PLANT SYSTEMS 3/4.7.9 HYDRAULIC SNUBBERS LIMITING CONDITION FOR OPERATION 3.7.9.1 All hydraulle snubbers listed in Table 3.7-3 shall be OPERABLE.

l APPLICABILITY:

MODES 1,2,3 and 4.

ACTION:

With one or more hydraulic snubbers inoperable, replace or restore the inoperable snubber (s) to OPERABLE status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

SURVEILLANCE REOUIREMENTS 4.7.9.1 Hydraulic snubbers will be demonstrated OPERABLE by performance of the following ajgmented inservice inspection program and the requirements of Specification 4.0.5.

l a.

Each hydraulle snubber with seal material fabricated from ethylene l

propylene or other materials demonstrated compatible with the operating environment and approved as such by the NRC, shall be determined l

OPERABLE at least once after not less than 4 months but within 6 months l

of initial criticality and in accordance with the inspection echedule of Table 4.7-4 thereafter, by a visual inspection of the snubber. Visual inspections of the snubber shall include, but are not necessarily limited to, inspection of the hydraulic fluid reservoirs, fluid connections, and linkage connections to the piping and anchors. Initiation of the Table 4.7-4 inspection schedule shall be made assuming the unit was previously at the 6 month inspection interval.

b.

Each hydraulle snubber with seat material not fabricated from ethylene propylene or other materials demonstrated compatible with the operating-environment shall be determined OPERABLE at least once per 31 days by a I

visual inspection of the snubber. Visual inspection of the snubbers shall l

include but are not necessarily limited to, inspection of the hydraulic fluid reservoirs, fluid connections, and linkage connections to the piping and anchors.

CRYSTAL RIVER - UNIT 3 3/4 7-25

~

8403200044 840312 PDR ADOCK 05000302 P.

PDR

Table 3.7-3 h

SAFETY RELATED HYDRAULIC SNUBBERS

  • M p:

SNUB 8ER SYSTEM SNUS8ER INSTALLED ON, ACCESSIBLE OR NIGH RADIATION ESPECIALLY DIFFICULT NO.

LOCATION ** AND ELEVATION _

INACCESSIBLE _

ZONE ****

TO REM)VE

,q

~

(A or I)

(Yes or Nol (Yes or No) h Decay Heat Removal System l

a:U DHH-17 R8

.110'-6" I

No No W

DHH-18 RB 110'-6" I

No No DHH-19 RB 109'-0" I

Na No DHH-20 RS2 115'-0" I

Yes No DHH-21 RS2 117'-0" I

Yes Yes DHH-22 RB2 117'-0" 1

Yes Yes l

DHH-23 RB 110'-6" I

No Y$s l

DHH-24 RB 109'-3" I

No A

l 1

DHH-25 RB 110'-6" I

No Yes l

w DHH-26H RB 110'-6" I

No No A,

DHH-26V RB 110'-6" I

No No y

DHH-27 R8 110'-6" I

= No yes DHH-35 R82 152'-5" I

Yes No DHH-36 R82 152'-5" I

Yes No DHH-37 RB2 159'-7" I

Yes Yes DHH '38 RS2 160'-1" I

Yes yes DHH-39 RB2 165'-9" I

Yes No DHH-661 A8 86'-6" A

Yes No DHR-18 A8 8A'-7" A

yes N,

DHR-21

. AB 103'-6" A

No No

~

DHR-24U A8 129'-6" A

No No DHR-24L AB 129'-6" A

No No DHR-28 AB 134'-4" A

No No DHR-31 A8 84'-9" A

Yes No DHR-37 A8 85'-6" A

Yes No l

DHR-49 A8 85'-6=

A Yes No

I Table 3.7-3 k

SAFETY RELATED HYDRAULIC SNU88ERS*

M M

SNUB 8ER SYSTEM SNU68ER INSTALLED ACCESSIBLE OR

-HIGH RADIATION ESPECIALLY DIFFICULT q

NO.

