Text
,
l..
m-DMI IIILEi ES-1.3 TRANSFER TO COLD LEG RECIRCULATION PAGE 1 of 19 7'N, o
ROCHESTER GAS AND ELECTRIC CORPORATION GINNA STATION CONTROLLED COPY NUMBER TECHNICAL REVIEW
~~
PORC REVIEW DATE (l
-v
. E //bd PLAN'i' SUPERINTENDENT N~ ') ~ I Y EFFECTIVE DATE 1
CATEGORY l.O REVIEWED BY:
Ch
-V A
9404190138 940414 PDR ' ADOCK 05000244 P
r 4..
EOP:
TITLE:
ES-1,3 TRANSFER TO COLD LEG RECIRCULATION PAGE 2 of 19.
-Q/
A.
PURPOSE - This procedure provides the necessary instructions for transferring the Safety Injection system and Containment spray system to recirculation modes of operation.
B.
ENTRY CONDITIONS / SYMPTOMS 1.
ENTRY CONDITIONS - This procedure may be entered from:
a.
E-1, LOSS OF REACTOR OR SECONDARY COOLANT, or, b.
ECA-0.2, LOSS OF ALL AC POWER WITH SI REQUIRED, or, c.
ECA-2.1, UNCONTROLLED DEPRESSURIZATION OF ALL STEAM GENERATORS, or, d.
FR-C.1, RESPONSE TO INADEQUATE CORE COOLING, or, e.
FR-C.2, RESPONSE TO DEGRADED CORE COOLING, or, f.
FR-C.3, RESPONSE TO SATURATED CORE COOLING, or, g.
FR-H.1, RESPONSE TO LOSS OF SECONDARY HEAT SINK, or, pg h.
FR-Z.1, RESPONSE TO HIGH CONTAINMENT PRESSURE, on low (j
RWST level.
i.
Other procedures whenever RWST level reaches the i
switchover setpoint (28%).
O
1._- -.- --
_ s" EOP:
I!TLE:
REV: 16 ES-1,3 TRANSFER TO COLD LEG RECIRCULATION PAGE 3 of 19 i
O
~~
STEP ACTION / EXPECTED RESPONSE RESPONSE NOT OBTAINED CAUTION' INJECTION FLOW TO THE RCS SHALL BE MAINTAINED AT ALL TIMES.
o IF OFFSITE POWER IS LOST AFTER SI-RESET, THEN SELECTED SW PUMPS AND ONE o
CCW PUMP WILL AUTO START ON EMERGENCY D/C. MANUAL ACTION WILL BE REQUIRED TO RESTART SAFEGUARDS EQUIPMENT.
CONSULT WITH RADIATION PROTECTION BEFORE DISPATCHING PERSONNEL TO o
AUXILIARY BUILDING.
NOTE:
o FOLDOUT page should be open and monitored periodically.
Adverse CNMT values should be used whenever CNMT pressure is-o greater than 4 psig or CNMT radiation is greater than 10+05.R/hr.
IF RWST level is less than 28% 6JN nO GREATER THAN 113 INCHES CNMT. sump B level is less than 113 inches, THEN go to ECA-1.2,-
LOCA OUTSIDE CONTAINMENT, Step 1.
NOTE:
Steps 2 through 11 should be performed without delay.
FR procedures should not be implemented prior to completion of these steps.
2 Reset SI
-. i 9
i 1
u l
EOP:
T11LE:
REV: 16
-ES-1.3' TRANSFER TO COLD LEG RECIRCULATION PAGE 4 of 19
- \\,
STEP ACTION / EXPECTED RESPONSE RESPONSE NOT OBTAINED NOTE:
IF D/Gs supplying emergency AC busses, THEN non-essential loads may be shed as necessary to allow start of additional SW pumps.
3 Establish Adequate SW Flow:
a._ Verify at least two SW pumps -
- a. Start additional SW pumps as RUNNING power supply permits (258 kw each).
IF only 1 SW pump operable, THEN perform the following:
- 1) Ensure Attachment MIN SW is complete.
- 2) Go to Step 4.
- b. Verify AUX BLDG SW isolation
- MOV-4615 and MOV-4734
()
- c. Perform the following:
flow to CCW Hxs - GREATER THAN 5000 GPM
- 1) Isolate SW!to screenhouse and i
air conditioning headers.
