CONTAINMENT = SYSTEMS 3/4,6.3 CONTAINMENT ISOLATION VALVES LIMITING CONDITION FOR OPERAT]ON 3.6.3 The containment isolation valves shall be OPERABLE.*

l

'APPLICABillTY:' MODES 1, 2, 3, and 4.

ACTION:

With one or more _of the containment isolation valve (s) inoperable, maintain at least one isolation valve OPERABLE in each affected penetration that is open and:

Restore the inoperable valve (s) to OPERABLE status within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />, a.

or Isolate each affected penetration within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> by use of at least b.

one-deactivated automatic valve secured in the isolation position, or Isolate'ench affected penetration within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> by use of at least c..

one closed manual valve or blind flange, or d.

Be in at least HOT-STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

The provisions of Specification-3,0.4 are not applicable provided e.

that the affected penetration is isolated in accordance with ACTION L

b or e above, and provided that the associated system, if applicable, is declared inoperable and the appropriate ACTION statements for that system are performed.

SVRVElltANCE RE001REMENTS 4.6.3.l' The containment isolation valves shall be demonstrated OPERABLE prior to returning the valve to service after maintenance, repair or replacement work is performed on the valve or its associated actuator.. control or power circuit -

by performance of a cycling test, and verification of_ isolation time.

l L

l'

- *lsolation valves associated with the containment hydrogen monitors may be opened on an intermittent basis under administrative control.

j.

lV0GTLE. UNITS--1&2 3/4 6-16

-9105080092 910503 L

PDR ADOCK 05000424 P-PDR g.

. _ _. _.. _. _ _.. _.,. _..,. _ _ _.. _.. _ -_.2,_._

CONTAINMENT SYSTEMS O / 5 9 T~

3/4.6.3 CONTAINMENT ISOLATION VALVES

)

LIMITING CONDITION FOR OPERATION 3.6r3 The'contairnent isolation valves shall be OPERABLE.

~)

E APPLICABILITY: MODES 1, 2. 3, and 4.

ACTION:

Witn one or more of the containment isolation valve (s) inoperable, maintain at least one isolation valve OPERABLE in each affected penetration that is cpen and:

Restore the inoperable valve (s) to OPERABLE status within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />, a.

or Isolate each affected penetration within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> by use of at least b.

one deactivated automatic valve secured in the isolation position, or Isolate each affected penetration within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> by use of at least c.

one closed manual valve or blind flange, or Be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD d.

SHUT,DOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />, The provisions of Specification 3.0.4 are not applicable provided e.

that the af fetted penetration is isolated in accordance with ACTION b or e above, and provided that the associated system, if applicable, is declared inoperable and the appropriate AC110N statements for that system are performed.

SURVElLtANCE REQUIREMENTS The containment isolation valves shall be demonstrated OPERABLE prior 4.6.3.3 to returning the valve to service af ter maintenance, repair or replacement work is performed on the valve or its associated actuator, control or power circuit by performance of a cycling test, and verification of isolation time.

45306/472-b WITH TM-C&fl2lAJMer/T MA/hulli7b6

  • bOL4DOJVdlV&S Ms} Bs-cPar/ED &J AU / YTe2M/YTes.fr BMt3 u2?&2 RMidiST2snV6-OQLIT5DL n

... ~

- - - - - - - - ~ _ - _ _ _ _ _ _ _ _

9 4

4 ENCLOSURE 4 VOLTLE ELECTRIC GENERATING PLANT TECHNICAL SPECiflCATION CHANGE OPENING Of CONTAINMENT ISOLATION VALVES TO FACILITATE CALIBRATION Of THE CONTAINMENT HYDROGEN MONITORS MARK-VP Of AffECTED FSAjLPJ1(S l

~

O

  • 6 VEGP-TEAR-16 t

TABLE 16.3-4 (SHEET 8 0F 15)

Valve Closure

~~

' valve Time (s)

Num.ber Function Remote Manual (continued)

