4 P-26 Page 1 Of 6

sie leeue$

ENective Date

(

Jersey Central 2/24/81 (01/70/83) 01/30/g3 Power & L. ht Company Revision No.

Date ig Subject ACTIVATION OF THE TECHNICAL 1

11/2/82 SUPPORI CENTER Authonzed By a

Director-Station Operations Approval / Concurrence y

Project Oyster Creek Nuclear Generating Station LIST OF EFFECTIVE PAGES DATE REVISION NUMBER 1

11/2/82 1

2 11/2/82 1

3 11/2/82 1

4 11/2/82 1

5 11/2/82 1

6 11/2/82 1

ATTACHMENTS EPIP 26-1 (1 page) 11/2/82 1

EPIP-26, Figure 1 (1 page) 11/2/82 1

EPIP-26, Figure 2 (1 page) 11/2/82 1

NON-CONTROLLED This Document Will NOt Be Kept Up To Date (s.

DCC Oyste Creek 0302100087 830214 PDR ADOCK 05000219 F

PDR

l Seastesc Pressenare Ne, ACTIVATION OF THE TECHNICAL EPIP-26 2

6 g

g SUPPORT CENTER Monson No.

1 Cete 11/2/82 1.0 PURPOSE This procedura describes the activation, initial operation, and recovery of the Technical Support Center.

2.0 REFERENCES

2.1 EPIP-2 Unusuel Event 2.2 EPIP-3 Alert 2.3 EPIP-4 Site Emergency 2.4 EPIP-5 Geniral Emergency 2.5 EPIP-25 Nearsite Emergency Operations Facility 3.0 RESPONSIBILITIES 3.1 The Eme,rgency Director is responsible to evaluate conditions and direct the activa

3.2 The Technical Support Center Coordinator is responsible for the efficient activation of the TSC and to. carry out the requirements of this procedure.

4.0 P_REREQUISITES 4.1 The TSC may be activated upon any of the following:

4.1.1 Unusual Event 4.1.2 Alert 4.1.3 Site Emergency 4.1.4 General Emergency 4.1.5 By direction of the Emergency Director 5.0 PRECAUTIONS 5.1 The following precautions will be observed:

e

-r

e Susper:

l Proceeure N&

, ACTIVATION OF THE TECHNICAL' EPIP-26 Pege 3 of 6 8egee SUPPORT CENTER Renmon as 1

can' ll/2/82

[

5.1.1 Use proper respiratory protective devices as directed by Radiological Controls 5.1.2 Use proper dosimetry as directed by i

Radiological Controls.

5.1.3 Maintain radiation / airborne radioactivity level surveillance during emergency operations.

5.1.4 Proper frisking techniques will be followed by all personnel prior to entering the TSC.

6.0 REQUIREMENTS NUTE:

l Tha Technical Support Center is located adjacent to the the Turbine Building in the vicinity of the Core

\\

Engineering Office.

6.1 Upon notification that the Technical Support Center is

)

being activated, the Oyster Creek Nuclear Generating Station Security Department will ensure its accessibility and security.

6.2 The TSC Coordinator, using fonn EPIP 26-1, will ensure i

completion of the following:

6.2.1 Establish a single entry point with frisking i

l station.

f

\\

6.2.2 Continuous Air Monitor preoperational checkr performed and system is operating.

6.2.3 Area Radiation Monitor operational cP.ecks performed and system is operating.

1

\\

i l

\\

\\

~

L

Sustect:

Proceeure No.

ACTIVATION OF THE TECHNICAL EPIP-26 Pete 4 of 6 Peges SUPPORT CENTER Aensson No, g

Cafe 11/2/82

(~

6.2.4 The following engineering disciplines are adequately represented:

6.2.4.1 Mechanical Engineering 6.2.4.2 Electrical Engineering 6.2.4.3 Radiological Engineering 6.2.5 Communications are established on the following:

6.2.5.1 Operations Line 6.2.5.2 Plant Status Update Line 6.2.5.3 Technical Functions Line 6.2.6 Shift schedule for the TSC organization is developed.

6.2.7 Personnel accountabili.ty is performed as directed by the ECC.

6.2.7.1 Muster list of personnel is submitted to the Site Protection Sergeant upon completion.

6.2.8 When the desired positions are adequately manned and functional, the Technical Support l

Center Coordinator should report the TSC 1

activated to the Emergency Director.

