Forwards Application for Amend to Licenses DPR-42 & DPR-60, Revising Tech Specs Re Steam Generator Tube Operability to Allow Continued Operation W/Three Defected Tubes Until Next Refueling Outage.Fee Encl
ML20090D406
Person / Time
Site: Prairie Island  Xcel Energy icon.png
Issue date: 07/09/1984
From: Musolf D
NORTHERN STATES POWER CO.
To:
Office of Nuclear Reactor Regulation
Shared Package
ML20090D408 List:
References
TAC-55237, NUDOCS 8407180230
Download: ML20090D406 (2)


Text

, , ..

_ n Northem States Power Company 414 Nicollet Mall Minneapolis. Minnesota 55401 Telephone (612) 330 5500 July 9, 1984 Director Office of Nuclear Reactor Regulation U S Nuclear Regulatory Commf.3sion Washington, DC 20555 PRAIRIE ISLAND NUCLEAR GENERATING PLANT Docket Nos. 50-282 License Nos. OPR-42 50-306 DPR-60 License Amendment Request dated July 9,~1934 Steam Generator Tube Operability Chance Reference (1): Letter dated June 18, 1994 from D M Musolf, NSP, to the Director of Nuclear Reactor Regulation, NRC, entitled,

" Supplemental Information Related to Prairie Island Unit No. 1 Steam Generator Tube Indications".

Attached are three originals and 37 conformed copies of a request for change to Technical Specifications, App <sudix A, of Operating License DPR-42 and DPR-60. In accordance with 10 CFR Part 170, a ,c. heck in the amount of $150.00 is enclosed.

Recently it was determined that three stea'a generator tubes in Unit l' exceedad the plugging criteria as a result of a post-outage third party review of eddy current data' . After reviewing the Technical Specifi-cations it was concluded that no Technical Specification violation occurred sineg Section 4.12, Steam Generator Tube 3urveillance, vc uld apply- during ' cold shutdown when the surveillanca is being conducted.

Technical Specification 3.1.C.6, limiting primary to secondary leakage to 1.0 gpm, applies duririg plan t' operation. This position was documented in Reference (1).

However, your Letter dated July 6, 1984 requested that NSP submit a one time amendme-t to Technical Specification 4.12.D.2' to allow continued operation with the three defected tubes. This license amendment is submitted in response to that request.

Exhibit A describes the proposed change, reason for chinge and significant hazards evaluation. Exhibit B contains the revised Technical Specification \

page.

1

\

0Y 0 at $f60'

e .

Dirsetor of NRR '

July 9, 1984 Page 2 Northem States Power Company Additional detailed background on this issue is provided in Reference (1) .

- Please contact us if you have any questions related to our request.

D;.9 w.

David Musolf Manager - Nuclear Support S ices i

DMM/EFE/bd c: Regional Administrator-III, NRC h NRR Project Ifanager, NRC  !

Resident Inspector, NRC [

G Charnoff ,

i Attachments t

i b l

i e

i P