF Cs45

4 NRC DATA POINT LIBRARY REFERENCE FILE Date:

12 / 18 / 91 Reactor Unit (LM1 or LM2):

Lh11 Data Feeder:

N/A NRC ERDS Parameter (12 char):

HPCI FLOW Point ID (12 char):

E1420 Plant Spec Point Desc(40 char):

HPCI SYSTEh! FLOW Generic /Cond Desc(32 char):

HIGH PRESSURE COOLANT INJECTION FLOW Analog / Digital:

A Ener Units / Dig States (12 char):

KGPh1 Engr Units Conversion (40 char):

LINEAR Minimum Instr Range (10 char):

0.0 Maximum Instr Range (10 char):

6.0 Zero Point Reference (6 char):

N/A Reference Point Notes (40 char):

N/A PROC or SENS:

S Number of Sensors (3 char):

1 How Processed (40 char):

N/A Sensor Locations (40 char):

PUhlP DISCHARGE LINE Alarm / Trip Set Points (40 c? : U:

LOW @ 300 GPht. TRIP @+54 INCHES NI Detector Power Supp v Dut-off N/A Power Level (15 char):

NI Detector Power Supply Turn-on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A Transmitters (Y or N, if No provide correction curve)):

Level Reference Leg (WET or DRY):

N/A Unique System Desc.(600 char):

HPCI AUTOhlATICALLY INITIATES ON LOW. LOW LEVEL @.38 INCHES OR HIGH DRYWELL PRESSURE

@ 1.68 PSIG. RATED AT 5600 GPhi @ 1400 PSIG.

DISCHARGE TO VESSEL VIA CORE SPRAY LOOP "B" AND FEEDWATER LINE "A". HPCI TRIPS ON DIV 2 OR 4 ISOLATION. HIGH TURB EXHAUST AT 150 PSIG, LOW STEAh! LINE SUPPLY PRESSURE @l5 INCHES VAC OR HI RX WATER LEVEL @+54 INCHES.

l DPL 22M OF fd6G

1 e

NRC DATA POINT LIBRARY REFERENCE FILE Date:

12 / 18 / 01 Reactor Unit (LM1 or LM2):

LM1 Data Feeder:

N/A NRC ERDS Parameter (12 char):

LPCI FLOW Point ID (12 char):

E1341 Plant Spec Point Desc(40 char):

A RHR SYSTEM FLOW Generic /Cond Dese(32 char):

LPCI FLOW Analog / Digital:

A Ener Units / Die States (12 char):

KGPM Ener Units Conversion (40 char):

LINEAR Minimum Instr Range (10 char):

0 Maximum Instr Range (10 char):

12 Zero Point Reference (6 char):

N/A Reference Point Notes (40 char):

N/A PROC or SENS:

S Number of Sensors (3 char):

1 How Processed (40 char):

N/A Sensor Locations (40 char):

DOWNSTREAM OF A RHR HEAT EXCHANGER farm / Trip Set Points (40 char):

N/A N; Detector Power Supply Cuteoff N/A Power Level (15 char):

NI Detector Power Supply Turn-on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A Transmitters (Y or N, if No provide correction curve)):

Level Reference Lee (WET or DRY):

N/A Unique System Dese.(600 char):

LPCI MODE OF RHR IS AUTOMATICALLY INITIATED ON LOWeLOWeLOW LEVEL 3 e129 INCHES OR THE COMBINATION OF LOW RX PRESSURE @ 455 PSIG AND HIGH DRYWELL PRESSURE @ 1.G8 PSIG. EACH RHR PUMP IS RATED AT 10000 GPM @ 260 PSIG.

eeeeeeeeee eeeeeeeeeeeeeeeeeeeeeee DPL 30M OF fliGG

NRC DATA POINT LIBRARY REFERENCE FILE

\\

Date:

1 12/18/91 Reactor Unit (LM1 or LM2):

LM1 Data Feeder:

N/A NRC ERDS Parameter (12 char):

LPCI FLOW Point ID (12 char):

E1421 l

Plant Spec Point Desc(40 char):

B RHR SYSTEM FLOW Generic /Cond Desc(32 char):

LPCI FLOW l

Analog / Digital:

A l

Ener Units / Dig States (12 char):

KGPM Ener Units Conversion (40 char):

LINEAR Minimum Instr Range (10 char):

0 l

Maximum Instr Ranee (10 char):

12 Zero Point Reference (6 char):

N/A Reference Point Notes (40 char):

N/A PROC or SENS:

a Number of Sensors (3 char):

1 How Processed (40 char):

N/A Sensor Locations (40 char):

DOWNSTREAM OF B RHR HEAT EXCHANGER Alarm / Trip Set Points (40 char):

N/A NI Detector Power Supply Cut-off N/A

{

Power Level (15 char).

NI Detector Power Supply Turn-on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A l

Temperature Compensation for DP N/A Transmitters (Y or N, if No provide correction curve)):

Level Reference Leg (WET or DRY):

N/A Unique System Desc.(600 char):

LPCI MODE OF RHR IS AUTOMATICALLY INITIATED ON LOW LOW. LOW LEVEL @ 129 INCHES OR THE COMBINATION OF LOW RX PRESSURE @ 455 PSIG AND HIGH DRYWELL PRESSURE @ 1.68 PSIG. EACH RHR PUMP IS RATED AT 10000 GPM 7 2 PStu.

i f

l l

I DPL 11M OF fd65

~

o NRC DATA POINT LIBRARY REFERENCE FILE Date:

12 / 18 /91 Reactor Unit (LM1 or LM2):

Lhil Data Feeder:

N/A NRC ERDS Parameter (12 char):

LPCI FLOW Point ID (12 char):

E1466 Plant Spec Point Desc(40 char):

C RHR SYSTEM FLOW Generic /Cond Desc(32 char):

LPCI FLOW

{

Analog / Digital:

A Ener Units / Die States (12 char):

KGPhi i

Ener Units Conversion (40 char):

LINEAR Minimum Instr Range (10 char):

0 Maximum Instr Range (10 char):

12 Zero Point Reference (6 char):

N/A Reference Point Notes (40 char):

N/A PROC or SENS:

S Number of Sensors (3 char):

1 How Processed (40 char):

N/A Sensor Locations (40 char):

DOWNSTREAM OF A RHR HT EXCHANGER CROSSTIE Alarm / Trip Set Points (40 char):

N/A NI Detector Power Supply Cut-off N/A Power Level (15 char):

NI Detector P<

er Supply Turn-on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A Transmitters (Y or N, if No provide correction curve)):

Level Reference Lee (WET or DRY):

N/A Unique System Desc.(600 char):

LPCI MODE OF RHR IS AUTOMATICALLY INITIATED ON LOW-LOW LOW LEVEL @.129 INCHES OR THE COMBINATION OF LOW RX PRESSURE @ 455 PSIG AND HIGH DRYWELL PRESSURE @ 1.68 PSIG. EACH RHR PUMP IS RATED AT 10000 GPM @ 260 PSIC.