6.2.9 The function of the Technical Support Center is to provide a locat1on where engineering and operational teams can provide recommendations to the managerent concerning piant status during an emergency.

i' 6.2.10 Evacuation of the Technical Support Center wi?.1 be directed by the Emergency Director in the m

1 Susiert:

Proceewe No.

ACTIVATION OF THE TECHNICAL EPIP-26

% 5 8f 6

)

SUPPORT CENTER j

g,,,,,

3,,

1 g,,,11/2/82

(

event that the habitability requirements' for the center are not acceptable.

6.2.10.1 The Technical Support. Center Coordinator is resp.sible to notify the Emergency Director of center habitability conditions that could require evacuation.

i 6.2.10.2 All logs and communication documents (i.e., telefax sheets, communicator forms, etc.) and any supplies and equipment expected necessary will be collected before evacuating.

(

6.2.10.3 The Technical Support Center will re' locate to the Nearsite Emergency Operations Facility, re-establish communications with tne Emergency Control Center and provide support for the Technical Functions Croup.

6.2.10.3.1 If the Technical Support Center evacuates to the NEOF before the NEOF is activated, the staff

]

will assume the Technical Functions responsibilities / check-1.'st at the NEOF.

M

W PNe8we %

ACTIVATION OF THE TECHNICAL EPIP-26 Page 6 of 6 Pages SUPPORT CENTER Renmon No.

cete 11/2/82 7.0 RECOVERY When the Ersergency Director secures from emergency and allows the TSC to secure, the TSC Coordinator will ensure the following steps are taken:

7.1 All documentation is gathered and turned over to the Emergency Preparedness Department:

7.1.1 All completed communicator's message sheets 7.1.2 All completed procedura checklists 7.1.3 All facsimile machine transmitted documentation 7.2 Restow all emergency kits and lockers:

7.2.1 Record what supplies are needed to meet i

inventory requirement 7.2.2 Record what equipment malfunctioned 7.3 Return center to standby condition:

7.3.1 Restow tables and chairs, as required 7.3.2 Wipe all status boards clean 7.3.3 Refile all prints and procedures, as required 7.4 Report discrepancies to Emergency Preparedness Department:

7.4.1 Deliver documents from section 6.1 7.4.2 Report missing supplies and equipment discovered in performing section 6.2 l

7.4.3 Report missing prints and procedures discovered in performing section 6.3 7.5 Report TSC secured to the Emergency Director or his designes.

I 1

i l

~

Sussesr:

Presseure h ACTIVATION OF THE TECHNICAL EPIP-26 p,ge 1 of 1 pages SUPPORT CENTER tw mon A 1

Cete 11/2/82 Form EPIP 26-1 (1 page)

TECHNICAL SUPPORT CENTER ACTkVATION CHECKLIST _

1.0 TIME / INITIAIS

/

1.1 Facility accessible and properly equipped

/

1.2 Single entry point with frisking station established

/

1.3 Continuous Air Monitor preoperational checks performed and system is operating

/

1.4 Area Radiation Moniter opsrational checks performed and system is operating

/

1.5 Assigned engineering disciplines represented

/

1.6 Ceimusications established

/

1.6.1 Operations line

/

1.6.2 Plant Status Update line

'/

1.6.3 Technical Functions line

/

1.7 Report TSC activated to the Faergency Director

/

1.8 Accountability completed, if required i

/

1.9 Facility deactivated by order of Emergency I

Director

/

1.9.1 Laergency kits / lockers restowed

/

1.9.2 Documentation collected l

/

1.9.3 TSC returnal to standby condition

/

1.9.4 Documents, records and reports delivered to Emergency Preparedness Department l

NAME:

Technical Support Center Coordinator Time Da te

~_

f_

.3.

_.. u...

suspen Prosecure Me.

ACTIVATION OF THE TECHNICAL EPIP-26 Peen 1 of 1 pages SUPPORT CENTER h*"

1 Cen 11/2/82 EPIP-26 Figure 1 Directions:

Enter thru the Main Gate Processing Center, proceed west on the Ac, cess Road or enter thru the North Gate Processing Center, proceed south and follow the Access Road to the Machine Shop adjacent to 'the Turbine Building. Enter the center door and follow the hallway to the end.