/i MOV-4609 and MOV-4780
{
- MOV-4663 and MOV-4733
- 2) Direct Ao to locally adjust total SW flow to the CCW Hxs to between 5000~gpm and 6000 gym (V-4619 and V-4620).
- SFP Hx B (V 8689)
- 4) Verify SW portions of Attachment SD-1 arel complete.
O 1
'I n
- e.,
l, REV: 16 ES-1,3 TRANSFER TO COLD LEG RECIRCULATION PAGE 5 of 19 ACTION / EXPECTED RESPONSE RESPONSE NOT OBTAINED STEP 4 Establish CCW flow to RHR Hxs:
- a. Check both CCW pumps - RUNNING
- a. Start CCW pumps as power supply 1
permits (124 kw each).
- b. Dispatch A0 to locally open Hxs valves.
- MOV-738A
- MOV-738B CAUTION o CONSULT WITH RADIATION PROTECTION BEFORE DISPATCHING PERSONNEL TO AUXILIARY BUILDING.
THE RHR HX OUTLET VALVES (HCV-624 AND HCV-625) WILL FAIL OPEN ON LOSS OF o
INSTRUMENT AIR PRESSURE.
5 Check RHR Flow:
Manually adjust RHR Hx outlet valves equally to reduce flow to Both RHR pumps - RUNNING less than 1500 gpm per operating 1
o pump.
o RHR flow (FI-626) - LESS THAN 1500 GPM PER OPERATING PUMP
- RHR Hx B, HCV-624-
- RHR Hx A, HCV-625 J.F flow can NOT be reduced manually,-THEN dispatch an A0 to locally adjust RHR Hx outlet manual-valves equally to reduce flow.-
- RHR Hx B', V-715-
- RHR Hx A, V-717 O
=_
EOP2 IlfLE:
REV: 16 ES-1 3 TRANSFER TO COLD LEG RECIRCULATION PAGE 6 of 19 N, /
STEP ACTION / EXPECTED RESPONSE RESPONSE NOT OBTAINED CAUTION ANY PUMPS TAKING SUCTION FROM RWST SHOULD BE STOPPED UPON REACHING RWST LO-LO LEVEL ALARM.
6 Check IF Unnecessary Pumps Can Be Stopped:
a.
Three SI pumps - RUNNING
- a. Go to Step 6c,
- b. Stop SI pump C and place both switches in PULL STOP
- c. Both CNMT spray pumps - RUNNING
- c. Pull stop any idle CNMT spray pump and go to Step 6e.
- d. Pull stop one CNMT spray pump Stop both RilR pumps and place in c.
PULL STOP l
i l
i i
u
)
j
4 F.09 :
IITLE:
REV: 16 ES-1.3 TRANSFER TO COLD LEG RECIRCULATION 1
PAGE 7 of 19 0
)
i STEP ACTION / EXPECTED RESPONSE RESPONSE NOT OBTAINED 7 Verify Ri!R System Alignment:
- a. Verify the following valves -
- a. Ensure at least one suction CLOSED valve and one discharge valve
- closed, o RiiR suction valves from loop A hot leg
- MOV-700
= MOV-701 RllR discharge valves to loop o
B cold leg
- MOV-720
- MOV-721
- b. Verify RHR pump suction crosstic
- b. Manually open valves.
If valves valves - OPEN can NOT be opened, THEN dispatch p
A0 to locally open valves.
- MOV-704A
- MOV-704B c.
Verify the following valves -
- c. Ensure at least one valve in OPEN each set open, o RilR pump discharge to Rx vessel deluge valves
- MOV-852A
- MOV-852B RHR suction f rom swrp B o
(inside CNMT)
- MOV-851A
- MOV-851B
- d. Verify RCDT pump suction valves
- d. Manually close valves.
f rom sump B - CLOSED
- MOV 1813A
- MOV 1813B i(
6.
EOP:
iliLE:
REV: 16 ES-1.3-TRANSFER TO COLD LEG RECIRCULATION PAGE 8 of 19 1% '
ACTION / EXPECTED-RESPONSE RESPONSE NOT OBTAINED STEP CAUTION RHR FLOW INDICATED ON FI-626 SIIOULD BE LIMITED TO 1500 GPM PER OPERATING PUMP TO ENSURE OPTIMUM PUMP PERFORMANCE.
