ML20083P968

From kanterella
Jump to navigation Jump to search

Revised Application for Amend to Licenses DPR-57 & NPF-5, Changing Tech Specs Re Transversing in-core Probe Sys, Hydrogen & Oxygen post-accident Monitoring & HPCI & RCIC
ML20083P968
Person / Time
Site: Hatch  
Issue date: 04/16/1984
From: Gucwa L
GEORGIA POWER CO.
To: Stolz J
Office of Nuclear Reactor Regulation
Shared Package
ML20083P972 List:
References
TASK-2.F.1, TASK-2.F.2, TASK-2.F.3, TASK-TM NED-84-203, TAC-48294, TAC-53454, TAC-53455, TAC-54461, TAC-54462, TAC-54495, TAC-98294, NUDOCS 8404200284
Download: ML20083P968 (2)


Text

.

.. =.

ic Georgia Power Cornpany 333 Piedmont Avenuts Atlanta. Georgia 30308 Telephono 404 5266526 MaAng Ad1ress:

Post Oftce Box 4545 Atlanta Georgia 30302 Georgia Power i

L T.Gucwa the southern etwtnc system Manager Nuciear Engineenng and chief Nuclear Engineer NED-84-203 April 16,1984 i

Director of Nuclear Reactor Regulation Attention: Mr. John F. Stolz, Chief Operating Reactors Branch No. 4 Division of Licensing U. S. Nuclear Regulatory Commission Washington, D. C.

20555 L

NRC DOCKETS 50-321, 50-366 OPFRATING LICENSES DPR-57, NPF EIMIN I. HATCH NUCLEAR -PLA!C UNITS 1, 2 REVISION OF PREVIOUS REQUESTS FOR ItilflICAL drt:CIFICATION AMENINENTS Gentlemen:

On December 21, 1983, Georgia Power Company (GPC) submitted two separate requests for changes to the Plant Hatch Technical Specifications.- One of these letters proposed changes to the Unit 2 requirements for usage of the -

i Traversing Incore Probe (TIP) system;. the other letter proposed changes to the restrictions. for operation of the Hydrogen (H ) and Oxygen. (0 )

2 2

Analyzers in both Hatch units.

On February 6,

1984, GPC. submitted a proposal to change the Unit 1 Technical Specification operability limit for the High Pressure Coolant Injection '(HPCI) system and the Reactor Core Isolation Cooling -(RCIC) system.

Each ~ of. these submittals contained a i

significant hazards evaluation as required by 10 CFR 50.92 (Attachment 3 to the. HPCI/RCIC and TIP submittals; Attachments 4 and. 5 to the H2 and 02 analyzer submittal).

l-Recently,- GPC revised its methodology for conducting significant hazards l

reviews for-Technical Specification change proposals.

As a result of this, l

GPC has rewritten the wording. submitted to~ the NRC by - the above three letters. None of the revised reviews results in a change to the conclusionsi drawn in the original submittals.

The four attachments enclosed with this letter should be used to replace the. appropriate attachments to-these l

- previous submittals.- Note that the attachment mmbers and titles at.the: top l'

of ' the. erclosures to -this letter coincide with the headings used in the' previous subaittals.

9404200284 840416 PDR ADOCK 05000321 h

P.,

PDR 5

-e-yav r

p,y f

  • -9 1

V W"-

-9&

f-T

Georgia Power 1 Director of Nuclear Reactor Regulation Attention: Mr. John F. Stolz, Chief Operating Reactors Branch No. 4 April 16,1984 Page Two Pursuant to the requirements of 10 CFR 50.91, Mr. J. L. Ledbetter of the Environmental Protection Division of the Georgia Department of Natural Resources will be sent a

copy of this letter and all applicable attachments.

/ f Q-m+

L. T. Gucwa CBS Enclosure xc:

H. C. Nix, Jr.

Senior Resident Inspector J. P. O'Reilly, (NRC-Region II)

J. L. Ledbetter P

700775

.,