The Technical Support Center is located on the right at the end of the hallway.

e 4E Lw

__ 't.m9 l

'2"~ N 4-Q

\\

6. t h i

_ e 8ws gegin Y

lese. caw l 3

s em

[

l ]

~

rt n"

.i

'~-

T

  1. 3%'!"la!3

-e-1 T

nl w

w o

-w.

(

me==.

Si 84hA48Pe6 8

nas i

-i m..

m l

o man 1~

N --lb.

h No.

ACTIVATION OF THE TECHNICAL EPIP-26 PW48 i W i SUPPORT CENTER Aenesen Ne=

OMe 1

11/2/82 I

FIGURE 2

~ ~

sprour assum A

FEXWEJ05 h =4-*4an=,

8 0 y

T 1 mme 11am

'2 stathus Sainmity/Acammt.1.ine b

3 Pla t status t%sisto 11am

,A 4 'T"""*i=" 11am 1

5 muryonor DLematur's 11am 20 5 1edadmL Ptsiotham 11am i

2 7 stato mit Line As **4*im4=

as ter4fimkim g

WrXI 3

F ErBWE Upsal O Osman Qumite at Line

")

As Ik2ENW 4

m 12 3: wfim*W 3

6 9 IEC Emuguncy **4*i=*i-11am 10 IRC Emelth Playsice ler.*4Nmeian gy, 11am g,,

3 13 ' 11 20 auttum talar mn= est e

10 12 Buri-=1 Amoernw lian 13 m alaysan Iggr, g

kg staumscan U

a tatda Q Emmsgancy Incker 7

a Aset a Flast 5th Bompi/

g C QuqasterWar alask e m w l-D Team status Rimed 3 Wmear logy:

C, 9

g,g gag s

,3,,,,,,,,yt,,,,,31,

I G 2h Filing Chtdnet' ~W 11*

E 5 andtuhale

[.

,")T 1 24 4mur C1cck i

J aarHalagim1 h gtetRW BoEEd -

l K cWia sep L mamate audio system M NS-3 N Felding Partit.ica FN o ammegamer rockar P Friaking * =*i m i

l e

9

~ ~ "

P-27

,Page i Of 6

^

(

Jersey Central 02/24/81 (01/27/a3) 01/30/83 i

Power & L,ght Company Revision No.

Date 1

11/02/82 j

Subject ACTIVATION OF THE OPERATIONS SUPPOKI CENTER Authonzed By Director-Station Operations a

ApprovaUConcurrence jgs2 3

Project Oyster Creek Nuclear Generating Station LIST OF EFFECTIVE PAGES D/.TE REVISION NUMBER 1

11/2/82 1

2 11/2/82 1

l 3

11/2/82 1

4 11/2/82 1

5 11/2/82 1

6 11/2/82 1

AT'"ACHMENTS DATE REVISION NtHBER Form EPIP 27-1 (1 page) 11/2/82 1

EPIP 27, Figure 1 (1 page) 11/2/82 1

EPIP 27, Figure 2 (1 page) 11/2/82 1

NON-CONTROL.5 This Docuraent Will Not Be Kept Up To Date k'

DCC Oyster Creek

hoper:

Proceeure Ne, W

ACTIVATION OF THE OPERATIONS EPIP-27 2

6 SUPP0lt CENTER han N&

Qate 11/2/82 1

[

~

1.0 PURPOSE This procedure describes the activation, initial operations and recovery of the Operations Support Center.

2.0 REFERENCES

2.1 EP IP-2 Unusual Event 2.2 EPIP-3 Alert 2.3 EP IP-4 Site Emergency 2.4 EPIP-5 General Emergency 3.0 RESPONSIBILITIES 3.1 The Emergency Director is responsible to evaluate conditions and determine the need to activate the Operations Support Center.

(

3.2 Tue Operations Support Center Coordinator is responsible for the efficient activation of the Operations Support Center and to carry out the requirements of this procedure.