DPL 32M OF fiE64

NRC DATA POINT LIBRARY REFERENCE FILE Date:

12 / 18 / 91 Reactor Unit (LM1 or LM2):

LM1 Data Feeder:

N/A j@C ERDS Parameter (12 char):

LPCI FLOW

. Pcint ID (12 char):

E1506 (Piant Spec Point Desc(40 char):

I D RHR SYSTEM FLOW

' Generic /Cond Desc(32 char):

LPCI FLOW galog/ Digital:

A j@gr Units / Die States (12 char):

KGPM go$r Units Conversion (40 char):

LINEAR Minimum Instr Range (10 char):

o l

Maximttm Instr Range (10 char):

12 Zero Point Reference (6 char):

N/A Reference Point Notes (40 char):

N/A P_ ROC or SENS-S Number of Sensorsi3 char):

1 How Processed (40 char)L N/A Sensor Locations (40 char):

DOWNSTREAM OF B RHR HT EXCHANGER CROSSTIE Alarm / Trip Set Points (40_ char):

N/A NI Detector Power Supply Cut-og N/A Power Level (15 char):

NI Detector Power Supply TuraTon N/A Power Level (15 char):

J Instrument Failure Moda(30 char):

N/A i

Temperature Compensation for DP N/A Transmitters (Y or N, if No provide correction curve)):

Level Reference Leg (WET or DRY):

N/A j

Unique System Desc.(600 char):

LPCI MODE OF RHR IS AUTOMATICALLY INITIATED

{

ON LOW-LOW. LOW LEVEL @.129 INCHES OR THE COMBINATION OF LOW RX PRESSURE @ 455 PSIG AND HIGH DRYWELL PRESSURE @ 1.68 PSIG. EACH RHR PUMP IS RATED AT 10000 GPM @ 260 PSIG.

I DPL MM OF fdG5

NRC DATA POINT LIBRARY REFERENCE FILE Date:

I 12 / 18 / 01 i Reactor Unit (LM1 or LM2):

LM1

> Data Feeder:

N/A NRC ERDS Parameter (12 char):

CR SPRAY FL i Point ID (12 char):

E1342 I

i Plant Spec Point Desc(40 char):

A CORE SPRAY FLOW l Generic /Cond Desc(32 char):

CORE SPRAY COOLING SYSTEM FLOW

! Analog / Digital:

A I Ener Units / Dig States (12 char):

KGPM i Ener Units Conversion (40 char):

LINEAR Minimum Instr Range (10 char):

0 Maximum Instr Range (10 char):

8.8 Zero Point Reference (G char):

N/A I Reference Point Notes (40 char):

N/A

' PROC or SENS:

S

! Number of Sensors (3 char):

1 How Processed (40 char):

N/A Sensor Locations (40 char):

DOWNSTREAM OF A&C CS PPS ON DISCH PIPING Alarm / Trip Set Points (40 char):

N/A NI Detector Power Supply Cut off N/A Power Level (15 char):

NI Detector Power Supply Turn-on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A Transmitters (Y or N, if No provide correction curve)):

Level Reference Lee (WET or DRYh N/A Unique System Desc.(600 char):

CORE SPRAY AUTOhlATICALLY INITIATES ON LOW.

LOW LOW REACTOR WATER LEVEL @.129 INCHES OR THE COMBINATION OF LOW RX PRESSURE @ 455 PSIG AND HIGH DRYWELL PRESSURE @ 1.68 PSIG.

EACH CORE SPRAY PUMP IS RATED AT 3175 GPM @

145 PSIG. EACH CORE SPRAY LOOP CONSISTS OF 2 CORE SPRAY PUMPS.

i DPL 14M OF (1565 l

1

NRC DATA POINT LIBRARY REFERENCE FILE Date:

l 12 /18 / 91 Reactor Unit (LM1 or LM2):

ILM1 Data Feeder:

lN/A l

NRC ERDS Parameter (12 char):

l CR SPRAY FL Point ID (12 char):

lE1422 Plant Spec Point Desc(40 char):

B CORE SPRAY FLOW Generic /Cond Desc(32 char):

CORE SPRAY COOLING SYSTEM FLOW Analog /D_ieital:

A Ener Units / Dig States (12 char):

KGPM Ener Units Conversion (40 char):

LINEAR Minimum Instr Range (10 char):

0 Maximum Instr Range (10 char):

8.8 Zero Point Reference (6 char):

N/A

{

Reference Point Notes (40 char):

N/A PROC or SENS:

IS Number of Sensors (3 char):

1 How Processed (40 char):

N/A Sensor Locations (40 char):

DOWNSTREAM OF B&D CS PPS ON DISCH PIPING Alarm / Trip Set Points (40 char):

N/A NI Detector Power Supply Cut-off N/A Power Level (15 char):

NI Detector Power Supply Turn-on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A Transmitters (Y or N, if No provide correction curve)):

Level Reference LegGVET or DRY):

N/A Unique System Desc.(600 char):

CORE SPRAY AUTOMATICALLY INITIATES ON LOW.

LOW LOW REACTOR WATER LEVEL @.129 INCHES OR THE COMBINATION OF LOW RX PRESSURE @ 455 PSIG AND HIGH DRYWELL PRESSURE @ 1.68 PSIG.

EACH CORE SPRAY PUMP IS RATED AT 3175 GPM @

145 PSIG. EACH CORE SPRAY LOOP CONSISTS OF 2 CORE SPRAY PUMPS.

l DPL 35M OF 6565

NRC DATA POINT LIBRARY REFERENCE FILE Date:

l 12 /18 / 91 Reactor Unit (LM1 or LM2):

LMi Data Feeder:

N/A NRC ERDS Parameter (12 char):

DW FD SMP LV Point ID (12 char):

E1192 Plant Spec Point Desc(40 char):

DRYWELL FLOOR DRAIN SUMP LEVEL Generic /Cond Desc(32 char):

DRYWELL FLOOR DRAIN SUMP LEVEL Analog / Digital:

A Ener Units / Dig States (12 char):

GAL Ener Units Conversion (40 char):

QUADRATIC Minimum Instr Ranee (10 char):

5.567 Maximum Instr Range (10 char):

400.224 Zero Point Reference (G char):

N/A Reference Point Notes (40 char):

N/A PROC or SENS:

S Number of Sensors (3 char):

I How Processed (40 char):

N/A Sensor Locations (40 char):

DOWNSTREAM OF HV61 *ll Alarm / Trip Set Points (40 char):

19.5 INCHES INCREASING NI Detector Power Supply Cut-off N/A Power Level (15 char):

NI Detector Power Supply Turn-on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A Transmitters (Y or N, if No provide correction curve)):

Level Reference Leg (WET or DRY):

N/A Unique System Desc.(600 char):

DRYWELL FLOOR DRAIN SUMP CAPACITY IS 1080 GALLONS.

DPL. fiM OF fiF4 3

l NRC DATA POINT LIBRARY REFERENCE FILE i

Date:

12 / 18 / 91 Reactor Unit (LM1 or LM2):

LM1 Data Feeder:

N/A NRC ERDS Parameter (12 char):

EFF GAS RAD Point ID (12 char):

4TE076 Plant Spec Point Desc(40 char):

N STACK TOTAL EFFLUENT Generic /Cond Desc(32 char):

RADIOACTIVITY OF RELEASED GASSES Analog / Digital:

A Ener Units / Die States (12 char):

M Ct/S Ener Units Conversion (40 char):

Minimum Instr Range (10 char):

Maximum Instr Range (10 char):

Zero Point Reference (6 char):

N/A Reference Point Notes (40 char):

N/A PROC or SENS:

P Number of Sensors (3 char):

N/A How Processed (40 char):

N/A Sensor Locations (40 char):

NORTH STACK SAMPLE GRID Alarm / Trip Set Points (40 char):

ALERT @ 1.08E4 MC1/S.HIGIf @1.08E5 MCI /S NI Detector Power Supply Cut off N/A Power Level (15 char):

NI Detector Power Supply Turn-on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A Transmitters (Y or N, if No provide correction curve)):

Level Reference Lee (WET or DRY):

N/A Unique System Desc.(600 char):

l l

I DPL, aI44 OF 6565

NRC DATA POINT LIBRARY REFERENCE FILE Date:

12/ 18 / 91 Reactor Unit (LM1 or LM2):

LM1 Data Feeder:

N/A NRC ERDS Parameter (12 char):