8 Initiate RHR Sump Recirculation:
- a. Dispatch A0 to locally close pump suction, MOV-856 (turn on valve and continue with Step 8b.
DC power key switch)
- b. Open both RHR suction valves
THEN perform the following:
o MOV-850A - OPEN
- 1) Initiate only one train of RHR recirculation (Refer to O'
o MOV-850B - OPEN Attachment RHR NPSH for-further guidance).
- 2) Go to 8d.
E neither valve will open, THEN refer to Attachment RHR PRESS REDUCTION for further guidance.
- c. Start both RilR pumps
- d. Verify at least one RHR pump -
- d. E no RER pump can be started, RUNNING THEN go to ECA-1.1, LOSS OF EMERGENCY COOLANT RECIRCULATION,..
Step 1.
'?
l 5
i{
O
-~
. ~.. - -
LOP:
title:
REV: 16 ES-1.3-TRANSFER TO COLD LEG RECIRCULATION PAGE 9 of 19
'Q ACTION /EXPECTEDRESPONbCl
' RESPONSE NOT OBTAINED STEP NOTE: The TSC should be requested to establish periodic monitoring of the AUX BLDG sub-basement, as radiological conditions permit, to monitor RHR pump operation.
m 9 Check RWST Level - LESS THAN DO NOT continue with this procedure 15%
until RWST level is less'than 15%.
10 Stop All Pumps Supplied From RWST:
Stop all SI pumps and place in a.
PULL STOP
- b. Stop all charging pumps
- c. Stop operating CNMT spray pump and place in PULL STOP
- d. Check CNMT pressure - LESS THAN
- d. Go to Step 11.
28 PSIC Reset CNMT spray if necessary e.
- f. Close CNMT spray pump discharge valves 1
c
- MOV-860A
- MOV-860B
- MOV-860C
- MOV-860D
-l
.i 3
I k.
LO l.
j s
e r-w n
- e..e v,
y
~
e
",a,-
~
e
,e w,--,
-... -.. -... ~
~
1 f.
~
EOP:
IITLE:
REV: 16 ES-1.3.
TRANSFER TO COLD LEG RECIRCULATION PAGE 10 of 19 STEP ACTION / EXPECTED RESPONSE RESPONSE NOT OBTAINED CAUTION RHR FLOW MUST BE MAINTAINED LESS THAN 1500 GPM PER OPERATING RHR PUMP AS DETERMINED BY THE TOTAL OF FI-931A, F1-931B AND FI-626 INDICATIONS.
11 Align SI And CNMT Spray For Sump Recirculation:
- a. Verify SI pump suction valves
- a. Ensure at least one valve in from BASTS - CLOSED each flowpath closed.
- MOV-826A and MOV 826B
= MOV-826C and MOV-826D
- b. Close and verify closed RWST
- b. Ensure at least one valve closed, outlet valves to SI and CNMT spray pumps (turn on DC power key switches)
- MOV 896A
- MOV-8968 Close and verify closed SI pump
- c. Ensure at least one valvo closed.
c.
RECIRC valves
- MOV-898
- MOV-897
- d. Verify SI pump suction valves
- d. Ensure at least one valve open.
from RWST - OPEN l
- MOV-825A
- MOV 825B
- e. Align RHR Hx outlet flow paths
- c. Ensure at least one flowpath to SI and CNMT spray pump suction aligned from RHR pump (s) to SI and CS pump suction header.
o MOV-857A and MOV-857C - OPEN
.(Refer to Attachment.RER SYSTEM).
o MOV-857B OPEN JF neither flow path,can be aligned, THEN refer to Attachment RHR PRESS REDUCTION O
for~further guidance.
4 E@s iliLE:
REV: 16 ES-1.3 TRANSFER TO COLD LEG RECIRCULATION PAGE 11 of 19
(N s_ /
STEP ACTION / EXPECTED RESPONSE RESPONSE NOT OBTAINED CAUTION S1 PUMPS SHOULD BE STOPPED IF RCS PRESSURE IS CREATER THAN TilEIR S!!UTOFF HEAD
12 Verify Adequate RCS Makeup Flow:
a, RCS pressure - LESS THAN
- a. Perform the following:
225 psig {425 psig adverse CNMT}
- 1) Check RCS conditions:
o RCS subcooling based on core exit T/Cs greater
,j than Figure MIN SUBC00 LING.
