f l

O Exhibit B Prairie Island Nuclear Generating Plant License Amendment Request dated July 9,1984 Proposed changes to the Technical Specifications of Appendix A of Operating Licenses DPR-42 and 60.

Exhibit B consists of revised pages of Appendix A Technical Specifications as listed below:

Pages TS.4.12-5 8407180236 840709 PDR ADOCK 05000282 PDR p

I

/

TS.4.12-5 REV

2. The steam generator shall be determined OPERABLE after completing the corresponding actions (plug all tubes exceeding the plugging limit and all tubes containing through-wall cracks) required by Table TS.4.12-1.*

l E.

Reports

1. Following each in-service inspection of steam generator tubes, if there are any tubes requiring plugging, the number of tubes plugged in each steam generator shall be i

reported to the Commission within 15 days.

2. Results of steam generator tube inspections which fall into Category C-3 require notification to the Commission prior to resumption of plant operation, and reporting as a Reportable Occurrence with prompt notification with written followup. The written followup of this report shall provide a description of investigations conducted to determine cause of the tube degradation and corrective measures taken to prevent recurrence.

~

- ___ - ____ _ _ _ _ _ - _ _ _ _