CND A/E RAD Point ID (12 char):

E1088 Plant Spec Point Desc(40 char):

STEAh! JET AIR EJECTOR RAD MON Generic /Cond Desc(32 char):

CONDENSER AIR EJECTOR RADIOACTI\\TI'Y Analog / Digital:

A Ener Units / Die States (12 char):

MR/HR j

Ener Units Conversion (40 char):

LOG BASE 10 Minimum Instr Range (10 char):

0 Maximum Instr Range (10 char):

1.0E6 Zero Point Reference (6 char):

N/A Reference Point Notes (40 char):

N/A PROC or SENS:

S Number of Sensors (3 char):

1 How Processed (40 char):

N/A Sensor Locationst40 char):

BETWEEN AFTER CONDENSER & HOLDUP PIPE Alarm / Trip Set Points (40 char):

1.47E4 MR/HR NI Detector Power Supply Cut-off N/A Power Level (15 char):

NI Detector Power Supply Turn-on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A Transmitters (Y or N, if No provide correction curve)):

Level Reference Lee (WET or DRY):

N/A Unique System Desc.(600 char):

NORMAL SAMPLE IS OBTAINED FROM GASEOUS RADWASTE. RECOMBINATION SYSTEM BETWEEN AFTER CONDENSER AND HOLDUP PIPE.

DPL 3f96 OF (1565

~

NRC DATA POINT LIBRARY REFERENCE FILE l

Date:

12 / 18 / 91 Reactor Unit (LM1 or LM2):

LM1 Data Feeder:

N/A NRC ERDS Parameter (12 char):

DW RAD Point ID (12 char):

1RA191 Plant Spec Point Desc(40 char):

DRYWELL AREA POST LOCA

)

Generic /Cond Desc(32 char):

RAD LEVEL IN THE DRYWELL Analoeillicital:

A Ener Units / Die States (12 char):

R/HR Ener Units Conversion (40 char):

Minimum Instr Range (10 char):

IE2 R/HR.1 CPM Maximum Instr Range (10 char):

IE8 R/HR. IE6 CPM Zero Point Reference (6 char):

N/A Reference Point Notes (40 char):

N/A PROC or SENS:

S i

Number of Sensors (3 char):

N/A How Processed (40 char):

N/A Sensor Locations (40 char):

DRYWELL, ELEVATION 258', AZIMUTH 3300 Alarm / Trip Set Points (40 char):

ALERT @ 50 R/HR. HIGH @ 100 R/HR NI Detector Power Supply Cut-off N/A Power Level (15 char):

NI Detector Power Supply Turn-on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A Transmitters (Y or N, if No provide correction curve)):

Level Reference Lee (WET or DRY):

N/A Unique System Desc.(600 char):

ONE OF FOUR GAMhLA ION CHAMBER SENSORS FOR THE PRIMARY CONTAINMENT. MONITORS GROSS RADIOACTIVITY PRESENT IN CONTAINMENT ATMOSPHERE. SENSORS ARE LOCATED IN SEPERATE AREAS OF CONTAINMENT TO PROVIDE INDEPENDENT MEASUREMENT AND TO VIEW LARGE FRACTIONS OF THE CONTAINMENT VOLUME.

l DPL 33M OF 6565

NRC DATA POINT LIBRARY REFERENCE FILE Date:

12 / 18 / 91 Reactor Unit (LM1 or LM2):

LM1 Data Feeder:

N/A NRC ERDS Parameter (12 char):

DW RAD Point ID (12 char):

2RA191 Plant Spec Point Desc(40 char):

DRYWELL AREA POST LOCA Generic /Cond Desc(32 char):

RAD LEVEL IN THE DRYWELL Analog / Digital:

A Ener Units / Die States (12 char):

R/HR Ener Units Conversion (40 char):

Minimum Instr Range (10 char):

IE2 Maximum Instr Range (10 char):

IE8 Zero Point Reference (6 char):

N/A Reference Point Notes (40 char):

N/A PROC or SENS:

S Number of Sensors (3 char):

N/A How Processed (40 char):

N/A Sensor Locations (40 char):

DRYWELL. ELEVATION 258' 450 AZIMUTH Alarm / Trip Set Points (40 char):

ALERT @ 50 R/HR. HIGH @ 100 R/HR NI Detector Power Supply Cut-off N/A Power Level (15 char):

NI Detector Power Supply Turn-on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A Transmitters (Y or N, if No provide correction curve)):

Level Reference Lee (WET or DRY):

N/A Unique System Desc.(600 char):

ONE OF FOUR GAMMA ION CHAMBER SENSORS FOR THE PRIMARY CONTAINMENT. MONITORS OROSS RADIOACTIVITY PRESENT IN CONTAINMENT ATMOSPHERE. SENSORS ARE LOCATED IN SEPERATE AREAS OF CONTAINMENT TO PROVIDE INDEPENDENT MEASUREMENT AND TO VIEW LAROE FRACTIONS OF THE CONTAINMENT VOLUME.

DPL10M OF fsG4

=.-

O NRC DATA POINT LIBRARY REFERENCE FILE l

i Date:

12/ 18 / 91 Reactor Unit (LM1 or LM2):

Lhil Data Feeder:

N/A NRC ERDS Parameter (12 char):

DW RAD Point ID (12 char):

3 RAID 1 Plant Spec Point Dese(40 char):

DRYWELL AREA POST LOCA Generic /Cond Desc(32 char):

RAD LEVEL IN THE DRYWELL l

Analog / Digital:

A l

Ener Units / Dig States (12 char):

R/HR Ener Units Conversion (40 char):

l Minimum Instr Range (10 char):

IE2 Maximum Instr Ranee (10 char):

1E8 Zero Point Reference (G char):

N/A Reference Point Notes (40 char):

N/A PROC or SENS:

S l

Number of Sensors (3 char):

N/A l

How Processed (40 char):

N/A Sensor Locations (40 char):

DRYWELL. ELEV 282'. 2100 AZIh!OUTH Alarm / Trip Set Points (40 char):

ALERT @ 50 R/HR. HIGH @ 100 R/HR i

NI Detector Power Supply Cut.off N/A Power Level (15 char):

NI Detector Power Supply Turn-on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A Transmitters (Y or N, if No provide correction curve)):

Level Reference Leg (WET or DRY):

N/A Unique System Desc.(600 char):

ONE OF FOUR GAhthlA ION CHAh1BER SENSORS FOR THE PRIh1ARY CONTAINhlENT. h10NITORS GROSS RADIOACTIVITY PRESENT IN CONTAINh1ENT ATh10 SPHERE. SENSORS ARE LOCATED IN SEPERATE AREAS OF CONTAINh1ENT TO PROVIDE INDEPENDENT h1EASUREh1ENT AND TO VIEW LARGE FRACTIONS OF THE CONTAINh1ENT VOLUh1E.

l I

l l

\\

DPL AIM OF fs%

1 1

NRC DATA POINT LIBRARY REFERENCE FILE l Date:

I 12 / 18 / 91 l Reactor Unit (LM1 or LM2):

jLM1 Data Feeder:

lN/A NRC ERDS Parameter (12 char):

l DW RAD Point ID (12 char):

l 4RA191 Plant Spec Point Desc(40 char):

DRYWELL AREA POST LOCA Generic /Cond Desc(32 char):

RAD LEVEL IN THE DRYWELL Analog / Digital:

lA 1

Ener Units / Dig States (12 char):

I R/HR Ener Units Conversion (40 char):

l Minimum Instr Range (10 char):

lIE2 Maximum Instr Range (10 char):

l IE8 Zero Point Reference (6 char):

lN/A Reference Point Notes (40 char):

IN/A PROC or SENS:

IS Number of Sensors (3 char):

N/A How Processed (40 char):

N/A Sensor Locations (40 char):

DRYWELL. ELEVATION 272'.148u AZIMUTH Alarm / Trip Set Points (40 char):

ALERT @ 50 R/HR. HIGH @ 100 R/HR NI Detector Power Supply Cut off N/A Power Level (15 char):

NI Detector Power Supply Turn-on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A Transmitters (Y or N, if No provide correction curve)):

Level Reference Leg (WET or DRY):

N/A Unique System Desc.(600 char):

ONE OF FOUR GAMMA ION CHAMBER SENSORS FOR THE PRIMARY CONTAINMENT. MONITORS GROSS RADIOACTIVITY PRESENT IN CONTAINMENT ATMOSPHERE. SENSORS ARE LOCATED IN SEPERATE AREAS OF CONTAINMENT TO PROVIDE INDEPENDENT MEASUREMENT AND TO VIEW LARGE FRACTIONS OF THE CONTAINMENT VOLUME.

