__

TABLE 3 SOLID WASTE & IRRADIATED FUEL SHIPMENTS QUARTERS 3 & 4, 1989 A.

SOLID WASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL (DOES NOT INCLUDE IRRADIATED FUEL)

TYPE OF WASTE 6-MONTH EST. TOTAL PERIOD ERROR (%)

a.

Spent resins, filter sludges

59. 4 la 125%

evaporator bottoms, etc.

2.09E+02 Ci Percent Abuncance Curies Fe-55 40.6%

8.49E+01 Co-60 27.7%

5.79E+01 Ni-63 14.4%

3.01E+01 Co-58 5.3%

1.11E+01 Cs-137 4.0%

8.36E+00 H-3 1.9%

3.97E+00 Cs-134 1.8%

3.76E+00 Mu-54 1.3%

2.72E+00 Nb-95 1.0%

2.09E400 3

b.

Dry compressible waste, 102.7 m 25%

contaminated equipment, etc.

6.40E+00 Ci Fe-55 50.2%

3.21E+00 Co-58 19.3%

1.24E+00 Co-60 14.3%

9.15E-01 Ni-63 4.7%

3.01E-01 Mn-54 3.7%

2.37E-01 C-14' 2.6%

1.66E-01 Nb-95 1.8%

1.15E-01 Zr-95 1.5%

9.60E-02 l

Cr-51 1.5%

9.60E-02 c.

Irradiated components, control 0m rods, etc.

O Ci 3

d.

Other 0m 0 Ci Page 13 Rev.

5/92 l

9205180265 920515 PDR ADOCK 05000483 R

PDR

.