Proposed Tech Specs Re Steam Generator Operability
ML20090D415
Person / Time
Site: Prairie Island  Xcel Energy icon.png
Issue date: 07/09/1984
From:
NORTHERN STATES POWER CO.
To:
Shared Package
ML20090D408 List:
References
TAC-55237, NUDOCS 8407180236
Download: ML20090D415 (2)


Text

f l . O Exhibit B Prairie Island Nuclear Generating Plant License Amendment Request dated July 9,1984 Proposed changes to the Technical Specifications of Appendix A of Operating Licenses DPR-42 and 60.

Exhibit B consists of revised pages of Appendix A Technical Specifications as listed below:

Pages TS.4.12-5 8407180236 840709 PDR ADOCK 05000282 PDR p

I / TS.4.12-5 REV

2. The steam generator shall be determined OPERABLE after completing the corresponding actions (plug all tubes exceeding the plugging limit and all tubes containing through-wall cracks) required by Table TS.4.12-1.* l E. Reports
1. Following each in-service inspection of steam generator tubes, if there are any tubes requiring plugging, the number of tubes plugged in each steam generator shall be i reported to the Commission within 15 days.
2. Results of steam generator tube inspections which fall into Category C-3 require notification to the Commission prior to resumption of plant operation, and reporting as a Reportable Occurrence with prompt notification with written .

followup. The written followup of this report shall provide a description of investigations conducted to determine cause of the tube degradation and corrective measures taken to prevent recurrence.

~