DPL 43M OF (15G5

I e

NRC DATA POINT LIBRARY REFERENCE FILE Date:

12 / 18 / 91 Reactor Unit (LM1 or LM2):

LM1 Data Feeder:

N/A l

NRC ERDS Parameter (12 char):

MN STEAM RAD l

Point id(12 char)

E1082 Plant Spec Point Dese(40 char):

MAIN STEAM RAD MON Generic /Cond Desc(32 char):

RAD LEVEL OF THE MAIN STEAM LINE l

Analog / Digital:

A Ener Units / Dig States (12 char):

MR/HR Ener Units Conversion (40 char):

LOG BASE 10 Minimum Instr Range (10 char):

1 Maximum Instr Range (10 char):

1.0E6 Zero Point Reference (6 char):

N/A l

Reference Point Notes (40 char):

N/A PROC or SENS:

S Number of Sensors (3 char):

N/A How Processed (40 char):

N/A Sensor Locations (40 char):

MN STM TUNNEL NEAR PRI CONTAINMENT Alarm / Trip Set Points (40 char):

HI@l.5xNFPB,HI HI@ 3XNFPB NI Detector Power Supply Cut-off N/A Power Level (15 char):

NI Detector Power Supply Turn-on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N

Transmitters (Y or N, if No provide correction curve)):

Level Reference Leg 6 VET or DRY):

N/A Unique System Desc.(600 char):

SCRAM @ 3 x NFPB. ONE OF FOUR MONITORS GAMMA RADIATION LEVEL EXTERIOR TO THE MAIN STEAM LINES DOWNSTREAM OF MAIN STEAM ISOLATION VALVES.

I i

9e89464eeeSede 9464ee9eeeGeGGGGe9 e l

DPL 4'lM OF fdGG

NRC DATA POINT LIBRARY REFERENCE FILE l

Date:

12 / 18 / 91 Reactor Unit (LM1 or LM2):

LMi Data Feeder:

N/A NRC ERDS Parameter (12 char):

DW PRESS Point ID (12 char):

E1425 Plant Spec Point Desc(40 char):

NARROW RANGE DRYWELL PRESS I

Generic /Cond Desc(32 char):

DRYWELL PRESSURE Analog / Digital:

A Ener Units / Die States (12 char):

PSIG Ener Units Conversion (40 char):

LINEAR i

Minimum Instr Rance(10 char):

5.0 Maximum Instr Rance(10 char):

5.0 Zero Point Reference (6 char):

N/A Reference Point Notes (40 char):

N/A PROC or SENS:

S Number of Sensors (3 char):

1 How Processed (40 char):

N/A Sensor Locations (40 char):

DRYWELL PRESSURE INSTRUMENTATION LINE Alarm / Trip Set Points (40 char):

HI @ 1.68 PSIG NI Detector Power Supply Cut-off N/A Power Level (15 char):

NI Detector Power Supply Turn on N/A Power Level (15 char).

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A Transmittere(Y or N, if No provide correction curve)):

Level Reference Leg (WET or DRY):

N/A Unique System Desc.(600 char):

SCRAM @ 1.68 PSIG. PRIMARY CONTAINMENT IS DESIGNED AND MAINTAINED FOR A MAXIMUM INTERNAL PRESSURE OF 55 PSIG.

DPL 1HG OF fd65

NRC DATA POINT LIBRARY REFERENCE FILE Date:

12 / 18 / 91 Reactor Unit (LM1 or LM2h LM1 Data Feeder:

N/A NRC ERDS Parameter (12 char):

DW PRESS Point ID (12 char):

E1423 Plant Spec Point Desc(40 chark WIDE RANGE DRYWELL PRESS B Generic /Cond Dese(32 char):

DRYWELL PRESSURE Analog / Digital:

A Ener Units / Dig States (12 char):

PSIG Ener Units Conversion (40 char):

LINEAR Minimum Instr Range (10 char):

-5.0 Maximum Instr Range (10 char):

165 Zero Point Reference (6 char):

N/A Reference Point Notes (40 char):

N/A P_ ROC or S_ ENS:

S Number of Sensors (3 char):

1

)

How Processed (40 char):

N/A Sensor Locations (40 charh DW PRESSURE INSTRUMENTATION LINE AlarmfTrip Set Points (40 char):

HIGH @ 1.68 PSIG NI Detector Power Supply Cut-off N/A Power Level (15 char):

NI Detector Power Supply Turn-on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A Transmitters (Y or N, if No provide correction curve)):

Level Reference Leg (WET or DP'-

N/A Unique System Desc.(600 char):

SCRAM @ 1.68 PSIG. PRIMARY CONTAINMENT IS DESIGNED AND MAINTAINED FOR A MAXIMUM INTERNAL PRESSURE OF 55 PSIG.

l l

DPL.45M OF 6565

NRC DATA POINT LIBRARY REFERENCE FILE Date:

12 / 18 / 91 Reactor Unit (LM1 or LM2):

LMi Data Feeder:

N/A NRC ERDS Parameter (12 char):

DW PRESS Point ID (12 char):

E1343 Plant Spec Point Desc(40 char):

WIDE RANGE DRYWELL PRESS A Generic /Cond Desc(32 char):

DRYWELL PRESS Analog / Digital:

A Ener Units / Dig States (12 char):

PSIG Ener Units Conversion (40 char):

LINEAR Minimum Instr Range (10 char):

5 Maximum Instr Range (10 char):

165 Zero Point Reference (6 char):

N/A Reference Point Notes (40 char):

N/A PROC or SENS:

S Number of Sensors (3 char):

1 How Processed (40 char):

N/A Sensor Locations (40 char):

STANDBY GAS TREATMENT LINE Alarm /I' rip Set Points (40 char):

HIGII@ 1.68 PSIG NI Detector Power Supply Cut.off N/A Power Level (15 char):

NI Detector Power Supply Turn on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N

Transmitters (Y or N, if No provide correction curve)):

Level Reference Leg (WET or DRY):

N/A Unique System Desc.(600 char):

SCRAM @ 1.68. PRIMARY CONTAINMENT IS DESIGNED AND MAINTAINED FOR A MAXIMUM INTERNAL PRESSURE OF 55 PSIC.

