EOP:
FR-C.2 TITLE:
RESPONSE
TO DEGRADED CORE COOLING REV:
9 PAGE 1 of 14 ROCHESTER GAS AND ELECTRIC CORPORATION GINNA STATION CONTROLLED COPY NUMBER TECHNICAL REVIEW PORC REVIEW DATE 3
PLANT SUPERINTENDENT EFFECTIVE DATE CATEGORY 1.0 REVIEWED BY:
4.00ip b8
~+o+00+244 PDR A
1
'I
~
I l
K
EOP:
FR-C.2
RESPONSE
TO DEGRADED CORE COOLING REV 9
PAGE 2 of 14 A.
PURPOSE This procedure provides actions to restore adequate core cooling.
B.
ENTRY CONDITIONS/SYMPTOMS l.
ENTRY CONDITIONS This procedure is entered from:
a.
F-0.2, CORE COOLING Critical Safety Function Status
- Tree, on any ORANGE condition.
EOP:
FR-C.2
RESPONSE
TO DEGRADED CORE COOLING REV:
9 PAGE 3 of 14 STEP ACTION/EXPECTED RESPONSE
RESPONSE
NOT OBTAINED NOTE:
Adverse CNMT values should, be used whenever CNMT ~ressure is greater than 4 psig or CNMT radiation is greater than 10+
R/hr.
1 Check RWST Level GREATER THAN 284 Perform the following:
a.
Ensure SI system aligned for cold leg recirculation using Steps 1 through 11 of ES-1.3, TRANSFER TO COLD LEG RECIRCULATION.
b.
Go to Step 3.
EOP:
FR-C.2 TITLE:
RESPONSE
TO DEGRADED CORE COOLING REV:
9 PAGE 4 of 14 STEP
,ACTION/EXPECTED RESPONSE
RESPONSE
NOT OBTAINED 2 Verify SI Pump And RHR Pump Emergency Alignment:
a.
RHR pump discharge to Rx vessel deluge OPEN
~ MOV-852A
~ MOV-852B a.
Ensure at least one valve open.
- b. Verify SI pump C
RUNNING
- b. Manually start pump on available bus.
- c. Verify SI pump A -
RUNNING
- d. Verify SI pump B -
RUNNING
- c. Perform the following:
- 1) Ensure SI pumps B and C
running.
- 2) Ensure SI pump C aligned to discharge line A:
o MOV-871B closed o
MOV-871A open 3)
Go to Step 3.
- d. Perform the following:
- 1) Ensure SI pumps A and C
running.
- 2) Ensure SI pump C aligned to discharge line B:
o MOV-871B open o
MOV-871A closed
- e. Verify both SI pump C discharge valves OPEN
~ MOV-871A
~ MOV-871B 3)
Go to Step 3.
- e. Manually open valves as necessary.
EOP:
FR-C.2 TITLE:
RESPONSE
TO DEGRADED CORE COOLING REV 9
PAGE 5 of 14 STEP ACTION/EXPECTED RESPONSE
RESPONSE
NOT OBTAINED 3 Verify SI Pump Suction aligned to RWST:
a.
SI pump suction valves from RWST OPEN
~ MOV-825A
~ MOV-825B a.
Ensure at least one SI pump suction valve from RWST open
~ MOV-825A
~ MOV-825B
- b. SI pump suction valve from BASTs CLOSED
~ MOV-826A
~ MOV-826B
~ MOV-836C
~ MOV-826D b.
Ensure at least one valve in each SI pump suction line from BAST closed.
~ MOV-826A or MOV-826B
~ MOV-826C or MOV-826D 4 Verify SI Flow In Both Trains:
a.
SI line'oop A and B flow indicators CHECK FOR FLOW a.
Perform the following:
l) Manually start SI pumps and align valves as necessary.
- 2) Establish maximum charging flow.
b.
RCS pressure LESS THAN 250 psig
[465 psig adverse CNMT]
c.
RHR loop flow indicator CHECK FOR FLOW b.
Go to Step 5.
- c. Manual'ly start RHR pumps and align valves.
EOP:
FR-C.2 TITLE:
RESPONSE
TO DEGRADED CORE COOLING REV' PAGE 6 of 14 STEP ACTION/EXPECTED RESPONSE
RESPONSE
NOT OBTAINED x **************
x***
CAUTION IF ANY PRZR PORV OPENS BECAUSE OF HIGH PRZR
- * * * * * * * * * * * * * * * * * * * * * * * * * * *
- 4 * * * * * * * * *:**
5 Check RCS Vent Path@:
a.