N/A HV-1978 ACCW Supply N/A HV-1979 ACCW Supply N/A HV-1974 ACCW Return N/A HV-1975 ACCW Return N/A HV-8835 Safety injection to cold leg HV-8802B Safety injection to hot leg N/A HV-8802A Safety injection to hot leg N/A Containment spray emergency sump suction N/A HV-9002D HV-9002A Containment spray emergency sump suction N/A Reactor coolant pump seal water supply N/A HV-8103D Reactor coolant pump seal water supply N/A HV-8103B Reactor coolant pump seal water sup;ty N/A HV-8103C Reactor coolant pump seal water supply N/A HV-8103A N/A HV-8840 RHR pump discharge to hot leg N/A HV-8809A RHR loop into cold leg N/A HV-8809B RER loop into cold leg HV-8701A RHR suction from hot leg N/A

[

HV-8702A RHR suction from hot leg N/A N/A HV-5278'b' Chemical addition N/A HV-5279'b' Chemical addition HV-2791A )

Containment H monitor suction N/A U

y Ed2

e..

VEGP-FSAR-16 TABLE 16.3-4 (SHEET 9 or 15)

~

Valve Closure

  • Valve Number Function Time (s)

Remote Manual (continued)

HV-2790A containment H m nitor suction N/A 2

HV-2790B Containment H2 "'"It'# ""'ti""

N/A HV-2793A Containment H monitor discharge N/A f

N 2

HV-2192B "

Containment H2 **"it I

""'*A*"

N/A HV-2791B Containment H monitor suction N/A 2

N HV-2792A Containment H m nitor suction N/A 2

b HV-2793B Containment H monitor discharge N/A 2

HV-5194 Auxiliary feedwater N/A

.HV-5197 Auxiliary feedwater N/A HV-5195 Auxiliary feedwater N/A HV-5196 Auxiliary feedwater N/A HV-9556A Steam generator secondary side sample N/A HV-9556B' Steam generator secondary side sample N/A HV-9555A Steam generator secondary side sample N/A HV-9555B Steam 9enerator secondary side sample N/A-HV-9554A Steam generator secondary side sample N/A HV-9554R Steam generator secondary side sample N/A 4 -

HV-9553A Steam 9enerator secondary side sample N/A HV-9553B Steam genefator secondary side sample

'N/A HV-3009 Main steam to auxiliary feedwater pump N/A driver 6*W 3

I ew.

VEGP-FSAR-16

(

TABLE 16.3-4 (SHEET 15 or 15)

P

~

See FSAR Section 6.2.4 for discussion of the c66teinment

(

a.

isolation system.

b.

Air supply valves closed and enclosed in lockable boxes to provide sealed, closed barrier, i

c.

Locked closed.

The These valves are included for table completeness.

d.requirements of Technical Specification 3/4.6.3 do not apply; instead 'he requirements of Technical Specification 4.5.2.e.1 apply.

Valve stroke times where specified will be tested pursusat to specification 4.0.5.

These-valvea are included for table completeness.

The requirements of Technical Specification 3/4.6.3 do not apply; e.

instead the requirements of Technical Specification 4.7.4 apply.

Valve stroke times where specified will be tested l

s pursuant to specification 4.0.5.

These valves are included for table completeness.

The f.requirements of Technical specification 3/4.6.3 do not apply; instead the requirements of Technical Specification 4.6.2.1 apply.

Valve -terme times where specified will be tested pursuant to s[ STROKE cification 4.0.5.

These valves are included for table completeness.

The g.requirements of Technical Specification 3/4.6.3 do not apply; instead the requirements of Technical Specil'4 cation 3/4.7.1.5 and 3/4.3.2 apply to the main steam isolation and bypass valves and main feedwater isolation valves, respectively.

These valves are included for table completeness.

The h.requirements of Technical Specification 3/4.6.3 do not apply; instead the requirements of Technical Specification 3/4.7.1,2 apply.

Valve stroke times where specified will be tested pursuant to specification 4.0.5.

i. Th Vkves Md Se OPeJeo od m nJreeMITudT 86 sis I

udihR somir/t,5resrtVE &>UTeot..

(

.