4.0 PREREQUISITES 4.1 OSC activation may be initiated by any of the following:

4.1.1 Unusual Event 4.1.2 Alert 4.1.3 Site Emergency 4.1.4 General Emergency 4.1.5 By direction of the Laergency Director 5.0 PRECAUTIONS 5.1 The following precautions will. be observed:

5.1.1 Use proper respiratory protective devices as

(

directed by Radiological Controls

~

.m

_,e.

= =.

~

~~

s eper:

Preseawe No.

ACTIVATION OF THE OPERATIONS EPIP-27 p,,, 3,,

p,,

6 SUPPORT CENTER Aewsion No.

1 Cete 11/2/82 5.1.2 Usr. proper dosimetry as" directed by Radiological controls 5.1.3 Maintain radiation / airborne radioactivity level surveillance during emergency operations 5.1.4 Proper frisking techniques will be followed by all personnel prior to entering the OSC 6.0 REQUIREMENTS NOTE:

The Operations Support Center is located on the second floor of the North Maintenance Building (Attachment 1) and directed from the Maintenance Conference Room (Attachment 2).

6.1 Upon notification that the Operations Support Center is being activated, the Oyster Creek Nuc' lear Generating Station Security Department will ensure its accessibility and security.

6.2 The OSC Coordinator, using form 27-1, will ensure completion of the following:

6.2.1 Establish two points of entry with frisking stations within the maintenance building.

6.2.2 Continuous Air Monitor preoperational checks performed and system is operating.

6.2.3 Area Radiation Movi;or operational checks performed and dystem is operacing.

6.2.4 The following functional groups are established and ready to respond as directed from the Emergency Control Center:

6.2.4.1 Damage Control response 6

O

w.

Procoewe m ACTIVATION OF THE OPERATIONS EPIP-27 page 4 of 6 pege.

SUPPORT CENTER beson %

1 Cote 11/2/82 l

l 6.2.4.2 Radiological Control response s

6.2.4.3 Chemistry response 6.2.4.4 Medical response 6.2.4.5 Emergency teams assembled for. dispatch 6.2.5 Communications are established on the following:

6.2.5.1 Operations line 6.2.5.2 Plant Status Update line 6.2.5.3 Radiological line 6.2.6 A shif t schedule for the OSC organization is developed.

6.2.7 Personnel accountability is performed as directed by the ECC.

6.2.7.1 Muster list of personnel is submitted to the Site Protection Sergeant upon completion.

6.3 When the desired positions are adequately manned and functional, the Operations Support Center Coordinator should i

report the OSC activated to the Operations Coordinator.

l 6.4 The function of the Operations Support Center is to provide a location from which response teams may be assembled, dispatched and directed to support Emergency Response.

6.5 Evacuation of the Operations Support Center w;11 be directed by the Emergency Director in the event that the habitability requirements for the center are not acceptable.

6.5.1 The Operations Support Center Coordinator is

\\

responsible to notify the Emcrgency Director of

~

M, h%

)

ACTIVATION OF THE OPERATIONS p?P-27 M

fi D

'I SUPPOKr CENTER woon g

get, 1

11/2/82 center habitability conditions that could require evacuation.

1 6.5.2 Collect all logs and communications documents (i.e., telefax sheets, communicators' forms, etc.)

and any supplies and equipment expected to be

)

needed.

6.5.3 Proceed to the Technical Support Center area, 1

re-establish communication with tha Emergency i

Control Center &nd provide support as directed.

l 7.0 RECOVERY 1

When the Emergency Director secures from emergency and allows the OSC to secure, the OSC Coordinator will ensure tha following steps

(

are taken:

7.1 All documentation is assembled and deliverad to the Laergency Preparedness Department:

7.1.1 All completed communicators' message sheete

)

l 7.1.2 All completed procedure checklists l

7.1.3 All facsimile machine transmitted documentation 7.2 Restow all emergency kits and lockers:

7.2.1 Record what supplies are needed to meet inventory requirements 7.2.2 Record what equipment malfunctioned 7.3 Return center to standby condition:

7.3.1 T.estow tables and chairs, as required 7.3.2 Wipe all status boards clean i

\\

7.3.3 Refile all prints and procedures, as required

. eso..

e.,

em

Estear:

Nw %

d ACTIVATION OF THE OPERATIONS m w_97 A

A SUPPORT CENTER benen %

Qete 1

11/2/82 7.4 Perform the following and report discrepancies to the Supervisor, aergency Preparedness:

7.4.1 Deliver documents from section 6.1 7.4.2 Report missing supplies and equipment-discovered in performing section 7.2 7.4.3 Report missing prints and procedures discovered in performing section 7.3 7./

Zaport OSC secured to the Operations Coordinator.