PRZR level greater than 5%
o
[30% adverse CNMT}.
IP either condition NOT met, TilEN start one SI pump.
- 2) Co to Step 13.
- b. RHR injection flow adequate:
b Start one SI pump, o Core exit T/Cs - LESS TRAN REQUIREMENTS OF FIGURE RHR INJECTION Check RVLIS level (no RCPS) -
o GREATER THAN 43% [46% adverse CNMT)
O
I (OP:
lilLE:
REV: 16 ES-1.3 TRANSFER TO COLD LEG RECIRCULATION PAGE 12 of 19 O
~
- V ACTION / EXPECTED RESPONSE RESPONSE NOT OBTAINED STEP CAUTION IF A CNMT SPRAY PUMP IS STARTED, TilEN CNMT PRESSURE Sil0ULD BE CLOSELY MONITORED.
CNMT PRESSURE S1100LD NOT BE REDUCED TO LESS TilAN 32 PSIC.
13 Check If CNMT Spray Is Required:
a.
CNMT pressure - CREATER TilAN
- a. Perform the following:
37 PSIG
- 1) If CNMT spray previously actuated and NaCll tank level greater than 55%, TilEN consult TSC to determine if CNMT spray should be restarted.
g
- 2) Go to Step 14.
- b. Verify CNMT spray pump discharge
- b. Manually open valve (s) for valves OPEN selected pump.
- MOV-860A
- MOV-860B
- CS pump B, MOV-860C or MOV-860D
- MOV-860C
- MOV 860D
- c. Start selected CNMT spray pump
- d. Open Na0ll tank outlet valves for running pump
.e.
(OP:
TITLE:
REV:'16 ES-1,3 TRANSFER TO COLD LEG RECIRCULATION PAGE 13 of 19
\\
ACTION / EXPECTED RESPONSE UdSPONSE NOT OBTAINED STEP 14 Verify Adequate Core Cooling:
lE both RHR pumps running, TilEN ensure two SI pumps running, o Core exit T/Cs - STABLE OR DECREASING
-lE only one RilR-pump running, THEN perform the following:
o RVLIS level (no RCPs) - STABLE OR INCREASING
THEN start one additional SI" Pump.
CAUTTON IF CST LEVEL DECREASES TO LESS THAN 5 FEET, THEN ALTERNATE WATER SOURCES FOR AFW PUMPS WILL BE NECESSARY (REFER TO ER-AW.1, ALTERNATE _ WATER' SUPPLY TO AFW PUMPS).
j NOTE:
TDAFW pump flow control valves fail open on loss of IA.
i
- 15 Monitor Intact S/G Levels:
- a. Narrow range level - GREATER
- a. Maintain total feed flow greater-THAN 5% [25% adverse CNMT}
than.200 gpm until narrow. range-
-l level greater than 5%.[25%
adverse-CNMT] in at least one S/G.
'l b, Control feed flow to maintain
~
narrow range level between 17%
(25% adverse CNMT) and 50%
O
'l
_E,-
.1 f@t fliLE:
REV: 16
~'
ES-1.3 TRANSFER TO COLD LEG RECIRCULATION PAGE 14 of 19 0
U STEP ACTION / EXPECTED RESPONSE RESPONSE NOT OBTAINED i
-16 Establish-Normal Shutdown Alignment:
- a. Check condenser - AVAILABLE
- a. Dispatch A0 to perform Attachment SD 2.
- b. Perform the following:
o Open generator disconnects
- 1G13A71 9X13A73 a
Place voltage regulator to 0FF o
o Open turbine drain valves Rotate reheater steam supply o
controller cam to closo valves
()
Place reheater dump valve o
switches to HAND o Stop all but one condensate Pump Verify adequate Rx head cooling:
c.
- 1) Go to Step 16d.
- 2) Verify at 1 cast one control
- 2) Manually start one fan as rod shroud fan - RUNNING power supply permits (45 kw)
- 3) Verify one Rx compartment
- 3) Perform the following:
cooling fan - RUNNING o Dispatch ~AO'to reset UV
t Manually start one fan'as~
o power supply permits (23 kw) 1
- d. Verify Attachment SD 1 - COMPLETE O
u
. _..~.