DPL ffRG OF fs64

l NRC DATA POINT LIBRARY REFERENCE FILE Date:

12 / 18 / 01 Reactor Unit (LM1 or LM2h LMi Data Feeder:

N/A NRC ERDS Parameter (12 charh DW TEMP Point ID (12 char):

E1515 Plant Spec Point Desc(40 char):

DRYWELL ATMOSPHERE TEMP Generic /Cond Desc(32 char):

DRYWELL TEMPERATURE Analog / Digital:

A Ener Units / Dig States (12 charh DEGF Ener Units Conversion (40 char):

QUADRATIC Minimum Instr Range (10 char):

0 Maximum Instr Ranee (10 char):

440 Zero Point Reference (3 char):

N/A Reference Point Notes (40 char):

N/A P_ ROC or SENS:

S Number of Sensors (3 chark i

How Processed (40 char):

N/A Sensor Locations (40 char):

DRYWELL Alarm / Trip Set Points (40 char):

HIGH @ 135 DEGF NI Detector Power Supply Cut-off N/A Power Level (15 char):

i NI Detector Power Supply Turn-on N/A Power Level (15 charh Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A Transmitters (Y or N, if No provide correction curve)h Level Reference Leg (WET or DRYh N/A Unique System Desc.(600 char):

PRIMARY CONTAINMENTIS DESIGNED AND MAINTAINED FOR A MAXIMUM INTERNAL TEMPERATURE OF 340 DEGF IN THE DRYWELL.

l t

4 eeeeceeeeeeeeseese eesese eeeeeoeee l

DPL EM OF fi&Gr>

\\

i NRC DATA POINT LIBRARY REFERENCE FILE t

Date:

i 03/20/9(...

Reactor Unit (LM1 or LM2):

I Lhil Data Feeder:

lN/A NRC ERDS Parameter (12 char):

l DW TEh1P Point ID (12 char):

IE1658 Plant Spec Point Desc(40 char):

DRYWELL ATh!OSPHERE TEh1P Generic /Cond Desc(32 char):

DRYWELL TEh1PERATURE Analog /D_ieital:

A Ener Units / Dig States (12 char):

DEGF Ener Units Conversion (40 char):

cubic Minimum Instr Range (10 char):

040 Maximum Instr Rance(10 char):

@D440 Zero Point Reference (6 char):

N/A Reference Point Notes (40 char):

l N/A PROC or SENS:

lS Number of Sensors (3 char):

1 How Processed (40 char):

N/A Sensor Locations (40 char):

DRYWELL Alarm /I' rip Set Points (40 char):

HIGH @l35 DEGF NI Detector Power Supply Cuteoff N/A Power Level (15 char):

1 NI Detector Power Supply Turn-on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A Transmitters (Y or N, if No provide correction curve)):

Level Reference Lee 6 VET or DRY):

N/A Unique System Desc.(600 char):

PRih1ARY CONTAINh1ENT IS DESIGNED AND htAINTAINED FOR A h1AXIh1Uh1 INTERNAL TEh1PERATURE OF 380 DEGF IN THE DRYWELL i

6 e

{

DPL @6 OF fd64 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee l

_ _ = _ -

NRC DATA POINT LIBRARY REFERENCE FILE f

Date:

12 / 18 / 01 Reactor Unit (LM1 or LM2):

LM1 Data Feeder:

N/A NRC ERDS Parameter (12 char):

SP TEMP Point ID (12 char):

E1424 Plant Spec Point Desc(40 char):

SUPPRESSION POOL TEMP B Generic /Cond Desc(32 char):

SUPPRESSION POOL TEMP Analog / Digital:

A Engr Units / Dig States (12 char):

DEGF Engr Units Conversion (40 char):

LINEAR Minimum Instr Range (10 char):

30 Maximum Instr Range (10 char):

1 230 Zero Point Reference (6 char):

N/A Reference Point Notes (40 char):

N/A P_ ROC or SENS:

IS Number of Sensors (3 char):

1 How Processed (40 char):

N/A Sensor Locations (40 char):

SUPPRESSION POOL AIR SPACE Alarm / Trip Set Points (40 char):

HIGH @ 95 DEGF NI Detector Power Supply Cut-off N/A Power Level (15 char):

NI Detector Power Supply Turn-on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N

Transmitters (Y or N, if No provide correction curve)):

Level Reference LegGVET or DRY):

N/A Unique System Desc.(600 char):

PRIMARY CONTAINMENT IS DESIGNED AND MAINTAINED FOR A MAXIMUM INTERNAL TEMPERATURE OF 220 DEGF IN THE SUPPRESSION POOL.

l DPL_@ GOF05GG

NRC DATA POINT LIBRARY REFERENCE FILE i

Date:

I 12 / 18 / 91 Reactor Unit (LM1 or LM2):

1LMi Data Feeder:

lN/A NRC ERDS Parameter (12 char):

1 SP TEMP Point ID (12 char):

}E1344 Plant Spec Point Desc(40 char):

I SUPPRESSION POOL TEMP A Generic /Cond Desc(32 char):

I SUPPRESSION POOL TEMP Analog /D_igital:

1A Ener Units / Die States (12 char):

I DEG F Ener Units Conversion (40 char):

I LINEAR Minimum Instr Range (10 char):

l 30 Maximum Instr Range (10 char):

1230 Zero Point Reference (6 char):

IN/A Reference Point Notes (40 char):

I N/A j

PROC or SENS:

IS Number of Sensors (3 char):

1 How Processed (40 char):

N/A

_ Sensor Locations (40 char):

SUPPRESSION POOL AIR SPACE Alarm / Trip Set Points (40 char):

HIGH @ 95 DEG F i

NI Detector Power Supply Cuteoff N/A Power Level (15 char):

NI Detector Power Supply Turnoon N/A Power Level (15 char):

1 Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A Transmitters (Y or N, if No provide correction curve)):

Level Reference Leg (WET or DRY): IN/A Unique System Desce(600 char):

PRIMARY CONTAINMENT IS DESIGNED AND MAINTAINED FOR A MAXIMUM INTERNAL TEMPERATURE OF 220 DEGF IN THE SUPPRESSION POOL l

4 SeeoeeeGeeeeeoeeeeseee eeeeee4446 DPL 5{MG OF fd65

~

NRC DATA POINT LIBRARY REFERENCE FILE f

Date:

12 / 18 / 91 Reactor l' nit (LM1 or LM2):

LM1 Data Feeder:

N/A NRC ERDS Parameter (12 char):

SP LEVEL Point ID (12 char):

E1680 Plant Spec Point Desc(40 char):

SUPP POOL LEVEL Generic /Cond Desc(32 char):

SUPP POOL WATER LEVEL Analog / Digital:

A Ener Units / Die States (12 char):

FT Ener Units Conversion (40 char):

LINEAR Minimum Instr Range (10 char):

20 Maximum Instr Range (10 char):

26 Zero Point Reference (6 char):

CNTFLR Reference Point Notes (40 char):

N/A PROC or SENS:

S Number of Sensors (3 char):

1 How Processed (40 char):

N/A Sensor Locations (40 char):

SUPP POOL LEVEL INSTRUMENT LINE Alarm / Trip Set Points (40 char):

LOW @22 FT. HIGH @24 FT 3 IN NI Detector Power Supply Cut-off N/A Power Level (15 char):

i NI Detector Power Supply Turn-on N/A I

Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N

Transmitters (Y or N, if No provide correction curve)):

Level Reference Leg (WET or DRY):

WET Unique System Desc.(600 char):

SUPPRESSION CHAMBER SPRAY HEADER @ 48.5 FT.

BO'ITOM OF SUPPRESSION CHAMBER VENT @ 39 FT.