Power to PRZR PORV block valves AVAILABLE
- a. Restore power to block valves unless block valve was closed to isolate an open PORV:
b.
PORVs CLOSED
~ MOV-515, MCC C position 6C' MOV-516, MCC D position 6C
- b. IF PRZR pressure less than 2335 psig, THEN manually close PORVs.
IF any PORV can NOT be closed, THEN manually close its block valve.
- c. Block valves
- AT LEAST ONE OPEN c.
Open one block valve unless it was closed to isolate an open PORV.
d.
Rx vessel head vent valves CLOSED
- d. Manually close valves.
~ SOV-590
~ SOV-591
~ SOV-592
~ SOV-593
4
- t. '.
~
EOP:
FR-C.2
RESPONSE
TO DEGRADED CORE COOLING REV' PAGE 7 of 14 STEP ACTION/EXPECTED RESPONSE
RESPONSE
NOT OBTAINED NOTE:
Normal conditions for running RCPs are desired, but RCPs should not be tripped if normal conditions cannot be established "or maintained.
6 Check RCP Status:
- a. At least one RCP RUNNING a.
Go to Step 9.
- b. Try to establish support conditions for the operating RCP.
7 Check RVLIS Fluid Fraction
- a. Fluid fraction (any RCP on)
GREATER THAN 60%
- a. IF increasing, THEN return to Step 1.
IF NOT, then go to Step 8.
- b. Return to procedure and step in effect.
8 Check If One RCP Should Be Stopped:
a.
Both RCPs RUNNING
- b. Stop one RCP c.
Go to Step 10 a.
Go to Step 10.
EOP:
FR-C.2
RESPONSE
TO DEGRADED CORE COOLING REV' PAGE 8 of 14 STEP ACTION/EXPECTED RESPONSE
RESPONSE
NOT OBTAINED 9
Check Core Cooling:
a.
GREATER THAN 43%
[46% adverse CNMT]
- a. IF increasing, THEN return to Step 1.
IF NOT, THEN go to Step 10.
b.
Core exit T/Cs LESS THAN 700'F
- b. IF decreasing, THEN return to Step 1.
IF NOT, THEN go to Step 10.
- c. Return to procedure and step in
.effect 10 Check SI ACCUM Discharge Valves OPEN
~ MOV-841
~ MOV-865 IF SI ACCUM discharge valves closed after ACCUM discharge, THEN go to Step ll.
IF NOT, THEN perform the following:
~ MOV-841, MCC C position 12F
~ MOV-865, MCC D position 12C b.
Open SI ACCUM discharge valves.
~ ACCUM A, MOV-841
~ ACCUM B, MOV-865
EOP:
FR-C.2 TITLE:
RESPONSE
TO DEGRADED CORE COOLING REV:
9 PAGE 9 of 14 STEP ACTION/EXPECTED RESPONSE
RESPONSE
NOT OBTAINED
- * * * * * * * * * *
- x * *
- x * * * * * *
- x x
- x
- x
- x
- x * * * * * *
- CAUTION o
IF CST LEVEL DECREASES TO LESS THAN 5 FEET, THEN ALTERNATE WATER SOURCES FOR AFW PUMPS WILL BE NECESSARY (REFER TO ER-AFW.1, ALTERNATE WATER SUPPLY TO AFW PUMPS).
o A FAULTED OR RUPTURED S/G SHOULD NOT BE USED IN SUBSEQUENT STEPS UNLESS NO INTACT S/G IS AVAILABLE.
x x **x x ******************
NOTE:
TDAFW pump flow control valves fail open on loss of IA.
- ll Monitor Intact S/G Levels:
a.
Narrow range level GREATER THAN 5%
[25% adverse CNMT]
- b. Control feed flow to maintain narrow range level between 17%
[25% adverse CNMT] and 50%
- a. Increase total feed flow to restore narrow range level greater than 5%
[25% adverse CNMT] in at least one S/G.
12 Verify Condenser Steam Dump In Manual:
- a. Verify condenser available:
o Intact S/G MSIV -
OPEN a.
Place intact S/G ARV controller in MANUAL and go to Step 13.
o Annunciator G-15, STEAM DUMP ARMED - LIT
- b. Place steam dump mode selector switch in MANUAL
- c. Place steam dump controller in MANUAL
I 1
EOP:
FR-C.2 TITLE:
RESPONSE
TO DEGRADED CORE COOLING REV:
9 PAGE 10 of 14 STEP ACTION/EXPECTED RESPONSE
RESPONSE
NOT OBTAINED
- x**x*x************%
CAUTION THE FOLLOWING STEP WILL CAUSE SI ACCUMULATOR INJECTION WHICH MAY RESULT IN A RED PATH CONDITION IN F-0.4, INTEGRITY STATUS TREE.