EOP:
fliLE : -
REV: '16 ES-1.3 TRANSFER TO. COLD LEG RECIRCULATION PAGE 15 of 19 1.
.m STEP ACTION / EXPECTED RESPONSE RESPONSE NOT OBTAINED 17 Check'If Emergency D/Gs Should Be Stopped:
- a. Verify AC emergency busses
- a. Try to restore offsite power energized by offsite power:
(Refer to ER-ELEC.1, RESTORATION OF OFFSITE POWER).
Emergency D/G output breakers o
- OPEN AC emergency bus voltage o
GREATER THAN 420 VOLTS o AC emergency bus normal feed breakers - CLOSED
- b. Stop any unloaded emergency D/G and place in standby (Refer to Attachment D/G STOP)
Y s
E 4
.w, yv.,
j ibP' TITLE:
REV: 16 ES-1.3 TRANSFER TO COLD LEG RECIRCULATION PAGE 16 of 19
/'s V
STEP ACTION / EXPECTED RESPONSE RESPONSE NOT OBTAINED 18 Check If SI ACCUMs should Be Isolated:
- a. Both RCS hot leg temperatures -
- a. Continue with Step 19.
WilEN LESS TilAN 400*F both RCS hot leg temperatures less than 400*F, THEN do Steps 18b through d.
- b. Dispatch A0 with locked valve key to locally close breakers for SI ACCUM discharge valves
- c. Close SI ACCUM discharge valves
- c. Vent any unisolated ACCUMs:
- ACCUM A, MOV-841
- 1) Open vent valves for
- ACCUM B, MOV-865 unisolated SI ACCUMs.
((
- ACCUM A, A0V-834A
- ACCUM B, A0V-834B
- 2) Open HCV-945,
- d. Locally reopen breakers for MOV-841 and MOV-865 O
_^
riEF:
iiiLEs REV: 16 ES-1.3 TRANSFER TO COLD LEG RECIRCULATION PAGE 17 of 19 r~
v ACTION / EXPECTED RESPONSE RESPONSE NOT OBTAINED STEP CAUTION IF FUEL DAMAGE IS SUSPECTED, MAINTAIN S/G PRESSURE SLIGHTLY GREATER THAN RCS PRESSURE.
19 Check If Intact S/Gs Should Be Depressurized To RCS Pressure:
- a. RCS pressure - LESS THAN INTACT a.
Go to Step 20.
S/G PRESSURES
- b. Check S/G radiation - NORMAL
- b. Do NOT dump steam from a S/G with high radiation.
Isolate o Steamline Monitors (R-31, feed flow to a S/G with high R-32) radiation.
O o Direct HP to sample S/Gs for activity c.
Dump steam to condenser from
- c. JJF steam dump to condenser NOT intact S/G(s) until S/G pressure available, THEN dump steam using less than RC3 pressure intact S/G ARVs until S/G pressure less than RCS pressure.
20 Consult TSC to Determine If RX Vessel Head Should Be
)
Vented i
m
.y_._
m.
._._a.
. e s
EOP:
iliLE:
REV: 16 ES-1.3-TRANSFER TO COLD LEG RECIRCULATION PAGE'18-of 19
-'r STEP ACTION / EXPECTED RESPONSE RESPONSE NOT OBTAINED NOTE:
This procedure should be continued while obtaining CNMT hydrogen sample in Step 21.
21 Check CNMT Hydrogen Concentration:
- b. Hydrogen concentration - LESS
- b. Consult TSC to de.termine if THAN 0.5%
hydrogen recombiners should be placed in service-.
NOTE:
The TSC should be consulted before changing recirculation lineups.
22 Check Event Durat. ion -
Consult TSC to evaluate long term GREATER THAN 19 HOURS AFTER plant status.
EVENT INITIATION O
23 Place CNMT Spray Pumps In PULL STOP 24 Verify Two SI Pumps - RUNNING Manually start pumps.
25 Check Core Exit T/Cs - LESS Perform the following:
THAN REQUIREMENTS OF FIGURE 1
RHR INJECTION
- a. Manually open both PRZR PORVs and block valves, i
- b. Verify core exit T/Cs decreasing.
to less than requirements of Figure RHR INJECTION, IF NOT, THEN dump steam'from intact S/Gs until core exit T/Cs less than-.
required.