SUPPRESSION TO DRYWELL VACUUM BREAKER Lr '3 OPENINO PRESSURE @ 39 FT. TOP OF HPCI O ".AUST @ 18 FT. SUPPRESSION POOL MINIMUM aTER REGION OF 122.120 CUBIC FT AND A MAXIMUM AIR REGION OF 159.540 CUBIC FT.

i I

Ge4G Ge GGGeGGG GG eeeee eGGGeee4eee ##

\\

DPL 11% OF fi365 l

NRC DATA POINT LIBRARY REFERENCE FILE Date:

l 12 / 18 ! 91 Reactor Unit Oil or LM2):

LM1 Data Feeder:

N/A NRC ERDS Parameter (12 char):

SP LEVEL Point ID (12 char):

E1602 Plant Spec Point Dese(40 char):

SUPP POOL LE\\TL Generic /Cond Dese(32 char):

SUPP POOL WATER LEVEL Analog /D_igital:

A Ener Units / Die States (12 char):

FT Ener Units Conversion (40 char):

LINEAR Minimum Instr Range (10 char):

20 Maximum Instr Range (10 char):

26 Zero Point Reference (6 char):

CNTFLR Reference Point Notes (40 char):

N/A PROC or SENS:

S Number of Sensors (3 char):

1 i

How Processed (40 char):

N/A Sensor Locations (40 char):

SUPP POOL LEVEL INSTRUMENT LINE Alarm / Trip Set Points (40 char):

LOW @22 FT. HIGH Ca24 FT 3 IN NI Detector Power Supply Cut-off N/A Power Level (15 char):

NI Detector Power Supply Turnoon N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N

Transmitters (Y or N, if No provide correction curve)):

Level Reference Leg (WET or DRY):

WET Unique System Desc.(600 char):

SUPPRESSION CHAMBER SPRAY HEADER @ 48.5 FT.

BOTI'OM OF SUPPRESSION CHAMBER VENT @ 39 FT.

SUPPRESSION TO DRYWELL VACUUM BREAKER LESS OPENING PRESSURE @ 39 FT. TOP OF HPCI EXHAUST @ 18 FT. SUPPRESSION POOL MINIMUM WATER REGION OF 122.120 CUBIC FT AND A MAXIMUM AIR REGION OF 159.5 40 CUBIC FT.

e eee e ceee eoeesee eeceeeeeeDeee e644 DPL 5246 OF fEG5

NRC DATA POINT LIBRARY REFERENCE FILE Date:

12 / 18 / 01 Reactor Unit (LM1 or LM2):

LMi Data Feeder:

N/A NRC ERDS Parameter (12 char):

SP LEVEL Point ID (12 char):

El18G Plant Spec Point Desc(40 char):

SUPP POOL LEVEL B Generic /Cond Desc(32 char):

SUPP POOL WATER LEVEL Analog / Digital:

A Engr Units / Die States (12 char):

FT Ener Units Conversion (40 char):

LINEAR Minimum Instr Range (10 char):

0 Maximum Instr Range (10 char):

50 Zero Point Reference (6 char):

CNTFLR Reference Point Notes (40 char):

N/A l

PROC or SENS:

S Number of Sensors (3 char):

1 How Processed (40 char):

N/A Sensor Locations (40 char):

SUPP POOL LEVEL INSTRUMENT LINE Alarm / Trip Set Points (40 char):

LOW @22 FT. HIGH @24 FT 3 IN NI Detector Power Supply Cut-off N/A Power Level (15 char):

NI Detector Power Supply Turn-on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N

Transmitters (Y or N, if No provide correction curve)):

Level Reference LeeGVET or DRY):

WET Unique System Desc.(600 char):

SUPPRESSION CHAMBER SPRAY HEADER @ 48.5 FT.

BOTI'OM OF SUPPRESSION CHAA1BER VENT @ 39 FT.

SUPPRESSION TO DRYWELL VACUUM BREAKER LESS OPENING PRESSURE @ 39 FT. TOP OF HPCI EXHAUST @ 18 FT. SUPPRESSION POOL MINIMUM WATER REGION OF 122,120 CUBIC FT AND A MAXIMUM AIR REGION OF 159.540 CUBIC FT.

l DPL MM OF fdGG

l NRC DATA POINT LIBRARY REFERENCE FILE Date:

l 12 /18 / 01 Reactor Unit (LM1 or LM2):

LM1 Data Feeder:

N/A NRC ERDS Parameter (12 char):

SP LEVEL Point ID (12 char):

E1210 Plant Spec Point Desc(40 char):

SUPP POOL LEVEL A Generic!Cond Desc(32 char):

SUPP POOL WATER LEVEL Analog / Digital:

A Engr Units / Dig States (12 char):

FT Ener Units Conversion (40 char):

LINEAR hhnunum Instr Range (10 char):

0 Maximum Instr Range (10 char):

50 Zero Point Reference (6 char):

CNTFLR Reference Point Notes (40 char):

N/A PROC or SENS:

S Number of Sensors (3 char):

1 How Processed (40 char):

N/A Sensor Locations (40 char):

SUPP POOL LEVEL INSTRUMENT LINE Alarmffrip Set Points (40 char):

LOW @22 FT, HIGH @24 FT 3 IN NI Detector Power Supply Cut-off N/A Power Level (15 char):

NI Detector Power Supply Turn-on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N

Transmitters (Y or N, if No provide correction curve)):

Level Reference Leg (WET or DRY):

WET Unique System Desc.(600 char):

SUPPRESSION CHAMBER SPRAY HEADER @ 48.5 FT.

BOTTOM OF SUPPRESSION CHAMBER VENT @ 3917.

SUPPRESSION TO DRYWELL VACUUM BREAKER LESS OPENING PRESSURE @ 39 FT. TOP OF HPCI EXHAUST @ 18 FT. SUPPRESSION POOL MINIMUM WATER REGION OF 122,120 CUBIC FT AND A MAXIMUM AIR REGION OF 159.540 CUBIC FT.

DPL 54M OF fi36G

NRC DATA POINT LIBRARY REFERENCE FILE Date:

12 / 18 / 91 Reactor Unit (LM1 or LM2):

LMi Data Feeder:

N/A NRC ERDS Parameter (12 char):

H2 CONC Point ID (12 char):

821V0065 Plant Spec Point Desc(40 char):

MAX H2 Generic /Cond Desc(32 char):

DRYWELL H2 CONCENTRATION Analog / Digital:

A Engr Units / Die States (12 char):

Ener Units Conversion (40 char):

LINEAR Minimum Instr Range (10 char):

0 Maximum Instr Range (10 char):

30 Zero Point Reference (6 char):

N/A Reference Point Notes (40 char):

N/A PROC or SENS:

P Number of Sensors (3 char):

2 How Processed (40 char):

MAX OF 2 SENSORS Sensor Locations (40 char):

SAMPLES FROM SUPPRESSION POOL OR DRYWELL Alarm / Trip Set Points (40 char):

HIGH @ 4%

NI Detector Power Supply Cut-off N/A Power Level (15 char):

NI Detector Power Supply Turn-on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A Transmitters (Y or N,if No provide correction curve)):

Level Reference Leg 6 VET or DRY):

N/A Unique System Desc.(600 char):

ONE OF TWO REDUNDANT SYSTEMS CAPABLE OF SAMPLING DRYWELL AND SUPPRESSION CHAMBER ATMOSPHERES. SAMPLES ARE TAKEN FROM DRYWELL. DRYWELL EXHAUST. SUPPRESSION POOL ATMOSPHERE AND SUPPRESSION POOL EXHAUST AND ARE RETURNED TO DRYWELL/ SUPPRESSION POOL.

l DPL 55% OF fi&65

NRC DATA POINT LIBRARY REFERENCE FILE Date:

12 / 18 / 91 i

Reactor Unit (LM1 or LM2):

LM1 Data Feeder:

N/A NRC ERDS Parameter (12 char):

H2 CONC Point ID (12 char):

82ivo064 Plant Spec Point Desc(40 char):

MAX O2 l

Generic /Cond Dese(32 char):

DRYWELL 02 CONCENTRATION l

Analog / Digital:

A Ener Units / Die States (12 char):

Ener Units Conversion (40 char):

LINEAR Minimum Instr Range (10 char):