THIS PROCEDURE SHOULD BE COMPLETED BEFORE TRANSITION TO FR-P.1,
RESPONSE
TO IMMINENT PRESSURIZED THERMAL SHOCK.
13 Depressurize All Intact S/Gs To 200 PSIG:
- a. Maintain cooldown rate in RCS cold legs LESS THAN 100'F/HR b.
Dump steam to condenser
- b. Manually or locally dump steam from intact S/Gs:
o Use S/G ARVs.
-OR-o Open TDAFW pump steam supply valve(s) for affected S/G(s):
~ S/G A, MOV-3505A
~ S/G B, MOV-3504A
-OR-o Locally perform the following:
o Open intact S/G MSIV bypass valve.
o Open priming air ejector steam isolation valves.
~ V-3580
~ V-3581 c.
Check S/G pressures LESS THAN 200 PSIG
- c. Return to Step 11.
d.
Stop S/G depressurization
.I l
EOP:
FR-C.2 TITLE:
RESPONSE
TO DEGRADED CORE COOLING REV' PAGE 11 of 14 STEP ACTION/EXPECTED RESPONSE
RESPONSE
NOT OBTAINED
~ *4 *********************
CAUTION RHR PUMPS SHOULD NOT BE RUN LONGER THAN 1 HOUR WITHOUT CCW TO THE RHR HEAT EXCHANGERS.
x ****x
- x x x *******************
14 Check RHR Pumps RUNNING Manually start pumps as necessary.
15 Check If SI ACCUMs Should Be Isolated:
a.
RCS hot leg temperatures BOTH LESS THAN 400'F a.
Go to Step 17.
- b. Dispatch AO with locked valve key to locally close breakers for SI ACCUM discharge valves if necessary
~ MOV-841, MCC C position 12F
~ MOV-865, MCC D position 12C
- c. Close SI ACCUM discharge valves
~ MOV-841
~ MOV-865
- c. Vent any unisolated ACCUMs:
- 1) Open vent valves for unisolated SI ACCUMs.
~ ACCUM A, AOV-834A
~ ACCUM B, AOV-834B
- d. Locally reopen breakers for MOV-841 and MOV-865
- 2) Open HCV-945.
EOP:
FR-C.2 TITLE:
RESPONSE
TO DEGRADED CORE COOLING REV 9
PAGE 12 of 14 STEP ACTION/EXPECTED RESPONSE
RESPONSE
NOT OBTAINED
- x ****x **% x *************************
CAUTION SYMPTOMS FOR FR-C.1,
RESPONSE
TO INADEQUATE CORE COOLING, SHOULD BE CLOSELY MONITORED DURING SUBSEQUENT STEPS.
16 Stop All RCPs 17 Depressurize All Intact S/Gs To Atmospheric Pressure:
- a. Maintain cooldown rate in RCS cold legs LESS THAN 100'F/HR b.
Dump steam to condenser
- b. Manually or locally dump steam from intact S/Gs:
- 1) Use S/G ARVs.
1
- 2) Open TDAFW pump steam supply valve(s) for affected S/G(s):
~ S/G A, MOV-3505A
~ S/G B, MOV-3504A
- 3) Locally perform the following:
o Open intact S/G MSIV bypass valve.
o Open priming air ejector steam isolation valves.
~ V-3580
~ V-3581
EOP:
FR-C.2 jITLE:
RESPONSE
TO DEGRADED CORE COOLING REV' PAGE 13 of 14 STEP ACTION/EXPECTED RESPONSE
RESPONSE
NOT OBTAINED 18 Verify SI Flow:
o SI line loop A and B flow indicators CHECK FOR FLOW Perform the following:
a.
Continue efforts to establish SI flow.
-OR-o RHR loop flow indi.cator CHECK FOR FLOW
- b. Try to establish maximum charging flow.
- c. Return to Step 17.
19 Isolate Both SI ACCUMs:
a.
Close SI ACCUM discharge valves
~ MOV-'841
~ MOV-865
- a. Vent any unisolated ACCUMs:
- 1) Open vent valves for unisolated SI ACCUMs
- b. Locally reopen breakers for MOV-841 and MOV-865
~ ACCUM A, AOV-834A
~ ACCUM B, AOV-834B
- 2) Open HCV-945.