(

e e

n om 9

Espsz.

Presseere m ACTIVATION OF THE OPERATIONS EPIP-27 page 1 of 1 posse SUPPORT CENTER h an %

1 Oste 11/2/82

+-

(

t

~

Form EPIP 27-1 j

1.0 OPERATIONS SUPPORT CENTER C00RDINAT0gS CRECKLIsr TIME / INITIALS

/

1.1 Facility a ccessible and properly equipp.ed.

1.2 Two entry points with frisking stations

/

established 1.3 Continuous Air Monitor preoperational checks

/

performsd and system is operating.

1.4 Area Radiation Monitor operational checks

/

performed and system is operating.

1.5 Assigned groups are functional.

/

1.5.1 Damage control

/

1.5.2 Radiological Controls

/

1.5.3 Ched stry

/

1.5.4 Medical

/

1.5.5 Emergency Teams 1.6 Communications established

/

1.6.1 Operations Line

/

1.6.2 Plant Status Update Line

/

1.6.3 Radiological Line

/

1.7 Report OSC activated to the Operations Coordinator.

/

1.8 Accountability completed, if required.

l I

/

1.9 Facility deactivated by order of Emergency Director.

/

1.9.1 Emergency Kits / Lockers restowed

/

1.9.2 Documentation collected

/

1.9.3 OSC returned to standby condition

(

/

1.9.4 Documents, records and reports delivered to Emergency Prepareduss Department l

NAME:

g Operations Support Center Coordinator TIME DATE

,s

..-. -~~ -

%spose:

Presseure Me, ACTIVATION OF THE OPERATIONS -

EPIP-27

% 1 W 1 **

SUPPORT CENTER Assessee Me.

Cate 1

11/2/82

~

FIGURE 1 OPERATIONS SUPPORT CENTER DIRECTIONS:

Enter f.he Main Gate and,jroceed west then acr*.h on the Access road to the North Maintenance Pullding or anter the North Gate and cross the

' i

.)

Access road to the North Maintenance Building. Enter the North Maintenance

!l Building irf waf of the norttvast stairwell, then preceed up the stairs.

l The entrance to the Operations support Center is at the top of the stairs

)

on the second floor.

.I

, g~ T,,

ws) gg

_ a

At"'

Q /

f :MC

\\

I

> ".).

P romuq = ] s" 3

/

i AB.

).l O

E.,,

-/=

s,,

g I

massee - - _ - -

em i

e amen" 6

p\\

= = -

y

/-

ll LN_ '

C"l.

L

.t

,6,[d 4 gl menevee t

n N

'l

-== g 4 est,== _ L.w; r

t m.

._ nL w-

[

s!

lw i,.-

i t

s

,w 1

%.J

}

l m.s.=

j-M C

' (g O

-=.*

) s,

=

i

L I _ +.

.m e

Suspec Messeure Me.

ACTIVATION OF THE OPERATION'S EPIP-27

% 1 # 1 SUPPORT CENTER beh Om 1

11/2/82 FIGURE 2 OFDutrIONS SUPPORT CErfER Entrance Jr 2,3,A gC j

y

, y L

Dl 3

g PIELD RESFCItSE Gr; -- --

~~

  • g 6 p,

A.Telefax' FaM a=t S

AND S MIDBY 7

Clif2E, 4

hs B.ARDt C. Coat Back 1

D.Teaun Status Board E. Clear Flexiglaes 10 g.

E F. File Cabinet C. Support Status Bd.

I1 4 a7 ti. Clock (24 hr)

I.CAN

(

J. Emergency Lockers

. A K.Friaker Station Showers IIashroca ColecitICATICIIS:

1.Oparations line

2. Plant Status line
3. security /Acetbly it

-\\

O M ces 4.Ehergency Director 11,,

5.madiologicaA line

6. Environmental lire 7.Conventioral paone
8. Plant Page Phores 9.h Infb Line i

10.MN Line Bridgqi i

O y

e

-. -