0 Maximum Instr Range (10 char):

25 Zero Point Reference (6 char):

N/A Reference Point Notes (40 char):

N/A P_ ROC or SENS:

IP Number of Sensors (3 char):

2 How Processed (40 char):

MAX OF 2 SENSORS Sensor Locations (40 char):

SAMPLES FROM SUPPRESSION POOL OR DRBVELL Alarm / Trip Set Points (40 char):

HIGH @ 4%

l NI Detector Power Supply Cut.off N/A Power Level (15 char):

l NI Detector Power Supply Turn-on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A l

Transmitters (Y or N, if No provide correction curve)):

Level Reference Lee (WET or DRY):

N/A

)

Unique System Desc.(600 char):

ONE OF TWO REDUNDANT SYSTEMS CAPABLE OF SAMPLING DREVELL AND SUPPRESSION CHAMBER ATMOSPHERES. SAMPLES ARE TAKEN FROM DREVELL, DRYWELL EXHAUST. SUPPRESSION POOL ATMOSPHERE AND SUPPRESSION POOL EXHAUST AND ARE RETURNED TO DRYWELUSUPPRESSION POOL.

t DPL M M OFfFA

O NRC DATA POINT LIBRARY REFERENCE FILE Date:

12 / 18 / 91 Reactor Unit (LM1 or LM2):

LM1 Data Feeder:

N/A NRC ERDS Parameter (12 char):

CST LEVEL l Point ID (12 char):

E1083 i Plant Spec Point Dese(40 char):

CONDENSATE STORAGE LEVEL Generic /Cond Dese(32 char):

COND STORAGE TK LEVEL Analog /D_ieital:

A Ener Units / Dig States (12 char):

FT Ener Units Conversion (40 char):

LINEAR.

Minimum Instr Range (10 c1.ar):

0 Maximum Instr Range (10 char):

45 Zero Point Reference (6 char):

TNKBOT Reference Point Notes (40 char):

N/A PROC or SENS:

S Number of Sensors (3 char):

1 How Processed (40 char):

N/A Sensor Locations (40 char):

CST Alarm / Trip Set Points (40 char):

HIGH @ 128 FT 1 IN NI Detector Power Supply Cut-off N/A Power Level (15 char):

NI Detector Power Supply Turn-on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A Transmitters (Y or N, if No provide correction curve)):

Level Reference Lee 6 VET or DRY):

N/A l

Unique System Desc.(600 char):

CST CAPACITY IS 200,000 GAL.

l DPL SIM OF {i54

i NRC DATA POINT LIBRARY REFERENCE FILE

_Date:

1 12/18/91 Reactor Unit (LM1 or LM2):

}LM1 Data Feeder:

IN/A NRC ERDS Parameter (12 char):

WIND SPEED Point ID (12 char):

T1.SP.1 Plant Spec Point Desc(40 char):

TOWER 1 WIND SPEED Generic /Cond Desc(32 char):

WIND SPEED AT REACTOR SITE Analog / Digital:

A Ener Units / Dig States (12 char):

MPH Ener Units Conversion (40 char):

LINEAR Minimum Instr Range (10 char):

0 Maximum Instr Range (10 char):

100 Zero Point Reference (6 char):

N/A Reference Point Notes (40 char):

N/A PROC or SENS:

IS Number of Sensors (3 char):

1 How Processed (40 char):

N/A Sensor Locations (40 chari:

ELEVATION 425' MSL Alarm / Trip Set Points (40 char):

N/A NI Deteex: Power Supply Cut-off N/A Powc r Level (15 char):

NI Detector Power Supply Turn-on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A Transmitters (Y or N, if No provide correction curve)):

Level Reference Leg (WET or DRY): IN/A Unique System Desc.(600 char):

TOWER 1 IS A 280' TOWER SITUATED APPROX 3000' NW OF THE LGS STRUCTURE VENTS. GRADE j

1 ELEVATION IS 250' M3L. USED AS PRIMARY INDICATION OF SITE WIND SPEED i

DPL BM OF @

NRC DATA POINT LIBRARY REFERENCE FILE Date:

12/ 18 / 01 Reactor Unit (LM1 or LM2):

LM1 Data Feeder:

N/A NRC ERDS Parameter (12 char):

WIND SPEED Point ID fi2 char):

T2.SP.U Plant Spec Point Desc(40 char):

TOWER 2 WIND SPEED Generic /Cond Desc(32 char):

WIND SPEED AT REACTOR SITE Analog / Digital:

A Ener Units / Die States (12 char):

MPH Ener Units Conversion (40 char):

LINEAR Minimum Instr Range (10 char):

0 Maximum Instr Range (10 char):

100 ZercZeira Reference (6 char):

N/A Reference Point Notes (40 char):

N/A PROC or SENS:

S Number of Sensors (3 char):

1 How Processed (40 char):

N/A Sensor Locations (40 char):

ELEVN1;ON 425' MSL Alarm / Trip Set Points (40 char):

N/A NI Detector Power Supply Cut-off N/A Power Level (15 char):

NI Detector Power Supply Turn-on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A Transmitters (Y or N,if No provide correction curve)):

Level Reference Leg 6 VET or DRY):

N/A Unique System Desc.(600 char):

TOWER 2 IS A 310' TOWER SITUATED APPROX 2100' WEST OF THE LGS STRUCTURE VENTS. GRADE ELEVATION IS 121' MSL. USED AS SECONDARY INDICATION OF SITE WIND SPEED l

DPL DM OF ry

NRC DATA POINT LIBRARY REFERENCE FILE l

Date:

12 / 18 / 91

^

Reactor Unit (LM1 or LM2):

LM1 Data Feeder:

N/A NRC ERDS Parameter (12 char):

WIND DIR Point ID (12 char):

T 1. D R.I Plant Spec Point Desc(40 char):

TOWER 1 DIRECTION Generic /Cond Desc(32 char):

WIND DIR AT REACTOR SITE Analog /D_igital:

A Ener Units / Die States (12 char):

DEGREES Ener Units Conversion (40 char):

LINEAR Minimum Instr Range (10 char):

0 Manmum Instr Ranee (10 char):

540 Zero Point Reference (6 char):

N/A Reference Point Notes (40 char):

N/A PROC or SENS:

S Number of Sensors (3 char):

1 How Processed (40 char):

N/A Sensor Locations (40 char):

N/A Alarm / Trip Set Points (40 char):

N/A NI Detector Power Supply Cut-off N/A Power Level (15 char):

NI Detector Power Supply Turn-on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A Transmitters (Y or N,if No provide correction curve)):

Level Reference Lee (WET or DRY):

N/A Unique System Desc.(600 char):

TOWER 1 IS A 280' FOWER SITUATED APPROX 3000' NW OF THE LGS STRUCTURE VENTS. GRADE ELEVATION IS 250' MSL. USED AS PRIMARY INDICATION OF WIND DIRECTION. Wind direction is measured from direction of wind.

