OPERATING DATA REPORT DOCKET NO. 50-220 DATE 7/3/84 CO\\tPLETED BY

".W.

Roman TELEPHONE L515)349-2422 OPERATING STATUS

1. Unit Name:

Nine Mile Point Unit #1 Notes

2. Reporting Period:

6/1/84 thru 6/30/84 1850

3. Licensed Thermal Power (MWt):

640

4. Nameplate Rating (Gross MWe):

030

5. Design Electrical Rating (Net MWe):

620

6. Maximum Dependable Capacity (Gross MWe):

610

7. Maximum Dependable Capacity (Net MWe):
8. If Changes Occur in Capacity Ratings (Items Number 3 Through 7) Since Last Report. Give Reasons:
9. Power Level To Which Restricted.lf Any(Net MWe):
10. Reasons For Restrictions.lf Ar.y:

This Month Yr..to.Date Cumulatise i1. Hours in Reporting Period 720.0 4368.0 129,648.0

12. Number Of Hours Reactor Was Critical 252.5 2081.0 88382.7
13. Reactor Reserve Shutdown Hours 0

0 1204.2

14. Hours Generator On.Line 193.0 2018.5 85506.8
15. Unit Reserve Shutdown Hours 0

0 20.4

16. Gross Thermal Energy Generated (MWH) 276249.0 3,338,771.0 141,433,211.0
17. Gross Electrical Energy Generated (MWH) 89114*U 1,123,398.0 40,idd,1/9.0
18. Net Electrical Energy Generated (MWH)-

86.220.0 1,088,143.0 45,282,902.0

19. Unit Service Factor 26.8 39.5 66.0
20. Unit Availability Factor 26.8 39.5 66.0
21. Unit Capacity Factor IUsing MDC Net) 19*D 34*U 57.3
22. Unit Capacity Factor (Using DER Net) 19.3 34.3 56.3
23. Unit Forced Outage Rate 0.0 0.0 17.0
24. Shutdowns Scheduled Over Next 6 Months (Type.Date,and Duration of Each):
25. If Shut Down At End Of Report Period. Estimated Date of Startup:
26. Units in Test Status (Prior to Commercial Operation):

Forecast

. Achiesed INITIAL CRITICALITY INITIAL ELECTRICITY COMMERCIAL OPER AllON i

&l 8407200108 840630 l

PDRADOCKOS000gDR 20 i

R I"l77 '

4_j u

i AVER AGE D AILY UNIT POh ER LEVEL DOCKET NO. 50-220 g3,7 9 hfile Pt. Unit #1 DATE 7/3/84 CO'.le'LETED !!Y T.W. Roman TELEPilONE (315)349-2422 MONTH Junc.1984 DAY

}

AVERAGE DAILY POWER LEVEL, DAY AVERAGE DAILY POWER LEVEL (MWe Net)

(MWe Net!

1 0

g7 0

I-S 0

,S 0

3

'O 19 0

4 20 0

i 5

0 21 0

l 6

0 2

i 7

0

,3 gg 8

24 294 h

0 9

418,

33 i

j 10 0

26 534 il 0

2-444 q'

12 0

2s 600 33 0

29 607 f

14 0

30 606 35 0

31 16 0

1 l

1 INSTRUCTIONS l

lbl1IUffDJl.Illt the average daily unit pow'er lgggj in MWe.Ngg (og gagh g3F IH lbs ICP"'Ilh Hl'8Hfh.Cielupute10 l e flearest whole rnegawsts.

ep I

(9177) t 6

s ef UNITSHUTDOVNS AND POWER REDUCTIONS DOCKET NO.

50-220 UNIT NAME mfP* 1 4

G7 DATE 7/3/84 q

REPORTMONT11 June 1984 COMPLETED BY Tu unmnn XI TELEPHONE (315)349-2422 e.

's r 5 E

=

c.

i.

5}

j 753 LI""5

5%

$*?

Cause & Currective u

s,-

93,

.iE 5 a:

Event sT g

Action to 2:

c$ E E

j di g Report a

<E 0 yC Prevent Recurrence c5 8401 840317 2349.5 C

1 Unit shutdown for biennial refuel and overhaul 8402 840614 S

23 A

1 Electromatic 112 and 121 stuck open; Electromatic 113 did not open 8403 840617 S

115.5 A

1 Electromatic 121 stuck open; Electromatic 112, 113, and 123 leaked after test 8404 840622 S

3.5 B

Generator sequential trip test 8405 840623 S

.5 B

1 Turbine overspeed trip test

8406, 840627 F

8 A

Load reduction to 36% power because of fire on #13 feedwater pump I

2 3

4 F: Forced Reason:

Method:

Exhibit G -Instructions S: Scheduled A-Equipment Failure (Explain) 1 Manual for Preparation of Data B-Maintenance of Test 2-Manual Scrarn.