O
.. -.. a..
. o- - -
e Y
[ '
iliLE:
~
g REV: 16 ES-1,3 TRANSFER To COLD LEG RECIRCULATION PAGE 19 of 19
.(~)
'q,/
STEP ACTION / EXPECTED RESPONSE RESPONSE NOT OBTAINED 26 Consult TSC To Evaluato Long Term Plant Status
-END-O l
l m)
~
e
'EOP:
fliLE:
-ES-1.3 TRANSFER TO COLD LEG RECIRCULATION PAGE 1 of 1 ES-1,3 APPENDIX LIST TITLE PAGES 1)
RED' PATH
SUMMARY
1 2)
FIGURE RHR INJECTION 1
3)
FIGURE MIN SUBCOOLING 1
4)
ATTACHMENT D/G STOP 1
5)
ATTACHMENT SD-1 1
6)
ATTACHMENT SD-2 1
7)
8)
ATTACHMENT RHR SYSTEM 1
9)
ATTACHMENT AUX BLDG SW 1
-(
10)
\\
11)
ATTACHMENT MIN SW 1
12)
ATTACHMENT RHR PRESS REDUCTION 1
13)
FOLDOUT 1
l O
i tw:
rint REV: 16 ES-1.3 TRANSFER TO COLD LEG RECIRCULATION PAGE 1 of 1 f'~))
\\_
BED PATH
SUMMARY
a.
SUBCRITICALITY - Nuclear power greater than 5%
b.
CORE COOLING - Core exit T/Cs greater than 1200*F
-OR-Core exit T/Cs greater than 700*F AND RVLIS level (no RCPs) less than 43% [46%
adverse CNMT) c.
HEAT SINK - Narrow range level in all S/Gs less than 5%
(25% adverse CNMT] AND total feedwater flow less than 200 gpm d.
INTEGRITY - Cold leg temperatures decrease greater than 100*F in last 60 minutes AND RCS cold leg temperature 1
- than 285'F e.
CONTAINMENT - CNMT pressure greater than 60 psig V)
(
O
E04 ilTLE:
REV: 16 ES-1,3 TRANSFER TO COLD LEG RECIRCULATION PAGE 1 of 1 g
U FIGURE RI.N SUBCOOLING NOTE:
Subcooling Margin = Saturation Temperature From Figure Below (-] Core Exit T/C Indication RCS PRESSURE (PSIG) 2500
- txt c _;g,_gn _; r. _4~EEf_ - __r_ ~-,_yiM..._
="-ty+._ _,_;d_. /
i
=
+- 2
~ " " * - " -
~~
' ~3mt"-r 2400
~ - ~ ~=
~~~~~ ' ~ -
~~
~
=
-==:=c;-:::22 :-
+
~ rI:
=t==t =~-Et - 1 =m -t a i-+ +, tds/+F
=p;;
2300 - -.1 RCS PRESSURE t
= __ -
___r._;
-_#__,_g
-+~
t INCREMENTS 20 PSIG 4_p, _ r__.L.24_+t._-d__ M _t-.
r-
+
=t=,
._t t
2_._-
2200
_4-_
+
.. 4.
r.
, ~._b_,p...pt_.c g~trelk-
-pj=~Eb_~
... W p.
...+..e_.-+.
_r n-.e-_--4.
cg
~~~. :pgg -.,_m.~4_Lgp~q~_._7~
.-4
^7_. ' '. -~" _1 t:
a:; p
--+
1 2100
~"
- --*- ~-
- -~
~
~~
~
g'** =~b'tq"=*:t.