DPL faM OF fit /,~,

NRC DATA POINT LIBRARY REFERENCE FILE Date:

12 / 18 / 91 Reactor Unit (LM1 or LM2):

LM1 Data Feeder:

N/A NRC ERDS Parameter (12 char):

WIND DIR Point ID (12 char):

T2.DR.U Plant Spec Point Desc(40 char):

TOWER 2 DIRECTION Generic /Cond Desc(32 char):

WIND DIR AT REACTOR SITE Analog / Digital:

A Ener Units / Dig States (12 char):

DEGREES Ener Units Conversion (40 char):

LINEAR Minimum Instr Range (10 char):

0 Maximum Instr Range (10 char):

540 Zero Point Reference (6 char):

N/A Reference Point Notes (40 char):

N/A PROC or SENS:

S Number of Sensors (3 char):

1 How Processed (40 char):

N/A Sensor Locations (40 char):

N/A Alarm / Trip Set Points (40 char):

LINEAR NI Detector Power Supply Cut-off N/A Power Level (15 char):

NI Detector Power Supply Turn-on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A Transmitters (Y or N,if No provide correction curve)):

l Level Reference Leg (WET or DRY):

N/A Unique System Desc.(600 char):

TOWER 2 IS A 310' TOWER SITUATED APPROX 2100' WEST OF THE LCS STRUCTURE VENTS. GRADE ELEVATION IS 121' MSL. USED AS SECONDARY INDICATION OF WIND DIRECTION. Wind direction is measured from direction of wind.

i l

DPL G1M OF ff/4 i

1

NRC DATA POINT LIBRARY REFERENCE FILE l

l

~

Date:

12/ 18 / 91 Reactor Unit (Illi or IA12):

LM1 l

Data Feeder:

N/A NRC ERDS ParametA(12 char):

STAB CLAS Point ID (12 char):

T1.DT.UL Plant Spec Point Desc(40' char)-

TOWER 1 DELTA. TEMP

~

Generic /Cond Desc(32 char):

AIR STABILITY AT THE REACTOR SITE

~

Analoe/ Digital:

A Enstr Units / Dig States (12 char):

DEGF Ener Units Conversion (40 char):

03 EAR I

Muun um Instr Range (10 char):

0

~~~

Maximum Instr Range (10 char):

100 Zero Point Reference (6 char):

N/A Reference Point Notes (40 char):

N/A PROC or SENS:

P Number of Sensors (3 char):

2 How Processed (40 char):

DIFFERENCE Sensor Locations (40 char):

N/A

~

Alarm / Trip Set Points (40 char):

LINEAR NI Detector Power Supply Cut-off N/A Power Level (15 char):

l NI Detector Power Supply Turn-on N/A Power Level (15 char):

l Instrument Failure Mode (3,Qchu):

N/A

~

t Temperature Compensation for DP N/A j

Transmitters (Y or N,if No provide correction curve)):

Level Reference Leg (WET or DRY):

N/A l

Unique System Desc.(600 char):

TOWER 1 IS A 280' TOWER S!TUATED APPROX 3000' NW OF THE LGS STRUCTURE VENTS. GRADE ELEVATION IS 250' MSL. THIS VALUE IS THE UPPER TOWER TEMPERATURE MINUS THE LOWER TOWER TEMPERATURE. USED AS PRIMARY INDICATION OF DELTA TEMPERATURE.

i DPL 62M OF EM l

l

\\

l l

s NRC DATA POINT LIBRARY REFERENCE FILE Date:

12 / 18/ 91 Reactor Unit (LM1 or LM2):

LM1 Data Feeder:

N/A NRC ERDS Parameter (12 char):

STAB CLAS Point ID (12 char):

T2.DT.UL Plant Spec Point Desc(40 chark TOWER 2 DELTA. TEMP Generic /Cond Desc(32 char):

AIR STABILITY AT THE REACTOR SITE Analog /D_igital:

A Ener Units / Die States (12 char):

DEGF Engr Units Conversion (40 char):

LINEAR Minimum Instr Range (10 char):

0 Maximum Instr Range (10 char):

100 Zero Point Reference (6 char):

N/A Reference Point Notes (40 char):

N/A PROC or S_ ENS:

P Number of Sensors (3 char):

2 How Processed (40 char):

DIFFERENCE Sensor Locations (40 char):

N/A Alarm / Trip Set Points (40 char):

LINEAR NI Detector Power Supply Cut-off N/A i

Power Level (15 char):

NI Detector Power Supply Turn-on N/A Power Level (15 char):

l Instrument Failure Mode (30 charh N/A Temperature Compensation for DP N/A Transmitters (Y or N, if No provide correction curve)):

Level Reference Lee (WET or DRY):

N/A Unique System Desc.(600 char):

TOWER 2 IS A 310' TOWER SITUATED APPROX 2100' l

WEST OF THE LGS STRUCTURE VENTS. GRADE l

ELEVATION IS 121' MSL. THIS VALUE IS THE UPPER TOWER TEMPERATURE MINUS THE LOWER TOWER l

TEMPERATURE. USED AS SECONDARY INDICATION l

OF DELTA TEMPERATURE.

1 l

f I

l DPL @ 6OFfEA

.l

~

c.

NRC DATA POINT LIBRARY REFERENCE FILE Date:

12/ 18/91 Reactor Unit (LM1 or LM2):

LM1 Data Feeder:

N/A NPsC ERDS Parameter (12 char):

STAB CLAS Point ID (12 char):

T1.ST.I Plant Spec Point Desc(40 char):

TOWER 1 SIGMA THETA i

Generic /Cond Dese(32 char):

AIR STABILnT AT THE REACTOR SITE Analog / Digital:

A Ener Units / Dig States (12 char):

DEG Ener Units Conversion (40 char):

LINEAR Muumum Instr Range (10 char):

0 Maximum Instr Range (10 char):

360 Zero Point Reference (6 char):

N/A Reference Point Notes (40 char):

N/A PROC or SENS:

P Number of Sensors (3 char):

2 How Processed (40 char):

STD DEV OF HORIZONTAL WIND DIR Sensor Locations (40 char):

N/A Alarm / Trip Set Points (40 char):

LINEAR NI Detector Power Supply Cut.off N/A Power Level (15 char):

NI Detector Power Supply Turn.on N/A Power Level (15 char):

Instrument Failure Mode (30 char):

N/A Temperature Compensation for DP N/A 1

Transmitter.3(Y or N,if No provide correction curve)):

Level Reference Lee (WET or DRY):

N/A Unique System Desc.(600 char):

TOWER 1 IS A 280' TOWER SITUATED APPPOX 3000' l

NW OF THE LGS STRUCTURE VENTS. GRADE ELEVATION IS 250' MSL. THIS VALUE IS A CALCULATED VALUE. USED AS PRIMARY INDICATION OF SIGMA THETA.

]

DPL fliM OF MM i

s

l w

NRC DATA POINT LIBRARY REFERENCE FILE Date:

12/ 18 /91 Reactor Unit (LM1 or LM2):

LM1 Data Feeder:

N/A NRC ERDS Parameter (12 char):

STAB CLAS Point ID (12 char):

T2.ST.I Plant Spec Point Desc(40 char):

TOWER 2 SIGMA THETA Generic /Cond Desc(32 char):

AIR STABILITY AT THE REACTOR SITE Analog /D_igital:

A Ener Units / Die States (12 char):

DEG Engr Units Conversion (40 char):

LINEAR Minimum Instr Range (10 char):

0 Maximum Instr Range (10 char):

360 Zero Point Reference (6 char):

N/A Reference Point Notes (40 char):

N/A PROC or SENS:

P Number of Sensors (3 char):

2 How Processed (40 char):

STD DEV OF. HORIZONTAL WIND DIR Sensor Locations (40 char):

N/A Alarm / Trip Set Points (40 char):

LINEAR NI Detector Power Supply Cut-off N/A Power Level (15 char):

NI Detector Power Supply Turn-on N/A Power Level (15 char).

Instrument Failure Mode (30 char):

N/A Temperature Corrpensation for DP N/A Transmitters (Y or N, if No provide correction curve)):

Level Reference Leg (WET or DRY):

N/A Unique System Desc.(600 cha.-):

TOWER 2 IS A 310' TOWER SITUATED APPROX 2100' NW OF THF LCS STRUCTURE VENTS. GRADE ZLEVATION IS 121' MSL. THIS VALUE IS A CALCULATED VALUE. USED AS SECONDARY INDICATION OF SIGMA THETA.

..........~.....................