04, LOCATION ** AND ELEVATION INACCESSIBLE ZONE ****

TO REMVE (A or il (Yes or No)

(Yes or Nel g

Emergency Feedwater System U

EFN-14U R8 115'-0" I

No No W

EFH-14L R$

115'-0" 1

No No EFH-15U RB 115'-0*

I No No EFH-15L R8 115'-0" 1

No No EFH-27 RB2 145'-9" 1

Yes Yes EFH-28 RB2 145'-9" I

Yes Yes EFH-92 IB 140'-0" I

No No EFH-93 IB 131'-8" I

No No 2

.EFH-94 18 131'-8" A

No No w

EFH-95 IB 140'-0" A

"No No i

A, EFH-96 IB 141'-3" A

No No y

I No No EFH-106 IB 141'-3" I

EFH-107 ID 141'-3" A

No No EFH-108 IB 141'-3" A

No No EFH-109 18 133'-0" A

No No Ert!-110 18 133'-0" i

No No l

EFH-141 18 126'-6" A

No No EFH-143 IB 133'-6" A

No No EFH-144 IB 141'-3" I

No No i

a 4

4

}

i l

I

=

Table 3.7-3 k

SAFETY RELATED HYDRAULIC SNUB 8ERS*

M M

SNUBBER SYSTEM SNUB 8ER INSTALLED ACCESSIBLE OR HIGH RADIATION ESPECIALLY DIFFICULT NO.

04, LOCATION ** AND ELEVATION INACCESSIBLE ZONE ****

TO REM)VE 9

(A or il (Yes or No)

(Yes or No) h Feedwater System (Continued)

U FW -149 18 133'-0" I

No No

]

FWH-150 18 133'-0" A

No No FWH-151 IB 131'-0" A

No Ho FWH-152 IB 131'-0" A

No No FWH-153 18 131'-0" I

No No FWH-154 18 131'-0" l

No No FWH-155 IB 131'-D" I

No No l

FWH-156 18 131'-0" I

No "9

w i

i FWH-157 18 136'-0" I

No No FWH-158 IB 136'-0" I

~ No No 4,

FWH-159 IB 136'-0" I

No No l

y No No FWH-160 18 136'-0" A

FWH-161 18 136'-0" A

No No FWH-162 IB 142'-0" I

No No l

FWH-163 18 136'-U" A

No No FWH-164 18 136'-0" A

No No FWH-165 IB 134'-0" A

No No FWH-166 IB 134'-0" I

No No l

FWH-167 18 134'-0" I

No No I

FWH-168 18 134'-0" A

No No FWH-169 18 134'-0" I

No No l

FWH-170

-18 134'-0" A

No No FWH-171 IB 119'-0" A

No No l

f l-

i Table 3.7-3 k

SAFETY RELATED HYORAULIC SNUBBER $*

M

'M SNU88ER SYSTEM SNUB 8ER INSTALLED ACCESSIBLE OR HIGH RADIATION ESPECIALLY DIFFICIA.T

,q NO.

ON, LOCATION ** AND ELEVATION INACCESSIBLE ZONE ****

TO RE4 VE Q

(A or 1)

(Yes or No1 (Yes or No)

~

h Main Steam System U

MSH-117 18 122'-0" A

No No L

w MSH-118 18 122'-0" A

No No M5H-Il9 18 122'-0" A

No No i

M5H-120 18 122'-0" A

No No i

i M5H-121 18 122'-0" A

No No MSH-122 18 122'-0*

A No No MSH-123 18 122'-0" A

No No l

i MSH-124 18' 122'-0" A

No No 2

M5H-125 18 122'-0" I

No No w

4 MSH-126 18 122'-0" I

No No No No 4,

MSH-128 18

.122'-0" A

.* No No MSH-139 RB 133'-0" I

MSH-147 R8 139'-0*

I No Yes MSH-149 R8 at3'-0" I

No No i

MSH-150 RB 123'-0" I

No No MSH-156 RB 154'-0" I

No Yes

~

MSH-159 R8 148'-0" I

No Yes M5H-160 R8 112'-0" I

No No MSH-161

-R8 154'-0" I

No No MSH-162 RB 132'-0" 1

No Yes I

No Yes MSH-163 RB 138'-0" ~

I No No MSH-164 RB 123'-0" i

MSH-165 R8 123'-0" I

No No t

MSH-166 R8 148'-0" I

No Yes l

MSH-167 RB 148'-0" I

No Yes F

N U

"b 4

a Ow C

2 b

ppm

.4 w O

GGwOOOoOOOOoOOOOOOOOOOOOO 4 ac

>>>2222222222222222222222 om

, e UO G

U w

M em:

E.