Entry Sheets for Licensee C-Refueling 3-Automatic Scram-Event Report (LER) File (NUREG-D-Regulatory Restriction 44ther (Explain) 0161)

E4perator Training & License Exam,ination F-Administrative 5

r G-Operational Error (Explain)

Exhibit 1 - Same Source 19/77)

Il-Other (Explain)

1 NIAGARA M0llAWK POWER CORPORATION NINE MILE POINT NUCLEAR STATION UNIT #1 NARRATIVE OF OPERATING EXPERIENCE JUNE 1984 Nine Mile Point Unit #1 returned to service from a major refueling and overhaul outage during the month of June. The station operated with a monthly availability factor of 28.6% and a net design cicctrical rating capacity factor of 19.3%.

Capacity / Availability losses were due to the foJ10 wing:

The station was shutdown for a planned refueling up to June 13th when the first reactor start up was. commenced.

The plant was shut down due to electromatic relief valve test failures. A second reactor start-up was commenced on June 16th and relief valve failures again forced a plant shutdown. A third reactor startup was commenced on June 22nd.

The Turbine / Generator was placed on line at 0500 June 23rd after two Turbine /

Generator trip tests.

The plant operated normally reaching top load on June 27th. Smoldering insulation on the #13 shaft driven feedwater pump caused a load reduction to 36% power at 0430 on the 27th'.

The plant returned to full load again on the 28th and operated normally the rest of the month.

k d

w-w-+

1 p

-v-a y

w-var 9

= e

r CLASS I WORK - h!ECilANICAL 61AINTENANCE - JUNE 1984 hR# 25247

  1. 111 Cont. Spray Raw Water Pump - Rebuilt-WR# 27072
  1. 11 Emerg. Cooling LCV-60-17, cleaned and repacked hR#- 25210 201.2-537 Post LOCA BV, replaced temp packing hR# 27057
  1. 11 Rx. Bldg. IIcat Exchanger, opened, cleaned, installed new gaskets hR# 25209 42.1R-1 6 R-2 Liquid Poison, installed U-bolts hR#' 24633
  1. 121 Cont. Spray Raw Water Pump, replaced pump hR# 27015 CRD llCU 18-27, replaced piston seals and 0 rings, rebuilt and installed hR# 26772 Emerg. Cooling llanger 39-1122, readjusted spring can hangers hR# 27000 blanual Valves 80, 90 6 91, took up on packings WR# 25197-liyd. Water Chem, blonitor Taps CS-G-3, New valve 6 Nipple installed hR# 27161 CRD Filter #11, replaced dirty filters and 0 rings and gasket hR# 27058 RBCLC #12 70-14, cleaned tubes, tested installed new gaskets hR# 27177 CRD 18-07 106 Valve, polished seat, reinstalled all parts and packing hR# 22419 94-30 Instr. Air dryer, replaced filters WR# 23450
  1. 13 Recire pp; #13 Closed Loop Cooling BV, cleaned springs and stem hR#

27059

  1. 13 RBCLE Ileat Exchanger; cicaned covers, cleaned tubes, press, tested hR# 26262 18-03 CRD; uncoupled drive hR# 21298 1984 outage hydro; took up on packings, flange Icais.

WR# 27194 DW Cooler 70-126, 130; replaced springs hR# 21429 X-154 6 X-9 Pentrations - Welded nipples into couplings hR# 26778 66-ilS-9 Snubber; filled reservior to proper level WR# 21210 Emerg. Cond. AC IV Valve 39-10; replaced stem new gaskets, new packing hR# 27192

  1. 12 FW Pump; replaced gasket on gear box hR# 27191
  1. 11 FW Pump; replaced gasket on gear box ht# 26568
  1. 12 Emerg. Cond. LCV 60-18; removed bonnet, cleaned seats, replaced gasket WR# 24167 Inst. Air Blocking Valve 94-35; drilled out broken plug, replaced internals hR# 27232 CRD 46-31 Accumulator; overhauled tank, rebuilt WR# 24583 Cond. Demin. Strainers B11-16; checked all strainers hR# 27402
  1. 121 Electromatic Relief Valve; installed pilot valve hR# 27413
  1. 122 Electromatic Relief Valve; installed pilot valve Cond Pump; repacked 50-01, #11 WR# 27412
  1. 123 Electromatic Relief Valve; Cleaned Valve, tightened union, checked WR# 27414 pilot setting
  1. 112 Electromatic Relief Valve; Cleaned Valve, tightened union, checked hR# 27401 pilot setting WR# 27475
  1. 122 Cont. Spray Disch. Isol. Valve; Cleaned stem and repacked
  1. 01-112 Electromatic #112; disassembled, cicaned and lapped parts hR# 27424 01-NR-108F #123 Electromatic; disassembled, cicaned and lapped parts hR# 27429 01-121 Electromatic #121; disassembled, cleaned and lapped parts hR# 27425 01-NR-108D #122 Electromatir; disassembled, cleaned and lapped parts hR# 27427 01-NR-108A #111 Electromatic; disassembled, cleaned and lapped parts WR# 27430 01-NR-108E #113 Electromatic; disassembled, cleaned and lapped parts WR# 07428