tric a g##
m t:
=rct
=
t-
~"p*"~gp*-"t r._
a-
~
~ - " " " ~'
2000
:sg=t ct - p~i-:=t= c u rrct td
rtrggy-It+r ^
=t_.w w.t_
c :n;=t e e
r;~t-
/".I.p/.7%.rt:--t ::
21:1_. !:
._.-.~__.,_t n=4.~.. c 1900 -
~__.__._1_
=1_ g..,=_
_ _. _g
_EE"+i E#-~I~
+_,~ td-- **-~ 9 It=c -=t*_E~tr,t --w- 'E=t,-:
i;
+'F~
_t_.__-
r--
+
1800 m:
7~~~
~**
^'
c
=
r}:n_~tt ;rH-=pyEe: =ctgn== ppt =p g=g;;- - p.1 _r-t-
r g: q-m=gE/ei.= f -+ < s,_
,- =t= =._t-
._._w
._ts 1700
=_p.-
-c._
- 1
.tt _
~*n_p_ gg4_
_- _v m - g, --. - - _ w
_-+
-+-
-r
= 4g_g. r~~3_4_trp =;g-y_t- *&__ _;-d;
- - = d4 ~
"i-
.+
~
r-
=
1600
=
~
-*- ~ - ' - "
'~' -
~~"
=
- 1dy=
1500 ** :
"cp=*=FW "p*q==w= pp qq=t
- =:
=r g *q=p=t ;q r p~7p-g~**~ -t=r: ;
- * ~ ~ " ' "
- " " " - " "#=
~"
n=p~*__ +:t r-m cpt gg:d1=~=t=t=t * " ~ F* r ~r"-
~M~~ = E PC 1~~m s
- =
==
4#
~
"##~=t 1400
~-"""
%n"S._c=
==t._=sSUBC00 LED
=a l=2:1- *a-tu- =r i
" -+"
= - t
q=5._i=-t-
2*
REGION
= m =t=2m>(_
_.5. 5_=1_-a_u.
2==="=
-+ :
=
c 1300--
~-
t-e o
3::tzt_r n7r=;m
- rpp
_f_uatzg.
mrpp:
et_t: =wgi.a-:=t,__
__ r._.r?:r 4 t-gi-
=c
- y. _
7 -f;_ rfat.. ;, = _t-,_p=_
1200 x
~
_, _..a y_-_"r% st r,ge+g=._=g[_4u_7:_ +__=%_tch. Er_7- _.
~
j e
.. 9...
~" ~
2=
_, < _- g g4,_ _._._g_; #
cg:-
1.
- * *
- t: ;?d7#-
_74
~
1 r
E b,_ c-t
1100
- "r :txt-
' - -~
c I
-.5' O-~
~ ~*9_ f.=_-F._ff =-
"4.4== "~ 4~=6 4
t tr. t-crt-T.1.-
t 1000 m s zt ;r
_J_ __-t-ta..-
4- _._
_g q_.j_.
_.r.p..g
- T L.+
i -t :.
a._.__-.
,p
_s
_, +
_,_+m
, _g=a_
_r_
rt tu e g g ;,___i_g up-3_g,_,_
900, _, __ w.p~. __
.w_,,__ a_ p.-~ + J_a _
~t: _3 r= 3..+___ c g
._ _r
! i 1 ~g_g
-+ 1=t_,-
t__
a
_.r.-
t j w
~~-g
_; _g._ _
a
_+_y_._ 7,_ ;
_.e.c j_ _
__ _tr
~ ~ "r e{-= p-" +
. gp-
- 5. _
~
~~~+"-
~
a 800 7
T~"'p~~"I_
~c
-~
- ~ F t:
tt ~
- ~" t t
~M g==F** =p#* "g===g.g:p= g" E=EF"==F=*C
j
r#
bwa+r INADEQUATE
_E.-J 700-c"t,-
p~ iEEEE
=U.g!
