Discusses 840710 Telcon Between D Fieno & W Mcdowell Re Spent Fuel Pool Two Region Rerack Mods.Util Commits to Physical Blocks in Nonfuel Locations During Checkerboard Storage
ML20090F307
Person / Time
Site: McGuire, Mcguire  
Issue date: 07/16/1984
From: Tucker H
DUKE POWER CO.
To: Adensam E, Harold Denton
Office of Nuclear Reactor Regulation
References
TAC-53531, TAC-53532, NUDOCS 8407200241
Download: ML20090F307 (1)


Text

- _.

DUKE POWER GOMPANY P.O. HOX 33180 CHAHLOTTE, N.O. 28242

-HALU. TUCKER Tetepuoxe va.;s emenroewt (704) 373-4531 July 16, 1984

=r-

Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation U. S. Nuclear. Regulatory Commission Washington, D. C.

20555

-Attention:

Ms. E. G. Adensam, Chief Licensing Branch No. 4 Re: McGuire Nuclear Station Docket Nos. 50-369, 50-370

Dear Mr. Denton:

This letter is in reference to a July 10, 1984 telephone ~ conversation between Dan Fieno, NRC/0NRR, and W. H. McDowell, Duke Power Company / Licensing, concerning the McGuire Nuclear Station spent fuel pool two region rerack modifications.

. Duke Power Company intends and expects to utilize only Region 1 locations for storage of unqualified fuel assemblies, i.e.

fuel assemblies which do not meet

the burnup criteria for Region 2 storage. However, in the-unlikely event that all Region 2 spaces are filled and storage of other unqualified fuel

. at:semblies is needed, a checkerboard storage configuration will be utilized in Region 2 for etorage of the unqualified assemblies.

The NRC had requested Duke Power to commit to physical blocks in the non-fuel locations during checkerboard storage.

Initially Duke Power did not commit to this based on reasons described in a June 7, 1984 letter to H. R. Denton, NRC, from H. B. Tucker, Duke Power Company. In the July 10, 1984 telephone conversation, Dan Fieno stated the NRC's position on this topic and again requested that Duke Power commit to the physical blockage of non-fuel locations.

During this telephone conversation, W. H. McDowell agreed that Duke Power would commit to this restriction.

Please contact us if there are further questions regarding this matter.

Very truly yours, l

l

~Hal B. Tucker WHM/rhs cc.

Mr. J. P. O'Reilly, Regional Administrator Mr. W. T. Orders U. S. Nuclear Regulatory Commission Senior Resident Inspector Suite 2900 McGuire Nuclear Station 101 Marietta Street, NW 0I Atlanta, Georgia 30323

/

8407200241 840716 (0

DRADOCK05000g D

i