20 Stop All RCPs 21 Check Core Cooling:
GREATER THAN 68%
[73% adverse CNMTj o
Both RCS hot leg temperatures LESS THAN 320'F Return to Step 17.
EOP:
FR-C.2
RESPONSE
TO DEGRADED CORE COOLING REV:
9 PAGE 14 of 14 STEP ACTION/EXPECTED RESPONSE
RESPONSE
NOT OBTAINED 22 Go to Appropriate Plant Procedure a.
Check RWST level GREATER THAN 28' b.
Go to E-l, LOSS OF REACTOR OR SECONDARY COOLANT, Step 17
-END-a.
Go to ES-1.3, TRANSFER TO COLD LEG RECIRCULATION, Step 1.
I II
EOP:
FR-C.2
RESPONSE
TO DEGRADED CORE COOLING REV:
9 PAGE 1 of 1 FR-C.2 APPENDIX LIST TITLE 1)
ATTACHMENT RCP START PAGES
ECP:
FR-C.3
RESPONSE
TO SATURATED CORE COOLING REV 5
PAGE 1 of 5 ROCHESTER GAS AND ELECTRIC CORPORATION GINNA STATION CONTROLLED COPY NUMBER TECHNICAL REVIEW PORC REVIEW DATE PLANT SUPERINTENDENT EFFECTIVE DATE CATEGORY 1.0 REVIEWED BY:
(fm I
EOF.
FR-C.3
RESPONSE
TO SATURATED CORE COOLING REV:
5 PAGE 2 of 5 A.
PURPOSE - This procedure provides actions to restore core cooling.
B.
ENTRY CONDITIONS/SYMPTOMS 1.
ENTRY CONDITIONS This procedure is entered from:
a.
F-0.2, CORE COOLING Critical Safety Function Status
- Tree, on a YELLOW condition.
I
EOP:
FR-C.3
RESPONSE
TO SATURATED CORE COOLING REV:
5 PAGE 3 of 5 STEP ACTION/EXPECTED RESPONSE
RESPONSE
NOT OBTAINED NOTE:
o If either ECA-3.2, SGTR WITH LOSS OF REACTOR COOLANT -
SATURATED RECOVERY DESIRED or ES-1.3, TRANSFER TO COLD LEG RECIRCULATION is i'n effect, this procedure should not be performed.
o Adverse CNMT values should be used whenever CNMT pressure is greater than 4 psig or CNMT radiation is greater than 10+
R/hr.
1 Check RHR Normal Cooling-NOT IN SERVICE Refer to AP-RHR.1, LOSS OF RHR.
2 Check RWST Level GREATER THAN 284 Ensure SI system aligned for cold leg recirculation using Steps 1
through 11 of ES-1.3, TRANSFER TO COLD LEG RECIRCULATION.
3 Verify SI Flow:
a.
SI line loop A and B flow indicators CHECK FOR FLOW b.
RCS pressure
- LESS THAN 250 psig (465 psig, adverse CNMTj c.
RHR loop flow indicator CHECK FOR FLOW
- a. Manually start SI pumps and align valves.
b.
Go to Step 4.
- c. Manually start RHR pumps and align valves.
c h
EOP:
FR-C.3 tlTLE:
RESPONSE
TO SATURATED CORE COOLING REV' PAGE 4 of 5 STEP ACTION/EXPECTED RESPONSE
RESPONSE
NOT OBTAINED x ~ *******************
CAUTION IF ANY PRZR PORV OPENS BECAUSE OF HIGH PRZR
4 Check PRZR PORVs And Block Valves:
a.
Power to PORV block valves AVAILABLE
- a. Restore power to block valves unless block valve was closed to isolate an open PORV:
b.
~ MOV-515, MCC C position 6C
~ MOV-516, MCC D position 6C
- b. IF PRZR pressure less than 2335 psig, THEN manually close PORVs.
IF any PORV can NOT be closed, THEN manually close its block valve.
- c. Block valves
- AT LEAST ONE OPEN c.
Open one block valve unless it was closed to isolate an open PORV.
d.
Rx vessel head vent valves CLOSED
- d. Manually close valves.
~ SOV-590
~ SOV-591
~ SOV-592
~ SOV-593
v g1
FR-C.3
RESPONSE
TO SATURATED CORE COOLING REV:
5 PAGE 5 of 5 STEP ACTION/EXPECTED RESPONSE
RESPONSE
NOT OBTAINED 5 Return To Procedure And Step In Effect
-END-