CLASS I WORK ~- INSTRUMENT 6 CONTROL - JUNE 1984 WR#: 27037 Isolation Valve 93-13; E/P converter leaking air (repaired tubing 6. fittings)

WR# 27681 Test Circuits.for MSIV 7% closure-(cleaned and adjusted vent valves)

s CLASS I M.O.'ELEC. MAINT.

4401

' Motor Operated Valve 38-02 Cable Replacement 3411 Core Spray /Rx Head Vent Valve Logic 2131

'Rx Protection System M.G. Set Alarms 3405 Remote Shutdown-Panel Isolation 3938-FW/HPCI Cont. Sys., Low Flow Control 2440 Containment _ Vent Sys-Post LOCA

. _ ~ - - -

~.

~. - _-.

4 i

COMPLETED ELECTRICAL MAINTENANCE CLASS 1 SAFETY RELATED WR'S - JUNE l

WRf

'26890 Valves 68-01 & 68 tightened bolts on micro switches i

along with all associated conduit & flex fittings WRf 26889 Rx press xmitters 36-31, 36-32, & 36 replaced flex conduit to xmitters WRd 27073 12K23 Rx level High Trip relay - replaced relay I

WR# 27076 DW nitrogen make up - replaced light bulb WR# 27077 Torus N2 make up - operated valve no problem found l

WRf 27074 Cont Spr to Wst IVII - adjusted by - pass switch.

WRf 27080 68-04 Valve - traced grounded wire to splice box retaped connection WR# 21587 MG 171 83 Relay - cleaned contacts F

WR# 27079 167 MG set under frequency relay 81LX - replaced defective Agastat WR# 26886 BV93 installed motor terminal strip WR# 21588 Relay 83 on MG set 161 - Burnished contacts WRd 27025 Torus air vent & isolation Valve 11 - stroked valve and lights worked properly

{

WRf 26986 Shutdown cooling IV38 replaced motor & drive gear, replaced grease in operator housing, replaced spring pins in manual declutch shaft WRf 26985 Reactor shutdown cooling IV 38 changed close torque setting from 2.5 to 2.25 as per Movats report WRf 27172 Main steam isolation valves - reset open & close valve position limit switches WRf 27169 Drywell CAM IV for return line - restored wiring per leads l

lifted log entry 1770.

~

WRf 27173 39-10 emergency condenser cond return IV - replaced valve i

stem i

WRf 27222 Drywell flooding block valve - replaced cap screws, checked limitorque operator & lubricated sten l

WRf 27260

  1. 11 FW Pump FCV Hi level trip limit switches - adjusted l

limit switches l

WR# 27404 Electromatic relief valve 113 - replaced fuse relocated wires and operated solenoid WRf 26989 Electromatic relief valves 121, 122, 123, 112, 111 & 113 -

' cleaned all solenoid armatures & freed all movable parts WRf 27209 Core spray vent IV 121 - tightened control fuse connector I

WRf 27039 12 Cond Domin inlet valve limit switch - adjusted limit switch i

WRd 27437 122 containment Spray IV - replaced solenoid coil

i NMP-8941

_~?

4 NIAGARA MOHAWK POWER CORPORATION NIAGARA MOHAWK 300 ERIE BOULEVARD. WEST SYRACUSE, N. Y.14202 July 13,1984 Director

' Office of Inspection and Enforcement U.S. Nuclear Regulatory Corraission Washington, DC 20555 Attn:

Document and Control Desk Re:

Docke.t No. 50-220 DPR-63

Dear Sir:

Submitted hereicith is the Report af Operating Statistics and Shatdown for June 1984 for the Mine Mile Point Nuelcar Station Unit #1.

Also included is a narrative report of Operating Experience for June 1984.

Veru thaty yours, Ad.

ff Thomas E. Lempges Vice President Nuclear Generation TEL/Lo I

attachments ces Director, 0ffice of 18E (lO copies) 56,3<

l a