=i=' u= =rt*-" r
~
c is 5 m -t-t~-
SUBC00 LING
- C-
" ct:
=*
- d *'~
^ ~~
- ~
600 ~
=
2~
+~=
'"~
~~~
REGION ADVERSE CNMT
~~gger 43_ 45g g4
+- pg
_tg~ "q='-
500-gfj-
_+
p+ " O tm
-+
2 b"g"=~ ":rr
=r7*_
"gg#
=p m_ry*.= 23"-~"-"per-t 2,'-,-
"*=
b
="
- ~
400
=tgrpr.p=*= U "m t- +rts: g=b*Ur a' m "t+-_ n-4 p*t-
~~~
4-5
- (_t n~ -+, ",1
- 3*
~2"
~ ~ ~-4 300-I *~
- =
t:
t S:."_ct t m E3~=t e'~d=3= :Ct=Ei-
= "!- m ~ ' t= m = a"b*a_ _ 'ar.- :t Tt -~
~ ^ ~ ~
~-~
tm m g
200-
,_gt=
- rrjit-NORMAL CNMT g TEMPERATURE
=c+.tr m +%7-
+-
+
m p:..a-_r. -
i
" "+
INCREMENTS 10*F 100
~m
~~~
~ *-
- -~
~~
=t c c ret;g= ncrp t -Mp12
- nrt=Ctrmt.F.=t=5EF.r
=-t-txtur
- t3~44- '+t
+tH <
r &
=tt_i _.E
~
rt-i. "=1-
- t=ur 0j
=ht m
-tirt:C -la_ ta:
t:ts 200 250 300 350 400 450 500 550 600 650 700 CORE EXIT SATURATION TEMPERATURE (*F)
O
I l
EQP;
_ _..illLE8 ES-1.3 TRANSFER TO COLD LEG RECIRCULATION i
PAGE 1 of 1 p
O FIGURE RHR INJECTION
-l CORE EXIT TEMPERATURE (
- f) 600
..{. 4L-Ti t i-T t-
.L Lg.pp g_h tA_. _
i
_{
j 1EMPERATURE 7r
'tr-J i
T---
INCREMENTS 10*F pg ifTt-1 T
ftri-Ti TU TTTi~f JT TTITT~~T ~ tit
~ ~f~ ---T-i i1 t-~
550 1
J1L._ L 1 ill i.L;._J.LLL I
._i_
1 i
_h_{
.q _.j
._._d.L__da[._
d.2_L_
_. _.._d I._
i.
_._d_ I t..Ji._1L 4.._
- _Jl_Lh4 I
LL d_4_J4
..._L
_._LL L._
.1 j
.._-_p_ p._
___p.
l _qpk____
_ _t i j4LL
. _4 4
.__._p.
1 _L.
l 1
~
}
. q.--
q
_L
~
450
[
_. 4 7.y
_+
_. q_
_LL.
. J... L.q_p p {i __lq_4._ _} __{g_p.
___[L_
_J__._
..y 7.
_rq._
_7..g.. __..p.p.
q_b_
q_. 4n.p _p _[q_
.7 7 p.
[. _..t r INITIATE HIGH fi fI iiIT 7i
.A
.7
....q__
_g.[...i.__.__ld 4L_L g_HEADINJECTION ijja.
_. q _...4 p_,_.q.
T 1.ll'l
. 4_
ZZ _T_Il~}
]..
y._..y 1
L i_Lt.
i L_L_
L_.
i S1 I!
.J.._L 4 -t-h_E ~11 b
- I~!
l-
._g -~g jll r [ +!
o i ilt+
- 1 rm
,ir g.4 Jy4 i..{...jdL
{_
.l. I
_f__.
_ J1
- _Q.L._
i L_
L
_41 4.
i 4._
. y.ii.
L+
r-w L.
_p
_L_
{.i 4__....._L_.p.___ l..... t-' _.1
--~m t(_
k L
H-7' i!
RHR INJECTION I
250
- .4LL JJ i
_.41 ~l I ADEQUATE I
I I
q13'.4LJ.
L_L.
I-CNMT PRESSVRE
_ L _.
_ _L
_..__!_J
_LJd__L L
' INCREMENTS 1 PSIG 7.h_
l p.
77 l';
._._f.._7 0
10 20 30 40 50 60 CONTAINMENT PRESSURE (PSIG)
O
F g 1 09:
ti rII:
REV: 16 ES-1.3 TRANSFER TO COLD LEG RECIRCULATION PAGE 1 of 1
( m.
- d._
FOLDOUT PAGE 1.
SI REINITIATION CRITERIA IF EITHER condition listed below occurs, THEN operate SI pumps manually as necessary:
o Core exit TCs - GREATER THAN REQUIREMENTS OF FIGURE RHR INJECTION 2B o
RVLIS level - LESS THAN 43% [46% adverse CNMT) 2.
AFW SUPPLY SWITCHOVER CRITERION IF CST level decreases to less than 5 feet, THFN switch to.
alternate AFW water supply (Refer to ER-AFW.1, ALTERNATE WATER SUPPLY TO AFW PUMPS).
o V