MONTHYEARML20009E8641981-05-31031 May 1981 Revised Main Control Room Habitability Study Project stage: Other ML20009E8541981-07-20020 July 1981 Forwards Revised Main Control Room Habitability Study, Per NUREG-0737,Item III.D.3.4.Revision Corrects Errors in Radiological Analysis Assumptions.Mods Recommended in Toxic Chemical Study Will Be Scheduled for Completion by 830101 Project stage: Other ML20024B0851983-07-0101 July 1983 Application to Amend Licenses DPR-42 & DPR-60,revising Tech Specs Re Containment Sys Recombiners,Control Room Air Treatment Sys & Ref to FSAR Table 7.7-2 Project stage: Request ML20024B0831983-07-0101 July 1983 Forwards Application to Amend Licenses DPR-42 & DPR-60, Revising Tech Specs Re Containment Sys Recombiners,Control Room Air Treatment Sys & Ref to FSAR Table 7.7-2.Changes Do Not Constitute Significant Hazards Consideration Project stage: Request ML20024B0871983-07-0101 July 1983 Proposed Tech Specs Re Containment Sys Recombiners,Control Room Air Treatment Sys & Ref to FSAR Table 7.7-2 Project stage: Other ML20077N9441983-08-26026 August 1983 Application for Amend to Licenses DPR-42 & DPR-60, Changing Tech Specs Re Addition of Instruments to Event Monitoring Instrumentation & Chlorine Detection Sys Project stage: Request ML20077N9221983-08-26026 August 1983 Forwards Application for Amend to Licenses DPR-42 & DPR-60, Changing Tech Specs Re Addition of Instruments to Event Monitoring Instrumentation & Chlorine Detection Sys Project stage: Request ML20077N9561983-08-26026 August 1983 Proposed Tech Specs Re Event Monitoring Instrumentation & Chlorine Detection Sys Project stage: Other ML20079G0381984-01-13013 January 1984 Forwards Application for Amend to Licenses DPR-42 & DPR-60, to Provide Assurance of Reactor Coolant Vent Sys Operability & Reliability,Implementing Requirements of NUREG-0737,Item II.B.1 Project stage: Request ML20079G0461984-01-13013 January 1984 Application for Amend to License DPR-42 & DPR-60,providing Assurance of Reactor Coolant Vent Sys Operability & Reliability,Implementing Requirements of NUREG-0737,Item II.B.1 Project stage: Request ML20079G0541984-01-13013 January 1984 Proposed Tech Spec Changes Providing Assurance of Reactor Coolant Vent Sys Operability & Reliability Project stage: Other ML20088A2551984-03-27027 March 1984 Safety Evaluation Supporting Amends 69 & 63 to Licenses DPR-42 & DPR-60,respectively Project stage: Approval ML20088A8861984-04-10010 April 1984 Forwards Application to Amend Licenses DPR-42 & DPR-60, Revising Tech Specs in Response to Generic Ltr 83-37,to Implement Requirements of NUREG-0737,Items II.B.3,II.F.1.2 & III.D.3.4 Project stage: Request ML20088A8931984-04-10010 April 1984 Application to Amend Licenses DPR-42 & DPR-60,revising Tech Specs in Response to Generic Ltr 83-37 to Implement Requirements of NUREG-0737,Items II.B.3,II.F.1.2 & III.D.3.4 Project stage: Request ML20088A8961984-04-10010 April 1984 Proposed Tech Specs in Response to Generic Ltr 83-37, Implementing Requirements of NUREG-0737,Items II.B.3, II.F.1.2 & III.D.3.4 Project stage: Other ML20090D3981984-06-20020 June 1984 Toxic Chemical Study Project stage: Other ML20090D3761984-07-0909 July 1984 Suppl 1 to 840410 Application for Amend to Licenses DPR-42 & DPR-60,changing Tech Specs to Delete Requirement for Ammonia,Hydrocloric Acid & Formaldehyde Gas Detection Sys in Main Control Room,Per NUREG-0737,Item III.D.3.4 Project stage: Request ML20090D3651984-07-0909 July 1984 Forwards Suppl 1 to 840410 Application for Amend to Licenses DPR-42 & DPR-60,changing Tech Specs to Delete Requirement for Ammonia,Hydrocloric Acid & Formaldehyde Gas Detection Sys in Main Control Room,Per NUREG-0737,Item III.D.3.4 Project stage: Request ML20108B1621984-10-25025 October 1984 Corrected Amends 70 & 64 to Licenses DPR-42 & DPR-60, Respectively,Adding Tech Spec 3.14-4 Re Operator Action for Inoperable Containment Ventilation Isolation Sys, Inadvertently Omitted from 840912 Amends Project stage: Other ML20106J8841984-10-26026 October 1984 Advises That Manual Isolation Valves in Unit 1 Vent Line Blocked & Tagged in Accordance W/Requirements of Tech Spec 4.18.Tech Spec for Reactor Coolant Vent Sys Implemented Project stage: Other 1984-10-25
[Table View] |
Text
,
Northem States Power Company 414 Nicollet Malt Minneapoks. Minnesota 55401 Telephone (612) 330-5500 August 26, 1983 Director Office of Nuclear Reactor Regulation U S Nuclear Regulatory Commission Washington, DC 20555 PRAIRIE ISLAND PUCLEAR GENERATING PLAITT Docket Nos. 50-282 License Nos. DPR-42 50-306 DPR-60 License Amendment Request dated July 1, 1983, Revision 1 Chlorine Detection and Recombiner Systems Technical Specification Changes Attached are three originals and 37 conformed copies of a revision to our License Amendment Request dated July 1, 1983. A license amendment fee for this revision was determined to be unnecessary because it is within the scope of the License Amendment class determination and fee that was included with the original submittal.
This submittal proposes changes to the Event Monitoring Instrumentation Table by addition of three instruments.
In addition, a new page TS.3.13-1A is submitted to supercede the page which was submitted on July 1,1983.
Exhibit A contains the proposed changes, reasons for the change, and Signif-icant Hazards Evaluations. Exhibit B contains the revised Technical Specifi-cation pages.
D h._ s David Musolf Manager - Nuclear Support Se ices DMM/SAF/bd cc: Regional Administrator-III, !RC NRR Project Manager, IRC Resident Inspector, ITRC G Charnoff MPCA Attn; J W Ferman Attachments