=

O de 2

i 4

== e m

en e 6

ac alt e o

ooooeooOOooooeooooooOeoeo W

K aJ 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 *.c X 2 2 2 2 2 2 2 E

.-. $ (

E

.G N

>=

M 2

U M

8 e

aw N.

4 OJ et s

a M

O w.o.=

NN L e

  • .* w o

==e*..-.-

4aCaCaC e aC aC <aCaC CaC ( aC A

O Mv e

w Mu aC 5.'"

>==

W(

w 4

U2 J

U==

w 4

ac

'O

>=

2 G

W O

3 6

O ac 4

w v.-

M s*

a>

c (w

O

>- w U

en w w

2O g

e a s a e a e a e e a a e a a a s a e e a a a a :

2 w

3O00000000000000000000000 ac t W

.,e.e.e.a.e.e.e.e.e.e.e.e.e.e.e.e.o.e.e.e.e.e.e.e.a w

m m*

h N CD N N @ @ O O N CP W D m N O N N @ @== On @ w w m M

w W w M.e e.Me.Me.Me.N O M.e.Me m Ne is.Ne e.Me.M m o.M.O.O.O M

N w

2 wwe.

=

e.

E M.O e

G g aC w

wu M

>= 0 m an to.es. *en so. =e e.e.n.a =e.a.e m e.e. ac se.e. m.s.e e.an =a en se as ac sg

=

===== -

- en M.J C

a=

e M +

e*

E L

e ac e os O e @ N e os O e Ne e e N M w W W W W m m oft m m M w f% N O M GD Ch O.e N M w m

@ e ee N N N N N N N N N N N N N N N N N N N N N N w

OOOOO.

e.

e *

== -

O e e e e e o e e e e e e e e a e e e e e e o e e e 2

EEEEEEEEEEEEEEEEEEEEEEEE mmAAAmAmAAAmmmmAAAAAAAAm M

EEEEEEEEEEEEEEEEEEEEEE.TE CRYSTAL RIVER - UNIT 3 3/4 7-33 l

.,, ~.., -..,,.

4..

.,,,,<e

.,g,e,

,,s..

,-n.,

7_

9ay TABLE 4.7-4 t.

iS H.YDRAULIC SriUBBER INSPECTION SCHEDULE N

o 8

NUMBER OF SNUBBERS FOUND INOPERABLE NEXT REQUIRED

. E DURING INSPECTION OR DURING INSPECTION INTERVAL (*)

INSPECTION INTERVAL (* *, +)

U w

0 18 months + 25%

1 12 months 7 25%

~

2 6 months 25 %

l' 3 or 4 124 days 1-25 %

- 5, 6, or 7 62 days 1 25 %

Greater than or equal to 8 31 days 1 25 %

w1

?

.M 1

I I

l I-Snubbers may be categorized into two groups, " accessible" and " inaccessible". This categorization shall be based upon the snubber's accessibility for inspection during reactor operation. These two groups may be inspected independently according to the above schedule f

The required inspection interval shall not be lengthened more than one step at a time. Following the 1983 refuelin.- 7tage, the first I

inservice visual inspection of accessible snubbers shall be performed after 4 months but within 10 months of co.- ~aencing POWER f

l OPERATION. Subsequent intervals shall be determined by the above Table.

I For the duration of Cycle Five, as many inaccessible snubbers as possible shall be visually inspected during any mid-cycle outage (s).

+

These inspections should not increase the duration of the outage (s).

L l

f